Home

MW4300.book - Sartorius AG

image

Contents

1. Service gt MWTest gt Compression test gt Press the graphic Graphic gt Settings or the Display 1 field i A Compression test 5 TEST GG Keyboard shortcuts for buttons in dialogs Apply Return or Enter Cancel Esc key Call online help F1 gx lt In the Product settings Sensor modes and MW devices tables double click on a table row to call the dialog for editing the values settings SHE sartorius 133 mechatronics WLM6009 a10081 LMA316PA LMA321PA Shortcuts 134 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA 15 Glossary Application You can use Sartorius moisture measurement devices to measure diverse products To increase the precision of measurements for special applications various sensors are available Pipe shaped measuring cells for laboratory use and bypass systems and slider shaped planar sensors for in process measurement Calibration The microwave resonance method returns a measurement signal correlated with the water content of the sample This means that the measured microwave values must be assigned to moisture values determined using a reference method direct method in a one off procedure The system then determines the function of regression automatically Calibration is very easy to carry out using the menu The user can choose between linear and non linear polynomial cali bration Colour independence Unlike infrared methods microwave r
2. ERE sartorius 231 a mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz 232 Grafik gt Drucken Die grafische Darstellung der Kalibration kann ausgedruckt werden Hinweise zum Anschluss eines Druckers finden Sie auf Seite 198 Wahlen Sie im Ment Kalibration gt Feuchte Kalibration gt Grafik gt Drucken Die Grafik wird so wie sie am Bildschirm dargestellt wird ausgedruckt Typeneinst Typeneinstellung Hier bestimmen Sie den Typ der Kalibration Wahlen Sie zwischen Einfach Experte auto Hinweis Sie erhalten den entsprechenden Dialog auch wenn Sie auf das Feld Anzeige 1 Kalib ration Typ Korrekturen dr cken Einfach Der Dialog erm glicht ein einfache Berechnung der Kalibration W hlen Sie aus dem Listenfeld entweder den einfachen Typ linear oder den Kalibrationstyp nichtlinear der entsprechend den verf gbaren Werten aus einem oder aus bis zu vier Segmen ten bestehen kann linear Die Kalibrationskurve ist eine gerade Linie nichtlinear Die Kalibrationskurve ist nicht unbedingt eine Linie Gegebenenfalls werden einzel ne Zonen der Kalibrationskurve durch Kurven dargestellt Hinweis Beachten Sie dass Sie f r einen komplexeren Kalibrationstyp entsprechend mehr Messwerte ben tigen Extremum F r den Kalibrationstyp nichtlinear bestimmen Sie hier ob ein Extremum in der Kurve vor kommt Markieren Sie die Option Extremum wenn Sie wissen dass einer der
3. Produkte werden ber den Men punkt Produkteinstellungen Details auf Seite 244 neu ange legt Hinweis Das aktuell gew hlte Produkt ist in der Spalte Nr mit einem gr nen H kchen markiert Dr cken Sie auf einen Spaltenkopf um die Tabelle zu sortieren Die aktuelle Sortierung wird durch einen Pfeil in einem Spaltenkopf angezeigt Dr cken Sie auf die Zeile mit dem Namen des Produktes f r das der Test durchgef hrt werden soll Hinweis Falls nicht alle Produkte angezeigt werden nutzen Sie die Schaltfl chen f r die Navigation Details auf Seite 212 Dr cken Sie auf bernehmen Der Verdichtungstest kann nun f r das gew hlte Produkt durch gef hrt oder bearbeitet werden Tabelle Die Messergebnisse des Tests werden als Tabelle angezeigt Dr cken Sie auf die Betriebsartanzeige Verdichtungstest oder das Grafik Symbol um zur grafi schen Darstellung umzuschalten Tabelle Bearbeiten Typ Sie haben die M glichkeit einzelne Punkte der Messkurve durch unterschiedliche Symbole darzustellen Markieren Sie einen oder mehrere Eintr ge Dr cken Sie auf Typ W hlen Sie den Typ des Messpunktes HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz Tabelle Bearbeiten L schen Sie haben die M glichkeit einzelne Punkte der Messkurve zu l schen 1 Markieren Sie einen oder mehrere Eintr ge 2 Dr cken Sie auf L schen VI Markierte Eintr ge werden gel scht
4. 0 212 0 208 4 Fe 0 204 0 200 4 ae 0 196 e 0 192 4 Be einfache Kalibrations ar kurve mit zwei Kalibra Be 0 180 42 tionspunkten 0 3 05 07 09 11 13 15 nichtlineare Kalibrati i onskurve mit E vier Segmenten 0 192 LT g 15 9 16 7 17 5 18 3 19 1 19 9 20 7 21 3 22 3 EES Hinweis Eine Kalibration kann durch Messen weiterer Proben auch nachtr glich verfeinert werden Dies ist besonders dann erforderlich wenn das Produkt sp ter in einem anderen Werte bereich gemessen wird Anmelden zum Kalibrieren bzw Anlegen von Produkten Um neue Produkte anzulegen oder f r Produkte eine Kalibration durchzuf hren m ssen Sie sich mit den entsprechenden Rechten Kalibration mind Stufe 3 Produkte neu anlegen mind Stufe 4 anmelden Dies verhindert unbefugtes ndern von Systemeinstellungen die zu fehlerhaften Messergebnissen f hren k nnten W hlen Sie den Men punkt Benutzerwechsel Geben Sie im Dialog Anmeldung Ihren Benutzernamen Nutzername und Ihr Passwort ein Klicken Sie auf bernehmen Die Funktionen Kalibration Produkteinstellungen Systemeinstellungen und Service sind jetzt verf gbar Hinweis Nachdem Sie administrative Arbeiten durchgef hrt haben sollten Sie sich wieder mit den Benutzerdaten f r den normalen Zugriff anmelden oder falls ein Standardbenutzer angelegt ist das Ger t ausschalten um unbefugte nderungen an
5. 5 Steuerung Uber externen PC 5 1 5 2 Die Mikrowellen Messger te der Baureihen PMD320PA PMD325PA und LMA316PA LMA321PA k nnen alternativ auch ber einen externen Windows PC gesteuert werden F r die Steuerung wird auf dem PC die Software TMV installiert Mithilfe von TMV k nnen Sie beispielsweise Daten auf den externen PC exportieren und Backups auf diesem PC speichern F r die Verbindung von Messger t bzw Auswerteeinheit und PC bestehen zwei M glichkeiten Direkter Anschluss des PCs an das Messger t ber ein Crossover Netzwerkkabel Einbindung des Messger ts in ein bestehendes Netzwerk ber TCP IP Die Einbindung in ein Netzwerk bietet zus tzlich folgende Vorteile Auswerteinheit und Steuerungs Arbeitsplatz k nnen r umlich getrennt werden z B Produkti onshalle B roraum ber einen PC k nnen mehrere Messger te gesteuert werden berblick F r die Steuerung ber einen externen PC sind folgende Arbeitsschritte notwendig TMV auf dem PC installieren Netzwerkkabel anschlie en entweder Crossover Kabel zwischen PC und Messger t oder Messger t an das bestehende Netzwerk anschlie en Auf dem externen PC einen Eintrag mit der IP Adresse des Messger ts anlegen und die Verbin dung aktivieren Installation der Software TMV Das Programm kann auf PCs mit den Betriebsystemen Microsoft Windows 2000 XP Vista genutzt werden Voraussetzungen Beenden Sie eventuell noch laufende Prog
6. CO C 2 Sensorkabel Standard bei Black Line Sensoren entf llt bei lte ren Sensor Typen Z O Netzwerk verbindung Netzkabel 9 110 230 V AC gt Temperatur GC A sensor Pt 100 a De U Kg S USB externer Monitor Tastatur und Maus O Hinweis Tastatur und Maus k nnen nicht ber die USB Anschl sse angeschlossen werden Die USB Anschl sse k nnen f r den Anschluss eines entsprechenden Druckers sowie den mitgelie ferten USB Speicherstick oder eine USB Festplatte verwendet werden SHE sartorius 155 mechatronics WLM6009 a10081 LMA316PA LMA321PA Inbetriebnahme 4 3 4 4 156 Anschluss eines Temperatursensors Pt 100 Der Pt 100 geh rt zum Standard Lieferumfang au er bei Ger ten die mit einem Sensor mit inte griertem Infrarot Sensor zur Temperaturmessung geliefert werden Achten Sie beim Einstecken auf die Fuhrungsnase im Stecker Stecken Sie den Stecker des Temperatursensors Pt100 in die mit dem Thermometer Symbol gekennzeichnete Buchse an der R ckseite des LMA316PA LMA321PA ein und schrauben Sie die berwurfh lse des Steckers fest Verwenden Sie zum Festziehen der Verschraubung kein Werkzeug Wenn Sie das Kabel wieder abzieh
7. Deactivated You have to click the 1st display panel again to recalculate the curve Deactivate this option if you still need to carry out considerable value editing You are then able to work more quickly since the calculation process always requires a certain amount of time If individual values are removed or changed it may mean that the curve can no longer be calculated If this is the case the system issues an error message With limits Activated The limits of the non linear zones are recalculated for every change Deactivated The limits of the non linear zones are maintained when changes occur Optimized manual correction Activated Measured temperatures are taken into account Deactivated Measured temperatures are not taken into account HE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 13 6 Product settings This is where the data set for anew product is entered This is where the parameters for a product are changed This menu has the following sub items Edit Details on page 103 Settings Details on page 106 Print Details on page 106 Export Details on page 106 The currently selected product is indicated by a green tick Edit You can change the parameters for a product This menu has the following sub items Values Details on page 103 Delete Details on page 104 Copy Details on page 104 New Details on page 104 Sel
8. EE sartorius 9s seg 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Other functions 56 10 The various settings such as paper format or print quality can be specially selected for each print order In Printer Options define which of the standard settings you want If you change the settings press Set Printer Options to implement the changes You can now set up other printers delete printers define a printer as the default printer or edit the default settings see Editing the printer settings on page 56 by choosing Back to return to the Administration tab Press Close to close the Printer Configuration dialog Editing the printer settings Basic operation You call up the Printer Configuration dialog by choosing System settings gt Configuration gt Printer config After ending the settings choose Close to close the dialog Remove the printer from the list You can remove printers that are no longer required from the list of available printers Under Printer in the list select the printer that you want to delete Press Delete Printer lt Name gt The printer is deleted without any further query Define a printer as the default printer If several printers are set up as possible output devices the first printer in the list is used as the default printer However you can also set any other available printer from the list as the default printer Select the required printer under Printer in the
9. Seite 210 zum Markieren einer oder mehrerer Zeilen Dr cken Sie auf eine Zeile um diese zu markieren EE sartorius a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz O Hinweis Sie k nnen mehrere Zeilen markieren 2 Dr cken Sie auf die Schaltfl che Drucken Ch Die markierten Tabellenzeilen werden ausgedruckt x 3 Drucken Sie auf SchlieRen Das Drucken der Werte ist beendet Export Die Tabelle wird im Format csv exportiert und auf dem angeschlossenen USB Stick gespeichert EZ 1 Dr cken Sie auf Bearbeiten um den Dateinamen zu ndern O Hinweis Wenn Sie das Programm am PC nutzen erhalten Sie den Dialog Export Hier w hlen Sie einen Speicherort auf dem PC und hier ndern Sie gegebenenfalls den Namen der Exportdatei O Hinweis Microsoft Excel 2003 Das weit verbreitete universelle Exportformat csv ist f r Excel 2003 nicht richtig zu interpretieren Benennen Sie die csv Datei in txt um und importieren Sie sie in Excel 2003 mit der Importfunktion SHE sartorius 217 cece x mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz ll III Statistik Sie k nnen zu ausgew hlten Eintr gen in der Tabelle eine Statistik erstellen Nachdem Sie auf Statistik gedr ckt haben stehen entsprechende Schaltfl chen zur Verf gung Lesen Sie dazu Schaltfl chen Messung Kalibration Details auf Seite 210 Markieren Sie entweder einen
10. W hlen Sie unter Device den USB Drucker aus und dr cken Sie auf Next W hlen Sie im Register Make Model Driver zun chst unter Make den Druckerhersteller und anschlie end unter Model den Typ des USB Druckers aus Dr cken Sie auf Add Printer lt Name gt Der USB Drucker wird der Liste der in TMV verf g baren Drucker hinzugef gt Nach Dr cken auf OK in der Meldung dass der Drucker angelegt wurde erscheint das Register Printer Options in dem Sie die Voreinstellungen f r den Drucker festlegen k nnen Die m gli chen Optionen sind abh ngig vom jeweiligen Druckertreiber Falls nicht alle Optionen auf einmal dargestellt werden k nnen k nnen Sie ber die Schaltfl chen Up und Down zu den weiteren Optionen wechseln Die verschiedenen Einstellungen wie Papierformat oder Druckqualit t k nnen bei jedem Druck auftrag gesondert ausgew hlt werden Hier in den Printer Options legen Sie lediglich fest welches die Standardeinstellungen sein sollen Falls Sie Einstellungen ge ndert haben dr cken Sie auf Set Printer Options um die nderun gen zu bernehmen Sie k nnen jetzt noch weitere Drucker anlegen Drucker l schen als Standarddrucker definieren oder die Voreinstellungen bearbeiten siehe Bearbeiten der Druckereinstellungen auf Seite 201 indem Sie auf Back dr cken um zum Register Administration zur ckzukehren Dr cken Sie abschlie end auf Close um den Dialog Printer Configuration zu schlie en Bearb
11. You specify the number of decimal places to be displayed for the shown measured values mois ture density and temperature and for the shown measured calibration values Press a list field Press the number you require Note Regardless of what is actually displayed all values are stored in the system with a consid erably higher level of accuracy Status line Extended Activate this option to define an extended status bar display Select Moisture and or Density if you want these values to appear in the status line Font size Specify the font site for status bar display Virtual keyboard x Option activated Values and text can only be entered using the virtual screen keyboard g Option deactivated A simple input field is displayed instead of the virtual keyboard Val ues and text are entered using the connected keyboard Full screen This option can only be used if you have TMV on an external PC since on touch screen devices the TMV window is always adapted in line with the screen Option activated The TMV window is automatically adapted in line with the screen Xi Option deactivated The TMV window is opened in the standard size or with the window size last set by the user Finally press on Apply The settings take effect immediately Global settings This dialog is for specifying various general settings There are several tabs in the top part ofthe dialog MW device Temperature and Analog outputs Pres
12. uueesenseeeneeennnnneenneennnnennnneeennnn 31 MW device cnan 109 N Network settings 114 New Calibration value 88 Connected device e 113 Product see ser 104 O OSet ee 105 Display 69 P Printer configuration ues een 53 Printerselu p EE 53 PlOGUGE EE 69 Create EE 20 Edit settings 103 Memory cells 31 Protected SITE se had alan ed ae 103 Product choice Calibration 84 119 Measurement 73 Product settings 31 103 R Reading eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaeeeeseeeeeeeeeeeeaaaees 80 Reference standard ccccccseseceeeeeeeeseeeeeeeeeees 70 Reference values ccccccceceseececeeeeseeeseeeeeeeaeees 37 Ke EE 71 EE ee EA 123 FRESLONG Aa Ee 60 Run Program EEN ee 19 S Sensor MOE een 31 Sensor Modes uuuussnnneeeeennnnnennnennnnnnnnn nennen 50 LIDA 2 222240 ae 111 Settings Global 2 2 2a en 108 ET EI e W 78 Graph compression test 120 Shortcuts 131 138 LMA316PA LMA321PA Index Soft adjustment nen 70 Start Controli oe Nee NN Net NNN Ae 8 NN NN NN 70 Measurement 45 RS 11 VS ane BO PERF aar EE 67 Stop Control 70 Measurement 45 Symbol Calibration point 87 95 T Table Copy enn 71 75 Create statistic 71 Delete ent 71 75 Edit e caer a aed nee ee 71 Hide column 126 Highlight block 71 Move column 126 Remark 75 SONN REENEN 126 Table vieW aaa 74 Te
13. Bearbeiten Extract Das Extrakt der Grafik d h die Steigung der Regressionslinie wird als ein Messpunkt mit einer entsprechenden Bemerkung in die Kalibration bertragen SHE sartorius 263 cece mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz 264 Grafik Einstellungen Verdichtungstest Eigenschaften Hinweis Im Feld Anzeige 1 werden die wichtigsten Einstellungen f r den Verdichtungstest angezeigt Dr cken Sie auf dieses Feld um den Dialog Verdichtungstest Eigenschaften zu erhalten Bereiche Bestimmen Sie hier die Parameter f r die Messbereiche in denen Messwerte gewonnen werden sowie f r den Messbereich der den Leerzustand des Sensors beschreibt bertragen an Sensormodus Der gew hlte Sensormodus wird den Testergebnissen angepasst Regression Scale Graph Type Bestimmen Sie hier Parameter um die Darstellung der Grafik anzupassen Grafik Drucken Die grafische Darstellung der Messwerte kann ausgedruckt werden Hinweise zum Anschluss eines Druckers finden Sie auf Seite 198 Die Grafik wird so wie sie am Bildschirm dargestellt wird ausgedruckt Messung Hinweis Im Feld Anzeige 2 werden die Messungseinstellungen f r den Verdichtungstest angezeigt Dr cken Sie auf dieses Feld um den Dialog Messungseinstellungen zu erhalten Bestimmen Sie hier Parameter zur Vorgehensweise bei der Messung continously Aktivieren Sie diese Option wenn fortlaufend Messwerte
14. Default user Select this option if you wish to make the current user the default user You can only do this if no other default user has been defined You may need to deactivate this option for the current default user before defining a new one Reset All entries are deleted from the input dialog Apply All changes are saved Macro settings Note You need to be logged on with at least level 4 access rights to change these settings In this area the settings for various basic functions can be changed and in some cases deacti vated The available settings differ depending on the device type Choose System settings gt Macro settings The installed macros are listed in a table along with their name value and availability status Illustrated example TM Eee LA Feuchte 0 75 243c EI Hilfe Chronik Makro settings Version 2 43 No Data over modbus TCP Data over ser link Data over server IP address 172 28 20 28 Max freq dev of ES adjust MHz 0 01 Maximum emptying time sec 30 Maximum filling time sec 30 Maximum measurement time sec 28 Temperature measurement pause sec 5 xi el sielel s ela Wait for stable temperature sec Note The available macros depend on the type of the measuring device The macro settings dialog is only available in English Select the macro whose settings you want to change and press Edit Information
15. EE sartorius a mechatronics WLM6009 a10081 LMA316PA LMA321PA Control via external PC 22 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA 5 Startup 5 1 Instructions for setting up the system The microwave cables can be up to 3 metres long special design but the standard cables are 1 metre long The evaluation unit must therefore be fairly close to the sensor The rear device feet are for setting the LMA316PA LMA321PA down during transport but not for positioning the connected device since this can damage the cables Place the LMA321PA into position and fold down the handle if the LMA321PA is to be positioned on a slight slant to make it easier to use Touchscreen Cable connections Handle If an external monitor is to be placed on the device it cannot be positioned on a slant Make sure that it is easy to read the screen by tilting the monitor If using an external monitor you also require an external mouse and keyboard Note Prior to moving the LMA316PA LMA321PA switch it off and remove all cables from the rear of the device HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Startup 5 2 24 gt an co ao CEO Connecting the instrument Connection diagram Basic configuration laboratory version Sensor S 2x microwave cables EE O o max 3 m O O Sensor cable standar
16. Operator Interface Reference Values You use this type of depiction to show one or two currently measured values clearly The currently measured value is displayed You cannot navigate between measured values You can stop and restart the measurement process QO You can carry out an empty adjustment amp 1 Press the Measurement mode display or the gearwheel symbol to display the graph instead of the table Settings Value 1 Press one of the two list fields to select the measured values to be displayed 2 Choose from the following Moisture Density Temp temperature Off no display only possible in the second panel 3 Choose from the following Last The last determined and stored value is displayed In certain circumstances this value is an av erage of several measurements Status line The value displayed in the status line is shown This value corresponds to the currently measured value In some circumstances this value is not stored This setting applies to both displays 4 Press Apply The values are displayed in accordance with the selected settings 80 SEE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 1 1st display 2nd display At the top right of the screen there are two panels for displaying analog readings or statistical values as required Settings for what is displayed in these fields can be made independently of
17. Tabelle Bearbeiten Kopieren Sie haben die M glichkeit einzelne Punkte der Messkurve zu l schen 1 Markieren Sie einen oder mehrere Eintr ge 2 Dr cken Sie auf Kopieren fe Markierte Eintr ge werden kopiert und in die Tabelle eingef gt Tabelle Einstellungen Sie erhalten den Dialog Einstellungen Die Darstellung der Tabelle zur Anzeige der Kalibration kann hier individuell angepasst werden Lesen Sie hierzu Einstellungen f r Tabellen Details auf Seite 269 Tabelle Drucken Ausgew hlte Messwerte k nnen ausgedruckt werden Hinweise zum Anschluss eines Druckers finden Sie auf Seite 198 W hlen Sie im Men gt Verdichtungstest gt Tabelle gt Drucken Die Tabelle wird nun im Modus zum Drucken angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen Seite 210 zum Markieren einer oder mehrerer Zeilen 1 Dr cken Sie auf eine Zeile um diese zu markieren O Hinweis Sie k nnen mehrere Zeilen markieren 2 Dr cken Sie auf die Schaltfl che Drucken Ch Die entsprechenden Tabellenzeilen werden ausgedruckt x 3 Dr cken Sie auf Schlie en Das Drucken der Werte ist beendet Grafik Die Messergebnisse des Tests werden als Grafik angezeigt Dr cken Sie auf die Betriebsartanzeige Verdichtungstest oder das Tabellen Symbol um zur ae Tabellenansicht umzuschalten 1 Dr cken Sie auf die Grafik um den Dialog Verdichtungstest Eigenschaften Details auf Seite 264 zu erhalten Grafik
18. W hlen Sie nun mithilfe der Schaltfl che Block 1 Block 2 mehrere Werte aus oder markieren Sie einzelne Eintr ge Dr cken Sie auf Kopieren W hlen Sie im Dialog Kopieren nach ein Produkt W hlen Sie ob die markierten Werte in die Kalibration des Produktes oder zum Verdichtungs test kopiert werden sollen Es werden nur die Messwerte nicht aber die Referenzwerte kopiert Dr cken Sie auf Schlie en Der Kopier Modus ist beendet SHE sartorius 237 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz 238 Neu Sie erhalten den Dialog Kalibrationseigenschaften Sie erstellen unabhangig von gemessenen Werten einen neuen Eintrag in der Kalibrationsta belle Jeder Wert kann Uber diesen Dialog eingegeben werden Drucken Sie auf ein Eingabefeld und Sie erhalten den Dialog zur Zahleneingabe Details auf Seite 268 bzw zur Texteingabe Details auf Seite 267 Dr cken Sie auf bernehmen um den Eintrag in der Tabelle anzulegen Beispiel Ein Wert wurde irrt mlich gel scht und muss manuell wieder eingegeben werden Werte aus anderen Kalibrationen werden zum Vergleich bernommen Tabelle gt Einstellungen Sie erhalten den Dialog Einstellungen Die Darstellung der Tabelle zur Anzeige der Kalibration kann hier individuell angepasst werden Lesen Sie hierzu Einstellungen f r Tabellen Details auf Seite 269 Tabelle gt Drucken Ausgew hlte Kalibrationswerte k nnen ausgedruckt werden
19. You are using a sensor of an older type or for any other reason your sensor is not connected to port Sensor 1 2 of your LMA3xxPA PMD3xxPA In this case the sensor modes will not be rec ognized automatically and you will have to manually define them yourself using the sensors data sheet as a basis Choose System settings gt Configuration gt Sensor modes gt Edit gt Create and transfer the information from the data sheet to the Sensor mode dialog fields Press Apply to have the new sensor mode available for measuring products Requirements have changed because the sensor has been modified e g due to dirt or because of new or modified samples not covered by the existing modes In this case you would copy an existing sensor mode and adapt the copy as appropriate Choose System settings gt Configuration gt Sensor modes gt Edit gt Copy Pick a sensor mode from the table that is suitable to act as a basis for the new sensor mode then press Copy A copy of the sensor mode will be added to the list under the same name as the original mode Choose System settings gt Configuration gt Sensor modes gt Edit gt Values Go down the list select the new copied sensor mode and press Values On the Sensor mode page adapt the parameters as appropriate In order to avoid confusion you are strictly recommended to change the Name of the sensor mode Press Apply to have the new sensor mode available for measuring products Wh
20. darstellung Der Bereich Messung wird mit der zuletzt gew hlten Darstellungsart angezeigt Umschalten der Anzeige zwischen Grafik Tabelle und ggf Werteanzeige Messung gt Grafik bzw Tabelle Dr cken Sie auf die Anzeigefl che der Betriebsart Messung gt Werte a A Kalibration gt Feuchte bzw Dichte gt Grafik bzw Tabelle 4 MyProduct zen Service gt MWTest gt Verdichtungstest gt Grafik bzw Tabelle K Aufrufen des Dialogs Werte Einstellungen Messung gt Werte gt Einstellungen Dr cken Sie auf eines der beiden Anzeigefelder ber diesen Dialog k nnen Sie ausw hlen welche Werte in den beiden Feldern angezeigt werden sollen Feuchte Dichte Temperatur keine Anzeige p ge 7 22 Aufrufen des Dialogs Produktauswahl Messung gt Produktauswahl Dr cken Sie auf den Produktnamen Kalibration gt Produktauswahl a Service gt MWTest gt Measurement Verdichtungstest gt Produktauswahl 2 sartorius 275 seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA Schnellzugriffe Shortcuts Dialog Einstellungen f r die Grafikdarstellung Messung gt Grafik gt Einstellungen Dr cken Sie auf eine der beschrifteten Achsen Kalibration gt Feuchte gt Grafik gt Einstellungen Direkteingabe des Offsets f r die Feuchte Der Feuchte Offset wird im Dialog Produktei Dr cken Sie auf die Anzeige des Feuchte Offsets genschaften ge ndert Aufruf ber Produk
21. Anzeige 2 Kalibrationstyp Werte 1 Dr cken Sie auf das Feld Anzeige 1 um den Dialog Kalibrationstyp einfach zu erhalten Aus diesem Dialog heraus oder auch ber das Men erhalten Sie einen weiteren Dialog mit Ex perten Einstellungen Kalibrationstyp Sie haben die M glichkeit die Kalibrationskurve anzupassen Falls f r das gemessene Produkt zwischen Referenzfeuchte und gemessener Feuchte keine direkt proportionale Beziehung besteht w hlen Sie hier einen nichtlinearen Kalibrationstyp Da Produkte f r verschiedene Messbereiche unterschiedliches Verhalten aufweisen k nnen haben Sie die M glichkeit die Kalibrationskurve in verschiedene Segmente aufzuteilen Im einfachen Kalibrationsmodus wird die Unterteilung in Segmente automatisch ermittelt Bestimmen Sie hier ob die Kalibrationskurve einen Extremwert aufweist und in welcher Form Temperatur und Dichte bzw Feuchte ber cksichtigt werden sollen F r komplexe Kurven sind entsprechend viele Messwerte notwendig Falls Messwerte Referenzwerte oder Korrekturwerte nicht den in den globalen Einstellungen gt Seite 234 festgelegten Bereich abdecken erhalten Sie eine Fehlermeldung ndern Sie die Einstellungen f r die Messbereiche oder nehmen Sie weitere Kalibrationsmessungen vor SHE sartorius 177 cece 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Kalibrieren 178 Expertenmodus Aus dem Dialog Kalibrationstyp heraus k nnen Sie den Expertenmodus aufrufen
22. Read Details on page 112 Edit Values Note You need to be logged on with at least level 4 access rights to change these settings Press a row to select it Note You can select and edit several rows at a time You cannot change automatically loaded sensor modes Press the control to start editing The Sensor mode dialog is displayed Press an input field The Numerical input Details on page 125 or Text input Details on page 124 dialog appears Press Library Select a sensor mode from the list The properties of the selected sensor mode are copied to the dialog box and can now be edited EE sartorius e H mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference I 5 Press Apply to accept the changes x 6 Press Close The editing of the values is complete Delete O Note You need to be logged on with at least level 4 access rights to change these settings You can delete a sensor mode you created yourself from the list You cannot delete automatically loaded sensor modes 1 Select Delete from the Edit menu The table is now displayed in delete mode i e the controls gt page 70 for selecting one or more rows are displayed at the bottom Press a row This selects the sensor mode Press Delete The sensor mode is deleted without a safety prompt 4 Press Close The deletion process is complete Sep Copy O Note You need to be logged on with at least level 4 acces
23. W hlen Sie im Men Messung gt Kalibration gt Tabelle gt Drucken Die Tabelle wird nun im Modus zum Drucken angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen Seite 210 zum Markieren einer oder mehrerer Zeilen Dr cken Sie auf eine Zeile um diese zu markieren Hinweis Sie k nnen mehrere Zeilen markieren Dr cken Sie auf die Schaltfl che Drucken Die entsprechenden Tabellenzeilen werden ausgedruckt Dr cken Sie auf Schlie en Das Drucken der Werte ist beendet Tabelle gt Export Die Tabelle wird im Format csv exportiert und auf dem angeschlossenen USB Stick gespeichert Dr cken Sie auf Bearbeiten um den Dateinamen zu ndern Hinweis Wenn Sie das Programm am PC nutzen erhalten Sie den Dialog Export Hier w hlen Sie einen Speicherort auf dem PC und hier ndern Sie gegebenenfalls den Namen der Exportdatei Hinweis Microsoft Excel 2003 Das weit verbreitete universelle Exportformat csv ist f r Excel 2003 nicht richtig zu interpretieren Benennen Sie die csv Datei in txt um und importieren Sie sie in Excel 2003 mit der Importfunktion Grafik Die Grafik der Kalibration dient nur zur Anzeige Werte k nnen hier nicht ver ndert werden Bei aktivierter Option Korrektur kann die Korrektur f r Temperatur und oder Feuchte mittels Schie beregler oder Zahleneingabe angepasst werden RE sartorius e H mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referen
24. are recorded at certain intervals we recommend taking at least 6 measurements Continuous online measurement e g for bulk goods that pass by the sensor on a belt conveyor Bypass measurement in which defined sample quantities to be measured are diverted from the main flow and sent to the sensor at regular intervals After the measurement the sample is auto matically fed back into the main flow and the sensor is cleaned 2 sartorius gt coe mechatronics WLM6009 a10081 LMA316PA LMA321PA Calibration 10 11 amp 36 12 13 Calibration for single and multiple measurements laboratory Note For optimum calibration results see the calibration tips on page 29 Turn on the device if it is not already turned on The switch is on the back of the device If the device is already in operation stop the current measurements Select the Calibration menu item Now select the Product choice menu item Protected products are indicated by a lock You cannot alter the calibration of a protected product Select the required product in the Product choice dialog and click Apply In the Calibration menu select Moisture calibration or Density calibration We recommend that you use the table view default setting to clearly display the measured cal ibration values If this view is not already set choose Table to switch to the table view Note If calibration data already exists for the selected product the
25. bernehmen Dr cken Sie auf Zeigen um zur grafischen Darstellung bzw zur Tabellenansicht zur ckzu kehren Dr cken Sie in der grafischen Darstellung bzw in der Tabellenansicht auf Speichern um die Kali bration zu speichern oder kehren Sie wieder zum Dialog mit den Experteneinstellungen zur ck Hinweis Wenn Sie das Programm am PC nutzen dr cken Sie auf bernehmen um die Einstellung zu bernehmen Dr cken Sie auf Einfach um zur einfachen Kalibration zur ckzukehren Dr cken Sie auf Liste um die Parameter f r die gew hlte Kalibration als Liste angezeigt zu bekommen EE sartorius a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz auto Die Kalibration wird automatisch berechnet Falls Sie Einstellungen zur Berechnung der Kalibra tion andern wollen drucken Sie auf das Feld Anzeige 1 Kalibration Typ Korrekturen Sie erhalten dann den Dialog zur einfachen Berechnung der Kalibration 2 Seite 241 Optionen Dichtewerte Mindestbereich Hier legen Sie fest wie gro der Abstand zwischen zwei Werten sein muss damit diese f r die Kalibration als g ltig gelten Dies geschieht separat f r den Kalibrations Messwert den Refe renzwert den Korrekturwert und den Temperatur Korrekturwert Diesen Dialog erhalten Sie ebenfalls indem Sie auf das Feld Anzeige 2 Korrelation Std Abw Werte dr cken Automatische Berechnung x aktiviert Nach jeder nderung an den Wer
26. en beenden Hinweise zur Bedienung der Software Sie bedienen die Software TMV entweder ber die Bedienfl che Touchscreen durch direktes Ber hren der Schaltfl chen mit dem Finger ber eine zus tzlich angeschlossene Maus und Tastatur oder ber Maus und Tastatur an einem externen PC Eine bersicht ber die Befehls Schaltfl chen finden Sie ab Seite 210 Bedienung des Touchscreens nur LMA321PA Bei der Bedienung ber den Touchscreen an der Auswerteeinheit ber hren Sie die Schaltfl chen direkt mit dem Finger oder speziell daf r vorgesehenen Stiften Vorsicht Verwenden Sie zum Ber hren des Touchscreens keine scharfkantigen Gegenst nde wie Schraubenzieher Kugelschreiber o Diese k nnen die Oberfl che besch digen Die Eingabe von Buchstaben oder Zahlen erfolgt ber entsprechende Eingabedialoge Seite 267 Um einen Men punkt auszuw hlen oder einen Befehl auszuf hren dr cken Sie auf die entspre chende Fl che Hinweis Der Mauszeiger ist immer sichtbar auch wenn keine Maus angeschlossen ist Der Mauszeiger wird an die Stelle gesetzt an der die Bedienfl che ber hrt wird Bedienung mit Maus und Tastatur In folgenden F llen kann bzw muss das Ger t mit Tastatur und Maus bedient werden LMA316PA Diese Ger te haben keinen integrierten Touchscreen und m ssen ber Maus und Tastatur bedient werden da der extern angeschlossene Monitor keine ber hrungsempfindliche Oberfl che hat LMA321PA Be
27. from Start gt Programs This folder also contains a link to the uninstaller should you wish to remove TMV from the PC Click on Next when you are done The installer then asks you whether to place a link to the TMV executable on the PC s desktop or quick launch bar which you can later click to run the application you can also say whether this setting is to apply to all users or just the user who is currently logged on Click on Install TMV will be installed on your PC HE sartorius tee mechatronics WLM6009 a10081 LMA316PA LMA321PA Control via external PC Ot Setup IUS Completing the TMY Setup Wizard TMY has been installed on your computer Click Finish to close this wizard sartor Run THY Finish Cancel 10 On the final installer screen click on Finish O Note If the measuring device and the PC are already connected there will be an extra option Run TMV if you wish to start TMV immediately e g if you merely updated an earlier version of TMV or if you wish to set the IP address in TMV next see page 21 To run the software later GZ check the desktop for the TMV program icon and double click on it or select Start gt Programs gt TMV gt TMV from the menu orclick on TMV in the quick launch bar If the measuring device is not connected yet you will get error messages O Note Refer to section Operator Interface Reference from page 65 to
28. gt Programme gt TMV gt Uninstall Pr fen Sie im Startdialog des Deinstallationsprogramms das Verzeichnis Wenn es sich um die zu entfernende Installation von TMV handelt klicken Sie auf Uninstall Das Programm wird nun ohne weitere R ckfrage von diesem PC entfernt Hinweise zur Bedienung von TMV TMV zur Nutzung auf dem PC unterscheidet sich in der Bedienung nur geringf gig von der in dieser Anleitung beschriebenen Touchscreen Oberfl che Statt der virtuellen Bildschirmtastatur erhalten Sie Eingabefelder in die Daten direkt mit der PC Tastatur eingegeben werden Beim Exportieren von Daten und beim Speichern Wiederherstellen von Backups erhalten Sie den Dialog zur Bestimmung eines Speicherortes Exporte k nnen an jedem im Netzwerk erreich baren Speicherort gesichert werden In vielen F llen profitieren Sie von der Windows Funktionalit t e Dialoge k nnen verschoben werden Das Programmfenster kann in der Gr e angepasst werden Die Windows Zwischenablage Copy amp Paste ist aktiv Viele Funktionen k nnen per Doppelklick gestartet werden Der Befehl Drucken ruft den Druckdialog am PC auf Gedruckt wird mit einem am PC ange schlossenen Drucker oder einem Netzwerkdrucker EE sartorius a eegg mechatronics WLM6009 a10081 LMA316PA LMA321PA Steuerung Uber externen PC Sie beenden das Programm mit Service gt Schlie en O Hinweis Einen berblick ber Schnellzugriffe Shortcuts die die
29. her liegt Der Offset wird in den Produktparametern festgelegt 1 W hlen Sie ggf das Produkt f r das Sie einen Offset eingeben m chten 2 Dr cken Sie auf das Feld Feuchte Offset Kalibration Feuchte Kalibration berechnet Korrelation 1 0000 S Fouche geet Ip nichtlinear 1 Std Abw 0 0000 3 Cigarettes CY 41 Geld rrekturen 0 ext Werte 6 EES gt j Ber d SM D as 3 Geben Sie ber die Tastatur einen Wert f r den Feuchte Offset ein und dr cken Sie auf ber I nehmen O Hinweis Wollen Sie neben dem Feuchte Offset auch einen Offset f r die Dichte festlegen k nnen Sie dies ber den Dialog Produkteigenschaften einstellen Aufruf ber Produkteinstel lungen gt Bearbeiten gt Werte Beim Offset handelt es sich um einen absoluten Wert Wenn Sie als Offset z B 0 5 eingeben so wird f r gemessene Werte von 10 und 11 stattdessen 10 5 und 11 5 angezeigt Analog w rde f r einen Dichte Offset statt 10 g m der Wert 10 5 g m angezeigt 176 EE sartorius e H mechatronics WLM6009 a10081 LMA316PA LMA321PA Kalibrieren Kalibrationskurve anpassen O Hinweis W hrend der Kalibration werden in den Feldern Anzeige 1 Anzeige 2 Parameter und Einstellungen angezeigt Kalibration Feuchte Kalbration berechnet Korrelation 1 0000 Typ nichtlinear 1 Std Abw 0 0000 e Feuchte Off 3 Cigarettes CY 41 ke 0 000 Korrekturen 0 ext Werte 6 riesen Anzeige 1
30. im Dialog Sensormodus Aufruf Uber den Mentbefehl Systemeinstellungen gt Konfiguration gt Sensormodi gt Bearbeiten gt Werte oder wahlen Sie einen anderen Sensormodus im Dialog Produkteigen schaften Aufruf ber den Men befehl Produkteinstellungen gt Bear beiten gt Werte 2 0 4 Signal zu stark Fehlerhafter Sensor oder MW Hardware 2 0 5 Zu starke Signaldampfung Vergr ern Sie den Max A Dev Parameter Men befehl Service gt MW test gt MTask Test Register Parameter Die Genauigkeit der Messung wird dadurch reduziert 2 0 6 Zu groRe ADC Abweichung Vergr ern Sie den Max A Dev Parameter Men befehl Service gt MW test gt MTask Test Register Parameter Die Genauigkeit der Messung wird dadurch reduziert 2 0 7 Resonanzkurve instabil Vergr ern Sie den Stability MHz Parameter Men befehl Service gt MW test gt MTask Test Register Parameter Die Genauigkeit der Messung wird dadurch reduziert 2 0 8 Kein Maximum der Resonanzkurve gefunden Pr fen Sie mit der Funktion Start Sweep Men befehl Service gt MW test gt MTask Test Register Res Curve ob eine Resonanzkurve zwischen der Start und Stop Frequenz zu sehen ist 2 0 9 Sensormodus falsch gew hlt oder Hardware Fehler Pr fen Sie mit der Funktion Start Sweep Men befehl Service gt MW test gt MTask Test Register Res Curve ob bei der Backgr Fr keine Resonanz kurve vorkommt 2 0 10 PLL Fehler H
31. nnen Start Messung starten W hrend der Kalibration starten Sie hiermit eine Referenzmessung Stopp Messung stoppen Speichern Speichert den momentan angezeigten Wert Leerabgleich Dr cken Sie auf diese Schaltfl che um zu best tigen das der Sensor im Moment leer ist O O Sie werden gefragt ob ein harter oder ein weicher Leerabgleich erfolgen soll weicher Leerabgleich Sie teilen dem Ger t mit dass der Sensor jetzt leer ist bzw ein leerer Mess becher im Sensor platziert ist harter Leerabgleich Wenn nach l ngeren Messperioden die Ergebnisse ungenau oder verf lscht erscheinen empfiehlt sich ein harter Leerabgleich Auch hier wird dem Ger t mitgeteilt dass der Sensor jetzt leer ist Gleichzeitig werden intern einzelne Parameter angepasst so dass z B Materialverschlei am Sensor oder am Messbecher neu ber cksichtigt wird Der absolute Leerpunkt wird neu ge setzt Um einen Leerabgleich durchzuf hren m ssen Sie mit den entsprechenden Rechten am Ger t angemeldet sein Referenzstandard Diese Funktion dient zur technischen berpr fung der Anlage anhand eines opti onal erh ltlichen Referenzk rpers Weitere Informationen hierzu finden Sie auf Seite 203 Um diese Funktion auszuf hren m ssen Sie mit den entsprechenden Rechten an der Software angemeldet sein HE sartorius coe mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz Die folgenden S
32. teinstellungen gt Bearbeiten gt Werte Measurement 4 MyProduct Den Bemerkung zu einem Messwert eingeben Messung gt Tabelle gt Bearbeiten gt Dr cken Sie in der Messwerte Tabelle auf eines der Felder in Bemerkung der Spalte Bemerkung Schnellzugriff ber die Felder Anzeige 1 2 im Modus Messung Aufrufen des Dialogs Einstellungen f r die Anzeigefelder ber diesen Dialog k nnen Sie auch zwischen analoger Anzeige und Statistik umschalten Messung gt 1 Anzeige 2 Anzeige Dr cken Sie auf eines der beiden Anzeigefelder gt Analoganzeige gt Einstellungen Messung gt 1 Anzeige 2 Anzeige gt Statistik gt Einstellungen mm 70 Moisture 100 Schnellzugriff ber die Felder Anzeige 1 2 im Modus Kalibration Aufrufen des Dialogs Feuchtekalibrationstyp Dichtekalibrationstyp Kalibration gt Feuchte bzw Dichte gt Drucken Sie auf das Feld Anzeige 1 Typeneinstellungen gt Einfach bzw Experte Ka 276 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Schnellzugriffe Shortcuts Aufrufen des Dialogs Optionen Feuchte bzw Optionen Dichte Kalibration gt Feuchte gt Optionen Dr cken Sie auf das Feld Anzeige 2 Kalibration gt Dichte gt Optionen ge Comelaton RMS Values 0 no auto Schnellzugriffe im Modus Verdichtungstest Aufrufen des Dialogs Messungseinstellungen Service gt MWTest gt Drucken Sie auf das Feld Anzeige 2 Verdi
33. tigt Wenn einzelne Werte entfernt oder ge ndert werden kann das dazu f hren dass die Kurve zwischenzeitlich nicht berechnet werden kann Sie erhalten dann bei jeder Berechnung eine Fehlermeldung Mit Grenzen x aktiviert Die Grenzen der nicht linearen Zonen werden bei jeder nderung neu berechnet g deaktiviert Bei einer nderung werden die Grenzen der nicht linearen Zonen beibehalten Optimierte Manuelle Korrektur x aktiviert Gemessene Temperaturen werden ber cksichtigt 7 deaktiviert Gemessene Temperaturen werden nicht ber cksichtigt HE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz Dichte Kalibration Die schrittweise Beschreibung der Kalibration finden Sie im Abschnitt Kalibrieren Details auf Seite 172 Kalibration im Labor Die Tabelle wird zur Messung der Referenzwerte wie auch fur die Eingabe der Laborwerte aufge rufen Tabelle W hlen Sie Kalibration gt Dichte Kalibration gt Tabelle um die Tabellenansicht der Kalibration zu erhalten Diese Ansicht w hlen Sie um Referenzwerte zu messen Laborwerte einzugeben oder um die Kalibration zu bearbeiten 4H 1 Dr cken Sie auf die Betriebsartanzeige Kalibration Feuchte oder das Tabellen Symbol um zur Tabellenansicht umzuschalten Das Men hat folgende Men punkte Tabelle gt Bearbeiten Details auf Seite 235 Tabelle gt Einstellungen Details auf Seite 238 Tabelle gt
34. 10 solange durch bis Sie vom Ger t aufgefordert werden eine Bemerkung einzugeben Der Dialog zur Eingabe einer Bemerkung wird angezeigt Hier geben Sie z B die Nummer der Probe ein Dann dr cken Sie auf bernehmen Der Messwert wird angezeigt Falls der Messwert au erhalb der eingestellten Alarmgrenzen liegt wird der Balken in der Anzeige rot eingef rbt Hinweis Auch wenn f r eine Probe mehrere Messungen durchgef hrt werden wird nur eine Zeile mit dem Mittelwert der Messungen angezeigt O 7 2 1 1 2 Messwerte drucken Ist ein Drucker ber den USB Anschluss oder die Netzwerkverbindung angeschlossen k nnen wahlweise die grafische Darstellung der Messwerte oder die Tabelle ausgedruckt werden Grafik drucken Dr cken Sie Messung gt Grafik gt Drucken Sie erhalten den Standard Druckerdialog und k nnen nun wie blich die Druckeinstellungen fest legen und die Ausgabe durch Klicken auf Drucken starten Tabelle drucken Dr cken Sie Messung gt Tabelle gt Drucken Markieren Sie in der Tabelle die Werte die gedruckt werden sollen oder dr cken Sie auf Alle wenn die komplette Tabelle gedruckt werden soll Dr cken Sie auf Drucken Sie erhalten den Standard Druckerdialog und k nnen nun wie blich die Druckeinstellungen fest legen und die Ausgabe durch Klicken auf Drucken starten SHE sartorius 183 mechatronics WLM6009 a10081 LMA316PA LMA321PA Messen 184 HE sartorius mechatronics WL
35. 14 14 06 REMARK 15 7 28 5 14 26 3 16 16 2007 04 13 14 14 09 REMARK 16 7 25 511 26 3 d 17 2007 04 13 14 14 11 REMARK 17 7 24 5 11 263 18 18 2007 04 13 14 14 13 REMARK 18 21 511 26 3 19 19 2007 04 13 14 14 16 REMARK19 7 28 5 17 26 4 20 20 2007 04 13 141418 REMARK20 7 27 5 17 26 4 21 21 2007 04 13 14 14 20 REMARK 21 7 26 5 17 26 4 22 22 2007 04 13 14 14 22 REMARK22 7 22 5 08 26 4 23 23 2007 04 13 14 14 25 REMARK 23 7 30 5 12 26 3 Start p stop 8 li al EZ Dw yee Start Stop Store Goto first Page back Step bac to sten Forward Page forward Goto last measuring Save sensor value A might damage the surface HE sartorius seg D mechatronics Table or other display of measured values Navigation ATTENTION Touch the controls on the touch screen directly with your finger or specially designed pens Never use pointed objects such as screwdrivers ballpoint pens etc These 43 WLM6009 a10081 LMA316PA LMA321PA Quick guide to measuring Quick guide to measuring w DNS Start unit Turn on the unit using the On Off switch at the back The software will launch automatically the screen will turn blank while it is loading When the user interface appears on the screen the unit is ready to operate You may be asked to log on If so enter your user name and password and press Apply Recommendation Wait a couple of minutes before you start measuring after turning the unit o
36. 24 44 3 00 0 265 3 35 Anzeige 16 29 2009 03 20 12 24 46 9 03 0283 Tabelle faz 30 2009 03 20 12 24 48 am 0 226 3 33 Grafik 18 31 2009 03 20 12 24 51 8 96 0 248 3 32 i EI 32 2009 03 20 12 2453 am 0 321 332 Wertanzeige ES 33 2009 03 20 12 24 54 8 97 0 236 3 29 21 34 2009 03 20 12 24 57 9 04 0 274 3 33 Schaltfl chen Messung gt gt Pi Vor Seite vor Zum Ende Kalibration Schaltfl chen Navigation Am Ende dieses Kapitels finden Sie Erkl rungen zu den Dialogen Sprung Details auf Seite 267 Texteingabe Details auf Seite 267 Zahleneingabe Details auf Seite 268 Einstellungen f r Tabellen Details auf Seite 269 und eine Liste der Meldungen Details auf Seite 270 Hinweis f r Ger te ohne Touchscreen und bei Steuerung ber einen externen PC Falls das Ger t nicht mit einem Touchscreen ausgestattet ist und oder wenn Sie das Ger t ber einen PC steuern beachten Sie bitte Klicken Sie mit der Maus auf die Schaltfl chen e Anstelle der virtuellen Tastatur wird ein Eingabefeld angezeigt wenn eine Eingabe erforderlich ist Geben Sie dann entsprechende Zahlen oder Zeichen ber die am Messger t oder PC ange schlossene Tastatur ein 13 1 Men Dr cken Sie diese Schaltfl che um das Men anzuzeigen Sie erhalten ber das Men Zugang A zu allen Befehlen und Einstellm glichkeiten BE EE sartorius 205 e HO mec
37. Bedienung von TMV erleichtern finden Sie ab Seite 275 5 3 Messger t und PC verbinden Direkte Verbindung von Messger t und PC Voraussetzungen Auf dem Windows PC ist die Software TMV installiert siehe Seite 159 1 Verbinden Sie PC und Messger t direkt mithilfe eines Crossover Netzwerkkabels 2 Starten Sie TMV auf dem PC 3 Klicken Sie auf die Schaltfl che mit dem Haus Symbol und w hlen Sie den Befehl Systemein stell gt Konfiguration gt Kommunikation gt MW Ger te 4 Erstellen Sie einen neuen Eintrag f r ein Ger t ber den Befehl Systemeinstell gt Konfigura tion gt Kommunikation gt MW Ger te gt Bearbeiten gt Neu Wahlen Sie als Typ MW4xxx Wahlen Sie als Schnittstelle TCP IP Geben Sie die IP Adresse des Messgerats ein Die Standard Adresse ab Werk ist 172 28 1 1 O Hinweis Falls die Verbindung mit der Standard Adresse nicht m glich ist ermitteln Sie die IP Adresse direkt am Messgerat siehe Seite 164 zs As 5 Klicken Sie auf Verbinden Steuerung ber einen PC im Netzwerk 1 Verbinden Sie PC und Ger t jeweils ber Netzwerkkabel mit dem bestehenden IP Netzwerk 2 Falls nicht bereits bekannt ermitteln Sie die IP Adresse des Messger ts siehe IP Adresse des Messger ts ermitteln Details auf Seite 164 O Hinweis Bei der Einbindung in ein bestehendes Netzwerk kann nicht immer die werkseitige Standard IP Adresse verwendet werden siehe hierzu IP Adresse des Messger ts ndern Detai
