1. MILLIPORE MILLI Q 85 PLUS User manual Manuel d utilisation Betriebsanleitung Manual de operaci n y mantenimiento Manuale operativo MILLIPORE Copyright Copyright O 1990 all rights reserved Millipore Corporation PF04517 Rev A 10 93 Trademarks Millipore is a registered trademark of Millipore Corporation MILLI RO MILLI RX DURAPORE are trademarks of Millipore Corporation ANATEL A 100 P is a trademark of ANATEL INSTRUMENT Corporation ENGLISH e Table of contents Table of contents Chapter 1 Introduction General description Description of function Schematic Specifications Chapter 2 Installation Unpacking Positioning of MILLI Q 185 PLUS Installation Inlet water connection Installation of purification pack Q PAK Chapter 3 Operation Standard modes of operation Additional displays Use of keyboard Electrical connections Startup Installation of final filter MILLIPAK 40 Withrawing water Chapter 4 Maintenance Maintenance schedule Replacement of Q PAK purification element Replacement of final filter MILLIPAK 40 Replacement of the U V lamp O o 000 0 NN N Os Os O Un I Co Y CO CO CO N Chapter 5 Troubleshooting Troubleshooting table Chapter 6 Appendix Appendix 1 Main fuse replacement Appendix 2 Main P C board fuse replacement Appendix 3 Replacement of fuse on U V Lamp P C board Chapter 7 Ordering information At back of
2. Purger le filtre Voir chapitre UTILISATION section mise en service MAINTENANCE 13 14 MAINTENANCE 6 ANNEXES e Annexe 1 Remplacement du fusible secteur e Annexe 3 Remplacement du fusible du circuit Figure 10 imprim de la lampe U V Figure 11 1 Mettre hors tension le MILLI Q 185 PLUS M me proc dure que l annexe 2 changer le fusible D du circuit imprim 2 D brancher et d connecter le cordon secteur de la lampe U V B 3 D gager le porte fusibles A 4 Retirer le fusible d fectueux B et le remplacer par le fusible neuf C NOTA Pr voir un fusible de remplacement l endroit pr vu cet effet 5 Replacer le porte fusibles dans son logement e Annexe 2 Remplacement du fusible circuit imprim principal Figure 11 1 Mettre hors tension le MILLI Q 185 PLUS D brancher le cordon secteur 2 D visser l crou molet voir figure 1 L pour enlever le capot arri re 3 Changer le fusible C du circuit imprim principal A ANNEXES 15 16 ANNEXES Fano D ACHAT Description R f rence SYSTEME MILLI Q 185 PLUS 220 V 50Hz ZFMQ 050 UV QPAK non inclu CONSOMMABLES Kit QPAK 1 MILLI Q aliment par eau osmos e CPMQ KOS RI comprend 1x QPAK 1 et un filtre MILLIPAK QPAK 1 seul CPMQ 004 R1 Kit QPAK 2 MILLI Q aliment par eau d ionis e CMPQ K05 D2 comprend 1 QPAK 2 et un filtre MILLIPAK QPAK 2 seul CMPQ 004 D2 Filtre MILLIPAK 0 22 um 2 pq MPGL 045 K2
3. Reverse Osmosis Distilled CPMQ K05 R1 includes 1x QPAK 1 and 1 x MILLIPAK filter QPAK 1 CPMQ 004 R1 QPAK 2 kit Feed water Deionised CMPQ K05 D2 includes 1x QPAK 2 and 1 x MILLIPAK filter QPAK 2 CMPQ 004 D2 MILLIPAK filter 0 22 um 2 pk MPGL 045 K2 U V lamp exchange kit CFMQ 185 01 ACCESSORIES Inlet pressure regulator ZFMQ 000 PR System wall mounting bracket ZFMQ 00W MB ORDERING INFORMATION 17 18 ORDERING INFORMATION FRANCAIS e Table des mati res Table des mati res Chapitre 1 Introduction G n ralit s Principe de fonctionnement Sch ma de principe Caract ristiques Chapitre 2 Installation D ballage Mise en place du MILLI Q 185 PLUS Installation Mise en place du pack de purification Q PAK Chapitre 3 Utilisation Modes de fonctionnement Messages compl mentaires Utilisation du clavier Connexion lectrique 4 l arri re Mise en service Mise en place du filtre final MILLIPAK 40 Soutirage de l eau Chapitre 4 Entretien Tableau des p riodicit s Remplacement du pack de purification Remplacement du filtre final MILLIPAK 40 Remplacement de la lampe U V ONNNOOO 01 I WWW N me O O O 0 Chapitre 5 Maintenance Tableau de maintenance Chapitre 6 Annexes Annexe 1 Remplacement du fusible secteur Annexe 2 Remplacement du fusible circuit imprim principal Annexe 3 Remplacement du fusible circuit imprim de la lampe U V Chapitre 7 Guide
4. 2 Dopo 6 secondi lampeggia l indicatore della luce U V G figura 1 Aspettare altri 30 secondi fino a che l indicatore mostra una luce fissa e la resistivit dell acqua ha raggiunto i 18 2 MQ x cm prima di prelevare l acqua Questa attesa permette alla lampada di raggiungere la temperature ottimale 8 FUNZIONAMENTO 3 Prelevare l acqua ruotando la valvola a 3 vie D figura 1 sulla posizione PRODUCTION 4 Per chiudere il prelievo ruotare la valvola a 3 vie sulla posizione RECIRCULATION Premere il pulsante OPERATE STANDBY per porre il sistema in modo STANDBY NOTA Quando non avete necessit di prelevare acqua lasciate il MILLI Q 185 PLUS in modo STANDBY Per poter mantenere inalterata la qualit dell acqua durante i periodi di non utilizzo il sistema ricircola automaticamente l acqua per 15 minuti ogni ora durante il modo STANDBY Il visualizzatore mostra RECIRCULATION Durante il modo STANDBY accertarsi che la valvola a 3 vie sia commutata su RECIRCULATION per evitare una fuoriuscita di acqua dal punto d uso durante i 15 minuti di ricircolo 4 MANUTENZIONE e Piano di manutenzione FREQUENZA AZIONE Quando l indicatore luminoso EXCHANGE PACK lampeggia o la resistivit non raggiunge i 18 2 MQ x cm dopo alcuni minuti di ricircolo Una volta all anno o quando l indicatore della lampada U V non si accende Quando la portata attraverso il filtro finale diventa troppo bassa Sostituire il b
5. B Punto d uso protetto C Punto d uso filtro finale con membrana da 0 22 um Unit MILLIPAK 40 D Valvola a 3 vie E Pannello di controllo F Leva di bloccaggio del Q PAK G Spie luminose H Visualizzatore a cristalli liquidi I Tastiera J Connessione d ingresso dell acqua di alimentazione K Tappo asportabile bloccaggio del manicotto per la staffa di montaggio a muro L Volantino di bloccaggio del pannello posteriore Presa femmina per il jack di comando a distanza N Alimentazione elettrica O Porta fusibile principale P Interruttore dell alimentazione Q Piastra dissipatrice di calore e Principio di funzionamento L acqua di alimentazione Osmotizzata o Distillata viene spinta dalla pompa del sistema attraverso una camera dove viene esposta alla luce ultravioletta U V a bassa lunghezza d onda 185 254 nm L esposizione agli U V permette l ossidazione dei composti organici non eliminati dal processo di pretrattamento Osmosi Inversa o Distillazione ed inoltre ha un effetto battericida L acqua cos trattata passa poi attraverso il blocco di purificazione Q PAK per la rimozione delle specie ioniche Una valvola a tre vie permette il ricircolo dall acqua fino al raggiungimento della qualit desiderata Raggiunta la qualit desiderata commutando la valvola a tre vie si effettua il prelievo attraverso il filtro finale MILLIPAK 40 e Schema Lo schema di funzionamento del Milli Q 185 Plus most
6. Cuando hayan salido entre 5 y 7 litros de agua sit e la v lvula de tres v as A en RECIRCULATION y presione dos veces la tecla OPERATE STANDBY para dejar el equipo en espera Si no necesita agua purificada inmediatamente deje el equipo as hasta la ma ana siguiente para permitir que el bloque QPAK se rehidrate totalmente 9 Por la ma ana presione la tecla OPERATE STANDBY Aparecer TEST MQ cm durante cuatro segundos y dos segundos despu s el piloto UV comenzar a parpadear durante 30 segundos indicando el calentamiento de la l mpara U V tras lo cual quedar encendido de forma continua Entonces abra la v lvula de tres v as y extraiga dos o tres litros de agua Presione de nuevo la tecla OPERATE STANDBY para dejar el equipo en espera e Instalaci n y purga del filtro final Millipak 40 figura 8 Si ya ha realizado los pasos anteriores purga rehidrataci n nocturna y nueva purga del bloque QPAK puede usted instalar el filtro final Millipak Proceder en otro orden podr a causar la obturaci n inmediata del filtro Millipak 1 Cubra la rosca macho A del filtro Millipak con dos o tres vueltas de cinta de Teflon para asegurar su estanqueidad 2 Enrosque el Millipak en el adaptador hembra C del punto de uso del equipo Aseg rese de que el orificio de venteo D del Millipak queda accesible 3 Presione de nuevo OPERATE STANDBY para situar el equipo en operaci n Sit e la v lvula de tres v as en
7. entfernen 4 Schrauben Sie den Millipak aus seiner AnschluBhalterung heraus 5 Bauen Sie einen neuen Millipak wie im Kapitel INSTALLATION beschrieben ein e Auswechseln der UV Lampe Abbildung 9 Der r ckw rtige Teil der Einheit mu entfernt werden Wenn das Milli Q Plus 185 System an der Wand installiert ist nehmen Sie es von der Wandhalterung 1 Schalten Sie das System aus und ziehen Sie den Netzstecker Abbildung 1 N P WARTUNG 9 2 L sen Sie die R ndelmutter Abbildung 1 L und den Stift f r die Wandhalterung Abbildung 1 K falls an der Wand montiert 3 Entfernen Sie die r ckw rtige Abdeckung indem Sie sie r ckw rts abziehen 4 Unterbrechen Sie die Verbindung A zur UV Lampe 5 Schrauben Sie den Befestigungsring B los entnehmen Sie den Quarzzylinder D und die gebrauchte UV Lampe und entfernen Sie den O Ring E wie dargestellt 6 Setzen Sie den neuen Quarzzylinder der die neue UV Lampe enth lt ein BENUTZEN SIE BAUMWOLLHANDSCHUHE WENN SIE DIESE ELEMENTE ANFASSEN Der Zylinder sollte auf einer Feder aufsitzen die f r die automatische Zentrierung in der korrekten Position sorgt 7 Setzen Sie den O Ring E wieder ein plazieren Sie den Druckring C in seine Position und schrauben Sie den Befestigungsring B fest um den Einsatz zusammenzuhalten 8 Schlie en Sie die UV Lampe an Anschlu A 9 Setzen Sie den r ckw rtigen Teil wieder ein schlie en Sie den Netzste
8. f rable d effectuer cet change le soir pour pouvoir laisser le Q PAK se r hydrater pendant la nuit e Remplacement du filtre final MILLIPAK 40 Figure 8 1 Mettre le MILLI Q 185 PLUS en mode STANDBY 2 Appuyer sur les languettes H du capot G pour retirer le capot et le MILLIPAK 3 Tirer sur le capot pour le dessolidariser du MILLIPAK 4 D visser le MILLIPAK usage 5 Installer le MILLIPAK neuf comme d crit dans le chapitre INSTALLA TION e Remplacement de la lampe U V Figure 9 Le capot arri re de l appareil doit tre d mont Dans le cas d un montage mural le MILLI Q 185 PLUS doit tre enlev de son support 1 Mettre l appareil hors tension et d brancher le cordon secteur 2 D visser le bouton molet voir figure 1 L et eventuellement l crou de la tige du montage mural voir figure 1 K si elle existe 3 Enlever le capot arri re en le glissant vers l arri re ENTRETIEN 9 4 D brancher le connecteur A de la lampe U V 5 D visser la bague de serrage B retirer le tube de quartz D la lampe U V usag e et le joint torique E 6 Mettre en place le nouveau tube de quartz contenant la lampe U V neuve UTILISER DES GANTS POUR MANIPULER CES ELEMENTS Le tube repose sur un ressort qui le centre automatiquement 7 Changer le joint torique E placer la bague d appui C et visser la bague de serrage B 8 Connecter la lampe U V connecteur A 9 R installer le cap
9. hrend der 15 min tigen Rezirkulation Wasser an der Entnahmestelle austritt 4 WARTUNG e Wartungshinweise Haufigkeit Ma nahme Ersetzen Sie das Q Pak Aufbereitungsmodul und den Millipak 40 Endfilter Wenn die Anzeige EXCHANGE PAK aufleuchtet oder wenn der Widerstand nach einigen Minuten Rezirkulation keine 18 2 MQ cm erreicht Einmal im Jahr oder wenn die Anzeige UV nicht mehr aufleuchtet Ersetzen Sie die UV Lampe Wenn die Flie rate durch den Endfilter zu gering wird Ersetzen Sie den Millipak 40 Endfilter Wurde der endfilter erst vor kurzem eingebaut berpr fen Sie die Qualit t des Speisewassers zum MILLI Q 185 PLUS System e Austausch des Q Pak Aufbereitungsmoduls 1 Bringen Sie das MILLI Q 185 PLUS System in den STANDBY Modus SCHALTEN SIE DAS SYSTEM NICHT AUS 2 L sen Sie den Q Pak Feststellhebel siehe Abbildung 1 F 3 Ziehen Sie das gebrauchte Q Pak heraus 4 Bauen Sie das neue Q Pak wie im Kapitel INSTALLATION beschrieben ein Hinweis Vorzugsweise wird der Austausch am Nachmittag oder Abend vorgenommen damit das Q Pak im System ber Nacht quellen kann e Austausch des Millipak 40 Endfilters Abbildung 8 1 Bringen Sie das MILLI Q 185 PLUS System in den STANDBY Modus 2 Dr cken Sie auf die beiden Laschen H an der Entnahmeabdeckung G um die Abdeckung und den Millipak abnehmen zu k nnen 3 Ziehen Sie an der Abdeckung um sie von dem Millipak zu
10. 1 K se montato a muro Rimuovere il coperchio posteriore tirandolo Disconnettere il connettore A dalla lampada U V tirandolo Svitare l anello di serraggio B togliendo il tubo di quarzo D con la lampada U V Inserire il nuovo tubo di quarto USARE GUANTI DI COTONE PER MANEGGIARE IL TUBO Il tubo appoggia su di una molla che ne permette il corretto posizionamento Sostituire l O ring E porre l anello di tenuta C in posizione ed avvitare l anello di bloccaggio B per chiudere il tutto Connettere la lampada U V connettore A 10 MANUTENZIONE 9 Reinserire il coperchio posteriore il cavo di alimentazione e accendere il sistema Verificare il corretto funzionamento della valvola U V la spia luminosa della lampada U V deve rimanere fissa durante il modo OPERATE MISMA E RIPARAZIONE GUASTI e Tavola di ricerca e riparazione guasti Se l unit MILLI Q 185 PLUS mostra un funzionamento non corretto consultare la tavola sotto riportata Questa tavola serve di aiuto per diagnosticare la ragione del funzionamento incorretto del sistema Se ci non fosse sufficiente contattare il Servizio di Assistenza Tecnica presso la filiale pi vicina La lista degli indirizzi alla fine di questo manuale PROBLEMA CAUSA AZIONI CORRETTIVE La spia di accensione rimane spenta La spia EXCHANGE PACK lampeggia La spia EXCHANGE PACK a luce fissa La spia dell U V non si i
11. Funktion wenn das System Periodische Funktion des Systems wahrend des STANDBY Modus im STANDBY Modus ist Das System rezirkuliert das Wasser automatisch in jeder stunde fir 15 Minuten um eine entsprechend hohe Wasserqualit t wahrend der Nichtbenutzung aufrecht zu erhalten Die 5 min tige Rezir kulationsphase beginnt 45 Minuten nachdem das System in den STANDBY Modus geschaltet wurde Danach rezirkuliert das System jede Stunde wenn es im STANDBY Modus steht Zus tzlich wird die Rezirkulation bei jedem Einschalten aktiviert BETRIEB 5 e Zusatzliche Anzeigen Anzeige Status des MILLI Q 185 PLUS Systems TEST INCORRECT Wird angezeigt wenn das Ergebnis des Autotests bei lt 14 MQ cm oder gt 16 MQ cm liegt Siehe Kapitel STORUNGSBESEITIGUNG BATTERY Die Batterie des PC Board ist entladen Die gespeicherten Daten gingen verloren als das System ausgeschaltet wurde Siehe Kapitel STORUNGSBESEITIGUNG EXCHANGE PAK Leuchtet auf wenn das Q Pak ausgewechselt werden sollte Siehe Kapitel WARTUNG Leuchtet st ndig wenn das Q Pak nicht eingebaut ist oder nicht korrekt in der Halterung sitzt Siehe Kapitel STORUNGSBESEITIGUNG U V Leuchtet f r 30 Sekunden auf wenn die UV Lampe eingeschaltet wird Aufheizen der Lampe Leuchtet st ndig wenn die UV Lampe in Betrieb ist und ihre Effizienz ein Optimum erreicht hat e Tastatureingaben Die Tastatur gestattet dem Verwender den Betriebsmodus des Systems zu
