Bedienungsanleitung - Driescher • Wegberg

image

Contents

1. 402 705 253 5 266 i HEBEL E a o 1 o i LESS L i N E amp 57 5 at bei Linksantrieb H for left side drive 40 B dg zul ssige Anschlu breite 50 mm p 240 Permissible connection width 50mm p 240 B D M P_ xX Y Bei Rechtsantrieb Hilfslager notwendig bei Ma Y gt 150 mm Bei Linksantrieb Hilfslager notwendig bei Ma X gt 150 mm Hilfslager Typ HLBF H 40 140 mm verstellbar in case of right side drive auxiliary bearing needed when dimension Y gt 150 mm in case of left side drive auxiliary bearing needed when dimension X 2 150 mm auxiliary bearing type HLBF H 40 140mm adjustable gedrangte Bauart Compact design Mechanische Verriegelung Mechanical interlock Antriebswelle Schaltwinkel 95 Typ F 110 Typ EA Betatigungsseite rechts ye Actuator shaft actuating angle 95 Type F 110 Type EA Actuating side right Hilfslagerbock f r Antriebsseite rechts Auxiliary bearing block for drive side right Hilfslagerbock f r Antriebsseite rechts Auxiliary bearing block for right side drive Antriebswelle Schaltwinkel 95 Bet tigungsseite rechts Actuator shaft actuating angle 95 Actuating side right DIN Schalter DIN
2. Das Ein und Ausschalten des Lasttrennschalters bzw Erdungsschalters erfolgt Uber einen Schalt hebel Die eingebaute Federsprung bzw Kraftspeicher Schaltvorrichtung sorgt f r sicheres Ein und Ausschalten unabh ngig von der Bedie nungsgeschwindigkeit Bei der ersten Probeschaltung der Schalter und Erder ist besonders wichtig da bei der Ein schaltbewegung der Schalter oder Erder ein schaltet Gleichzeitig ist darauf zu achten da die Anschl ge der Antriebsscheiben 1 in der nie renf rmigen Aussparung am Seitenrahmen die jeweiligen Endstellungen erreichen Der Drehwinkel f r die Schaltbewegung der Antriebswelle betr gt min 95 bei Schaltger ten vom Typ F und 110 bei Schaltger ten vom Typ EA Wird das Schaltger t ber Gest ngeantriebe o bet tigt so beachten Sie die besonderen Angaben und Einstellhinweise im Anhang B Checking the Mechanical Function After the drive is assembled the switch should be test actuated several times The switch disconnector or earthing switch is turned ON and OFF via a switching lever The built in spring or stored energy device ensures reliable activation and deactivation regardless of the operating speed During the initial test actuation of switch disconnector or earthing switch it is especially important that the switches turn ON At the same time make certain that the catches of the drive discs 1 reach the pertinent end positions in the
3. Sonder Betriebsbedingungen Nach VDE 0670 Teil 1000 k nnen von den nor malen Betriebsbedingungen abweichende Be triebsbedingungen zwischen Hersteller und Be treiber vereinbart werden Zu jeder Sonder Betriebsbedingung mu der Hersteller vorher befragt werden Hinweis zu etwaigen klimatischen Sonder Betriebsbedingungen Beim Betrieb von Schaltger ten in Gebieten mit hoher Luftfeuchte und oder starken kurzzeitigen Temperaturschwankungen besteht die Gefahr von h ufigen Tauniederschl gen Zur Vermeidung unzul ssiger Kondensationserscheinungen und sich dadurch m glicherweise ergebender Korrosi on sind in Absprache mit dem Hersteller Gegen ma nahmen z B elektrische Heizung zu ergrei fen Haftungsbeschr nkungen Alle in dieser Montage und Betriebsanleitung enthaltenen technischen Informationen Daten und Hinweise f r die Installation Bedienung und Wartung der Mittelspannungs Schaltger te ent sprechen dem Stand der Drucklegung und erfol gen unter Ber cksichtigung unserer bisherigen Erfahrungen und Erkenntnisse nach bestem Wis sen F r etwaige Fehler oder Unterlassungen haften wir unter Ausschlu weiterer Anspr che im Rah men der im Hauptvertrag eingegangenen Ge w hrleistungsverpflichtungen Anspr che auf Schadensersatz gleich aus welchem Rechts grund derartige Anspr che hergeleitet werden sind ausgeschlossen soweit sie nicht auf Vorsatz oder grober Fahrl ssigkeit beruhen Special Operating Cond
4. bernahme des Mittelspannungs Schaltger tes mit allen Einzelheiten der Bedienung vertraut sein Operation Putting into Service e Comply with safety regulations page 10 and accident prevention regulations e Check Assembly Work Check whether all assembly work has be en done properly e Check mechanical functions see page 22 E The high voltage is not to be turned ON e Connect the auxiliary and control voltage e Terminate all protective measures taken e g short circuit and grounding connections in such a manner that no danger results for per sonnel or material goods Instructing Operators Hand the Operation and Assembly Instructions out to the operator qualified electrical technician be fore putting the switch into service Before he or she takes over the medium voltage switch the operator must be familiar with all details of operation 26 LDTM DRIESCHER e WEGBERG Schalthandlungen Schalten des Lasttrennschalters Typ F Das Ein und Ausschalten des Lasttrennschalters erfolgt Uber einen Schalthebel Die eingebaute Federsprung Schaltvorrichtung sorgt f r sicheres Ein und Ausschalten unabh ngig von der Bedie nungsgeschwindigkeit Typ SEA Der Lasttrennschalter mit Freiausl sung Typ S EA verf gt ber einen Federkraftspeicher der mit dem Einschalten gespannt wird Die Freiausl sung erfolgt Uber HH Sicherungen mit Schlagstift der Klas se mittel entsprechend
5. 1a Auxiliary bearing block 8 for left side drive 15 1143 36 LDTM 24 630 SF SEA E 531 328 Ausl sevorrichtung nur bei Typ SEA Tripping device only for type SEA Hilfsblech optional Auxiliary plate optional 705 Mechanische Verriegelung Mechanical interlock Betatigungsseite rechts Actuator shaft actuating angle 95 Type 110 Type EA dipl dA Actuating side right Wy Hilfslagerbock f r if Antriebsseite rechts tE HS bei Linksantrieb for left side drivg zul ssige Anschlu breite 50mm p 240 Permissible connection width 50mm p 240 Lob 40 4 Auxiliary bearing block for drive side right Hilfslagerbock f r Antriebsseite rechts Auxiliary bearing block for drive side right Antriebswelle Schaltwinkel 95 Bet tigungsseite rechts B Y Antriebswelle Schaltwinkel 95 Typ F 110 Typ EA he a ER Actuator shaft actuating angle 95 Bei Rechtsantrieb Hilfslager notwendig bei Ma Y gt 150 mm Bei Linksantrieb Hilfslager notwendig bei Ma X 2150 mm Hilfslager Typ HLBF H 40 140 mm verstellbar in case of right side drive auxiliary bearing needed when dimension Y gt 150 mm in case of left side drive auxiliary bearing needed when dimension X 15
6. 624 102 210 150 150 14 LDTM DRIESCHER e WEGBERG LDTM 12 630 SF SEA E gepr fte AnschluBzone 451 p 145 248 Tested connection zone Pa p 145 2 2 14 Ausl sevorrichtung nur bei Typ SEA a Tripping device only 9 for type SEA das angegebene Ma ist einzuhalten f r Sicherungseinsatz 2 i nach VDE 0670 Teil 4 Bauform q Hilfsblecn optional Tr n The specified dimension auxiliary plate optional must be adhered to for fuse link per t Hs IEC 60282 1 type HE E 1 ET 4 7 2 g fia 7 gepr fte AnschluBzone p 145 Tested connection zone ive p 145 322 515 Mechanische Verriegelung Mechanical interlock Antriebswelle Schaltwinkel 95 Typ F I E 110 Typ EA w Bet tigungsseite rechts 3 Hilfslagerbock f r i Actuator shaft actuating angle 95 Type F Antriebsseite links L 110 Type EA Actuating side right Auxiliary bearing block for left side drive 4 fe e e a i 5 y i i i i 575 bei Linksantrieb for left side drive o a De o a A o T rg 3 E i a t Pr aa A i o 8 Ae Hilfslagerbock f r Antriebsseite links E SS Bet tigungsseite rechts Antriebswelle Schaltwinkel 95 Auxiliary bearing block rome i