38. Drucken Details auf Seite 238 Tabelle gt Export Details auf Seite 238 O Hinweis Wenn de Tabelle mehr als 10 Werte enth lt nutzen Sie die Schaltfl chen zur Navigation Details auf Seite 212 Tabelle gt Bearbeiten Werte Referenzwerte f r die vermessenen Proben werden hier in die Kalibrationstabelle eingetragen 1 Wahlen Sie im Men Kalibration gt Dichte Kalibration gt Tabelle gt Bearbeiten gt Werte W hlen Sie ob Sie einen einzelnen Eintrag Bemerkung Referenzdichte Typ oder alle Werte bearbeiten wollen Bemerkung Details auf Seite 236 Referenzdichte Details auf Seite 236 Typ Details auf Seite 236 Alle Werte Details auf Seite 237 Die Tabelle wird nun im Modus zur Bearbeitung angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen Seite 210 zum Markieren einer oder mehrerer Zeilen 1 Dr cken Sie auf eine Zeile um diese zu markieren EI 2 Dr cken Sie auf die Schaltfl che zum Bearbeiten Falls Sie die Eingabe eines einzelnen Wertes Bemerkung Referenzdichte gew hlt haben erhalten Sie den entsprechenden Dialog zur Zahleneingabe Details auf Seite 268 bzw zur Texteingabe Details auf Seite 267 Falls Sie die Eingabe f r Typ gew hlt haben erhalten Sie den Dialog Typ 2 Seite 227 Falls Sie die Eingabe f r alle Werte gew hlt haben erhalten Sie den Dialog Kalibrationseigen schaften 2 Seite 229 SHE sartorius 235 mechatronics WL
39. Durch Kopieren eines Eintrags lassen sich auf einfache Weise hnliche Eintr ge anlegen W hlen Sie im Men Bearbeiten gt Kopieren Die Tabelle wird nun im Modus zum Kopieren angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen Seite 210 zum Markieren einer oder mehrerer Zeilen Dr cken Sie auf eine Zeile Der Eintrag ist markiert Dr cken Sie auf Kopieren Markierte Zeilen werden kopiert und als neue Werte in die Tabelle eingef gt Dr cken Sie auf Schlie en Der Kopier Modus ist beendet HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz Neu 1 W hlen Sie im Men Bearbeiten gt Neu Sie erhalten den Dialog Ger teeigenschaften 2 Dr cken Sie auf ein Eingabefeld Sie erhalten den Dialog zur Zahleneingabe Details auf Seite 268 bzw zur Texteingabe Details auf Seite 267 3 Dr cken Sie auf bernehmen VG Der Eintrag f r ein neues Ger t ist angelegt Einstellungen Sie erhalten den Dialog Einstellungen Die Darstellung der Tabelle zur Anzeige der Produktein stellungen kann hier individuell angepasst werden Lesen Sie hierzu Einstellungen f r Tabellen Details auf Seite 269 Drucken Die Parameter f r ein oder mehrere Ger te k nnen ausgedruckt werden Die Tabelle wird nun im Modus zum Drucken angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen Seite 210 zum Markieren einer oder mehrerer Zeilen 1 Dr
40. Einweisungen z B f r sp ter neu eingestellte Mitarbeiter m ssen durch den Betreiber des Ger ts sichergestellt werden Das Bedienpersonal muss die Gebrauchsanleitung gelesen und verstanden haben Gefahrenhinweise GEFAHR Lebensgefahr durch elektrischen Stromschlag Das Messger t darf nicht in Wasser oder andere Fl ssigkeiten getaucht werden oder damit in Be r hrung kommen Stellen Sie keine mit Fl ssigkeit gef llten Beh ltnisse z B Kaffeetasse auf das Messger t Stromschlaggefahr Ziehen Sie den Stecker vom Messger t aus der Steckdose wenn Sie das Ger t l ngere Zeit nicht benutzen bevor Sie das Ger t reinigen bevor Sie das Ger t wegpacken oder umstellen wenn Sie eine Arbeit am Messger t durchf hren z B Ger te anschlie en oder die Sicherungen wechseln wenn w hrend des Betriebs offensichtlich eine St rung auftritt bei Gewitter Ziehen Sie dabei immer am Stecker nicht am Kabel Achtung Sachsch den Achten Sie auf einen ausreichend gro en Abstand zu starken W rmequellen wie Heizplatten Heizungsrohren u a Verwenden Sie zum Reinigen keine aggressiven chemischen Reinigungsmittel Scheuermittel harte Schw mme o a Die Oberfl che des Touchscreen ist empfindlich Ber hren Sie sie nur mit den Fingern oder speziell daf r vorgesehenen Stiften Verwenden Sie keine Kugelschreiber Schraubenzieher oder andere Gegenst nde mit scharfen Kanten Stellen Sie das LMA316PA LMA321PA auf einen stabil
41. Falls kein entsprechender Modus angezeigt wird m ssen sie einen Modus manuell an legen einlesen oder einen bestehenden Modus bearbeiten Seite 251 Das Ger t erkennt im Normalfall die von den angeschlossenen Sensoren bereitgestellten Modi Hinweis Grunds tzlich sollte zun chst ein Sensormodus mit hoher Empfindlichkeit ausgew hlt werden Nur wenn mit diesem Modus keine Messungen m glich sind sollte die Empfindlichkeit durch Auswahl anderer Sensormodi verringert werden Feuchte Dichte eo Offset Ein Offset wird angegeben wenn auf die Kalibration eines hnlichen Produkts verwiesen wird aber eine bestimmte Standardabweichung dazu vorliegt oder wenn zwischen angezeigtem Wert und tats chlichem Wert Labor konstant die gleiche Diffe renz besteht Obere Grenze Untere Grenze Sie k nnen Grenzwerte angeben Wenn diese bei einer Messung berschritten werden wird ein Alarmereignis ausgel st Speicher W hlen Sie hier wieviele Speicherpl tze f r Messwerte f r das Produkt reserviert werden sol len Die hier eingegebene Zahl entspricht Zeilen in der Tabelle der Messwerte Der Wertebereich Speicher ist abh ngig von der Anzahl der Produkte und Kalibrationen ty pisch verbleiben ca 2000 Speicherpl tze f r die Messungen e W hlen Sie die Einstellung auto wenn ein Produkt den f r Messwerte verf gbaren Speicher komplett nutzen darf HE sartorius 167 mechatronics WLM6009 a10081 LMA316PA LMA321PA Kal
42. Feld Adresse ablesen IP Adresse des Messger ts ndern Falls Sie das Messger t in ein bestehendes Netzwerk einbinden m chten muss dem Messger t eine geeignete Netzwerkadresse zugeweisen werden Im Normalfall wird die IP Adresse des Messger ts bei der Installation vom Service Techniker Ihren W nschen entsprechend ber die Service Schnittstelle eingestellt Wurde das Messger t jedoch wieder auf die Fabrikeinstellungen zur ckgesetzt 2 Seite 189 hat das Ger t wieder die Standard Adresse 172 28 1 1 und ein Zugriff ber das Netzwerk ist nicht mehr m glich In diesem Fall muss dem Messger t wieder die gew nschte Adresse ber eine Direkt Verbindung zugewiesen werden Bei Messger ten mit Touchscreen LMA321PA bzw externem Monitor und Tastatur LMA316PA kann diese nderung direkt am Messger t vorgenommen werden W hlen Sie am Messger t Systemeinstell gt Konfiguration gt Kommunikation gt Dieses TMV Geben Sie im Dialog Dieses TMV die IP Adresse ein und machen Sie ggf weitere Angaben zur Netzwerkeinbindung Informationen zu Ihrem Netzwerk erhalten Sie von Ihrem Netzwerkadmi nistrator 3 Dr cken Sie abschlie end auf bernehmen HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA 6 Kalibrieren Fur jedes Produkt dessen Feuchte oder Dichte gemessen werden soll muss jeweils einmalig eine Kalibration durchgef hrt werden Das Messverfahren ist ein indirektes Verfahren Es liefert ei
43. HP_LaserJet Delete Printer HP_LaserJet Default Printer HP_LaserJet KIA O Hinweis Das Plugin Printer Configuration steht nur in englischer Sprache zur Verf gung 2 Zum Hinzuf gen eines Druckers dr cken Sie auf Add New Printer O Hinweis Bei der Eingabe des Druckernamens d rfen keine Leerzeichen und nicht die Zeichen und verwendet werden 3 Geben Sie ber die virtuelle Tastatur einen Namen f r den Drucker ein unter dem dieser Drucker in TMV ausw hlbar sein soll und dr cken Sie auf bernehmen Der Dialog wechselt automatisch zum Register Printer Device Printer Configuration Administration Printer Device Make Model Driver Printer Options Printer Version 0 1 4 test z Hostname IP Port Queue 631 f Device URI http Device Info Set New Device URI http amp ern E 4 Unter Device werden alle im Netzwerk gefundenen Drucker angezeigt W hlen Sie den gew nschten Drucker aus und dr cken Sie auf Next sartorius 199 mechatronics WLM6009 a10081 LMA316PA LMA321PA Weitere Funktionen 200 10 Hinweis Uber die Taste Init k nnen Sie die Liste aktualisieren z B wenn der gew nschte Drucker noch nicht eingeschaltet war als Sie den Dialog Printer Configuration aufgerufen haben Die Felder im rechten Bereich des Registers m ssen Sie im Normalfall nicht bearbeiten Sie sind nur f r den Fall vorgesehen dass ein Netz
44. Hinweis In der Tabelle wird in den Spalten Feuchte Abw bzw Dichte Abw die Abweichung der Referenzwerte von den Kalibrationswerten angezeigt Sortieren Sie die Tabelle nach diesen Werten Auf diese Weise finden Sie schnell den Wert mit der gr ten Abweichung Nach erneutem Sortieren steht am Kopf der Tabelle der Wert mit der gr ten negativen Abweichung 2 Dr cken Sie auf L schen E Der markierte Wert wird gel scht x 3 Dr cken Sie auf Schlie en Der L sch Modus ist beendet Einzelne Kalibrationspunkte k nnen mit verschiedenen Symbolen dargestellt werden Auf diese Weise lassen sich z B die Werte f r Proben verschiedener Tage kennzeichnen Seite 227 Die Kalibrationskurve wird vom Ger t weitgehend automatisch bestimmt Trotzdem haben Sie die M glichkeit durch die Eingabe einiger Parameter die Kalibrationskurve genauer zu gestalten Informationen hierzu finden Sie im Abschnitt Typeneinst Details auf Seite 232 Offset Der Offset einer Kalibrationskurve kann korrigiert werden Dies bedeutet dass die gesamte Kurve parallel verschoben wird Ein Offset wird in folgenden F llen verwendet Gleichm ig auftretende Abweichungen der Kalibration sollen korrigiert werden Bei der Messung wird auf die Kalibration eines anderen Produktes referenziert Der ermittelte Feuchtigkeitswert wird an einer Stelle im Produktionsablauf ben tigt oder ange zeigt an der der Feuchtewert des Produktes bekannterweise tiefer bzw h
45. Im aufgeklappten Listenfeld dr cken Sie auf Pos Position oder Zeit Entsprechend Ihrer Wahl werden weitere Eingabefelder wahlweise f r die Positionsnummer oder f r Datum und Uhrzeit angezeigt 2 Dr cken Sie auf eines der Zahlen Eingabefelder Sie sehen nun den Dialog zur Zahleneingabe Details auf Seite 268 3 Geben Sie den gew nschten Wert ein und dr cken Sie auf bernehmen im Dialog f r die Zah leneingabe Der Wert wird nur bernommen wenn f r die gew hlte Postion bzw f r das gew hlte Datum Ein tr ge vorhanden sind 4 Nachdem Sie Ihre Auswahl getroffen haben dr cken Sie auf bernehmen im Sprung Dialog Die Tabelle zeigt jetzt den entsprechenden Eintrag In der grafischen Darstellung springt der Cursor auf den entsprechenden Eintrag In den Anzeigen werden die Werte des gew hlten Eintrags dargestellt Texteingabe Dieser Dialog wird dann angezeigt wenn Texte eingegeben werden sollen O Hinweis Ist in den Systemeinstellungen gt Globale Einstellungen gt Einstellungen 2 die Virtuelle Tastatur deaktiviert erscheint lediglich ein Eingabefeld in das die Texte direkt ber eine USB Tastatur bzw die Tastatur des externen PCs eingegeben werden 208 EECHER lwlelelrir elilolelelsl Sleisleielelslaiel e jzjxlelvjelnimls gt amp 5 EE Abbruc Schaltfl chen f r Eingaben die im jeweiligen Zusammenhang nicht sinn
46. LMA321PA Messen 7 1 10 182 Messung im Labor Hinweis Meldungen des Ger tes werden in der Statuszeile angezeigt Mehr Informationen zum Touchscreen und dessen Bedienung finden Sie im Kapitel Bedienober fl che Referenz Details auf Seite 205 Schalten Sie ggf das Ger t ein Der Schalter befindet sich an der R ckseite des Ger ts Empfehlung Warten Sie nach dem Einschalten m glichst einige Minuten bevor Sie die ersten Messungen durchf hren da das Ger t dann seine optimale Betriebstemperatur erreicht hat Hinweis Ist das Ger t bereits eingeschaltet kann u U gerade ein anderer Bereich der Software ausgew hlt sein z B Produkteinstellungen W hlen Sie in diesem Fall zuerst den Men punkt Messung Das LMA321PA startet automatisch mit dem zuletzt gemessenen Produkt Falls Sie ein anderes Produkt messen wollen m ssen Sie dieses zun chst ausw hlen falls bereits das gew nschte Produkt eingestellt ist fahren Sie fort mit Schritt 5 Dr cken Sie auf die Anzeige des Produktnamens Sie erhalten den Dialog Produktauswahl Details auf Seite 214 Markieren Sie in der Tabelle die Zeile mit dem Produkt f r das Sie Messungen durchf hren m chten Dr cken Sie bernehmen Dr cken Sie auf Start Falls sich noch ein Produkt im Sensor befindet erhalten Sie die Meldung Bitte leeren In diesem Fall entnehmen Sie das Produkt bzw setzen Sie einen leeren Messbecher ein je nach Sensor Das Ger t zeigt kurz die
47. Meldung Leerabgleich und anschlie end Bitte f llen Hinweis Falls Sie aufgefordert werden den Sensor zu leeren obwohl dieser leer ist dann dr cken Sie auf die Schaltfl che Leerabgleich und w hlen Sie Hart Dem Sensor wird so mitgeteilt dass er leer ist eventuelle Ver nderungen am Sensor z B Verschmutzung oder thermische nderung werden auf diese Weise kompensiert F r den Leerabgleich m ssen Sie sich ggf mit den entsprechenden Benutzerrechten anmelden siehe Seite 166 Bef llen Sie den Sensor Falls Sie einen Sensor mit Messbecher nutzen achten Sie darauf dass der Messbecher kom plett gef llt ist Vermeiden Sie bei der Bef llung des Messbechers das Entstehen gr erer Hohl r ume Optional F hren Sie den Temperatursensor Pt 100 in die Probe ein Hinweis Die Temperatur soll in der Regel bei Temperaturschwankungen von ber 5 C bei der Kalibration ber cksichtigt werden Die Messung wird vom Ger t durchgef hrt Bei gleichzeitiger Temperaturmessung wird die Messung dann durchgef hrt wenn ein konstan ter Temperaturwert gemessen wird Speichern Sie das Ergebnis durch Dr cken der Speichern Schaltfl che EE sartorius a eegg mechatronics 11 12 I 13 WLM6009 a10081 LMA316PA LMA321PA Messen Je nach genutztem Sensor und den Einstellungen des Systems werden Sie aufgefordert die Probe zu drehen oder eine neue Probe in den Sensor zu geben Fuhren Sie die Schritte 6 bis
48. Print The normal Print dialog pops up Change the settings as necessary then press Print Turn off unit Turn off the unit using the On Off switch at the back You do not need to exit the operating software first EE sartorius a 00 x mechatronics WLM6009 a10081 LMA316PA LMA321PA 8 Taking measurements Prerequisites The device is connected to at least one sensor page 24 You have created at least one product page 30 The machine has been calibrated to analyze the product to be measured gt page 35 Taking measurements 1 If the device is off turn it on 2 Select a product 3 Start measuring 4 Read the values Start Start measurement Stop measurement e X The measurement process differs depending on the type of application Single measurement solid product in the laboratory Following an empty sensor adjust the product is placed in or on the sensor The measurement is started The measured values moisture density temperature are displayed Multiple measurements bulk material in the laboratory Following an empty sensor adjust a measuring cup is placed in or on the sensor The measure ment is started If necessary the position of the measuring cup is changed e g by rotating it The measured values moisture density temperature are displayed A new measurement is trig gered For more information see Taking measurements in the laboratory Det
49. The measurement now takes place for the selected product Table The measurement values are displayed in a table Press the column header to sort the table The current sort order is indicated by an arrow in the column header Note The first column without title shows the row number position dependent on the sorting The No column shows the automatically allocated sequential number for the measurement value Note You can customize the appearance of the table by choosing Measurement gt Table gt Settings Details on page 76 Here you can determine whether the table can be sorted or whether the columns can be moved Use the controls described in Navigation Details on page 72 to show further values in the measurement series Press the Measurement mode display or the table symbol to switch to the graphical display To start or stop the measurement process and to take samples and carry out an empty sensor adjustment use the controls described in Measurement Calibration Details on page 70 Determining the cursor position Press a row The row is highlighted by a red border When you switch to the graphical display page 77 the cursor position is retained Note Press the Goto last control once The control remains activated and therefore has a blue background The most recently measured value is displayed in the bottom row The table is constantly refreshed HE sartorius seg mechatronics WLM6009 a10081 LM
50. USB port on the front of the device Note You may have to wait a few seconds until the USB stick is detected and thus ready for use Choose Service gt Backup The Backup dialog appears By default the Backup function is selected in the upper panel Press Apply The backup is saved to the USB stick the Backup dialog then closes automatically A name is automatically generated for the backup file from the current date and time This prevents the accidental overwriting of an old backup file when a new backup is saved Backup on external PC Choose Service gt Backup The Backup dialog appears By default the Backup function is se lected in the upper panel Press Browse A typical Windows dialog appears prompting you to navigate to the required stor age location for the backup file A name is automatically generated for the backup file from the current date and time This prevents the accidental overwriting of an old backup file when a new backup is saved You can change the file name if required Attention lf you change the name of the backup file you must observe the convention Backup _ lua If you fail to do so you will not be able to restore the backup later on Press Save The backup is saved to the PC and the Backup dialog closes automatically Restore You can use this function to restore a previously created backup state Caution When you carry out a system restore all measurements inputs and so on made since the
51. Werte einen Hoch bzw Tiefpunkt darstellt x Kurve mit Extremwert U Kurve ohne Extremwert aA HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz Korrektur W hlen Sie hier ob und wie eine Korrektur f r die Kalibrationskurve erfolgen soll Die Kalibration ber cksichtigt dann Schwankungen von Temperatur und oder Dichte der Proben in der gew hlten Form Falls nicht genug Messwerte vorliegen um eine sinnvolle Korrektur durchf hren zu k nnen erhalten Sie eine entsprechende Meldung Hinweis Die Ber cksichtigung von Temperatur und oder Dichte setzt voraus dass entspre chende Werte f r die Proben vorliegen Die Temperatur soll in der Regel bei Temperaturschwankungen von ber 5 C ber cksichtigt werden Dr cken Sie auf bernehmen um die Einstellung zu bernehmen und die Kalibration zu berech nen Nach erfolgreicher Berechnung der Kalibration werden die Parameter im Feld 1 Anzeige 2 Anzeige angezeigt Dr cken Sie auf Experte um alle Einstellungen manuell vorzunehmen Dr cken Sie auf auto um die Kalibration automatisch zu berechnen Experte Die Einstellungen f r die Kalibration k nnen hier manuell vorgenommen werden Einstellungen die Sie zuvor gemacht haben linear nichtlinear Anzahl der Segmente werden bernommen k nnen aber hier wieder ge ndert werden Die Grenzen der einzelnen Segmente der Kalibrationskurve k nnen eingeste
52. an incorrect AB offset is selected measurements are not independent of density Prerequisites You are logged in with at least level 5 user rights gt page 30 Choose Service gt MW test gt Compression test Select the product to be tested To display the dialog for choosing a product press the product name Note The currently selected product is indicated by a green tick in the No column Press the row containing the name of the product to be tested Press Apply You can now start or edit a compression test for the selected product Press the 2nd display panel and specify the properties for the measurement 2 page 33 Determine the amount of memory for measured values EE sartorius e H mechatronics WLM6009 a10081 LMA316PA LMA321PA Calibration 11 2 90 o N o Define the measurement mode For laboratory measurements deactivate the continuously option to enable the carrying out of individual measurements as described in steps 7 to 10 Perform an Empty sensor adjust Slowly fill the sensor until the header line shows a measuring value Press Start to store the value Slowly continue filling the sensor and press Start again to store the measured value Repeat this procedure until the sensor is completely full The results measured in the test are displayed in a table You can depict individual points on the plotted curve using different symbols and you can delete points from the curve if r
53. auf bernehmen Das Ger t erstellt eine Backup Datei Gespeichert werden sowohl alle im Ger t gespeicherten Daten Ger te und Produktparameter Messwerte Kalibrationen wie auch die Softwareinforma tionen Der Dateiname wird aus Datum und Uhrzeit automatisch erstellt Die Datei wird auf dem USB Stick gespeichert Dr cken Sie auf Bearbeiten wenn Sie den Dateinamen ndern wollen Nach kurzer Wartezeit kann der USB Stick entfernt werden Backup auf externen PC Dr cken Sie auf Durchsuchen und w hlen Sie den Speicherort Gegebenfalls ndern Sie den Dateinamen Beachten Sie dabei die Schreibkonvention backup_ lua Dr cken Sie auf Speichern Wiederherstellen USB Stick nur bei Laborger ten Achtung Bei Einlesen eines Backups gehen alle zwischenzeitlich auf dem Ger t gespeicherten Daten verloren Erstellen Sie vor dem Einlesen eines Backups ein aktuelles Backup Stecken Sie an der USB Schnittstelle des Ger tes den USB Stick mit der Backup Datei ein Die Backup Datei muss mit einem Ger t des gleichen Typs erstellt worden sein Dr cken Sie im Dialog Backup nach Auswahl von Wiederherstellen auf das untere Listenfeld W hlen Sie eine der angezeigten Backup Dateien Dr cken Sie auf bernehmen Es wird der Zustand des Ger tes wiederhergestellt der durch das Backup gesichert wurde Nach kurzer Wartezeit kann der USB Stick entfernt werden Wiederherstellen von externem PC Achtung Bei Einlesen eines Backups ge
54. backup was saved are lost You may wish to back up the current state of the system before running the Restore function Prerequisites The measuring device is switched on and you are logged in with level 4 access rights or higher see Creating a backup Stop any measurements that are currently in progress Insert the USB stick containing the backup files into the USB port on the front of the device omit this step if restoring a backup saved on an external PC Note You may have to wait a few seconds until the USB stick is detected and thus ready for use Choose Service gt Backup The Backup dialog appears Choose Restore from the top panel The bottom panel now displays a list of all available backup versions Select the required backup from the list and press Apply The data is loaded and the state stored in the selected backup file is restored If you want to restore a backup saved on an external PC and the backup in question does not appear in the list press Browse A typical Windows dialog appears prompting you to navigate to the storage location of the required backup Select the required backup file and press Open EE sartorius a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Service and maintenance 10 3 SO aS Restoring factory settings You use this function to restore the entire system to the state defined by the pre set internal backup Attention Restoring the factory settings deletes all m
55. beider Ger te ber das entsprechend gekennzeichnete Kabel miteinander verbinden ber das andere Kabel die mit MW Det bezeichneten Anschl sse verbin den Schlie en Sie das gr n gekennzeichnete Kabel am Anschluss MW Gen 1 des LMA321PA und am Gen Anschluss des Sensors an Schlie en Sie das zweite Mikrowellenkabel am Anschluss MW Det 1 des LMA321PA und am Det Anschluss des Sensors an Verbinden Sie die Sensor 1 Anschl sse beider Ger te mit dem mitgelieferten Datenkabel Verbinden Sie die mitgelieferte Tastatur mit dem PS2 Anschluss der mit dem Tastatur Symbol gekennzeichnet ist Verbinden Sie den Temperatursensor Pt 100 mit der mit dem Thermometer Symbol gekenn zeichneten Buchse Beachten Sie hierzu bitte die Hinweise auf Seite 156 Stellen Sie nun ggf alle weiteren optionalen Verbindungen zu anderen Ger ten wie Monitor Maus usw her siehe bersicht auf der n chsten Seite Stecken Sie das Netzkabel in das LMA316PA LMA321PA und anschlie end in eine entspre chende Netzsteckdose HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Inbetriebnahme Anschlussschema M gliche Optionen LMA316PA LMA321PA Die folgende Darstellung zeigt den Anschluss aller m glichen optionalen Komponenten Welche dieser Komponenten Teil Ihres Systems sind entnehmen Sie bitte Ihren Bestellunterlagen Eine Kurzbeschreibung aller Anschl sse des LMA316PA LMA321PA finden Sie auf Seite 150 Sensor 2 Sensor 1 S
56. cken Sie auf eine Zeile um diese zu markieren dh 2 Dr cken Sie auf die Schaltfl che Drucken Das weitere Vorgehen ist abh ngig davon ob der Drucker direkt am Messger t angeschlossen ist oder Sie von einem externen PC aus arbeiten x 3 Dr cken Sie auf Schlie en Das Drucken der Werte ist beendet Export Die Tabelle wird im Format csv exportiert und auf dem angeschlossenen USB Stick gespeichert EZ 1 Dr cken Sie auf Bearbeiten um den Dateinamen zu ndern O Hinweis Wenn Sie das Programm am PC nutzen erhalten Sie den Dialog Export Hier w hlen Sie einen Speicherort auf dem PC und hier ndern Sie gegebenenfalls den Namen der Exportdatei O Hinweis Microsoft Excel 2003 Das weit verbreitete universelle Exportformat csv ist f r Excel 2003 nicht richtig zu interpretieren Benennen Sie die csv Datei in txt um und importieren Sie sie in Excel 2003 mit der Importfunktion Dieses TMV Wenn das Ger t ber ein IP Netzwerk mit einem PC verbunden ist und ber den PC bedient wird muss dem Ger t im Netzwerk eine IP Adresse zugewiesen werden Hier legen Sie die Netzwerkeinstellungen IP Adresse etc f r das Ger t fest Die voreingestellte IP Adresse ist 172 28 1 1 Diese IP Adresse wird wiederhergestellt wenn Sie im Ger t die Fabrikeinstellungen wiederher stellen SHE sartorius 255 seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz O Hinweis W hlen Sie aus
57. den Systemeinstellungen oder Kalibrationen zu verhindern EE sartorius a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Kalibrieren 6 3 ew hr Produkt anlegen F r jedes Produkt dessen Feuchte oder Dichte gemessen werden soll m ssen entsprechende Produktparameter am Ger t eingerichtet werden Im Auslieferungszustand des LMA3xxPA PMD3xxPA sind im Normalfall lediglich Testartikel oder vorkalibrierte Artikel angelegt sowie ein nicht bearbeitbarer Artikel zur Vermessung des Referenzk rpers optional erh ltlich siehe hierzu Referenzstandard Details auf Seite 203 Voraussetzung Sie sind mit Benutzerrechten ab Stufe 4 angemeldet 2 Seite 166 W hlen Sie den Men punkt Produkteinstellungen gt Bearbeiten W hlen Sie dort den Men punkt Neu Im Dialog Produkteinstellungen Details auf Seite 244 machen Sie folgende Angaben Allgemein Nr Fur jedes Produkt vergeben Sie eine eindeutige Kennnummer Geben Sie unter Name einen Produknamen ein der eine eindeutige Zuordnung zum Produkt erm glicht sowie ggf im Feld Bemerkung einen erl uternden Text Kal Nr Wenn f r das Produkt eine nicht referenzierende Kalibration durchgef hrt wird dann w hlen Sie hier selbst Wenn auf die Kalibration eines hnlichen Produkts referenziert wird dann w hlen Sie hier die Kennnummer des Produkts Sensormodus W hlen Sie hier den Sensor und den entsprechenden Modus mit dem das Produkt gemessen wird
58. dependent manner Measuring cell See Sensor 2 sartorius 135 seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA Glossary 136 Microwave resonance procedure A moisture measurement method which is based on the measurement of two independent parameters correlated with moisture and density and on the movement of a resonance frequency and the dampening of the resonance peak It involves moving a product loaded with water into a resonance field The water acts on the field and the field changes are measured and subjected to mathematical calculations Moisture measurement technology Sartorius devices were developed to determine material moisture in solid products The microwave resonance method has particular advantages here such as speed colour and density independence precision ability to determine core moisture and independence from surface effects Packing density The measurement devices work independently of the density layer density of the product There is no need to weigh the product Planar sensor The slider shaped planar sensor is used for inline process checking with the PMD320PA PMD325PA It can be integrated into a conveyor belt hand over section a silo wall or a shaker trough The product must directly cover the sensor Sensor Hollow sensor or fork test bar for laboratory applications or planar sensor see above Surface effects The microwave resonance method works independently of the structu
59. die Messwerte nicht aber die Referenzwerte kopiert x 5 Dr cken Sie auf Schlie en Der Kopier Modus ist beendet Neu Sie erhalten den Dialog Kalibrationseigenschaften Sie erstellen unabh ngig von gemessenen Werten einen neuen Eintrag in der Kalibrationsta belle Jeder Wert kann ber diesen Dialog eingegeben werden 1 Dr cken Sie auf ein Eingabefeld und Sie erhalten den Dialog zur Zahleneingabe Details auf Seite 268 bzw zur Texteingabe Details auf Seite 267 2 Dr cken Sie auf bernehmen um den Eintrag in der Tabelle anzulegen O Beispiel Ein Wert wurde irrt mlich gel scht und muss manuell wieder eingegeben werden Werte aus anderen Kalibrationen werden zum Vergleich bernommen Tabelle gt Einstellungen Sie erhalten den Dialog Einstellungen Die Darstellung der Tabelle zur Anzeige der Kalibration kann hier individuell angepasst werden Lesen Sie hierzu Einstellungen f r Tabellen Details auf Seite 269 Tabelle gt Drucken Ausgew hlte Kalibrationswerte k nnen ausgedruckt werden Hinweise zum Anschluss eines Druckers finden Sie auf Seite 198 W hlen Sie im Men Messung gt Kalibration gt Tabelle gt Drucken Die Tabelle wird nun im Modus zum Drucken angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen gt Seite 210 zum Markieren einer oder mehrerer Zeilen 1 Dr cken Sie auf eine Zeile um diese zu markieren O Hinweis Sie k nnen mehrere Zeilen markieren 2 Dr cken Sie a
60. die an unterschiedlichen Tagen gemacht wurden verdeutlichen Dr cken Sie auf ein Eingabefeld und Sie erhalten den Dialog Typ W hlen Sie ob der Kalibrationspunkt f r die Kalibration verwendet wird g ltig x Kalibrationspunkt ist g ltig und wird f r die Berechnung der Kalibrationskurve verwen det Der Wert wird f r die Kalibration nicht ber cksichtigt Der Eintrag in der Tabelle bleibt jedoch bestehen und kann gegebenenfalls sp ter wieder auf g ltig gesetzt werden Symbol Dr cken Sie auf das Listenfeld und w hlen Sie eines der Symbole aus Der Kalibrationspunkt wird in der Grafik der Kalibration durch das gew hlte Symbol dargestellt Dr cken Sie auf bernehmen um die Einstellung zu bernehmen HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz Alle Werte Sie erhalten den Dialog Kalibrationseigenschaften Bereits bestehende Angaben werden angezeigt Dr cken Sie auf ein Eingabefeld Sie erhalten entsprechenden Dialog zur Zahleneingabe Details auf Seite 268 bzw zur Texteingabe Details auf Seite 267 Falls Sie die Eingabe f r Typ gew hlt haben erhalten Sie den Dialog Typ gt Seite 227 Dr cken Sie auf bernehmen um die Einstellung zu bernehmen L schen Einzelne Werte k nnen aus der Kalibration gel scht werden W hlen Sie im Men Kalibration gt Dichte Kalibration gt Tabelle gt Bearbeiten gt L schen Die Tabelle wird nun im Mo
61. durchsetzt Packungsdichte Die Messger te arbeiten unabh ngig von der Dichte und der Schichtdicke des Produkts Ein zus tzliches Wiegen des Produktes ist nicht erforderlich Planarsensor Der scheibenf rmige Planarsensor kommt bei der inline Prozesskontrolle mit dem PMD320PA PMD325PA zum Einsatz Er kann in einer Band bergabestelle einer Silowand oder in einer R ttelrinne integriert werden Direkte Produktbedeckung ist erforderlich Sensor Hohlraum oder Gabelsensor f r Laboranwendungen oder Planarsensor s 0 HE sartorius seg mechatronics WLM6009 a10081 A Alan ae et ee anne een 223 Anmelden een 166 Anschluss COMI get EE EE 150 Ethernet 424 2 28 eave ae 150 Maus NNN ea 151 Monitor 150 MW Dei 150 154 MW Gen 150 154 Ge 163 Sensor1 2 2 2 on nennen 150 Service Schnittstelle 150 Tastat r acarieni pane a E a nA 154 Temperatursensor 150 154 USB ante ee ee ae 151 Ansicht Grafik ur erraten 218 Profile 269 Tabelle 0 cee eee 214 NN EE aadi a rare he Aaa at 221 Anzeige EE 205 Balken 219 kontinuierliche 212 Offset Feuchte 209 Statistik er use ea area 224 Anzeige TI 222 B Balkenanzeige 224004s4444440neen nennen 219 beenden PC Programm 266 Bemerkung een 211 Benutzer anlegen ENEE AH Ha 195 bearbeiten 258 l schen wack ian a eal Sera ana een 196 HE eae aa ee rn e A 258 Rechte u doe oe AE ee 166 EN
62. einen externen PC gesteuert werden muss kein Drucker angelegt werden Hier k nnen alle auf dem externen PC zur Verf gung stehenden Drucker wie unter Windows blich genutzt werden O Hinweis Das Plugin Printer Configuration ist nur in englischer Sprache verf gbar Add New Printer Hiermit starten Sie das Anlegen eines neuen Druckers Sie werden aufgefordert einen Namen f r den neuen Drucker einzugeben Unter diesem Namen wird der Drucker nach dem Anlegen in TMV angezeigt Nach Dr cken auf bernehmen wechseln Sie automatisch zum Register Printer Device wo Sie den gew nschten Drucker ausw hlen In der Liste im Feld Device werden alle Drucker angezeigt die entweder ber USB Kabel direkt am Messger t angeschlossen und eingeschaltet oder ber das IP Netzwerk verf gbar sind ber die Funktion Init kann erneut nach angeschlossenen Druckern gesucht werden wenn beispielsweise ein Drucker erst nach dem Aufrufen des Dialogs eingeschaltet wurde Nach Dr cken auf Next wechseln Sie zum Register Make Model Driver wo Sie Druckerher steller und modell pr fen und ggf ndern Anschlie end dr cken Sie auf Add Printer um den neuen Drucker der Liste der TMV Drucker hinzuzuf gen Set As Default Der in der Liste ausgew hlte Drucker wird als Standarddrucker bestimmt Ist kein Standarddru cker festgelegt wird der erste Drucker in der Liste als Standard verwendet Printer Options Auf diesem Register werden druckerspezifische Vo
63. for creating a new user is displayed D page 116 Edit The dialog for changing the settings of the previously selected user is displayed page 116 Delete The selected user is deleted Note You must retain at least one user with level 5 access rights You cannot delete the current default user Apply All changes are saved The user configuration dialog closes Cancel The user configuration process is terminated without saving the changes User settings User name This name is entered by the user when he or she logs on using the login screen Last name First name These entries assign the user name to a real person Password input Enter the password which the user has to enter when logging on Repeat password Enter the password again to exclude the possibility of typing errors User level Select one of the available levels There are six different user levels The rights assigned to any one level include the rights of all lower levels The lowest level 0 only enables measuring whilst the highest level 5 provides access to all settings Menu items for which a user does not have authorization are not displayed to the user in question Certain users may not be able to edit specific values in dialogs but the set values are still displayed for informational purposes EE sartorius a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference S amp HE sartorius
64. hlen Sie Service gt Backup Es ffnet sich der Dialog Backup W hlen Sie im oberen Feld die Funktion Fabrikeinstellungen wiederherstellen Dr cken Sie bernehmen Der im internen Backup gespeicherte Zustand wird wieder herge stellt HE sartorius 189 mechatronics WLM6009 a10081 LMA316PA LMA321PA Wartung und Pflege 9 3 Sicherungen auswechseln GEFAHR Lebensgefahr durch elektrischen Stromschlag AN Vor dem Kontrollieren und Auswechseln der Sicherungen Ger t ausschalten und vom Netz tren nen 1 Schalten Sie das LMA321PA ber den Ein Ausschalter 1 auf der R ckseite aus und ziehen Sie das Netzkabel ab 2 Ziehen Sie den Einschub 4 zwischen Netzanschluss und Ein Ausschalter heraus 3 Pr fen Sie beide Sicherungen 2 3 und ersetzen Sie diese ggf durch den technischen Daten entsprechende Sicherungen Seite 192 4 Schieben Sie den Einschub mit den Sicherungen ein bis er einrastet Anschlie end kann das Ger t wieder mit dem Stromnetz verbunden und eingeschaltet werden 190 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Wartung und Pflege 9 4 Reinigung GEFAHR Lebensgefahr durch elektrischen Stromschlag AN Schalten Sie das Ger t vor dem Reinigen aus und ziehen Sie den Netzstecker Das Ger t darf nicht in Wasser oder andere Fl ssigkeiten getaucht werden Verwenden Sie zum Reinigen keine aggressiven chemischen Reinigungsmittel Scheuermittel harte Schw mme o a b
65. hlten Einstellungen automa tisch zu berechnen Experte Die Einstellungen f r die Kalibration k nnen hier manuell vorgenommen werden Einstellungen die Sie zuvor gemacht haben linear nichtlinear Anzahl der Segmente werden bernommen k nnen aber hier wieder ge ndert werden Die Grenzen der einzelnen Segmente der Kalibrationskurve k nnen eingestellt werden Die Korrektur kann manuell angepasst werden Wird diese Option f r Temperatur bzw Feuchte aktiviert so haben Sie auch in der grafischen Darstellung der Kalibrationskurve die M glichkeit die Korrektur mittels Schieberegler oder Zahleneingabe vorzunehmen Ergebnisse Auf der rechten Seite des Dialoges werden die aus den von ihnen gemachten Einstellungen resultierenden Ergebnisse angezeigt Diese Felder k nnen nicht editiert werden Falls die Kalibration sich mit diesen Parametern nicht berechnen l sst wird ein Hinweis im unteren Teil des Feldes Ergebnisse rot angezeigt Dr cken Sie auf Kalibrationen um sich eine Auflistung aller m glichen Kalibrationen anzeigen zu lassen Die Auflistung wird in demselben Dialog auf der zweiten Registerkarte Kalibrationen angezeigt Die Auflistung der Kalibrationen kann zum Zweck der bersichtlichkeit gefiltert werden Dr cken Sie dazu auf das Listenfeld Alle Kalibrationen und w hlen Sie einen Filter aus Dr cken Sie auf einen Eintrag um diesen zu markieren Dr cken Sie auf Auswahl um diese Parameter f r die Kalibration zu
66. item Table Measured values are shown in a table You can sort the table by any of its columns Columns can be individually sorted or hidden See section Table Details on page 74 e Graph Measured values are shown as a curve Tendencies or deviations can therefore be easily recog nized In addition the value range where moisture or density values seem to be critical can be depicted and an alarm can be generated accordingly See section Graph Details on page 77 Regardless of the selected type of display the navigation controls help you to find and select values See section Navigation Details on page 72 Reading The measured value is displayed in large numbers The value can be seen clearly even if the user is not working right next to the device Navigation is not possible in this case Calibration mode A table of calibration values is displayed on the screen Values can be entered added edited and deleted here The calibration graph illustrates the calibration curve but allows no direct editing of the values Status line MDevice Start This shows The status of the device or sensor e g Sensor empty or Measuring device stop A prompt e g Please Fill if user activity is required Error messages Details on page 128 The currently measured value during a measurement run EE sartorius or mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 1 If
67. k nnen ge ndert werden Das Men hat folgende Men punkte Werte Details auf Seite 244 L schen Details auf Seite 245 Kopieren Details auf Seite 245 Neu Details auf Seite 245 W hlen Sie im Men Produkteinstellungen gt Bearbeiten Die Tabelle wird nun im Modus zur Bearbeitung angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen gt Seite 210 zum Markieren einer oder mehrerer Zeilen Gesch tzte Produkte sind mit einem Schloss gekennzeichnet Bei einem gesch tzten Produkt kann die Kalibration nicht ge ndert werden Werte W hlen Sie im Men Produkteinstellungen gt Bearbeiten gt Werte Dr cken Sie auf eine Zeile um diese zu markieren Hinweis Sie k nnen mehrere Produkte markieren und gleichzeitig bearbeiten Dies ist zum Beispiel hilfreich wenn mehrere Produkte auf eine gemeinsame Kalibration verweisen oder von mehreren Produkten derselbe Sensormodus genutzt wird In diesem Fall wird mehrere in der Kopfzeile des Dialoges Produkteigenschaften angezeigt Dr cken Sie auf die Schaltfl che zum Bearbeiten Sie erhalten den Dialog Produkteigenschaften Dr cken Sie auf ein Eingabefeld Sie erhalten den Dialog zur Zahleneingabe Details auf Seite 268 bzw zur Texteingabe Details auf Seite 267 Die Produkteigenschaften werden im Abschnitt Produkteinstellungen gt Neu Details auf Seite 245 erkl rt Hinweis Falls Sie eine neue Kennnummer vergeben so werden die gew hlten Produkte mit
68. list Press Set As Default lt Name gt In doing so the selected printer is defined as the default printer for output on this measuring instrument HE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Other functions Change default settings 1 When you set up the printer if you want to change the default settings such as paper format resolution and so on select the printer whose settings you want to edit under Printer in the list 2 Press Set Printer Options lt Name gt The system displays the Printer Options tab Printer Configuration Printer Version 0 1 4 HP_LaserJet PageSize AA InputSlot Default P Resolution 300dpi e Duplex None e Option1 False Set Printer Options HP_LaserJet l x Back Next Close Heip or 3 Implement the required changes Settings that were changed but not yet implemented are dis played in red 4 Press Set Printer Options to transfer the changed settings 9 4 Reference standard This function is designed to check the technical functionality of the sensor and measuring device You may purchase a reference solid for your sensor if you wish This reference solid matches the respective sensor and must only be used for the sensor for which it was delivered The refer ence solid comes with a certificate listing the values of the solid Reference standard using TMV 1 Stop the current process to make sure that
69. mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz 222 1 Anzeige 2 Anzeige Rechts oben stehen zwei Felder zur analogen Anzeige von Messwerten oder wahlweise zur Anzeige einer Statistik zur Verfugung Die Anzeige in diesen Feldern kann unabhangig von der Wahl fur die Hauptanzeige eingestellt werden Beispiel Die Grafik zeigt die Werte f r die Feuchte In der analogen Anzeige werden Temperatur und Dichte angezeigt Beispiel Die Grafik zeigt die Messwerte am Cursor an einer Stelle der Messkurve w hrend die analoge Anzeige die aktuellen Werte darstellt Hinweis W hrend einer Kalibrierung werden hier Informationen zur laufenden Kalibrierung angezeigt F r jedes dieser beiden Anzeigefelder k nnen Sie alternativ auch die Anzeige einer Statistik w h len Dr cken Sie im Men auf Analoganzeige Details auf Seite 222 oder auf Statistik Details auf Seite 224 um die Art der Anzeige zu w hlen Den Dialog zur Einstellung erhalten Sie ebenfalls wenn Sie auf eines der Anzeigefelder dr cken Jede dieser Anzeigearten kann angepasst werden Analoganzeige Die Anzeige erfolgt in Form einer analogen Balkengrafik Online zu ag 7 00 Feuchte 10 00 Oberhalb des Balkens wird angezeigt ob der dargestellte Wert der aktuell gemessene Online oder der Wert der momentanen Cursorposition Cursor ist Falls die laufende Messung gestoppt ist wird im Falle der Online Darstellung das Anzeig
70. neuen eindeutigen Kennnummern versehen die ausgehend von der eingegebenen Nummer automatisch weitergez hlt werden Dr cken Sie auf bernehmen um die ge nderten Werte zu bernehmen HE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz x Set wi Dr cken Sie auf Schlie en Das Bearbeiten der Werte ist beendet L schen Ein Produkt kann aus der Liste gel scht werden Dies gilt nicht f r die bereits im Auslieferungs zustand vordefinierten Referenzen W hlen Sie im Men Produkteinstellungen gt Bearbeiten gt L schen Die Tabelle wird nun im Modus zum L schen angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen gt Seite 210 zum Markieren einer oder mehrerer Zeilen Dr cken Sie auf eine Zeile Das Produkt ist markiert Dr cken Sie auf L schen Das Produkt wird gel scht Dr cken Sie auf Schlie en Der L sch Modus ist beendet Kopieren Ein Produkteintrag kann kopiert werden Kopierte Eintr ge werden am Ende der Tabelle einge f gt Durch Kopieren eines Produktes lassen sich auf einfache Weise Eintr ge f r hnliche Produkte anlegen W hlen Sie im Men Produkteinstellungen gt Bearbeiten gt Kopieren Die Tabelle wird nun im Modus zum Kopieren angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen Seite 210 zum Markieren einer oder mehrerer Zeilen Dr cken Sie auf eine Zeile Der Wert ist markiert Dr c
71. samples should cover the entire moisture range for which measurements will be taken later It is an advantage if the moisture value of some samples is outside the later measuring range Make sure the samples are equally moist at all points Possible calibration mistakes The moisture range and ambient conditions for the calibration must be the same as the conditions for the subsequent measurement process The temperature of the samples during the calibration should be as similar as possible to their temperature during the subsequent measurement process Temperature compensation is not required if temperatures differ by no more than 5 C In the case of deviations greater than 5 C the temperature must be measured and taken into account Make sure that there is no water condensation on the sensor If necessary wipe the sensor with a dry cloth When working with a measuring beaker make sure that the beaker is not moist on the outside Do not work with wet hands Always entirely fill the sensor or measuring beaker Information on determining reference values Calibration measurements using the LMA3xxPA PMD3xxPA must be carried out with exactly the same samples as were used for determining the reference moisture by means of a direct lab oratory method The material moisture of the samples must not change between the calibration measurement and the determination of the moisture values in the laboratory i e the comparative measurem
72. seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Kalibrieren Ir m Kalibration drucken Ist ein Drucker direkt ber den USB Anschluss oder die Netzwerkverbindung angeschlossen k nnen wahlweise die grafische Darstellung oder die Kalibrationstabelle ausgedruckt werden Grafik drucken Dr cken Sie Kalibration gt Feuchte Dichte Kalibration gt Grafik gt Drucken Sie erhalten den Standard Druckerdialog und k nnen nun wie blich die Druckeinstellungen fest legen und die Ausgabe durch Klicken auf Drucken starten Tabelle drucken Dr cken Sie Kalibration gt Feuchte Dichte Kalibration gt Tabelle gt Drucken Markieren Sie in der Tabelle die Werte die gedruckt werden sollen oder dr cken Sie auf Alle wenn die komplette Tabelle gedruckt werden soll Dr cken Sie auf Drucken Sie erhalten den Standard Druckerdialog und k nnen nun wie blich die Druckeinstellungen fest legen und die Ausgabe durch Klicken auf Drucken starten SHE sartorius 179 mechatronics WLM6009 a10081 LMA316PA LMA321PA Kalibrieren 180 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA 7 Messen Voraussetzungen Das Ger t ist mit mindestens einem Sensor verbunden Seite 154 Mindestens ein Produkt ist angelegt Seite 167 F r das zu messende Produkt wurde eine Kalibration durchgef hrt Seite 172 Messen 1 Schalten Sie das Ger t ggf ein 2 W hlen Sie ein Produkt 3 Starte
73. settings 103 5 Startup 23 13 7 System settings 107 13 8 Service 119 5 1 Instructions for setting up the system 23 13 9 Change user 123 5 2 Connecting the instrument 24 13 10 Languages 123 5 3 Workflow overview 26 13 11 Other dialogs 123 5 4 Starting the LMA321PA 26 13 12 Messages 127 5 5 Turning the LMA321PA off 26 5 6 Information about using the software 27 14 Shortcuts 131 6 Calibration 29 45 Glossary 135 6 1 What must be taken into account when calibrating 29 6 2 Logging in to carry out calibration or create products 30 6 3 Creating a product 30 6 4 Compression test 32 6 5 Calibration 35 7 Quick guide to measuring 43 8 Taking measurements 45 8 1 Taking measurements in the laboratory 46 8 2 Printing measured values 47 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Table of contents S HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA 1 Before you begin 1 1 Overview of the documentation This documentation describes the operation of the evaluation device for microwave measuring devices The device can be operated with several sensors Basically the system may be used in laboratory operation LMA321PA and LMA316PA individual or multiple measurements as well as in production PMD320PA and PMD325PA online measurement continuously or bypass The user interface of the TMV software is almost identical for the laboratory and online measuring devices This documentation descri