12. INTERRUPTOR GENERAL EN OFF 2 Baje la aleta gris de sujeci n F del equipo oprimiendo para ello la zona marcada PUSH 3 Extraiga el bloque QPAK del equipo 4 Instale un bloque QPAK nuevo siguiendo lo indicado en el cap tulo 2 INSTALACI N Antes de obtener agua proceda a la purga del bloque QPAK sin filtro Millipak en el punto de uso ver secci n Puesta en marcha en el cap tulo 3 OPERACION NOTA Es recomendable realizar esta sustituci n al final de la jornada de trabajo para permitir la purga la rehidrataci n nocturna y la nueva purga del bloque QPAK chapter e Sustituci n del filtro final Millipak figura 8 Si adem s del Millipak ha de sustituir el bloque QPAK realice siempre primero la sustituci n del bloque QPAK ver apartado anterior 1 Sit e el equipo en posici n de espera 2 Presione las aletas laterales H de la visera de protecci n G del punto de uso y extraiga la visera con el Millipak usado 3 Separe la visera del Millipak usado 4 Desenrosque el Millipak usado del adaptador del punto de uso 5 Instale un nuevo Millipak ver secci n Instalaci n y purga del filtro final Millipak en el cap tulo 3 OPERACION MANTENIMIENTO 9 e Sustituci n de la l mpara U V figura 9 Para esta operaci n debe abrir la cubierta trasera del equipo Si ste est montado en la pared ser necesario separarlo de la escuadra de montaje mural LA LAMPARA UV NUEVA NO DEBE TOCARSE DIRECTAMENT
13. Kit de remplacement de la lampe UV CFMQ 185 01 ACCESSOIRES R gulateur de pression pour l eau d entr e ZFMQ 000 PR Dispositif pour montage mural ZFMQ 00W MB GUIDE D ACHAT 17 18 GUIDE D ACHAT DEUTSCH e Inhaltsangabe Inhaltsangabe Kapitel 1 Einleitung Allgemeine Beschreibung Beschreibung der Funktionen FlieBschema Spezifikationen Kapitel 2 Installation Lieferumfang Montage des MILLI Q 185 PLUS Systems Installation Einbau des Q Pak Aufbereitungsmoduls Kapitel 3 Betrieb Standardbetriebsfunktionen Zus tzliche Anzeigen Tastatureingaben Elektrische Anschl sse Inbetriebnahme Einbau des Millipak 40 Endfilters Wasserentnahme Kapitel 4 Wartung Wartungshinweise Austausch des Q Pak Aufbereitungsmoduls Austausch des Millipak 40 Endfilters Auswechseln der UV Lampe ND O NN NO O O Un I Co Co CO CO O O O O Kapitel 5 St rungsbeseitigung Ubersichtstabelle Kapitel 6 Anhang Anhang 1 Auswechseln der Hauptsicherung Anhang 2 Sicherungswechsel auf der Hauptplatine Anhang 3 Auswechseln der Sicherung f r die UV Lampe Kapitel 7 Bestellinformationen Am Ende der Bedienungsanleitung Kapitel 8 Abbildungen Kapitel 9 Zus tzliche Informationen Technische Hinweise Gew hrleistung EINLEITUNG e Allgemeine Beschreibung Das MILLI Q 185 PLUS System wurde speziell zur Herstellung ultrareinen Wassers mit dem niedrigsten Gehalt an Organika der derzeit erreic
14. MILLIPAK sur le raccord femelle C du point de soutirage du MILLI Q 185 PLUS S assurer que l vent D est accessible 3 Appuyer sur le bouton OPERATE STANDBY pour mettre l appareil en mode de production Mettre la vanne 3 voies sur la position PRODUCTION A Purger l air contenu dans le filtre MILLIPAK en d vissant l g rement le bouchon de l vent E UTILISATION 7 Lorsque l eau s coule et que la poche d air a disparu resserrer le bouchon de purge Placer la vanne 3 voies sur la position RECIRCULATION et mettre l appareil en mode STANDBY Ins rer le filtre MILLIPAK dans le clip F du capot de protection G Monter le MILLIPAK et son capot sur le MILLI Q 185 PLUS en pres sant l g rement les languettes H situ es de chaque c t du capot et en les ins rant dans les 2 fentes J pr vues cet effet Le MILLI Q 185 PLUS est alors pr t fonctionner e Soutirage de l eau 1 Appuyer sur le bouton OPERATE STANDBY voir figure 1 1 pour mettre l appareil en mode de production Apr s 6 secondes le voyant U V voir figure 1 G clignote Attendre encore 30 secondes que le voyant soit allum et que la r sistivit atteigne 18 2 MQ cm avant de soutirer de l eau Cette temporisation permet la lampe d atteindre sa temp rature optimum de fonction nement Soutirer l eau n cessaire votre application en positionnant la vanne 3 voies voir figure 1 D sur PRODUCTION Re
15. Temperatura alla quale vien e compensata la misura della resistivit Visualizza il risultato dell auto test automatico Visualizza la resistivit dell acqua prodotta Visualizza la temperatura dell acqua all uscita dal Q PAK Funzionamento periodico del sistema durante il modo STANDBY Il sistema ricircoler l acqua automaticamente per 15 minuti ogni ora in modo da mantenere costante la qualit dell acqua durante i periodi di non utilizzo 15 minuti di RECIRCOLO iniziano 45 minuti dopo che il sistema stato posizionato in modo STANDBY Inoltre il modo RECIRCULATION si attiva ogni qual volta il sistema viene posto su ON FUNZIONAMENTO 5 e Visualizzazioni addizionali VISUALIZZAZIONE STATO DEL MILLI Q 185 PLUS PRODUCT XX MQ x cm Il visualizzatore indica che il valore della resistivit fuori scala Vedi il capitolo RICERCA E RIPARAZIONE GUASTI TEST INCORRECT Visualizzato quando il risultato dell Auto test lt di 14 MQ x cm o gt di 16 MQ x cm Vedere il capitolo Ricerca e riparazione guasti BATTERY La batteria sulla scheda PC scarica dati memorizzati quando il sistema stato spento sono persi Vedere il capitolo Ricerca e riparazione guasti EXCHANGE PACK Lampeggia quando necessario sostituire il Q PAK Vedere il capitolo Manutenzione Luce fissa quando il Q PAK non in sede o mal posizionato Vedere il capitolo Ricerca e riparazione guasti UV Lampeggia per 30 secondi q
16. accessi ble 3 Press the OPERATE STANDBY button to put the system in OPERATE mode Turn the 3 way valve to the PRODUCTION position OPERATION 7 Purge the air contained in the MILLIPAK 40 with water by slightly unscrewing the vent cap E When water exits the vent and the air pocket has disappeared retighten the vent cap Place the 3 way valve in the RECIRCULATION position and put the system in the STANDBY mode Insert the MILLIPAK filter into the clip F of the point of use cover G Install the Millipak filter and the point of use cover on the MILLI Q 185 PLUS by lightly pressing the tabs H situated on each side of the cover and inserting these tabs in the two grooves J intended for this purpose The MILLI Q 185 PLUS is now ready for use e Withrawing water 1 Press the button OPERATE STANDBY figure 1 I to put the system in the OPERATE mode After 6 seconds the U V indicator light figure 1 G should flash Wait a further 30 seconds until the indicator light is continously illuminated and the resistivity of the water has reached 18 2 MQ cm before drawing water This delay allows the lamp to reach its optimum temperature Withdraw water now by turning the 3 way valve figure 1 D to the PRODUCTION position 8 OPERATION 4 To stop drawing water turn the 3 way valve back to the RECIRCULATION position Press the OPERATE STANDBY button to put the system in the STANDB
17. and automatic OPERATING MODE DISPLAY ACTIVATION STATUS OF MILLI Q 185 PLUS STANDBY TEMPERATURE 25 C TEST MQ cm PRODUCT MQ cm TEMPERATURE C RECIRCULATION Press OPERATE STANDBY button when system is in OPERATE mode Press button TEMPERATURE when the system is in the STANDBY mode Press button OPERATE STANDBY when system is in STANDBY mode Display appears automatically 4 secs after having pressed the OPERATE STANDBY button when the system has been in STANDBY mode This display comes after the Auto test display Press the button TEMPERATURE while the system is in the OPERATE or RECIRCULATION mode Automatic function when system is in STANDBY mode The system is in the STANDBY mode and is not producing purified water Display of the reference TEMPERATURE 25 C Temperature compensated measurement at 25 C Display of automatic self test result to verify system calibration 15 1 MQ cm displayed for 4 secs Display of the product water resistivity Display of the product water temperature at the Q PAK outlet Periodic function of the system during the STANDBY mode The system will recirculate water automatically for 15 minutes every hour in order to maintain water quality during periods of non use The 15 mn RECIRCULATION period begins 45 mn after the system is placed in STANDBY mode and thereafter once every hour while the unit is in STANDBY In addi
18. d achat En fin de document Chapitre 8 Figures Chapitre 9 Informations compl mentaires Assistance technique Garantie 11 11 15 15 l INTRODUCTION e G n ralit s Le MILLI Q 185 PLUS a t con u pour produire de l eau ultrapure pur e des mati res organiques partir d eau osmos e ou distill e L eau produite d un d bit nominal instantan de 1 5 mn sera utilis e pour toutes les applications critiques o la quantit de mati res organiques la plus faible possible est souhait e Les principaux constituants du MILLI Q 185 PLUS figure 1 sont A Un pack de purification de l eau Q PAK 1 B Un point de soutirage prot g C Un filtre final 0 22 um MILLIPAK 40 D Une vanne 3 voies de soutirage E Un panneau de contr le F Une poign e de verrovillage du pack G Des indicateurs lumineux H Un afficheur cristaux liquides I Un clavier J Un raccord pour l alimentation en eau K Un bouchon fermant le trou de passage de la tige utilis e pour le montage mural L Un crou molet verrouillant le capot arri re M Un connecteur femelle de raccordement du contr le distance N Une prise secteur O Un porte fusibles P Un interrupteur marche arr t Q Un dissipateur de chaleur e Principe de fonctionnement Une pompe pousse l eau d alimentation pr purifi e osmos e ou distill e le long d une source UV Ultra Violet faible longueur d on
19. document Chapter 8 Figures Chapter 9 Additionnal information Technical assistance Warranty 15 15 15 15 17 1 INTRODUCTION General description The MILLI Q 185 PLUS has been developed specifically to produce Ultrapure water with the lowest level of organics currently attainable This water quality can be produced using a laboratory grade feed water prepurified by Reverse Osmosis or distillation to feed the system The system is designed to produce up to 1 5 litres minute of Ultrapure water on demand This water quality should be used for all critical applications requiring the lowest levels of organics e g Critical H P L C G C M S Langmuir Blodgett monolayers 1 C The MILLI Q 185 PLUS System main components are shown on figure 1 as follows A Water purification module Q PAK B Protected point of use C Point of use final filter 0 22 um membrane MILLIPAK 40 unit D Point of use 3 way valve E Control panel F Q PAK locking handle G Indicator lights H Liquid Crystal Display I Keyboard J Feed water inlet connection K Removeable plug blocking the socket for the wall mounting bracket arm L Knurled screw locking rear cabinet in place M Female Jack socket for connection of remote control device N Power inlet mains cord O Main fuse holder P ON OFF switch Q Heat sink e Description of function The prepurified feedwater Reverse Osmosi
20. hora Por otra parte si la v lvula de tres v as quedara en la posici n PRODUCTION en lugar de El MILLI Q 185 PLUS est ya listo para su uso recircular el agua inundar a su laboratorio a raz n de 90 litros hora e Obtenci n de agua de alta pureza figura 1 1 Presione la tecla OPERATE STANDBY 1 para situar el equipo en operaci n 2 Transcurridos dos segundos el piloto UV comenzar a parpadear mientras la resistividad del agua ir subiendo en la pantalla Antes de obtener agua espere unos 30 segundos hasta que el piloto UV luzca continuamente y a que la resistividad alcance los 18 2 MQ cm Esta breve espera permite que la l mpara U V alcance su r gimen ptimo de funcionamiento 8 OPERACION 4 MANTENIMIENTO e Calendario de mantenimiento FRECUENCIA ACCION Cuando se encienda el piloto EXCHANGE PACK o cuando la resistividad sea inferior de 18 MQ tras varios minutos de recirculaci n Anualmente o cuando deje de lucir el piloto UV Cuando el caudal de producci n sea muy bajo Sustituir el bloque de purificaci n QPAK y el filtro final Millipak Sustituir la l mpara U V Sustituir el filtro final Millipak Si esto ocurre con un Millipak nuevo verifique la calidad del agua que alimenta al MILLI Q 185 PLUS e Sustituci n del bloque de purificaci n QPAK figura 1 1 Presione la tecla OPERATE STANDBY para situar el equipo en modo de espera NO PONGA EL
21. instale sobre ella el adaptador E Corte el tubo C a la longitud necesaria para que quede recto sin bucles longitud lt 3 m 2 Extraiga el tap n protector B del acceso de entrada marcado INLET D presionando para ello el collar n A mientras tira del tap n 3 Conecte un extremo del tubo que ha cortado C al acceso de entrada marcado INLET K insertando para ello el tubo a fondo en el orificio Tire del tubo para comprobar el ajuste 4 La toma de agua pretratada debe terminar en una rosca macho de 1 2 pieza no incluida con el equipo Cubra esta rosca macho con cinta de Teflon y enrosque sobre ella el adaptador con rosca hembra de 1 2 componente E figura 3 A continuaci n conecte el otro extremo del tubo C a dicho adaptador INSTALLACION 3 Para agua pretratada tomada de una linea presurizada 1 Si la presi n de la l nea es superior a 1 bar instale a continuaci n de la llave de corte un regulador de presi n referencia ZFMQOOOPR Conecte el extremo del tubo C a la salida del regulador de presi n e Instalaci n del bloque de purificaci n QPAK figura 6 Baje la aleta gris de sujeci n F del equipo oprimiendo para ello la zona marcada PUSH Extraiga los tapones protectores A Desembale el bloque QPAK y extraiga los tapones B de los dos adaptadores Humedezca las juntas C de dichos adaptadores con unas gotas de agua Oriente el QPAK con los dos adaptadores hacia ar
22. la pantalla indica TEMPERATURE gt 36 C y localice ese problema en esta misma tabla Si acaba de conectar el equipo a la red ap guelo interruptor principal en OFF durante dos segundos y vuelva a encenderlo Si la bater a est realmente descargada deje el equipo en STANDBY durante 48 horas para cargarla Despu s sit e el interruptor principal en OFF durante 2 segundos y vuelva a encenderlo para borrar el mensaje BATTERY DIAGNOSTICO Y SOLUCION DE PROBLEMAS 11 PROBLEMA CAUSA SOLUCION Pantalla indicando TEST INCORRECT tras el auto test Pantalla indicando PRODUCT XX X MQ cm Pantalla indicando TEMPERATURE gt 35 C durante el modo de operaci n producci n o recirculaci n Calibraci n incorrecta de temperatura Calibraci n incorrecta de resistividad Presencia de aire en el circuito de medicion Fallo en la calibraci n TEST INCORRECT La temperatura del agua ha llegado a 36 C y ha de bajar a 35 C para que este mensaje desaparezca y la l mpara U V vuelva a funcionar Las posibles causas son el agua pretratada est demasiado caliente o el MILLI Q 185 PLUS ha sido dejado durante mucho tiempo en modo de operaci n sin sacar agua de l El agua pretratada est demasiado caliente Con el equipo en modo de espera presione la tecla TEMPERATURE Si aparece TEMPERATURE 25 C el calibrado es correcto ver m s abajo Si aparece otro valor p
23. la posici n PRODUCTION OPERACION 7 4 Desenrosque ligeramente el tap n de venteo E del Millipak para 3 Para obtener agua sit e un recipiente en la repisa del equipo bajo desalojar el aire de su interior el punto de uso y sit e la v lvula de tres v as D en la posici n PRODUCTION 5 Cuando comience a salir agua por el orificio del venteo y haya desaparecido la burbuja de aire del interior del filtro cierre el 4 Para detener la producci n de agua sit e la v lvula de tres v as en tap n la posici n RECIRCULATION Presione de nuevo la tecla OPERATE STANDBY para dejar el equipo en espera 6 Sit e la v lvula de tres v as en la posici n RECIRCULATION Sit e el equipo en modo de espera STANDBY NOTA mientras no utilice el equipo d jelo siempre en espera con el mensaje STANDBY en pantalla y la v lvula detres v as en RECIRCULATION 7 Inserte el filtro Millipak en el alojamiento interior F de la visera de Nunca lo apague por el interruptor principal ni lo desconecte de la red protecci n G del punto de uso a no ser que vaya a trasladarlo o a realizar alguna operaci n de mantenimiento que as lo precise 8 Instale la visera sobre el punto de uso del equipo presionando para ello las aletas H situadas a ambos lados de la visera e El equipo necesita corriente para realizar la recirculaci n autom tica insert ndolas en las muescas J que hay en el equipo intermitente del agua 15 minutos de cada