7. Anschlie einschalten durch HH Siche Rend ist der rungseins tze mit Transformator Schlagstift oder Lasttrenn durch Magnet schalter ein ausl ser schaltbereit HH Siche rungseins tze tauschen Pr fen ob Spannung am Magnetausl ser ansteht ggf Ursache ermit teln 2 Keine Freiaus HH Sicherungs HH Siche l sung des einsatz ist falsch rungseinsatz so Transformator in die Halterung in die Halte Lasttrenn eingesetzt rung einsetzen schalters Typ da der SEA beim Schlagstift nach Ansprechen oben zeigt des HH Siche rungseinsalzes HH Sicherungs HH Siche ausl sekraft entspricht nicht der Klasse mit tel nach VDE 0670 Teil 4 rungseins tze mit mindestens 50 N Ausl se kraft und 20 mm Min desthub des Schlagstiftes einsetzen No Problem Possible cau Remedy se 1 Transformer Trip free relea Move the actua switch se ofthe tor shaft down disconnector transformer The transformer won t turn ON switch switch disconnector disconnector is caused by HV then ready to be H R C fuse turned ON with striker pin or by magnetic Exchange HV trip H R C fuse Check whether voltage present at magnetic trip if so determine cause 2 No trip free HV H R C fuse Insert HV H R C release of was incorrectly fuse into the transformer inserted into carrier in such a switch the carrier manner that the disconnector striker pin is at type SEA wh
8. F r diese Druckschrift behalten wir uns alle Rechte vor MiB br uchliche Verwendung wie insbesondere Vervielf ltigung und Weitergabe an Dritte ist auch auszugsweise nicht gestattet Angaben und Abbildungen unverbindlich nderun gen vorbehalten We reserve all rights for this publication Misuse especially duplication and transfer to third parties is prohibited even in case of excepts Text and illustrations are not binding We reserve the right to make revisions DRIESCHER e WEGBERG 2000 DRIESCHER e WEGBERG 2000 LDTM 3 DRIESCHER e WEGBERG Allgemeines Bestimmungsgem e Verwendung Die DRIESCHER LDTM Schaltgerate sind typge pr fte Wechselstrom Lasttrennschalter bzw Erdungsschalter f r Innenraumanwendung bei Spannungen von 12 24 kV Der Mehrzwecklasttrennschalter ist zum Schalten von Str men bis 630 A und zur Bildung einer Trennstrecke gem VDE 0105 geeignet Normen und Vorschriften Vorschrift der Berufsgenossenschaft BGV A1 VBG 1 BGV A2 VBG 4 Allgemeine Vorschriften Elektrische Anlagen und Betriebsmittel Normen DIN VDE 0101 Starkstromanlagen mit Nenn wechselspannungen Uber 1kV DIN VDE 0105 Betrieb von elektrischen Anla gen VDE 0670 Teil 2 Wechselstromtrennschalter und Erdungsschalter VDE 0670 Teil 301 Hochspannungs Lastschalter VDE 0670 Teil 303 Hochspannungs Lastschalter Sicherungs Kombination VDE 0670 Teil 1000 Gemeinsame Bestimmungen f r Hochspan
9. Solely the Germany text which can be made available on request shall prevail LDTM DRIESCHER e WEGBERG Gewahrleistung Diese Montage und Betriebsanleitung enthalt alle erforderlichen Hinweise und ist vor Inbetriebnah me der Mittelspannungs Schaltger te sorgfaltig durchzulesen F r Sch den und Betriebsst rungen die sich aus der Nichtbeachtung der Montage und Betriebs anleitung ergeben Ubernehmen wir keine Haf tung Gew hrleistungsanspr che sind sofort nach der Feststellung des Mangels unter Angabe der Auf tragsnummer schriftlich anzumelden Die Gewahrleistung erlischt bei unsachgem Rer Behandlung nicht bestimmungsgem er Verwendung unzulassigen Betriebsmitteln fehlerhafter Aufstellung falschem oder nicht fachgem em Anschlu der Mittelspannungskabel bzw der Hilfs Steuerleitungen Driescher HH Sicherungen Zubeh r und Er satzteile sind speziell konstruiert und in aufwendi gen Testreihen erprobt worden Wir weisen ausdr cklich darauf hin da nicht vom Hersteller gelieferte Ersatzteile sowie die nicht vom Hersteller empfohlenen Zubeh rteile auch nicht vom Hersteller freigegeben sind Der Einbau und die Verwendung von Fremdprodukten kann unter Umst nden konstruktiv vorgegebene Eigen schaften der Produkte negativ ver ndern und die Sicherheit f r Personen Schaltanlage oder ande re Sachwerte beeintr chtigen Vor Einbau von Fremdprodukten ist die schriftliche Genehm
10. 1 2 3 L L L co1 pp Fa Erox Rita PME 271M 330nF 250V AC 630V DC AC 110 230 V Y1 E 24vDC o 100 ED S01 Ji s X1 j1 2 3 eh o L L1 N 30 LDTM DRIESCHER e WEGBERG Anhang B Antrieb VSAK Bet tigung der Schaltger te mit dem Antrieb Typ VSAK Die am h ufigsten vorkommenden Antriebslagen sind in den Anordnungen 1 und 2 dargestellt Annex B Drive VSAK Actuating the Switches with Drive Type VSAK The drive positions that occur most frequently are illustrated in setups 1 and 2 EIN G N a DS Anordnung 1 N EIN 2 A Als EN N amp Lis O p I a AUS EIN ENG A MA i 2 OE AUS AUS Anordnung 2 SS EIN AUS Anordnung 1 Setup 1 Setup 1 Gest nge und Schalterkurbel sollten in EIN Stellung einen spitzen Winkel bilden Der Winkel der im Radius verstellbaren An triebskurbel sollte m glichst stumpf sein ohne jedoch die Totpunktstellung zu erreichen Anordnung 2 Gest nge und Schalterkurbel sollten in EIN Stellung einen stumpfen an der Antriebskurbel einen spitzen Winkel bilden Auch hier darf in kei ner Schalterstellung die Totpunktstellung erreicht werden Hinweis Alle Lasttrennschalter und Erder k nnen wahlweise mit Hand oder Motorantrieben ausge r stet werden Bei Bedarf k nnen die Unterlagen angefordert werden In the ON position linkage and switch crank should form an sharp angle The
11. BETRIEB UND WARTUNG 10 ASSEMBLY AND MAINTENANCE 10 TECHNISCHE DATEN uuueeensnseseneneennennee 11 TECHNICAL DATA n 11 BEMESSUNGSGROREN 11 RATED VALUES aannannnnennnennennnn 11 ABMESSUNGEN LDTM 12 24 kV 11 DIMENSIONS OF LDTM 12 24 kV 11 MONTAGE 22uusua2nunnannnunnannnnnnnnnnnnnnnnnnnnnnnnnnn 18 ASSEMBLY eee 18 ABLADEN UND TRANSPORTIEREN 18 UNLOADING AND TRANSPORTING 18 MONTAGE DES MITTELSPANNUNGS MOUNTING THE MEDIUM VOLTAGE LASTTRENNSCHALTERS tate 19 SWITCH DISCONNECTOR 19 ANDERUNG DER ANTRIEBSSEITE 20 CHANGING THE DRIVE SIDE 20 VORBEREITEN VON LASTTRENNSCHALTER PREPARING SWITCH DISCONNECTOR TYP S BA 2 222282 ise 21 TYPE S EA ann 21 MECHANISCHE FUNKTIONEN PRUFEN 22 CHECKING THE MECHANICAL FUNCTION 22 BETRIEB nua aa 25 OPERATION eee 25 INBETRIEBNAHME ee 25 PUTTING INTO SERVICE 25 SCHALTHANDLUNGEN 26 SWITCHING OPERATIONS 26 INSTANDHALTUNG ren 27 MAINTENANCE 27 WARTUNG esses 27 MAINTENANCE nn 27 FEHLERBEHEBUNG u222uuu20000nnnnnnnannnnnn 28 RESOLVING PROBLEMS 28 ANHANG A MAGNETAUSLOSER 29 ANNEX A TRIP COlL ese 29 ANHANG B ANTRIEB VSAK 0 30 ANNEX B DRIVE VASK 30
12. H I N for left side drive a He ae Actuator shaft actuating angle 95 Actuating side right 40 x B y zul ssige Anschlu breite 50mm p 145 Permissible connection width 50mm p 145 Bei Rechtsantrieb Hilfslager notwendig bei Ma Y gt 150 mm Bei Linksantrieb Hilfslager notwendig bei Ma X 2 150 mm Hilfslager Typ HLBF H 40 140 mm verstellbar in case of right side drive auxiliary bearing needed when dimension Y gt 150 mm in case of left side drive auxiliary bearing needed when dimension X 2 150 mm auxiliary bearing type HLBF H 40 140mm adjustable DIN Schalter DIN switch Ma e Dimensions Typ Type gedr ngte Bauart Compact design B D M P x Y B D M P x LDTM 12 630 414 438 74 145 150 150 600 624 102 210 150 150 LDTM 15 DRIESCHER e WEGBERG SF E SEA E gepr fte Anschlu zone p 240 Tested connection zone p 240 q 19 q gepr fte Anschlu zone p 240 Tested connection zone p 240 Hilfslagerbock f r Antriebsseite links Auxiliary bearing block for left side drive Hilfslagerbock fiir Antriebsseite links Auxiliary bearing block for left side drive Ma e Dimensions Typ Type 15 555 36 350 LDTM 24 630 F EA E 328 414 e