74. siehe Seite 164 SHE sartorius 161 tee mechatronics WLM6009 a10081 LMA316PA LMA321PA Steuerung Uber externen PC 162 Um die Software spater zu starten doppelklicken Sie auf Ihrem Desktop auf das Icon TMV oder w hlen Sie den Men befehl Start gt Programme gt TMV gt TMV oder wahlen Sie TMV aus der Schnellstartleiste Fi TMV EL Ist das Messger t noch nicht angeschlossen erhalten Sie entsprechende Fehlermeldungen Hinweis Die Funktionen des Programms werden im Kapitel Bedienoberfl che Referenz ab Seite 205 beschrieben Hinweise zu Software Updates Wenn auf Ihrem PC bereits eine fr here Version von TMV installiert ist entf llt die Sprachaus wahl Schritt 3 und das Installationsprogramm wird automatisch in der Sprache der letzten Instal lation gestartet W hlen Sie w hrend der Installation kein anderes Verzeichnis aus Schritt 5 wird automatisch die letzte Installation mit den neuen Daten berschrieben Die Verkn pfungen beziehen sich in jedem Fall auf die zuletzt installierte Version Einstellungen der fr heren Version bleiben in diesem Fall normalerweise erhalten Falls wider Erwarten nach dem Starten von TMV keine Verbindung zum Messger t hergestellt werden kann pr fen Sie bitte die Einstellungen f r die IP Adresse Deinstallation der Software Wenn Sie TMV wieder von diesem PC entfernen m chten k nnen Sie auch das zu TMV geh rende Deinstallationsprogramm nutzen W hlen Sie Start
75. the USB port of the measuring device O Note To configure printers you must be logged on with level 4 access rights at the very least To set up a printer you choose System settings gt Configuration gt Printer Config page 115 Notes about printing directly from the measuring instrument The measuring instrument works with the printing system CUPS that is used in LINUX When you print data TMV displays a print dialog that is similar to the normal print dialog on your PC However the dialog differs in appearance depending on the selected printer Sartorius delivers printer drivers for various standard printers If no suitable driver is available for your printer you must contact Sartorius Setting up a network printer Prerequisites You are logged on and own level 4 or 5 access rights The printer is set up in the network The measuring instrument is connected to the IP network 1 Select System settings gt Configuration gt Printer config The Printer Configuration dialog is displayed Printer Configuration Administration Printer Device Make Model Driver Printer Options Printer May contain any printable characters except and space Version 0 1 4 HP_LaserJet Kb HP LaserJet Series PCL4 5 CUPS v1 2 Add New Printer Modify Printer HP_LaserJet Set Printer Options HP_LaserJet Set As Default HP_LaserJet Print Test Page HP_LaserJet Delete Printer HP_Las
76. the selection for the main screen Example The graphic shows the values for moisture Temperature and density are shown in the analog display Example The graphic shows the measured values at the cursor at a point on the measurement curve whereas the analog display shows the current values Note During a calibration run information on the current calibration is displayed here If you wish you can display statistical values in both of these display panels Press Analogue display Details on page 81 or Statistics Details on page 83 in the menu to select the type of display You can also reach the settings dialog by pressing one of the display panels Each display type can be modified if required Analogue display Values are shown as an analog bar chart Cursor 710 7 00 Moisture 10 00 Above the bar the system tells you whether the given value is the current online measurement or the value at the set cursor position cursor If the current measurement run is stopped and the set display type is Online the display panel is set to inactive greyed out Note The cursor position can be changed in the table or graph or by using the controls described in Navigation Details on page 72 The displayed value range is indicated by black marks on each side and the specification of the value The measured value is shown digitally in the middle of the bar chart The display is shown in set colours Moi
77. to edit certain values in dialogs although the set values are displayed for information purposes Access profiles and applicable user rights 0 Measurements can be performed Analysis results cannot be deleted Analysis results can be cleared Readings can be taken as a basis for calibration Calibrations can be edited kh OND Except for user administration details all system settings can be changed including sen sor modes and printer setup for example Backup copies can be made and loaded 5 Service level encompassing all access rights Users at this level can create new user records and change the access profiles of existing ones Compression test or enhancements if installed are available The system needs at least one level 5 user Service This role is already defined in the factory You will be provided with the applicable user name and password sepa rately HE sartorius cece x mechatronics WLM6009 a10081 LMA316PA LMA321PA Other functions Er S 9 2 50 Adding a new user Prerequisite You own level 5 access rights Service Open the menu and choose System settings gt Configuration gt User Config gt page 115 Select New from the User configuration Input the following details to the User new dialog User name Name that the new user must enter to log on Last name First name Details needed to more easily identify a user in the user administra tion database Pass
78. using a device with a touchscreen press the screen to go to the Measurement view at any time O Note Users who are only carrying out measurement tasks simply follow the instructions shown here O Note Some devices which are used for process measurement only have a display screen which either shows the measured values or if appropriate an error code Display panel 1 2 Measurement Two display panels are available here Each of the two displays can be set individually Cursor SS 3 00 Density 6 00 The display screen shows one of the following items The currently measured value value at the cursor position for moisture density or temperature OR The statistics for selected measurement values or all measured values 1 Press one of the display panels to change the settings for the display See section Analogue dis play Details on page 81 Select Measurements gt 1st 2nd display from the menu to change the type of the display Display panel 1 2 Calibration During calibration the display panels show information on the calibration Calibration calc Correlation 0 995 Type linear RMS 1 680 Corrections 0 Values S Type The calibration type is displayed here linear or non linear and subdivided into segments where appropriate Values This shows the following The number of calibration points Whether the calibration is computed automatically and whether the segment limits ar
79. want to start and save each measurement manually laboratory measurement devices overwriting Activate this option to overwrite old measured values once the memory capacity reserved for the test is exceeded Memory Specify the amount of memory to be reserved for the test here Current type Determine the way the measured values are depicted in the graph here Information Program version The version number of the currently installed software is shown here Backup Restore Depending on the device and system configuration backups can be saved to a connected USB stick or an external PC In the Backup dialog press the upper list box and choose Backup 2 page 121 Restore gt page 122 or Restore factory settings page 123 Backup on USB stick only for laboratory devices Prerequisites Before using this function insert a USB stick into the USB port at the front of the device Sufficient memory must be available on the USB stick 2 1 Press Apply sartorius 121 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference EI Browse 122 The device creates a backup file All data stored on the device device and product settings measured values calibrations and the software information are saved The file name is gener ated automatically from the date and time The file is saved to the USB stick Press Edit to change the file name Wait a moment before you remove
80. when saving restoring backup copies you are presented with the dialog for specifying the saving location Exports may be saved to any storage location accessible from the network In many cases you can profit from the Windows functionality Dialogs can be moved The size of the program window can be adapted The Windows clipboard copy and paste functions is active Many functions can be activated by double clicking The Print command activates the PC print dialog Printing is done by a printer connected to the PC or a network printer Exit the program by selecting Service gt Close Note An overview of the shortcuts that facilitate the operation of TMV is provided from page 131 Linking up measuring device and PC Direct connection of measuring device and PC Prerequisites The Windows PC has the TMV software installed see page 17 Use a crossover network cable to connect the PC and the measuring device Start TMV on the PC Click on the button with the house icon and choose System Settings gt Configuration gt Com munication gt MW Devices Create a new device entry by choosing System Settings gt Configuration gt Communication gt MW Devices gt Edit gt New Choose MWAxxx as the type Choose TCP IP as the interface Enter the IP address of the measuring device The default address ex works reads 172 28 1 1 Note If it is not possible to connect via the standard address determine the IP address dire
81. wird nur eine Zeile mit dem Mittelwert der Messungen angezeigt M glichkeit 2 Die Referenzwerte liegen noch nicht vor Lassen Sie das Eingabefeld im Dialog Referenzfeuchte bzw Referenzdichte leer und dr cken Sie Abbruch Der Messwert wird ohne Referenzwerte in der Tabelle angezeigt Senden Sie die Proben f r die Sie Kalibrationswerte gemessen haben zur Bestimmung der Referenzfeuchte bzw Referenzdichte an ihr Labor Hinweis Die Genauigkeit der Kalibration und damit die Genauigkeit aller sp teren Messungen h ngt von der Genauigkeit der Referenzwerte ab W hrend des Transportes und der Vermessung im Labor darf sich die Feuchte der Proben nicht ndern Beachten Sie die Hinweise zur Kalibration ab Seite 165 Nachdem Sie die Referenzwerte f r die vermessenen Proben erhalten haben werden diese Werte in die Kalibrationstabelle eingetragen W hlen Sie im Men Kalibration gt Feuchte bzw Dichte Kalibration gt Tabelle gt Bearbeiten gt Werte Im Untermen w hlen Sie den Eintrag Referenzfeuchte bzw Referenzdichte Hinweis Alternativ k nnen Sie den Eintrag Alle Werte w hlen Sie erhalten dann nach dem Dr cken der Bearbeiten Schaltfl che siehe unten den Dialog Kalibrationseigenschaften in dem Sie alle Werte dieser Kalibration bearbeiten k nnen Die Tabelle wird nun im Modus zur Bearbeitung angezeigt Dr cken Sie auf die Zeile um diese zu markieren Dr cken Sie auf die Schaltfl che zum Bearbeiten Sie e
82. 0081 LMA316PA LMA321PA Kalibrieren 6 4 Verdichtungs Test Dieser Test muss vor jeder Kalibrierung von Produkten durchgef hrt werden die sich mehr oder weniger stark komprimieren lassen F r Produkte mit konstanter Dichte z B Plattenst cke ist der Test nicht zwingend erforderlich wird aber dennoch empfohlen So k nnen Sie sich ein Bild von den Rohwerten von Frequenz und Breiten nderung machen um damit grenzwertige Messungen von vornherein zu erkennen und auszuschlie en Komprimierbare Produkte werden zun chst locker in den Sensor gef llt und dann durch Sch t teln oder Stampfen immer weiter verdichtet Jeder Verdichtungszustand wird einzeln abgespei chert Die sich aus den Punkten verschiedener Dichte gleicher Feuchte ergebende Regressionsgerade schneidet das AB Diagramm idealerweise im Ursprung Tut sie dies nicht muss der sich ergebende AB Offset f r die folgende Kalibrierung ber cksichtigt werden Ist der AB Offset falsch gew hlt ist die Messung nicht Dichte unabh ngig Voraussetzungen Sie sind mit Benutzerrechten ab Stufe 5 angemeldet Seite 166 1 W hlen Sie Service gt MW test gt Verdichtungs Test 2 W hlen Sie das Produkt f r das der Test durchgef hrt wird Den Dialog zur Produktauswahl erhalten Sie indem Sie auf den Produktnamen dr cken O Hinweis Das aktuell gew hlte Produkt ist in der Spalte Nr mit einem gr nen H kchen markiert 3 Dr cken Sie auf die Zeile mit dem Namen des Produkte
83. 009 a10081 LMA316PA LMA321PA Kalibrieren x 1 2 N Verdichtungstest Eigenschaften Auf dem Register Bereiche bestimmen Sie die Parameter f r die Messbereiche in denen Mess werte gewonnen werden in der Grafik gr n dargestellt sowie f r den Messbereich der den Leerzustand des Sensors beschreibt in der Grafik rot dargestellt Auf dem Register Scale Graph Type Regression bestimmen Sie die Parameter um die Dar stellung der Grafik anzupassen W hlen Sie f r Regression die Option Frei und dr cken Sie auf bernehmen Durch die Mes spunkte wird eine Linie gelegt 5 3 33 Verdichtungs Test Type AIB Hilfe Zur ck Current Type BH 1 Measure single Were 12 12 10 Feuchte 9 19 Dichte 4 19 26 8C Ka A are Regression Tree 5 TEST GG 9 000 Sensor Mode P145 110 A e m O 20028 1 2000 0 8000 0 4000 0 0000 0 1000 0 9000 1 9000 2 9000 3 9000 4 9000 e ge ix lt Leerabgleich Zum Anfang Seite zurich Die ermittelten Werte sollten m glichst auf einer Geraden liegen die durch den Nullpunkt geht Wenn dies nicht erreicht werden kann wenden Sie sich bitte zur Unterst tzung an den Service von Sartorius 4 2 gt gt Wenn die Ergebnisse zufriedenstellend sind dr cken Sie auf die Schaltfl che bertragen an Sensor Modus EN jet to Sensor Made Der gew hlte Sensormodus wird den Testergebnissen angep
84. 07 Default user cseeseseeeesnnnnnnnnnnnnnnnnnnnnn 117 Density correction 2220r 444440ns nennen 90 HE sartorius mechatronics LMA316PA LMA321PA Index Display Baltes er nen 77 continuing 2 222er nn 72 Offset moisture 69 Statistics 0 02 20020002 83 Display panel u nen 65 E Empty sensor adjustment s 70 Exit PC program 123 Expert Calibration een 92 101 Extremum unsere 91 100 F Factory settings 22444uun44244HHR nn nnnnnnnnnnnnnn nn 61 F SES arais eer Geessen ge 61 G Global settings nennen nnnnnnnn nn 108 Graph rn renden 77 ZOOMIN u een ernennen 77 H Hard adjustment nennen 70 History aan 73 Initialization au een 109 IP address nennen 114 Default 20 determining 21 J 0 00 0 re 72 K Keyboard Connection e 14 24 NAPCU Al a ea ee 108 L Languages 2224unnssnnnnnnnennnnnnnennnnn nenn 123 Library Sensor modes 2 222 2ee een 111 Login u 30 M Measurement Laboratory 45 Measurement method ceeeeeeeeeentteeeeeeenees 35 137 WLM6009 a10081 Measurement values Graphi eden wie ad eae ae 77 Large display 80 Table 22202 dere pees 74 Memory uusssneeeensnnnnnnnennnnnnnnennnnnnnnnen ernennen 31 Un NEEN 65 BACK ee en EE 66 Numerical sequence 66 Mode EE 69 Moisture correction cceccceceeeseeeeeeeeeneeeeeeeeeees 99 Moisture offset
85. 081 LMA316PA LMA321PA Operator Interface Reference Restoring factory settings Attention The restore process resets the device to a predefined state All measurements cali brations and settings for sensor modes or products are lost If necessary make a backup of your current settings first If the device is connected to an external PC via a network you may have to change the IP address since restoring the factory settings also resets the IP address to the address set at the factory 1 Press the upper list box in the Backup dialog Choose Restore factory settings 2 Press Apply Reset The program is closed and the user interface is restarted Close If using the program on your computer select Service gt Close to close it 13 9 Change user 1 Enter your user name and password on the Login screen 2 Press an input field The Text input Details on page 124 dialog appears 3 Press Apply 2 This logs you into the system Depending on your access rights some menu items may be invis ible or inactive greyed out 13 10 Languages You select the language for the display here 1 Press the menu item for the required language The language is changed immediately 13 11 Other dialogs These dialogs are displayed in various different contexts Jump Details on page 124 Text input Details on page 124 Numerical input Details on page 125 Settings for tables Details on page 126 RE sartori
86. 244 248 262 266 266 266 270 275 279 139 WLM6009 a10081 LMA316PA LMA321PA Inhaltsverzeichnis 140 SEE sartorius H n mechatronics WLM6009 a10081 LMA316PA LMA321PA 1 Bevor Sie beginnen 1 1 1 2 1 3 bersicht ber die Dokumentation Diese Dokumentation beschreibt die Bedienung der Auswerteeinheit f r Mikrowellen Messge r te Das Ger t kann mit verschiedenen Sensoren betrieben werden Grunds tzlich kann das System im Laborbetrieb LMA321PA und LMA316PA Einzelmessung bzw Mehrfachmessung wie auch im Produktionsbetrieb PMD320PA und PMD325PA Prozessmessung kontinuierlich oder Bypass eingesetzt werden Die Bedienoberfl che der Software TMV ist f r die Labor und Prozessmessger te nahezu identisch Diese Dokumentation beschreibt die Laborversionen LMA321PA bzw LMA316PA In dieser Dokumentation werden unterschiedliche Einsatzarten im Zusammenhang mit dem Messen der Feuchte und Dichte ber cksichtigt Die Installation des Ger tes und der Sensoren sowie ggf der Anschluss weiterer Peripherieger te ist von Einsatzort und Anforderungen durch das zu messende Produkt abh ngig Deshalb erhalten Sie hierf r weitere separate Dokumenta tionen Lesen Sie diese Dokumentation bevor Sie mit dem Ger t arbeiten Die Dokumentation muss f r die k nftige Verwendung bis hin zur Entsorgung des Ger ts in unmittelbarer N he des Ger ts aufbewahrt werden Andere Dokumentationen Bitte beachten Sie die ge
87. 316PA LMA321PA Bedienoberflache Referenz Ca 5 234 Hinweis Wenn Sie das Programm am PC nutzen dr cken Sie auf bernehmen um die Einstellung zu bernehmen Dr cken Sie auf Einfach um zur einfachen Kalibration zur ckzukehren Dr cken Sie auf Liste um die Parameter f r die gew hlte Kalibration als Liste angezeigt zu bekommen auto Die Kalibration wird automatisch berechnet Falls Sie Einstellungen zur Berechnung der Kalibra tion ndern wollen dr cken Sie auf das Feld Anzeige 1 Kalibration Typ Korrekturen Sie erhalten dann den Dialog zur einfachen Berechnung der Kalibration gt Seite 232 Optionen Feuchtewerte Mindestbereich Hier legen Sie fest wie gro der Abstand zwischen zwei Werten sein muss damit diese f r die Kalibration als g ltig gelten Dies geschieht separat f r den Kalibrations Messwert den Refe renzwert den Korrekturwert und den Temperatur Korrekturwert Diesen Dialog erhalten Sie ebenfalls indem Sie auf das Feld Anzeige 2 Korrelation Std Abw Werte dr cken Automatische Berechnung x aktiviert Nach jeder nderung an den Werten f r die Kalibration wird die Kurve auto matisch neu berechnet g deaktiviert Zur Neuberechnung der Kurve m ssen Sie ab jetzt auf die Anzeige 1 kli cken Deaktivieren Sie diese Option wenn Sie noch umfangreiche Bearbeitungen an den Werten vornehmen So k nnen Sie schneller arbeiten da der Berechnungsvorgang immer eine gewisse Zeit ben
88. 321PA beim Transport nicht aber zum Aufstellen des angeschlossenen Ger ts da hierbei die Kabel besch digt werden k nnen Stellen Sie das LMA321PA auf die Grundfl che und klappen Sie ggf den Tragegriff nach unten wenn das LMA321PA zur leichteren Bedienung etwas schr g gestellt werden soll Touchscreen Kabel anschl sse Tragegriff Wird ein externer Monitor auf das Ger t gestellt darf das Ger t nicht schr g gestellt werden Eine gute Ablesbarkeit des Bildschirms ist durch Kippen des Monitors einzustellen F r die Bedienung sind in diesem Fall eine externe Maus und Tastatur notwendig Hinweis Bevor Sie das LMA316PA LMA321PA bewegen schalten Sie es zun chst aus und ziehen Sie dann alle Kabel auf der R ckseite ab SHE sartorius 153 mechatronics WLM6009 a10081 LMA316PA LMA321PA Inbetriebnahme 4 2 154 Anschlie en Anschlussschema Grundkonfiguration Laborversion Sensor O O 2x Mikrowellenkabel max 3 m O O Sensorkabel Standard bei Black Line Sensoren entf llt bei lteren Sensor Typen o O Netzkabel O O 110 230 V AC T I I d SEH Tastatur Achtung Achten Sie beim Anschluss der Mikrowellenkabel auf die Farbmarkierung Die gr n markierten Anschl sse MW Gen
89. 3xxPA normally only contains test items or pre calibrated items as well as one item which cannot be edited for the measurement of the reference body available as an option see Reference standard Details on page 57 Prerequisite You are logged in with at least level 4 user rights gt page 30 Select the Product settings gt Edit menu item Select the Create menu item Enter the following in the Product settings Details on page 103 dialog General No Enter a unique item number for each product Enter a unique product name to enable the clear identification of the product in the Name field If required add an explanatory text in the Remark e Cal link If a non referenced calibration is being carried out for the product choose self here If the calibration of a similar product is referenced select the ID number of the product in question e Sensor mode Select the sensor and the corresponding mode with which the product is measured Ifthe cor rect mode is not shown you must manually define a mode import one or edit an existing mode definition gt page 110 The device normally detects the modes provided by the con nected sensors Note As a general rule you should first choose a highly sensitive sensor mode If this mode does not return any results reduce the sensitivity by selecting another less sensitive mode Moisture Density e Offset Specify an offset if a similar product is referenced in the cali
90. A LMA321PA The diagram below illustrates the connection of all possible optional components For information on which components form part of your system please refer to the order documentation For a brief description of all LMA316PA LMA321PA connections see page 14 Sensor 2 Sensor 1 O ie C Sensor cable standard for Black Line sensors not required for old er types of sensors ne Network maa eier E connection 110 230 vac O power cable CG r Pt 100 tempera d CT ture sensor a a S USB External monitor Keyboard and mouse O Note The keyboard and mouse cannot be connected using the USB ports The USB ports can be used to connect a printer the supplied USB stick or a USB hard drive Pt 100 temperature sensor connection Except for models featuring an integrated infrared temperature sensor the Pt 100 is not included in the normal package When inserting the connector pay attention to the guide lug in the plug Insert the plug of the Pt 100 temperature sensor into the socket marked with the thermometer symbol on the rear of the LMA316PA LMA321PA and tightly screw on the cover EE sartorius ap mecha
91. A Operator Interface Reference Measurement Calibration These controls are used during measurements and calibrations Only controls which are relevant to the task being carried out can be used 000 Start Start the measurement process This starts the reference measurement during calibration Stop Stop the measurement process Store Saves the currently displayed value ES adjust empty sensor adjust Press this control to confirm that the sensor is presently empty You will be asked whether you want to perform a hard or soft empty sensor adjustment Soft adjustment You simply inform the device that the sensor is empty or that there is an empty measuring cup in the sensor Hard adjustment A hard adjustment is recommended if measuring results seem inaccurate or distorted after relatively long periods of measuring Again you inform the de vice that the sensor is empty At the same time however some internal pa rameters are adjusted so that material wear on the sensor or measuring cup is taken into account A new absolute empty reference point is set To perform an empty sensor adjustment you need to be logged on with appro priate rights Reference standard This function is designed to carry out a technical check of the device on the basis of a reference body which can be acquired as an optional extra For more information see page 57 To execute this function you must be logged onto the software w
92. A316PA LMA321PA Operator Interface Reference Edit Remark EI You can enter a remark for selected entries in the table Once you press Remark corresponding controls become available See Controls in Measurement Calibration Details on page 70 1 Select an entry a block or all entries The same remark is defined for all selected entries 2 To select several rows press Multi Now select several values using the Block 1 Block 2 control or select entries individually Press Remark 4 The Text input Details on page 124 dialog appears Enter the text to be displayed and saved with the value Existing remarks are overwritten 5 Press Close to return to the display O Note Press a row in the table to show the input field for entering a remark on the value in question Delete E You can delete selected entries from the table Attention Deleted readings can no longer be displayed A Once you press Delete corresponding controls become available See Controls in Measurement Calibration Details on page 70 1 Select an entry a block or all entries 2 To select several rows press Multi Now select several values using the Block 1 Block 2 control or select entries individually 3 Press Delete The selected entries are deleted 4 Press Close to return to the display SS uw You can copy selected entries Copied entries are pasted either to the calibration data for a product or the settings for the de
93. Apply to accept the setting sartorius 95 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 96 Delete Individual values can be deleted from the calibration In the menu select Calibration gt Density calibration gt Table gt Edit gt Delete The table is now displayed in delete mode i e the controls page 70 for selecting one or more rows are displayed at the bottom Press a row The value is selected Press Delete The selected value is deleted The system continues to take the value into account until the cal ibration curve is recalculated Press Close The deletion process is complete Note Calibration points can be removed from the calibration without being deleted To do so choose Type and set the point s property to Invalid page 86 This value is not taken into account for the calibration Note If you have a previous calibration that you are satisfied with you can delete the individual values to free up memory space The actual calibration is retained Copy Individual calibration values can be copied In the menu select Calibration gt Density calibration gt Table gt Edit gt Copy The table is now displayed in copy mode i e the controls gt page 70 for selecting one or more rows are displayed at the bottom Copied entries are pasted to the calibration data of a product or to the settings for the density test as selected Select an entry a bloc
94. Bereits gemachte Einstellungen k nnen hier manuell weiter angepasst werden Die zuvor auto matisch errechneten Grenzen der einzelnen Kurvensegmente k nnen verschoben werden Wenn Sie f r die Korrektur der Temperatur oder der Dichte bzw Feuchte Manuelle Korrektur w hlen so wird in der grafischen Darstellung der Kalibrationskurve ein Schieberegler einge blendet Dieser erlaubt es ihnen die Kalibrationskurve manuell zu korrigieren manuelle Korrektur durch Schieberegler oder Zahleneingabe Temp Q Zoom in der grafischen Darstellung 245 100 5 i a Bee EE E WEE EE _ Auf der rechten Seite des Dialoges werden die Ergebnisse der Kalibrationseinstellungen ange zeigt Dr cken Sie auf die Schaltfl che Liste um alle Parameter in Listenform angezeigt zu bekommen Dr cken Sie im Dialog f r die Experteneinstellungen auf Zeigen Die grafische Darstellung wird wieder angezeigt Hier haben Sie jetzt die M glichkeit die Kalibration zu speichern oder aber wieder den Dialog f r die Experteneinstellungen aufzurufen Dr cken Sie auf Auto Eine Auflistung aller mit diesen Parametern m glichen Kalibrationen wird auf der Registerkarte Kalibrationen angezeigt Hinweis Wenn Sie das Programm am PC nutzen klicken Sie auf bernehmen Sie k nnen am PC die einzelnen Programmfenster so verschieben dass Sie Darstellung und Eingabedialog nebeneinander sehen HE sartorius
95. COM service 1 x Ethernet 3 x USB 1 x analogue input 0 4 20 mA for optional IR sensor via sensor connection 1 x connection for Pt 100 temperature sensor Connections for mouse and keyboard PS 2 and VGA screen Environmental conditions Indoor usage altitude up to 2000 m mains voltage fluctuations of up to 10 of nominal voltage overvoltage category Il contamination level 2 Storage temperature 10 C 60 C Sample temperature 0 C to 70 C automatic temperature compensation Highest relative air humidity 80 for temperatures of up to 31 C decreasingly linearly to 50 relative air humidity at 40 C Measuring range 0 1 85 in selectable sub ranges Reproducibility 0 05 standard deviation for 10 measurements Measuring time lt 1 second Product memory 40 standard 20 or 200 optional Data backup Flash memory Dimensions and weight 425 x 335 x 500 mm W x H x D Weight 10 kg Further features and specifications on request EE sartorius gt mechatronics WLM6009 a10081 LMA316PA LMA321PA Help with problems 12 Help with problems This overview will help you to overcome problems when working with the device If the device is working as expected by incorrect measured values seem to be displayed please read the follow ing What must be taken into account when calibrating Details on page 29 Error messages Details on page 128 Problem Corrective act
96. Cleaning DANGER Risk of death from electric shock Prior to cleaning turn off the device and disconnect it from the mains Do not immerse the device in water or other liquids Do not use aggressive chemical substances scouring material hard sponges or similar for cleaning Do not exert too much pressure on the touchscreen when cleaning it Clean the housing and screen with a slightly damp cloth when required Water must not be allowed to enter the interior of the instrument Wipe the instrument dry afterwards Transport and storage Keep the original packaging in which the instrument was delivered If you need to transport or store the instrument later on you must use the original packaging The following environmental conditions must be observed when storing or transporting the instrument Temperature 10 C to 60 C Rel humidity Max 85 non condensing Disposal Packaging that is no longer required must be disposed of at the local waste disposal facility The packaging is made of environmentally friendly materials that can be used as secondary raw mate rials The device including accessories and batteries cannot be disposed of in your regular household waste European legislation requires that electrical and electronic equipment be collected and disposed of separately from other communal waste so that it can be recycled In Germany and many other countries Sartorius AG takes care of the return and legally compliant disposa
97. Configuration gt Printer config The Printer Configuration dialog is displayed O Note The Printer Configuration plug in is only available in English 2 Choose Add New Printer to add a printer O Note When entering the printer name you must not use any blank spaces or the characters and 3 Use the virtual keyboard to enter a printer name that can then be used to select this printer in TMV Then press Apply The dialog automatically switches to the Printer Device tab Printer Configuration Administration Printer Device Make Model Driver Printer Options Printer Version 0 1 4 HP_LaserJet ia Ss ostname Port Queue Device URI usb HP LaserJet 201020 Set New Device URI Device Info usb HP LaserJet 201020 lt a gt Back Next AE Help 4 Under Device select the USB printer and choose Next Under Make on the Make Model Driver tab select the printer manufacturer and then select the type of USB printer under Model 6 Press Add Printer lt name gt The USB printer is added to the list of printers that are available in TMV 7 After pressing OK in the message stating that the printer was added the system displays the Printer Options tab in which you can define the default settings for the printer The possible options depend on the relevant printer driver If not all options can be displayed at once you can use Up and Down to switch to other options
98. Details auf Seite 249 Globale Einstellungen Details auf Seite 249 Ansicht Nachkommastellen F r die angezeigten Messwerte Feuchte Dichte Temperatur sowie die angezeigten Kalibra tions Messwerte legen Sie fest wieviele Dezimalstellen angezeigt werden 1 Dr cken Sie auf ein Listenfeld 2 Dr cken Sie auf die entsprechende Ziffer O Hinweis Unabh ngig von der Anzeige werden intern alle Werte mit wesentlich h herer Genau igkeit gespeichert Statuszeile Erweitert 1 Aktivieren Sie diese Option f r eine erweiterte Anzeige in der Statuszeile 2 W hlen Sie Feuchte und oder Dichte wenn diese Werte in der Statuszeile angezeigt werden sollen Schriftgr e 3 Bestimmen Sie hier die Schriftgr e f r die Anzeige in der Statuszeile Virtuelle Tastatur x Option aktiviert Eingaben f r Werte und Texte k nnen nur ber die virtuelle Bild schirmtastatur gemacht werden oO Option deaktiviert Statt der virtuellen Tastatur wird ein einfaches Eingabefeld einge blendet Werte und Texte werden direkt ber die angeschlossene Tastatur eingetippt Ganzer Bildschirm Diese Option ist nur bei TMV auf externen PCs bearbeitbar da auf Touchscreen Ger ten das TMV Fenster grunds tzlich an den Bildschirm angepasst wird x Option aktiviert Das TMV Fenster wird automatisch an den Bildschirm angepasst Option deaktiviert Das TMV Fenster wird mit der Standardgr e ge ffnet bzw mit der zuletzt vom Bediener eingestellt
99. Dr cken Sie an eine Stelle der Grafik Der Cursor wird an diese Position gesetzt Bei Wechsel zur Tabellen Darstellung 2 Seite 214 bleibt die Cursorposition erhalten Nutzen Sie die Schaltfl chen f r die Navigation Details auf Seite 212 um den Cursor an eine bestimmte Stelle zu setzen oder um weitere Werte der Messreihe anzuzeigen Hinweis Dr cken Sie einmal auf die Schaltfl che Zum Ende Die Schaltfl che bleibt gedr ckt das hei t blau hinterlegt Der Cursor bleibt nun an der Position der letzten aktuellen Messung stehen Die Grafik wird laufend aktualisiert Dr cken Sie auf die Betriebsartanzeige Messung oder das Grafik Symbol um zur Werteanzeige umzuschalten Die Schaltfl chen Vergr ern und Verkleinern erm glichen einen detaillierten Blick bzw einen gr beren berblick Bei vergr erter Darstellung wird die Kurve so dargestellt dass der Cursor im Zentrum der sicht baren X Achse steht Wenn Sie durch Antippen der Grafik den Cursor an eine neue Position ERE sartorius a o mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz sartorius aly setzen wird die Darstellung des angezeigten Ausschnittes entsprechend verschoben Eine Balkenanzeige oberhalb der Grafik verdeutlicht welcher Ausschnitt der Gesamtkurve zur Zeit angezeigt wird Wenn Sie hier nur ein leeres Rechteck sehern dann wird die Kurve fur den gesamten Verlauf der Messungen angezeigt Drucken Sie links oder re
100. Druckers finden Sie auf Seite 198 Wahlen Sie im Men Messung gt Grafik gt Drucken Die Grafik wird so wie sie am Bildschirm dargestellt wird ausgedruckt Werte Diese Art der Darstellung nutzen Sie um einen bzw zwei aktuell gemessene Werte klar und bersichtlich anzuzeigen Es wird der aktuell gemessene Wert angezeigt Eine Navigation zwischen Messwerten ist nicht m glich Sie k nnen die Messung stoppen und wieder starten QO Sie k nnen einen Leerabgleich durchf hren D 1 Dr cken Sie auf die Betriebsartanzeige Messung oder das Zahnrad Symbol um zur Tabelle um zuschalten Einstellungen Wert 1 Dr cken Sie auf eines der beiden Listenfelder um die Messwerte auszuw hlen die angezeigt werden 2 W hlen Sie zwischen Feuchte Dichte Temp Temperatur Aus keine Anzeige diese Einstellung ist nur im zweiten Feld m glich 3 W hlen Sie zwischen Letzter Wert Es wird der zuletzt ermittelte und gespeicherte Wert angezeigt Dieser Wert wird unter Umstan den als Mittelwert aus mehreren Messungen ermittelt Statuszeile Es wird der Wert angezeigt der auch in der Statuszeile angezeigt wird Dieser Wert entspricht dem momentan gemessenen Wert Dieser Wert ist unter Umstanden nicht gespeichert Diese Einstellung ist f r beide Anzeigen g ltig 4 Dr cken Sie auf bernehmen Die Werte werden entsprechend den gew hlten Einstellungen I angezeigt SHE sartorius 221 cece 3
101. E gt 0 206 L ae ee S 0 198 I BER u Non linear calibration Fe ae curve with Tf 0 182 IT four segments 15 9 16 7 175 18 3 19 1 19 9 20 7 21 5 22 3 23 1 Note You can refine a calibration by measuring further samples later on In particular this is necessary if the product is subsequently measured in a different value range Logging in to carry out calibration or create products To create new products or carry out a calibration for a product you must first log in with appro priate rights calibration requires at least level 3 and creating new products requires at least level 4 This prevents the unauthorized changing of system settings which could result in incorrect measurement results Select the Change user menu item On the Login screen enter your user name and password Click Apply The Calibration Product settings System settings and Service functions are now available Note After carrying out administrative work you should either change your login to your normal access rights or if a default user is defined turn off the device to prevent unauthorized modifica tions of the system settings or calibrations Creating a product You must make appropriate product settings on the device for each product for which moisture or density is to be measured EE sartorius a eegg mechatronics WLM6009 a10081 LMA316PA LMA321PA Calibration ew bz When delivered the LMA3xxPA PMD
102. ET EE 209 Bibliothek Sensormodi e 253 C GHIONIK ui aa a geheie dee 213 E le 206 Position 215 Position ndern 212 Position festlegen 218 D Datum u a ee us 248 Dichtek frektur sccssicdicctesaidicctersoidadeavaeraided nia 231 Drucker einrichten ccecsecececeeeeeeseeeeeeeaaees 198 HE sartorius mechatronics LMA316PA LMA321PA Stichwortverzeichnis E Einstellungen Global an el 2 aaa es 249 ETC 219 Grafik Verdichtungstest 263 Experte Kalibration 233 242 Extremum ccccccccccccecceeeeseeeeseaeaeseaeaeeees 232 241 F FabrikeinstellUngen nn 189 Feuchtekorrektur A 240 Feuchte Offset 244444444444 nennen 167 G Ger teinitialisierung 4440er nennen 250 Globale Einstellungen een 249 ETC E 218 Vergr ern 0 eee 218 H harter Leerabgleich 4 nen 210 SE 255 ermitteln 164 Voreinstellung 163 K RAIN u a nalen 167 Kalbrationstyp linear 2 A8 EE an 232 241 nichtlinear 22222222222 232 241 let e TR 225 Dichte 2 sel eee dace en 235 Experte A Gutt a ee 233 242 Expertenmodus 178 Feuchte 4 sten reset 226 Offset ass ae ae 176 Proben then and adds hapten ede 165 Produktauswahl 225 Punkt Twp eee eee eee 227 236 TYP EE 177 232 241 Werte herausnehmen 175 Werte l schen 176 Kalibreren en 172
103. Eintrag einen Block oder alle Eintr ge F r alle markierten Eintr ge wird dieselbe Bemerkung erstellt Um mehrere Zeilen zu markieren dr cken Sie auf die Schaltfl che Mehrere W hlen Sie nun mithilfe der Schaltfl che Block 1 Block 2 mehrere Werte aus oder markieren Sie einzelne Eintr ge Dr cken Sie auf Statistik Die Statistik wird entsprechende Einstellungen vorrausgesetzt in einem der Anzeigefelder rechts oben dargestellt Zur Konfiguration der Anzeigefelder lesen Sie Statistik Details auf Seite 224 Dr cken Sie auf Schlie en um zur Anzeige zur ckzukehren Grafik Die Messwerte werden als Grafik dargestellt Die grafische Darstellung zeigt Ausrei er der Messreihe und Tendenzen in der Entwicklung der Werte F r die horizontale Werte Achse X Achse kann f r die Darstellung zwischen Position oder Zeit punkt der Messung gew hlt werden Es k nnen wahlweise eine oder zwei Messkurven angezeigt werden Feuchte Dichte oder Temperatur Diese und weitere Einstellungen nehmen Sie vor im Men punkt Messung gt Grafik gt Einstel lungen Details auf Seite 219 Zum Starten und Stoppen der Messung sowie zur Probeentnahme und zum Leerabgleich nutzen Sie die Schaltfl chen zur Messung Kalibration Details auf Seite 210 Cursorposition festlegen Die Werte der Messung an der Cursorposition k nnen in einem der Anzeigefelder Anzeige 1 2 Messung Details auf Seite 208 genau dargestellt werden
104. Falls Sie in ein anderes Verzeichnis L t installieren m chten klicken Sie auf Durchsuchen und w hlen Sie ein anderes Verzeichnis aus mm Klicken Sie auf Weiter um fortzufahren E Wm L i C Programme TMv Durchsuchen Ben tigter Speicher verf gbarer Speicher lt Zur ck Weiter gt e Zielverzeichnis Das Standardverzeichnis ist C Programme TMV M chten Sie die Software in einem anderen Verzeichnis oder auf einem anderen Laufwerk installieren k nnen Sie dies ber die Durchsuchen Funktion einstellen Alternativ zur Durchsuchen Funktion k nnen Sie den gew nschten Pfad auch direkt in das Feld eingeben sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Steuerung ber externen PC e ltere Version Sollte bereits eine fr here Version von TMV auf diesem PC installiert sein so schl gt das Installationsprogramm automatisch das Verzeichnis dieser fr heren Version vor Diese Version wird dann mit der aktuellen Software Version berschrieben siehe Hinweise zu Software Updates Details auf Seite 162 Speicher Unterhalb des Eingabefeldes wird angezeigt wieviel Speicherplatz f r die Installation ben tigt wird und wieviel freier Speicherplatz auf dem gew hlten Laufwerk noch verf gbar ist Falls der freie Speicherplatz nicht ausreicht w hlen Sie ein anderes Laufwerk ber Durchsu chen oder l schen Sie vor der weiteren Installation nicht mehr ben tigte Dateien auf dem gew hlte
105. Ger t Details auf Seite 257 Druckerkonfiguration Details auf Seite 257 Benutzerkonfiguration Details auf Seite 258 Sensormodi In der Tabelle werden alle verf gbaren Sensormodi dargestellt F r diese Einstellungen m ssen Sie mit Zugriffsrechten mindestens der Stufe 4 angemeldet sein Sensormodi die vom Hersteller definiert werden sind mit einem gr nen H kchen markiert Von Ihnen selbst definierte Modi werden nicht gekennzeichnet Das Men hat folgende Unterpunkte Bearbeiten Details auf Seite 251 Einstellungen Details auf Seite 253 Drucken Details auf Seite 253 Export Details auf Seite 253 Einlesen Details auf Seite 253 Bearbeiten Werte Hinweis F r diese Einstellungen m ssen Sie mit Zugriffsrechten mindestens der Stufe 4 angemeldet sein Dr cken Sie auf eine Zeile um diese zu markieren Hinweis Sie k nnen mehrere Zeilen markieren und gleichzeitig bearbeiten Automatisch einge lesene Sensormodi k nnen nicht ver ndert werden Dr cken Sie auf die Schaltfl che zum Bearbeiten Sie erhalten den Dialog Sensormodus Dr cken Sie auf ein Eingabefeld Sie erhalten den Dialog zur Zahleneingabe Details auf Seite 268 bzw zur Texteingabe Details auf Seite 267 ERE sartorius 251 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz pl Bibliothek vd E 6 wi 252 Dr cken Sie auf Bibliothek W hlen Sie einen Sensormodus aus der Liste D
106. Kalibrieren 170 808 Hilfe Chronik a Feuchte 10 78 26 3 C 5 3 3 3 Verdichtungs Test Graph Type A B Current Type BI ns Regression Tree Measure single 5 TEST GG 0 000 Sensor Mode P145 110 Werte 12 12 10 Anzeige 1 Anzeige 2 Verdichtungstest Messungs Eigenschaften einstellungen Messparameter Die Parameter zur Vorgehensweise bei der Messung bestimmen Sie im Dialog Messungsein stellungen W hlen Sie Service gt MW test gt Verdichtungs Test gt Measure Settings oder dr cken Sie auf das Feld Anzeige 2 Aktivieren Sie die Option continuously wenn fortlaufend im Sekundentakt Messwerte f r den Verdichtungstest gewonnen werden sollen Prozessmessger te bzw deaktivieren Sie die Option wenn jede Messung einzeln durchgef hrt und gespeichert werden soll Laborger te Aktivieren Sie die Option overwriting wenn bei berschreiten der f r den Test reservierten Speicherkapazit t alte Messwerte berschrieben werden sollen Speicher Bestimmen Sie hier wieviel Speicherpl tze f r den Test in Anspruch genommen werden sollen Aktueller Typ Bestimmen Sie hier die Darstellung der Messpunkte in der Grafik Einstellungen und Bewertung der Ergebnisse Zur Bewertung der Testergebnisse w hlen Sie die grafische Darstellung Dr cken Sie auf die Grafik um den Dialog Verdichtungstest Eigenschaften Details auf Seite 171 aufzurufen HE sartorius seg mechatronics WLM6
107. Konfiguration seien 251 Benutzer einrichten 195 Drucker einrichten 198 Sensormodi 196 L Leerabgleich u 210 281 WLM6009 a10081 M UE UE 205 Ziffernfolge 206 Zur ck 222 Re er Rn Er nr 206 Messung Labor 42 24 2288 22428 E e 181 Messverfahren cecececcccccceeceeeseeesaeseseseaeeeeees 172 Messwerte Gialli se en en ee ne 218 Gro anzeige 2 nenn 221 Tabelle Rense 214 MW device u serielle 250 N NetzwerkeinstellUngen ne 255 Neu Angeschlossenes Ger t 255 Benutzer 00 eee 195 258 Kalibrationswert 229 Produkt 245 O freet hRS AEN 246 ANZEIGE A n ne en dere 209 P Printer Configuration us es 198 Produkt nie han 209 anlegen A ese Pee EE EH ne 167 gesch tzt bebe HR 244 Parameter bearbeiten 244 Speicherplatze 167 Produktauswahl Kalibration 225 262 Messung u 24 ita AE 214 ProdukteinstellUNgen 167 244 R Referenzstandard cccccccccecececseeeseeeeeeeeeaeees 210 Referenzwerte cccccccccccccceeeeeseseeseseseseaeeeeees 174 Reset 266 RESTOS aoieanna a a E 188 S SchnellZugriffe nesini 275 Sensormodi eeesssessssssnneneneeneneeeeeennnnnnnnnnnnnn 196 Bibliothek scce 2025 20 22444 20444 253 SENSOFMOdUS 167 Shortcuts seess deed Een EEN 275 Sicherungen east 190 Speicher niederen 167 Sprache nee nern 266 SPF
108. M6009 a10081 LMA316PA LMA321PA 8 Kurzanleitung Messen Vorsicht AN Wenn Sie diese Kurzanleitung aus dem Handbuch herausnehmen m ssen Sie daf r sorgen dass alle Personen die damit arbeiten die Sicherheitshinweise ab Seite 143 und bei einzelnen Arbeitsschritten im Handbuch kennen und beachten O Hinweis Diese Kurzanleitung beschreibt einen blichen Arbeitsablauf beim Messen mit dem Laborger t mit Touchscreen Beschreibungen zu anderen Ger tetypen und ausf hrlichere Infor mationen finden Sie im Handbuch und in der Online Hilfe Einige der beschriebenen Funktionen sind abh ngig von Ihren Zugriffsrechten und stehen Ihnen daher m glicherweise nicht zur Verf gung bersicht ber Ger t und Bedienoberfl che Display R ckseite Vorderseite Ein Ausschalter Display Touchscreen Betriebsanzeige Bedienoberflache Ment Statuszeile Hilfe m x a Feuchte 9 19 Dichte 4 19 26 8 C a 12 Hilfe Chronik hltes SS SS gewa Messung E le ain Ser Produkt Coffee soo 70 Feuchte 100 30 Dichte 60 Nr Datum Zeit Bemerkung Feuchte Dichte Temp 149 149 2007 01 31 10 06 29 BEMERKU 711 334 255 150 150 2007 01 31 10 06 31 BEMERKU 7 10 3 34 255 151 151 2007 01 31 10 06 33 BEMERKU 7 16 3 34 255 152 152 2007 01 31 10 06 35 BEMERKU 7 15 3 35 ag Tabe
109. M6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz O J 2 236 Hinweis Zur Eingabe eines Referenzwertes des Typs oder einer Bemerkung k nnen Sie auch auf das entsprechende Feld im Tabelleneintrag dr cken Sie erhalten dann den Eingabedialog Hinweis Entsprechend den Einstellungen f r Globale Einstellungen Details auf Seite 249 werden Werte gerundet angezeigt Bei der Eingabe geben Sie alle Dezimalstellen ein Dr cken Sie auf Schlie en Die Eingabe ist beendet Bemerkung Sie erhalten den Dialog zur Texteingabe Details auf Seite 267 Der Text der Bemerkung kann frei gew hlt werden Dr cken Sie auf bernehmen um den Eintrag in die Tabelle zu bernehmen Hinweis Dieser Dialog erscheint automatisch nach jeder Messung eines Kalibrationswertes Hier geben Sie typischerweise die Nummer der Probe ein So k nnen Probe und Messwerte eindeutig zugeordnet werden Referenzdichte Sie erhalten den Dialog zur Zahleneingabe Details auf Seite 268 Geben Sie den Laborwert f r die Dichte der Probe mit allen Nachkommastellen ein Die Anzeige erfolgt entsprechend den Einstellungen gerundet Dr cken Sie auf bernehmen um den Eintrag in die Tabelle zu bernehmen Dieser Dialog erscheint automatisch nach jeder Messung eines Kalibrationswertes Typ Sie haben die M glichkeit einzelne Punkte der Kalibrationskurve durch unterschiedliche Symbole darzustellen So lassen sich in der Kalibrationskurve z B Messungen
110. Messung Hier stehen zwei Anzeigefelder zur Verf gung Jede der beiden Anzeigen kann individuell einge stellt werden Cursor Dees 3 00 Dichte 6 00 Angezeigt wird entweder der aktuell gemessene Wert oder der Wert an der Cursorposition f r Feuchte Dichte oder Tem peratur oder die Statistik f r ausgew hlte Messwerte oder f r alle Messwerte 1 Dr cken Sie auf eines der Anzeigefelder um Einstellungen f r die Anzeige zu ndern Lesen Sie dazu den Abschnitt Analoganzeige Details auf Seite 222 Im Men w hlen Sie Messung gt 1 2 Anzeige um die Art der Anzeige zu ndern Anzeige 1 2 Kalibration Wahrend einer Kalibration werden in den Anzeigefeldern Informationen zur Kalibration ange zeigt Kalibration Korrelation 1 000 Typ linear Std Abw 0 002 Korrekturen 0 Werte 2 auto o Typ Hier wird der Kalibrationstyp angezeigt linear oder nicht linear gegebenenfalls in Segemente unterteilt 208 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz Werte Hier wird angezeigt die Anzahl der Kalibrationspunkte und obdie Kalibration automatisch berechnet wird und ob gegebenenfalls auch die Grenzen der Seg mente automatisch neu berechnet werden Zur Berechnung einer Kalibration werden mindestens zwei Kalibrationswerte und die dazugeh rigen Referenzwerte ben tigt 1 Dr cken Sie auf das Anzeigefeld Kalibration um Einstellun