24. la siguiente tabla como primer recurso para diagnosticar la causa del problema Si esto no fuera suficiente p ngase en contacto con el Servicio T cnico de Millipore la lista completa de oficinas Millipore est al final de este manual PROBLEMA CAUSA SOLUCION Equipo sin corriente piloto POWER apagado Piloto EXCHANGE PACK parpadeando Piloto EXCHANGE PACK encendido continuamente Piloto UV apagado durante el modo de operaci n producci n o recirculaci n Pantalla indicando BATTERY La toma mural no recibe corriente El cable de corriente est mal conectado El fusible principal est fundido El fusible de la tarjeta electr nica est fundido El bloque QPAK debe sustituirse El bloque QPAK falta o no est bien conectado El fusible de la l mpara U V est fundido La l mpara U V est agotada o mal instalada La temperatura del agua es demasiado alta La bater a est descargada Compruebe la red el ctrica Compruebe el cable Sustituya el fusible principal ap ndice 1 Sustituya el fusible de la tarjeta electr nica ap ndice 2 Sustituya el bloque QPAK vea el cap tulo 4 MANTENIMIENTO Conecte correctamente el bloque QPAK vea el cap tulo 2 INSTALACION Sustituya el fusible de la l mpara U V situado en la tarjeta electr nica ap ndice 3 Sustituya la l mpara U V vea el cap tulo 4 MANTENIMIENTO Compruebe si
25. la valvola a 3 vie A RECIRCULATION PRODUCTION su PRODUCTION Mettere un contenitore B sotto l uscita dell unit filtrante MILLIPAK 40 Accendere il sistema su ON per mezzo del pulsante ON OFF posto sul retro vedi figura 1 P Il visualizzatore ora mostra RECIRCULATION Se appare BATTERY spegnere il sistema per 2 secondi e poi riaccenderlo Se il sistema alimentato da una linea in pressione attraverso un regolatore di pressione regolare la pressione in uscita al regolatore tra 0 5 e 1 bar quando il MILLI Q 185 PLUS in produzione valvola a 3 vie A su PRODUCTION con acqua che esce dall uscita C 7 Lasciare acceso il sistema permettendo all acqua di uscire da C Ci consente l espulsione dell aria dal sistema e dal Q PAK Aprire e chiudere pi volte la valvola a 3 vie Dopo avere scaricato 5 7 litri di acqua commutare la valvola a 3 vie A Sulla posizione RECIRCULATION Premere due volte il pulsante OPERATE STANDBY per porre il sistema in modo STANDBY Se possibile lasciare il sistema tutta la notte in questa posizione in modo da reidratare perfettamente le resine contenute nel Q PAK Al mattino successivo premere il pulsante OPERATE STANDBY viene visualizzato per 4 secondi TEST MQ x cm quindi 2 secondi pi tardi l indicatore della lampada ad U V inizia a lampeggiare mentre la lampada si riscalda Alla fine dei 30 secondi di lampeggiamento l indicatore luminoso mostra u
26. linguetta e spingendo verso il basso Rimuovere i tappi di protezione A 2 Rimuovere i tappi di protezione B sul Q PAK 3 Inumidire i due O Ring C con alcune gocce d acqua 4 Posizionare il Q PAK nella sua cavit Tenere fermo il MILLI Q 185 PLUS D e spingere in sede il Q PAK E se necessario muoverlo leggermente 5 Riportare in posizione iniziale la leva di bloccaggio F 4 INSTALLAZIONE 3 FUNZIONAMENTO e Modi Operativi Standard Il MILLI Q 185 PLUS visualizza parecchi modi operativi Alcuni possono essere attivati dalla tastiera mentre gli altri sono preprogrammati ed automatici VISUALIZZAZIONE DEL ATTIVAZIONE STATO DEL MILLI Q 185 PLUS MODO OPERATIVO STANDBY Premere il pulsante OPERATE STANDBY Il sistema in modo STANDBY e non produce acqua TEMPERATURE 25 C TEST MQ x cm PRODUCT C TEMPERATURE C RECIRCULATION quando il sistema in modo OPERATE Premere il pulsante TEMPERATURE quando il sistema in modo STANDBY Premere il pulsante OPERATE STANDBY quando il sistema in modo STANDBY La visualizzazione appare automaticamente 4 sec dopo avere premuto il pulsante OPERATE STANDBY quando il sistema in modo STANDBY La visualizzazione avviene dopo l Auto test Premere il pulsante TEMPERATURE mentre il sistema in modo OPERATE o RECIRCULATION Funzionamento automatico quando il sistema in modo STANDBY Visualizza TEMPERATURE 25 C
27. steuern und eine Anzahl von vorgegebenen Parametern anzuzeigen die f r das korrekte Funktionieren des Systems Voraussetzung sind Bezeichnung de Tasten Funktion OPERATE STANDBY Dr cken der Taste aktiviert hinterein ander den OPERATE und STANDBY Modus TEMPERATURE W hrend des STANDBY Modus Dr cken der Taste w hrend des STANDBY Modus f hrt zur Anzeige der Referenztemperatur 25 C Wird die Taste anschlieBend losgelassen verschwindet die Temperaturanzeige nach 3 Sekunden W hrend des RECIRCULATION Modus oder OPERATE Modus Bei Dr cken der Taste w hrend dieser Modi wird die im System vorherrschende Produktwassertemperatur angezeigt Nach Loslassen des Knopfes verschwindet die Temperaturanzeige innerhalb von 3 Sekunden 6 BETRIEB e Elektrische Anschl sse an der R ckseite des Systems REMOTE STANDBY Anschlu dieser Anschlu gestattet es das MILLI Q 185 PLUS System mittels einer externen Fernbedienung zu steuern REMOTE STANDBY OPERATE Modus F r weitere Informationen betreffend dieser Funktion setzen Sie sich bitte mit dem Technischen Service Ihrer Millipore Niederlassung in Verbindung e Inbetriebnahme Abbildung 7 1 Stellen Sie sicher da das Q Pak korrekt eingebaut ist und alle Verbindungen korrekt hergestellt wurden 2 ffnen Sie die Speisewasserzufuhr 3 Stellen Sie das Entnahme 3 Wege Ventil A von RECIRCULATION PRODUCTION auf die Position PRODUCTION 4 Stellen Sie einen Auffa
28. technique Millipore si cette valeur est differente Si la temp rature est bien calibr e en appuyant sur le bouton OPERATE STANDBY TEST 15 MQ cm 1 MQ doit tre affich Appeler le service Technique MILLIPORE si cette valeur est hors sp cification Purger le Q PAK et le circuit de mesure en ouvrant la vanne de puisage Calibrer le circuit de mesure voir ci dessus Mettre l appareil en mode STANDBY lorsqu il n est pas utilis Soutirer de l eau pour faire baisser la temp rature S il n est pas possible de la r duire enlever le cavalier E sur le circuit imprim pour mettre cette fonction hors service Contacter le service de maintenance MILLIPORE V rifier l alimentation en eau Appeler le service de maintenance MILLIPORE Changer le Q PAK Voir chapitre ENTRETIEN 12 MAINTENANCE DEFAUT CAUSES REMEDES Pas de d bit d eau en production Faible d bit d eau en production Vanne d alimentation en eau ferm e Electrovanne d entr e d fectueuse Pompe d samorc e D faut d alimentation en eau Poche d air dans le filtre MILLIPAK 40 Filtre MILLIPAK 40 colmat Ouvrir la vanne Appeler le service de maintenance MILLIPORE La pompe peut aspirer lorsqu elle a t amorc e Introduire de l eau dans l appareil en l alimentant par gravit ou sous pression V rifier l alimentation en eau de l appareil Pression d alimentation section et longueur des tuyaux
29. w hrend die Lampe aufgeheizt wird Nach 30 Sekunden leuchtet die Anzeigelampe kontinuierlich Entnehmen Sie nun 2 3 Liter Wasser Stellen Sie das System zur ck auf den STANDBY Modus durch einmaliges Dr cken der OPERATE STANDBY Taste e Einbau des Millipak 40 Endfilters Abbildung 8 Nach vollst ndiger Entl ftung und Quellung des Q Paks ber Nacht kann der Millipak Endfilter eingebaut werden b Umwickeln Sie das Gewinde A der Millipak Filtereinheit mit 2 3 Lagen Teflonband um eine Wasserabdichtung zu erreichen 2 Schrauben Sie die Millipak Filtereinheit in den Innengewindeanschlu C der Entnahmestelle des MILLI Q 185 PLUS Systems Stellen Sie sicher da die Entl ftung D zug nglich ist BETRIEB 7 3 Dr cken Sie die OPERATE STANDBY Taste um das System in den OPERATE Modus zu stellen Drehen Sie das 3 Wege Ventil auf PRODUCTION 4 Entl ften Sie die Millipak 40 Filtereinheit indem Sie die Entl ftungskappe E leicht ffenen 5 Sobald Wasser aus der Entl ftung austritt und eingeschlossene Luft verschwunden ist ziehen Sie die Entl ftungskappe wieder an 6 Stellen Sie das 3 Wege Ventil in die Position RECIRCULATION und stellen Sie das System in den STANDBY Modus 7 F hren Sie den Millipak Endfilter in den Halter F der Entnahmestellenabdeckung G ein 8 Bauen Sie den Millipak Endfilter und die Entnahmeabdeckung am MILLI Q 185 PLUS System durch leichtes Dr cken der Laschen H die sich auf be
30. 5 nm 254 nm ausgesetzt wird Dieses leitet die Oxidation von gel sten organischen Verbindungen ein die nach dem Vorreinigungsproze Umkehrosmose oder Destillation noch im Wasser verblieben sind Die UV Bestrahlung hat auch eine bakterizide Wirkung Das UV behandelte Speisewasser wird dann durch das Q Pak Aufbereitungsmodul gef hrt in dem die ionischen Verbindungen entfernt werden Ein eingebautes 3 Wege Ventil gestattet die Rezirkulation des Wassers bis die gew nschte Wasserqualit terreicht ist Nach Erreichen der gew nschten Wasserqualit t erlaubt die Drehung des 3 Wege Ventils die Passage des Wassers durch den Millipak 40 Endfilter zur Entnahmestelle e Flie schema Eine schematische Darstellung des Betriebes des MILLI Q 185 PLUS Systems zeigt die Abbildung 2 wie folgt A Einla ventil B Pumpe C UV Lampe mit Geh use D Q Pak Wasseraufbereitungsmodul E Widerstandsme zelle zur Messung der Wasserqualit t F 3 Wege Ventil G Millipak 40 Endfilter 0 22 um H Druckhalteventil EINLEITUNG 1 e Spezifikationen Abmessungen H he Breite Tiefe Betriebsgewicht 495 mm 19 5 in 297 mm 11 7 in 433 mm 17 in 17 kg Elektrische Spezifikationen 230 V 50Hz 180 VA 1 Amp slow blow Sicherung Hydraulische Spezifikationen Speisewasserzuleitung Speisewasserdruck Speisewasserflie rate u erer Durchmesser 8 mm Maximale L nge 3 m Minimum 0 03 bar 0 5 psi Maximal 1 0 b
31. 71 80 GERMANY Millipore GmbH Postfach 6147 D 65731 Eschborn Tel 06196 494 0 Telex 40 72 704 mil d FAX 06196 482237 HONG KONG Millipore China Ltd Millipore Asia Ltd 1401 Cityplaza 4 12 Taikoo Wan Road Hong Kong Tel 852 803 9111 Telex 33140 MWBHK HX FAX 852 513 0313 HUNGARY Millipore kft Andor ut 60 H 1119 Budapest Tel 36 11 66 86 74 Telex 20 25 55 FAX 36 11 81 29 59 INDIA Millipore India Pvt Ltd 50A 2nd Phase Ring Road Peenya Bangalore 560 058 Tel 812 394657 396320 Telex 845 5089 MLPR IN Cable Millipore FAX 812 396345 ITALY Millipore S p A Via Achille Grandi 23 I 20090 Vimodrone MI Tel 02 25078 1 Telex 312 284 milspa i FAX 02 2650324 Millipore S p A Via D Sansotta 100 1 001 44 Roma Tel 06 5203600 FAX 06 5295735 Millipore S p A P za S Croce 42 1 35123 Padova Tel 049 8803720 FAX 049 8803735 TECHNICAL INFORMATION JAPAN Nihon Millipore Ltd Dai 5 Koike Bldg 3 12 Kitashinagawa 1 Chome Shinagawa Ku Tokyo 140 Tel 03 3474 9111 Telex 24948 MILLIPOR J FAX 03 3474 9130 KOREA Millipore Korea Ltd 2 FL Soseok Building 157 21 Samsung Dong Kangnam Ku Seoul 135 090 Tel 82 2 5548305 FAX 82 2 5636253 MALAYSIA Millipore Asia Ltd Malaysia Branch B4 05 PJ Industrial Park Section 13 Jalan Kemajuan 46200 Petaling Jaya Selangor Tel 60 3 7571322 FAX 60 3 7571711 MEXICO Millipore S A de C V Avenida In
32. AIWAN Millipore Asia Ltd Unit 804 8 F Lotus Bldg 136 Jen Ai Road Sec 3 Taipei 10628 R O C Tel 886 2 7001742 FAX 886 2 7553267 U K and IRELAND Millipore U K Ltd The Boulevard Blackmoor Lane Watford Hertfordshire WD1 8YW Tel 0923 816375 Telex 24191 milpor g FAX 0923 818297 U S A Millipore Corporation P O Box 255 Bedford MA 01730 Tel Toll Free including Massachusetts 800 225 1380 In Western States Alaska 8 Hawaii 800 632 2708 In Puerto Rico 809 747 8444 In All Other Countries Millipore Intertech 397 Williams Street Marlborough MA 01752 9162 U S A Tel 508 624 8622 FAX 508 624 8630 TECHNICAL INFORMATION eWarranty Millipore Corporation Millipore warrants the products manufactured by itagainst defects in materials and workmanship when used in accordance with the applicable instructions for a period of one year from the date of shipment of the products MILLIPORE MAKES NO OTHER WARRANTY EXPRESSED OR IMPLIED THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE The warranty provided herein and the data specification and descriptions of Millipore products appearing in Millipore s published catalogues and product literature may not be altered except by express written agreement signed by an officer of Millipore Representations oral or written which are inconsistent with this warranty or such publications are not authorized and if given s
33. E CON LAS MANOS Is Sit e el interruptor principal figura 1 P en OFF y desconecte completamente el cable de entrada de corriente figura 1 N 2 Desenrosque el tornillo de cierre de la cubierta trasera figura 1 L y el tap n o clavija de fijaci n a la escuadra de montaje mural figura 1 K 3 Extraiga la cubierta posterior tirando de ella hacia atr s 4 Desconecte el adaptador A de la l mpara U V tirando de l hacia arriba 5 Desenrosque el anillo de cierre B y tome el tubo de cuarzo D la l mpara U V usada y la junta t rica E como muestra la figura 6 Extraiga la nueva l mpara U V de su envase sin tocarla con las manos UTILICE SIEMPRE GUANTES PREFERIBLEMENTE DE ALGOD N PARA MANIPULAR UNA L MPARA U V NUEVA El tubo de la l mpara debe apoyar sobre un muelle que ayudar a centrarlo 10 MANTENIMIENTO 7 Reponga la junta t rica E ajuste el anillo de presi n C y enrosque el anillo de cierre B con lo que el conjunto quedar cerrado 8 Conecte la l mpara U V clavija A 9 Reponga la cubierta trasera conecte el cable de entrada de cor riente y sit e el interruptor en ON Verifique el correcto funcionamiento de la l mpara U V UV debe lucir durante el modo de operaci n del equipo el piloto D niasuestico Y SOLUCION DE PROBLEMAS e Gu a de diagn stico y soluci n de problemas Si el MILLI Q 185 PLUS no funciona correctamente consulte inmediatamente
34. ION position and water flowing out of fitting C 7 Leave the system running allowing water to flow out of fitting C This will allow all the air to be purged from the system and the Q PAK Control the filling of the recipient by opening and closing the three way valve A a few times 8 After having drawn 5 7 litres of water via fitting C turn the 3 way valve A to the RECIRCULATION position Press the OPERATE STANDBY button twice to put the system into STANDBY mode If possible leave the system like this overnight to allow the Q PAK contents to fully rehydrate 9 The following morning press the OPERATE STANDBY button TEST MQ cm should be displayed for 4 seconds then 2 seconds later the UV indicator light should flash for 30 seconds while the lamp heats up At the end of this 30 second period the indicator light should be constantly illuminated Draw off 2 3 litres of water Put the system back into STANDBY mode by pressing once on the OPERATE STANDBY button e Installation of final filter MILLIPAK 40 0 22 um Figure 8 When the Q PAK has been completely purged of air and allowed to rehydrate overnight you can proceed to fit the MILLIPAK final filter 1 Cover the thread A of the MILLIPAK filter unit with 2 3 turns of Teflon tape in order to assure a watertight seal 2 Screw the MILLIPAK filter unit into the female fitting C at the point of use on the MILLI Q 185 PLUS Make sure that the vent D is