13. accident prevention regulations Unload and transport medium voltage switches with fork lift Transport B To avoid damage NEVER use the arcing chamber or the isolating blades for a hand hold or as pickup points for transport devi ces Pick up and transport the switches by the base frame or by the crosshead During all transport movements secure the medium voltage swit ches to prevent it from tipping over Make certain that the weight is evenly distri buted Do not set the switches down on the arcing chambers or stack them on or in one another L schkammer Traverse Crosshead Grundrahmen Base frame Hauptmesser Main blade After unloading e Check medium voltage switches and accesso ries for shipping damage e Check the accessories against the delivery note to make certain they are complete Document shipping damage and immediately notify the shipping agent the insurance company and DRIESCHER LDTM 19 DRIESCHER e WEGBERG Montage des Lasttrennschalters Mittelspannungs E Beachten Sie da das Schaltger t Mounting the Medium Voltage Switch Disconnecor E Note that the switches is not to be swit waagerecht nicht geschaltet werden darf Das Schaltger t ist nur fur senkrechte Ger st und Wandmontage geeignet Andere Einbaupositionen m ssen der Firma DRIESCHER mitgeteilt werden da zus tzliche Anbauten erforderlich sind Um die mechanische Funktion der Sc
14. after cleaning must be corrected The manufacturer is to be commissioned to do so The contact slide pathes are to be treated with solid paraffin only Under no circumstances are customary lubricants grease or oils to be used In the event of sluggishness in the mechanical sequence of movements the bearings of the drive mechanism should be treated with a spray oil capable of creeping Spray oils have the advanta ge that the lubricant actually reaches the area cau sing sluggishness Regardless of the type of switch used the owner should make certain that the station compartments are clean and dry After the maintenance several test actuations are to be conducted before putting the switches into service 28 LDTM DRIESCHER e WEGBERG Fehlerbehebung Beachten Sie bei der Fehlerbehebung alle in der Bedienungsanleitung aufgef hrten Sicherheitshin weise Die Fehlerbehebung d rfen nur Elektrofachkr fte gem Definition in DIN VDE 0105 durchf hren Resolving Problems Whenever resolving problems comply with all the safety instructions in the Operating Instructions Problems are only to be resolved by qualified elec trical technicians as per definition in EN5010 1 Nr Fehler Mogliche Ursa Abhilfe che 1 Transformator Freiausl sung Die Antriebs Lasttrenn des Transforma welle nach schalter l t tor Lasttrenn unten bet ti sich nicht schalters erfolgte gen
15. des Hilfswerkzeug das Ende der Ausschaltfeder in die Bohrung 5 der unte ren Schaltertraverse 6 Entfernen Sie das Hilfswerkzeug 9 A Es darf nicht an den Trennmessern 7 und Nacheilmessern 8 gezogen werden Gefahr von Verletzungen 2 3 4 Erst nach erfolgter Befestigung darf das Gerat geschaltet werden siehe Mechanische Funktion pr fen Preparing Switch disconnector Type S EA Switches of the type S EA with release energy storing device are delivered with the release spring disconnected Installation of release spring Remove the auxiliary equipment provided for the transport 2 and 3 Put isolating blades 7 manually in OFF position by carrying out a pulling movement of the switch rods 4 Fasten the auxiliary tool 9 with the hook onto the end of the release spring 1 Move the end of the release spring into bore hole 5 at bottom cross beam of the switch 6 and this by using a big screw driver and hand ling through the eye of the auxiliary tool Remvove the auxiliary tool A Do not pull on the isolating blades 7 or the lagging blades 8 risk of injury p Li Do not switch until fastening is complete see Checking the Mechanical Function 22 LDTM DRIESCHER e WEGBERG Mechanische Funktion prufen Nach der Antriebsmontage sollte der Schalter eini ge Male probegeschaltet werden
16. in EN 50110 1 are permitted to put into ser vice work on or operate medium voltage swit ches in each case in compliance with the perti nent valid IEC regulations 5 safety rules as per the EN 50110 1 safety regulations accident prevention regulations Operating and accessory parts must always be available for and accessible to the qualified elec trical technician and must be in proper condition They are not to exhibit any damage Replace damaged operating and accessory parts by tested or approved DRIESCHER parts Responsibilities and operating sequences for ope ration and maintenance must be regulated and must be adhered to Qualified electrical technicians According to EN 50110 1 a qualified electrical technician is a person who can evaluate the work assigned to him or her and can recognize possi ble damages on the basis of his or her technical training know how and experience D The qualified electrical technician must be authorized by the person responsible for the safety of the switches to perform the work and activities required 10 LDTM DRIESCHER e WEGBERG Funf Sicherheitsregeln 1 Freischalten Mittelspannungs Schaltger te an denen ge arbeitet wird beidseitig freischalten 2 Gegen Wiedereinschalten sichern Hinweisschilder an freigeschalteten Schaltge raten anbringen mit dem Vermerk Was wurde freigeschaltet Grund der Freischaltung Name der Person die freigesc
17. placed under tension when you tighten the fa stening screws It is imperative that any une venness be compensated for by placing shims in the area of the fastening holes The switches must be fastened with M12 fa stening screws Switch type Number of M12 screws see pp 12 17 F EA F E EA E SF SEA SF E SEA E CO D O E When installing drives take particular care to ensure that the switch actuating shaft does not finish the switching operation until itis min 95 in case of switches type F and 110 in case of switches type EA away from the starting position It is also important that the contact connectors are not warped or strained when connecting the conductors counterhold with 2nd wrench In the case of actuator shafts with Y gt 150 mm in case of right side drive or X gt 150 mm in case of left side drive use an auxiliary bea ring block type HLBF Art No 0067319 Make the required earth connection to the switch frame 20 LDTM DRIESCHER e WEGBERG Nachtr gliche nderung der An triebsseite Von Rechts auf Links Die Spannstifte 8 5 1 der Antriebsscheibe rechts 2 austreiben die innenliegende Welle 20 3 nach links schieben und Spannstifte wieder eintreiben Antriebsstutzen links 4 und Spann stifte 2 8 5 optional Ma x beachten mit der Antriebswelle verstiften E Bei Linksantrieb immer Hilfslager verwen den Op
18. properties of products and may impair the safety of persons switches or other material resources The written approval of the manufacturer is required before installing third party products The manufacturer assumes absolutely no liability for damage resulting from the unapproved use of third party products or arbitrary changes or con versions of our products or accessories Duration of Warranty The warranty is valid for 12 months starting with delivery LDTM DRIESCHER e WEGBERG Kundendienst F r s mtliche technische Ausk nfte ber DRIESCHER Produkte und deren systemtechni sche Anwendungen steht Ihnen unser Kunden dienst zur Verf gung Treten Schwierigkeiten an unseren Produkten auf wenden Sie sich bitte an die zust ndige Vertre tung oder an das Herstellerwerk Geben Sie bitte bei R ckfragen oder Ersatzteilbe stellungen folgende auf dem Typenschild ange gebene Daten an Schaltgeratetyp Auftragsnummer Fabrikationsnummer Baujahr Bemessungsspannung und Bemessungs strom Durch Angabe dieser Daten ist gew hrleistet da Ihnen die richtigen Informationen oder die ben tigten Ersatzteile zugehen Fritz Driescher KG Spezialfabrik f r Elektrizit tswerksbedarf GmbH amp Co Postfach 1193 D 41837 Wegberg Industriestra e 2 D 41844 Wegberg Telefon 02434 81 1 Telefax 02434 81446 www driescher wegberg de e mail info driescher wegberg de Technische Anderungen im R