111. Navigation Details on page 72 or by pressing in a particular spot on the graph Days specifies the number of days to be shown The value selected in Span and the value selected here are added together Displayed period Span Days Pause The device can identify an interruption in the current measuring cycle as a pause If pauses are detected the graphical display is interrupted accordingly Enter the required time period between two measurements for a pause to be recognized If Pos is selected Span is the number of positions measured values to be depicted The smallest possible value is 2 Y axis One or two curves can be shown in the graph as desired You define which measured values are to be displayed here Value Press one of the two list fields to select the measured values to be displayed Choose from the following Moisture Density HE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Temp temperature Off no display only available in the second panel auto X Press the box to automatically adjust the scale of the Y axis All of the readings in the measure ment series are then shown The scale can be selected differently for two curves The values for the first curve are shown on the left in the corresponding colour and those for the second curve are shown on the right If auto is deactivated use the input fields to selec
112. New from the Edit menu The Device properties dialog appears 2 Press an input field The Numerical input Details on page 125 or Text input Details on page 124 dialog appears 3 Press Apply VG This creates the entry for a new device EE sartorius 113 a mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference A 114 Settings The Settings dialog appears You can customize the depiction of the table for displaying the product settings here See Settings for tables Details on page 126 Print You can print out the parameters for one or more devices The table is now displayed in print mode i e controls page 70 for selecting one or more rows are displayed at the bottom Press a row to select it Press the Print button How you now continue depends on whether the printer is connected directly to the measuring device or if you are working on an external PC Press Close The printing of the values is complete Export The table is exported to a csv file and stored on the connected USB stick Press Edit to change the file name Note If you are using the program on your PC the Export dialog appears Specify a storage location on the PC and change the name of the export file if necessary Note Microsoft Excel 2003 The widespread and universal csv export format cannot be properly interpreted for Excel 2003 Rename the csv file as txt and import it int
113. Prozessmessung x Option aktiviert Das Messger t startet nach dem Einschalten automatisch mit den Messungen Option deaktiviert Nach dem Einschalten m ssen Sie das Messen manuell in TMV starten indem Sie auf die Start Schaltfl che dr cken Simulation Falls das Ger t zur Pr sentation eingesetzt wird l uft die Software ggf im Simulations Modus Dies wird hier angezeigt Temperatur Produkttemperatur Diese Einstellungen beeinflussen die Temperaturkorrektur bei der Kalibration Quelle W hlen Sie hier aus ob und mit welchem Temperatursensor Sie die Temperatur des Produkts messen Die in der Liste angebotenen Auswahlm glichkeiten sind abh ngig von Ihrer individuellen Systemkonfiguration Die Temperaturmessung kann auch deaktiviert Quelle Aus oder mit einem vordefinierten Wert Quelle Fest versehen werden Port Wird zur Temperaturmessung einer der Analogausg nge einer TC MPC Karte verwendet wird hier festgelegt welcher der vier Ausg nge verwendet werden soll Fest Ist als Quelle der Eintrag Fest ausgew hlt kann hier der Temperaturwert eingegeben werden der f r die Messungen grunds tzlich verwendet werden soll Stabilit t W hlen Sie die Zeitspanne in Sekunden und den Schwankungsbereich in Grad Celsius aus Wenn die gemessene Temperatur innerhalb der gew hlten Zeitspanne nicht um mehr als den gew hlten Wert abweicht gilt sie als stabil Analog Falls Sie die Temperatur Analog oder ber die IO MPC mes
114. SHE sartorius mechatronics Operating Instructions Betriebsanleitung Sartorius LMA316PA LMA321PA Microwave Moisture Analyzer Mikrowellen Feuchtemessgerat Mat Nr 98648 018 36 WLM6009 a10081 LMA316PA LMA321PA Englisch 3 Deutsch 139 WLM6009 a10081 LMA316PA LMA321PA Table of contents 1 Before you begin 5 9 Other functions 49 1 1 Overview of the documentation 5 9 1 Defining users with different access 1 2 Other manuals 5 profiles 49 13 For technical advice on applications 5 9 2 Sensor modes 50 1 4 Information on on line help 6 9 3 Setting up printers 53 1 5 Writing conventions in this documentation 6 9 4 Reference standard 57 2 Safety instructions 7 10 Service and maintenance 59 2 1 Intended use 7 10 1 Software update 59 2 2 Unsafe conditions 7 10 2 Creating a backup restoring the system 59 2 3 Changes 7 10 3 Replacing fuses 61 2 4 Installation and Maintenance 8 10 4 Cleaning 62 2 5 Qualification of operating personnel 8 10 5 Transport and storage 62 2 6 Warnings 8 10 6 Disposal 62 3 Product description 11 11 Technical data 63 3 1 View of the device front view 12 A 3 2 View of the device LMA316PA 12 Help with problems 64 LMA321PA connections at the rear 13 3 3 Scope of delivery 16 13 Operator Interface Reference 65 i 13 1 Menu 65 4 Control via external PC 17 432 Display panel 66 4 2 Installing TMV 17 13 4 Measurement 73 4 3 Linking up measuring device and PC 20 13 5 Calibration 84 13 6 Product
115. The warning triangle containing the exclamation mark and the word DANGER warns you about the risk of potential serious injuries or fatal injuries Caution The warning triangle containing the exclamation mark and the word Caution warns you about the risk of potential minor injuries or property damage Attention The warning triangle containing a broken diskette warns you about the risk of data loss or of gen erating incorrect data Prerequisites This indicates prerequisites that must be met before the next steps are taken Note Texts marked in this way contain useful notes and further information Terms that can be found on the user interface are highlighted in bold This also applies when referencing other sections of this documenta tion and when referencing further documentation Menu items are separated by arrow brackets Menu gt Submenu gt New Copyright information Excel Microsoft Windows and Windows Vista are registered trademarks or trademarks of the Microsoft Corporation in the USA and or other countries HE sartorius coe mechatronics WLM6009 a10081 LMA316PA LMA321PA 2 Safety instructions 2 1 Intended use The installation as delivered may only be used for the purpose stated in the quotation or the order confirmation taking into account the technical data Utilisation other than for the intended use is not permissible The function and operating safety of the device can only be ensured if during op
116. UNG een 212 StandardbenutZer oo ccececsseesesssssseseeseeeeees 259 282 LMA316PA LMA321PA Stichwortverzeichnis Start Messung 181 Schaltfl che 2 222222 210 Starten Programm 162 Statistik erzeugen nenn 218 Status 2nnnssnenennennnnennnennennnnnnnnnannnnnnnnnn nn 208 Stopp Messung 181 Schaltfl che 222222 c er 210 Symbol Kalibrationspunkt 228 236 T Tabelle Bearbeiten 2 2 0200000 211 Bemerkung 215 Block markieren 211 Eintrag kopieren 211 216 Eintrag l schen 211 216 Sortieren 269 Spalte ausblenden 269 Spalte bewegen 269 Statistik erzeugen 211 Tabellenansicht ne 214 Tastatur Anschluss 222mm een en 154 virtuell 249 Temperatur Sensor 2 nennen nn 250 Temperaturkorrektur_ 231 240 Touchscreen 2 eeceeeeeceeeceeeeeeeeeeeeeeseteneaeeees 205 Typ GUNG ass en ea 227 236 Kalibration 232 241 Kalibrationspunkt 227 236 Symbol u are wwe 228 236 U USB Dr cker u 200 V Verdichtungs Test ssssnnnennenssnnnnnnn nn 169 Versionsnummer nnsssssssssssnsesssssrtetrrnrrnnsnnreernennn 264 virtuelle Tastatur 02244444 nennen 157 W weicher Leerabgleich u nn 210 Werteanzeige ussssssnnnnnnnssnnnnnnnnnnnnnnnnnn nn 221 Wiederherstellen 188 Z KEE 248 ZOOM un EES 230 239 Zugriffsr
117. ails on page 46 Displaying values You can display multiple measured values together and in different ways Each of the displays can be adapted to the requirements of the application environment There are the following display options Displaying values as a table page 74 graph gt page 77 or values page 80 Displaying measurements for moisture density or temperature Displaying an analogue depiction of the value at the cursor position or of the selected value page 81 Displaying the statistics for a measurement series For information on making display settings see the appropriate sections in Operator Interface Reference Details on page 65 EE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Taking measurements 8 1 46 10 11 o o ton Taking measurements in the laboratory Note Device messages are displayed in the status line For more information on the touchscreen and how to use it see Operator Interface Reference Details on page 65 Turn on the device if it is not already turned on The switch is on the back of the device Recommendation After switching on the device wait a few minutes before taking the first meas urements since this allows the device to reach its optimum operating temperature Note Ifthe device is already switched on a different area of the software may be active e g the Product settings dialog If this is the case selec
118. alues to be clearly assigned to each other Reference density The Numerical input Details on page 125 dialog appears Enter the laboratory value for the density of the sample with all decimal places The display of the values is rounded off in accord ance with the settings Press Apply to add the entry to the table This dialog is displayed automatically following every measurement of a calibration value Type You can depict individual points on the calibration curve using different symbols This allows you to display measurements made on different days more clearly on the calibration curve for example Press an input field to display the Type dialog Select whether the calibration point is to be used for the calibration x The calibration point is valid and is used to calculate the calibration curve The value is not taken into account for the calibration However the entry remains in the table and can be set to Valid at a later time if required Symbol Press the list field and select a symbol In the calibration graph the calibration point is represented by the selected symbol Press Apply to accept the setting All values The Calibration properties dialog appears Existing information is shown Press an input field The Numerical input Details on page 125 or Text input Details on page 124 dialog appears If you selected the option for entering the type the Type gt page 86 dialog is displayed Press
119. an be meas ured in their natural state The product surface granularity structure colour etc does not influ ence the measurement nor does the product undergo any changes or temperature differences as a result of the measurement The calibration curve recorded once is independent of type This means that a mixture of types and products whose production parameters have been changed can also be measured using a single calibration curve Furthermore the use of addi tives such as minerals or salts only has a minor influence The moisture value determined on the basis of the previously performed calibration is shown immediately on the display The TMV software enables storage of the measured values if required Any number of different items together with the corresponding calibrations and measurement data can be saved in the device memory the number is limited only by the actual memory capacity A backup function is also available for saving stored data which enables you to copy data to a USB stick or an external PC It is also possible to restore stored data from the USB stick or external PC to the measuring device EE sartorius mM cece 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Product description 3 1 View of the device front v
120. ardware Fehler 3 0 0 Fehlender Leerabgleich oder MW Sensortemperatur F hren Sie einen Leerabgleich Seite 210 durch Falls Sie die Option Temperaturkoeffizienten im Dialog Sensormodus aktiviert haben m ssen Sie einen Sensor anschlie en der Temperatur werte liefert Den Dialog Sensormodus erhalten Sie ber den Men befehl Systemein stellungen gt Konfiguration gt Sensormodi gt Bearbeiten gt Werte siehe hierzu auch Informationen auf den Seiten 196 und 251 4 x 0 0 Messwerte nicht im zul ssigen Bereich F hren Sie einen harten Leerabgleich durch 2 Seite 210 Pr fen Sie in den Eigenschaften des Verdichtungstests die Parameter unter Messbereich MR Mhz x 9 Parameter A min zu gro x 10 Parameter A max zu klein x 11 Parameter B min zu gro x 12 Parameter B max zu klein Den Dialog Verdichtungstest Eigenschaften erhalten Sie ber den Men befehl Service gt MW test gt Verdichtungstest gt Grafik gt Einstellungen 272 EE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz Fehlercode Ursache und Abhilfe 6 x 0 Die gleitenden Mittelwerte float sind nicht im zulassigen Bereich siehe 4x0 7 0 0 Kalibration kann nicht berechnet werden da die Produkt Temperatur Men befehl Kalibration gt Feuchte Kalibration bzw Dichte Kalibration gt Typeneinstellung Kalibrationstyp f r die Korrektur der Kalibration fehlt Pr f
121. arity Press the All calibrations list field and select a filter Press an entry to select it Press Choice to apply these parameters for the calibration Press Display to return to the graphical display or table view In the graphical depiction or table view press Save to save the calibration or return to the dialog with the expert settings O Note If using the program on your PC press Apply to adopt the setting Press Simple to return to the simple calibration process Press List to display the parameters for the chosen calibration in a list CIS ep auto The calibration is calculated automatically If you want to change the settings for calculating the calibration press the 1st display panel calibration type correction The dialog for the simple calculation of the calibration gt page 100 appears Sartorius 101 mechatronics WLM6009 a10081 102 LMA316PA LMA321PA Operator Interface Reference Options Density value minimum range Specify the minimum difference between two values for those values to be valid for the calibra tion Separate minimum differences are set for the measured calibration value reference value correction value and temperature correction value You can also call up this dialog by pressing the 2nd display panel correlation standard devia tion values Automatically calculate Activated The curve is automatically recalculated each time the calibration values change
122. armbereichs angezeigt Die Werte werden bei den Produkteigenschaften Seite 244 festgelegt Letzter Wert Cursor W hlen Sie hier ob der angezeigte Wert der aktuell gemessene Last oder der Wert der momentanen Cursorposition Cursor ist 2 Dr cken Sie auf Statistik um in dem Anzeigefeld Statistiken anzuzeigen Lesen Sie hierzu Statistik 3 Dr cken Sie auf bernehmen Die Werte werden entsprechend den gew hlten Einstellungen 2 angezeigt SHE sartorius 223 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz W III 224 Statistik Alternativ zur analogen Anzeige kann in jedem der beiden Anzeigefelder eine Statistik angezeigt werden Die Anzeige kann f r Feuchte oder Dichte erfolgen Angezeigt wird die Statistik f r alle gespeicherten Messwerte Sie k nnen jedoch in der Tabelle einzelne Positionen markieren und f r diese gew hlten Messwerte eine Statistik erzeugen Lesen Sie dazu Statistik Details auf Seite 218 Angezeigt werden Feuchte bzw Dichte und die Anzahl der Positionen f r die die Statistik erzeugt wurde der arithmetische Mittelwert die Standardabweichung Einstellungen Diesen Dialog erhalten Sie ber das Men oder indem Sie auf eines der Anzeigefelder dr cken Wert Dr cken Sie auf das Listenfeld und w hlen Sie ob die Statistik f r Feuchte oder f r Dichte an gezeigt wird Dr cken Sie auf Analog um in dem Anzeigefeld Werte anzuzeigen Lesen Sie
123. asst Werte Drucken Ausgew hlte Messwerte k nnen ausgedruckt werden Hinweise zum Anschluss eines Druckers finden Sie auf Seite 198 W hlen Sie Service gt MW test gt Verdichtungstest gt Tabelle gt Drucken Die Tabelle wird nun im Modus zum Drucken angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen zum Markieren einer oder mehrerer Zeilen Markieren Sie die Zeilen die gedruckt werden sollen Dr cken Sie auf die Schaltfl che Drucken Die entsprechenden Tabellenzeilen werden ausgedruckt Dr cken Sie auf Schlie en Das Drucken der Werte ist beendet sartorius 171 mechatronics WLM6009 a10081 LMA316PA LMA321PA Kalibrieren 6 5 172 Kalibrieren Die Kalibration wird f r Feuchte und Dichte separat durchgef hrt Die Vorgehensweise ist jedoch gleich Voraussetzungen e Sie sind mit Benutzerrechten ab Stufe 3 angemeldet 2 Seite 166 Sie haben das Produkt angelegt 2 Seite 167 Die Anlage ist bereit Messungen durchzuf hren Sensor angeschlossen Es stehen Proben vom Produkt in der Beschaffenheit zur Verf gung in der das Produkt sp ter gemessen werden soll Unterscheidung der Messverfahren Grunds tzlich werden je nach Einsatzart folgende Formen der Messung bzw Kalibrierung unter schieden Labormessung Einfachmessung z B Zigarette Fur die Kalibration wird nur ein Messwert ermittelt Mehrfachmessung z B mit Sch ttgut im Messbeh lter Es werden mehrere Mes
124. ator Interface Reference 13 7 System settings This menu provides access to settings that influence the system This menu has the following sub items Date and time Details on page 107 Global settings Details on page 108 Configuration Details on page 110 Macro settings Details on page 117 Date and time You can set the system date and time for the device here Attention If you change the system time the specified time sequence for the measured values yan may no longer match the actual sequence 1 Select System settings gt Date and time The Date and time dialog is displayed Press the list field next to the date A calendar appears Select the day month and year Press the time field to set the system time Press the Timezone list field Select the time zone in which the device is used ou oh Automatic Daylight Saving Time If required activate the option for automatically switching to summer time by pressing this box x Option activated The system automatically switches to summer time 2 Option deactivated The system does not switch to summer time The display of the time changes for all tables and views SHE sartorius 107 cece x mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 108 Global settings This menu has the following sub items View Details on page 108 Global settings Details on page 108 View Numbers after the decimal point
125. be connected via this connection to the evaluation device The use of an external monitor is necessary for devices without touch screens In these cases an external keyboard and a mouse must also be connected PS2 connections keyboard mouse Here the keyboard and or the mouse can be connected for operating the software HE sartorius cece x mechatronics WLM6009 a10081 LMA316PA LMA321PA Product description USB Two connections at the rear 1 connection at the front The USB ports can be used for connecting a printer as well as USB sticks for loading new soft ware versions or for transmitting measurement data A maximum of two USB devices can be operated at the same time The printer must have its own power supply Refer to page 53 to learn more about how to connect USB printers Alternatively to the USB stick a USB hard disk with it s own power supply can be connected O Note USB devices must support USB 1 1 The mouse and keyboard should be preferably attached to the PS2 ports If you connect your keyboard or mouse to a USB port there is no guarantee that the LMA321PA software will recognize these peripherals 2 sartorius ue coe mechatronics WLM6009 a10081 LMA316PA LMA321PA Product description 3 3 16 Scope of delivery The basic scope of delivery for the laboratory version comprises the evaluation device at least one sensor a USB stick for data transfer and for loading software updates the microwa
126. bei ist in der Regel keine Vorbehandlung der Produkte erforderlich d h die Produkte k nnen im naturbelassenen Zustand vermessen werden Es existiert weder ein st render Einfluss der Produktoberfl che K rnung Struktur Farbe usw noch erf hrt das Produkt bei der Messung eine Ver nderung oder Temperaturerh hung Die einmal aufgenommene Kalibrationskurve ist sortenunabh ngig so dass auch Sortenmischungen und Produkte deren Produktionsparameter ver ndert wurden mit einer Kalibrationskurve vermessen werden k nnen Weiterhin spielt der Einsatz von Zuschlagstoffen wie etwa Salzen und Mineralstoffen nur eine untergeordnete Rolle Der auf Basis einer zuvor durchgef hrten Kalibration ermittelte Feuchtewert wird sofort auf dem Display angezeigt Die Software TMV erm glicht bei Bedarf das Speichern der Messwerte Es k nnen beliebig viele unterschiedliche Artikel mit den dazugeh rigen Kalibrationen und Messdaten im Speicher des Ger tes abgelegt werden die Anzahl ist lediglich durch die Speichergr e selbst begrenzt Zur Sicherung der gespeicherten Daten steht eine Backup Funktion zur Verf gung die das Kopieren der Daten auf einen USB Stick bzw externen PC erm glicht Ein Zur ckladen zuvor gesicherter Daten vom USB Stick bzw externen PC auf das Messger t ist ebenfalls m glich SHE sartorius 147 cece 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Produktbeschreibung 3 1 Ger teansicht Vorderseite Display Le T
127. bes the laboratory versions LMA321PA and LMA316PA In this documentation various methods in connection with the measurement of moisture and density are described The installation of the device and the sensors as well as if required the connection of further peripheral devices is dependent on the positioning and requirements of the product to be measured For this reason separate documentation is provided for this Read this documentation before using the instrument The documentation must be stored in the immediate vicinity of the instrument for future reference until the device is disposed of 1 2 Other manuals Please also refer to the special documentation supplied with the sensor s and the technical man ual 1 3 For technical advice on applications e mail pmd300 support sartorius com Phone in Germany 49 0 551 308 3160 Fax in Germany 49 0 551 308 3495 2 sartorius 9 cece 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Before you begin 1 4 oi SEPP O Information on on line help The chapter Operator Interface Reference Details on page 65 contains information about all of the functions corresponding to the menus This information is also available online when oper ating the touch screen Press the help button for information about the active menu item Writing conventions in this documentation In this documentation texts that require special attention are highlighted DANGER
128. bration but a certain standard de viation applies or if there is a constant difference between the value displayed and the actual value laboratory Upper limit Lower limit You can enter limit values here If these values are exceeded by a measurement an alarm event is triggered Memory Specify the amount of memory space to be reserved for results obtained from the product here The number you enter is equivalent to the number of rows in the table of measured val ues The memory value range is dependent on the number of products and calibrations usually around 2000 memory cells are left for measurements Select auto if a product is allowed to make complete use of the entire memory available for the measured values If you are measuring multiple products distribute the memory cells around 2000 amongst the products by entering appropriate values EE sartorius e mechatronics WLM6009 a10081 LMA316PA LMA321PA Calibration 5 6 4 S 5 32 You can select the Overwrite option on a product specific basis If all memory cells assigned to this product have been consumed the oldest values are automatically overwritten without a prompt with the most recent measured values Note If when creating a new product you find that the programme only allows you to set a low value for the memory cells this is because the products which already exist use up all of the available memory If necessary change the mem
129. chaltflachen nutzen Sie z B bei der Bearbeitung einer Tabelle oder wahrend der Einstellung der Produktparameter Je nach Art der Bearbeitung stehen verschiedene Schaltfl chen zur Verf gung Bearbeiten ffnet den entsprechenden Dialog zum Bearbeiten der markierte n Tabellen zeile n Drucken Diese Schaltfl che steht zur Verf gung wenn in einer Tabelle eine oder mehrere Zeilen zum Drucken ausgew hlt sind Hinweise zum Anschluss eines Druckers finden Sie auf Seite 198 L schen Markierte Eintr ge werden gel scht Kopieren Markierte Eintr ge werden kopiert und wieder eingef gt In einigen Tabellen werden Sie nach dem Kopieren aufgefordert die Tabelle zu w hlen in die der Eintrag eingef gt werden soll Bemerkung Zu den markierten Eintr gen wird eine Bemerkung hinzugef gt Statistik F r die markierten Eintr ge wird eine Statistik erstellt Die Statistik kann durch die 1 Anzeige 2 Anzeige Details auf Seite 222 ange zeigt werden au Cie fC Sie k nnen Parameter f r mehrere Werte gleichzeitig bearbeiten Mehrere Wechselt in den Modus zum Bearbeiten mehrerer Werte Al Eintr ge werden mithilfe der folgenden Schaltfl chen ausgew hlt oder einzeln markiert indem Sie auf eine Tabellenzeile dr cken Block 1 Block 2 Markieren Sie durch Dr cken eine Zeile Dr cken Sie diese Schaltfl che um den Anfang eines Blocks zu bestimmen Die Zeile wird gelb hinterlegt angezeigt Die Schaltfl che wi
130. cherheitsgr nden nicht gestattet Das ffnen des Ger tes Abgleich Wartungs und Reparaturarbeiten d rfen nur von einer von uns autorisierten Fachkraft ausgef hrt werden GEFAHR Lebensgefahr durch elektrischen Stromschlag Netzteil Netzfilter und berspannungsschutzmodul sind sicherheitsrelevante Komponenten und d rfen nicht ge ffnet oder repariert werden sartorius 143 mechatronics WLM6009 a10081 LMA316PA LMA321PA Sicherheitshinweise 2 4 A 2 5 2 6 144 Hinweis Der jeweils angegebene Schutzgrad ist nur bei Verwendung von Orginal Steckverbin dungen bzw Verschlusskappen gew hrleistet Installation und Wartung GEFAHR Lebensgefahr durch elektrischen Stromschlag Vor Installations Wartungs oder nderungsarbeiten muss das Ger t von der Versorgungs spannung getrennt werden Schlie en Sie das Ger t an eine ordnungsgem installierte Steckdose an deren Spannung den Technischen Daten entspricht Achten Sie darauf dass die Steckdose gut zug nglich ist damit Sie im Bedarfsfall schnell den Stecker ziehen k nnen Achten Sie darauf dass das Stromkabel nicht durch scharfe Kanten oder hei e Gegenst nde besch digt wird Das Stromkabel darf nicht geknickt oder gequetscht werden Qualifikation des Bedienpersonals Um St rungen und Sch den am Messsystem und in der Produktion zu vermeiden ist der Betrieb dieser Anlage ausschlie lich durch fachgerechtes unterwiesenes Personal durchzuf hren
131. chts des schwarzen Balkens um den dargestellten Ausschnitt zu ver schieben Dies entspricht Seite zur ck oder Seite vor Einstellungen Den Dialog f r die Einstellungen der Grafik erhalten Sie Uber das Men oder indem Sie auf eine der Werte Achsen dr cken Hier legen Sie fest welche Messwerte in welcher Form in der Grafik angezeigt werden X Achse Dr cken Sie auf das Listenfeld Wert W hlen Sie Zeit oder Pos Position Entsprechend werden in der Grafik die Messwerte nach Zeitpunkt oder Position angezeigt auto Dr cken Sie auf das K stchen um die Skalierung der X Achse automatisch anzupassen Dabei wird der gesamte Messverlauf gezeigt Wenn auto deaktiviert ist w hlen Sie in den Eingabefeldern Spanne Tage und Pause Werte f r die gew nschte Darstellung Dr cken Sie auf das Eingabefeld und geben Sie ber den Dialog Zahleneingabe Details auf Seite 268 den jeweiligen Wert ein bei Auswahl Zeit Spanne ist der Gesamtzeitraum der dargestellt wird Der Wert wird im Format hh mm ss Stunden Minuten Sekunden eingegeben Hinweis Anfangs und Endzeitpunkt der Darstellung werden durch die jeweilige Position des Cursors bestimmt Diese Position ver ndern Sie entweder mit den Schaltfl chen zur Navigation Details auf Seite 212 oder indem Sie an eine Stelle der Grafik dr cken Tage entspricht der Anzahl der Tage die dargestellt werden Der unter Spanne gew hlte Wert und der hier gew hlte Wert werden addiert Da
132. chtungstest gt Measure Settings ensity 4 97 Aufrufen des Dialogs Verdichtungstest Eigenschaften Service gt MWTest gt Verdichtungstest gt Dr cken Sie auf die Grafik Grafik gt Einstellungen oder auf das Feld Anzeige 1 Dal vermissen A Compression test 5 TEST GG Tastaturbefehle f r Schaltfl chen in Dialogen bernehmen Eingabe Taste Return oder Enter Abbrechen Esc Taste Aufruf der Online Hilfe F1 gx lt In den Tabellen Produkteinstellungen Sensormodi und MW Ger te k nnen Sie den Dialog zum Bearbeiten der Werte Einstellungen durch Doppelklick auf eine Tabellenzeile aufrufen SHE sartorius 277 mechatronics WLM6009 a10081 LMA316PA LMA321PA Schnellzugriffe Shortcuts 278 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA 15 Glossar Anwendung Mit den Sartorius Feuchtemessgeraten lassen sich die unterschiedlichsten Produkte vermessen Um die Genauigkeit der Messung f r spezielle Anwendungen zu erh hen stehen verschiedene Sensoren zur Verf gung F r den Laboreinsatz und Bypass Systeme rohrf rmige Messzellen und f r den Prozesseinsatz die scheibenf rmigen Planarsensoren Farbunabh ngigkeit Im Gegensatz zu Infrarotmethoden ist die Mikrowellen Resonanztechnik vollst ndig unabh ngig von der Farbe des Produktes Feuchtemesstechnik Die Ger te von Sartorius wurden zur Bestimmung der Materialfeuchte besonders in festen Produkten entwickel
133. ck on Next on the welcome screen The next screen allows you to select a folder in which to install the software m Ommy Setup Choose Install Location Choose Folder in whic Setup will install TMY in the Following Folder To install in a different Folder click Browse and select Wi another Folder Click Next to continue WR Wm ve L i See e Space required 19 6MB e Space available 96 2GB es H lt Back Next gt I Cancel Destination Folder The installer defaults to C Programs TMV Click on Browse to change the path to another folder or drive to be used as the program root Instead of clicking on Browse you can also enter the path straight into the text box Previous version If a previous version of TMV is installed on the PC the installer will default to the root folder of this previous version Installing the update will overwrite the older version see Software updates Details on page 19 Memory The information underneath the text box panel tells you how much space will be required to install the software and how much space is available on the currently chosen drive Should you find that there is not enough space left click on Browse to choose another drive or remove files you no longer need from the chosen drive before you start installing Click on Next when you are done Choose a program folder to place the program link in You can later click on this link to run TMV
134. cken Sie auf Schlie en um zur Anzeige zur ckzukehren Kopieren Sie k nnen ausgew hlte Eintr ge kopieren Kopierte Eintr ge werden entweder zu den Kalibrationsdaten eines Produktes oder zu den Einstellungen f r den Verdichtungstest kopiert Nachdem Sie auf Kopieren gedr ckt haben stehen entsprechende Schaltfl chen zur Verf gung Lesen Sie dazu Schaltfl chen Messung Kalibration Details auf Seite 210 Markieren Sie entweder einen Eintrag einen Block oder alle Eintr ge Um mehrere Zeilen zu markieren dr cken Sie auf die Schaltfl che Mehrere W hlen Sie nun mithilfe der Schaltfl che Block 1 Block 2 mehrere Werte aus oder markieren Sie einzelne Eintr ge Dr cken Sie auf Kopieren W hlen Sie im Dialog Kopieren nach ein Produkt W hlen Sie ob die markierten Werte in die Kalibration des Produktes oder zum Verdichtungs test kopiert werden sollen Dr cken Sie auf Schlie en um zur Anzeige zur ckzukehren Einstellungen Sie erhalten den Dialog Einstellungen Die Darstellung der Tabelle zur Anzeige der Messwerte kann hier individuell angepasst werden Lesen Sie hierzu Einstellungen f r Tabellen Details auf Seite 269 Drucken Ausgew hlte Messwerte k nnen ausgedruckt werden Hinweise zum Anschluss eines Druckers finden Sie auf Seite 198 W hlen Sie im Men Messung gt Tabelle gt Drucken Die Tabelle wird nun im Modus zum Drucken angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen
135. correct reference values or entries Individual values can be deleted from the calibration You can also remove individual points from the calibration These values are not deleted but are not taken into account for the calculation You can select a non linear curve rather than a linear one this curve can have up to 4 segments This enables the even more precise modification of the calibration curve in line with product specific behaviour More calibration measurements may be required depending on the complexity of the curve Note We recommend that you first remove values from the calibration and only delete them once you have generated a satisfactory calibration curve Excluding values from the calibration In the menu select Calibration gt Moisture Density calibration gt Table gt Edit gt Values gt Type The table is now displayed in edit mode i e controls gt page 70 for selecting one or more rows are displayed at the bottom Press the row containing the unsuitable value The value is selected Press Type The Type dialog appears Deactivate the Valid setting and press Apply The value is now displayed in brackets in the Type column of the table and is no longer used for the calculation Press Close The editing process is complete Deleting a value In the menu select Calibration gt Moisture Density calibration gt Table gt Edit gt Delete The table is now displayed in delete mode i e t
136. cted in accordance with the settings for Type gt page 86 gt with different symbols Calibration points that are not used for calculating the curve are greyed out O Note Calibration measurements can be made whilst the graph is displayed The input dialogs for remarks and reference values are displayed automatically 2 Press on the Calibration Moisture operation mode or the graphic icon to dis play the table instead of the graph Zoom 1 Enter a value into the Zoom box or click the arrow buttons to zoom in or out of the graph 2 Click the Zoom in or Zoom out control to change the zoom factor by 5 with each click Q 3 Once you have zoomed in on the graph you can move the graphical display by clicking the graphic and moving it by dragging it with the mouse button held down el 4 If no graph is displayed due to the settings choose auto in Graphic gt Settings Temp correction of temperature If a temperature correction has been set for the calibration page 100 a slider control and an input field labelled Temp are shown above the graphic 1 You can now manually change the temperature correction values here in one of the following ways Moving the slide control Manually entering a value Pressing the arrow fields The curves delimiting the correction range are moved on the chart 98 SEE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Graphic gt Se
137. ctly on the measuring device see page 21 Click on Connect HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Control via external PC Control via network PC Connect the PC and the device to an existing IP network using network cables If not already noted find out the IP address of the measuring device see Determining the IP address of the measuring device Details on page 21 Note When incorporating the device into an already existing network it is not always possible to use the factory set standard IP address see also Changing the IP address of the measuring device Details on page 21 Install TMV on the PC see page 17 Run TMV on the PC Click on the button with the house icon and choose System Settings gt Configuration gt Com munication gt MW Devices Create a new device entry by choosing System Settings gt Configuration gt Communication gt MW Devices gt Edit gt New Choose the type MW4xxx Choose the interface TCP IP Enter the IP address of the measuring device Click on Connect Controlling several measuring devices by one PC If you intend to control several measuring devices via one PC you need to create a respective entry for each device These measuring devices are to be allocated different IP addresses see Changing the IP address of the measuring device Details on page 21 You can then run the TMV software several times connecting it to a different mea
138. d for Black Line sensors not required for older types of sensors o O Ox 110 230 V AC O power cable O T I I 5 S a T E Meyboard Pt 100 temperature sensor Attention When connecting the microwave cables note the colour markings Connect the con nections marked in green MW Gen on both devices to each other using the correspondingly marked cable Use the other cable to connect the connections marked MW Det Use the cable marked in green to connect the MW Gen 1 connection of the LMA321PA to the Gen connection of the sensor Use the second microwave cable to connect the MW Det 1 connection of the LMA321PA to the Det connection of the sensor Link the Sensor 1 connection of both devices using the data cable provided Connect the supplied keyboard with the PS2 connection marked with the keyboard symbol Connect the Pt 100 temperature sensor with the socket marked with the thermometer symbol Observe the information on page 25 Now establish any other optional connections required for other devices such as a monitor mouse or keyboard see the overview on the next page Plug the power cable into the LMA316PA LMA321PA and then into the power outlet EE sartorius a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Startup Connection diagram Possible options LMA316P
139. d in die Kalibration bernommen werden Zeitdauer die nach Erscheinen der Meldung Bitte leeren bis zur Leermessung zur Verf gung steht um das Produkt zu entnehmen bzw einen leeren Messbecher einzusetzen Maximum filling time sec Zeitdauer die nach Erscheinen der Meldung Bitte f llen bis zur Messung zur Verf gung steht um den Sensor zu bef llen Maximum measurement time sec Temperature measurement pause sec Zeitdauer die nach der Messung zum Speichern des Mes sergebnisses zur Verf gung steht Zeitspanne f r das Einf hren des Temperatursensors Pt 100 in die Probe Bei Verwendung von IR Sensoren ist keine Pause notwendig d h der Wert kann auf No gesetzt werden Wait for stable temperature sec HE sartorius seg mechatronics Maximale Zeit die das System wartet ob bei der Tempera turmessung die unter Globale Einstellungen Temperatur festgelegten Stabilitatskriterien erf llt sind Seite 250 261 WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz 13 8 262 Service MW Test MTask Test Hinweis Diese Einstellungen werden von Service Ingenieuren durchgef hrt Verdichtungs Test Hinweis F r diese Einstellungen m ssen Sie Zugriffsrechte ab der Ebene 5 besitzen Bitte lesen dazu im Handbuch das Kapitel Verdichtungs Test Produktauswahl Den Dialog zur Produktauswahl erhalten Sie ber das Men oder indem Sie auf den Produkt namen dr cken
140. d in the current context remain inactive The Apply button only becomes active once an entry has been made VG e Ifyou are working with a keyboard you can also enter characters using the keyboard in question Delete button The character before the cursor is deleted 124 EE sartorius H 0 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference O Note The cursor in the input field can be repositioned by pressing the screen in the required place If you are working with a keyboard you can move the cursor using the arrow keys Shift button 2 This button toggles the keyboard to enable the entry of lowercase letters and numbers e Caps lock button This button toggles the keyboard to enable the entry of uppercase letters and special characters This function remains active until the button is pressed again when the keyboard returns to lowercase letters Numerical input This dialog is displayed when you need to enter numbers numerical values O Note If the virtual keyboard is deactivated in System settings gt Global settings gt Settings 2 only an input field is displayed You can enter values using a USB keyboard or the keyboard of an external PC Reference moisture 7 8 9 4 5 6 Del 1 2 3 EE 0 2 x Cancel Controls for entries which are not relevant or not allowed in the current context remain inactive The Apply button only becomes active once a numbe
141. dass der Messbecher mit dem Sie das Produkt messen in leerem Zustand im Sensor platziert ist Es wird unterschieden zwischen dem weichen und dem harten Leerabgleich Bei einem harten Leerabgleich wird der vom System angenommene Leerpunkt durch den aktuellen Zustand des Sensors neu definiert Mit einem weichen Leerabgleich teilen Sie dem Ger t lediglich mit dass der Sensor im Moment nicht bef llt ist Messungen basieren jedoch weiterhin auf dem Leerzu stand der durch den letzten harten Leerabgleich definiert wurde SHE sartorius 279 seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA Glossar 280 Materialfeuchte Absoluter Gehalt des Wassers in einem Material Im Gegensatz dazu stehen relative Werte z B bei der Bestimmung der Luftfeuchte welche temperaturabh ngig angegeben wird Messzelle siehe Sensor Mikrowellen Resonanzverfahren Feuchtemessmethode welche auf der Messung zweier mit der Feuchte und Dichte korrellierter unabh ngiger Parameter der Verschiebung einer Resonanzfrequenz und der D mpfung des Resonanzpeaks basiert Dazu wird ein mit Wasser beaufschlagtes Produkt in ein Resonanzfeld gebracht Das Wasser beeinflusst das Feld und die Feld nderungen werden gemessen und speziell mathematisch aufbereitet Oberfl cheneffekte Die Mikrowellen Resonanzmethode ist unabh ngig von der Struktur Farbe und der K rnung der Oberfl che des Produktes Wichtig ist dass das Produkt das Messfeld gleichm ig
142. dem externen PC erteilt werden Service Schnittstelle Schraubenschl ssel Symbol RS232 Schnittstelle nur zu Service Zwecken Anschluss f r Service Laptop in St rungsf llen COM1 Passive Meldeschnittstelle Monitor Wird ein externer Monitor verwendet ist dieser ber diesen Anschluss mit der Auswerteeinheit zu verbinden Die Verwendung eines externen Monitors ist vor allem bei Ger ten notwendig die ohne Touchscreen geliefert werden In diesen F llen m ssen auch eine externe Tastatur und Maus angeschlossen werden HE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Produktbeschreibung PS2 Anschl sse Tastatur Maus Hier k nnen zur Bedienung der Software Tastatur und oder Maus an der Auswerteeinheit ange schlossen werden USB Zwei Anschl sse auf der R ckseite 1 Anschluss auf der Vorderseite ber USB kann sowohl ein Drucker angeschlossen werden als auch USB Sticks zum Aufspielen neuer Software Versionen oder zum bertragen von Messdaten Es k nnen maximal zwei USB Ger te gleichzeitig betrieben werden Der Drucker muss ber eine eigene Stromversorgung verf gen Weitere Hinweise zum Anschluss von USB Druckern finden Sie auf Seite 198 Alternativ zum USB Stick kann auch eine USB Festplatte mit eigener Stromversorgung ange schlossen werden O Hinweis Voraussetzung f r USB Ger te ist USB 1 1 F r Maus und Tastatur sollten die daf r vorge
143. den Dialog zur Zahleneingabe Details auf Seite 268 Werte die au erhalb des hier festgelegten Bereichs liegen werden nicht angezeigt Falls dies f r mehrere Werte nacheinander zutrifft sehen Sie gegebenenfalls die Kurve berhaupt nicht Direkt in der Grafik k nnen Sie die vertikale Skalierung nicht ndern Linie Hier wird die Farbe der gew hlten Messkurve gezeigt Die Farbe ist nicht ver nderbar Feuchte blau Dichte gelb Temperatur gr n Alarm W hlen Sie hier ob der Bereich f r den die jeweiligen Messwerte als akzeptabel gelten sollen angezeigt wird Der gew hlte Bereich wird sowohl in der Grafik als auch in der analogen Anzeige gt Seite 208 dargestellt Messwerte die au erhalb dieses Bereichs liegen erzeugen ein Alarmereignis das gegebenfalls an anderer Stelle ausgewertet werden kann z B Produktionssteuerung zeigen Dr cken Sie auf das K stchen um den entsprechenden Bereich anzuzeigen Es wird kein Alarmbereich festgelegt Min Max Hier werden die Werte f r Ober und Untergrenze des Alarmbereichs angezeigt Die Werte werden bei den Produkteigenschaften Seite 244 festgelegt Dr cken Sie auf bernehmen Die Grafik wird entsprechend den gew hlten Einstellungen an gezeigt Drucken Die grafische Darstellung der Messwerte kann ausgedruckt werden HE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz Hinweise zum Anschluss eines
144. den und zu markieren Lesen Sie dazu den Abschnitt Navigation Details auf Seite 212 Wertanzeige Der gemessene Wert wird gro dargestellt Der Wert ist klar erkennbar auch wenn der Benutzer nicht direkt am Ger t arbeitet Eine Navigation ist hier nicht m glich bei Betriebsart Kalibration Auf der Anzeigeflache wird die Tabelle mit den Werten der Kalibration angezeigt Werte k nnen eingegeben erg nzt bearbeitet und gel scht werden Die grafische Darstellung der Kalibration veranschaulicht die Kalibrationskurve erlaubt aber keine direkte Bearbeitung der Werte SHE sartorius 207 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz Statuszeile Messgerat Stopp Angezeigt wird hier der Staus des Ger tes bzw des Sensors z B Sensor leer oder Messger t Stopp wenn eine Aktion des Benutzers erforderlich ist die entsprechende Aufforderung z B Bitte f llen Fehlermeldungen Details auf Seite 271 bei laufender Messung der aktuell gemessene Wert 1 Dr cken Sie bei Ger ten mit Touchscreen auf die Anzeige um jederzeit die Ansicht Messung anzuzeigen O Hinweis Ein Benutzer der lediglich Messungen durchf hrt folgt den hier angezeigten Auforde rungen O Hinweis Einige Ger te die bei der Prozessmessung eingesetzt werden verf gen nur ber ein Display auf dem entweder gemessene Werte oder gegebenenfalls ein Fehlercode angezeigt wird Anzeige 1 2
145. dene Feuchten repr sentieren in einem Punkt m glichst dem Nullpunkt schneiden und wenn ausreichend Messsignale ca 3 20 MHz Frequenzverschiebung zur Verf gung stehen Bei sog Multiplex Ger ten mit 2 angeschlossenen Sensoren werden die Modi beider Sensoren eingelesen d h die Anzahl der zur Verf gung stehenden Sensormodi erh ht sich Hinweis Diese eingelesenen Sensormodi k nnen nicht bearbeitet oder gel scht werden Wurden die Sensormodi nicht beim Starten automatisch eingelesen k nnen Sie dies ber den Befehl Systemeinstellungen gt Konfiguration gt Sensormodi gt Einlesen nachtr glich durch f hren EE sartorius a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Weitere Funktionen EI B Bibliothek Sensormodi bearbeiten Voraussetzungen Sie sind mit Zugriffsrechten der Stufe 4 oder 5 angemeldet Die Bearbeitung von Sensormodi ist im Wesentlichen nur in zwei F llen notwendig Sie arbeiten mit einem lteren Sensortyp oder der Sensor ist aus anderen Gr nden nicht ber ein Datenkabel mit dem Anschluss Sensor 1 2 des LMA3xxPA PMD3xxPA verbunden so dass die Sensormodi nicht automatisch erkannt werden k nnen In diesem Fall m ssen Sie die Sen sormodi manuell auf Basis des Datenblatts dieser Sensoren neu anlegen W hlen Sie den Befehl Systemeinstellungen gt Konfiguration gt Sensormodi gt Bearbeiten gt Neu und tragen Sie die Daten aus dem Datenblatt im Dialog Sensormodu
146. dentifies the product Remark If required enter a remark which might help you to identify the product later on Sensor mode Select the sensor and the associated mode for measuring the product here The device auto matically detects the sensor modes of most properly connected sensors HE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference O Note If a sensor has several resonance modes the following rules apply Dry product low frequency Low density low frequency High moisture high frequency High density high frequency Moisture Density e Moisture offset Density offset An offset is entered if a reference to the calibration of a similar product is used or if the same difference is always found between the displayed value and the actual laboratory value O Example You enter an offset of 1 If with the original calibration a measured value of 10 would be displayed here 11 is displayed with the referenced calculation Upper lower limit Use this entry to specify the limits which trigger an alarm if exceeded by the measured values If the box is not selected measurements outside the range do not trigger an alarm MW type The specifications here serve only to provide information if issues arise You cannot edit them Measurement gt Mean You use this entry to specify the number of results needed to calculate the mean value of each measuring cycl
147. der Dropdown Liste Master aus Andere Einstellungen sind nur f r den Service relevant Ein Gateway muss nur angeben werden wenn Ihr PC und das Ger t nicht direkt im selben Netzwerk sind Fragen Sie dazu gegebenenfalls ihren Netzwerkadministrator MW Ger t Wenn das Ger t direkt mit einem PC verbunden ist k nnen Sie ber diese Funktion die IP Adresse des Ger ts neu setzen Dies ist nur notwendig wenn die IP Adresse nicht direkt am Ger t selber ge ndert werden kann und das Ger t unter einer anderen Adresse in ein IP Netz werk eingebunden werden soll Nach dem ndern der IP Adresse muss das Ger t neu gestartet werden damit die nderung wirksam wird 256 SEE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz MW Gerat Die Einstellungen in diesem Bereich zeigen die Systemkonfiguration Ihres Messgerats Die Systemkonfiguration darf nur von Sartorius bearbeitet werden und steht Benutzern mit Zugriffs rechten ab Stufe 5 zur Ansicht zur Verf gung Druckerkonfiguration O Hinweis F r diese Einstellungen m ssen Sie mit Zugriffsrechten mindestens der Stufe 4 angemeldet sein Bevor Sie am Messger t den Befehl Drucken nutzen m ssen Sie einen Drucker anschlie en und mithilfe der Druckerkonfiguration einrichten Hierbei kann es sich um einen im Netzwerk verf gbaren Drucker handeln oder bei Laborger ten auch um einen direkt angeschlossenen USB Drucker Bei Messger ten die ber