35. PLUS es el siguiente figura 2 A V lvula solenoide de entrada B Bomba C C mara de foto oxidaci n U V D Bloque de purificaci n QPAK E Sensor de resistividad del agua ultrapura F V lvula de tres v as G Filtro final Millipak H Valvula anti retorno INTRODUCCION e Especificaciones Dimensiones Altura Anchura Profundidad Peso en funcionamiento 495 mm 19 5 297 mm 11 7 433 mm 17 17 kg Especificaciones el ctricas 230 V 50 Hz 180 VA Fusible 1 A lento Especificaciones hidr ulicas Tubo de entrada de agua Longitud m xima 3 m Presi n de entrada de agua M ximo 1 0 bar 15 psi 8 mm D E M nimo columna de 0 3 m altura Caudal de entrada de agua 1 5 l min Rendimiento Caudal de producci n 1 51 min Carbono org nico total C O T Resistividad lt 5 ppb valor medio con agua pretra tada por smosis inversa determinado con ANATEL A 100P 18 2 MQ cm 2 INTRODUCCION 2 INSTALLACION e Desembalado Al desembalar el MILLI Q 185 PLUS usted debe disponer de los siguientes componentes seg n se indica en la figura 3 A Equipo MILLI Q 185 PLUS B Cable de alimentaci n el ctrica C Visera de protecci n del punto de uso D Manual de operaci n y mantenimiento E Adaptador rosca hembra de 1 2 tubo de 8 mm e con filtro de rejilla F Rollo de cinta de Teflon para recubrimiento de piezas roscadas Art culos que
36. TION e D ballage Les diff rents composants fournis sont repr sent s sur la figure 3 et num r s ci dessous A MILLI Q 185 PLUS B Cordon secteur C Capot de montage du filtre MILLIPAK D Manuel d utilisation E Adaptateur 1 2 femelle tuyau 8 mm avec filtre tamis int gr F Ruban Teflon Command s par ment Pack de purification de l eau Q PAK G Filtre final 0 22 um Millipak 40 H G H Cat N CPMQKO5R1 e Mise en place du MILLI Q 185 PLUS Le MILLI Q 185 PLUS peut tre pos sur une paillasse ou fix au mur Dans le cas d un montage mural utiliser l querre de montage mural Cat N ZFMQ 00W MB et s assurer que le mur est capable de supporter le poids de l appareil La figure 4 vous montre la connectique d un MILLI Q 185 PLUS avec ses diff rentes alimentations NOTA La vanne d arr t le r gulateur de pression et son manom tre repr sent s sur la figure 4 ne sont pas fournis e Installation BRANCHEMENT DE L ARRIV E DE L EAU Figure 5 A partir d une cuve 1 Couper le tuyau d alimentation C la longueur d sir e lt 3 m 2 Retirer le bouchon de protection B de la connection INLET D en appuyant sur le collier A 3 Connecter le tuyau d alimentation C l entr e INLET en l ins rant fermement dans le raccord puis v rifier que la connection est bonne en tirant plusieurs fois sur le tuyau 4 Connecter le tuyau la vanne de sortie de cuve qu
37. Y mode NOTE When you do not require water leave the MILLI Q 185 PLUS in the STANDBY mode In order to maintain water quality during non use periods the system will automatically recirculate water for 15 minutes every hour during STANDBY mode The display will show RECIRCULATION during this period During STANDBY mode make sure that the 3 way valve is in the RECIRCULATION position to avoid water flowing out of the point of use during the 15 min RECIRCULATION 4 MAINTENANCE e Maintenance schedule FREQUENCY ACTION When the indicator light EXCHANGE PAK flashes or when the resistivity no longer reaches 18 2 MQ cm after a few minutes of recirculation indicator light no longer lights up When the flow rate through the final filter becomes unacceptably low Once a year or when the U V Replace the purification pack Q PAK and the final filter MILLIPAK 40 Replace the U V lamp Replace the MILLIPAK 40 final filter If this has only been in place a short time check the quality of the feedwater to the MILLI Q 185 PLUS unit e Replacement of Q PAK purification element 1 Put the MILLI Q 185 PLUS system in STANDBY mode DO NOT SWITCH OFF THE SYSTEM 2 Unlock the Q PAK retaining arm see figure 1 F 3 Pull out the used Q PAK A Install the replacement Q PAK as described in INSTALLATION chapter NOTE It is preferable to carry out this replacement in the afternoon or ev
38. a U V CFMQ18501 ACCESSORI Regolatore di pressione ZFMQOOOPR Staffa di montaggio a muro ZFMQOOWMB INFORMAZIONI PER L ORDINE 17 18 INFORMAZIONI PER L ORDINE FIGURES FIGURES 1 and 2 FIGURES Figure 2 Figure 1 FIGURES 3 4 and 5 Figure 4 FIGURE 6 Figure FIGURES 7 and 8 FIGURES 9 10 and 11 Figure 10 Figure 11 TECHNICAL INFORMATION e Technical assistance For futher information on Millipore products please contact your nearest Millipore subsidiary AUSTRALIA Millipore Australia Pty Limited A C N 001 239 818 Private Bag No 18 87 89 Mars Road Lane Cove N S W 2066 Tel Toll Free 008 222 111 In Sydney Area 02 428 7333 FAX 02 427 0611 AUSTRIA CENTRAL EUROPE C 1 S AFRICA MIDDLE EAST and GULF Millipore Ges m b H Hietzinger Hauptstra e 145 A 1130 Wien Austria Tel 43 1 877 8926 Telex 131464 miliv a FAX 1 877 1654 BALTIC REPUBLICS Millipore Oy Ruukinkuja 1 SF 02320 Espoo 32 Finland Tel 90 801 90 77 FAX 90 801 46 40 BELGIUM and LUXEMBOURG Millipore S A N V Rue de la Fus e 60 Raketstra
39. a temp rature de l eau est trop lev e Voir rubrique TEMPERATURE gt 35 C BATTERY est affich Batterie d charg e Mettre l appareil sous tension pendant plus de 48 h pour recharger la batterie Couper le secteur 2 secondes pour effacer l information BATTERY MAINTENANCE 11 DEFAUT CAUSES REMEDE TEST INCORRECT est affich apr s le test 15 MQ cm PRODUCT XX MQ cm est affich TEMPERATURE gt 35 C est affich pendant la production ou la recirculation TEMPERATURE lt 0 C ou TEMPERATURE gt C est affich e pendant la production La r sistivit de l eau n atteint pas 18 2 MQ cm apr s plusieurs minutes de recirculation Mauvaise calibration du circuit temp rature Mauvaise calibration du circuit r sistivit Pr sence d air dans le circuit de mesure D faut de calibration du circuit de mesure TEST INCORRECT La temp rature de l eau a d pass 36 C et doit redescendre 35 C pour autoriser l allumage de la lampe U V L appareil est rest trop longtemps en mode de production sans soutirage d eau La temp rature de l eau d entr e ou la temp rature ambiante est trop lev e La temperature de l eau d entr e est sup rieure 40 C La thermistance ou sa connexion est d fectueuse Le Q PAK est satur En mode STANDBY appuyer sur le bouton TEMPERATURE TEMPERATURE 25 C doit tre affich Appeler le service
40. aje aparece cuando el resultado del auto test es lt 14 MQ cm 6 gt 16 MQ cm Vea el cap tulo 5 DIAGNOSTICO Y SOLUCION DE PROBLEMAS La bater a interna est descargada y se ha perdido la informaci n almacenada en la memoria del equipo Vea el cap tulo 5 DIAGNOSTICO Y SOLUCION DE PROBLEMAS Encendido continuamente cuando el QPAK falta o no est bien conectado Vea el cap tulo 4 MANTENIMIENTO Parpadeando para indicar que el bloque QPAK debe cambiarse por otro Vea el cap tulo 5 DIAGNOSTICO Y SOLUCION DE PROBLEMAS Parpadea durante 30 segundos cuando se enciende la l mpara etapa de calentamiento Encendido continuamente cuando la l mpara est funcionando y su rendimiento es el ptimo Uso del teclado El teclado permite al usuario acceder a los valores preseleccionados y activar o modificar los modos operativos TECLA FUNCION OPERATE STANDBY Presionando esta tecla se alternan los modos de operaci n y de espera TEMPERATURE Presionando esta tecla cuando el sistema est en modo de espera aparece TEMPERATURE 25 C que es la temperatura de referencia para la lectura de resistividad ya que sta se presenta compensada a 25 C Presionando esta tecla cuando el sistema est en modo de operaci n aparece TEMPERATURE C que es la temperatura real del agua producida por el equipo En ambos casos el mensaje desaparece tres segundos despu s de soltar la tecla 6 OPERACION e Conexiones el ct
41. ar 15 psi 1 5 l min Leistung ProduktwasserflieBrate T O C Total Oxidisable Carbon 1 5 l min maximum lt 5 ppb typischer Wert nach Anatel A 100 P 2 EINLEITUNG 2 INSTALLATION e Lieferumfang Beim Auspacken des MILLI Q 185 PLUS Systems sollten Sie die in der Abbildung 3 gezeigten Gegenst nde vorfinden A MILLI Q 185 PLUS System B Netzkabel C Abdeckung f r Endfiltereinheit D Betriebsanleitung E Adapter 1 2 au en 8 mm Schlauchschnellverschlu mit eingebautem Edelstahlsieb F Teflonband Separat zu bestellendes Zubeh r G Q Pak Aufbereitungsmodul H Endfiltereinheit Millipak 40 0 22 um Zubeh r G H Kat Nr CPMQKOSRI e Montage des MILLI Q 185 PLUS Systems Das MILLI Q 185 PLUS System kann leicht auf einem Labortisch stehend oder an der Wand installiert werden Wenn Sie das System an eine Wand montieren m chten bestellen Sie bitte die Wandhalterung Kat Nr ZEMQ 00W MB und stellen Sie sicher da die Wand das Betriebsgewicht der Einheit 17 kg tragen kann Abbildung 4 zeigt den Anschlu de MILLI Q 185 PLUS systems mit verschiedenen Speisewasseroptionen Tank oder Druckleitung Hinweis Das Absperrventil in der Druckleitung der Druckminderer und das Manometer wie sie in Abbildung 4 gezeigt werden sind nicht im Lierferumfang enthalten e Installation SPEISEWASSERANSCHLUSS ABBILDUNG 5 Speisung aus einem Tank 1 Schneiden Sie den Speisewasserschla
42. at 60 B 1130 Bruxelles Brussel Tel 02 242 17 40 FAX 02 242 27 85 BRAZIL Millipore Ind stria e Com rcio Ltda Rua Prof Campos de Oliveira 430 CEP 04675 S o Paulo SP Tel 011 548 7011 Telex 11 57751 MILY BR FAX 011 548 7923 CANADA Millipore Canada Ltd 3688 Nashua Drive Mississauga Ontario L4V 1M5 Tel Toll Free 1 800 268 4881 In Toronto Area 416 678 2161 FAX 416 678 0882 CHINA People s Republic of Millipore China Ltd Suite 1101 1106 and 16 Asia Pacific Bldg No 8 Ya Bao Road Chao Yang District Beijin Postal Code 100020 Tel 86 1 5135114 5135116 7 5125992 51 26123 Telex 22685 NMLBJ FAX 86 1 5126113 Millipore China Ltd Room 615 China Hotel Office Tower Linhua Lu Guangzhou Postal Code 510015 Tel 86 20 686217 Millipore China Ltd Suite 2805 Union Building 100 Yan An Road E Shanghai 200002 Tel 86 21 3203856 FAX 86 21 3200236 CZECH REPUBLIC Millipore Austria Ges m b H Obchodn Zastoupen R canova 21 CS 169 00 Praha 6 Tel 42 2 35 02 27 42 2 35 23 75 FAX 42 2 35 02 27 42 2 35 23 75 DENMARK Millipore A S Baldersbuen 46 DK 2640 Hedehusene Tel 46 59 00 23 FAX 46 59 13 14 FINLAND Millipore Oy Ruukinkuja 1 SF 02320 Espoo Tel 90 801 90 77 FAX 90 801 46 40 TECHNICAL INFORMATION FRANCE Millipore S A BP 307 F 78054 Saint Quentin Yvelines Cedex Tel 1 30 12 70 00 Telex 698 371 F FAX 1 30 12
43. ated measurement at 25 C When the button is subsequently released the temperature display will disappear after 3 seconds During RECIRCULATION mode or OPERATE mode pressing this button during these modes the current product water temperature in the system is displayed when the button is subsequently released the temperature display will disappear after 3 seconds 6 OPERATION e Electrical connections at the back of system REMOTE STANDBY socket This inlet allows the MILLI Q 185 PLUS to be controlled from an external remote unit REMOTE STANDBY OPERATE modes Contact Millipore Technical Services for further information concerning the use of this function e Startup Figure 7 1 Verify that the Q PAK is correctly installed and that all connections have been correctly made 2 Open the feed water isolating valve 3 Put the point of use 3 way valve A RECIRCULATION PRODUCTION in the PRODUCTION position 4 Position a container B under the outlet fitting C for the MILLIPAK 40 filter unit 5 Switch the system ON by pressing the main ON OFF switch at the rear see figure 1 P The display should now show RECIRCULATION IF BATTERY appears switch the system OFF for two seconds then back ON 6 If the system is fed from a pressurized line via a pressure regulator adjust the exit pressure from the regulator between 0 5 and 1 bar when the MILLI Q 185 PLUS is in production 3 way valve A open in the PRODUCT
44. ature is correctly calibrated pressing OPERATE STANDBY button should cause TEST 15 0 MQ cm 1 MQ cm to be displayed Call MILLIPORE Technical Service if this value is out of specification Purge the air from Q PAK and measurement circuit by opening the point of use valve Calibrate measurement circuit See above Put the system in STANDBY mode when not in use Withdraw water from the system to help to decrease the temperature to allow the U V lamp to relight If it is not possible to reduce the feedwater temperature then remove jumper E on the P C Board to cancel this function Contact MILLIPORE Service Department Check feed water temperature and decrease it if it is elevated Call MILLIPORE Service department 12 TROUBLESHOOTING PROBLEM CAUSE REMEDIAL ACTION The resistivity of water in the system does not reach 18 2 MQ cm after several minutes of recirculation No water produced in OPERATE mode Low flow rate of water in OPERATE mode The Q PAK is exhausted Isolating valve on feedwater is closed Faulty inlet solenoid valve Pump running dry Lack of feedwater Air pocket build up in MILLIPAK 40 final filter MILLIPAK 40 final filter plugged Replace the Q PAK See MAINTENANCE chapter Open the feed isolating valve Call MILLIPORE Service Department The pump can pull in water only when it is primed Introduce water into th
45. cker an und schalten Sie das System auf ON Stellen Sie das einwandfreie Funktionieren der UV Lampe sicher Die Anzeigeleuchte UV sollte w hrend des OPERATE Modus brennen 10 WARTUNG 5 STORUNGSBESEITIGUNG e Ubersichtstabelle Die folgende bersicht unterst tzt Sie dabei eventuell auftretende Probleme mit dem MILLI Q 185 PLUS System genauer zu diagnostiziren und zu l sen Wenn Sie sich unsicher sind worin das Problem besteht oder wie das Problem zu l sen ist wenden Sie sich bitte an die Serviceabteilung Ihrer n chstgelegenen Millipore Niederlassung eine Liste der Adressen finden Sie am Ende diese Bedienungsanleitung Problem Grund L sung Keine Stromversorgung zum MILLI Q 185 PLUS System Powerlampe leuchtet nicht EXCHANGE PAK Lampe leuchtet EXCHANGE PAK Lampe leuchtet st ndig Die UV Anzeigelampe leuchtet nicht obwohl das System produziert oder im RECIRCULATION Modus steht Die Anzeige BATTERY leuchtet auf Keine Stromversorgung am Hauptanschluss Netzkabel nicht angeschlossen Hauptsicherung durchgebrannt Platinensicherung durchgebrannt Q Pak mu ausgewechselt werden Q Pak nicht vorhanden oder nicht korrekt eingebaut Die UV Lampensicherung ist durchgebrannt Die UV Lampe ist defekt Temperatur gt 35 C wird angezeigt Die Batterie ist entladen Kontrollieren Sie das Stromkabel Kontrollieren Sie die Verbindungen Ersetzen Sie die Haupt
46. de 185 nm 254 nm qui oxyde les mati res organiques et d truit les bact ries puis travers le Q PAK dont la fonction est de retenir les ions et les mati res organiques oxyd es Une vanne 3 voies permet de recirculer l eau produite en amont de la pompe jusqu l obtention de la qualit d sir e puis d alimenter le point d utilisation travers un filtre 0 22 um e Sch ma de principe La cha ne fonctionnelle de MILLI Q 185 PLUS est repr sent e figure 2 Elle comprend A Une lectrovanne d entr e B Une pompe C Une lampe UV mont e dans un carter D Un pack de purification de l eau Q PAK E Une sonde de mesure de la r sistivit de l eau produite F Une vanne 3 voies G Un filtre final 0 22 um MILLIPAK 40 H Un clapet anti retour INTRODUCTION 1 e Caract ristiques Dimensions Hauteur Largeur Profondeur Poids en fonctionnement Sp cifications 495 mm 19 5 in 297 mm 11 7 in 433 mm 17 in 17 kg Sp cifications lectriques 230 V 50 Hz 180 VA Fusible 1A retard Sp cifications hydrauliques Tuyau d alimentation en eau Pression d eau d entr e D bit d eau d entr e 28mm longueur 3 m maximum 0 03 bar 0 5 psi minimum 1 bar 15 psi maximum 1 5 1 mn Performances D bit d eau produite Cot alimentation en eau osmos e 1 5 mn maximum 5 ppb typique mesur avec appareil ANATEL A 100 P 2 INTRODUCTION 2 INSTALLA