19. 0 mm auxiliary bearing type HLBF H 40 140mm adjustable Actuating side right Ma e Dimensions Typ Type gedr ngte Bauart Compact design B D M P x Y B D M P DIN Schalter DIN switch x LDTM 24 630 SF E SEA E 604 628 74 240 190 190 750 774 112 275 190 190 18 LDTM DRIESCHER e WEGBERG Montage Abladen und Transportieren Sicherheitshinweise Seite 10 und Unfallver h tungsvorschriften beachten Mittelspannungs Schaltger te mit Hubstapler abladen und transportieren Transport B Um Sch den zu vermeiden d rfen die L schkammern und Trennmesser nicht als Haltegriffe oder als Angriffspunkt f r Transportmittel verwendet werden Das Schaltger t am Grundrahmen bzw an der Traverse anheben und transportieren Bei allen Transportbewegungen das Mit telspannungs Schaltgerat gegen Kippen si chern Auf gleichm ige Gewichtsverteilung achten Ger te nicht auf die L schkammern legen und nicht auf bzw ineinanderstapeln Nach dem Abladen e Mittelspannungs Schaltger te und Zube h r auf Transportsch den pr fen e das Zubeh r laut Lieferschein auf Voll st ndigkeit kontrollieren Transportsch den dokumentieren und sofort dem Spediteur der Versicherung und der Firma DRIESCHER melden Assembly Unloading and Transporting Comply with safety instructions page 10 and
20. AR Ah Ut te al ao ne di ri Bu ws 57 5 tT beiTinksantrieb 1 for left side drive 8 wo s e i lb f NELA A E 40 x B Y zul ssige Anschlu breite 50mm 40 Bei Rechtsantrieb Hilfslager notwendig bei Ma Y gt 150 mm Bei Linksantrieb Hilfslager notwendig bei Ma X 2 150 mm Hilfslager Typ HLBF H 40 140 mm verstellbar in case of right side drive auxiliary bearing needed when dimension Y gt 150 mm in case of left side drive auxiliary bearing needed when dimension X gt 150 mm auxiliary bearing type HLBF H 40 140mm adjustable Ma e Dimensions Typ Type B gedr ngte Bauart Compact design D DIN Schalter DIN switch M P x Y B D M P x LDTM 24 630 SF E SEA E 804 628 74 240 190 190 750 774 112 275 190 190 LDTM 17 DRIESCHER e WEGBERG gepr fte Anschlu zone p 240 i Tested connection zone p 240 das angegebene Ma ist einzuhalten f r Sicherungseinsatz nach VDE 0670 Teil 4 Bauform I The specified dimension must be adhered to for fuse link per IEC 60282 1 type I 19 gepr fte Anschlu zone N p 240 i Tested connection zone p 240 wl 5 i n 19 Hilfslagerbock f r 19 Antriebsseite links Auxiliary bearing block for left side drive o a q 18 a 6 5 i I 19 q 6 q Hilfslagerbock f r Antriebsseite links
21. Montage und Betriebsanleitung Operation and Assembly Instructions Luftisolierte Mittelspannungs Air Insulated Medium Voltage Innenraum Schaltger te Indoor Switches Typ LDTM S EA S F Type LDTM S EA S F 12 kV 24 kV 630 A 12 kV 24 kV 630 A 01 2002 DRIESCHER e WEGBERG 2 LDTM DRIESCHER e WEGBERG ALLGEMEINES cc ccccsssctssesssenseseessseseeneas 3 GENERAL INFORMATION 3 BESTIMMUNGSGEMARE VERWENDUNG 3 USE AS INTENDED 3 NORMEN UND VORSCHRIFTEN 3 STANDARDS AND SPECIFICATIONS 3 BETRIEBSBEDINGUNGEN RE RD CINI 3 OPERATING CONDITIONS 3 HAFTUNGSBESCHRANKUNGEN te 4 RESTRICTIONS ON LIABILITY 4 GEWAHRLEISTUNG 5 WARRANTY 5 KUNDENDIENST 0cccccccceeeceeeceeeeeeees 6 CUSTOMER SERVICE 6 SICHERHEITSVORSCHRIFTEN 7 SAFETY REGULATIONS 7 ALLGEMEINES 7 GENERAL INFORMATION 7 HANDHABUNG 8 HANDLING Lelli 8 ARBEITEN AN MITTELSPANNUNGS WORKING ON MEDIUM VOLTAGE SCHALTGERATEN ERR PRN Ro RE weeded 9 SWITCHES uil ila a 9 FUNF SICHERHEITSREGELN EEE aa REN 10 FIVE SAFETY RULES 10 SICHERHEITSHINWEISE F R TRANSPORT SAFETY INSTRUCTIONS FOR TRANSPORT MONTAGE
22. VDE 0670 Teil 4 Ausl sekraft min 50 N Uber Ausl semagnet 24 220 V DC oder 80 230 V AC siehe Anhang A Betatigung Lasttrennschalter einschalten Die Antriebswelle nach oben bet tigen und den Schaltvorgang beachten Lasttrennschalter ausschalten Die Antriebswelle nach unten betatigen und den Schaltvorgang beachten Lasttrennschalter mit angebautem Erdungsschalter und mechanischer Verriegelung l t sich nur bei ausge schaltetem Erdungsschalter schalten bzw Erdungsschalter nur bei ausgeschaltetem Lasttrennschalter Schalten des Erdungsschalters Der dreipolige Erdungsschalter ist mit einer Schnelleinschaltung ausger stet und damit kurz schlu einschaltfest Erdungsschalter einschalten Die Antriebswelle nach oben bet tigen und den Schaltvorgang beobachten Erdungsschalter ausschalten Die Antriebswelle nach unten bet tigen und den Schaltvorgang beobachten Switching Operations Operating the Switch disconnector Type F The switch disconnector is turned ON and OFF with a switch lever The built in spring loaded swit ching device ensures that the switch can be turned ON and OFF safely regardless of the operating speed Type SEA The switch disconnector with independent trip type S EA features an energy storing device that is placed under tension when the switch disconnector is turned ON The trip occurs via HV H R C fuses with striker pin class Medium in accordanc
23. ahmen der Weiterentwicklung der in dieser Bedienungsanleitung behandelten Schaltgerate behalten wir uns vor Aus den Angaben Abbildungen und Beschreibungen dieser Bedienungsanleitung k nnen daher keine Anspr che hergeleitet werden Customer Service Our Customer Service is at your disposal for all technical information regarding DRIESCHER pro ducts and their systems engineering applications If difficulties with our products arise please con tact the responsible representative or the manu facturing factory If you have any questions or if you wish to order replacement parts please specify the following data shown on the nameplate type of switch job number serial number model year rated voltage and rated current value Specifying these items ensures that you will recei ve the correct information or required replacement parts Fritz Driescher KG Spezialfabrik fur Elektrizitatswerksbedarf GmbH amp Co Postfach 1193 D 41844 Wegberg Germany Industriestrasse 2 D 41844 Wegberg Germany Tel 49 2434 811 Fax 49 2434 81 446 www driescher wegberg de e mail info driescher wegberg de We reserve the right to make technical changes during the further development of the switches discussed in these In structions for Operation Consequently no claims can be based on the data illustrations and descriptions in these In structions for Operation LDTM DRIESCHER e WEGBERG Sicherheitsvorschrift
24. angle of the crank whose radius can be adju sted should be as obtuse as possible without however reaching the dead center position Setup 2 In the ON position linkage and switch crank should form an optuse angle the crank must be in an sharp angle position Here too the dead center position is not to be achieved in any switch positi on Note All switch disconnector and earthng swit ches can be equipped with manual or motorized drives whichever you request You may request the documents if you wish LDTM 31