148. der Tabelle wird um einen Eintrag vor gebl ttert Die Anzeige der Tabelle wird um eine Seite 10 Eintr ge vor gebl ttert Der Cursor steht in der untersten sichtbaren Zeile Springt zum letzten Eintrag der Tabelle bzw springt zum letzten Wert der grafi schen Darstellung Die Schaltfl che bleibt gedr ckt das hei t blau hinterlegt Die anderen Naviga tions Schaltfl chen k nnen nun nicht gedr ckt werden Aktuell ermittelte Werte werden kontinuierlich als zuletzt ermittelter Wert ange zeigt Der Cursor steht in der untersten sichtbaren Zeile Dr cken Sie die Taste ein zweites Mal um die kontinuierliche Anzeige des zuletzt ermittelten Wertes wieder zu beenden Y VI lt AA Navigation und Cursorposition Die Navigations Schaltflachen setzen jeweils den Cursor an eine neue Position Es werden dabei keine Werte markiert oder ausgew hlt Navigation und Tabellensortierung Anfang und Ende in einer Tabelle werden durch die Sortierung bestimmt Bei aufsteigender Sortierung Sortierpfeil zeigt nach oben entspricht der Tabellenanfang dem kleinsten Wert in der Spalte nach der sortiert ist Bei absteigender Sortierung entspricht der Anfang der Tabelle dementsprechend dem gr ten Wert HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz Ansicht Hilfe Ge Zeigt die Hilfe Chronik D Wenn das Men nicht ge ffnet ist wird die Schaltfl che Chronik eingeblendet Chronik Dr c
149. det sein Das Einrichten eines Druckers erfolgt ber den Men befehl Systemeinstellungen gt Konfigura tion gt Druckerkonfig Seite 257 Hinweise zum Drucken direkt vom Messger t Das Messger t arbeitet mit dem unter LINUX gebr uchlichen Drucksystem CUPS Wenn Sie Daten drucken erhalten Sie in TMV einen Druckdialog wie Sie ihn auch von der Arbeit vom PC her kennen Dieser Dialog sieht abh ngig vom gew hlten Drucker unterschiedlich aus Sartorius liefert Druckertreiber f r diverse Standarddrucker aus Sollte f r Ihren Drucker kein pas sender Treiber vorhanden sein wenden Sie sich bitte an Sartorius Einrichten eines Netzwerk Druckers Voraussetzungen Sie sind mit Zugriffsrechten der Stufe 4 oder 5 angemeldet Der Drucker ist im Netzwerk eingerichtet Das Messger t ist mit dem IP Netzwerk verbunden W hlen Sie den Men befehl Systemeinstellungen gt Konfiguration gt Druckerkonfig Sie er halten den Dialog Printer Configuration HE sartorius coe mechatronics WLM6009 a10081 LMA316PA LMA321PA Weitere Funktionen Printer Configuration Administration Printer Device Make Model Driver Printer Options Printer May contain any printable characters except and space Version 0 1 4 HP_LaserJet HP LaserJet Series PCL 4 5 CUPS v1 2 Add New Printer Modify Printer HP_LaserJet Set Printer Options HP_LaserJet Set As Default HP_LaserJet Print Test Page
150. ding values are available for the samples As a rule the temperature should be taken into account in the case of temperature variations of more than 5 C Press Apply to accept the setting and calculate the calibration Once the calibration has been successfully calculated the parameters are displayed in the 1st 2nd display panel See 1st display 2nd display PA Press Expert to make all settings manually Press auto to have the calibration curve calculated automatically using the selected settings Expert You can specify the calibration settings manually here Settings made beforehand linear non linear number of segments are applied but can be changed here You can set the limits of the individual segments of the calibration curve You can modify the correction value manually If you activate this option for temperature or mois ture you can use the slider control or number input function in the graphical depiction of the cali bration curve to set the correction value Results The right hand side of the dialog shows the results of the settings made These fields cannot be edited If the calibration cannot be calculated using these parameters a message to this effect is displayed in red at the bottom of the Results panel Press Calibrations to display a list of all possible calibrations This list is displayed in the same dialog on the second Calibrations tab GC The list of calibrations can be filtered to improve cl
151. display one or two curves with a choice of moisture density and temperature You can make these settings and more by choosing Measurement gt Graph gt Settings Details on page 78 To start or stop the measurement process and to take samples and carry out an empty sensor adjustment use the controls described in Measurement Calibration Details on page 70 Determining the cursor position The values of the measurement at the cursor position can be displayed in one of the display panels Display panel 1 2 Measurement Details on page 68 Press the graph The cursor is fixed to this position When you switch to the table display page 74 the cursor position is retained Use the controls described in Navigation Details on page 72 to set the cursor to a particular position or to display further values in the measurement series Note Press the Goto last control once The control remains activated and therefore has a blue background The cursor now remains at the position of the last current measurement The graph is constantly refreshed Press the Measurement mode display or the graph symbol to switch to the readings display Use the Zoom in and Zoom out controls to reveal more zoom in or less zoom out details in the graph The zoomed in view displays the curve with the cursor at the centre of the visible X axis If you move the cursor to a new position by pressing the graph the display of the current section is mov
152. dus zum L schen angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen Seite 210 zum Markieren einer oder mehrerer Zeilen Dr cken Sie auf eine Zeile Der Wert ist markiert Dr cken Sie auf L schen Der markierte Wert wird gel scht Der Wert wird weiter ber cksichtigt solange bis die Kalibrati onskurve neu berechnet wird Dr cken Sie auf Schlie en Der L sch Modus ist beendet Hinweis Sie k nnen einzelne Kalibrationspunkte aus der Kalibration entfernen ohne diese zu l schen Dazu weisen Sie dem Punkt unter Typ die Eigenschaft nicht g ltig zu 2 Seite 227 Dieser Wert wird f r die Kalibration nicht ber cksichtigt Hinweis Sie k nnen bei einer guten Kalibration die Sie bereits gespeichert haben alle Einzel werte l schen um Speicherplatz im Ger t freizugeben Die Kalibration bleibt erhalten Kopieren Einzelne Werte der Kalibration k nnen kopiert werden W hlen Sie im Men Kalibration gt Dichte Kalibration gt Tabelle gt Bearbeiten gt Kopieren Die Tabelle wird nun im Modus zum Kopieren angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen Seite 210 zum Markieren einer oder mehrerer Zeilen Kopierte Eintr ge werden wahlweise zu den Kalibrationsdaten eines Produktes oder zu den Einstellungen f r den Verdichtungstest kopiert Markieren Sie entweder einen Eintrag einen Block oder alle Eintr ge Um mehrere Zeilen zu markieren dr cken Sie auf die Schaltfl che Mehrere
153. e Memory Specify the amount of memory space to be reserved for results obtained from the product The number you enter is approximately equivalent to the number of rows in the table of measured values Select auto if a product is allowed to make complete use of the entire memory available for the measured values If you create several products share out the memory cells around 2000 amongst them accord ingly If the set memory capacity is no longer available the system automatically sets the highest possible value If necessary you can deduct the value required from other products You can select the Overwrite option on a product specific basis If all memory cells assigned to this product have been consumed the oldest values are automatically overwritten without a prompt with the most recent measured values If the option is not enabled there will be no further measuring until you manually delete at least some of the entries O Note If when creating a new product you find that the program only allows you to set a low value for the memory cells this is because the products which already exist use up all of the available memory If necessary change the memory settings for the existing products to free memory cells for the new product e AB Linearization A offset B offset These specifications serve only to provide information if issues arise and should not be edited 4 Press Apply VG The product has now been created O Note T
154. e gt Export Details on page 89 O Note Ifthe table contains more than 10 values use the navigation controls See Navigation Details on page 72 Table gt Edit Values The reference values for the measured samples are entered into the calibration table here 1 Inthe menu select Calibration gt Moisture calibration gt Table gt Edit gt Values Inthe submenu select whether an individual entry Remark Reference moisture Type etc or all values are to be edited Remark Details on page 86 Reference moisture Details on page 86 Type Details on page 86 All values Details on page 87 The table is now displayed in edit mode i e the controls for selecting one or more rows page 70 are displayed at the bottom 1 Press a row to select it EE sartorius SS seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference rE J 2 86 Press the control to start editing If you selected the option for entering a single value reference moisture reference density etc the corresponding Numerical input Details on page 125 or Text input Details on page 124 dialog is displayed If you selected the option for entering the type the Type gt page 86 dialog is displayed If you selected the option for entering all values the Calibration properties gt page 88 dialog is displayed Note You can also press the relevant field in a table entry to en
155. e Bemerkung erstellt 2 Um mehrere Zeilen zu markieren dr cken Sie auf die Schaltfl che Mehrere W hlen Sie nun mithilfe der Schaltfl che Block 1 Block 2 mehrere Werte aus oder markieren Sie einzelne Eintr ge Dr cken Sie auf Bemerkung Sie sehen den Dialog zur Texteingabe Details auf Seite 267 Hier geben Sie den Text ein der zusammen mit dem Wert angezeigt und gespeichert wird Bereits bestehende Bemerkungen werden dabei berschrieben 5 Dr cken Sie auf Schlie en um zur Anzeige zur ckzukehren O Hinweis Dr cken Sie auf eine Zeile in der Tabelle um ebenfalls das Eingabefeld f r eine Bemerkung f r den jeweiligen Wert zu erhalten SHE sartorius 215 cece mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz Lo 216 L schen Sie k nnen ausgew hlte Eintr ge in der Tabelle l schen Achtung Nachdem Sie auf L schen gedr ckt haben stehen entsprechende Schalt fl chen zur Verf gung Lesen Sie dazu Schaltfl chen Messung Kalibration Details auf Seite 210 Gel schte Messwerte sind in der Anzeige nicht wieder darstellbar Markieren Sie entweder einen Eintrag einen Block oder alle Eintr ge Um mehrere Zeilen zu markieren dr cken Sie auf die Schaltfl che Mehrere W hlen Sie nun mithilfe der Schaltfl che Block 1 Block 2 mehrere Werte aus oder markieren Sie einzelne Eintr ge Dr cken Sie auf L schen Markierte Eintr ge werden gel scht Dr
156. e Messung Markierte Eintr ge sind im Gegensatz zur Cursurposition dunkel hinterlegt 4 2007 02 16 09 55 24 BEMERKUNG 4 862 453 5 2007 02 16 09 55 27 BEMERKUNG 5 8 70 4 50 2007 02 16 09 57 04 BEMERKUNG 6 200 7 02 16 Op BEMERKUNG 7 007 02 16 09 57 07 BEMERKUNG 8 a 2007 02 16 09 57 09 BEMERKUNG 9 8 64 AER 10 2007 02 16 09 57 10 BEMERKUNG 10 8 62 451 11 2007 02 16 09 57 12 BEMERKUNG 11 8 61 452 12 2007 02 16 09 57 13 BEMERKUNG 12 8 70 4 56 13 2007 02 16 09 57 15 BEMERKUNG 13 8 69 456 Tabelle Grafik Wertanzeige bei Betriebsart Messung Auf der Anzeigefl che werden die Ergebnisse der Messung dargestellt Die Anzeigeart w hlen Sie im Men punkt Messung Tabelle Gemessene Werte werden in einer Tabelle dargestellt Sie k nnen die Tabelle nach einzelnen Spalten sortieren Sie k nnen Spalten individuell anordnen oder ausblenden Lesen Sie dazu den Abschnitt Tabelle Details auf Seite 214 e Grafik Gemessene Werte werden als Verlaufskurve dargestellt Tendenzen oder Ausrei er sind so leicht erkennbar Zus tzlich kann der Wertebereich dargestellt werden in dem die Feuchte bzw die Dichte des Produktes als bedenklich erkannt werden soll und dementsprechend ein Alarmer eignis generiert wird Lesen Sie dazu den Abschnitt Grafik Details auf Seite 218 Unabh ngig von der gew hlten Darstellung helfen Ihnen die Befehlschaltfl chen f r die Naviga tion Werte zu fin
157. e auf Set Printer Options lt Name gt Das Register Printer Options wird ange zeigt Printer Configuration Administration Printer Device Make Model Driver Printer Options Printer Version 0 1 4 HP_LaserJet PageSize Ad e InputSlot Default e Resolution 300dpi e Duplex None e Option False e Set Printer Options HP_LaserJet 4 gt UK Le A a L Ges JL me Nehmen Sie die gew nschten nderungen vor Ge nderte Einstellungen die noch nicht ber nommen wurden werden rot dargestellt Dr cken Sie abschlie end auf Set Printer Options um die ge nderten Einstellungen zu ber nehmen Sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Weitere Funktionen 12 4 Referenzstandard Diese Funktion dient dazu die technische Funktion von Sensor und Messger t zu berpr fen Optional k nnen Sie f r Ihren Sensor einen Referenzk rper erwerben Dieser Referenzk rper ist auf den jeweiligen Sensor abgestimmt und darf nur zusammen mit dem Sensor benutzt werden f r den er geliefert wird Zusammen mit dem Referenzk rper erhalten Sie ein Zertifikat in dem die Werte f r diesen Referenzk rper aufgelistet sind Referenzstandard ber TMV 1 Stoppen Sie ggf den laufenden Prozess sodass der Sensor leer ist Der Sensor muss frei von Produktr ckst nden sein 2 W hlen Sie das Produkt REFERENCE 3 F hren Sie einen Leerabgleich durch Bef llen Sie den Sen
158. e automati cally recalculated where applicable At least two calibration readings and the corresponding reference values are required to calculate a Calibration 1 Press the Calibration display panel to change the calibration settings See section Type set tings Details on page 91 68 2 sartorius coe mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Mode The current process is displayed here Measurement Details on page 73 Calibration Details on page 84 In addition the system displays information telling you whether the calibration is for moisture or density Pressing the panel toggles the display screen between the table and graph view Product settings Details on page 103 Compression test Details on page 119 Sensor modes Details on page 110 MW devices Details on page 112 Product Displays the product that is being measured or calibrated The selected moisture offset for the calibration is displayed to the right 1 To select another product press the display screen The Product choice Details on page 73 dialog appears The product selection screen can be called up using the Measurement Details on page 73 or Calibration Details on page 84 menu item 2 Press on the moisture offset display to enter a different value for the moisture offset EE sartorius cece 3 mechatronics WLM6009 a10081 13 3 70 Controls LMA316PA LMA321P
159. e calibration Note If you have a previous calibration that you are satisfied with you can delete the individual values to free up memory space The actual calibration is retained Copy Individual calibration values can be copied In the menu select Calibration gt Moisture calibration gt Table gt Edit gt Copy The table is now displayed in copy mode i e the controls page 70 for selecting one or more rows are displayed at the bottom Copied entries are pasted to the calibration data of a product or to the settings for the density test as selected Select an entry a block or all entries To select several rows press Multi Now select several values using the Block 1 Block 2 control or select entries individually Press Copy Select a product from the Copy to dialog Specify whether the selected values are to be copied to the calibration ofthe product orthe com pression test ERE sartorius mY mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference x 5 88 Only the measured values are copied not the reference values Press Close The copy process is complete New The Calibration properties dialog appears You create a new entry in the calibration table independently of the measured values Every value can be entered via this dialog Press an input field to display the Numerical input Details on page 125 or Text input Details on page 124 dialog Press Apply t
160. e curve maximum found Use the Start Sweep function choose Service gt MW test gt MTask test gt Res Curve to see whether there is a resonance curve between the start and stop frequencies 2 0 9 Incorrect selection of sensor mode or hardware error Use the Start Sweep function choose Service gt MW test gt MTask test gt Res Curve to see whether a resonance curve appears for Backgr Fr 2 0 10 PLL error Hardware error 3 0 0 Missing empty sensor adjust or MW sensor temperature Perform an empty sensor adjust page 70 If you activated the Temperature coefficients option in the Sensor modes dialog you must connect a sensor which returns temperature values The Sensor modes dialog is called by choosing System settings gt Confi guration gt Sensor modes gt Edit gt Values see additional information on pages 50 and 110 2 sartorius 129 coe mechatronics WLM6009 a10081 130 LMA316PA LMA321PA Operator Interface Reference Error code Cause and corrective action 4 x40 0 Measured values out of permitted range Perform a hard empty sensor adjust gt page 70 In the compression test properties check the parameters in Measurement range MR Mhz x 9 Parameter A min too high x 10 Parameter A max too low x 11 Parameter B min too high x 12 Parameter B max too low Call up the Compression test properties dialog by choosing Service gt MW test gt Compression
161. e list below indicates actions for remedying errors Error code Cause and corrective action MV RE MT 1 0 0 Sensor empty no measurement possible 2 0 2 The sensor s starting frequency is too high e Specify a lower starting frequency in the Sensor mode dialog choose System settings gt Configuration gt Sensor modes gt Edit gt Values e Alternatively specify a different sensor mode Product settings dialog choose Product settings gt Edit gt Values 2 0 3 The sensor s starting frequency is too low e Specify a higher starting frequency in the Sensor mode dialog choose System settings gt Configuration gt Sensor modes gt Edit gt Values e Alternatively specify a different sensor mode Product settings dialog choose Product settings gt Edit gt Values 2 0 4 Signal too strong Faulty sensor or MW hardware 2 0 5 Signal line loss too high Increase the value of the Max A Dev parameter choose Service gt MW test gt MTask test gt Parameters This reduces the precision of measure ments 2 0 6 ADC deviation too large Increase the value of the Max A Dev parameter choose Service gt MW test gt MTask test gt Parameters This reduces the precision of measure ments 2 0 7 Instable resonance curve Increase the value of the Stability MHz parameter choose Service gt MW test gt MTask test gt Parameters This reduces the precision of measure ments 2 0 8 No resonanc
162. e menu items described here Access depends on your user and its associated rights Measurement Table T Calibration J Product setti Graphii J System settir Readings op Service Q LoginiLogou QLanguages Selected menu items have white background The associated sub menus are displayed in accordance with the selected menu item Depending on your user rights not all of the menu items may be available to you Some entries in the dialogs can be changed only if you have the relevant rights Such values are displayed with a grey background if you cannot edit them The number beneath each menu item and the symbol clarify the corresponding function regard less of the set language In order to call up a command press one of the entries in the menu If applicable a further dialog appears in which you can implement settings Commands such as Print or Delete and commands that change the layout of the display are executed immediately lt 6 If the menu is not open the History control is displayed instead of the Back con History Press Back to hide the top menu level trol Press this control to display recently used menu items and to call them up again if required Press the control a second time to hide the list again Never touch the screen with sharp edged objects such as screwdrivers or ball A point pens etc These might damage the surface Display
163. easurements calibrations and prod uct sensor mode settings which you have made You may therefore wish to back up the current state of the system before running this function If you are controlling the device using an external PC you may have to reassign the IP address since this function resets it to the factory setting of 172 28 1 1 Prerequisites The measuring device is switched on and you are logged in with level 4 access rights or higher see Creating a backup Stop any measurements that are currently in progress Choose Service gt Backup The Backup dialog appears In the top panel select Restore factory settings Press Apply The state stored in the internal backup is restored Replacing fuses DANGER Lethal risk caused by electric shock Before checking and changing the fuses turn off the device and unplug it from the mains Turn off the LMA321PA using the on off switch 1 on the rear of the device and disconnect the mains cable Pull out the insert 4 between the mains connection and the on off switch Check both fuses 2 3 and if necessary replace them with fuses which comply with the technical specifications gt page 63 Push in the insert containing the fuses until it clicks into place You can then reconnect the device to the power supply and switch it back on EE sartorius S mechatronics WLM6009 a10081 LMA316PA LMA321PA Service and maintenance 10 4 AN 10 5 10 6 62
164. echte u el 195 SHE sartorius mechatronics 32 Sartorius mechatronics EG Konformit tserkl rung EC Declaration of Conformity Sartorius AG Weender Landstr 94 108 37075 G ttingen Germany erkl rt dass das Betriebsmittel declares that the equipment Ger t Labor Feuchtemessger t Apparatus Laboratory moisture analyzer Typbezeichnung Type LMA321PA 000U LMA316PA 000U mit den grundlegenden Anforderungen der folgenden Europ ischen Richtlinien bereinstimmt complies with the basic requirements of the following European Directives Richtlinie 2004 108 EG Elektromagnetische Vertr glichkeit Directive 2004 108 EC Flectromagnetic compatibility Richtlinie 2006 95 EG Elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen Directive 2006 95 EC Electrical equipment designed for use within certain voltage limits Das Ger t erf llt die anwendbaren Anforderungen der in Anhang 1 aufgef hrten harmonisierten Europ ischen Normen The apparatus meets the applicable requirements of the harmonized European Standards listed in Annex 1 Jahr der Anbringung des CE Zeichens 10 Year of attachment of CE mark Sartorius AG G ttingen 2010 08 10 2e Be fe AN A Dr Reinhard B aumfalk Dr Dieter Klausgrete Leitung Entwicklung Leitung International Certification Management Mechatronik Mechatronik Vice President R amp D Head of International Certification Management Mechatronics Mechat
165. ect Edit from the Product settings menu The table is now displayed in edit mode i e the controls gt page 70 for selecting one or more rows are displayed at the bottom Protected products are indicated by a lock You cannot alter the calibration of a protected product Values Select Product settings gt Edit gt Values Press a row to select it Note Settings for several products can be selected and edited at the same time This is helpful for instance if several products refer to a common calibration or if the same sensor mode is used by several products If this is the case Multi is displayed in the header line of the Product settings dialog Press the control to start editing The Product properties dialog appears Press an input field The Numerical input Details on page 125 or Text input Details on page 124 dialog appears Products are described in the Product settings gt New Details on page 104 section Note If you assign a new ID number the selected products are given new and unique ID numbers on the basis of the entered number The system automatically increments the number by one in each case Press Apply to accept the changed values Press Close The editing of the values is complete EE sartorius 103 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Set wi 104 Delete You can delete a product from the list However you cannot delete the predefi
166. ed accordingly A bar display above the graph clarifies which section of the overall curve is currently being displayed If an empty rectangle is shown the entire curve for the whole measurement series is displayed sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 78 Press to the left or right of the black bar to move the displayed section this corresponds to Page back or Page forward Settings You reach the dialog for making graph settings from the menu or by pressing the value axis You define the measured values to be displayed here as well as the way in which they are to be shown in the graph X axis Press the Value list field Select Time or Pos position The measured values are displayed in the graph by time or position accordingly auto Press the box to automatically adjust the scale of the X axis All of the readings in the measure ment series are then shown If auto is deactivated select values for the required display format in the Span Days and Pause fields Press the input field and enter the required value using the Numerical input Details on page 125 dialog If Time is selected Span is the overall time period to be depicted Enter the time as hh mm ss hours minutes seconds Note The start and end time points for the depiction are defined by the respective positions of the cursor You change these positions using the controls described in
167. ed accordingly if fluctuating measurement temperatures are detected g Deactivated No temperature correction takes place Increment 1 Enter a temperature correction factor I 2 Click Apply to accept the settings Graphic gt Print The graphical depiction of the calibration can be printed See page 53 for information on how to connect a printer Select Print gt from the Calibration gt Moisture calibration gt Graphic menu The graph is printed as it appears on the screen 90 SEE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Type settings Type settings Here you define the type of calibration Choose from the following Simple Expert auto O Note You can also display this dialog by pressing the 1st display field calibration type correc tions Simple This dialog enables the simple calculation of the calibration 1 From the list field choose either the simple linear calibration type or the non linear calibration type which depending on the available values can consist of up to four segments Linear The calibration curve is a straight line Non linear The calibration curve is not necessarily a straight line Areas of the calibration curve may appear as curves O Note Please note that for a more complex calibration type more measured values are required as would be expected Extremum Inthe case of the non linear calibration type you s
168. efeld inaktiv grau dargestellt Hinweis Die Cursorposition ndern Sie entweder in der Tabelle der Grafik oder indem Sie die Schaltfl chen f r die Navigation Details auf Seite 212 nutzen Der dargestellte Wertebereich wird auf beiden Seiten durch schwarze Markierungen und die Angabe des Wertes verdeutlicht Der gemessene Wert wird in der Mitte der Balkengrafik digital angegeben Die Anzeige erfolgt in vordefinierten Farben Feuchte blau Dichte gelb Temperatur gr n Rote Markierungen stellen den benutzerdefinierten Alarmbereich dar Wenn der dargestellte Wert in den Alarmbereich f llt wird die Balkengrafik rot angezeigt HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz Einstellungen Diesen Dialog erhalten Sie wahlweise ber das Men oder indem Sie auf die Anzeige dr cken Wert 1 Dr cken Sie auf das Listenfeld um die Messwerte auszuw hlen die angezeigt werden 2 W hlen Sie zwischen Feuchte Dichte Temp Temperatur Skalierung Geben Sie hier den kleinsten und den gr ten Wert f r die Skalierung der Darstellung an 1 Dr cken Sie auf ein Eingabefeld und Sie erhalten den Dialog zur Zahleneingabe Details auf Seite 268 Werte die au erhalb dieses Bereichs liegen werden trotzdem digital angezeigt die analoge Balkendarstellung ist in diesem Fall nicht aussagekr ftig Alarm Hier werden die Werte f r Ober und Untergrenze des Al
169. egments of the calibration curve You can modify the correction value manually If you activate this option for temperature or density you can use the slider control or number input function in the graphical depiction of the calibration curve to set the correction value Results The right hand side of the dialog shows the results of the settings made These fields cannot be edited If the calibration cannot be calculated using these parameters a message to this effect is displayed in red at the bottom of the Results panel Press Calibrations to display a list of all possible calibrations This list is displayed in the same dialog on the second Calibrations tab The list of calibrations can be filtered to improve clarity Press the All calibrations list field and select a filter Press an entry to select it Press Choice to apply these parameters for the calibration Press Display to return to the graphical depiction or table view In the graphical depiction or table view press Save to save the calibration or return to the dialog with the expert settings Note If using the program on your PC press Apply to adopt the setting Press Simple to return to a simple calibration process Press List to display the parameters for the chosen calibration in a list auto The calibration is calculated automatically If you want to change the settings for calculating the calibration press the 1st display panel calibration type correct
170. eiten der Druckereinstellungen Grunds tzliche Bedienung Sie rufen den Dialog Printer Configuration ber den Men befehl Systemeinstellungen gt Kon figuration gt Druckerkonfig auf Nach Beenden der Einstellungen schlie en Sie den Dialog durch Dr cken auf Close Drucker aus der Liste entfernen Nicht mehr ben tigte Drucker k nnen aus der Liste der zur Verf gung stehenden Drucker entfernt werden W hlen Sie aus der Liste unter Printer den zu l schenden Drucker aus Dr cken Sie auf Delete Printer lt Name gt Der Drucker wird ohne weitere Abfrage entfernt SHE sartorius 201 mechatronics WLM6009 a10081 202 Drucker als Standarddrucker festlegen LMA316PA LMA321PA Weitere Funktionen Sind mehrere Drucker als m gliche Ausgabeger te angelegt wird der erste Drucker in der Liste als Standarddrucker verwendet Es kann jedoch auch jeder andere in der Liste vorhandene Drucker als Standarddrucker eingestellt werden W hlen Sie aus der Liste unter Printer den gew nschten Drucker aus Dr cken Sie auf Set As Default lt Name gt Damit wird der ausgew hlte Drucker als Standard drucker f r die Ausgabe an diesem Messger t festgelegt Voreinstellungen ndern Sollen die beim Anlegen des Druckers vorgenommenen Voreinstellungen wie Papierformat Auf l sung usw ge ndert werden w hlen Sie aus der Liste unter Printer den Drucker aus dessen Einstellungen bearbeitet werden sollen Dr cken Si
171. elden Klicken Sie nachdem Sie alle Einstellungen vorgenommen haben auf bernehmen Der neue Benutzer wird nun in der Liste angezeigt Klicken Sie im Dialog Benutzerkonfiguration ebenfalls auf bernehmen Hinweise zum Bearbeiten der Benutzereinstellungen Um die Einstellungen f r einen Benutzer zu ndern z B neues Passwort vergeben w hlen Sie im Dialog Benutzerkonfiguration den entsprechenden Eintrag aus und dr cken auf Bear beiten Der Dialog Benutzer bearbeiten wird mit den Einstellungen des ausgew hlten Benut zers ge ffnet und kann wie beim Anlegen eines neuen Benutzers bearbeitet werden Um einen Benutzer aus der Liste zu entfernen w hlen Sie den entsprechenden Eintrag aus und dr cken auf L schen Der Eintrag f r diesen Benutzer wird nach Best tigen einer Sicherheits abfrage gel scht Der Standardbenutzer und der letzte Benutzer der Stufe 5 k nnen nicht gel scht werden Sensormodi Jedem Produkt ist ein Sensormodus zugeordnet Die von einem Sensor unterst tzten Modi werden von Ger ten die ber ein Datenkabel mit der Auswerteeinheit verbunden sind im Normalfall automatisch erkannt so dass Sie beim Anlegen eines Produkts lediglich einen der aufgelisteten Modi ausw hlen m ssen Hier gilt die Regel dass bei mehreren Sensormodi immer zun chst mit Hilfe eines Verdichtungs tests siehe S 169 der optimale Sensormodus ermittelt werden muss Optimal ist wenn sich die Verdichtungslinien die verschie
172. en ebenen und w rmebest ndigen Untergrund EE sartorius a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Sicherheitshinweise Die Oberseite des LMA316PA LMA321PA kann als Abstellfl che f r einen Monitor verwendet werden z B bei Messgeraten die nicht Uber einen integrierten Touchscreen verf gen Max Tragkraft 5 kg Andere Gegenst nde d rfen nicht auf dem LMA316PA LMA321PA abgestellt werden Trennen Sie die Verbindung des Messger tes zu anderen Ger ten bevor Sie es umstellen oder transportieren Ziehen Sie die Stecker auf der R ckseite des Ger tes heraus An der Unterseite des Messger tes befinden sich Ger tef e Da die M bel bzw Bodenober fl chen aus den verschiedensten Materialien bestehen und mit den unterschiedlichsten Pflege mitteln behandelt werden kann es nicht v llig ausgeschlossen werden dass manche dieser Stoffe Bestandteile enthalten die die Ger tef e angreifen und aufweichen Legen Sie ggf eine rutschfeste Unterlage unter die Ger tef e Sicherheitsrelevante Schilder auf den Ger ten Das Typenschld auf der Ger teunterseite der Laborger te enth lt folgenden Warnhinweis WARNING DISCONNECT SUPPLY BEFORE SERVICING Amis ce x Vor der Installation Deinstallation Servicearbeiten oder einer Feuchtreinigung ist das Gerat durch Ziehen des Netzsteckers von der Spannungsversorgung zu trennen Beachten Sie die entsprechenden Sicherheitshinweise und Arbeitsanweisunge
173. en Fenstergr e 4 Dr cken Sie abschlie end auf bernehmen Die Einstellungen sind ab jetzt g ltig Globale Einstellungen In diesem Dialog werden verschiedene allgemeing ltige Einstellungen festgelegt Im oberen Bereich des Dialoges erscheinen mehrere Register MW device Temperatur Analogausg nge Dr cken Sie auf eines der Register um die jeweilige Seite anzuzeigen Wenn Sie Einstellungen ge ndert haben dr cken Sie abschlie end auf bernehmen um den Dialog zu schlie en und die nderungen zu bertragen In einigen F llen muss TMV neu gestartet werden damit die nderungen wirksam werden SHE sartorius 249 cece 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz 250 MW device Prozess Laboratory Mit TMV k nnen sowohl Prozessmessger te als auch Labormessger te gesteuert werden wobei ber die hier vorgenommene Einstellung der Bedienablauf w hrend des Messens unter schieden wird Bei Einstellung Prozess ist TMV f r die kontinuierliche Messung im laufenden Prozess eingerichtet bei Einstellung Laboratory f r Einzel Messungen im Labor Diese passend zum Ger t und dem angeschlossenen Sensor vorkonfigurierte Einstellung darf daher nicht ver ndert werden da sonst das System nicht mehr funktioniert Grunds tzlich w re es aber ber diese Einstellung m glich beispielsweise ein Laborger t mit einem Planarsensor f r die Prozessmessung zu verwenden Autostart nur bei
174. en Sie Anschluss und Funktion des Produkt Temepratursensors 8 0 0 Falls Sie im Dialog Sensormodus die Option Temperaturkoeffizienten aktiviert haben m ssen Sie einen Sensor anschlie en der Temperatur werte liefert 9 0 0 Die f r Feuchtigkeit bzw Dichte ermittelten Werte liegen au erhalb des vorgegebenen Bereiches ndern Sie die Werte entsprechend in den Produkteinstellungen Details auf Seite 244 HE sartorius mechatronics 273 WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz 274 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA 14 Schnellzugriffe Shortcuts Alle Funktionen des Programms k nnen ber das Men aufgerufen werden Fur einige der h ufiger gebrauchten Funktionen stehen zus tzlich direkte Zugriffsm glichkeiten zur Verf gung sog Schnellzugriffe oder Shortcuts die die Arbeit vereinfachen Auf den folgenden Seiten finden Sie eine bersicht ber die Schnellzugriffe in TMV Sie sehen jeweils links den Men befehl und rechts den Bereich des Touchscreens auf den Sie dr cken um die entsprechende Funktion direkt auszuf hren Anzeige der Messwerte Tabelle oder Grafik Messung gt Grafik Dr cken Sie auf die Statuszeile re Messung gt Tabelle i i i er Hinweis Der Befehl dient zum schnellen Wech sel aus einem anderen Bereich z B Produk enge teinstellungen in den Bereich Messung nicht zum Umschalten zwischen Grafik und Tabellen
175. en Sie beim Reinigen des Touchscreen keinen starken Druck aus Reinigen Sie Geh use und Display bei Bedarf mit einem leicht mit Wasser angefeuchteten weichen Tuch Es darf auf keinen Fall Wasser in das Innere des Ger ts gelangen Reiben Sie das Ger t anschlie end trocken 9 5 Transport und Lagerung Bewahren Sie die Originalverpackung auf in der das Ger t geliefert wurde Bei einem sp teren Transport oder einer Lagerung muss das Ger t in dieser Originalverpackung transportiert bzw gelagert werden Bei Lagerung und Transport sind folgende Umgebungsbedingungen einzu halten Temperatur 10 C bis 60 C Rel Luftfeuchtigkeit max 85 nicht kondensierend 9 6 Entsorgung Wird die Verpackung nicht mehr ben tigt ist diese der rtlichen M llentsorgung zuzuf hren Die Verpackung besteht aus umweltfreundlichen Materialien die als Sekund rrohstoffe dienen k nnen Das Ger t inklusive Zubeh r und Batterien geh rt nicht in den Hausm ll Die EU Gesetzgebung fordert in ihren Mitgliedsstaaten elektrische und elektronische Ger te vom unsortierten Sied lungsabfall getrennt zu erfassen um sie anschlie end wiederzuverwerten In Deutschland und einigen anderen L ndern f hrt die Sartorius AG die R cknahme und gesetzeskonforme Entsor gung ihrer elektrischen und elektronischen Produkte selbst durch Diese Produkte d rfen nicht auch nicht von Kleingewerbetreibenden in den Hausm ll oder an Sammelstellen der rtlichen ffentl
176. en wollen drehen Sie vorher unbedingt die berwurfh lse vollst ndig vom Gewinde des Ger teanschlusses ab bersicht ber den Arbeitsablauf Nachdem die Auswerteeinheit die entsprechenden Sensoren und eventuell weitere Peripherie ger te Drucker etc angeschlossen sind schalten Sie das LMA3xxPA PMD3xxPA ein Die Software wird gestartet Anschlie end muss das System auf die Messung eines Produkts vorbereitet werden Produkt anlegen Details auf Seite 167 Kalibrieren Details auf Seite 172 Danach ist das Ger t bereit zum Durchf hren von Messungen Messen Details auf Seite 181 Hinweis Jedes Produkt das gemessen werden soll wird einmal mit den entsprechenden Produktparametern angelegt Eine Grundkalibrierung ist in der Regel nur einmal pro Produkt und Messart Feuchte Dichte notwendig hnliche Produkte m ssen separat angelegt werden k nnen jedoch eine gemeinsame Kalibrierung referenzieren LMA321PA starten Hinweis Die folgenden Beschreibungen gelten analog f r das LMA316PA Schalten Sie das LMA321PA ber den Ein Ausschalter auf der R ckseite ein Die Software des Mikrowellen Messger ts LMA321PA startet Hinweis Der Startvorgang kann bis 1 2 Minuten dauern In dieser Zeit wird der Bildschirm zwischenzeitlich schwarz Sobald das Ger t betriebsbereit ist wird die Bedienoberfl che angezeigt Falls ein Standardbenutzer angelegt ist wird die Software automatisch mit den Rechten dieses Benutzers ges
177. end auf Wenn die gew hlte Speichergr e nicht mehr zur Verf gung steht wird automatisch der gr te m gliche Wert bernommen Gegebenenfalls setzen Sie bei anderen Produkten diesen Wert herab Die Option berschreiben kann produktspezifisch aktiviert werden Sind alle verf gbaren Spei cherpl tze f r dieses Produkt belegt werden automatisch ohne R ckfrage die ltesten Eintr ge mit den neuen Messwerten berschrieben Wenn die Option nicht aktiviert ist werden weitere Messungen blockiert bis Eintr ge manuell gel scht worden sind O Hinweis Wenn Sie ein neues Produkt anlegen und das Programm nur einen geringen Wert f r die Speicherpl tze erlaubt liegt dies daran dass die bereits vorhandenen Produkte den Speicherbereich bereits beanspruchen ndern Sie dann ggf die Speichereinstellungen bei den bereits angelegten Produkten um mehr Speicherpl tze f r das neue Produkt zur Verf gung zu stellen 246 EE sartorius a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz AB Linearisierung A Offset B Offset Diese Angaben dienen zur Information bei R ckfragen und sollen nicht bearbeitet werden Dr cken Sie auf bernehmen Das Produkt ist angelegt Hinweis Die Anzahl an Produkten die angelegt werden k nnen ist abh ngig von Ihrer Ger te version Einstellungen Sie erhalten den Dialog Einstellungen Die Darstellung der Tabelle zur Anzeige der Produktein stellun
178. ent should be carried out in real time as promptly as possible This is particularly important in the following cases If the temperature of the sample is higher than the ambient temperature If hygroscopic substances are being analyzed If the substances being analyzed emit moisture Hot samples must cool down in moisture impermeable closed containers before the reference measurement is taken Number of calibration points Five calibration points with different degrees of moisture are usually required Two points are sufficient provided that the following prerequisites apply mechatronics WLM6009 a10081 6 2 6 3 30 LMA316PA LMA321PA Calibration An extremely accurate laboratory comparison procedure is used AND The calibration points are a long way apart If the laboratory comparison process provides uncertain results carry out measurements for several further calibration points This allows the statistical error to be defined more exactly and thus taken into account Non linear calibrations which may need to be separated into several segments consequently require more calibration points 0 212 A 0 208 4 0 204 g eaii 0 200 4 ct Be 0 196 sr 0 192 4 IL 0 188 Simple calibration Le S s 0 184 4 curve with two calibra jig al tion points os 05 07 09 11 13 15 0 238 er 0 230 4 Bs 0 222 T z t 0 214 A
179. ent has been dropped stored in unsuitable conditions for prolonged periods subjected to unsuitable transport conditions or contains loose parts In case of doubt the device must be sent to the manufacturer for repair or maintenance 2 3 Changes For reasons of safety you are not permitted to make changes or alterations to the instrument without our permission Opening the device adjustments servicing and repairs must only be carried out by authorized personnel DANGER Risk of death from electric shock IN Power supply device line filter and surge protection modules are safety relevant components and must not be opened or repaired EE sartorius f seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA Safety instructions O 2 4 A 2 5 2 6 Note The specified degree of protection is only guaranteed if the original connectors and sealing caps are used Installation and Maintenance DANGER Risk of death from electric shock Before installation and maintenance work or modifications the instrument must be disconnected from the power supply Connect the device to a properly installed AC outlet whose voltage corresponds to the Technical data Ensure that the plug is easily accessible so that if required it can be quickly disconnected Ensure that the electric cable cannot be damaged by sharp edges or hot objects The electric cable must not be bent or crushed Qualification of operating personne
180. equired Press the line showing the operating mode Compression test to switch to the graphical depic tion Note During the compression test the 1st display 2nd display panels show important test parameters A Moisture 10 78 26 3 C Compression test Graph Type A B SE Regression Tree Moisture 0 000 Sensor Mode P145 110 x 8 ei Tools Help History Current Type Hf 1 Measure single Werte 12 12 10 1st display panel 2nd display panel Compression test Measurement set properties tings Measurement settings You use the Measurement settings dialog to change the parameters for the measurement procedure Select Service gt MW test gt Compression test gt Measurement settings or press 2nd display Activate the continuously option if you want to take compression test readings every second process measuring devices Deactivate this option if you want to trigger and save each meas urement separately laboratory devices Activate the overwriting option to overwrite old measured values once the memory capacity reserved for the test is exceeded Memory Specify the amount of memory to be reserved for the test here Current type Determine the way the measured values are depicted in the graph here Settings and evaluation of results To evaluate test results select the graphical depiction of values Press the graph to display the Compression test properties Details on page 34 dialo
181. erJet Default Printer HP_LaserJet EAR UK O Note The Printer Configuration plug in is only available in English 2 Choose Add New Printer to add a printer EE sartorius ae seg d mechatronics WLM6009 a10081 O 3 10 54 LMA316PA LMA321PA Other functions Note When entering the printer name you must not use any blank spaces or the characters and Use the virtual keyboard to enter a printer name that can then be used to select this printer in TMV Then press Apply The dialog automatically switches to the Printer Device tab Printer Configuration Administration Printer Device Make Model Driver Printer Options Printer Version 0 1 4 test Hostname IP ei Init Port Queue 1631 mm Device URI http Device Info Set New Device URI e al Device displays all of the printers that are located in the network Select the required printer and press Next Note You can use Init to update the list for example if the required printer was not yet switched on when you called the Printer Configuration dialog Normally you must not edit the fields in the right area of the tab These are only intended for the case when a network printer is not automatically displayed and you must manually enter the host name or IP address of the printer Under Make on the Make Model Driver tab select the printer manufacturer and then select the
182. eration the general safety precautions national regulations as well as the special safety instructions in these operating instructions are adhered to DANGER Risk of death from electric shock IN In order to adhere to EMC and safety regulations the device must be operated with the PE con ductor connected The LMA3xxPA PMD3xxPA microwave measuring device is used for measuring moisture in accordance with the measuring purpose and measuring range defined and determined in the order confirmation Only the adherence to this information is valid as intended use These operating instructions describe the connection use and maintenance of the microwave measuring device LMA3xxPA PMD3xxPA Read these instructions before connecting and using the instrument These operating instructions are part ofthe product and must be kept with the device and readily available 2 2 Unsafe conditions This device has been built and tested in accordance with EN 61 010 Safety Requirements for Electrical Equipment and has left the factory in a perfectly safe condition If it is suspected that the instrument can no longer be operated safely it must be taken out of service and marked appropriately to secure it against further use The safety of the user may be compromised by the device if the measuring device sensor or accessories show visible signs of damage the instrument no longer works as intended the power cable or the plug are damaged the instrum
183. erer Zeilen Dr cken Sie auf eine Zeile Der Sensormodus ist markiert Dr cken Sie auf Kopieren Markierte Zeilen werden kopiert und als neue Werte in die Tabelle eingef gt Dr cken Sie auf Schlie en Der Kopier Modus ist beendet Neu Hinweis F r diese Einstellungen m ssen Sie mit Zugriffsrechten mindestens der Stufe 4 angemeldet sein W hlen Sie im Men Bearbeiten gt Neu Sie erhalten den Dialog Sensormodus HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz Bibliothek 2 Drucken Sie auf Bibliothek Wahlen Sie einen Sensormodus aus der Liste Die Eigenschaften des gew hlten Sensormodus werden im Dialogfeld bernommen und k nnen noch weiter ver n dert werden 3 Dr cken Sie auf ein Eingabefeld Sie erhalten den Dialog zur Zahleneingabe Details auf Seite 268 bzw zur Texteingabe Details auf Seite 267 Geben Sie die gew nschten Parameter ein und vergeben Sie einen Namen f r den neuen Sensormodus 4 Dr cken Sie auf bernehmen VG Der Sensormodus ist angelegt Einstellungen Sie erhalten den Dialog Einstellungen Die Darstellung der Tabelle zur Anzeige der Produktein stellungen kann hier individuell angepasst werden Lesen Sie hierzu Einstellungen f r Tabellen Details auf Seite 269 Drucken Die Parameter f r einen oder mehrere Sensormodi k nnen ausgedruckt werden Die Tabelle wird nun im Modus zum Drucken angezeigt das hei