47. de tres v as en PRODUCTION El caudal de agua es muy bajo en modo de operaci n y con la v lvula de tres v as en PRODUCTION La temperatura del agua pretratada es mayor de 40 C El termistor es defectuoso o est mal conectado a la sonda de resistividad El bloque Q PAK est agotado V lvula de corte cerrada impidiendo la entrada de agua al equipo La v lvula solenoide de entrada funciona mal La bomba no est correctamente cebada El aporte de agua al equipo es insuficiente El filtro final Millipak contiene aire El filtro final Millipak est obturado Compruebe la temperatura del agua que entra al equipo e intente reducirla ver m s arriba P ngase en contacto con el Servicio T cnico de Millipore Sustituya el bloque QPAK vea el cap tulo 4 MANTENIMIENTO Abra la v lvula de corte P ngase en contacto con el Servicio T cnico de Millipore Cebe la bomba introduciendo en ella agua a presi n o por gravedad Aseg rese de que siempre hay aporte de agua suficiente caudal y presi n del agua di metro longitud y recorrido del tubo de entrada ver m s abajo Verifique el aporte de agua al equipo caudal gt 1 5 l min presi n columna gt 30 cm del agua di metro gt 8 mm longitud lt 3 m y recorrido sin bucles del tubo de entrada Purgue el aire del filtro Millipak ver el capitulo 3 OPERACION Sustituya el filtro Millipak vea el ca
48. debe adquirir por separado ver cap tulo 7 INFORMACION PARA PEDIDOS G Bloque de purificaci n QPAK H Filtro final Millipak 40 de 0 22 um e Localizaci n del equipo El MILLI Q 185 PLUS puede ser instalado directamente sobre una mesa o banco de trabajo o ser colgado sobre una pared ciertas operaciones de mantenimiento precisan abrir la cubierta trasera para lo cual el equipo debe ser separado de la pared Para el montaje mural es imprescindible verificar que tanto la propia pared como los elementos de fijaci n sean capaces de soportar el peso del equipo en funcionamiento 17 kg necesitar adem s una escuadra para montaje mural no incluida con el equipo ver cap tulo 7 INFORMACI N PARA PEDIDOS Es preciso realizar una preinstalaci n unatoma de corriente permanente que no se interrumpa por la noche ni los fines de semana y una toma de agua pretratada con llave de corte y rosca macho de 1 2 pr ximas al equipo y eventualmente un regulador de presi n ninguno de estos componentes se incluye con el equipo El MILLI Q 185 PLUS puede utilizarse conectado a un dep sito autom tico Millipore que le suministrar el agua pretratada En la figura 4 se ilustran las diversas conexiones a realizar En caso necesario consulte a Millipore e Instalaci n CONEXI N DE ENTRADA DEL AGUA FIGURA 5 Para agua pretratada tomada de un dep sito 1 Cierre la llave de corte instalada en la toma de agua pretratada e
49. e della lampada U V Se non possibile ridurre la temperatura dell acqua di alimentazione allora rimuovere il cavallotto E sulla scheda PC per disabilitare questa funzione Contattare l Assistenza Tecnica Controllare la temperatura dell acqua di alimentazione e diminuirla se troppo elevata Chiamare l Assistenza Tecnica Sostituire il Q PAK Vedere capitolo MANUTENZIONE 12 RICERCA E RIPARAZIONE GUASTI PROBLEMA CAUSA AZIONI CORRETTIVE Assenza di produzione d acqua in modo OPERATE Bassa portata d acqua in modo OPERATE La valvola dell acqua di alimentazione chiusa Non funziona l elettro valvola d ingresso La pompa sta funzionando a secco Mancanza di acqua di alimentazione Presenza di aria nel filtro finale MILLIPAK 40 il filtro MILLIPAK intasato Aprire la valvola di alimentazione Chiamare l Assistenza Tecnica La pompa opera solo con acqua di alimentazione in leggera pressione Alimentare il sistema per gravit o in pressione Verificare la linea di alimentazione idrica Verificare la pressione il diametro dei tubi la lunghezza dei tubi e la portata Eliminare l aria dal filtro finale MILLIPAK 40 vedere il capitolo OPERATION sezione AVVIAMENTO Sostituire il filtro finale MILLIPAK 40 Vedere il capitolo MANUTENZIONE RICERCA E RIPARAZIONE GUASTI 13 14 RICERCA E RIPARAZIONE GUASTI 6 APPENDICE e Appendice 1 Sostituzione del
50. e en temp rature de la lampe Allum lorsque la lampe U V est allum e et que son efficacit est optimum e Utilisation du clavier Le clavier permet de contr ler le mode de fonctionnement de l appareil et d afficher certains param tres DESIGNATION FONCTION OPERATE STANDBY En appuyant sur cette touche on fait appara tre successivement les modes STANDBY et Production TEMPERATURE En mode STANDBY en appuyant sur cette touche la temp rature de r f rence 25 C est affich e Lorsque la touche est relach e l affichage de la temp rature disparait apr s 3 secondes En mode RECIRCULATION ou production en appuyant sur cette touche la temp rature de l eau est affich e Lorsque la touche est relach e l affichage de la temp rature disparait apr s 3 secondes 6 UTILISATION e Connexion lectrique l arriere Entr e REMOTE STANDBY Cette entr e permet le contr le distance du fonctionnement du MILLI Q 185 PLUS Modes REMOTE STANDBY Production contacter le service technique Millipore pour informations e Mise en service Figure 7 1 S assurer que le Q PAK est bien en place et que les raccordements sont bien effectu s Ouvrir la vanne d alimentation en eau Placer la vanne 3 voies RECIRCULATION PRODUCTION A sur la position PRODUCTION Placer un r cipient B sous le raccord C de fixation du filtre 0 22 um Mettre l appareil sous tension en app
51. e system by gravity feed or by pressure Verify the feedwater line to the system Verify correct pressure tubing diameter tubing length and flow Purge air from MILLIPAK 40 final filter see OPERATION chapter START UP section Replace MILLIPAK 40 final filter See MAINTENANCE chapter TROUBLESHOOTING 13 14 TROUBLESHOOTING 6 APPENDIX e Appendix 1 Main fuse replacement Figure 10 e Appendix 3 Replacement of fuse on U V Lamp P C board Figure 11 1 Switch OFF power to the MILLI Q 185 PLUS 2 Unplug and disconnect the main power cord to the system 3 Remove the fuse holder A figure 1 O 4 Remove the faulty fuse B and replace by new fuse C 1 Follow the same procedure as Appendix 2 change fuse D of the U V lamp P C Board B NOTE When changing a faulty fuse we suggest a new fuse be kept as a spare in the secondary position 5 Replace the fuse holder in position e Appendix 2 Main P C Board fuse replacement Figure 11 1 Switch OFF power to the MILLI Q 185 PLUS system and unplug the power cable 2 Unscrew the knurled knob figure 1 L to remove rear cabinet 3 Change the fuse C of the Main P C Board A APPENDIX 15 16 APPENDIX 7 ORDERING INFORMATION Description Catalogue number SYSTEM MILLI Q 185 PLUS 220 V 50Hz ZFMQ 050 UV Water purification system U V lamp already installed QPAK NOT INCLUDED EXPENDABLES QPAK 1 kit Feed water
52. ear cabinet plug in the power cable and switch the system ON Verify the correct functioning of the U V lamp U V indicator light should be illuminated during OPERATE mode 10 MAINTENANCE 5 TROUBLESHOOTING e Troubleshooting table If the MILLI Q 185 PLUS unit is not functioning correctly please look initially at the table below This table is an initial aid in helping you to diagnose the reason for the incorrect functioning of the system If this is not sufficient please contact your local Millipore Service Department List of addresses at the back of this manual PROBLEM CAUSE REMEDIAL ACTION No power to MILLI Q 185 PLUS The power light is OFF EXCHANGE PACK light constantly illuminated The U V indicator light does not light up when the system is in production or RECIRCULATION mode BATTERY is displayed on the screen EXCHANGE PACK light flashing Main socket is not receiving power Power cord not properly connected Main power fuse blown P C board fuse blown Q PAK needs to be changed Q PAK is not in place or has been incorrectly installed The U V lamp fuse is blown The U V lamp is defective TEMPERATURE gt 35 C is displayed Battery discharged Check mains Check connections Replace main fuse appendix 1 Replace P C board fuse appendix 2 Replace Q PAK See MAINTENANCE chapter Replace Q PAK See MAINTENANCE chapter R
53. en Rufen Sie den Millipore Service an falls der Wert nicht angezeigt wird Falls die Temperatur korrekt kalibriert wurde sollte durch Dr cken der Taste OPERATE STANDBY die Anzeige Test 15 0 MQ cm 1 MQ cm angezeigt werden Rufen Sie die Millipore Serviceabteilung an falls der spezifizierte Wert nicht erscheint Stellen Sie das System in den STANDBY Modus wenn es nicht gebraucht wird Entnehmen Sie Wasser vom System um die Temperatur zu senken und um ein Wiedereinschalten der UV Lampe zu erreichen Sollte es nicht m glich sein die Speisewassertemperatur zu reduzieren entfernen Sie die Uberbriickung E auf der Hauptplatine um diese Funktion au er Betrieb zu setzen Rufen Sie die Millipore Serviceabteilung an Pr fen Sie die Speisewassertemperatur und senken Sie diese ggfs Rufen Sie die Millipore Serviceabteilung an 12 ST RUNGSBESEITIGUNG Problem Grund L sung Der Widerstand des Wassers im System erreicht nicht 18 2 MQ cm nach einigen Minuten der Rezirkulation Es wird kein Wasser im OPERATE Modus produziert Niedrige Flie rate im OPERATE Modus Das Q Pak ist ersch pft Absperrventil zum Speisewasser ist geschlossen Einla ventil arbeitet nicht korrekt Die Pumpe l uft trocken Unzureichende Speisewasserzufuhr Der Millipak 40 Endfilter ist durch Luft verblockt Der Millipak 40 Endfilter hat sich zugesetzt Ersetzen Sie das Q Pak siehe Absc
54. en E Wenn notwendig r cken Sie das Q Pak leicht hin und her 5 F hren Sie den Sicherungshebel wieder in seine Position nach rechts und lassen ihn einrasten F 4 INSTALLATION 3 BETRIEB e Standardbetriebsfunktionen Das MILLI Q 185 PLUS System fuhrt bestimmte Betriebsfunktionen durch Einige k nnen ber die Tastatur aktiviert werden andere sind vorprogrammiert und laufen automatisch ab BETRIEBSZUSTANDS AKTIVIERUNG STATUS DES MILLI Q 185 PLUS ANZEIGE SYSTEMS STANDBY Dr cken Sie auf OPERATE STANDBY Das System ist im STANDBY Modus und produziert kein wenn das Ger t im OPERATE Modus ist aufgereinigtes Wasser TEMPERATURE 25 C Dr cken Sie auf TEMPERATURE wenn Anzeigen der Referenztemperatur 25 C das Ger t im STANDBY Modus ist Kalibrierungstemperatur TEST MQ cm Dr cken Sie auf OPERATE STANDBY Anzeige der Ergebnisse des automatischen Selbsttests zur wenn das System im STANDBY Verifizierung der Systemkalibrierung 15 1 MQ cm wird f r Modus ist 4 Sekunden angezeigt PRODUCT MQ cm Die Anzeige erscheint automatisch fir Anzeige des Widertandes des Produktwassers A Sekunden nachdem OPERATE STANDBY gedriickt wurde wenn das System im STANDBY Modus war Diese Anzeige erscheint nach der Anzeige des Autotests TEMPERATURE C Driicken Sie auf TEMPERATURE wenn Anzeige der Produktwassertemperatur am Q Pak Ausla das System im OPERATE oder RECIRCULATION Modus ist RECIRCULATION Automatische
55. ening in order to allow the Q PAK to rehydrate in the system overnight e Replacement of final filter MILLIPAK 40 Figure 8 1 Put the MILLI Q 185 PLUS on STANDBY mode 2 Press on the twin tabs H of the point of use cover G to remove the cover and the MILLIPAK 3 Pull on the cover to remove it from MILLIPAK 4 Unscrew used MILLIPAK from its fitting 5 Install new MILLIPAK as described in INSTALLATION chapter e Replacement of the U V lamp Figure 9 The rear cabinet of the unit should be removed When the MILLI Q 185 PLUS is wall mounted the system should be lifted down from its support bracket 1 Switch OFF the system and remove the power cable figure 1 N P MAINTENANCE 9 2 Unscrew the knurled knob figure 1 L and also the pin for the wall mounting bracket figure 1 K if wall mounted 3 Remove the rear cover by sliding it backwards 4 Disconnect connector A from the U V lamp unit by pulling up 5 Unscrew locking ring B withdraw the quartz tube D the used U V lamp and the O ring E as shown 6 Put in place the new quartz tube containing the new U V lamp USE GLOVES WHEN HANDLING THESE NEW ELEMENTS The tube should rest on a spring which will automatically centre it in the correct position 7 Replace the O ring E place the pressure ring C in position and screw down the locking ring B to tighten the whole assembly 8 Connect the U V lamp connector A 9 Replace the r
56. eplace the fuse on the P C board for the U V lamp see appendix 3 Replace the U V lamp see MAINTENANCE chapter Internal water temperature is too high See section TEMPERATURE gt 35 C indication later in this table Leave the system under power for 48 hours to recharge the battery switch off the system for 2 seconds to erase the display BATTERY at the end of the recharge TROUBLESHOOTING 11 PROBLEM CAUSE REMEDIAL ACTION TEST INCORRECT is displayed after the autotest PRODUCT XX MQ cm displayed TEMPERATURE gt 35 C is displayed during PRODUCTION or RECIRCULATION mode TEMPERATURE lt 0 C or TEMPERATURE gt C is displayed during OPERATE mode Poor calibration of temperature circuit Poor calibration of resistivity circuit Presence of air in the measurement circuit Fault in calibration of measurement circuit TEST INCORRECT The water temperature in the system has reached 36 C and needs to come down to 35 C to relight the U V lamp This is caused by leaving the system on OPERATE mode for too long without drawing water Feed water temperature is too high Feedwater temperature is gt 40 C The thermistor or its connection to the resistivity cell is defective With system in STANDBY mode press button TEMPERATURE TEMPERATURE 25 C should be displayed Call MILLIPORE Technical Service if the value is different If the temper
57. fusibile Appendice 2 Sostituzione fusibile Scheda PC principale Figura 10 principale Figura 11 1 Spegnere il sistema 1 Spegnere il sistema e rimuovere il cavo di alimentazione dalla presa di corrente 2 Rimuovere il cavo di alimentazione dalla presa di corrente 2 Svitare la manopola L figura 1 e rimuovere la parte posteriore 3 Rimuovere il porta fusibile A posizione O in figura 1 3 Sostituire il fusibile C della Scheda PC principale A 4 Togliere il fusibile bruciato B e sostituirlo con uno nuovo C NOTA Cambiando il fusibile suggeriamo di porre un secondo fusibile nell alloggiamento a lato come riserva e Appendice 3 Sostituzione del fusibile sulla 5 Reinserire il portafusibile in sede scheda PC della lampada U V Figura 11 Seguire le stesse procedura di Appendice 2 sostituire il fusibile D sulla scheda PC B della lampada U V APPENDICE 15 16 APPENDICE 7 INFORMAZIONI PER L ORDINE Descrizione Numero di Catalogo SISTEMA MILLI Q 185 PLUS 220V 50 Hz ZFMQOSOUV Sistema di purificazione Lampada U V installata QPAK NON INCLUSO MATERIALE Kit QPAK 1 Alimentazione Osmosi CPMQKOSR1 DI CONSUMO Inversa Distillazione include 1 QPAK 1 e 1 filtro MILLIPAK 40 QPAK 1 CPMGQOOARI Kit QPAK 2 Alimentazione Deionizzazione include 1 QPAK 2 e 1 filtro MILLIPAK 40 CPMQKO5D2 QPAK 2 CPMQOOAD2 Filtro MILLIPAK 40 0 22 um Conf da 2 MPGLOASK2 Kit sostituzione lampad