25. bsanleitung den Sicherheitsvorschriften und den Texten die durch Sicherheitssymbole gekennzeichnet sind sind folgende allgemeine Vorschriften f r die Handhabung der Mittelspannungs Schaltger te bindend AnschluBbedingungen der rtlichen Elektrizi t tsversorgungsunternehmen EVU Europ ische Sicherheitsvorschriften EU Norm Sicherheit von Maschinen Ger ten und Anlagen In L ndern au erhalb der EU die entspre chenden Sicherheitsvorschriften Handling These Operation and Assembly Instructions should make it easier for the owner operator to perform the work safely and properly and to carry out the maintenance on the medium voltage swit ches Everyone assigned to transport installation commissioning operation and maintenance duties on the medium voltage switches must have read and understood the Operation and Assembly Instructions the safety regulations and the safety notes in the individual chapters and sections To avoid operator errors and to ensure troublefree operation of the medium voltage switches the Operation and Assembly Instructions must always be accessible to the owner operator Aside from these Operation and Assembly In structions the safety regulations and the texts identified by safety symbols the following general specifications are binding for handling the medium voltage switches connection conditions of your local power supply companies European safety regulation
26. ce jobs are carried out by qualified electrical technicians who have read and understood the Operating Instructions Use only the proper transport and lifting equip ment for the transport and lifting of the medium voltage switches or portions thereof Use only load suspension devices and slings that are in proper condition and place them in the relevant positions LDTM 11 DRIESCHER e WEGBERG Technische Daten Technical Data Bemessungsgr en Rated values Bemessungsspannung 12 kV 24 kV Rated voltage Bemessungsstrom 630 A 630 A Rated current Bemessungs Kurzzeitstrom 20 kA 16 kA Rated short time current Bemessungs Einschaltstrom 50 kA 40 kA Rated Short circuit ao Bemessungs Lastausschaltstrom 630 A 630 A Rated mainly active lodd breaking current Bemessungs Ringausschaltstrom 630 A 630 A Rated closed loop breaking current Bemessungs Kabel und 25 A 25 A Rated cable and line charging Freileitungsausschaltstrom breaking current Bemessungs Ausschaltstrom unter Rated breaking current under earth 300 A 300 A ae ErdschluBbedingungen leakage condition Bemessungs Stehblitzsto spannung 75 8510 iesms ky Pata lightning impulse te Bemessungs Transformatorausschalt Rated no load transformer breaking 6 3 A 6 3 A strom current Zul Umgebungstemperaturen 25 C 60 C Ambient Temperature Abmessungen LDTM 12 24 kV 1 Wird Antriebsseite Links gew nscht Ma X s
27. ch ON and OFF a number of times and check the switching se quence as well as the functions Diagram Schalter EIN Switch ON Schalterseite 0 5 1mm Spiel DB S gt S 689 mm LDTM 12 630 SF E und SEA E S 854 mm LDTM 24 630 SF E und SEA E Bild 1 Abschlie ende Montagearbeiten Alle Arbeiten am Schaltgerat beenden Alle nicht mehr erforderlichen Werkzeuge Anschlagmittel und Hilfsmittel entfernen Sequence of Mounting see Fig 1 Final Assembly Steps Finish all work on the switch Remove all tools lifting devices and aids that are no longer required LDTM 25 DRIESCHER e WEGBERG Betrieb Inbetriebnahme e Sicherheitsvorschriften Seite 10 und Unfall verhutungsvorschriften beachten e Montagearbeiten pr fen Kontrollieren ob alle Montagearbeiten ordnungsgem durchgef hrt sind e Mechanische Funktionen pr fen siehe Seite 22 B Die Hochspannung darf nicht eingeschaltet sein e Hilfs und Steuerspannung zuschalten e Alle getroffenen Schutzma nahmen wie Kurz schlu amp und Erdungsverbindungen so aufhe ben da keine Gef hrdung f r Personen und Sachen auftritt Bedienpersonal unterrichten Dem Bedienpersonal Elektrofachkraft vor Inbetriebnahme des Schaltger tes die Montage und Betriebsanleitung aush ndigen Das Bedienpersonal mu bei
28. e interlocking linkage 3 and the spacer 4 are included in the shipment not installed During assembly the function of the mechani cal interlock must be restored Mounting se quence see page 24 24 LDTM DRIESCHER e WEGBERG Montagefolge siehe Bild 1 Schalter in EIN Stellung Erder in AUS Stellung bringen Das beigepackte Verriegelungsgestange 3 und den Distanzhalter 4 auf die Wellen in der unten dargestellten Anordnung anbringen Die beigepackte Zylinderschraube 1 M12x25 DIN 912 A2 70 in die Verriegelungsscheibe 2 einschrauben und mit einem Anzugs drehmoment von My 86 Nm anziehen Das Spiel zwischen Verriegelungsscheiben A und Verriegelungsbolzen B soll zwischen 0 5 1 0 mm betragen Nach der Montage Distanzhalter 4 entfernen Schalter und Erder mehrmals Ein Ausschal ten und Schaltablauf sowie Funktionen pr fen Darstellung Erder AUS Earthing switch OFF 2 1 Move switch to ON position Earthing switch to OFF position Mount the interlocking mechanism 3 and spacer 4 included with the shipment on the shafts in the order illustrated below Screw the cylindrical bolt 1 M12x25 DIN 912 A2 70 included with the shipment into the in terlocking disk 2 and tighten to My 86 Nm with a torque wrench The clearance between interlocking disk A and interlocking pin B should be between 0 5 to 1 0 mm Remove spacer 4 after mounting Turn switch and earthing swit
29. e with IEC 60232 re lease force min 50 N via trip coil 24 220 VDC or 80 230 VAC see Annex A Actuation Turning ON the switch disconnector Move the actuating shaft up and observe the switching operation Turning OFF the switch disconnector Move the actuating shaft down and observe the switching operation Es switch disconnector with attached earthing switch and mechanical interlock can only be actuated when the earthing switch is OFF and the earthing switch can only be actuated when the switch disconnector is turned OFF Actuating the Earthing Switch The 3 pole earthing switch is equipped with a quick acting device and is therefore short circuit make proof Turning the earthing switch ON Move the actuator shaft up and observe the switching operation Turning the earthing switch OFF Move the actuator shaft down and observe the switching operation LDTM 27 DRIESCHER e WEGBERG Instandhaltung Wartung DRIESCHER Mittelspannungs Schaltger te sind wartungsarm Der Wartungsturnus liegt im Ermessen des Betrei bers Der Turnus ist abh ngig von den unter schiedlichen Betriebs und Umgebungsbedingun gen am Einsatzort EA Sicherheitsregeln beachten Schaltger t beidseitig freischalten und Spannungs freiheit pr fen Alle Schalter Isolierbauteile sollten von Fremdschichtablagerungen gereinigt werden Dazu flusenfreie T cher verwenden Keine Sprays Pasten oder sonstige L su
30. en Allgemeines Die in der Bedienungsanleitung enthaltenen Hin weise Zu Transport Montage Inbetriebnahme Bedienung Wartungsarbeiten der Mittelspannungs Schaltger te m ssen unbe dingt eingehalten werden Wichtige Hinweise wie sicherheitstechnische Hinweise sind durch folgende Symbole gekenn zeichnet Befolgen Sie diese Hinweise um Unf lle und Besch digungen der Mittelspannungs Schaltger te zu vermeiden A Warnung vor einer Gefahrenstelle EA Warnung vor elektrischer Spannung UH Weist auf Richtlinien und Vorschriften hin die eine Besch digung der Schaltger te oder Gef hrdung von Personen verhin dern Diese Symbole finden Sie bei allen Hinweisen in dieser Montage und Betriebsanleitung bei denen Gefahr f r Leib und Leben besteht Beachten Sie diese Hinweise und geben Sie die se an andere Elektrofachkr fte weiter Neben diesen Hinweisen sind Sicherheitsvorschriften Unfallverh tungsvorschriften Richtlinien und anerkannte Regeln der Tech nik sowie s mtliche Instruktionen dieser Montage und Be triebsanleitung zu beachten Safety Regulations General Information It is imperative that the notes in these Operating Instructions regarding transport assembly putting into service operation maintenance jobs of the medium voltage switches must be adhered to Important instructions such as safety notes are identified by means of the following