184. esonance technology works completely independently of the colour of the product Core moisture determination Unlike other methods Sartorius devices determine the entire content of physically bound water surface and core moisture since the microwaves penetrate the entire sample Empty sensor adjustment You use an empty sensor adjustment to tell the system that the sensor is empty Empty might also mean that the measuring cup used to measure the product has been placed on the sensor but is empty There is a soft empty sensor adjust and a hard empty sensor adjust In the case of a hard empty sensor adjust the empty point currently defined in the system is redefined using the current sensor state In the case of a soft empty adjust the user simply informs the device that the sensor is empty Measurements are still based on the empty state defined by the last hard empty sensor adjust lons lonic particles can influence results in the case of many procedures The Sartorius method uses the polar nature of the water molecule thus making it extremely selective when detecting water Long term stability Since two independent parameters are measured against a zero point empty state that is calcu lated anew each time the calibrations do not change as a result of external effects Material moisture The absolute water content of a material as opposed to relative values for air humidity for example which are specified in a temperature
185. fur den Verdichtungstest gewonnen werden sollen Prozessmessgerate Die Messungen werden dann im Sekundentakt durchge f hrt Deaktivieren Sie die Option wenn Sie jede Messung einzeln starten und speichern wollen Labormessgerate overwriting Aktivieren Sie diese Option wenn bei berschreiten der f r den Test reservierten Speicherkapa zit t alte Messwerte berschrieben werden sollen Speicher Bestimmen Sie hier wieviel Speicherpl tze f r den Test in Anspruch genommen werden sollen Aktueller Typ Bestimmen Sie hier die Darstellung der Messpunkte in der Grafik Info Programmversion Hier wird die Versionsnummer der zur Zeit installierten Software angezeigt HE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz IS SE Durchsuchen Backup Wiederherstellen Backups k nnen je nach Ger t und Konfiguration der Anlage entweder auf einen direkt am Ger t angeschlossenen USB Stick oder auf einen externen PC gemacht werden Im Dialog Backup dr cken Sie auf das obere Listenfeld und w hlen entweder Backup Seite 265 Wiederherstellen Seite 265 oder Fabrikeinstellungen wiederherstellen Seite 266 Backup auf USB Stick nur bei Laborger ten Voraussetzungen Bevor Sie diese Funktion nutzen stecken Sie an der USB Schnittstelle des Ger tes einen USB Stick ein Auf dem USB Stick muss gen gend Speicherkapazit t vorhanden sein Dr cken Sie
186. g EE sartorius SR mechatronics WLM6009 a10081 LMA316PA LMA321PA Calibration 34 x i Compression test properties The Ranges tab allows you to set the parameters for the measurement ranges in which readings are taken displayed in green in the graph and for the measurement range indicating the empty sensor state displayed in red in the graph On the Scale Graph Type Regression tab you define parameters for modifying the depiction of the graphic Select free for Regression and press Apply The measuring points are connected by a line 238 lt Tools Help Back Current Type W 1 Measure single Vales 12 12 10 Graph Type A B Regression free oi Sensor Mode P145 110 Off moisture B value mmw 0 30228 0 1000 1 9000 2 9000 3 9000 4 9000 A Value o A lt Y ES adjust Page back Step bach I lt Gato first Start Goto Step Forward Page forward Goto last gt gt i The readings found should all be positioned on a a straight line going through the neutral point if possible Please contact the Sartorius customer service if this cannot be achieved Once you are satisfied with the results press the Submit to sensor mode control A Set to Sensor Mode The sensor mode you selected is adapted to the test results Print values Selected measurement values can be printed out See page 53 for information on how to con
187. g the menu Calibration type You can modify the calibration curve If there is no directly proportional relationship between the reference moisture and the measured moisture select a non linear calibration type here Since products can display different behaviour in different measurement ranges you can split the calibration curve into various segments In the simple calibration mode the splitting of segments is determined automatically Here you determine whether the calibration curve has an extremum and specify the way in which temperature and density moisture are to be taken into account Complex curves require a high number of measured values If measured values reference values or correction values do not fall into the range defined in the global settings gt page 93 the system issues an error message Change the settings for the measurement ranges or take further calibration measurements Expert mode You can open the expert mode from the Calibration type dialog You can manually adjust previously defined settings here You can move the automatically calcu lated limits of the individual curve segments If you select Manual correction for the correction of the temperature or density moisture a slide control is displayed in the graphical depiction of the calibration curve You can use it to manually correct the calibration curve Manual correction using slide control or by entering Temp Zoom numbers in the gra
188. ge 95 All values Details on page 95 The table is now displayed in edit mode i e the controls for selecting one or more rows page 70 are displayed at the bottom 1 Press a row to select it 2 Press the control to start editing EI If you selected the option for entering a single value remark reference density etc the corre sponding Numerical input Details on page 125 or Text input Details on page 124 dialog is displayed If you selected the option for entering the type the Type gt page 86 dialog is displayed If you selected the option for entering all values the Calibration properties page 88 dialog is displayed O Note You can also press the relevant field in a table entry to enter a reference value type or remark If you do so the input dialog is displayed 94 EE sartorius e H mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 2 Note Values are displayed rounded off in accordance with the settings in Global settings Details on page 108 When making entries enter all decimal places Press Close The input process is complete Remark The Text input Details on page 124 dialog appears Remarks are free text entries Press Apply to add the entry to the table Note This dialog is displayed automatically following every measurement of a calibration value Typically you enter the number of the sample here This allows samples and measured v
189. gen f r die Kalibration zu ndern Le sen Sie dazu den Abschnitt Typeneinst Details auf Seite 232 Betriebsart Hier wird der aktuelle Vorgang angezeigt Messung Details auf Seite 213 Kalibration Details auf Seite 225 Angezeigt wird zus tzlich ob f r Feuchte oder f r Dichte kalibriert wird Dr cken Sie auf das Anzeigefeld um zwischen Tabelle und grafischer Darstellung zu wechseln Produkteinstellungen Details auf Seite 244 Verdichtungs Test Details auf Seite 262 Sensormodi Details auf Seite 251 MW Ger te Details auf Seite 254 Produkt Angezeigt wird das Produkt das gemessen wird oder f r das kalibriert wird Rechts daneben wird der f r die Kalibration gew hlte Offset f r Feuchte angezeigt 1 Dr cken Sie auf die Anzeigefl che um ein anderes Produkt auszuw hlen Sie sehen den Dialog Produktauswahl Details auf Seite 214 Die Produktauswahl ist auch ber die Men punkte Messung Details auf Seite 213 bzw Kalibration Details auf Seite 225 erreichbar 2 Dr cken Sie auf die Anzeige f r Feuchte Offset um f r den Feuchte Offset einen anderen Wert einzugeben SHE sartorius 209 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz 13 3 210 Schaltflachen Messung Kalibration Diese Schaltflachen nutzen Sie wahrend der Messung und der Kalibration Es werden nur die Schaltfl chen angezeigt die im jeweiligen Zusammenhang gedr ckt werden k
190. gen kann hier individuell angepasst werden Lesen Sie hierzu Einstellungen f r Tabellen Details auf Seite 269 Drucken Die Parameter f r markierte Produkte k nnen ausgedruckt werden Hinweise zum Anschluss eines Druckers finden Sie auf Seite 198 W hlen Sie im Men Produkteinstellungen gt Drucken Die Tabelle wird nun im Modus zum Drucken angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen Seite 210 zum Markieren einer oder mehrerer Zeilen Dr cken Sie auf eine Zeile um diese zu markieren Hinweis Sie k nnen mehrere Produkte markieren Dr cken Sie auf die Schaltfl che Drucken Die Parameter der markierten Produkte werden in Tabellenform ausgedruckt Dr cken Sie auf Schlie en Das Drucken der Werte ist beendet Die Tabelle wird im Format csv exportiert und auf dem angeschlossenen USB Stick gespeichert Dr cken Sie auf Bearbeiten um den Dateinamen zu ndern Hinweis Wenn Sie das Programm am PC nutzen erhalten Sie den Dialog Export Hier w hlen Sie einen Speicherort auf dem PC und hier ndern Sie gegebenenfalls den Namen der Exportdatei Hinweis Microsoft Excel 2003 Das weit verbreitete universelle Exportformat csv ist f r Excel 2003 nicht richtig zu interpretieren Benennen Sie die csv Datei in txt um und importieren Sie sie in Excel 2003 mit der Importfunktion HE sartorius 247 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz 13 7 Syste
191. hatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz 13 2 206 O Hinweis Abh ngig von Ihrer Anmeldung und den damit verbundenen Rechten sind eventuell nicht alle beschriebenen Men punkte zug nglich Messung Produkt Bearbeit 1 i 12 J Bemerkung Lou T Kalibration Tabelle Einstelluy G L schen 2 12 122 1212 g Produktelnst gi Grafik Drucken i 3 123 Kopieren 121s g Systemeinste Werte Export a 4 124 f Serice 1 Anzei 7 statistik s 5 125 Benutzerwec 2 Anza e 5 sprachen Ausgew hlte Men punkte sind wei unterlegt Entsprechend dem ausgew hlten Men punkt werden die dazugeh rigen Untermen s angezeigt Entsprechend der Ihnen zugeteilten Benutzerrechte werden einige Men punkte nicht angezeigt In einigen Dialogen k nnen bestimmte Einstellungen nur mit entsprechenden Rechten vorge nommen werden Die eingestellten Werte werden dann grau hinterlegt angegezeigt Die Ziffernfolge unterhalb der Men punkte und des Symbols verdeutlicht die Auswahl unab h ngig von der eingestellten Sprache Dr cken Sie auf einen der Eintr ge im Men um einen Befehl aufzurufen Gegebenfalls erscheint ein weiterer Dialog in dem Einstellungen vorgenommen werden Befehle wie zum Beispiel Drucken oder L schen sowie Befehle die die Darstellung der Anzeige ver ndern werden direkt ausgef hr
192. he controls page 70 for selecting one or more rows are displayed at the bottom Press the row containing the incorrect value The value is selected EE sartorius e H mechatronics WLM6009 a10081 LMA316PA LMA321PA Calibration O Note The deviation of the reference values from the calibration values is displayed in the Moisture dev or Density dev table Sort the table by these values This allows you to quickly find the value with the largest deviation Sort the table again to place the value with the greatest negative deviation at the top 2 Press Delete EI The selected value is deleted x 3 Press Close The deletion process is complete Individual calibration points can be represented with various symbols This allows you to highlight the values for samples taken on different days for example gt page 86 To a great extent the calibration curve is automatically determined by the device However you can enter parameters to refine the calibration curve For more information see Type settings Details on page 91 Offset The offset of a calibration curve can be corrected Doing so results in the parallel displacement of the entire curve An offset is used in the following cases You need to correct constant calibration deviations The calibration of another product is referenced for the measurement The determined moisture value is required or displayed at a point during the production proce
193. he import function Graph The graph of the calibration is for display purposes only Values cannot be changed If the Correction option is activated you can modify the correction value for the temperature and or density using the slide control or by entering numbers I A Temp em Zoom MW moisture 038 1008 0 372 Se 0 368 4 Sa 0 364 4 ae as 1 a 0 360 0 356 0 352 4 0 348 4 T T T T T G 12 50 12 60 12 70 12 80 12 90 13 00 13 10 13 20 13 30 Reference moisture The graph shows the deviation of the calibration values from the calculated calibration curve f Individual calibration points are depicted using different symbols in accordance with the settings IE i Mm Type gt page 86 Calibration points which are not used to calculate the curve are displayed in green O Note Calibration measurements can be made whilst the graph is displayed The input dialogs for remarks and reference values are displayed automatically 2 Press on the Calibration Moisture operation mode or the graphic icon to dis play the table instead of the graph Zoom 1 Enter a value into the Zoom box or click the arrow buttons to zoom in or out ofthe graph N Click the Zoom in or Zoom out control to change the zoom factor by 5 with each click Gei Q Once you have zoomed in on the graph you can move the graphical display by pressing the graph and dragging it Otherwise on your PC c
194. he number of products which can be created depends on the device version SHE sartorius 105 cece 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Settings The Settings dialog appears You can customize the depiction of the table for displaying the product settings here See Settings for tables Details on page 126 Print You can print the parameters of the selected products See page 53 for information on how to connect a printer Select Print from the Product settings menu The table is now displayed in print mode i e controls page 70 for selecting one or more rows are displayed at the bottom Press a row to select it Note You can select multiple products Press the Print button The parameters of the selected products are printed out as a table Press Close The printing of the values is complete The table is exported to a csv file and stored on the connected USB stick Press Edit to change the file name Note If you are using the program on your PC the Export dialog appears Specify a storage location on the PC and change the name of the export file if necessary Note Microsoft Excel 2003 The widespread and universal csv export format cannot be 106 properly interpreted for Excel 2003 Rename the csv file as txt and import it into Excel 2003 using the import function HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Oper
195. he settings of one or more sensor modes The table is now displayed in print mode i e controls page 70 for selecting one or more rows are displayed at the bottom Press a row to select it Press the Print button How you now continue depends on whether the printer is connected directly to the measuring device or if you are working on an external PC Press Close The printing of the values is complete Export The table is exported to a csv file and stored on the connected USB stick Press Edit to change the file name Note If you are using the program on your PC the Export dialog appears Specify a storage location on the PC and change the name of the export file if necessary Note Microsoft Excel 2003 The widespread and universal csv export format cannot be properly interpreted for Excel 2003 Rename the csv file as txt and import it into Excel 2003 using the import function Read Note You need to be logged on with at least level 4 access rights to use this function This function enables the sensor modes of most sensors to be read as long as the sensor in ques tion is connected to the device using a data wire You use this function if modes are not imported automatically when your devices are started up or if you want to read in sensor modes again later on Communication MW devices If you want to control the device via a PC using the TMV make an entry for the device here page 113 and co
196. he temperature correction function applied for calibration Source Here you select whether to measure the temperature of the product and if so which temperature sensor to use The selection options in the list depend on the individual system configuration Temperature measurement can also be deactivated Source Off or given a predefined value Source Fixed Port If one of the analog outputs of a TC MPC card is used for temperature measurement you define which of the four outputs is to be used here Fixed If Fixed is selected for Source you can enter the temperature value to be used in all cases for measurements here Stability Specify a time span in seconds and a variation range in C here Ifthe measured temperature does not fluctuate by more than the selected value within the specified period of time it is considered to be stable Analog If you are using analog temperature measurement or are measuring the temperature via the IO MPC you define the temperature values that correspond to the input values 0 mA or 4 mA and 20 mA here Sensor temperature These settings are required for the temperature correction function for the empty sensor state The options correspond to the options for the product temperature Analog outputs In addition to the digital outputs the process measuring devices have a different number of analog outputs The number of analog outputs depends on the configuration level of the device in questi
197. hen alle zwischenzeitlich auf dem Ger t gespeicherten A Daten verloren Erstellen Sie vor dem Einlesen eines Backups ein aktuelles Backup Dr cken Sie im Dialog Backup nach Auswahl von Wiederherstellen auf das untere Listenfeld W hlen Sie eine der angezeigten Backup Dateien und dr cken Sie auf bernehmen SHE sartorius 265 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz emm 2 B Durchsuchen 3 1 2 2 13 9 1 2 N 3 13 10 1 13 11 e e e e 266 Wird das gew nschte Backup nicht in der Liste angezeigt dr cken Sie auf Durchsuchen und w hlen Sie den Speicherort des gew nschten Backups Die Backup Datei muss mit einem Ger t des gleichen Typs erstellt worden sein W hlen Sie die Backup Datei und dr cken Sie ffnen Es wird der Zustand des Ger tes wiederhergestellt der durch das Backup gesichert wurde Fabrikeinstellungen wiederherstellen Achtung Beim Wiederherstellen wird das Ger t auf einen vordefinierten Zustand zur ckgesetzt A Messungen Kalibrationen sowie Einstellungen f r Sensormodi oder Produkte gehen dabei verloren Erstellen Sie vorher ggf ein Backup der aktuellen Einstellungen Falls das Ger t ber ein Netzwerk mit einem externen PC verbunden ist m ssen Sie u U die IP Adresse ndern da mit den Fabrikeinstellungen dem Ger t auch wieder die werkseitig voreingestellte IP Adresse zugewiesen wird Dr cken Sie im Dialog Backup auf das obe
198. hernet TCP IP Density value on PMD320PA Hiermit kann beim PMD320PA festgelegt werden ob auch die Dichte auf dem Display angezeigt werden soll Max age of ES adjust day Nach jedem Speicherzyklus wird das Alter der letzten Leer messung berpr ft und bei berschreiten des angegebe nen Wertes in Tagen ggf eine Warnung ausgegeben z B Aufleuchten der Warnleuchte Max freq dev of ES adjust MHz Definiert die gew nschte Genauigkeit Stabilit t der Leer messung Wird diese Stabilit t nicht erreicht wird die Mes sung mit der Meldung Leerpr fungsfehler abgebrochen Allgemein ist ein Wert von 0 01 MHz optimal Dies betrifft alle Leermessungen d h auch die automatisch durchge f hrten in einem Labor oder Prozessmessablauf Meas trigger input no On line device Optional k nnen mit einem 24 V digitalen Eingang die Mit telwerte aus den Messwerten ausgeblendet werden Hier wird definiert um welche Art von Prozessmessger t es sich handelt Time for float mean sec Measurement interval sec Aus allen laufenden Messungen werden ber die hier defi nierte Zeit gleitende Mittelwerte f r Feuchte Dichte Tem peratur usw berechnet und periodisch abgespeichert Das Intervall f r das Speichern wird unter Measurement inter val festgelegt Time for probe sec Maximum emptying time sec Zeitraum f r den nach Dr cken der Taste Probenent nahme alle Messwerte gemittelt un
199. hierzu Analoganzeige Dr cken Sie auf bernehmen Die Werte werden entsprechend den gew hlten Einstellungen angezeigt Optionen Wenn Sie ein Produkt ausw hlen f r welches bereits eine gro e Anzahl an Messwerten im Ger t gespeichert ist kann das Holen der Werte einige Minuten dauern W hlen Sie hier die Anzahl der Werte aus die bei der Initialisierung vom Ger t geholt werden soll auto Alle im Ger t gespeicherten Werte werden geholt Die Anzahl der Werte die f r ein Produkt gespeichert werden kann wird in den Produkteigenschaften Seite 244 festgelegt Wenn eine Prozessmessung gestartet wird werden die restlichen Werte im Hintergrund geholt so dass Oberfl che und Messger t wieder auf den gleichen Stand gebracht werden HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz 13 5 Kalibration F r jedes Produkt muss einmal eine Kalibration durchgef hrt werden Jede Kalibration beginnt mit der Produktauswahl Details auf Seite 225 W hlen Sie ob Sie eine Feuchte Kalibration Details auf Seite 226 oder eine Dichte Kalibra tion Details auf Seite 235 durchf hren werden Beachten Sie bitte dass der Vorgang der Kalibration im Labor und im Prozess unterschiedlich ist Jedem Produkt ist genau eine Kalibration zugeordnet Diese kann im Laufe der Zeit erg nzt und verfeinert werden Die Kalibrationstabelle mit allen eingegebenen Werten wird automatisch gespe
200. hlen Sie im oberen Feld die Funktion Wiederherstellen Im unteren Feld werden nun in einer Liste alle zur Verf gung stehenden Backups angezeigt W hlen Sie das gew nschte Backup aus der Liste aus und dr cken Sie bernehmen Die Daten werden geladen und der im ausgew hlten Backup gespeicherte Zustand wieder hergestellt Wenn Sie ein Backup von einem externen PC herstellen m chten und dieses nicht in der Liste angezeigt wird dr cken Sie auf Durchsuchen Sie erhalten einen Windows blichen Dialog in dem Sie das Verzeichnis des Backups das wiederhergestellt werden soll ausw hlen k nnen Markieren Sie dann die gew nschte Backup Datei und dr cken Sie ffnen Fabrikeinstellungen wiederherstellen Mit dieser Funktion kann das System komplett auf den Zustand des vorgefertigten internen Backups zur ckgesetzt werden Achtung Beim Wiederherstellen gehen alle Messungen Kalibrationen sowie Einstellungen f r Produkte und Sensormodi die Sie vorgenommen haben verloren Erstellen Sie ggf zur Sicher heit ein Backup des aktuellen Zustands bevor Sie diese Funktion ausf hren Falls das Ger t ber einen externen PC gesteuert wird m ssen Sie u U die IP Adresse wieder neu zuweisen da auch diese auf die Fabrikeinstellung 172 28 1 1 zur ckgesetzt wird Voraussetzungen Das Messger t ist eingeschaltet und Sie sind mit Zugriffsrechten der Stufe 4 oder h her angemeldet siehe Backup erstellen Stoppen Sie ggf laufende Messungen W
201. hneter Text enth lt Hinweise und weitergehende Informationen Begriffe die Sie auf der Bedienoberfl che wiederfinden sind im Fettsatz dargestellt ebenso Verweise auf andere Stellen in dieser Dokumentation sowie Verweise auf weitere Dokumenta tionen Men punkte sind durch eine spitze Klammer getrennt Men gt Untermen gt Neu Markenrechtliche Hinweise Excel Microsoft Windows und Windows Vista sind eingetragene Marken bzw Marken der Micro soft Corporation in den USA und oder anderen L ndern HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA 2 Sicherheitshinweise 2 1 AN 2 2 2 3 AN Bestimmungsgem er Gebrauch Die gelieferte Anlage darf nur zu dem im Angebot oder dem in der Auftragsbest tigung beschrie benen Zweck unter Ber cksichtigung der technischen Daten eingesetzt werden Zweckentfrem deter Einsatz ist nicht zul ssig Die einwandfreie Funktion und Betriebssicherheit des Ger tes kann nur dann gew hrleistet werden wenn bei der Benutzung die allgemein blichen Sicher heitsvorkehrungen nationalen Vorschriften sowie die speziellen Sicherheitshinweise in dieser Anleitung beachtet werden GEFAHR Lebensgefahr durch elektrischen Stromschlag Zur Einhaltung der EMV und Sicherheitsvorschriften muss das Ger t mit angeschlossenem PE Leiter betrieben werden Das Mikrowellen Messger t LMA3xxPA PMD3xxPA dient zum Messen von Feuchtigkeit gem dem in der Auftragsbest t
202. i administrativen Aufgaben oder verschmutztem Touchscreen kann es hilfreich sein zus tzlich eine Tastatur und Maus an den entsprechend farblich gekennzeichneten Buch sen an der Ger ter ckseite anzuschlie en Externer PC Bei Steuerung des Ger ts ber einen externen PC erfolgt die Bedienung ber Tas tatur und Maus des PCs Lesen Sie dazu das Kapitel Steuerung ber externen PC Details auf Seite 159 Virtuelle Tastatur deaktivieren Wenn Sie das Ger t nicht ber den Touchscreen bedienen sondern ber Tastatur k nnen Sie zur einfacheren Bedienung die Virtuelle Tastatur deaktivieren Dadurch wird zur Eingabe von Werten oder Texten z B Bemerkungen ein einfaches Eingabefeld eingeblendet in das Sie die Zahlen oder Texte direkt ber die Tastatur eingeben mechatronics WLM6009 a10081 LMA316PA LMA321PA Inbetriebnahme 1 W hlen Sie das Men Systemeinstellungen gt Globale Einstell und die Registerkarte Einstel lungen 2 2 Deaktivieren Sie die Option Virtuelle Tastatur 3 Starten Sie das Programm neu damit die nderung wirksam wird O Hinweis Die Beschreibungen in diesem Handbuch beziehen sich auf die Bedienung per Touch screen Der Unterschied besteht dabei lediglich in der Formulierung W hrend Sie am Touch screen eine Taste oder einen Men eintrag dr cken w rden Sie bei Bedienung ber Maus und Tastatur eine Taste anklicken 158 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA
203. ibrieren 168 Wenn Sie mehrere Produkte messen teilen Sie die ca 2000 Speicherplatze durch Eingabe entsprechender Werte zwischen den Produkten auf e Die Option berschreiben kann produktspezifisch aktiviert werden Sind alle verf gbaren Speicherpl tze f r dieses Produkt belegt werden automatisch ohne R ckfrage die ltesten Eintr ge mit den neuen Messwerten berschrieben Hinweis Wenn Sie ein neues Produkt anlegen und das Programm nur einen geringen Wert f r die Speicherpl tze erlaubt liegt dies daran dass die bereits vorhandenen Produkte den Speicherbereich bereits beanspruchen ndern Sie dann ggf die Speichereinstellungen bei den bereits angelegten Produkten um mehr Speicherpl tze f r das neue Produkt zur Verf gung zu stellen Messung gt Mittel Hier legen Sie fest wieviele Messungen bei diesem Produkt zum Ermitteln des Mittelwerts jedesmal durchgef hrt werden m ssen Hinweis Die Eintr ge f r MW Typ und im Bereich AB dienen nur der Information bei R ckfragen und k nnen nicht bearbeitet werden Dr cken Sie auf bernehmen Das Produkt ist angelegt F r das Produkt k nnen jetzt die Feuchte Kalibration und die Dichte Kalibration durchgef hrt werden Hinweis Sie k nnen die Parameter f r ein Produkt ndern kopieren oder ausdrucken Ein Produkt kann wieder gel scht werden Hinweise zu diesen Punkten finden Sie im Referenzkapitel ab Seite 244 HE sartorius seg x mechatronics WLM6009 a1
204. ically starts up with the rights of that user You do not need to log in separately If none of the registered users is defined as the default user the system asks you to enter a user name and password Note To enable you to log in when you start the device for the first time we will send you a user name and password separately We recommend that you then change this password to prevent unauthorized access see page 49 Recommendation After switching on the device wait a few minutes before taking the first meas urements since this allows the device to reach its optimum operating temperature Turning the LMA321PA off When you have finished your work simply turn off the LMA321PA using the on off switch on the rear of the device You do not need to close the operating software first To restart the operating software without turning off the device press Service gt Reset Note that you need at least Level 4 access rights to do this EE sartorius a eegg mechatronics WLM6009 a10081 LMA316PA LMA321PA Startup Exception If the LMA321PA is controlled via an external PC the operating software running there must be terminated by clicking on the Close symbol in the title bar If you are logged on with access rights of level 4 or higher you can also close the software by choosing Service gt Close 5 6 Information about using the software You control the TMV software in one of the following ways By pressing the cont
205. ich das Messen die h chste Stufe 5 bietet Zugriff auf alle Einstellungen Men punkte f r die ein Benutzer keine Rechte hat bleiben f r diesen Benutzer unsichtbar Einzelne Werte in Dialogen sind f r manche Benutzer ggf nicht editierbar hier werden jedoch die eingestellten Werte zur Information ange zeigt bersicht ber die Benutzer und ihre Zugriffsrechte 0 Messungen k nnen durchgef hrt werden Es k nnen keine Messwerte gel scht werden Es k nnen Messwerte gel scht werden Messungen f r Kalibrationen k nnen durchgef hrt werden Kalibrationen k nnen bearbeitet werden kh ON Die Systemeinstellungen mit Ausnahme der Benutzerverwaltung k nnen bearbeitet werden wie z B Sensormodi oder Druckerkonfiguration Backups k nnen erstellt bzw wieder eingespielt werden 5 Service Stufe maximale Zugriffsrechte Hier k nnen neue Benutzer angelegt bzw Zugriffsrechte vorhandener Benutzer bearbeitet werden Verdichtungstest oder Erweiterungen falls installiert sind verf gbar Es muss mindestens ein Benutzer der Stufe 5 Service angelegt sein Ein solcher Benutzer ist bereits bei Auslieferung vordefiniert Den zugeh rigen Benutzernamen und das Passwort bekommen Sie separat mitgeteilt Neuen Benutzer anlegen Voraussetzung Sie sind mit Zugriffsrechten der Stufe 5 Service angemeldet 1 W hlen Sie den Men befehl Systemeinstellungen gt Konfiguration gt Benutzerkonfig Seite 258 2 Im Dialog Benu
206. ich of the details need to be changed and in what way depends on the how the requirements have changed Example When measuring a product of higher moisture or density extend the search range by a lower Start frequency value Press on Library to be shown a list of the common sensors in a new dialog Pick the name of the connected sensor from the list In some cases diverse modes are shown for one sensor lo med hi EE sartorius e mechatronics WLM6009 a10081 LMA316PA LMA321PA Other functions Sensor mode library O New names Version 1 0 E35 10 S E83 10 H242 96 lo H242 96 med H242 96 hi H177 40B lo H177 40B hi H177 46 lo H177 46 hi 8 Having adopted the selected mode the parameters of this mode are shown in the Sensor modes dialog You can accept or adjust them O Note Whereas the software does not limit the number of sensor modes you can define you should remember that sensor modes consume memory capacity That is to say the more modes you create the less space you have left for storing analysis results 52 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Other functions 9 3 Setting up printers Before you can directly print from the measuring instrument you must connect a printer to the unit If the measuring instrument is connected using an IP network in principle you can use any printer that can be accessed in this network However you can also connect a printer directly to
207. ichen Entsorgungsbetriebe abgegeben werden Hinsichtlich der Entsorgung wenden Sie sich daher in Deutschland wie auch in den Mitgliedsstaaten des Europ ischen Wirtschafts raumes bitte an unsere Service Mitarbeiter vor Ort oder an unsere Service Zentrale in G ttingen Sartorius AG Weender Landstrasse 94 108 37075 G ttingen In L ndern die keine Mitglieder des Europ ischen Wirtschaftsraumes sind oder in denen es Wu Keine Sartorius Filialen gibt sprechen Sie bitte die rtlichen Beh rden oder Ihr Entsorgungsun ternehmen an Vor der Entsorgung bzw Verschrottung des Ger tes sollten die Batterien entfernt werden und einer Sammelstelle bergeben werden Mit gef hrlichen Stoffen kontaminierte Ger te ABC Kontamination werden weder zur Reparatur noch zur Entsorgung zur ckge nommen Ausf hrliche Informationen mit Service Adressen zur Reparaturannahme oder Entsor gung Ihres Ger tes finden Sie auf unserer Internetseite www sartorius com oder k nnen ber den Sartorius Service angefordert werden SHE sartorius 191 seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA Technische Daten 10 Technische Daten Stromversorgung 110 230 V AC 50 60 Hz Leistungsaufnahme 60 VA Sicherungen 2 Sicherungen 2 AT 250 V AC 5 x 20 mm Umgebungstemperatur 0 45 C Datenschnittstellen 2x RS 232 COM Service 1x Ethernet 3x USB 1x Analogeingang 0 4 20mA f r optionalen IR Sensor ber Sensor Anschluss 1x An
208. ichert Produktauswahl Den Dialog zur Produktauswahl erhalten Sie ber das Men oder indem Sie auf den Produkt namen dr cken Produktauswahl EE Anz Kal Verweis Coffee TEWS Elektr IO 5 selbst 2 Coffee TEWS Elektr o 3 Cigarett 50 o 41 REFER Verweis auf Kalibration la lt i gt bernehmen Abbruch Zum Anfang Seite zur ck Zur ck Sprung Seite vor Zum Ende Produkte werden ber den Men punkt Produkteinstellungen Details auf Seite 244 neu ange legt O Hinweis Das aktuell gew hlte Produkt ist in der Spalte Nr mit einem gr nen H kchen markiert O Hinweis Das Produkt REFERENCE wird nur f r die optionale Funktion Referenzstandard ben tigt 1 Dr cken Sie auf einen Spaltenkopf um die Tabelle zu sortieren Die aktuelle Sortierung wird durch einen Pfeil in einem Spaltenkopf angezeigt 2 Dr cken Sie auf die Zeile mit dem Namen des Produktes f r das kalibriert werden soll O Hinweis Produkte mit hnlichen Eigenschaften k nnen dieselbe Kalibration referenzieren Falls ein Produkt die Kalibration eines hnlichen Produktes referenziert finden Sie dazu Informationen in der Zeile Verweis auf Kalibration Bei Produkten mit eigener Kalibration wird in der Spalte Kal Verweis der Hinweis selbst angezeigt SHE sartorius 225 seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz O Hinweis Falls nicht alle P
209. ie Eigenschaften des gew hlten Sensormodus werden im Dialogfeld bernommen und k nnen noch weiter ver n dert werden Dr cken Sie auf bernehmen um die ge nderten Werte zu bernehmen Dr cken Sie auf Schlie en Das Bearbeiten der Werte ist beendet L schen Hinweis F r diese Einstellungen m ssen Sie mit Zugriffsrechten mindestens der Stufe 4 angemeldet sein Ein selbst angelegter Sensormodus kann aus der Liste gel scht werden Automatisch eingele sene Sensormodi k nnen nicht gel scht werden W hlen Sie im Men Bearbeiten gt L schen Die Tabelle wird nun im Modus zum L schen angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen gt Seite 210 zum Markieren einer oder mehrerer Zeilen Dr cken Sie auf eine Zeile Der Sensormodus ist markiert Dr cken Sie auf L schen Der Sensormodus wird ohne weitere Abfrage gel scht Dr cken Sie auf Schlie en Der L sch Modus ist beendet Kopieren Hinweis F r diese Einstellungen m ssen Sie mit Zugriffsrechten mindestens der Stufe 4 angemeldet sein Ein Sensormodus kann kopiert werden Kopierte Eintr ge werden in der Tabelle mit demselben Namen eingef gt Durch Kopieren eines Sensormodus lassen sich auf einfache Weise hnliche Eintr ge anlegen W hlen Sie im Men Bearbeiten gt Kopieren Die Tabelle wird nun im Modus zum Kopieren angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen Seite 210 zum Markieren einer oder mehr
210. ie auf die Schaltfl che Bibliothek um eine Liste der g ngigen Sensoren in einem neuen Dialog angezeigt zu bekommen W hlen Sie aus der Liste den Namen des angeschlossenen Sensors In einigen F llen werden f r einen Sensor verschiedene Modi angezeigt lo med hi Sensormodi Bibliothek Neue Namen Version 1 0 E35 10 S E83 10 H242 96 lo __ H242 96 med H242 96 hi H177 40B lo H177 40B hi H177 46 lo H177 46 hi Nachdem Sie den gew hlten Modus bernommen haben werden im Dialog Sensormodus die Parameter des gew hlten Modus angezeigt Sie k nnen diese bernehmen oder anpassen HE sartorius 197 mechatronics WLM6009 a10081 LMA316PA LMA321PA Weitere Funktionen 12 3 1 198 Hinweis Die Anzahl der Sensormodi die Sie anlegen k nnen wird von der Software im Prinzip nicht beschr nkt Beachten Sie jedoch dass die Sensormodi Speicherplatz ben tigen d h um so mehr Sensormodi Sie anlegen desto weniger Speicherplatz steht f r Messungen zur Verf gung Drucker einrichten Bevor Sie direkt vom Messger t aus drucken k nnen muss ein Drucker angeschlossen und eingerichtet werden Ist das Messger t mit einem IP Netzwerk verbunden kann im Prinzip jeder in diesem Netzwerk erreichbare Drucker verwendet werden Sie k nnen jedoch auch einen Drucker direkt am USB Anschluss des Messger ts anschlie en Hinweis F r die Druckerkonfiguration m ssen Sie mit Zugriffsrechten mindestens der Stufe 4 angemel
211. ie unter Grafik gt Einstel lungen die Option auto Temp Temperaturkorrektur Wenn f r die Kalibration eine Temperaturkorrektur gew hlt ist gt Seite 241 erscheint Uber der Grafik ein Schieberegler und ein Eingabefeld Temp 1 Ver ndern Sie hier manuell die Temperaturkorrekturwerte indem Sie den Schieberegler verstellen einen Wert manuell eingeben oder auf die Felder mit den Pfeilen klicken Die Kurven die den Korrekturbereich markieren werden in der Grafik verschoben Grafik gt Einstellungen Die grafische Darstellung kann vergr ert bzw verkleinert angezeigt werden Den Dialog f r die im folgenden beschriebenen Einstellungen rufen Sie auf indem Sie auf eine der beiden Achsen in der grafischen Darstellung klicken SHE sartorius 239 seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz auto 1 Aktivieren Sie die automatische Anpassung der Darstellung indem Sie auf das K stchen klicken x aktiviert Werte f r x Achse und y Achse werden automatisch angepasst Zoom wird auf 100 gesetzt deaktiviert Geben Sie Werte f r die Darstellung ein Zoom 2 Geben Sie einen Wert zwischen 1 und 400 ein X Achse Y Achse 3 Geben Sie jeweils den unteren Min und den oberen Wert Max f r den Anzeigebereich ein Temperaturkorrektur Hilfslinien Feuchtekorrektur Hilfslinien Aktivieren O Hinweis Sie k nnen entweder die Temperaturkorrektur oder de Feuch
212. iensoftware neu starten um unbefugte nderungen an den Systemeinstellungen oder Kalibrationen zu verhindern Die folgenden Arbeitsschritte unterscheiden sich abh ngig davon ob Sie direkt am LMA316PA LMA321PA mit einem USB Stick arbeiten oder das Ger t ber einen externen PC steuern Backup auf USB Stick Stecken Sie den mitgelieferten USB Stick in den USB Anschluss auf der Vorderseite Hinweis Es kann einige Sekunden dauern bis der USB Stick erkannt wird und zur Verf gung steht W hlen Sie Service gt Backup Es ffnet sich der Dialog Backup Im oberen Feld ist standard m ig die Funktion Backup ausgew hlt Dr cken Sie bernehmen Das Backup wird jetzt auf den USB Stick gespeichert der Backup Dialog automatisch geschlossen Die Backup Datei wird automatisch mit dem Tagesdatum und der Uhrzeit benannt Dadurch wird vermieden dass bei einem erneuten Ausf hren der Backup Funktion versehentlich ein lteres Backup berschrieben wird Backup auf externen PC W hlen Sie Service gt Backup Es ffnet sich der Dialog Backup Im oberen Feld ist standard m ig die Funktion Backup ausgew hlt Dr cken Sie Durchsuchen Sie erhalten einen Windows blichen Dialog in dem Sie den Spei cherort f r die Backup Datei festlegen k nnen Die Backup Datei wird automatisch mit dem Tagesdatum und der Uhrzeit benannt Dadurch wird vermieden dass bei einem erneuten Ausf hren der Backup Funktion versehentlich ein lteres Back
213. iew LMA321PA Display Life touch screen i USB port y Handle Power on ready indicator LMA316PA external monitor and mouse are not part of the scope of delivery 00000000 Cem USB port Power on ready indicator SS Keyboard 2 Handle 12 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Product description 3 2 View of the device LMA316PA LMA321PA connections at the rear Temperature sensor ext On Off switch a n SWIC MW Gen 2 MW Det 1 Sensor2 Fuses MW Det 2 MW Gen 1 Sensor1 m Ethernet ll O O Connection 110 230 V AC O O I Service interface Device feet USB 2 connections Keyboard Monitor Mouse COM 1 O Note The connections marked with are optional and not available on all devices 13 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Product description gt 14 Brief description of the connections MW Gen MW Det Connection of the microwave cable to the corresponding sensor connections The measuring data is transmitted over these links Gen Generator sends the microwaves to the sensor Det Detector receives the microwave signals Attention The connections of both de
214. if there are temperature variations of more than 5 C The measurement is carried out by the device In the case of simultaneous temperature measurement the measurement is taken once a con stant temperature value is recorded Save the result by pressing the Save control Depending on the sensor used and the system settings you are asked to rotate the sample or to place a new sample into the sensor Carry out steps 6 to 10 until you are asked by the device to enter a remark EE sartorius a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Taking measurements 12 The dialog for entering a remark is shown You can enter the number of the sample here for example Then press Apply oi 13 The measured value is displayed If the measured value is outside the set alarm limits the bar is displayed in red on the screen O Note Even if several measurements are taken for a sample only one line with the average value of the measurements is shown 8 2 Printing measured values If a printer is connected via a USB port or network connection you can print the graphical depic tion of the measured values or the table if required Printing a graph 1 Press Measurement gt Graphics gt Print The standard print dialog appears you can specify the print settings and trigger printing by clicking Print Printing a table 1 Press Measurement gt Table gt Print 2 Inthe table select the values you want to print or pres
215. igung definierten und festgelegten Messzweck und Messbe reich Nur die Einhaltung dieser Anleitung gilt als bestimmungsgem er Gebrauch Diese Anleitung beschreibt Anschluss Gebrauch und Pflege des Mikrowellen Messger ts LMA3xxPA PMD3xxPA Lesen Sie diese Anleitung bevor Sie das Ger t anschlie en und betreiben Die Anleitung ist Teil des Produkts und muss griffbereit in der N he des Ger ts aufbewahrt werden Beeintr chtigung der Sicherheit Dieses Ger t ist gem EN 61 010 Sicherheitsbestimmungen f r elektronische Messger te gebaut gepr ft und hat das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen Wenn anzunehmen ist dass das Ger t nicht mehr gefahrlos betrieben werden kann so ist es au er Betrieb zu setzen und vor einer weiteren Inbetriebnahme durch Kennzeichnung zu sichern Die Sicherheit des Benutzers kann durch das Ger t beeintr chtigt sein wenn Messger t Sensor oder Zubeh rteile sichtbare Sch den aufweisen das Ger t nicht mehr wie vorgesehen arbeitet das Stromkabel oder der Stecker besch digt sind das Ger t heruntergefallen ist l ngere Zeit unter ungeeigneten Bedingungen gelagert wurde erschwerten Transportbedingungen ausgesetzt war oder lose Teile enth lt In Zweifelsf llen ist das Ger t grunds tzlich an den Hersteller zur Reparatur bzw Wartung einzu schicken Ver nderungen Ohne unsere Zustimmung durchgef hrte eigenm chtige Umbauten und Ver nderungen sind aus Si
216. ile Im Folgenden finden Sie eine Auflistung der Meldungen die vom Gerat in der Statuszeile Statuszeile Details auf Seite 208 ausgegeben werden Anzeige Statuszeile Ma nahme Sensor leer Messung l uft Ger t ist bereit zur Messung und wartet auf Bef llung Ger t versucht Messung durchzuf hren Falls kein Messwert angezeigt wird auf weitere Informationen warten Sensor leer Leerabgleich durchf hren Seite 210 Sensor halbvoll nur f r Bypass Messung Sensor scheint leer Folgende Ger teeinstellung pr fen Einstellung des F llstandsensors Makro Programmierung Ger teversion MW Wert Kalibration durchf hren In Betriebsart Messung wechseln Au er Bereich F r den Mikrowellenwert kann keine nicht lineare Kalibration berechnet werden da in dem Bereich kein g ltiger Wert vor handen ist HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz Fehlermeldungen Fehlermeldungen werden in der Statuszeile bzw im Display ausgegeben Im Display wird der Fehlercode durch ein vorangestelltes E gekennzeichnet in der Statuszeile der Software durch das jeweilige K rzel des Fehlerblocks MV bzw MWT RE MT Die sechsstelligen Fehlermeldungen bestehen aus drei Bl cken zu jeweils maximal 2 Ziffern e Block 1 gibt allgemeine Informationen zur Art des aufgetretenen Fehlers Der Fehlercode 2 weist auf MT Fehler hin die genaue Art de
217. ils on page 120 dialog Graphic Edit Extract The graph extract i e the slope of the regression line is transferred to the calibration as a meas uring point with a corresponding remark Graphic Settings Compression test properties Note The 1st display panel shows the most important compression test settings Press this field to display the Compression test properties dialog Ranges Here you determine the parameters for the measurement ranges in which measured values are recorded and for the measurement range indicating the empty sensor state HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Submit to sensor mode The sensor mode you selected is adapted to the test results Regression Scale Graph Type The parameters you set here adjust the depiction of the graph Graphic Print You can print the graphical depiction of the measured values See page 53 for information on how to connect a printer The graph is printed as it appears on the screen Measurement Note The 2nd display panel shows the measurement settings for the compression test Press this field to open the Measurement settings dialog Use this dialog to define the measurement procedure continuously Activate this option if you want to continuously record values for the compression test process measurement devices Measurements are then taken every second Deactivate this option if you
218. in die Probe ein Die Messung wird vom Ger t durchgef hrt Bei gleichzeitiger Temperaturmessung wird die Messung dann durchgef hrt wenn ein kon stanter Temperaturwert gemessen wird O Hinweis Bei der Messung eines Referenzwertes werden sowohl Feuchte wie auch Dichte gemessen Trotzdem muss die Kalibration f r jede Messgr e getrennt durchgef hrt werden SHE sartorius 173 seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA Kalibrieren 11 13 2 VG 14 15 16 17 18 19 SP 21 174 Je nach genutztem Sensor und den Einstellungen des Systems werden Sie aufgefordert die Probe zu drehen oder eine neue Probe in den Sensor zu geben F hren Sie dann die Schritte 8 bis 10 erneut durch Dr cken Sie Speichern Der Dialog zur Eingabe einer Bemerkung wird angezeigt Hier geben Sie z B die Nummer der Probe ein Dann dr cken Sie auf bernehmen Anschlie end erhalten Sie den Dialog zur Eingabe der Referenzwerte Die weitere Vorgehens weise ist davon abh ngig ob Sie Proben mit bereits vorliegenden Referenzwerten verwendet haben oder ob die Proben jetzt zum Ermitteln der Referenzwerte an Ihr Labor geschickt werden M glichkeit 1 Die Referenzwerte liegen vor Geben Sie den Referenzwert der Probe ein und dr cken Sie die bernehmen Schaltfl che gr nes H kchen Der Messwert wird in der Tabelle angezeigt Hinweis Auch wenn f r eine Probe mehrere Messungen durchgef hrt werden
219. inuously displayed as the last determined value The cursor is positioned on the last visible row Press the control a second time to end the continuous display of the last deter mined value Navigation and cursor position The navigation controls move the cursor to a new position They do not highlight or select a value Navigation and sorting of tables The start and end of a table are defined by its sorting With ascending sorting sorting arrow points upwards the start of the table corresponds to the smallest value in the column which is sorted With descending sorting the start of the table corresponds to the greatest value HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 13 4 View Help Ge Shows the Help menu History Eu If the menu is not open the History control is displayed Press this control to dis History play the most recently used menu items and to call them up if required Press the control a second time to hide the list again Back If the menu is open the Back control is displayed instead of the History control Press this control to hide the top menu level Measurement The menu items in the Measurement menu allow you to choose a product and display the meas ured values Menu items Product choice Table Graph Values 1st display 2nd display Options Product choice You call up the product choice dialog using the menu or by pressing the
220. ion Device does not start Check power supply Turn on the device Not all described menus availa Log on with other user rights ble No ongoing measurements are Start measurement process page 45 displayed Modify the view the measured values may be outside the dis played range Check sensor connection cables o4 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA 13 Operator Interface Reference This chapter describes the user interface touch screen of the TMV software There is an expla nation for every menu item and all dialogs In the preceding chapters reference is made to these at the corresponding points These details are also provided in the online help The operator interface is divided into several sections View Status line controls Menu M Moisture 7 30 Density 5 12 mg cm R B lt pos Hep Se Mode easurement casar cusar f Product Of moisture zax D a Display panel roduc tuifee AD 7 0000 7 00 Moisture 10 00 3 00 7 1 2 j Offset moisture No Date Time Remark Moisture Density Temp 14 14 2007 04 13 1414 04 REMARK14 7 31 514 26 3 15 15 2007 04 13 14 14 06 REMARK 15 7 28 5 14 26 3 16 16 2007 04 13 141409 REMARK 16 725 511 26 3 17 17 2007 04 13 141411 REMARKI7 7 24 5 11 23 Display panel 18 18 2007 04 13 141413 REMARK 18 731 for table gra