58. genieros Militares 85 PB M xico 11230 D F Tel 525 576 96 88 FAX 525 576 87 06 THE NETHERLANDS Millipore B V Penningweg 33 Postbus 166 NL 4870 AD Etten Leur N B Tel 01608 22000 Telex 54 840 milwa nl FAX 01608 22436 NORWAY Millipore AS Postboks 39 Simensbr ten N 1107 Oslo Tel 22 67 82 53 FAX 22 68 53 15 POLAND Millipore Austria Ges m b H Oddzial w Warszawie Ul Pulawska 107 d 21 PL 02 595 Warszawa Tel 48 22 44 76 10 48 22 44 09 02 Telex 825 422 FAX 48 22 44 09 02 PUERTO RICO Millipore Corporation Puerto Rico Branch P O Box 11977 Cidra Puerto Rico 00639 Tel 809 747 8444 FAX 809 747 8449 SINGAPORE Millipore Asia Ltd 307 01 Jumbo Industrial Bldg 19 Kim Keat Road Singapore 1232 Tel 65 253 2733 Telex RS 56556 MILLIP FAX 65 254 4056 SPAIN Millipore Ib rica S A Avda del Llano Castellano 13 32 E 28034 Madrid Tel 91 729 03 00 Telex 23545 milli e FAX 91 729 29 09 Millipore Ib rica S A Entenza 24 E 08015 Barcelona Tel 93 325 96 16 Telex 50524 wtrs e FAX 93 325 98 96 Millipore Ib rica S A Edificio Congreso m dulo 320 Pol gono del Aeropuerto E 41020 Sevilla Tel 95 425 68 77 FAX 95 425 62 06 SWEDEN Millipore AB Box 7090 S 172 07 Sundbyberg Tel 08 628 69 60 FAX 08 628 64 57 SWITZERLAND Millipore AG Chriesbaumstrasse 6 CH 8604 Volketswil Tel 01 945 3242 Telex 82 94 08 MILAG CH FAX 01 945 3766 T
59. hnitt WARTUNG ffnen Sie das Absperrventil Rufen Sie die MILLIPORE Servicabteilung an Die Pumpe kann nur Wasser ziehen wenn sie vollst ndig gef llt ist F llen Sie das System mit Wasser durch Schwereflu oder Druck Kontrollieren Sie die Speisewasserzuleitung Stellen Sie den korrekten Druck den Schlauchdurchmesser Schlauchl nge und die Flie rate sicher Entfernen Sie die Luft aus dem Millipak 40 Endfilter siehe Kapitel BETRIEB Absatz Inbetriebnahme Ersetzen Sie den Millipak 40 Endfilter siehe Kapitel WARTUNG ST RUNGSBESEITIGUNG 13 14 STORUNGSBESEITIGUNG 6 ANHANG Anhang 1 Auswechseln der Hauptsicherung e Anhang 3 Auswechseln der Sicherung f r die Abbildung 10 UV Lampe Abbildung 11 1 Stellen Sie den Hauptschalter des Milli Q Plus 185 Systems auf OFF Wechseln Sie die Sicherung D f r die UV Lampe auf der Haupt platine B entsprechend der Anleitung in Anhang 2 2 Unterbrechen Sie die Stromversorgung zum System durch Abziehen des Stromversorgungskabel 3 Entfernen Sie den Sicherungshalter A Position O in Abbildung 1 4 Entfernen Sie die defekte Sicherung B und ersetzen sie durch eine neue Sicherung C Hinweis Wenn Sie eine defekte Sicherung austauschen schlagen wir vor da Sie eine neve Sicherung stets als Ersatzteil in der 2 Position bereithalten 5 Baven Sie den Sicherungshalter wieder ein e Anhang 2 Sicherungswechsel auf der Hauptplatine Abbildu
60. hould not be relied upon TECHNICAL INFORMATION In the event of a breach of the foregoing warranty Millipore s sole obligation shall be to repair or replace at its option any product or part thereof that proves defective in materials or workmanship within the warranty period provided the customer notifies Millipore promptly of any such defect The exclusive remedy provided herein shall not be deemed to have failed of its essential purpose so long as Millipore is willing to repair or replace any nonconforming Millipore product or part Millipore shall not be liable for consequential damages resulting from economic loss or property damages sustained by a customer from the use of its products However in some states the purchaser may have rights under state law in addition to those provided by this warranty
61. ht werden kann entwickelt Diese Wasserqualit t kann erreicht werden indem man zur Speisung des Systems Laborwasser das durch Umkehrosmose oder Destillation vorgereinigt wurde verwendet Das MILLI Q 185 PLUS System produziert bei Bedarf bis zu 1 5 l min ultrareines Wasser Diese Wasserqualit t sollte fur alle kritischen Anwendungen bei denen ein m glichst niedriger Gehalt an Organika verlangt wird eingesetzt werden z B kritische HPLC GC MS Langmuir Blodgett Monolayers usw Die Hauptkomponenten aus denen das MILLI Q 185 PLUS System aufgebaut ist sind wie folgt in Abbildung 1 dargestellt A Wasseraufbereitungsmodul Q Pak 1 B Gesch tzte Entnahmestelle C Endfilter an der Entnahmenstelle Millipak 40 Filtereinheit mit 0 22 um Membran D 3 Wege Ventil an der Entnahmestelle E Tastatur mit Anzeige F Q Pak Sicherungshebel G Kontrolleuchten H LCD Anzeige I Tastatur J Anschlu des Speisewassers K Abnehmbarer Stopfen Vorrichtung f r Wandmontage L R ndelschraube zur Sicherung des r ckw rtigen Teils des Systems M AnschluBbuchse f r Fernbedienung N Netzsteckeranschlu O Halter f r die Hauptsicherung P Ein Ausschalter Q W rmeableitung e Beschreibung der Funktionen Das vorgereinigte Speisewasser Umkehrosmosewasser oder Destillat wird durch eine eingebaute Pumpe durch eine Kammer gef rdert in der das Speisewasser ultraviolettem Licht UV mit niedrigen Wellenl ngen 18
62. iden Seiten der Abdeckung befinden ein und lassen Sie die beiden Laschen in den Vertiefungen J die f r diesen Zweck vorgesehen sind einrasten Das MILLI Q 185 PLUS System ist nun f r den Einsatz vorbereitet 8 BETRIEB e Wasserentnahme 1 Dr cken Sie die Taste OPERATE STANDBY Abbildung 1 um das System in den OPERATE Modus zu bringen 2 Nach 6 Sekunden leuchtet die Anzeigeleuchte UV Abbildung 1 G auf Warten Sie mit der Wasserentnahme weitere 30 Sekunden bis die Anzeige kontinuierlich leuchtet und der Widerstand einen Wert von 18 2 MQ cm erreicht hat Diese Verz gerung gestattet der Lampe ihre optimale Temperatur zu erreichen 3 Die Wasserentnahme erfolgt nun durch Drehen des 3 Wege Ventils Abbildung 1 D auf die Position PRODUCTION 4 Nach der Wasserentnahme wird das 3 Wege Ventil zur ck auf die Position RECIRCULATION gestellt Dr cken Sie die OPERATE STANDBY Taste um das System in den STANDBY Modus zu bringen Hinweis Wenn Sie kein Wasser ben tigen lassen Sie das MILLI Q 185 PLUS System im STANDBY Modus Um die hohe Wasserqualit t konstant aufrecht zu erhalten rezirkuliert das System automatisch w hrend der Phasen des Nichteinsatzes das Wasser in jeder Stunde f r 15 Minuten wenn das System im STANDBY Modus steht Die Anzeige zeigt w hrend dieser Zeiten RECIRCULATION Stellen Sie sicher da das 3 Wege Ventil w hrend des STANDBY Modus in der Position RECIRCULATION steht um zu verhindern da w
63. io ordinare la staffa di montaggio N Cat ZFMQOOWMB e verificare che la parete sia in grado di sopportare il peso operativo dell unit 17 Kg La figura 4 mostra la connessione del MILLI Q 185 PLUS con differenti opzioni di alimentazione serbatoio o linea in pressione NOTA La valvola di intercettazione sulla linea pressurizzata il regolatore di pressione ed il manometro mostrati in figura 4 non sono forniti col sistema e Installazione CONNESSIONE CON L ACQUA DI ALIMENTAZIONE FIGURA 5 Acqua di alimentazione contenuta in un serbatoio 1 Tagliare il tubo di alimentazione C nella lunghezza necessaria 3 m 2 Rimuovere il tappo di protezione B dalla connessione INLET D premendo il collare A ed estraendo il tappo 3 Connettere il tubo C alla connessione INLET inserendo il tubo all interno del connettore Verificare la tenuta tirando pi volte il tubo 4 Connettere il tubo alla valvola di uscita del serbatoio Questa valvola deve essere dotata di attacco per tubo da 8 mm di diametro Acqua di alimentazione da una rete di distribuzione in pressione 1 Se la pressione maggiore di un bar necessario installare un riduttore di pressione N Cat ZFMQOOOPR 2 Connettore il tubo di alimentazione C all uscita del regolatore di pressione INSTALLAZIONE 3 e Installazione del blocco di purificazione Q PAK Figura 6 1 Ruotare verso sinistra la leva di bloccaggio facendo pressione sulla
64. ip e d un adaptateur pour tube de y 8 mm A partir d une boucle de distribution de l eau sous pression 1 La pression doit tre r duite utiliser pour cela un r ducteur r gula teur de pression Cat N ZFMQ 000 PR 2 Conneder le tuyau d alimentation C la sortie du r gulateur de pression INSTALLATION 3 e Mise en place du pack de purification Q PAK Figure 6 1 Amener la poign e de verrouillage du pack vers le bas en appuyant dessus et retirer les bouchons de protection A 2 Retirer les bouchons de protection B du Q PAK 3 Mouiller les 2 joints C du pack l aide de quelques gouttes d eau 4 Positionner le Q PAK dans son logement Maintenir fermement le MILLI Q 185 PLUS D et emboiter le pack E en cr ant de l gers mouvement de pivotement 5 Verrouiller la poign e de maintien du pack F 4 INSTALLATION 3 UTILISATION e Modes de fonctionnement Le MILLI Q 185 PLUS pr sente plusieurs modes de fonctionnement control s par le clavier ou par le programme interne de l appareil Les modes de fonctionnement sont r pertori s ci dessous MODES DE FONCTIONNEMENT ACTION ETAT DU MILLI Q 185 PLUS STANDBY TEMPERATURE 25 C TEST MQ cm PRODUCT MQ cm TEMPERATURE C RECIRCULATION Appui sur le bouton OPERATE STANDBY Appui sur le bouton TEMPERATURE en mode STANDBY Appui sur le bouton OPERATE STANDBY 4 secondes apr s l appui sur le bo
65. izzato TEMPERATURE lt 0 C o TEMPERATURE gt C durante il modo OPERATE La resistivit dell acqua non raggiunge i 18 2 MQ x cm dopo parecchi minuti di ricircolo Circuito della temperatura mal calibrato Circuito della resistivit mal calibrato Presenza di aria nel circuito di misura Difetto di calibrazione del circuito di misura TEST INCORRECT La temperatura dell acqua nel sistema ha superato i 36 C ed necessario che scenda sotto i 35 C perch possa riaccendersi la lampada U V Ci succede quando si lascia il sistema in modo OPERATE per lungo tempo senza prelevare acqua La temperatura dell acqua gt di 40 C Il termistore o la sua connessione alla cella di misura della resistivit difettosa I Q PAK esausto Con il sistema in modo STANDBY premere il pulsante TEMPERATURE Si dovrebbe visualizzare TEMPERATURE 25 C Chiamare l Assistenza Tecnica se il valore differente Se la temperatura di calibrazione corretta premere il pulsante OPERATE STANDBY si dovrebbe visualizzare TEST 15 0 MQ x cm 1 MQ x cm Chiamare l Assistenza Tecnica se il valore fuori specifica sfiatare l aria dal Q PAK e dal circuito di misura aprendo la valvola del punto di prelievo Calibrare il circuito di misura vedi sopra Porre il sistema in modo STANDBY quando non in uso Scaricare acqua per favorire la diminuzione della temperatura e permettere la riaccension
66. llumina quando il sistema in modo PRODUCTION o RECIRCULATION Viene visualizzato BATTERY Assenza di alimentazione alla presa principale Cavo di alimentazione non perfettamente collegato Fusibile principale bruciato Fusibile sulla scheda PC bruciato Necessit di sostituzione del Q PAK Q PAK non installato o non correttamente installato Fusibile della lampada U V bruciato La lampada U V difettosa viene visualizzato TEMPERATURE gt 35 C Batteria scarica Controllare l alimentazione Controllare l allacciamento Sostituire il fusibile principale appendice 1 Sostituire il fusibile della scheda PC appendice 2 Sostituire il Q PAK Vedere capitolo MANUTENZIONE Sostituire il Q PAK Vedere capitolo MANUTENZIONE Sostituire il fusibile sulla scheda della lampada U V appendice 3 Sostituire la lampada U V Vedere capitolo MANUTENZIONE Temperatura interna dell acqua troppo elevata Vedere TEMPERATURE gt 35 C Lasciare il sistema sotto tensione per 48 ore per ricaricare la batteria quindi spegnere il sistema per 2 secondi per eliminare la visualizzazione BATTERY RICERCA E RIPARAZIONE GUASTI 11 PROBLEMA CAUSA AZIONI CORRETTIVE Viene visualizzato TEST INCORRECT dopo l Auto test a 15 MQ x cm Viene visualizzato PRODUCT XX MQ cm Viene visualizzato TEMPERATURE gt 35 C durante i modi PRODUCTION o RECIRCULATION Viene visual
67. locco di purifica zione Q PAK ed il filtro finale MILLIPAK 40 Sostituire la lampada U V Sostituire il filtro finale MILLIPAK 40 Se il filtro stato montato da poco controllare la qualit dell acqua di alimentazione al MILLI Q 185 PLUS e Sostituzione del blocco di purificazione Q PAK 1 Porre il sistema MILLI Q 185 PLUS in modo STANDBY NON SPEGNERE IL SISTEMA 2 Sbloccare il braccio di ritenuta del Q PAK vedi figura 1 F 3 Togliere il Q PAK esausto 4 Installare il nuovo Q PAK come descritto nel capitolo INSTALLAZIONE NOTA E preferibile effettuare la sostituzione nel tardo pomeriggio in modo da permettere al nuovo Q PAK di reidratarsi perfettamente durante la notte e Sostituzione del filtro finale MILLIPAK 40 Figura 8 1 Porre il MILLI Q 185 PLUS in modo STANDBY 2 Premere le due linguette H poste sul coperchio G per rimuovere il coperchio e il MILLIPAK 40 A Svitare il MILLIPAK 40 dalla connessione 5 Installare il nuovo MILLIPAK 40 come descritto nel capitolo INSTALLAZIONE MANUTENZIONE 9 e Sostituzione della lampada U V Figura 9 E necessario rimuovere la parte posteriore dello strumento Se il MILLI Q 185 PLUS montato a muro necessario toglierlo dalla staffa di supporto La Spegnere il sistema e rimuovere il cavo di alimentazione figura 1 N P Svitare il volantino figura 1 L e anche l inserto per la staffa di montaggio a muro figura
68. mettre la vanne 3 voies sur la position RECIRCULATION Appuyer sur le bouton OPERATE STANDBY pour mettre l appareil en mode STANDBY UTILISATION NOTA Lorsque vous ne puisez pas d eau laisser le MILLI Q 185 PLUS en mode STANDBY Afin de maintenir la qualit de l eau entre chaque utilisation l appareil recircule l eau automatiquement 15 mn toutes les heures affichage RECIRCULATION En mode STANDBY positionner la vanne 3 voies sur RECIRCULATION pour viter tout coulement de l eau pendant le mode RECIRCULATION 4 ENTRETIEN e Tableau de p riodicit s PERIODICIT ACTION Lorsque la lampe EXCHANGE PACK clignote ou lorsque la r sistivit n atteint plus 18 2 MQ cm apr s quelques minutes de RECIRCULATION Changer le pack de purification Tous les ans ou lorsque le voyant Changer la lampe U V U V ne s allume plus Lorsque le d bit de soutirage travers le filtre final devient faible Si celui ci est en place depuis peu de temps v rifier la qualit de l eau d alimentation du MILLI Q 185 PLUS Q PAK etle filtre final MILLIPAK 40 Changer le filtre final MILLIPAK 40 e Remplacement du pack de purification 1 Mettre le MILLI Q 185 PLUS en mode STANDBY ne pas couper le secteur 2 D verrouiller la poign e de maintien voir figure 1 F 3 Retirer le Q PAK usag en le tirant 4 Installer le Q PAK neuf comme d crit dans le chapitre INSTALLA TION NOTA Il est pr
69. mostrando el resultado del auto test que verifica la precisi n del calibrado del resistivimetro la lectura debe ser de 15 1 MQ cm durante 4 segundos En modo de operaci n mostrando la resistividad del agua producida durante el funcionamiento de la bomba Seg n la posici n de la v lvula de tres v as durante el modo de operaci n el equipo puede estar en recirculaci n v lvula en RECIRCULATION o en producci n v lvula en PRODUCTION En modo de operaci n mostrando la temperatura del agua purificada a la salida del bloque Q PAK En modo de espera recirculando autom ticamente el agua conte nida en el equipo Esta funci n se activa durante 15 minutos cada hora a fin de mantener la calidad del agua durante los periodos de inactividad del equipo La recirculaci n comienza autom tica mente cuando han transcurrido 45 minutos desde que el equipo ha sido puesto en modo de espera y se repite una vez cada hora durante todo el tiempo que el equipo se mantenga en modo de espera Al poner el equipo en id de operaci n el mensaje RECIRCULATION aparece en pantalla durante unos segundos OPERACION 5 e Otra informaci n disponible MENSAJE EN PANTALLA INTERPRETACION PRODUCT XX X MQ cm TEST INCORRECT BATTERY EXCHANGE PACK piloto luminoso UV piloto luminoso Este mensaje indica que el valor de resistividad est fuera de escala Ver DIAGNOSTICO Y SOLUCION DE PROBLEMAS Este mens