31. en top the HV H R C fuse is blows HV H R C fuse Insert HV H R C actuating force doesn t corre spond to class Medium per IEC 60282 1 fuse with at least 50 N actuating force and 20 mm minimum stroke of the striker pin LDTM 29 DRIESCHER e WEGBERG Annex A trip coil Anhang A Magnetausl ser The trip coil auxiliary coil 24 60 V DC and 110 Der Magnetausl ser Hilfsausl ser 24 60 V DC 230 V AC is not designed for 100 ON time so und 110 230 V AC ist nicht fur 100 Einschalt always shut OFF the circuit via the auxiliary switch dauer ausgelegt deshalb den Stromkreis immer Uber den Hilfsschalter abschalten Bei DC 24 60 V wird 1 Hilfsschalter zur Un terbrechung verwendet der beim Ausschalten des LDTM ffnet Bei DC 110 220 V werden zus tzlich ein Hilfsschalter und ein Entst rkondensator ver wendet Bei AC 110 230 V wird eine Diode zur Ein weg Gleichrichtung verwendet DC 24 60 V DC 110 220 V Y1 Y1 24V DC MS Tas 24V DC Lia 5 ED i 100 ED In the case of DC 24 60 V one auxiliary switch is used for the interruption it opens when the LDTM is switched OFF In the case of DC 110 220 V a second auxi liary switch and a suppression capacitor is also employed In the case of the AC 110 230 V a diode is employed for the one way rectifier X1
32. enutzen und an den daf r vorgesehenen Stellen anschlagen Five Safety Rules 1 Isolate Isolate both sides of the medium voltage swit ches where the work is being performed on 2 Secure against switches being reclosed Set up an information sign on the disabled switches indicating what was isolated reason for the isolating name of the person who isolated Secure the switches in a suitable manner e g padlock the drive to prevent them from being turned back on 3 Check absence of voltage Check to make certain that the voltage tester is functioning properly and that there is no voltage present 4 Earth and short circuit Using the earthing switch or a earthing and short circuiting device earth and short circuit the pertinent cable ends via short circuit bolts 5 Set up barriers around neighboring parts that are live and cover them up Risks if safety instructions are not complied with Failure to observe the safety notes leads to en dangerment of persons and damage to the swit ches This will culminate in the loss of any and all claims for compensation for damage and may cause the following injury of persons due to dangerous electrical voltage failure of important functions of the switches failure of specified methods of maintenance and service Safety instructions for transport as sembly operation and maintenance The owner must make certain that all transport operation and maintenan
33. fslagerbock f r u Antriebsseite links Auxiliary bearing block for drive side left I I eli le tea a ii it tt sa z Ed bei Linksantrieb 2 for left side drive x B X zul ssige AnschluBbreite 50 mm p 145 Permissible connection width 50mm p 145 Bei Rechtsantrieb Hilfslager notwendig bei Ma Y gt 150 mm Bei Linksantrieb Hilfslager notwendig bei Ma X 150 mm Hilfslager Typ HLBF H 40 140 mm verstellbar in case of right side drive auxiliary bearing needed when dimension Y gt 150 mm in case of left side drive auxiliary bearing needed when dimension X 150 mm auxiliary bearing type HLBF H 40 140mm adjustable Ma e Dimensions Typ Type B gedr ngte Bauart Compact design D M P x Y B DIN Schalter DIN switch D M P x Y LDTM 12 630 F E EA E 414 438 74 145 150 150 600 624 102 210 150 150 LDTM 13 DRIESCHER e WEGBERG LDTM 12 630 SF SEA gepr fte AnschluBzone p 145 Tested connection zone p 145 115 15 451 248 414 872 das angegebene Ma ist einzuhalten f r Sicherungseinsatz nach VDE 0670 Teil 4 Bauform The specified dimension must be adhered to for fuse link per IEC 60282 1 type 115 36 gepr fte Anschlu zone p 145 Tested connection zone p 145 Ausl sevorrichtung nur bei Typ SEA Tripping device onl
34. haltet hat Durch geeignete Verriegelung z B Vorhan geschlo am Antrieb das Wiedereinschalten verhindern 3 Spannungsfreiheit pr fen Spannungspr fer auf einwandfreie Funktion pr fen und die Spannungsfreiheit feststellen 4 Erden und Kurzschlie en Mit Hilfe des Erdungsschalters bzw mit Er dungs und KurzschlieRvorrichtung Uber Erd schluRbolzen die jeweiligen Leitungsenden erden und kurzschlieBen 5 Benachbarte unter Spannung stehende Teile abschranken und abdecken Gefahren bei Nichtbeachtung der Sicherheits hinweise Die Nichtbeachtung der Sicherheitshinweise f hrt zur Gef hrdung von Personen und zur Besch di gung der Schaltger te Dies f hrt zum Verlust jeglicher Schadensersatz anspr che und kann folgendes nach sich ziehen Verletzung von Personen durch gef hrliche elektrische Spannungen Versagen wichtiger Funktionen der Schaltge r te Versagen vorgeschriebener Methoden zur Wartung und Instandhaltung Sicherheitshinweise f r Transport Montage Betrieb und Wartung Der Betreiber sorgt daf r da alle Transport Montage Bedienungs und Wartungsarbeiten von Elektrofachkr ften ausgef hrt werden welche die Bedienungsanleitung gelesen und verstanden haben F r den Transport und das Heben des Mit telspannungs Schaltger tes bzw von Ger tetei len nur die daf r vorgesehenen Transport und Hebemittel verwenden Lastaufnahmemittel und Anschlagmittel nur in einwandfreiem Zustand b
35. haltge r te nicht zu beeinflussen ist bei der Montage darauf zu achten da der Schalterranmen beim Anziehen der Befestigungsschrauben nicht verspannt wird Unebenheiten sind unbe dingt durch Unterlagen im Bereich der Befesti gungsbohrungen auszugleichen Die Schaltger te sind mit Befestigungsschrau ben M12 zu befestigen Schalter Typ Anzahl der Schrauben siehe Seite 12 17 M12 F EA 4 F E EA E 6 SF SEA 6 SF E SEA E 8 Beim Einbau von Antrieben mu besonders beachtet werden da die Schalterantriebs welle erst bei einem Drehwinkel von min 95 bei Schaltger ten vom Typ F und 110 bei Schaltger ten vom Typ EA von der Aus gangslage den Schaltvorgang vollendet Es ist ebenso wichtig da beim Anschlie en der Leitungen die Kontaktanschlu st cke nicht verzogen oder verspannt werden mit zweitem Schl ssel gegenhalten Bei Antriebswellen mit Y gt 150 mm bei Rechtsantrieb bzw X gt 150 mm bei Links antrieb ist ein Hilfslagerbock Typ HLBF zu verwenden Art Nr 0067319 Erforderliche Erdverbindung zum Schalterrah men herstellen ched horizontally The switch is only suitable for vertical rack and wall mounting Other installation positions must be reported to Driescher since additional attachments are necessary So as not to detrimentally influence the me chanical function of the switches make certain during mounting that the switch frame is not