221. ion The dialog for the simple calculation of the calibration page 91 appears EE sartorius a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference sartorius SE Options Moisture value min range Specify the minimum difference between two values for those values to be valid for the calibra tion Separate minimum differences are set for the measured calibration value reference value correction value and temperature correction value You can also call up this dialog by pressing the 2nd display panel correlation standard devia tion values Automatically calculate x Activated The curve is automatically recalculated each time the calibration values change g Deactivated You have to click the 1st display panel again to recalculate the curve Deactivate this option if you still need to carry out considerable value editing You are then able to work more quickly since the calculation process always requires a certain amount of time If individual values are removed or changed it may mean that the curve can no longer be calculated If this is the case the system issues an error message With limits x Activated The limits of the non linear zones are recalculated for every change g Deactivated The limits of the non linear zones are maintained when changes occur Optimized manual correction x Activated Measured temperatures are taken into account g Deactiva
222. ionspunkte aus der Kalibration entfernen ohne diese zu l schen Dazu weisen Sie dem Punkt unter Typ die Eigenschaft nicht g ltig zu 2 Seite 227 Dieser Wert wird f r die Kalibration nicht ber cksichtigt Hinweis Sie k nnen bei einer guten Kalibration die Sie bereits gespeichert haben alle Einzel werte l schen um Speicherplatz im Ger t freizugeben Die Kalibration bleibt erhalten Kopieren Einzelne Werte der Kalibration k nnen kopiert werden W hlen Sie im Men Kalibration gt Feuchte Kalibration gt Tabelle gt Bearbeiten gt Kopieren Die Tabelle wird nun im Modus zum Kopieren angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen gt Seite 210 zum Markieren einer oder mehrerer Zeilen Kopierte Eintr ge werden wahlweise zu den Kalibrationsdaten eines Produktes oder zu den Einstellungen f r den Verdichtungstest kopiert Markieren Sie entweder einen Eintrag einen Block oder alle Eintr ge Um mehrere Zeilen zu markieren dr cken Sie auf die Schaltfl che Mehrere W hlen Sie nun mithilfe der Schaltfl che Block 1 Block 2 mehrere Werte aus oder markieren Sie einzelne Eintr ge Dr cken Sie auf Kopieren W hlen Sie im Dialog Kopieren nach ein Produkt HE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz 4 W hlen Sie ob die markierten Werte in die Kalibration des Produktes oder zum Verdichtungs test kopiert werden sollen Es werden nur
223. isk of injury due to burning The surface may be hot EE sartorius S mechatronics WLM6009 a10081 LMA316PA LMA321PA Safety instructions 10 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA 3 Product description The system consists of a microprocessor controlled evaluation unit the moisture measuring system and one or two sensors which are each connected to the evaluation unit with two micro wave cables When using newer sensor types Black Line series an additional connection with a data cable is also required D page 24 The microwave measuring devices are available as bench top versions for use in the laboratory LMA321PA LMA316PA and as wall mounted units for measurements in production facilities PMD320PA PMD325PA The microwave measuring device functions according to a high precision resonator measuring procedure During a measurement both the resonance frequency and the half width of the reso nance curve are measured Both of these variables are strongly influenced by the moisture content and density of the sample material A patented evaluation algorithm enables compensa tion of the density influence thus resulting in a moisture measurement that is independent of density In the laboratory the product is placed directly in the cavity sensor or fork sensor or in direct contact with a planar sensor Usually this does not require any pre processing of the products i e the products c
224. ith the appro priate rights HE sartorius coe mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference The following controls are used for instance when editing a table or setting product parameters Different controls are available depending on the type of editing taking place Edit Opens the corresponding dialog for editing the selected table row s Print This control is available when one or more rows in a table are selected for print ing See page 53 for information on how to connect a printer Delete Selected entries are deleted Copy Selected entries are copied and inserted again In some tables once the copy action has taken place you are asked to select the table into which you want the entries to be inserted Remarks Adds a comment to the selected items Statistics Statistics are created for the selected entries You can then display the statistics by choosing 1st display 2nd display Details on page 81 You can edit parameters for several values at the same time Multi Enables the editing of multiple values au Cie fC Al Entries are selected using the following controls or are selected individually by pressing a table row Block 1 Block 2 Select a row by clicking it Press this button to define the start of a block The row is highlighted in yellow The button is displayed as pressed with the name Block 2 Select another row by clicking it Press this bu
225. k or all entries To select several rows press Multi Now select several values using the Block 1 Block 2 control or select entries individually Press Copy Select a product from the Copy to dialog Specify whether the selected values are to be copied to the calibration of the product or the com pression test Only the measured values are copied not the reference values Press Close The copy process is complete New The Calibration properties dialog appears You create a new entry in the calibration table independently of the measured values Every value can be entered via this dialog Press an input field to display the Numerical input Details on page 125 or Text input Details on page 124 dialog Press Apply to insert the entry into the table HE sartorius seg x mechatronics O WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Example A value has been deleted by mistake and must be entered manually Values from another calibration are adopted to enable a comparison Table gt Settings The Settings dialog appears You can modify the table of calibration results to suit your personal needs See Settings for tables Details on page 126 Table gt Print Selected calibration values can be printed out Select Measurement gt Calibration gt Table gt Print The table is now displayed in print mode i e controls page 70 for selecting one or more rows are displayed at the bo
226. ken Sie auf Kopieren Markierte Werte werden kopiert und als neue Werte in die Tabelle eingef gt Dr cken Sie auf Schlie en Der Kopier Modus ist beendet Neu W hlen Sie im Men Produkteinstellungen gt Bearbeiten gt Neu Sie erhalten den Dialog Produkteigenschaften Dr cken Sie auf ein Eingabefeld Sie erhalten den Dialog zur Zahleneingabe Details auf Seite 268 bzw zur Texteingabe Details auf Seite 267 Machen Sie folgende Angaben Allgemein e Nr F r jedes Produkt vergeben Sie eine eindeutige frei w hlbare Kennnummer Kal Nr Wenn f r das Produkt eine eigene Kalibration durchgef hrt wird dann w hlen Sie hier selbst Wenn auf die Kalibration eines hnlichen Produktes referenziert wird dann w hlen Sie hier die Kennnummer des Produktes e Name Geben Sie einen Produknamen ein der eine eindeutige Zuordnung zum Produkt erm glicht e Bemerkung Geben Sie gegebenenfalls eine Bemerkung ein die bei der Zuordnung des Produkts sp ter hilfreich ist SHE sartorius 245 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz Sensormodus W hlen Sie hier den Sensor und den entsprechenden Modus mit dem das Produkt gemessen wird Das Ger t erkennt automatisch die Sensormodi der meisten Sensoren wenn diese ent sprechend angeschlossen sind O Hinweis Wenn f r einen Sensor mehrere Resonanzmodi zur Verf gung stehen gelten folgende Regeln Trockenes Produkt kleine Frequenz Ge
227. ken Sie auf eine Zeile um einen Benutzer zu markieren Neu Sie erhalten den Dialog zum Anlegen eines neuen Benutzers Seite 258 Bearbeiten Sie erhalten den Dialog zum ndern der Einstellungen f r den zuvor markierten Benutzer Seite 258 L schen Der markierte Benutzer wird gel scht Hinweis Es muss mindestens ein Benutzer mit Rechten der Stufe 5 verbleiben Der aktuelle Standardbenutzer kann nicht gel scht werden bernehmen Alle vorgenommenen nderungen werden gespeichert Die Benutzerkonfiguration wird geschlossen Abbruch Die Benutzerkonfiguration wird beendet ohne dass die nderungen bernommen werden Benutzereinstellungen Nutzername Dieser Name wird vom Benutzer bei der Anmeldung im Anmeldedialog eingegeben Nachname Vorname Diese Eintrage ordnen den Benutzernamen einer Person zu Passworteingabe Das Passwort das der Benutzer bei der Anmeldung angeben muss HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz Passwortwiederholung Um Eingabefehler zu vermeiden geben Sie das Passwort ein zweites Mal ein Benutzerebene Wahlen Sie eine der vorgegebenen Stufen Benutzerrechte sind in sechs Schritten abgestuft Die Rechte einer Stufe beinhalten jeweils auch die Rechte der niedrigeren Stufen Die niedrigste Stufe 0 erlaubt lediglich das Messen die h chste Stufe 5 bietet Zugriff auf alle Einstellungen Men punkte f r die ein Ben
228. ken Sie diese Schaltfl che um die zuletzt aufgerufenen Men punkte ange zeigt zu bekommen und diese gegebenenfalls aufzurufen Dr cken Sie die Schaltfl che ein zweites Mal um die Liste wieder auszublenden Zur ck lt Wenn das Men ge ffnet ist wird statt der Schaltfl che Chronik die Schaltfl che Zur ck eingeblendet Dr cken Sie auf diese Schaltfl che um die oberste Men ebene auszublenden 13 4 Messung Die Men punkte des Men s Messung erlauben die Auswahl des Produktes und die Anzeige der Messwerte Men punkte Produktauswahl Tabelle Grafik Werte 1 Anzeige 2 Anzeige Optionen SHE sartorius 213 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz Produktauswahl Den Dialog zur Produktauswahl erhalten Sie Uber das Ment oder indem Sie auf den Produkt namen drucken Produktauswahl ana 7 Senanung Tansi Anze Tr Vena 1 Coffee TEWS Elektr selbst 2 Coffee TEWS Elektr 3 Cigarett 41 REFER Verweis auf Kalibration KA ES d W a a A E gt Er bernehmen Abbruch Zum Anfang Seite zur ck Zur ck Sprung vor Seite H Produkte sind bereits angelegt Das hei t dass f r das Produkt die entsprechende Kalibration durchgef hrt wurde Die Daten des Sensors der f r die Messung genutzt wird sind Teil der Produkteinstellungen Produkte werden ber den Men punkt Produkteinstellungen Details auf Seite 244 neu ange
229. l In order to prevent malfunctions and damage to the measuring system or in production this system must only be operated by appropriately qualified trained personnel The operator of the instrument is responsible for ensuring that the appropriate training is provided for example for new personnel The operating personnel must have read and understood the operating instruc tions Warnings DANGER Risk of death by electric shock The measuring device must not be immersed in or come into contact with water or any other liquids Do not place receptacles filled with liquid such as cups of coffee on the measuring de vice Electric shock hazard Remove the plug of the measuring instrument from the mains if you intend to not use the measuring instrument for longer periods of time before cleaning the device before packing away or repositioning the device when working on the measuring device e g attaching peripherals or chang ing fuses if there is an obvious malfunction during operation in the event of a storm Always pull out at the plug not at the cable Caution material damage Ensure that there is sufficient distance from sources of heat such as heating plates heater pipes etc Do not use aggressive chemical substances scouring material hard sponges or similar for cleaning The touch screen surface is very sensitive You must only touch this with your fingers or specially designed pens Do not use pens screwdri
230. l keyboard If you are not using the touchscreen to operate the device and are using a keyboard instead you can deactivate the virtual keyboard to make the device easier to control As a result a simple input field is shown when you need to enter values or text e g remarks and you enter numbers or letters directly using the connected keyboard 1 Choose System settings gt Global settings and open the Settings 2 tab 2 Deactivate the Virtual keyboard option Restart the programme to activate the changes O Note The instructions in this manual refer to operating the device with the touch screen The only difference is that you press a control or menu item on the touchscreen whereas you click elements when using a mouse and keyboard 2 sartorius ey seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA Startup 28 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA 6 Calibration 6 1 Sartorius A one off calibration must be carried out for each product for which moisture or density is to be measured The measurement procedure is an indirect procedure It returns a value which is set by means of the calibration process in relation to actual values which have to be determined in a laboratory analysis What must be taken into account when calibrating Condition of samples The samples which are used for calibration should be in the same condition as when measure ment takes place Calibration
231. l of its electrical and electronic products These products may not be placed in household waste or brought to collection centres run by local public disposal operations not even if you are a small business For disposal in Germany and in the other member nations of the European Economic Area EEA please contact our service technicians in your local area or our service centre in Goettingen Germany Sartorius AG Weender Landstrasse 94 108 37075 Goettingen Germany In countries that are not members of the European Economic Area EEA or where no Sartorius subsidiaries or dealerships are located please contact your local authorities or a commercial disposal operator Prior to the disposal and or scrapping of the equipment any batteries should be removed and disposed of at a collection point Sartorius AG does not take back equipment contaminated with hazardous materials ABC contamination either for repair or disposal Please refer to the accompanying leaflet manual or visit our Internet site www sartorius com for comprehensive information including the service addresses to use if you plan to send your equip ment in for repairs or proper disposal HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Technical data 11 Technical data Power supply 110 230 V AC 50 60 Hz Power consumption 60 VA Fuses Two 2 AT fuses 250 V AC 5 x 20 mm Ambient temperature 0 45 C Data interfaces 2 x RS 232
232. lche Aktion ausgef hrt wird wenn Sie auf den Kopf einer Spalte dr cken 7 Sortierbar Die Tabelle wird nach der Spalte sortiert Sie ndern die Sortierfolge indem Sie wiederholt auf den Spaltenkopf dr cken Die aktuelle Sortierung wird durch den Sortierpfeil der im Spaltenkopf angezeigt wird verdeutlicht Beweglich Spalten werden verschoben indem Sie auf den Spaltenkopf dr cken und dann die Spalte an eine neue Position ziehen Profile Die Einstellungen f r die Anzeige der Tabelle sind als Standardprofil gespeichert Sie k nnen Ihre eigenen Einstellungen in einem von drei weiteren Profilen speichern Dr cken Sie auf das Listenfeld W hlen Sie eines der Profile aus Dr cken Sie auf Speichern um die Einstellungen in dem gew hlten Profil zu speichern Das Standardprofil kann nicht berschrieben werden Dr cken Sie auf Wiederherstellen um die Einstellungen aus einem der Profile wiederherzustel len Dr cken Sie bernehmen Die Tabelle wird den Einstellungen entsprechend angezeigt Hinweis Sie k nnen die Breite einer Spalte ndern indem Sie direkt auf die Trennlinie zwischen zwei Spaltenk pfen dr cken und dann die Trennlinie nach rechts oder links bewegen Sartorius 269 mechatronics WLM6009 a10081 13 12 270 Meldungen LMA316PA LMA321PA Bedienoberfl che Referenz Meldungen in der Statuszeile Details auf Seite 270 Fehlermeldungen Details auf Seite 271 Meldungen in der Statusze
233. learn more about the program s features and functions Software updates If your PC already hosts an earlier version of TMV there will be no language selection option step 3 and the installer will automatically run in the language it was previously set to If you do not change folders during the installation step 5 the installer will automatically over write the previous version with the updated data Links will always point to the last installed ver sion Generally the settings of the earlier version are maintained If you find that TMV will not connect to the measuring device after start check the IP address settings Uninstalling the software To remove TMV from your PC you can run the uninstaller belonging to the TMV package 1 Pick Start gt Programs gt TMV gt Uninstall from the menu EE sartorius 1 Ha mechatronics WLM6009 a10081 LMA316PA LMA321PA Control via external PC 4 3 20 Check the folder shown on the uninstaller s splash screen If you find that it points to the version of TMV you wish to remove click on Uninstall The application will be removed from the PC without further prompts Notes on operating TMV Operating TMV on a PC is only slightly different from operating it via touchscreen HMI as is described in this manual Instead of the virtual on screen keyboard you are provided with input fields in which you directly input the data using the PC keyboard When exporting data and
234. legt O Hinweis Das aktuell gew hlte Produkt ist in der Spalte Nr mit einem gr nen H kchen markiert 1 Dr cken Sie auf einen Spaltenkopf um die Tabelle zu sortieren Die aktuelle Sortierung wird durch einen Pfeil in einem Spaltenkopf angezeigt 2 Dr cken Sie auf die Zeile mit dem Namen des Produktes das gemessen werden soll O Hinweis Produkte mit hnlichen Eigenschaften k nnen dieselbe Kalibration referenzieren Falls ein Produkt die Kalibration eines hnlichen Produktes referenziert finden Sie dazu Informationen in der Zeile Verweis auf Kalibration Bei Produkten mit eigener Kalibration wird in der Spalte Kal Verweis der Hinweis selbst angezeigt O Hinweis Falls nicht alle Produkte angezeigt werden nutzen Sie die Schaltfl chen f r die Navigation Details auf Seite 212 VG 3 Dr cken Sie bernehmen Die Messung erfolgt nun f r das gew hlte Produkt Tabelle Die Anzeige der Messwerte wird in einer Tabelle dargestellt 1 Dr cken Sie auf einen Spaltenkopf um die Tabelle zu sortieren Die aktuelle Sortierung wird durch einen Pfeil in einem Spaltenkopf angezeigt 214 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz O Hinweis Die erste Spalte ohne Titel zeigt die Zeilennummer Position abh ngig von der Sortierung an Die Spalte Nr zeigt die automatisch vergebene laufende Nummer f r den Messwert an O Hinweis Die Anzeige der Tabelle kann ber Messung g
235. lesen nicht automatisch beim Starten der Ger te erfolgt ist oder die Sensormodi erneut eingelesen werden sollen Kommunikation MW Gerate Wenn Sie das Gerat Uber einen PC mithilfe von TMV steuern wollen dann legen Sie hier den entsprechenden Eintrag f r das Ger t an Seite 255 und verbinden den PC mit dem Ger t Eine Beschreibung der Vorgehensweise finden Sie auf Seite 163 Bearbeiten Werte Dr cken Sie auf eine Zeile um diese zu markieren Dr cken Sie auf die Schaltfl che zum Bearbeiten Sie erhalten den Dialog Ger teeigenschaften Geben Sie hier IP Adresse und weitere Daten zur Netzwerkverbindung ein Klicken Sie w hrend Sie am PC arbeiten auf Verbinden um das Ger t und den PC ber das IP Netzwerk zu verbinden Dr cken Sie auf bernehmen um die Werte zu bernehmen Dr cken Sie auf Schlie en Das Bearbeiten der Werte ist beendet L schen Ein Ger t kann aus der Liste gel scht werden W hlen Sie im Men Bearbeiten gt L schen Die Tabelle wird nun im Modus zum L schen angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen Seite 210 zum Markieren einer oder mehrerer Zeilen Dr cken Sie auf eine Zeile Das Ger t ist markiert Dr cken Sie auf L schen Das Ger t wird aus der Liste gel scht Dr cken Sie auf Schlie en Der L sch Modus ist beendet Kopieren Der Eintrag f r ein Ger t kann kopiert werden Kopierte Eintr ge werden in der Tabelle wieder eingef gt
236. lick the graphic and move it by dragging it with the Q mouse button held down 4 Ifno graph is displayed due to the settings choose auto in Graphic gt Settings SHE sartorius gt e HO mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Temp correction of temperature If a temperature correction has been set for the calibration gt page 91 a slider control and an input field labelled Temp are shown above the graphic 1 You can now manually change the temperature correction values here in one of the following ways Moving the slide control Manually entering a value Pressing the arrow fields The curves delimiting the correction range are moved on the chart Graphic gt Settings You can display a larger or smaller view of the chart To call up the dialog for the settings described below click on one of the two axes in the graphical depiction auto 1 Select this box to enable the automatic adjustment of the view x Activated The values for the X and Y axes are automatically adjusted The zoom factor is set to 100 g Deactivated Enter the values yourself Zoom 2 Enter any value between 1 and 400 X axis Y axis 3 Enter the lowest Min and highest Max value for the display area Activate temperature density correction reference lines Activate O Note You can activate temperature or density correction x Activated Measurement results are correct
237. lle 153 153 2007 01 31 10 06 38 BEMERKU 712 3 31 25 s mit Messwerten 154 154 2007 01 31 10 06 40 BEMERKU 711 3 32 255 155 155 2007 01 31 10 06 42 BEMERKU 718 3 32 25 6 bzw Anzeige der 156 156 2007 01 31 10 06 44 BEMERKU 715 3 35 25 e Messwerte 157 157 2007 01 31 10 06 46 BEMERKU 718 3 34 25 6 158 158 2007 01 31 10 06 48 BEMERKU 7 15 3 34 25 6 Messung e starten x I lt K lt v gt gt pl Navigation Start Stopp Zum Anfang Seite zur ck Zur c Sprung Yor Seite vor aum Ende stoppen Messwert speichern ACHTUNG Ber hren Sie die Schaltfl chen auf dem Touchscreen direkt mit dem Finger IN oder speziell daf r vorgesehenen Stiften Verwenden Sie keine spitzen Gegenst nde wie Schraubenzieher Kugelschreiber o A Diese k nnen die Oberfl che besch digen SHE sartorius 185 seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Kurzanleitung Messen Kurzanleitung Messen 2 3 4 CO 6 7 10 186 IC Ger t starten Schalten Sie das Ger t mit dem Ein Ausschalter auf der R ckseite ein Die Software des Ger ts startet automatisch der Bildschirm wird dabei zwischenzeitlich schwarz Sobald das Ger t betriebsbereit ist wird die Bedienoberfl che angezeigt Unter Umst nden werden Sie aufgefordert sich anzumelden Geben Sie dann Ihren Nutzerna men und Ihr Passwort ein und dr cken Sie bernehmen Empfehlung Warten Sie nach dem Ein
238. llt werden Die Korrektur kann manuell angepasst werden Wird diese Option f r Temperatur bzw Dichte aktiviert so haben Sie auch in der grafischen Darstellung der Kalibrationskurve die M glichkeit die Korrektur mittels Schieberegler oder Zahleneingabe vorzunehmen Ergebnisse Auf der rechten Seite des Dialoges werden die aus den von ihnen gemachten Einstellungen resultierenden Ergebnisse angezeigt Diese Felder k nnen nicht editiert werden Falls die Kalibration sich mit diesen Parametern nicht berechnen l sst wird ein Hinweis im unteren Teil des Feldes Ergebnisse rot angezeigt Dr cken Sie auf Kalibrationen um sich eine Auflistung aller m glichen Kalibrationen anzeigen zu lassen Die Auflistung wird in demselben Dialog auf der zweiten Registerkarte Kalibrationen angezeigt Die Auflistung der Kalibrationen kann zum Zweck der bersichtlichkeit gefiltert werden Dr cken Sie dazu auf das Listenfeld Alle Kalibrationen und w hlen Sie einen Filter aus Dr cken Sie auf einen Eintrag um diesen zu markieren Dr cken Sie auf Auswahl um diese Parameter f r die Kalibration zu bernehmen Dr cken Sie auf Zeigen um zur grafischen Darstellung bzw zur Tabellenansicht zur ckzu kehren Dr cken Sie in der grafischen Darstellung bzw in der Tabellenansicht auf Speichern um die Kali bration zu speichern oder kehren Sie wieder zum Dialog mit den Experteneinstellungen zur ck RE sartorius 233 mechatronics WLM6009 a10081 LMA
239. ls auf Seite 164 Installieren Sie TMV auf dem PC siehe Seite 159 Starten Sie TMV auf dem PC Klicken Sie auf die Schaltfl che mit dem Haus Symbol und w hlen Sie den Befehl Systemein stell gt Konfiguration gt Kommunikation gt MW Ger te a 16 Erstellen Sie einen neuen Eintrag f r ein Ger t ber den Befehl Systemeinstell gt Konfigura tion gt Kommunikation gt MW Ger te gt Bearbeiten gt Neu W hlen Sie als Typ MWAxxx Wahlen Sie als Schnittstelle TCP IP Geben Sie die IP Adresse des Messger ts ein zs As 7 Klicken Sie auf Verbinden SHE sartorius 163 mechatronics WLM6009 a10081 LMA316PA LMA321PA Steuerung Uber externen PC 164 Mehrere Messgerate Uber einen PC steuern Falls Sie mehrere Messger te Uber diesen PC steuern wollen m ssen Sie f r jedes Ger t einen entsprechenden Eintrag anlegen Den Messger ten m ssen daf r unterschiedliche IP Adressen zugewiesen werden siehe IP Adresse des Messger ts ndern Details auf Seite 164 Sie k nnen dann die Software TMV mehrfach starten und jeweils mit einem anderen Messger t verbinden sodass Sie parallel an allen Messger ten arbeiten k nnen IP Adresse des Messger ts ermitteln Die IP Adresse k nnen Sie am Messger t auf folgende Weise ermitteln W hlen Sie am Messger t Systemeinstell gt Konfiguration gt Kommunikation gt Dieses TMV Der Dialog Dieses TMV f r dieses Messger t wird angezeigt und Sie k nnen die IP Adresse im
240. lt O Hinweis Beachten Sie dass Sie f r einen komplexeren Kalibrationstyp entsprechend mehr Messwerte ben tigen Extremum e F r den Kalibrationstyp nichtlinear bestimmen sie hier ob ein Extremum in der Kurve vorkommt Markieren Sie die Option Extremum wenn Sie wissen dass einer der Werte einen Hoch bzw Tiefpunkt darstellt x Kurve mit Extremwert U Kurve ohne Extremwert A Korrektur W hlen Sie hier ob und wie eine Korrektur f r die Kalibrationskurve erfolgen soll Die Kalibration ber cksichtigt dann Schwankungen von Temperatur und oder Feuchte der Proben in der gew hlten Form Falls nicht genug Messwerte vorliegen um eine sinnvolle Korrektur durchf hren zu k nnen erhalten Sie eine entsprechende Meldung SHE sartorius 241 seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz SA en DIN 242 Hinweis Die Ber cksichtigung von Temperatur und oder Dichte setzt voraus dass entspre chende Werte f r die Proben vorliegen Die Temperatur soll in der Regel bei Temperaturschwankungen von ber 5 C ber cksichtigt werden Dr cken Sie auf bernehmen um die Einstellung zu bernehmen und die Kalibration zu berechnen Nach erfolgreicher Berechnung der Kalibration werden die Parameter im Feld 1 Anzeige 2 Anzeige angezeigt Dr cken Sie auf Experte um alle Einstellungen manuell vorzunehmen Dr cken Sie auf Auto um die Kalibrationskurve anhand der gew
241. lten Mit anderen Benutzerrechten anmelden Men s verf gbar Laufende Messwerte werden nicht angezeigt Messung starten Seite 181 Anzeige anpassen eventuell liegen die gemessenen Werte au erhalb des angezeigten Bereichs Verbindungskabel der Sensoren pr fen HE sartorius mechatronics 193 WLM6009 a10081 LMA316PA LMA321PA Abhilfe bei Problemen 194 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA 12 Weitere Funktionen 12 1 Benutzer mit unterschiedlichen Zugriffsrechten einrichten F r die Nutzung des Ger ts k nnen verschiedene Benutzer mit unterschiedlichen Zugriffs rechten angelegt werden Auf diese Weise ist es m glich den Zugriff auf Einstellungen und einzelne Aufgaben z B Kalibration harter Leerabgleich stufenweise einzuschr nken und so bestimmte Funktionen nur qualifiziertem Personal zug nglich zu machen Ein Benutzer kann als Standardbenutzer festgelegt werden Ist dies der Fall so startet das Ger t automatisch nach dem Anschalten mit den Rechten dieses Benutzers ohne Passwort Abfrage unabh ngig davon welcher Benutzer vor dem letzen Ausschalten angemeldet war Wenn kein Standardbenutzer definiert ist werden Sie immer direkt nach dem Starten der Software aufgefor dert sich anzumelden Benutzerrechte sind in sechs Schritten abgestuft Die Rechte einer Stufe beinhalten jeweils auch die Rechte der niedrigeren Stufen Die niedrigste Stufe 0 erlaubt ledigl
242. lue You can display the moisture or density in this way The statistical value is displayed for all stored measured values However you can select indi vidual positions in the table and generate a statistical value for these measured values only See Statistics Details on page 77 The following are displayed Whether the statistical value applies to moisture or density and how many positions were used to generate the statistical value The arithmetic mean average The standard deviation RMS Settings You call up this dialog from the menu or by pressing one of the display panels Value 1 Press the list field and specify whether the statistics are to be displayed for moisture or density 2 Press Analogue to display values in the display panel See Analogue display 3 Press Apply The values are displayed in accordance with the selected settings Options If you select a product for which a large number of measured values have already been stored in the device it might take a few minutes for these values to be retrieved 1 Select the number of values to be retrieved when the device is initialized auto All values stored in the device are retrieved The number of values which can be stored for a product is defined in the product properties page 103 When a process measurement is started the remaining values are retrieved in the background so that the interface and gauge are synchronized again HE sarto
243. meinstellungen Dieses Ment bietet Zugang zu Parametern die das System beeinflussen Das Men hat folgende Men punkte Datum und Zeit Details auf Seite 248 Globale Einstellungen Details auf Seite 249 Konfiguration Details auf Seite 251 Makroeinstellung Details auf Seite 260 Datum und Zeit System Datum und System Zeit des Ger tes k nnen angepasst werden Achtung Wenn Sie die Systemzeit verstellen entspricht die angegebene zeitliche Abfolge IN von Messwerten unter Umst nden nicht mehr der tats chlichen Reihenfolge 1 W hlen Sie Systemparameter gt Datum und Zeit Sie sehen den Dialog Datum und Zeit N Dr cken Sie auf das Listenfeld neben dem Datum Sie erhalten eine Kalenderanzeige W hlen Sie hier Tag Monat und Jahr Dr cken Sie auf das Feld mit der Zeitangabe um die Systemzeit einzustellen 3 4 Dr cken Sie auf das Listenfeld Zeitzone 5 W hlen Sie die Zeitzone in der sich das Ger t befindet 6 Automatische Sommerzeit Gegebenenfalls aktivieren Sie die automatische Anzeige der Sommerzeit indem Sie auf das K stchen dr cken ae Option aktiviert Sommerzeit wird automatisch angezeigt m Option deaktiviert Sommerzeit wird nicht angezeigt Die Anzeige wird f r alle Tabellen und Ansichten umgestellt 248 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz Globale Einstellungen Das Men hat folgende Men punkte Ansicht
244. mperature SENSOR un te ee een 109 Temperature correction enn 90 99 TME en aa A S 107 Touchscreen 65 Type Calibration 91 100 Calibration point 86 95 Symbol 87 95 Vald zarten 86 95 U USB Bel ECHT 55 User Greate ea 69 oe eb he bee ea 50 116 Delega A En 50 Edit Zafra ea 116 Rights ae Deren 30 V Version number ccccceeeseeceeeeeaneeeeeeeeesaaeeenes 121 View Graph a aoia arada 00002 en 77 Profiles 22220 126 Readings 80 leede ee ern 74 Virtual keyboard unerssnneeenessnnnnnnnnnnnnnnnn nn 27 Z SEET 89 98 HE sartorius mechatronics WLM6009 a10081 1 1 1 2 1 3 1 4 1 5 2 1 2 2 2 3 2 4 2 5 2 6 3 1 3 2 3 3 4 1 4 2 4 3 4 4 4 5 4 6 5 1 5 2 5 3 6 2 6 3 6 4 6 5 7 1 72 Bevor Sie beginnen bersicht ber die Dokumentation Andere Dokumentationen Anwendungsberatung Hinweise zur Online Hilfe Schreibkonventionen in dieser Dokumentation Sicherheitshinweise Bestimmungsgem er Gebrauch Beeintr chtigung der Sicherheit Ver nderungen Installation und Wartung Qualifikation des Bedienpersonals Gefahrenhinweise Produktbeschreibung Ger teansicht Vorderseite Ger teansicht Anschl sse auf der R ckseite Lieferumfang Inbetriebnahme Hinweise zum Aufstellen Anschlie en bersicht ber den Arbeitsablauf LMA321PA starten LMA321PA ausschalten Hinweise zur Bedienung der Software Steuerung be
245. n This will ensure that the operating temperature of the unit is perfect Taking measurements Pick Measurement from the menu unless the mode shown above the on screen table is Measu rement already Cursor Mod zu Measurement Mode Off moist Coffee Selected product 000 7 00 Moisture 10 0 Check ifthe line below the Mode box has the correct product To analyse another product open the menu choose Measurement gt Product choice and select a product To start measuring press the Start button Follow the instructions shown on the status line In case the sensor still contains any product you are prompted to Please empty the sensor Remove the product and put in an empty beaker Fillthe sensor as soon as Please fill is displayed and insert the Pt 100 temperature sensor if necessary The device performs the measurement and the measured value is displayed Save the result by pressing the Save control Depending on the sensor you are using or the system settings you made you may be asked to turn the sample or feed the sensor a new sample Repeat steps 6 to 8 The dialog for entering a remark is shown Enter the number of the sample for example then press Apply Printing measured values If a printer is connected you can output the analysis results to it Open the menu and choose Measurement gt Table gt Print Select the parts of the table you wish to print To print the entire table press All Press
246. n Laufwerk 6 Klicken Sie abschlie end auf Weiter 7 W hlen Sie nun das Verzeichnis f r die Programmverkn pfung aus ber diese Verkn pfung k nnen Sie TMV sp ter durch Klicken auf Start gt Programme starten Au erdem finden Sie in diesem Verzeichnis die Verkn pfungen zum Deinstallationsprogramm falls Sie TMV wieder von diesem PC entfernen m chten Klicken Sie abschlie end auf Weiter 8 Im n chsten Schritt legen Sie fest ob das Installationsprogramm auf dem Desktop Ihres PCs und oder in der Schnellstartleiste eine Verkn pfung erstellen soll ber die Sie TMV sp ter star ten k nnen und ob diese Einstellungen f r alle Benutzer des PCs gelten sollen oder nur f r den aktuell angemeldeten Benutzer 9 Klicken Sie auf Installieren TMV wird nun auf Ihrem PC installiert be a TMV Installation Bletz IUS Die Installation von TMY wird abgeschlossen TMY wurde auf Ihrem Computer installiert klicken Sie auf Fertig stellen um den Installations Assistenten zu schlie en sartor Ray ausf hren Eertig stellen 10 Im abschlie enden Dialog klicken Sie auf Fertig stellen Abbrechen O Hinweis Sind Messger t und PC bereits miteinander verbunden k nnen Sie Option TMV ausf hren aktivieren wenn Sie TMV gleich starten m chten z B wenn Sie lediglich ein Update auf eine fr here Version von TMV installiert haben oder als n chstes die IP Adresse in TMV einstellen wollen
247. n Sie auf Schlie en Die Eingabe ist beendet Bemerkung Sie erhalten den Dialog zur Texteingabe Details auf Seite 267 Der Text der Bemerkung kann frei gew hlt werden 1 Dr cken Sie auf bernehmen um den Eintrag in die Tabelle zu bernehmen O Hinweis Dieser Dialog erscheint nach jeder Messung eines Kalibrationswertes Hier geben Sie typischerweise die Nummer der Probe ein So k nnen Probe und Messwerte eindeutig zugeordnet werden Referenzfeuchte Sie erhalten den Dialog zur Zahleneingabe Details auf Seite 268 Geben Sie den Laborwert f r die Feuchte der Probe mit allen Nachkommastellen ein Die Anzeige erfolgt entsprechend den Einstellungen gerundet Dr cken Sie auf bernehmen um den Eintrag in die Tabelle zu bernehmen Dieser Dialog erscheint nach jeder Messung eines Kalibrationswertes Typ Sie haben die M glichkeit einzelne Punkte der Kalibrationskurve durch unterschiedliche Symbole darzustellen So lassen sich in der Kalibrationskurve z B Messungen die an unterschiedlichen Tagen gemacht wurden verdeutlichen 1 Dr cken Sie auf ein Eingabefeld und Sie erhalten den Dialog Typ 2 W hlen Sie ob der Kalibrationspunkt f r die Kalibration verwendet wird g ltig X Kalibrationspunkt ist g ltig und wird f r die Berechnung der Kalibrationskurve verwendet Der Wert wird f r die Kalibration nicht ber cksichtigt Der Eintrag in der Tabelle bleibt jedoch bestehen und kann gegebenenfalls sp ter
248. n Sie die Messung 4 Lesen Sie die Werte ab Start Messung starten Messung stoppen e o Der Vorgang der Messung unterscheidet sich je nach Einsatzart Einzelmessung festes Produkt im Labor Nach dem Leerabgleich wird das Produkt in oder auf den Sensor gegeben Die Messung wird gestartet Die gemessenen Werte Feuchte Dichte Temperatur werden angezeigt Mehrfachmessung Sch ttgut im Labor Nach dem Leerabgleich wird ein Messbeh lter in oder auf den Sensor verbracht Die Messung wird gestartet Gegebenenfalls wird die Lage des Messbeh lters z B durch Drehen ver ndert Die gemessenen Werte Feuchte Dichte Temperatur werden angezeigt Eine neue Messung wird initiiert Lesen Sie dazu Messung im Labor Details auf Seite 182 Anzeige der Werte Die gemessenen Werte werden mehrfach und in verschiedener Darstellung angezeigt Jede der Anzeigen kann den Bed rfnissen der Einsatzumgebung angepasst werden Verschiedene Anzeigem glichkeiten sind Tabelle Seite 214 Grafik gt Seite 218 und Wertanzeige 2 Seite 221 wahlweise f r Feuchte Dichte Temperatur analoge Darstellung des Wertes an der Cursorposition oder des markierten Wertes Seite 222 Statistik f r eine Messreihe Zur Einrichtung der Anzeigen lesen Sie bitte die entsprechenden Abschnitte im Kapitel Bedien oberfl che Referenz Details auf Seite 205 SHE sartorius 181 mechatronics WLM6009 a10081 LMA316PA
249. n im Handbuch Auf den Planarsensoren ist folgender Warnhinweis angebracht Vorsicht Verletzungsgefahr durch Verbrennung Die Oberfl che kann hei sein SHE sartorius 145 mechatronics WLM6009 a10081 LMA316PA LMA321PA Sicherheitshinweise 146 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA 3 Produktbeschreibung Das System besteht aus einer mikroprozessorgesteuerten Auswerteeinheit dem Mikrowellen Messgerat und bis zu zwei Sensoren die durch jeweils zwei Mikrowellenkabel mit der Auswer teeinheit verbunden sind Bei neueren Sensor Typen Black Line Serie ist die zusatzliche Verbindung mit einem Datenkabel notwendig 2 Seite 154 Die Mikrowellen Messger te sind sowohl als Tischger t f r den Einsatz im Labor LMA321PA LMA316PA wie auch zur Wandmontage f r die Messung in Produktionsanlagen PMD320PA PMD325PA erh ltlich Das Mikrowellen Messger t arbeitet nach einem hochpr zisen Resonator Messverfahren Im Verlauf einer Messung werden jeweils die Resonanzfrequenz und die Halbwertsbreite der Reso nanzkurve vermessen Diese beiden Gr en werden von der Feuchte und der Dichte des Probenmaterials stark beeinflusst Ein patentierter Auswertungsalgorithmus erlaubt die Kompen sation des Dichteeinflusses und somit eine dichteunabh ngige Feuchtemessung Im Labor wird das Produkt direkt in den Hohlraum oder Gabelsensor oder unmittelbar in Kontakt mit einem planaren Sensor gebracht Hier
250. n your PC the Export dialog appears Specify a storage location on the PC and change the name of the export file if necessary Note Microsoft Excel 2003 The widespread and universal csv export format cannot be properly interpreted for Excel 2003 Rename the csv file as txt and import it into Excel 2003 using the import function HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference ll S g 4 Statistics Statistics can be created for selected entries in the table Once you press Statistics corresponding buttons become available See Controls in Measurement Calibration Details on page 70 Select an entry a block or all entries The same remark is defined for all selected entries To select several rows press Multi Now select several values using the Block 1 Block 2 control or select entries individually Press Statistics Assuming that the corresponding settings have been made the statistics are depicted in one of the display panels at the top right of the screen See Statistics Details on page 83 to learn more about how to configure the display panels Press Close to return to the display Graph The measured values are depicted as a graph The graph visually illustrates extreme values and shows trends in the development of values You can choose whether to display the position or time of measurements on the horizontal axis X axis You can
251. nect a printer Choose Service gt MW test gt Compression test gt Table gt Print The table is now displayed in print mode i e controls for selecting one or more rows are dis played at the bottom Select highlight the lines you wish to print Press the Print control The selected rows are printed out Press Close The printing of the values is complete HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Calibration 6 5 Calibration Calibration is carried out separately for moisture and density However the procedure is the same Prerequisites You are logged in with at least level 3 user rights page 30 You have created the product gt page 30 The system is ready to take measurements sensor connected Samples of the product in the condition in which they are to be measured are available Distinguishing between measurement methods There are the following different types of measurement or calibration depending on the type of application Laboratory measurement Single measurement e g cigarette One measured value is determined for the calibration Multiple measurement procedure e g for bulk goods in graduated containers Several measured values are determined the graduated container must be rotated between measurements Process measurement during a production process Several measured values for which the corresponding samples of the product must be taken
252. ned references which are already configured when the device is delivered Inthe menu select Product settings gt Edit gt Delete The table is now displayed in delete mode i e the controls page 70 for selecting one or more rows are displayed at the bottom Press arow The product is selected Press Delete The product is deleted Press Close The deletion process is complete Copy You can copy a product entry Copied entries are inserted at the end of the table Copying an entry makes it easy to create similar entries Inthe menu select Product settings gt Edit gt Copy The table is now displayed in copy mode i e the controls gt page 70 for selecting one or more rows are displayed at the bottom Press a row The value is selected Press Copy Selected entries are copied and inserted into the table as new values Press Close The copy process is complete New In the menu select Product settings gt Edit gt Create The Product properties dialog appears Press an input field The Numerical input Details on page 125 or Text input Details on page 124 dialog appears Enter the following data General No Enter a freely selected ID number for each product Cal no If a separate calibration is carried out for the product choose self here If the calibration of a similar product is referenced select the ID number of the product in question Name Enter a product name which clearly i
253. nen Wert der Uber den Vorgang der Kalibrierung in Beziehung zu den tatsachlichen Werten gesetzt wird die durch eine Laboranalyse ermittelt werden m ssen 6 1 Was Sie beim Kalibrieren beachten m ssen Beschaffenheit der Proben Die Proben die zur Kalibration benutzt werden sollen in demselben Zustand vorliegen in dem diese zur Messung vorliegen Die zur Kalibration verwendeten Proben sollen bez glich der Feuchtewerte Uber den gesamten Feuchtebereich in dem sp ter gemessen wird verteilt liegen Es ist von Vorteil wenn die Feuch tewerte einzelner Proben sogar au erhalb des sp teren Messbereiches liegen Die Proben m ssen homogen durchfeuchtet sein M gliche Fehlerquellen bei der Kalibration Kalibrieren Sie in dem Feuchtebereich unter den Raumbedingungen unter denen Sie sp ter messen Die Temperatur der Proben soll w hrend der Kalibrierung und der sp teren Messung m glichst gleich sein Bei Schwankungen der Temperatur um 5 C ist keine Temperaturkompensation erforderlich Bei Abweichungen ber 5 C muss die Temperatur gemessen und ber cksichtigt werden Achten Sie darauf dass am Sensor kein Wasser kondensiert Gegebenenfalls wischen Sie Kon denswasser vorher mit einem trockenen Tuch ab Beim Arbeiten mit einem Messbecher achten Sie darauf dass der Messbecher nicht von au en feucht ist Nicht mit nassen H nden arbeiten Der Sensor bzw Messbecher muss vollst ndig gef llt sein Hinweise zum Ermit
254. ngabefeld Temp 1 Ver ndern Sie hier manuell die Temperaturkorrekturwerte indem Sie den Schieberegler verstellen einen Wert manuell eingeben oder auf die Felder mit den Pfeilen dr cken Die Kurven die den Korrekturbereich markieren werden in der Grafik verschoben Grafik gt Einstellungen Die grafische Darstellung kann vergr ert bzw verkleinert angezeigt werden Den Dialog f r die im folgenden beschriebenen Einstellungen rufen Sie auf indem Sie auf eine der beiden Achsen in der grafischen Darstellung klicken auto 1 Aktivieren Sie die automatische Anpassung der Darstellung indem Sie auf das K stchen klicken x aktiviert Werte f r x Achse und y Achse werden automatisch angepasst Zoom wird auf 100 gesetzt oO deaktiviert Geben Sie Werte f r die Darstellung ein Zoom 2 Geben Sie einen Wert zwischen 1 und 400 ein X Achse Y Achse 3 Geben Sie jeweils den unteren Min und den oberen Wert Max f r den Anzeigebereich ein Temperaturkorrektur Hilfslinien Dichtekorrektur Hilfslinien Aktivieren O Hinweis Sie k nnen entweder die Temperaturkorrektur oder die Dichtekorrektur aktivieren x aktiviert Das Ergebnis einer Messung wird bei schwankenden Messtemperaturen entsprechend korrigiert oO deaktiviert Es findet keine Temperaturkorrektur statt Inkrement 1 Geben Sie hier den Wert f r die Temperaturkorrektur ein I 2 Klicken Sie auf bernehmen um die Einstellungen zu bernehmen
255. nkung der Verwendung bestimmter gef hrlicher Stoffe in Elektro und Elektronikger ten Directive 2002 95 EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment sofern das Betriebsmittel gekennzeichnet ist mit provided that the equipment is marked with Sartorius AG G ttingen 2010 09 07 one Bes h iV SE Dr Reinhard Ba umfalk Dr Dieter Klausgrete Leitung Entwicklung Leitung International Certification Management Vice President R amp D Head of International Certification Management Mechatronik Mechatronics Mechatronik Mechatronics SAG 10RoHS008 LMA321PA 58 SOP 3 RD 045 fo3 Sartorius AG Weender Landstrasse 94 108 Goettingen Germany Phone 49 0 551 308 0 Fax 49 0 551 308 3289 www sartorius mechatronics com Copyright by Sartorius AG Goettingen Germany All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius AG The status of the information specifications and illustrations in this manual is indicated by the date given below Sartorius AG reserves the right to make changes to the technology fea tures specifications and design of the equipment without notice Status September 2010 Sartorius AG Goettingen Germany Public Nr WLM6009 a10081
256. nnect the PC to the device For a description of the procedure see page 20 HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Edit Values 1 Press a row to select it 2 Press the control to start editing EI The Device properties dialog appears Enter the IP address as well as further details on the network connection If working on the PC click Connect to connect the device and the PC via the IP network Press Apply to accept the values 6 Press Close The editing of the values is complete x S Delete You can delete a device from the list 1 Select Delete from the Edit menu The table is now displayed in delete mode i e the controls page 70 for selecting one or more rows are displayed at the bottom 2 Press a row The device is selected 3 Press Delete E The device is removed from the list 4 Press Close The deletion process is complete Copy You can copy the entry for a device Copied entries are inserted into the table again Copying an entry is an easy way to create similar entries Select Copy from the Edit menu The table is now displayed in copy mode i e the controls gt page 70 for selecting one or more rows are displayed at the bottom 1 Press a row The entry is selected 3 Press Close 2 Press Copy Selected rows are copied and inserted into the table as new values x The copy process is complete New 1 Select