70. na luce fissa Scaricare 2 3 litri di acqua Porre quindi nuovamente il sistema in modo STANDBY premendo una volta il pulsante OPERATE STANDBY e Installazione del filtro finale millipak 40 0 22 um Figura 8 Dopo che il Q PAK stato spurgato dall aria e lasciato reidratare per una notte si procede all installazione del filtro finale MILLIPAK 1 Avvolgere sul filetto A del MILLIPAK 2 o 3 giri di nastro di Teflon in modo da garantire la tenuta 2 Avvitare il MILLIPAK sulla connessione femmina C del punto d uscita del sistema MILLI Q 185 PLUS Fare in modo che l uscita di ventilazione D sia accessibile FUNZIONAMENTO 7 3 Premere il pulsante OPERATE STANDBY in modo OPERATE Ruotare la valvola a 3 vie in posizione PRODUCTION A Espellere l aria contenuta nel MILLIPAK 40 allentando il tappo di ventilazione E 5 Quando inizia ad uscire l acqua e non ci sono pi bolle d aria riavvitare il tappo 6 Commutare la valvola a 3 vie in posizione RECIRCULATION e porre il sistema in modo STANDBY 7 Inserire il MILLIPAK nella clip F del coperchio G 8 Installare il MILLIPAK con il suo coperchio sul MILLI Q 185 PLUS facendo una leggera pressione sulle linguette H poste su ciascuna parte del coperchio ed inserirle nelle due fenditure J Il MILLI Q 185 PLUS ora pronto per l uso e Prelievo dell acqua 1 Premere il pulsante OPERATE STANDBY I in figura 1 per porre il sistema in modo OPERATE
71. nal Millipak 40 Obtenci n de agua de alta pureza Cap tulo 4 Mantenimiento Calendario de mantenimiento Sustituci n del bloque de purificaci n QPAK Sustituci n del filtro final Millipak Sustituci n de la l mpara U V I WWW CO CO N m 0 0 50 0 NX NN Os O O Un Cap tulo 5 Diagn stico y soluci n de problemas Gu a de diagn stico y soluci n de problemas Cap tulo 6 Ap ndices Ap ndice 1 sustituci n del fusible general Ap ndice 2 sustituci n del fusible en la tarjeta principal Ap ndice 3 sustituci n del fusible en la tarjeta de la l mpara U V Cap tulo 7 Informaci n para pedidos Anexos sin n mero de p gina Cap tulo 8 Figuras Cap tulo 9 Informaci n complementaria Asistencia t cnica Millipore Garant a 15 15 15 17 1 INTRODUCCION e Descripci n general El sistema MILLI Q 185 PLUS produce a partir de agua pretratada mediante smosis inversa o destilaci n agua ultrapura con el menor contenido en carbono org nico total C O T que permite la tecnolog a actual Un MILLI Q 185 PLUS produce bajo demanda 1 51 min de agua ultrapura Las aplicaciones m s t picas del agua producida por un MILLI Q 185 PLUS son los an lisis instrumentales de alta sensibilidad comolos realizados mediante GC GC MS HPLC monocapas de Langmuir Blodgett e IC Los principales componentes de un MILLI Q 185 PLUS son figura 1 A Bloque de purificaci n QPAK B Pun
72. ng 11 1 Schalten Sie das Milli Q Plus 185 System auf OFF und ziehen Sie das Stromversorgungskabel ab 2 Schrauben Sie die R ndelschraube L Abbildung 1 ab um den R ckteil der Anlage abzunehmen 3 Wechseln Sie die Sicherung C auf der Hauptplatine A ANHANG 15 16 ANHANG FA ORAATLONEN Beschreibung Katalognummer System MILLI Q 185 PLUS 220V 50Hz Wasseraufbereitungssystem ZFMQ 050 UV UV Lampe bereits installiert Q Pak nicht enthalten Verbrauchsmaterial Q Pak 1 Kit Speisewasser Umkehrosmose Destillat CPMQ K05 R1 enth lt 1 x Q Pak 1 und 1 x Millipak Filter Q Pak 1 CPMQ 004 R1 Q Pak 2 Kit CMPQ K05 D2 Speisewasser Deionisat enth lt 1 x Q Pak 2 und 1 x Millipak Filter Q Pak 2 CMPQ 004 D2 Millipakfilter 0 22 um MPGL 045 K2 2 St Pack UV Lampe Austauschkit CFMQ 185 01 Zubeh r Druckminderer ZFMQ 000 PR Wandhalterung ZFMQ 00W MB BESTELLINFORMATIONEN 17 18 BESTELLINFORMATIONEN ESPA OL e Indice Indice Capitulo 1 Introducci n Descripci n general Funci n del equipo Diagrama ds los Especificaciones Cap tulo 2 Instalaci n Desembalado Localizaci n del equipo Instalaci n Conexi n de entrada de agua Instalaci n del bloque de purificaci n QPAK Cap tulo 3 Operaci n Modos normales de operaci n Otra informaci n disponible Uso del teclado Conexiones el ctricas parte trasera Puesta en marcha Instalaci n y purga del filtro fi
73. ngase en contacto con el Servicio T cnico de Millipore Si el calibrado de temperatura ha sido correcto presione la tecla OPERATE STANDBY Si aparece TEST 15 MQ cm 1 MQ cm el calibrado es correcto Si aparece un valor mayor de 16 o menor de 14 p ngase en contacto con el Servicio T cnico de Millipore Purge el aire del Q PAK y del resto del circuito abriend de la v lvula de tres vi s El circuito de medicion debe ser calibrad ver m s arriba Mantenga siempre el equipo en modo de espera pantalla indicando STANDBY mientras no lo utilice Extraiga agua del equipo para que baje la temperatura Si a n as no desaparece el mensaje ni se enciende la l mpara U V compruebe la temperatura del agua que entra al equipo especialmente si el agua procede de un destilador convencional e intente reducirla proba blemente la refrigeraci n del destilador es insuficiente Si no puede reducir la temperatura del agua pretratada es posible aunque no muy recomendable cancelar esta funci n P ngase en contacto con el Servicio T cnico de MILLIPORE 12 DIAGNOSTICO Y SOLUCION DE PROBLEMAS PROBLEMA CAUSA SOLUCION Pantalla indicando TEMPERATURE lt 0 C 6 TEMPERATURE gt C durante el modo de operaci n Pantalla indicando una resistividad del agua purificada inferior a 18 MQ cm tras varios minutos de recirculaci n No sale agua en modo de operaci n y con la v lvula
74. ngbeh lter B unter den Ausla anschlu C f r die Millipak 40 Endfilter Einheit 5 Schalten Sie das System ein indem Sie den Hauptschalter ON OFF auf der R ckseite dr cken Abbildung 1 P Die Anzeige zeigt nun RECIRCULATION an Falls die Anzeige BATTERY erscheint schalten Sie das System f r 2 Sekunden aus und dann wieder ein 6 Falls das System ber eine Ringleitung mit Druckminderer gespeist wird stellen Sie den Ausgangsdruck am Druckminderer zwischen 0 5 und 1 bar ein w hrend das MILLI Q 185 PLUS System auf PRODUCTION steht der 3 Wege Hahn A ist offen in der Position PRODUCTION und Wasser flie t aus dem Anschlu C 2 Lassen Sie das System laufen wobei Wasser an dem Anschlu C austritt Dies gestattet das Entweichen jeglicher Luft aus dem System und dem Q Pak Kontrollieren Sie das F llen des Systems durch mehrmaliges Offnen und Schlie en des 3 Wege Ventils A Nachdem Sie ungef hr 5 7 Liter Wasser aus dem Anschlu C gezapft haben stellen Sie das 3 Wege Ventil A auf die Position RECIRCULATION Dr cken Sie die OPERATE STANDBY Taste zweimal um das System in den STANDBY Modus zu schalten Wenn m glich belassen Sie das System in diesem Modus ber Nacht damit der Inhalt des Q Paks ausreichend quellen kann Dr cken Sie am n chsten Morgen die OPERATE STANDBY Taste Test MQ cm wird f r 4 Sekunden angezeigt 2 Sekunden sp ter leuchtet die Anzeige f r die UV Lampe f r 30 Sekunden auf
75. nutenzione Piano di manutenzione Sostituzione del blocco di purificazione Q PAK Nm _ RWW CO Co NN N Os O O Un 0 Sostituzione del filtro finale MILLIPAK Sostituzione della lampada U V Capitolo 5 Ricerca e riparazione guasti tavola di ricerca e riparazione guasti Capitolo 6 Appendice Appendice 1 Sostituzione del fusibile principale Appendice 2 Sostituzione del fusibile sulla scheda PC principale Appendice 3 Sostituzione del fusibile sulla scheda PC della lampada U V Capitolo 7 Informazioni per l ordine Alla fine del manuale Capitolo 8 Figure Capitolo 9 Informazioni addizionali Assistenza Tecnica Garanzia 1 INTRODUZIONE e Descrizione generale Il sistema MILLI Q 185 PLUS stato sviluppato specificatamente per produrre acqua ultrapura con il pi basso contenuto di sostanze organiche attualmente ottenibile Questo tipo di acqua pu essere ottenuto utilizzando per l alimentazione acqua a grado laboratorio prodotta per Osmosi Inversa o per distillazione il sistema in grado di produrre fino a 1 5 litri minuto di acqua ultrapura nel momento in cui necessaria Questa acqua dovrebbe essere utilizzata per tutte le applicazioni critiche che necessitano del pi basso contenuto di organici possibile es HPLC critici GC MS monostrati di Langmuir Blodgett 1 C componenti principali del MILLI Q 185 PLUS sono mostrati in figura 1 A Modulo di purificazione dell acqua Q PAK 1
76. ot arri re brancher le cordon secteur et mettre l appareil sous tension V rifier le bon fonctionnement de la lampe voyant U V allum en mode de production 10 ENTRETIEN 5 MAINTENANCE e Tableau de maintenance Lors de disfonctionnement du MILLI Q 185 PLUS reportez vous au tableau ci dessous Ce tableau repr sente une premi re aide au diagnostic de panne si celui ci ne s averait pas suffisant contacter le service de maintenance de Millipore liste des adresses en fin de document DEFAUT CAUSES REMEDE Le MILLI Q 185 PLUS est La prise secteur n est pas aliment e V rifier votre installation lectrique hors tension Le cordon secteur est mal connect V rifier les connexions Le fusible secteur est d fectueux Changer le fusible secteur Voir annexe 1 Le fusible du circuit imprim est d fectueux Changer le fusible du circuit imprim Voir annexe 2 Le voyant EXCHANGE PACK Le Q PAK doit tre chang Voir chapitre ENTRETIEN clignote Le voyant EXCHANGE PACK Le Q PAK est mal engag ou enlev Remettre en place le Q PAK Voir chapitre ENTRETIEN est allum Le voyant U V ne s allume pas Le fusible de protection de la lampe U V Changer le fusible du circuit imprim de la lampe U V lorsque l appareil est en est d fectueux Voir annexe 3 production ou en RECIRCULATION La lampe U V est d fectueuse Changer la lampe U V Voir chapitre ENTRETIEN automatique TEMPERATURE gt 35 C est affich L
77. p tulo 4 MANTENIMIENTO DIAGNOSTICO Y SOLUCION DE PROBLEMAS 13 14 DIAGNOSTICO Y SOLUCION DE PROBLEMAS 6 APENDICES e Ap ndice 1 sustituci n del fusible general figura 10 1 Sit e el interruptor principal en OFF 2 Desconecte completamente el cable de entrada de corriente 3 Extraiga el porta fusible A componente O figura 1 4 Extraiga el fusible fundido B y sustit yalo por el de repuesto C NOTA Es conveniente que adquiera otro fusible de repuesto y lo guarde en el alojamiento que hay en el porta fusible 5 Vuelva a colocar el porta fusible Conecte de nuevo el cable y sit e el interruptor general en ON e Ap ndice 2 sustituci n del fusible en la tarjeta 3 principal figura 11 Sit e el interruptor principal en OFF y desconecte completamente el cable de entrada de corriente Desenrosque el tornillo de cierre de la cubierta trasera figura 1 L y el tap n o clavija de fijaci n a la escuadra de montaje mural figura 1 K Extraiga la cubierta posterior tirando de ella hacia atr s Deslice hacia fuera parte de la tarjeta electr nica principal A y sustituya el fusible C Introduzca la tarjeta cierre la cubierta trasera conecte de nuevo el cable y sit e el interruptor general en ON e Ap ndice 3 sustituci n del fusible en la tarjeta de la l mpara U V figura 11 Proceda exactamente igual que en el ap ndice 2 pero sustituya el fusible D
78. que hay en la tarjeta de la l mpara U V B APENDICE 15 16 APENDICE INFORMACI N PARA PEDIDOS Descripci n Referencia SISTEMA Sistema MILLI Q 185 PLUS 220V 50Hz ZFMQ 050 UV MATERIAL FUNGIBLE Kit Q PAKI incluye un bloque de purificaci n Q PAK1 y un filtro CPMQ KO5 R1 final Millipak Bloque de purificaci n Q PAK1 adecuado para alimentaci n con CPMQ 004 R1 agua destilada o de smosis inversa Kit Q PAK2 incluye un bloque de purificaci n Q PAK2 y un filtro CPMQ K05 D2 final Millipak Bloque de purificaci n Q PAK2 adecuado para alimentaci n con CPMQ 004 D2 agua desionizada Filtro final Millipak envase de 2 MPGL 045 K2 Kit de reposici n de l mpara U V CFMQ 185 01 ACCESORIOS Regulador de presi n de entrada ZFMQ 000 PR Escuadra para montaje mural de MILLI Q 185 PLUS JMSP MQW MB INFORMACI N PARA PEDIDOS 17 18 INFORMACI N PARA PEDIDOS ITALIANO e Indice Indice Capitolo 1 Introduzione Descrizione generale Principio di funzionamento Schema Specifiche tecniche Capitolo 2 Installazione Disimballaggio Posizionamento del Milli Q 185 Plus Installazione Connessione all acqua di alimentazione Installazione del blocco di purificazione Q PAK Capitolo 3 Funzionamento Modi operativi standard Visualizzazioni addizionali Uso della tastiera Connessioni elettriche Avviamento Installazione del filtro finale MILLIPAK 40 Prelievo dell acqua Capitolo 4 Ma
79. rato in figura 2 A Elettrovalvola d ingresso B Pompa C Contenitore lampada U V D Blocco di purificazione Q PAK E Sensore di resistivit F Valvola a tre vie G Filtro finale MILLIPAK 40 0 22 um H Valvola di non ritorno INTRODUZIONE e Specifiche Tecniche Dimensioni Altezza Larghezza Profondit Peso operativo 495 mm 297 mm 433 mm 17 Kg Specifiche Elettriche 230 V 50 Hz 180 VA Fusibile lento da 1 Ampere Specifiche Idrauliche Tubazione di alimentazione Pressione di alimentazione Portata di alimentazione Diametro esterno 8 mm Lunghezza massima 3 m Minima 0 03 bar 0 3 m colonna d acqua 1 5 litri min Prestazioni Portata acqua prodotta TOC 1 5 litri min 5 ppb misurato con Anatel A 100 P 2 INTRODUZIONE 2 INSTALLAZIONE e Disimballaggio Nell imballo del MILLI Q 185 PLUS troverete i seguenti articoli come da figura 3 A Unit MILLI Q 185 PLUS B Cavo di alimentazione C Coperchio per il punto d uso D Manuale operativo E Adattatore 1 2 Femmina a tubo da 8 mm con inserito un filtro a rete F Nastro di Teflon Articoli da ordinare separatamente G Blocco di purificazione Q PAK 1 H Filtro finale MILLIPAK 40 0 22 um Articoli G H N Cat CPMQKOBR1 e Posizionamento del MILLI Q 185 PLUS Il sistema MILLI Q 185 Plus pu essere posizionato su un banco da laboratorio o appeso a muro Per montare il sistema a muro necessar
80. riba y hacia el equipo Sujetando firmemente el equipo D con una mano sit e y empuje el QPAK E en su alojamiento con la otra mano balan ce ndolo ligeramente hasta que quede encajado Eleve y fije la aleta de sujeci n F INSTALLACION 3 OPERACION e Modos normales de operaci n El MILLI Q 185 PLUS tiene diversos modos operativos presentados en el display Unos deben ser activados mediante el teclado mientras que otros est n programados y son autom ticos MENSAJE EN PANTALLA ACCIONAMIENTO ESTADO DEL MILLI Q 185 PLUS STANDBY TEMPERATURE 25 C TEST MQ cm PRODUCT MQ cm TEMPERATURE C RECIRCULATION Presionando la tecla OPERATE STANDBY cuando el sistema est en modo de operaci n Presionando la tecla TEMPERATURE cuando el sistema est en modo de espera Presionando la tecla OPERATE STANDBY cuando el sistema est en modo de espera Aparece 4 segundos despu s del anterior tras presionar la tecla OPERATE STANDBY cuando el sistema est en modo de espera Presionando la tecla TEMPERATURE cuando el sistema est en modo de operaci n o de RECIRCULATION Se activa autom ticamente de forma peri dica cuando el sistema est en modo de espera En modo de espera standby sin consumir ni producir agua En modo de espera mostrando la temperatura de referencia la lectura de resistividad se presenta compensada a 25 C En modo de operaci n