36. igung des Herstellers erforderlich F r Sch den die aus der ungenehmigten Ver wendung von Fremdprodukten resultieren sowie sich aus eigenm chtigen Ver nderungen oder Umbauten an unseren Produkten oder Zubeh r ergeben ist jede Haftung des Herstellers ausge schlossen Gewahrleistungsdauer Die Gew hrleistung dauert 12 Monate ab Auslie ferung Warranty These Operation and Assembly Instructions con tain all required notes and must be read through carefully before placing the medium voltage swit ches into service We accept no liability for damage and operational disruptions resulting from failure to comply with the Operation and Assembly Instructions Claims under the warranty must be reported in writing complete with the contract number imme diately after the defect is discovered The warranty is null and void in the event of improper handling use not as intended impermissible equipment faulty erection incorrect or nonprofessional connection of medium voltage cables or the auxiliary control lines Driescher HV H R C fuses accessories and re placement parts are specially constructed and tested in time consuming test series We ex pressly point out that replacement parts not supp lied by the manufacturer and the accessory parts not recommended by the manufacturer are also not approved by the manufacturer Installing and using third party products may negatively affect structurally specified
37. itions In accordance with IEC 60694 the manufacturer and the owner can agree to operating conditions that deviate from the standard conditions The manufacturer must be asked in advance about any special service condition Instructions regarding any climatic special operating conditions When switches are operated in areas with a high relative humidity and or if temperatures fluctuate briefly there is a danger of frequent condensation To avoid impermissible condensation phenomena and corrosion this may cause countermeasures must be taken e g electric heater after consul ting with the manufacturer Restrictions on Liability All of the technical information data and notes about the installation operation and maintenance of the medium voltage switches contained in the se Operation and Assembly Instructions are cur rent as of the day of printing and are stated to the best of our knowledge on the basis of our experi ence and know how We accept liability for any errors or omissions to the exclusion of further claims within the scope of the agreed warranty Claims for compensation for damage are excluded regardless of the legal basis for those claims unless they are the result of intent or gross negligence Translations are made to the best of knowledge Liability of any kind shall therefore not be accep ted for faults made in the translation even if the operating instructions are translated by us or by a third party
38. kidney shaped recess on the side frame The minimum angle of rotation for the switching movement of the actuating shaft is 95 in case of switches type F and 110 in case of switches type EA If the switch is actuated via linkage mechanisms or the like note the special information and setting instructions in Annex B LDTM 23 DRIESCHER e WEGBERG Mechanische Verriegelung Schalter Erder Option Mechanische Verriegelung prufen 1 Schalter in EIN Stellung Erder in AUS Stel lung Erder ist verriegelt 2 Schalter in AUS Stellung Erder in EIN Stel lung Schalter ist verriegelt 3 Aus Transportgr nden werden Schalter und Erder in EIN Stellung gebracht hierbei ist die Funktion der Verriegelung aufgehoben Bei Geraten Typ LDTM SEA E ist das Verrie gelungsgestange 3 und der Distanzhalter 4 lose beigepackt 4 Bei der Montage mu die Funktion der me chanischen Verriegelung wiederhergestellt werden Montagefolge siehe Seite 24 Mechanical Interlocking switch disconnector earthing switch Optional Check mechanical interlocking 1 Switch in ON position Earthing switch in OFF position Earthing switch is interlocked Switch in OFF position Earthing switch in ON position Switch is interlocked For the purposes of transport switch and earthing switch are moved to the ON position the function of the interlock is cancelled In the case of switches type LDTM SEA E th
39. ngsmittel benutzen hierdurch k nnten Kunststoff Oberfl chen besch digt werden Eventuell nach der Reinigung erkennbare Isolationssch den m ssen behoben werden Hiermit ist der Hersteller zu beauftragen Die Kontaktgleitfl chen sind nur mit Paraffin in fester Form zu behandeln Es d rfen keinesfalls herk mmliche Schmiermittel Fette le verwendet werden Bei einer Schwerg ngigkeit im mechanischen Bewegungsablauf sollten die Lagerstellen der Antriebsmechanik mit einem kriechf higen Spr h l behandelt werden Spr h le haben den Vorteil da auch wirklich die Stelle vom Schmierstoff getroffen wird die eine Schwerg ngigkeit verursacht Unabh ngig vom verwendeten Schaltertyp sollte der Betreiber darauf achten da die Stationsr u me sauber und trocken sind Nach der Wartung sind vor der Inbetriebnahme einige Probeschaltungen durchzuf hren Maintenance Service DRIESCHER medium voltage switches require little maintenance The regular schedule for maintenance is at the discretion of the owner The schedule depends on the different operating and environmental conditi ons at the site 4 Observe safety rules Disable switch on both sides and test for absence of voltage All switch insulation components should be cleaned to remove films of foreign materials Use lint free cloth for this purpose no sprays pastes or other solvents These could damage plastic surfa ces Any insulation damage recognizable
40. nungs Schalt ger te Normen Betriebsbedingungen Normale Betriebsbedingungen Die Schaltger te sind f r normale Betriebsbedin gungen von Innenraum Schaltger ten und Schaltanlagen nach VDE 0670 Teil 1000 ausge legt General Information Use as Intended The DRIESCHER LDTM switches are type tested AC switch disconnectors or earthing switches for indoor use with voltages from 12 to 24 kV The general purpose switch disconnector is sui table to interrupt currents up to 630 A and to form an isolating distance in accordance with EN50110 1 Standards and Specifications Specifications of the German Trade Association BGV A1 VBG 1 BGV A2 VBG 4 General specifications Electrical systems and equipment Standards DIN VDE 0101 Power installations excee ding AC 1kV EN50110 1 Operation of electrical in stallations IEC 60129 Alternating current discon nectors and earthing swit ches IEC 60265 1 High voltage switches IEC 60420 High voltage alternating cur rent switch fuse combina tions IEC 60694 Common specifications for high voltage switches and controlgear standards Service Instructions Standard service conditions The switches are designed for normal service conditions of indoor switches and switching sy stems as per IEC 60694 Ambient temperature Umgebungstemperatur Maximum value 60C H chstwert 60 C Lowest value 25 C Tiefstwert 25 C 4 LDTM DRIESCHER e WEGBERG
41. o ist dies in der Bestellung beson ders anzugeben Ohne besondere Be stellangaben Antriebsseite Rechts mit Ma y 150 mm bei 12 kV 190 mm bei 24 kV Dimensions of LDTM 12 24 kV 1 If drive side left is desired dimension X indicate this specifically in the order If not in dicated specifically in the order the drive side will be the right side with dimension Y 150 mm 12kV 190 mm at 24kV 12 LDTM DRIESCHER e WEGBERG gepr fte Anschlu zone p 145 Tested connection zone p 145 T w il ise oO I i o 8 f gepr fte Anschlu zone p 145 Tested connection zone p 145 95 LDTM 12 630 F EA E b14 451 248 55 414 7 7 322 515 Mechanische Verriegelung Mechanical interlock Antriebswelle Schaltwinkel 95 Typ F Hilfslagerbock f r Antriebsseite links 110 Typ EA Bet tigungsseite rechts Actuator shaft actuating angle 95 Type F 110 Type EA Actuating side right Antriebswelle Schaltwinkel 95 Betatigungsseite rechts Actuator shaft actuating angle 95 Actuating side right Auxiliary bearing block 8 for drive side left fe ui 8 N L 4 5 i o j a N AA ta o i a p t i o q 4 T Hil
42. s EU standard Safety of Machines Devices and Systems the pertinent safety regulations in countries outside of the EU LDTM DRIESCHER e WEGBERG Arbeiten an Schaltgeraten Mittelspannungs Betrieb Arbeiten und Bedienung an Mittelspan nungs Schaltger ten d rfen nur Elektrofachkr fte gem Definition in VDE 0105 ausf hren unter Beachtung der jeweils g ltigen VDE Vorschriften 5 Sicherheitsregeln nach VDE Sicherheitsvorschriften Unfallverh tungsvorschriften Bedien und Zubeh rteile m ssen jederzeit f r die Elektrofachkraft vorhanden zug nglich und in ordnungsgem em Zustand sein Sie d rfen kei ne Besch digungen aufweisen Ersetzen Sie besch digte Bedien und Zubeh r tele durch gepr fte oder zugelassene DRIESCHER Teile Zust ndigkeiten und Bedienungsablaufe f r Be dienung und Wartung m ssen geregelt sein und eingehalten werden Elektrofachkraft Als Elektrofachkraft laut VDE 0105 gilt wer auf Grund seiner fachlichen Ausbildung Kenntnisse und Erfahrungen sowie Kenntnisse der einschla gigen Bestimmungen die ihm bertragenen Ar beiten beurteilen und m gliche Gefahren erken nen kann Ek Die Elektrofachkraft mu von dem f r die Sicherheit der Schaltger te Verantwortli chen berechtigt sein die jeweils erforder lichen Arbeiten und T tigkeiten auszuf h ren Work on Medium Voltage Switches Only qualified electrical technicians as per defini tion
43. switch BED SM P XV LDTM 24 630 F E EA E 604 628 74 240 190 190 750 774 112 275 190 16 LDTM 190 DRIESCHER e WEGBERG gepr fte Anschlu zone p 240 Tested connection zone p 240 das angegebene Ma ist einzuhalten f r Sicherungseinsatz 215 nach VDE 0670 Teil 4 Bauform The specified dimension must be adhered to for fuse link per IEC 60282 1 type gepr fte Anschlu zone p 240 Tested connection zone p 240 Hilfslagerbock f r Antriebsseite links Auxiliary bearing block for left side drive p 2 Permissible connection width 50mm p 240 LDTM 24 630 SF SEA 328 15 a a Ausl sevorrichtung nur bei Typ SEA 1145 Ea Tr Tripping device only I i di for type SEA o Hilfsblech optional i Auxiliary plate optional al TH THH i g 914 7 a 397 705 El D M P P M en ini u Antriebswelle Schaltwinkel 95 Typ F 40 110 Typ EA Bet tigungsseite rechts I m Actuator shaft actuating angle 95 Type F gl 110 Type EA E tf 4 Actuating side right te V7 Tr Bir TT ja Hilfslagerbock f r Antriebsseite rechts 8 fA il 4 Auxiliary bearing block m i for right side drive o Hr ar t wo E AR
44. symbols Fol low these notes to avoid accidents and damage involving the medium voltage switches A Warning of a danger area EA Warning of electrical voltage Refers to guidelines and specifications which prevent damage to the switches or endangerment of persons You will find these symbols with all notes in these Operating and Assembly Instructions Comply with these notes and pass them on to other qualified electrical technicians Aside from these notes comply with safety specifications accident prevention regulations guidelines and recognized rules of technolo gy as well as all instructions and notes in these Operation and Assembly Instructions LDTM DRIESCHER e WEGBERG Handhabung Diese Montage und Betriebsanleitung soll dem Betreiber Bediener das sichere und sachgerechte Arbeiten sowie die Wartung der Mittelspannungs Schaltgerate erleichtern Jede Person die mit Transport Installation Inbe triebnahme Bedienung und Wartung der Mit telspannungs Schaltger te beauftragt ist mu die Montage und Betriebsanleitung die Sicherheitsvorschriften und die Sicher heitshinweise der einzelnen Kapitel und Ab schnitte gelesen und verstanden haben Um Bedienungsfehler zu vermeiden und einen st rungsfreien Betrieb der Mittelspannungs Schaltger te zu gew hrleisten mu die Montage und Betriebsanleitung dem Betreiber Bediener stets zug nglich sein Neben dieser Montage und Betrie
45. tional 12 kV Schalter amp Erder Ma x 150mm Ident Nr 0066233 Ident Nr 0010001 je 1 Antriebsstutzen je 1 Spannstift 8x 28 je 1 Spannstift 5x 28 Ident Nr 0010002 24 kV Schalter amp Erder Ma x 190mm Ident Nr 0066234 Ident Nr 0010001 je 1 Antriebsstutzen je 1 Spannstift 8x 28 je 1 Spannstift 5x 28 Ident Nr 0010002 Von Links auf Rechts Die Spannstifte Y 8 5 1 beidseitig austreiben Auf der linken Seite den Antriebsstutzen 4 und die Spannstifte entfernen Die innenliegende Welle 20 3 nach rechts durchschieben und mit der Antriebsscheibe rechts 2 optional Ma y be achten und Spannstifte 8 5 verstiften E Bei Rechtsantrieb Ma y gt 150mm immer Hilfslager verwenden Optional 12 kV Schalter amp Erder Ma y 150mm Ident Nr 0066239 Ma y 190mm Ident Nr 0066240 je 1 Antriebsscheibe 24 kV Schalter amp Erder je 1 Antriebsscheibe Later change of operating side From rigth side to left side Drive off the clamping pins diameter 8 5 1 at right side of the drive disc 2 displace the inside situa ted shaft with diameter 20 3 to the left and drive in again the clamping pins Pin together the drive stud 4 at left side with clamping pins diameter 8 5 consider optional size x HS In case of left hand side operation always use auxiliary bearings Option 12kV switch and earthing switch size
46. x 150mm each 1 drive stud Ident Nr 0066233 each 1 clamping pin 8x28 Ident Nr 0010001 each 1 clamping pin 5x28 Ident Nr 0010002 24 kV switch and earthing switch size x 190mm each 1 drive stud Ident Nr 0066234 each 1 clamping pin 8x28 Ident Nr 0010001 each 1 clamping pin 5x28 Ident Nr 0010002 From left side to right side Drive off the clamping pins with diameter 8 5 1 on both sides Remove the drive stud 4 and the clamping pins at left side Push the inside situated shaft diameter 20 3 to the right and pin same together with the drive wheel right 2 Consider size Y as option and pins diameter 8 5 HS In case of right hand side with size y gt 150mm always use auxiliary bearings Option 12 kV switch and earthing switch size y 150mm Ident Nr 0066239 24 kV switch and earthing switch size y 190mm Ident Nr 0066240 each 1 drive disc each 1 drive disc 21 DRIESCHER e WEGBERG Vorbereiten von Lasttrennschalter Typ S EA Schaltgerate vom Typ S EA mit Ausl sekraftspei cher werden mit ausgeh ngter Ausschaltfeder angeliefert ungen der Ausschaltfeder Entfernen Sie die Transporthilfen 2 und 3 Bringen Sie von Hand die Trennmesser 7 durch eine Zugbewegung der Schaltgest nge 4 in AUS Stellung H ngen Sie das Hilfswerkzeug 9 mit dem Haken in das Ende der Ausschaltfeder 1 Hebeln Sie mit einem gro en Schraubendre her durch die se
47. y for type SEA i q a Hilfsblech optional 1 lt Auxiliary plate optional i poh He amp E a 614 322 la 515 D P P M 40 Hilfslagerbock f r 9 Antriebsseite links EA Antriebswelle Schaltwinkel 95 Typ paa 110 Typ Bet tigungsseite rechts Auxiliary bearing block LS for drive side left Se Actuator shaft actuating angle 95 Type F J aa 110 Type EA o i h r y si Actuating side right o LL N iy 1 Ir ii E tina et 1H ia VEE bei Linksantrieb 1 for left side drive a o x i N Mn not 40 x B X zul ssige Anschlu breite 50mm p 145 Permissible connection width 50mm p 145 Bei Rechtsantrieb Hilfslager notwendig bei Ma Y gt 150 mm Bei Linksantrieb Hilfslager notwendig bei Ma X gt 150 mm Hilfslager Typ HLBF H 40 140 mm verstellbar in case of right side drive auxiliary bearing needed when dimension Y gt 150 mm in case of left side drive auxiliary bearing needed when dimension X gt 150 mm auxiliary bearing type HLBF H 40 140mm adjustable Ma e Dimensions Typ Type gedr ngte Bauart Compact design B D M P x Y B DIN Schalter DIN switch D M P x LDTM 12 630 SF E SEA E 414 438 74 145 150 150 600