81. ricas parte trasera del equipo Conexi n hembra REMOTE STANDBY Conexi n para clavija de control remoto Permite que un equipo externo por ejemplo un auto analizador modifique autom ticamente el modo operativo del equipo altern ndolo entre operaci n y espera en funci n de sus necesidades Para m s informaci n consulte a Millipore e Puesta en marcha figura 7 1 Verifique que el QPAK est bien instalado y que se han hecho todas las conexiones indicadas 2 Abra la llave de corte de la toma de agua pretratada 3 Sit e la v lvula de tres v as A en la posici n PRODUCTION 4 Sit e un recipiente B en la repisa del equipo bajo el punto de uso del agua C 5 Ponga el equipo en marcha accionando el interruptor principal ON OFF situado detr s del equipo ver componente P figura 1 La pantalla mostrar RECIRCULATION Si aparece BATTERY apague OFF el interruptor general durante dos segundos y enci ndalo ON de nuevo 6 Si hay un regulador de presi n instalado antes del equipo aj stelo para dar una presi n de salida de entre 0 5 y 1 bar mientras el equipo est en modo de producci n con el agua saliendo por el punto de uso 7 Deje el equipo en modo de producci n con la salida de agua purificada C abierta para eliminar el aire contenido en el equipo y en el bloque QPAK Cada vez que se llene el recipiente B cierre la v lvula de tres v as A para retirarlo y vaciarlo en un desag e 8
82. s or Distilled is driven by a built in pump through a chamber where the feedwater is exposed to ultraviolet light U V of low wavelength 185 nm 254 nm This initiates oxidation of dissolved organic compounds remaining from the prepurification process Reverse Osmosis or Distillation The U V irradiation also displays a bacteriocidal action The U V treated feedwater is then passed through the Q PAK purification element which removes the ionic compounds plus the by products of U V photooxidation A Built in three way valve allows recirculation of the water until the required water quality is achieved When the required water quality is reached turning the three way valve allows water to pass through the MILLIPAK 40 final filter unit at the point of use e Schematic The MILLI Q 185 PLUS system operating schematic is shown on figure 2 as follows A Inlet solenoid valve B Pump C U V lamp in external housing D Water purification pack Q PAK E Resistivity measurement cell to measure product water quality F Three way valve G Final filter Millipak 40 0 22 um H Check valve INTRODUCTION e Specifications Dimensions Height Width Depth Operating weight 495 mm 19 5 in 297 mm 11 7 in 433 mm 17 in 17 kg Electrical specifications 230 V 50Hz 180 VA Fuse 1 Amp slow blow Hydraulic specifications Feed water tubing Feed water pressure Feed water flowrate Ex
83. sicherung s Anhang 1 Ersetzen Sie die Platinensicherung s Anhang 2 Ersetzen Sie das Q Pak Siehe Kapitel WARTUNG Ersetzen Sie das Q Pak Siehe Kapitel WARTUNG Ersetzen Sie die Sicherung f r die UV Lampe auf der Platine siehe Anhang 3 Ersetzen Sie die UV Lampe Siehe Abschnitt WARTUNG Die interne Wassertemperatur ist zu hoch Siehe TEMPERATURE gt 35 C Lassen sie das System f r 48 Stunden eingeschaltet um die Batterie aufzuladen Schalten Sie danach f r 2 Sekunden das System aus um die Anzeige BATTERY zu l schen ST RUNGSBESEITIGUNG 11 Problem Grund L sung TEST INCORRECT wird angezeigt wenn das System den Autotest durchf hrt W hrend des PRODUCTION oder RECIRCULATION Modus wird Temperature gt 35 C angezeigt Auf der Anzeige erscheint Temperature lt 0 C oder Temperature gt C w hrend des OPERATE Modus Temperatur oder widerstand sind falsch kalibriert Die Wassertemperatur im System hat 36 C erreicht und mu auf lt 35 C gesenkt werden damit sich die UV Lampe wieder einschaltet Das System war zu lange im OPERATE Modus ohne daf Wasser entnommen wurde Die Speisewassertemperatur ist zu hoch Speisewassertemperatur ist gt 40 C Der Thermistor oder seine Anschl sse zur Widerstandszelle sind defekt Dr cken sie die Taste TEMPERATURE w hrend das System im STANDBY Modus steht TEMPERATURE 25 C sollte angezeigt werd
84. ternal diameter 8 mm Maximum length 3 M Minimum Positive head 0 3M 0 03 bar 0 5 psi Maximum 1 0 bar 15 psi 1 5 Litres min Performance Product water flow rate T O C Total Oxidisable Carbon lt 1 5 litres min lt 5 ppb typical value by ANATEL A 100 P 2 INTRODUCTION 2 INSTALLATION e Unpacking e Installation On unpacking the MILLI Q 185 PLUS you should find the following items INLET WATER CONNECTION FIGURE 5 as shown on figure 3 Feedwater stored in Reservoir A MILLI Q 185 PLUS unit B Power cord 1 Cut the feedwater tubing C to the desired length lt 3 m C Point of use mounting cover D Users manual 2 Remove the protective plug B from the INLET connection D by E RE 1 2 Female 8 mm 0 3 in tubing with built in screen pressing on collet A and pulling plug ilter F Teflon tape 3 Connect feedwater tubing C to the INLET connection by inserting Following items to be ordered separately the tube firmly into the fitting Verify that the connection is good by G Water purification Pack Q PAK 1 pulling back several times on the tube H Final filter unit Millipak 40 0 22 um Items G H Cat N CPMQKOSRI 4 Connect the tube to the valve on the outlet from the reservoir This valve should already be fitted with an adaptor to accept 8 mm diameter tubing e Positioning of MILLI Q 185 PLUS Feedwater delivered from a pressurized line in a distribu
85. tion the RECIRCULATION mode is also activated each time the unit is switched ON OPERATION 5 e Additional Displays DISPLAY STATUS OF MILLI Q 185 PLUS PRODUCT XX MQ cm TEST INCORRECT BATTERY EXCHANGE PACK U V This display indicates a resistivity value which is out of scale See TROUBLESHOOTING chapter Displayed when the Auto test result displayed is lt 14 MQ cm or gt 16 MQ cm See TROUBLESHOOTING chapter The battery on the P C board is discharged The data stored when the system was switched OFF has now been lost See TROUBLESHOOTING chapter Flashes when the Q PAK should be changed See MAINTENANCE chapter Continously illuminated when the Q PAK is not in place or incorrectly fitted See TROUBLESHOOTING chapter Flashes for 30 seconds when the U V lamp is first switched ON heating up of lamp Continously illuminated when the U V lamp is lit and its operating efficiency is at an optimum level e Use of Keyboard The keyboard allows the user to control the operating mode of the system and to display a number of preset parameters governing the correct function of the system DESIGNATION OF BUTTON FUNCTION OPERATE STANDBY Pressing on this button will successively activate the OPERATE and STANDBY modes TEMPERATURE During STANDBY mode pressing this button during STANDBY mode will cause the reference temperature 25 C to be displayed temperature compens
86. tion loop The MILLI Q 185 PLUS unit may be placed on a laboratory bench or wall mounted To mount the unit on the wall order the wall mounting bracket Cat N ZFMQOOWMB and verify that the wall is able to support the operating weight of the unit 17 Kg 1 If the pressure is gt 1 bar then the pressure should be reduced Use Pressure Regulator Cat N ZFMQOOOPR 2 Connect feed tubing C to the outlet of the pressure regulator Figure 4 shows the connection of the MILLI Q 185 PLUS with different feedwater delivery options reservoir or pressurized line NOTE The isolating valve on the pressurized line the pressure regulator and pressure gauge shown on figure 4 are not supplied with the system INSTALLATION 3 e Installation of purification pack Q PAK Figure 6 1 Swing the pack locking handle to the left by pressing on the locking tab and pulling down on the handle Remove the protective plugs A 2 Remove the protective caps B on the Q PAK 3 Wet the two O rings C of the pack with a few drops of water 4 Position the Q PAK in its cavity Hold the MILLI Q 185 PLUS D firmly and push home the Q PAK E if necessary use a slight side to side movement 5 Replace and lock the pack retaining arm F in position 4 INSTALLATION 3 OPERATION e Standard modes of operation The MILLI Q 185 PLUS displays several modes of operation Certain can be activated via the keyboard others are preprogrammed
87. to de uso con visera de protecci n C Filtro final Millipak 40 con membrana de 0 22 um D V lvula de tres v as E Panel de control F Aleta de sujeci n del bloque de purificaci n QPAK G Pilotos luminosos H Pantalla de cristal l quido I Teclado J Conector para entrada de agua K Tap n que cubre el orificio de adaptaci n de la escuadra para instalaci n mural L Tornillo de cierre de la cubierta trasera M Conexi n para clavija de control remoto N Entrada general de corriente O Porta fusible principal P Interruptor principal ON OFF Q Bloque disipador de calor e Funci n del equipo El agua de entrada previamente tratada mediante smosis inversa o destilaci n pasa en primer lugar a trav s de una bomba que la impulsa hacia la c mara de foto oxidaci n ultravioleta equipada con una l mpara U V de doble longitud de onda 185 y 254 nm cuya misi n es la oxidaci n de los residuos de materia org nica liberados por la etapa de pretratamiento La radiaci n U V presenta tambi n un efecto germicida A continuaci n el agua atraviesa un bloque de purificaci n QPAK que elimina todos los compuestos ionizados Una v lvula de tres v as permite al usuario recircular el agua hasta que sta alcance la calidad requerida momento en que basta con accionar la v lvula para obtener agua ultrapura en el punto de uso e Diagrama de flujos El esquema operativo de un MILLI Q 185
88. uando si accende la lampada U V per la prima volta riscaldamento della lampada Luce fissa quando la lampada U V accesa ed perfettamente efficiente e Utilizzo della Tastiera La tastiera permette all utilizzatore di controllare il modo operativo del sistema e visualizzare i parametri prefissati che governano il corretto funzionamento del sistema NOME DEL PULSANTE FUNZIONE OPERATE STANDBY Premendo questo pulsante si passa da OPERATE a STANDBY e viceversa TEMPERATURE Durante il modo STANDBY premendo questo pulsante durante il modo STANDBY si visualizza la temperatura di compensazione di 25 C temperatura di compensazione della resistivit Durante i modi OPERATE e RECIRCULATION premendo questo pulsante durante i modi indicati si visualizza la temperatura dell acqua prodotta Rilasciando il pulsante in entrambi i casi la temperatura rimane visualizzata per 3 secondi 6 FUNZIONAMENTO e Connessioni elettriche sul retro del sistema Presa REMOTE STANDBY Questa presa permette di controllare il MILLI Q 185 PLUS da un unit di comando remota Modo REMOTE STANDBY OPERATE Contattare l Assistenza Tecnica Millipore per ulteriori informazioni sull uso di questa funzione e Avviamento Figura 7 l Verificare che il Q PAK sia correttamente installato e che tutte le connessioni siano fatte correttamente Aprire la valvola dell acqua di alimentazione Posizionare
89. uch C auf die gew nschte Lange lt 3 m 2 Entfernen Sie die Schutzkappe B von der EinlaBverbindung D indem Sie auf den Klemmring A dr cken und den Stopfen herausziehen 3 Schlie en Sie den Speisewasserschlauch C an die Einlaf3ver bindung an indem Sie den Schlauch fest in die Schnellverbindung einstecken Stellen Sie sicher daf die Verbindung h lt indem Sie mehrmals am Schlauch ziehen A Verbinden Sie den Schlauch mit dem Ventil am Auslaf des Tanks Dieses Ventil sollte bereits mit einem Adapter versehen sein um einen Schlauch mit 8mm Durchmesser aufnehmen zu k nnen SPEISUNG AUS EINER RINGLEITUNG 1 Betr gt der Eingangsdruck mehr als 1 bar mu dieser reduziert werden Setzen Sie hierzu den Druckminderer Kat Nr ZFMQ 000 PR ein 2 Verbinden Sie die Speisewasserzuf hrung C mit dem Ausgang des Druckminderers INSTALLATION 3 e Einbau des Q Pak Aufbereitungsmoduls Abbildung 6 Entriegeln Sie den Sicherungshebel f r das Q Pak Modul indem Sie auf die VerschluBraste dr cken und den Hebel nach unten links ziehen Entfernen Sie die Schutzkappen A 2 Entfernen Sie die Schutzkappen B am Q Pak 3 Befeuchten Sie die zwei O Ringe C des Q Paks mit ein paar Tropfen Wasser 4 Setzen Sie das Q Pak in das System an die daf r vorgesehene Stelle ein Halten Sie das MILLI Q 185 PLUS System D mit einer Hand fest w hrenddessen Sie das Modul mit der anderen Hand in das System einschieb
90. uton OPERATE STANDBY Appui sur le bouton TEMPERATURE en mode de production ou RECIRCULATION Automatique L appareil est en tat de veille Affichage de la temp rature de r f rence 25 C Affichage de la calibration de l appareil 15 1 MQ cm pendant 4 secondes Affichage de la r sistivit de l eau mesur e pendant la production Affichage de la temp rature de l eau la sortie du pack de purification Fonctionnement s quenc de l appareil pendant le mode STANDBY pour maintenir la qualit de l eau 15 mn toutes les heures Le mode RECIRCULATION est activ chaque mise sous tension et 45 mn apr s le passage en mode STANDBY UTILISATION e Messages compl mentaires MESSAGES MIS ETAT DU MILLI Q PLUS 185 PRODUCT XX MQ cm TEST INCORRECT BATTERY EXCHANGE PACK U V S affiche lorsque la mesure de r sistivit est hors chelle Se reporter au chapitre MAINTENANCE S affiche lorsque l affichage test est lt 14 MQ ou gt 16 MQ Se reporter au chapitre MAINTENANCE Les informations sauvegard es lors de la derni re mise hors tension du MILLI Q 185 PLUS ont t perdues Se reporter au chapitre MAINTENANCE Clignote lorsque le Q PAK doit tre chang Se reporter au chapitre ENTRETIEN Allum lorsque le Q PAK n est pas en place ou mal engag Se reporter au chapitre MAINTENANCE Clignote pendant 30 secondes la mise sous tension de la lampe U V mont
91. uyant sur l interrupteur Marche Arr t voir figure 1 P L afficheur doit indiquer RECIRCULATION Si l affichage BATTERY apparait couper le secteur pendant 2 secondes Si l appareil est aliment travers un r gulateur de pression ajuster la pression de sortie entre 0 5 et 1 bar lorsque le MILLI Q 185 PLUS est en production vanne 3 voies A sur la position PRODUCTION Laisser l appareil en fonctionnement pour que l eau s coule en purgeant l air par le point de soutirage Contr ler le remplissage du r cipient avec la vanne 3 voies A 8 Apr s avoir soutir 5 7 litres d eau mettre la vanne 3 voies A sur la position RECIRCULATION appuyer 2 fois sur le bouton OPERATE STANDBY pour mettre l appareil en mode STANDBY Si possible laisser l appareil une nuit dans cet tat pour permettre aux composants du pack de se r hydrater 9 Le lendemain matin appuyer sur le bouton OPERATE STANDBY TEST MQ cm s affiche 4 secondes puis 2 secondes apr s le voyant U V clignote pendant 30 secondes avant d tre allum en permanence Pr lever 2 3 litres d eau Remettre l appareil en mode STANDBY en appuyant sur le bouton OPERATE STANDBY e Mise en place du filtre final MILLIPAK 40 Figure 8 Lorsque le Q PAK a t purg on peut proc der au montage du filtre MILLIPAK 1 Recouvrir le filetage A du filtre MILLIPAK avec 2 3 tours de ruban T flon B pour une bonne tanch it 2 Visser le
Download Pdf Manuals
Related Search
Related Contents
Naviguer eN toute sécurité - Voies navigables de France Cámara DIGItal a Color InalámBrICa aC Gemcad para Windows Versión 1.0 Manual del Usuario Istruzioni per l`uso ACM 812 - Migros Roche CoaguChek® XS METHOD AND SAMPLE Gamme céramique Matchmaker PRESS Flash N° 18 septembre 2012 SANI 300L KPS-X430 取扱説明書 Copyright © All rights reserved.