257. nsity test Once you press Copy corresponding buttons become available See Controls in Measurement Calibration Details on page 70 1 Select an entry a block or all entries 2 To select several rows press Multi Now select several values using the Block 1 Block 2 control or select entries individually EE sartorius We cece mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 76 Press Copy Select a product from the Copy to dialog Specify whether the selected values are to be copied to the calibration of the product or the com pression test Press Close to return to the display Settings The Settings dialog appears It allows you to specify the appearance of the table of readings to look like See also Settings for tables Details on page 126 Print Selected measurement values can be printed out See page 53 for information on how to connect a printer From the menu select Measurement gt Table gt Print The table is now displayed in print mode i e controls page 70 for selecting one or more rows are displayed at the bottom Press a row to select it Note You can select one or more rows Press the Print control The selected table rows are printed Press Close The printing of the values is complete Export The table is exported to a csv file and stored on the connected USB stick Press Edit to change the file name Note If you are using the program o
258. nstalliert O Hinweis Wenn das Ger t w hrend des Start Vorgangs nicht mehr zu reagieren scheint dann entfernen Sie den USB Stick und schlie en ihn danach erneut an einen USB Anschluss an 9 2 Backup erstellen Wiederherstellen Backup erstellen Beim Erstellen eines Backups wird die gesamte Ger te Einstellung einschlie lich der Kalibrati onen und Messwerte auf den USB Stick bzw den PC gespeichert Dies sollte in regelm igen Abst nden gemacht werden um z B bei Problemen einen m glichst aktuellen Stand wiederherstellen zu k nnen Au erdem k nnen auf diese Weise alte Messwerte archiviert werden Die Funktion Backup ist nur verf gbar wenn Sie mit Zugriffsrechten der Stufe 4 oder h her angemeldet sind Falls sich das Messger t noch in einem anderen Zugriffszustand befindet m ssen Sie sich zun chst entsprechend neu anmelden 1 W hlen Sie den Men punkt Benutzerwechsel 2 Geben Sie im Dialog Anmeldung Ihren Nutzernamen und Ihr Passwort ein SHE sartorius 187 seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA Wartung und Pflege Durchsuchen AN 188 2 Klicken Sie auf bernehmen Die Funktionen im Bereich Service sind jetzt freigeschaltet und verf gbar Hinweis Nachdem Sie die gew nschten administrativen Arbeiten durchgef hrt haben sollten Sie sich wieder mit den Benutzerdaten f r den normalen Zugriff anmelden oder falls ein entsprechender Standardbenutzer angelegt ist die Bed
259. nts on the plotted curve using different symbols Select one or more entries Press Type Choose the type of the measuring point Table Edit Delete You can delete individual points on the plotted curve Select one or more entries Press Delete sartorius 119 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 120 The selected entries are deleted Table Edit Copy You can delete individual points on the plotted curve Select one or more entries Press Copy The selected entries are copied and added to the table Table Settings The Settings dialog appears You can modify the table of calibration results to suit your personal needs See Settings for tables Details on page 126 Table Print Selected measurement values can be printed out See page 53 for information on how to connect a printer Open the menu and choose gt Compression test gt Table gt Print The table is now displayed in print mode i e controls page 70 for selecting one or more rows are displayed at the bottom Press a row to select it Note You can select one or more rows Press the Print button The selected rows are printed out Press Close The printing of the values is complete Graph Test results are plotted as a graph Press the Compression test mode display or the symbol to switch to the table view Press the graphic to display the Compression test properties Deta
260. o Excel 2003 using the import function This TMV If the device is connected to a PC via an IP network and is operated using the PC an IP address must be assigned to the device in the network You define the network settings IP address etc for the device here The default IP address is 172 28 1 1 This IP address is set if the factory settings are restored Note Select Master from the drop down list Other settings only apply to the service department You only have to specify a gateway if your PC and the device are not in the same network If you have any questions ask your network administrator MW device If the device is connected directly to a PC you can use this function to reset the IP address of the device This is only necessary if you cannot change the IP address on the device itself and if the device needs to be integrated into an IP network with another address Once you have changed the IP address the device must be restarted in order for the change to take effect EE sartorius a eegg mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference MW device The settings in this area show the system configuration of your measuring device The system configuration may only be edited by Sartorius and can only be viewed by users with access rights of level 5 or higher Printer configuration O Note You need to be logged on with at least level 4 access rights to change these setting
261. o insert the entry into the table Example A value has been deleted by mistake and must be entered manually Values from another calibration are adopted to enable a comparison Table gt Settings The Settings dialog appears You can modify the table of calibration results to suit your personal needs See Settings for tables Details on page 126 Table gt Print Selected calibration values can be printed out See page 53 for information on how to connect a printer Select Measurement gt Calibration gt Table gt Print The table is now displayed in print mode i e controls page 70 for selecting one or more rows are displayed at the bottom Press a row to select it Note You can select one or more rows Press the Print button The selected rows are printed out Press Close The printing of the values is complete HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Table gt Export The table is exported to a csv file and stored on the connected USB stick EI 1 Press Edit to change the file name O Note If you are using the program on your PC the Export dialog appears Specify a storage location on the PC and change the name of the export file if necessary O Note Microsoft Excel 2003 The widespread and universal csv export format cannot be properly interpreted for Excel 2003 Rename the csv file as txt and import it into Excel 2003 using t
262. ob Sie einen einzelnen Eintrag Bemerkung Referenzfeuchte Typ oder alle Werte bearbeiten wollen Bemerkung Details auf Seite 227 Referenzfeuchte Details auf Seite 227 Typ Details auf Seite 227 Alle Werte Details auf Seite 228 Die Tabelle wird nun im Modus zur Bearbeitung angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen Seite 210 zum Markieren einer oder mehrerer Zeilen 1 Dr cken Sie auf eine Zeile um diese zu markieren 226 SEE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz Falls Sie die Eingabe eines einzelnen Wertes Referenzfeuchte Referenzdichte gew hlt haben erhalten Sie den entsprechenden Dialog zur Zahleneingabe Details auf Seite 268 bzw zur Texteingabe Details auf Seite 267 Falls Sie die Eingabe f r Typ gew hlt haben erhalten Sie den Dialog Typ gt Seite 227 Falls Sie die Eingabe f r alle Werte gew hlt haben erhalten Sie den Dialog Kalibrationseigen schaften 2 Seite 229 EI 2 Dr cken Sie auf die Schaltfl che zum Bearbeiten O Hinweis Zur Eingabe eines Referenzwertes des Typs oder einer Bemerkung k nnen Sie auch auf das entsprechende Feld im Tabelleneintrag dr cken Sie erhalten dann den Eingabedialog O Hinweis Entsprechend den Einstellungen f r Globale Einstellungen Details auf Seite 249 werden Werte gerundet angezeigt Bei der Eingabe geben Sie alle Dezimalstellen ein x 3 Dr cke
263. oder gestattet sind bleiben inaktiv Die Schaltfl che bernehmen kann erst gedr ckt werden wenn eine Zahl angegeben ist Die Eingabe des Dezimalpunktes ist nur m glich wenn f r die Eingabe Dezimalwerte erlaubt sind Die Eingabe des Minuszeichens ist nur m glich wenn f r die Eingabe negative Werte erlaubt sind Entf l scht die Ziffer vor dem Cursor Der Cursor kann auf dem Touchscreen mit dem Finger verschoben werden EE gibt an dass die Eingabe in Exponentialschreibweise wissenschaftliche Notation erfolgt EE sartorius e H mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz S80 Dabei wird eine bereits erfolgte Eingabe nicht umgerechnet Sie erkennen diese Eingabeform da ran dass der Buchstabe E angezeigt wird Bei Arbeit mit einer Tastatur k nnen Ziffern Dezimalpunkt etc auch Uber die Tastatur eingege ben werden Hinweis Zur Abtrennung von Dezimalstellen wird in allen Sprachversionen ein Dezimal Punkt geschrieben Hinweis Entsprechend den Einstellungen f r Globale Einstellungen Details auf Seite 249 werden Werte gerundet angezeigt Bei der Eingabe geben Sie alle Dezimalstellen ein Einstellungen f r Tabellen Die Darstellung von Tabellen kann hier individuell angepasst werden Spalten x Spalte wird angezeigt CL Spalte ist ausgeblendet Dr cken Sie auf den entsprechenden Eintrag um eine Spalte ein bzw auszublenden berschriften Hier bestimmen Sie we
264. og Printer Configuration zu schlie en Einrichten eines direkt angeschlossenen USB Druckers Hinweis Nur bei Labormessger ten vom Typ LMA321PA und LMA316PA k nnen USB Drucker direkt angeschlossen werden Voraussetzungen Sie sind mit Zugriffsrechten der Stufe 4 oder 5 angemeldet Der Drucker ist am LMA321PA LMA316PA angeschlossen siehe Seite 155 und eingeschaltet W hlen Sie den Men befehl Systemeinstellungen gt Konfiguration gt Druckerkonfig Sie er halten den Dialog Printer Configuration Hinweis Das Plugin Printer Configuration steht nur in englischer Sprache zur Verf gung Zum Hinzuf gen eines Druckers dr cken Sie auf Add New Printer Hinweis Bei der Eingabe des Druckernamens d rfen keine Leerzeichen und nicht die Zeichen und verwendet werden Geben Sie ber die virtuelle Tastatur einen Namen f r den Drucker ein unter dem dieser Drucker in TMV ausw hlbar sein soll und dr cken Sie auf bernehmen Der Dialog wechselt automatisch zum Register Printer Device ERE sartorius a o mechatronics WLM6009 a10081 LMA316PA LMA321PA Weitere Funktionen 10 Printer Configuration Administration Printer Device Make Model Driver Printer Options Printer Version 0 1 4 HP_LaserJet Deg Se ostname CA d Init Device Port Queue Device URI usb HP LaserJet 201020 Set New Device URI Device Info usb HP LaserJet 201020 zs Help EJ
265. olumn header and dragging it to another position Profiles The settings for displaying the table are saved as the default profile You can save your own settings in one of three other profiles Press the list box Select a profile Press Save to save the settings in the selected profile You cannot overwrite the default profile Press Restore to restore the settings from one of the profiles Press Apply The table is displayed in accordance with the settings Note You can change the width of a column by pressing the line separating two column headers and pulling it to the left or right HE sartorius coe mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 13 12 Messages Status line messages Details on page 127 Error messages Details on page 128 Status line messages Below is a list of the messages that are output by the device into the status line Status line Details on page 67 Status line display Action Sensor empty The device is ready for measurement and is waiting to be filled Measurement in progress The device is attempting to take a measurement If no meas ured value is displayed wait for further information Sensor empty Carry out empty sensor adjust gt page 70 Sensor half full only for bypass measurement The sensor seems empty Check the following device settings Level sensor setting Macro programming Device version MW value Carry
266. on i e the number of installed circuit boards see Technical data from page 63 2 sartorius 109 seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Library All installed circuit boards are displayed Up to 4 circuit boards can be configured With regard to the configuration note that only wired outputs ports can be used The analog outputs then each deliver 0 mA or 4 mA and 20 mA for the set percentage values and values in mA when the device is started up and for interruptions in measuring The start value must not be 0 since this would cause a warning signal to be generated when the device is started up The circuit boards and ports that you use and the signals that can be evaluated depend on the configuration of your system Configuration This menu has the following sub items Sensor modes Details on page 110 Communication Details on page 112 MW device Details on page 115 Printer configuration Details on page 115 User configuration Details on page 115 Sensor modes The table lists all available sensor modes You need to be logged on with at least level 4 access rights to change these settings Sensor modes defined by the manufacturer are indicated by a green tick User defined modes are not marked This menu has the following sub items Edit Details on page 110 Settings Details on page 112 Print Details on page 112 Export Details on page 112
267. on editing process Values in the Value column can only be edited if the macro in question is activated Yes in the Available column Macros that are absolutely necessary in order for the system to function cannot be deactivated The entry Yes in the Available column is greyed out in such cases 117 mechatronics WLM6009 a10081 Macro name LMA316PA LMA321PA Operator Interface Reference Explanation Auto ES adjust The empty sensor adjust is carried out automatically for process measuring devices if the sensor is empty The interval to be used for carrying out empty sensor adjusts can be defined in Measurement interval Data over modbus TCP Data over ser link Data over server IP address Specifications on the sending of measurement data via the serial interface or Ethernet TCP IP Density value on PMD320PA In the case of the PMD320PA you can define here whether you want the density to be displayed on the screen too Max age of ES adjust day After each save cycle the system checks the age of the last empty sensor adjust measurement and issues a warning i e warning indicators light up if the specified value in days has been exceeded Max freq dev of ES adjust MHz Defines the required precision stability of the empty meas urement If this stability is not achieved the measurement is terminated with an empty sensor check error In gen eral 0 01 MHz is an optimum val
268. ord will be deleted You can neither delete the default user nor the last level 5 user Sensor modes A sensor mode is assigned to each product The modes supported by a sensor are normally detected automatically by devices that are connected to the evaluation unit by a data cable When you create a product you therefore only need to select a mode from the list If multiple sensor modes exist the optimal sensor mode must always initially be determined using a compression test see page 32 It is best if the compression lines representing different moisture values intersect in one point ideally the zero point and if a sufficient number of measuring signals approx 3 20 MHz of frequency offset is available EE sartorius a o mechatronics WLM6009 a10081 LMA316PA LMA321PA Other functions CH EI B Library DF to In so called multiplex units with 2 sensors attached the system loads the modes supported by both sensors i e the number of available modes increases Note Imported sensor modes can neither be edited nor deleted In case the sensor modes were not automatically loaded when the system booted you can also choose System settings gt Configuration gt Sensor modes gt Read from the menu and load the modes later Editing Sensor modes Prerequisites You are logged on and own level 4 or 5 access rights There are basically two cases in which it is necessary to edit the sensor modes
269. ory settings for the existing products to free memory cells for the new product Measurement gt Mean You use this entry to specify the number of results needed to calculate the mean value of each measuring cycle Note The entries in MW type and in the AB area provide information only and cannot be edited Press Apply The product has now been created The moisture and density calibration for the product can now be carried out Note The settings for a product can be changed copied or printed out A product can be deleted again For information on these points see the reference guide section which starts on page 103 Compression test This test must be carried out prior to each calibration of a product which to a lesser or greater extent can be compressed In the case of products with constant densities e g plate elements this test is not absolutely necessary but is recommended It allows you to form an idea of the raw values for frequency and width change in order to recognize and eliminate borderline measure ments straight away Products that can be compressed are loosely packed into the sensor and then increasingly compressed by shaking or pounding Each compression state is saved separately The regres sion line which results from the different density points at uniform moisture ideally intersects the AB diagram at its origin If not the resulting AB offset must be taken into account for the subse quent calibration If
270. ouchscreen N f Laboratory Moisture Analyzer LMA321PA USB Anschluss LMA321PA Tragegriff Betriebsanzeige LMA316PA Monitor und Maus sind nicht Bestandteil des Lieferumfangs 00000000 Gap zartorius USB Anschluss Betriebsanzeige SES Tastatur Tragegriff 148 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Produktbeschreibung 3 2 Ger teansicht Anschl sse auf der R ckseite Ein Ausschalter Sicherungen MW Gen 2 MW Det 1 MW Det 2 MW Gen 1 Temperatur sensor ext m Sensor2 Sensor1 m Ethernet Anschluss 110 230 V AC Ger tef e Service Schnittstelle Monitor USB 2 Anschl sse Tastatur Maus COM 1 O Hinweis Mit gekennzeichnete Anschl sse Verbindungen sind optional und nicht bei allen Geraten vorhanden HE sartorius mechatronics 149 WLM6009 a10081 LMA316PA LMA321PA Produktbeschreibung oooo Kurzbeschreibung der Anschl sse MW Gen MW Det Anschluss der Mikrowellenkabel zu den entsprechenden Sensor Anschl ssen ber diese Verbindung werden die Mes
271. out calibration Switch to Measurement mode Out of range No non linear calibration can be carried out for the microwave value as there is no valid value in this range SHE sartorius 127 cece x mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 128 Error messages Error messages are output in the status line or the display An error code is indicated by a preceding E in the display panel and by the abbreviation of the error block MV MWT RE or MT in the status line The six digit error messages are made up of three blocks of 1 or 2 digits each Block 1 provides general information on the type of the error Error code 2 indicates an MT error the exact type of the error is specified in block 3 Error code 4 indicates an RE error the exact type of the error is specified in block 2 Block 2 indicates that measurements are possible but outside the approved range If block 3 displays an error code no measurements are possible for technical reasons e g be cause the sensor is not connected up using a cable Check the cable connections and contact the service team if necessary Block 1 MV or MWT measured value General information on error type Block 2 RE range error Measurement outside permitted range Block 3 MT measurement task Measurement not possible HE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Th
272. ove the USB stick and then insert it into a USB port again 10 2 Creating a backup restoring the system Creating a backup When you create a backup all of the device settings including the calibrations and measured values are stored on the connected USB stick or PC You should do this regularly since it means that you can restore a recent state if problems occur It also allows the archiving of old measured values The Backup function can only be used by users with level 4 access rights or higher If the meas uring device is currently being used with a login assigned to another level you must log in again with an appropriate user as follows 1 Select the Change user menu item 2 When the Login dialog appears enter your user name and password Click Apply This releases the functions in the Service menu O Note After carrying out administrative work you should either change your login to your normal access rights or if a default user is defined restart the control software to prevent unauthorized modifications of the system settings or calibrations Your next steps differ depending on whether you are working directly on the measuring device with a USB stick or are controlling the device using an external PC EE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Service and maintenance Browse AA AN Browse 60 2 Backup on USB stick Insert the provided USB stick into the
273. panel Measuring results are displayed on the display panel However other control elements or tables are also displayed here for administrative tasks A description can be found under the corre sponding menu items General information Cursor position and selected items A cursor appears on the display panel regardless of the type of display It appears at the position defined by the user The values of the measurement at the cursor position can be displayed simultaneously to the values of the current measurement in the analog display for example The cursor position is indicated in red on the display panel red border in the table red line in the graph EE sartorius a o mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference The cursor position does not necessarily show the current and most recent measurement Unlike the cursor position selected entries have a dark background 1 2007 04 13 14 37 54 REMARK 1 7 28 9 06 2 2007 04 13 14 37 55 REMARK2 E 9 10 AAAS 2007 04 13 6 2007 04 13 14 38 01 REMARK6 7 21 Salt 7 2007 04 13 14 38 02 REMARK 7 7 29 5 07 8 2007 04 13 14 38 04 REMARK8 7 28 9 08 9 2007 04 13 14 38 05 REMARK 9 7 27 9 14 10 2007 04 13 14 38 06 REMARK 10 TEN 5 08 Table graph reading Measurement mode The display screen shows the results of the measurement You select the type of display in the Measurement menu
274. pecify whether the curve is to have an extrem um here Select the Extremum option if you know that one of the values represents a top or bot tom value a Curve with extremum U Curve without extremum A Correction 2 Specify whether and how a correction is to be carried out for the calibration curve here The cal ibration process then takes variations concerning the temperature and or density of the samples into account in the manner specified The system issues a corresponding message if there are insufficient measured values to enable a sensible correction EE sartorius cece 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 92 Note Temperature and density variations can only be taken into account if corresponding values are available for the samples As a rule the temperature should be taken into account in the case of temperature variations of more than 5 C Press Apply to accept the setting and calculate the calibration Once the calibration has been successfully calculated the parameters are displayed in the 1st 2nd display panel See 1st display 2nd display Press Expert to make all settings manually Press auto to calculate the calibration automatically Expert You can specify the calibration settings manually here Settings made beforehand linear non linear number of segments are applied but can be changed here You can set the limits of the individual s
275. ph ig 19 2007 04 13 141416 REMARK 19 7 28 517 2641 reading 20 20 2007 0413 141418 REMARK20 727 517 26 4 21 21 2007 0413 14 14 20 REMARK2I 7 517 26 4 22 22 2007 0413 141422 REMARK22 722 5 08 26 4 23 23 2007 0413 141425 REMARK 23 7 30 5 12 26 3 Measuring amp calibration x i Al Re M controls Stop Probe ES adjust irst Pageback Step back Goto Step forward Page Forward Goto last Navigation buttons Explanations about the following dialogs can be found at the end of this chapter Jump Details on page 124 Text input Details on page 124 Numerical input Details on page 125 Settings for tables Details on page 126 There is also a list of messages Messages Details on page 127 Information on devices without a touchscreen and on controlling a device from an external PC If the device has no touchscreen and or is controlled using a PC please note the following Use the mouse to click on the controls Instead of the virtual keyboard an input field appears if you need to make an entry Enter the re quired numbers or characters using the keyboard connected to the measuring device or PC 13 1 Menu Press this control to open the menu The menu provides access to all commands and setting A options 12 HE sartorius a H 0 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 13 2 66 Note You may not be able to access all of th
276. phical 245 100 depiction gt 1 leg eae an EE sartorius cece x mechatronics WLM6009 a10081 LMA316PA LMA321PA Calibration The results of the calibration settings are shown on the right hand side of the dialog Press the List control to display all of the parameters in a list Press Display in the dialog for making expert settings The graph is shown again You can now save the calibration or return to the dialog for making expert settings Press Auto The Calibrations tab shows a list of all calibrations which are feasible with these parameters O Note If you are using the programme on your PC click Apply On a PC you can move the individual programme windows to position the graph and input dialog next to each other Printing a calibration If a printer is connected via a USB port or network connection you can print the graphical depic tion or calibration table if required Printing a graph 1 Press Calibration gt Moisture Density calibration gt Graphics gt Print The standard print dialog appears you can specify the print settings and trigger printing by clicking Print Printing a table 1 Press Calibration gt Moisture Density calibration gt Table gt Print 2 Select the parts of the table you wish to print To print the entire table press All 3 Press Print The standard print dialog appears you can specify the print settings and trigge
277. product names Noms Jess we T TEWS 100 50 self 1 Coffee AD 7 2 Coffee AD 8 3 Cigarettes CY 41 41 REFERENCE Linked calibration d 44 gt 28 Apply Cancel Goto first Page back Step back Goto Step forward Page Forward Goto last Products have already been created in the system This means that the corresponding calibration for each product has already been carried out The data for the sensor used for the measurement process constitutes part of the product settings You use the Product settings Details on page 103 menu item to create new products HE sartorius 13 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference O O 2 nom 4 5 O 74 Note The currently selected product is indicated by a green tick in the No column Press the column header to sort the table The current sort order is indicated by an arrow in the column header Press the row containing the name of the product to be measured Note Products with similar properties can reference the same calibration If a product references the calibration of a similar product corresponding information can be found in the Reference to calibration line In the case of products with their own calibration the Cal link column contains the entry self Note Press the navigation controls see Navigation Details on page 72 to view products you cannot see immediately Press Apply
278. r Then repeat steps 8 to 10 Press Save The dialog for entering a remark is shown You can enter the number of the sample here for example Then press Apply EE sartorius a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Calibration VG 14 15 16 17 18 19 g 21 The dialog for entering reference values now appears How you proceed hereafter depends on whether you used samples with existing reference values or whether the samples are now being sent to your laboratory for the determination of the reference values Option 1 Reference values exist Enter the reference value for the sample and press the Apply button green tick The measured value is displayed in the table Note Even if several measurements are taken for a sample only one line with the average value of the measurements is shown Option 2 Reference values do not yet exist Leave the input field in the Reference moisture or Reference density dialog empty and press Cancel The measured value is displayed in the table without reference values Send the samples for which you have measured calibration values to the laboratory for the deter mination of the reference moisture or density Note The accuracy of the calibration and thus of all later measurements depends on the accuracy of the reference values The moisture level of the samples must not change during transport and measurement in the laboratory Observe the info
279. r Kurve sind entsprechend mehr Kalibrationsmessungen notwendig O Hinweis Wir empfehlen Werte zun chst aus der Kalibration herauszunehmen und erst nach dem Erstellen einer zufriedenstellenden Kalibrationskurve die tats chlich berfl ssigen Werte zu l schen Werte aus der Kalibration herausnehmen W hlen Sie im Men Kalibration gt Feuchte Dichte Kalibration gt Tabelle gt Bearbeiten gt Werte gt Typ Die Tabelle wird nun im Modus zum Bearbeiten angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen Seite 210 zum Markieren einer oder mehrerer Zeilen 1 Dr cken Sie auf die Zeile mit dem ungeeigneten Wert Der Wert ist markiert 2 Dr cken Sie auf Typ EZ Sie erhalten den Dialog Typ 3 Deaktivieren Sie die Einstellung g ltig und dr cken Sie bernehmen In der Tabellenspalte Typ wird der Wert nun eingeklammert dargestellt und nicht mehr f r die Berechnung verwendet x 4 Dr cken Sie auf Schlie en Der Bearbeitungs Modus ist beendet SHE sartorius 175 cece mechatronics WLM6009 a10081 LMA316PA LMA321PA Kalibrieren Werte loschen Wahlen Sie im Ment Kalibration gt Feuchte Dichte Kalibration gt Tabelle gt Bearbeiten gt L schen Die Tabelle wird nun im Modus zum L schen angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen Seite 210 zum Markieren einer oder mehrerer Zeilen 1 Dr cken Sie auf die Zeile mit dem fehlerhaften Wert Der Wert ist markiert O
280. r externen PC berblick Installation der Software TMV Messger t und PC verbinden Kalibrieren Was Sie beim Kalibrieren beachten m ssen Anmelden zum Kalibrieren bzw Anlegen von Produkten Produkt anlegen Verdichtungs Test Kalibrieren Messen Messung im Labor Messwerte drucken 2 sartorius mechatronics 141 141 141 141 142 142 143 143 143 143 144 144 144 147 148 149 152 153 153 154 156 156 157 157 159 159 159 163 165 165 166 167 169 172 181 182 183 8 9 9 1 9 2 9 3 9 4 9 5 9 6 10 11 12 12 1 12 2 12 3 12 4 13 13 1 13 2 13 3 13 4 13 5 13 6 13 7 13 8 13 9 LMA316PA LMA321PA Inhaltsverzeichnis Kurzanleitung Messen Wartung und Pflege Software Update Backup erstellen Wiederherstellen Sicherungen auswechseln Reinigung Transport und Lagerung Entsorgung Technische Daten Abhilfe bei Problemen Weitere Funktionen Benutzer mit unterschiedlichen Zugriffsrechten einrichten Sensormodi Drucker einrichten Referenzstandard Bedienoberfl che Referenz Men Anzeige Schaltfl chen Messung Kalibration Produkteinstellungen Systemeinstellungen Service Benutzerwechsel 13 10 Sprache 13 11 Weitere Dialoge 13 12 Meldungen 14 15 Schnellzugriffe Shortcuts Glossar 185 187 187 187 190 191 191 191 192 193 195 195 196 198 203 205 205 206 210 213 225
281. r has been entered You can only enter a decimal point if values with decimal places are permitted e You can only enter a minus sign if negative values are permitted J Del deletes the number before the cursor You can move the cursor by pressing the screen with your finger EE indicates exponential input scientific notation This means that an entry which has already been made is not converted This form of entry is indicated by the letter E If you are working with a keyboard you can also enter numbers decimal points and so on using the keyboard in question O Note A point full stop is used as the decimal separator in all language versions SHE sartorius 125 seg 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference O 126 Note Values are displayed rounded off in accordance with the settings in Global settings Details on page 108 When making entries enter all decimal places Settings for tables You can customize the depiction of tables here Columns x _ The column is displayed g The column is hidden Press the relevant entry to show or hide a column Headers Here you determine the action to be carried out when a column header is pressed Sortable Table columns can be sorted You change the sort order by pressing on the relevant column header The current sort order is indicated by the arrow displayed in the header Movable You can move a column by pressing the c
282. r printing by clicking Print EE sartorius cece 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Calibration SS HE sartorius mechatronics WLM6009 a10081 7 Quick guide to measuring Caution AN page 7 and following and added to some of the working steps LMA316PA LMA321PA If you decide to keep this Quick Guide separate from the manual you must make sure that eve rybody working with it knows and takes heed of the safety instructions contained in the manual O Note This Quick Guide describes a standard measuring process using the laboratory unit with a touch screen Refer to the manual and the online help to find descriptions of other models and detailed information Some of the functions described depend on your access rights and may therefore not be available to you Overview of the unit and its user interface display Back On Off switch lox fe User interface Front Display touch screen Power on ready indicator Menu Status line Help DE a Moisture 7 30 Density 5 12 mg cm Ee 8 lt SR elle Selected Measurement Er pes _ ren m 7 30 Di D J te product Coffee 0001 7 00 Moisture 10 00 3 00 Density 6 00 No Date Time Remark Moisture Density Temp 14 14 2007 04 18 14 14 04 REMARK 14 731 5 14 26 3 15 15 2007 04 13
283. ramme und deaktivieren Sie ggf alle Virenschutzprogramme f r die Zeitdauer der Installation Legen Sie die TMV CD in das CD oder DVD Laufwerk Ihres PCs Starten Sie das Installationsprogramm durch Doppelklicken auf die Datei TMV_ lt Versionsnum mer gt _Setup exe auf der CD z B mithilfe des Windows Explorers SHE sartorius 159 mechatronics WLM6009 a10081 LMA316PA LMA321PA Steuerung ber externen PC 160 TWN Installation m Wm gt Willkommen im TMY Setup Assistenten A 3 Vor dem Start der Installation von TMY w hlen Sie eine Sprache aus H klicken Sie auf Weiter um fortzufahren E Weiter gt Abbrechen 3 W hlen Sie im Startdialog des Installationsprogramms die gew nschte Sprache des Installati onsprogramms aus dem Listenfeld und klicken Sie auf Weiter Hinweis Die Sprache des Startdialogs richtet sich nach der Sprache Ihres Betriebssystems In der Sprache die Sie im Startdialog ausw hlen erscheinen dann alle weiteren Dialoge des Instal lationsprogramms TMV startet dann ebenfalls in dieser Sprachversion Sie k nnen die Software aber jederzeit auf eine der anderen verf gbaren Sprachversionen umstellen Klicken Sie im Begr ungsdialog ebenfalls auf Weiter Im n chsten Dialog w hlen Sie das Verzeichnis aus in dem die Software auf Ihrem PC installiert werden soll OTW Installation ck TMY wird in das unten angegel erzeichnis installiert
284. rature sec 118 Maximum time that the system waits to see if the stability criteria defined in Global settings Temperature are met for the temperature measurement page 109 HE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 13 8 Service MW test MTask test Note These settings must only be changed by service engineers Help for this topic is not yet available Compression test Note You need level 5 access rights to change these settings See the Compression test section of the manual Product choice You call up the product choice dialog using the menu or by pressing the product names You use the Product settings Details on page 103 menu item to create new products Note The currently selected product is indicated by a green tick in the No column Press the column header to sort the table The current sort order is indicated by an arrow in the column header Press the row containing the name of the product to be tested Note Press the navigation controls see Navigation Details on page 72 to view products you cannot see immediately Press Apply You can now start or edit a compression test for the selected product Table The results measured in the test are displayed in a table Press the Compression test mode display or the graphic symbol to switch to the graphical display Table Edit Type You can depict individual poi
285. rd als gedr ckt mit der Benennung Block 2 dargestellt Markieren Sie durch Dr cken eine andere Zeile Dr cken Sie diese Schaltfl che um das Ende des Blocks zu bestimmen Die markierten Eintr ge k nnen jetzt bearbeitet werden Alle Markiert alle Eintr ge Wiederholtes Dr cken hebt alle Markierungen auf Schlie en Beendet die zur Zeit gew hlte Art der Bearbeitung x Mm Die Anzeige bleibt bestehen bis Sie eine andere Anzeige Messung Kalibration w hlen SHE sartorius 211 seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz Nr A CO J D 212 Navigation Diese Schaltfl chen helfen Ihnen bei der Navigation Sie stehen bei Ansicht als Tabelle und bei der grafische Darstellung zur Verf gung Mit diesen Schaltfl chen setzen Sie den Cursor an eine andere Position Die Anzeige wird an die neue Cursorposition angepasst Springt zum ersten Eintrag in einer Tabelle I lt Der erste Eintrag kann in Abhangigkeit von der momentanen Sortierung der Tabelle unterschiedlich sein Springt zum ersten Wert der grafischen Darstellung Die Anzeige der Tabelle wird um eine Seite 10 Eintr ge zur ck geblattert Der Cursor steht in der obersten sichtbaren Zeile Die Anzeige der Tabelle wird um einen Eintrag zur ck gebl ttert Erlaubt den Sprung zu einem beliebigen Eintrag in der Tabelle Lesen Sie dazu den Abschnitt Sprung Details auf Seite 267 Die Anzeige
286. re colour and granularity of the product surface It is important that the product crosses the measuring field evenly HE sartorius seg x mechatronics WLM6009 a10081 A ACCESS e UC 49 Alan zus e seen tan 82 B Back VIEW EN rasen dla an 73 B r En GE 77 C GalL NK u a ea 31 Calibration 2 2 2 2 2 35 84 Delete values 38 Density 2 2 4 ada as en 94 Exclude values 38 EXpelt rasanten 92 101 Expert mode 40 Moisture 2222222222222 85 Offset vun Sean eee oes che eee re Ses 39 Product choice 84 Samples 29 RRE 40 91 100 Calibration type Linga 262556 Ooi Sees eee te ee 91 100 Non linear 222222 91 100 Compression test ccecceceeeeeeeeeeeeeteneees 32 Configuration eee eeeeteeeeeeeeeeeeeeteeeeeeeeeeeeaaees 110 Printer setup 53 Sensor modes 2055 50 user access definition 49 Connection SEHR 22422 Hear are 14 Ethernet 2 a re 14 Keyboard 14 24 Monitor oss Ge Meee a ee a 14 MOUSE a2 6 505 Ser re Das se 14 MW Det 14 24 MW Gen 14 24 Peo menena ende ee 20 SENSOR T 2 ah arte eaten 4s Geena act ae 14 Service interface 0 0 0 0 c eee 14 Temperature sensor 24 WS Ba ce ee een ee De See eee 15 Create SCORE ween ee ete Gat en oe 50 116 Create StatistiC deiere Kasten 77 TTC 66 Change position 72 Determine cursor position 77 Position 2 2 3 42 42 2 ehren 74 D REI 1
287. re Listenfeld W hlen Sie den Befehl Fabrikeinstel lungen wiederherstellen Dr cken Sie auf bernehmen Reset Das Programm wird beendet die Bedienoberfl che wird neu gestartet Schlie en Wenn Sie das Programm am PC nutzen w hlen Sie Service gt Schlie en um das Programm zu beenden Benutzerwechsel Geben Sie im Dialog Anmeldung den Ihnen zugeteilten Benutzernamen und das dazugeh ren de Passwort ein Dr cken Sie auf ein Eingabefeld Sie erhalten den Dialog zur Texteingabe Details auf Seite 267 Dr cken Sie auf bernehmen Damit melden Sie sich an Entsprechend den ihnen zugestandenen Berechtigungen sind einige Men punkte nicht sichtbar oder inaktiv grau Sprache In diesem Men w hlen Sie die Sprache in der die Anzeige erfolgen soll Dr cken Sie auf den Men eintrag mit der gew nschten Sprache Die Umstellung erfolgt sofort Weitere Dialoge Diese Dialoge werden in verschiedenen Zusammenh ngen angezeigt Sprung Details auf Seite 267 Texteingabe Details auf Seite 267 Zahleneingabe Details auf Seite 268 Einstellungen f r Tabellen Details auf Seite 269 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz Sprung Pos ED EC 429 Abbruch wa bernehmen 1 W hlen Sie ob die Anzeige zu einer Position oder zum Wert eines bestimmten Zeitpunktes sprin gen soll Dazu dr cken Sie auf das Listenfeld
288. reinstellungen wie Papierformat oder Druck aufl sung vorgenommen Die angezeigten Einstellm glichkeiten sind abh ngig vom Druckermo dell Sind mehr Einstellm glichkeiten vorhanden als dargestellt werden k nnen k nnen Sie ber die Tasten Up und Down zwischen den verschiedenen Anzeigen wechseln Durch Dr cken auf Set Printer Options werden die ge nderten Voreinstellungen des Druckers bernommen Ge nderte Einstellungen die noch nicht bernommen wurden werden rot dargestellt SHE sartorius 257 seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz U k 258 Benutzerkonfiguration Hinweis F r diese Einstellungen m ssen Sie mit Zugriffsrechten mindestens der Stufe 5 angemeldet sein Sie sehen die Tabelle der angelegten Benutzer Die Tabelle kann sortiert werden Ein Benutzer kann als Standardbenutzer festgelegt werden Ist ein Standardbenutzer definiert so startet das Ger t automatisch nach dem Anschalten mit den Rechten dieses Benutzers ohne Passwort Abfrage unabh ngig davon welcher Benutzer vor dem letzten Ausschalten ange meldet war Wenn kein Standardbenutzer definiert ist werden Sie immer direkt nach dem Starten der Software aufgefordert sich anzumelden Der Standardbenutzer ist durch ein X gekennzeichnet Wenn Sie einen anderen Benutzer als Standardbenutzer festlegen wollen m ssen Sie vorher dem Standardbenutzer diese Eigen schaft entsprechend aberkennen Dr c
289. rgestellter Zeitraum Spanne Tage Pause Das Ger t kann eine Unterbrechung der laufenden Messung als Pause erkennen Die Kurve in der grafischen Darstellung wird bei erkannten Pausen unterbrochen Geben Sie hier die Zeitspanne ein die zwischen zwei Messungen liegen muss damit eine Pause erkannt wird bei Auswahl Pos Spanne ist Anzahl der Positionen Messwerte die dargestellt wird Der kleinste m gliche Wert ist 2 Y Achse In der Grafik k nnen wahlweise eine oder zwei Messkurven dargestellt werden Hier bestimmen Sie welche Messwerte angezeigt werden mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz 220 Wert Drucken Sie auf eines der beiden Listenfelder um die Messwerte auszuwahlen die angezeigt werden Wahlen Sie zwischen Feuchte Dichte Temp Temperatur Aus keine Anzeige nur im zweiten Feld m glich auto Dr cken Sie auf das K stchen um die Skalierung der Y Achse automatisch anzupassen Dabei wird der gesamte Messverlauf gezeigt Die Skalierung kann f r zwei Kurven unterschiedlich gew hlt werden Die Werte der ersten Kurve werden in der entsprechenden Farbe links die der zweiten Kurve rechts dargestellt Wenn auto deaktiviert ist w hlen Sie in den Eingabefeldern Werte f r die gew nschte Darstel lung Min Max Geben Sie hier den kleinsten und den gr ten Wert an der dargestellt werden soll Dr cken Sie auf ein Eingabefeld und Sie erhalten
290. rhalten den entsprechenden Dialog zur Zahleneingabe Details auf Seite 268 bzw zur Texteingabe Details auf Seite 267 Geben Sie den Wert ein Dr cken Sie auf die bernehmen Schaltfl che gr nes H kchen HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Kalibrieren Kalibrationskurve korrigieren 1 Wahlen Sie im Ment Kalibration gt Feuchte Dichte Kalibration gt Grafik Angezeigt werden die errechnete Kalibrationskurve die Referenzwerte und die Abweichung der einzelnen Werte MW Feuchte 0 31 0 30 0 29 0 28 0 27 0 26 0 25 0 24 0 23 0 22 6 23 6 24 6 25 6 26 6 27 6 28 6 29 6 30 Referenzfeuchte Die Kurve verbindet die Mittelwerte der Referenzwerte In der Grafik erkennen Sie gegenenfalls einzelne Werte die sehr von diesem Mittel abweichen und daher die Kurve verf lschen Solche Ausrei er sind h ufig das Ergebnis fehlerhafter Referenzwerte oder fehlerhafter Eingabe Einzelne Werte k nnen aus der Kalibration gel scht werden Alternativ dazu k nnen einzelne Punkte aus der Kalibration herausgenommen werden Die Werte sind dann zwar noch vor handen bleiben aber bei der Berechnung unber cksichtigt Es besteht die M glichkeit anstatt der linearen Kurve eine nichtlineare Kurve zu w hlen die gegebenenfalls in bis zu 4 Segmente unterteilt ist Dadurch ist es m glich die Kalibrationskurve dem produktspezifischen Verhalten genauer anzupassen Je nach Komplexit t de
291. ringe Dichte kleine Frequenz Hohe Feuchte hohe Frequenz Hohe Dichte hohe Frequenz Feuchte Dichte Feuchte Offset Dichte Offset Ein Offset wird angegeben wenn auf die Kalibration eines hnlichen Produktes verwiesen wird oder wenn zwischen angezeigtem Wert und tats chlichem Wert Labor konstant die gleiche Diffe renz festgestellt wird O Beispiel Sie geben als Offset 1 ein Wenn mit der Ursprungskalibration als Messwert hier 10 angezeigt werden wird mit der referenzierenden Kalkulation 11 angezeigt Obere Untere Grenze Hiermit legen Sie die Grenzen fest bei deren berschreitung durch Messwerte ein Alarm aus gel st wird Falls das entsprechende K stchen nicht aktiviert ist wird f r Messungen in dem jeweiligen Bereich kein Alarm ausgel st MW Typ Diese Angaben dienen zur Information bei R ckfragen und k nnen nicht bearbeitet werden Messung gt Mittel Hier legen Sie fest wieviele Messungen bei diesem Produkt zum Ermitteln des Mittelwerts jedesmal durchgef hrt werden m ssen Speicher Wahlen Sie hier die Anzahl der Speicherplatze die fur Messwerte fur das Produkt reserviert werden sollen Die hier eingegebene Zahl entspricht ungefahr den Zeilen in der Tabelle der Messwerte Wahlen Sie auto wenn ein Produkt den fur Messwerte verfugbaren Speicher komplett nutzen darf Falls Sie mehrere Produkte anlegen teilen Sie die Anzahl der Verf gung stehenden Speicher pl tze ca 2000 entsprech
292. rius er cece x mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 13 5 84 Calibration A calibration must be carried out once for every product Every calibration begins with the selection of a product See Product choice Details on page 84 Choose whether to carry out a moisture or density calibration See Moisture calibration Details on page 85 or Density calibration Details on page 94 Please note that the procedure for calibration in the laboratory is different to the procedure for the in process calibration A single calibration is assigned to every product This calibration can be enhanced and refined over time The calibration table with all entered values is saved automatically Product choice You call up the product choice dialog using the menu or by pressing the product names Name Remark MC CC Cal link 1 Coffee AD 7 TEWS 100 self 2 Coffee AD 8 TEWS 3 Cigarettes CY 41 41 REFERENCE Linked calibration d x jaa A gt gt SI E Ae Goto first Pageback Step back Goto Step forward Page forward Goto last To create new products choose Product settings Details on page 103 Note The currently selected product is indicated by a green tick in the No column Note The REFERENCE product is only required for the optional reference standard function Press the column header to sort the table The current sort order is indica
293. rmation on calibration from page 29 As soon as you obtain the reference values for the measured samples you enter them into the calibration table as follows In the menu select Calibration gt Moisture Calibration or Density calibration gt Table gt Edit gt Values In the submenu select either Reference moisture or Reference density Note Alternatively you can choose All values When you press the Edit control see below the Calibration properties dialog appears and you can edit all values for this calibration The table is now displayed in edit mode Press the relevant row to select it Press the control to start editing The Numerical input Details on page 125 or Text input Details on page 124 dialog appears Enter a value Press the Apply control green tick sartorius si mechatronics WLM6009 a10081 LMA316PA LMA321PA Calibration 38 Correcting the calibration curve In the menu select Calibration gt Moisture Density calibration gt Graphics The calibration curve reference values and deviation of the individual values are displayed MW moisture 0 31 0 30 0 29 0 28 0 27 0 26 0 25 0 24 0 23 0 22 6 23 6 24 6 25 6 26 6 27 6 28 6 29 6 30 Reference moisture The curve connects the average values of the reference values In the graph you may detect indi vidual values that deviate greatly from the average and thus falsify the curve These outliers are often the result of in
294. roduct Settings gt A Edit gt Values Measurement 4 MyProduct Den Entering a remark for a measured value Measurement gt Table gt Edit gt In the table of measured values press one of the fields in the Remark Remark column Be Quick access via the field display 1 2 in Measurement mode Calling the settings dialog for the display fields You can also use this dialog to switch between the analog display and the statistics Measurement gt Display 1 Display 2 Press one of the two display panels gt Analog display gt Settings Measurement gt Display 1 Display 2 z P gt Statistics gt Settings mm a 70 Moisture 100 Quick access via the fields Display 1 2 in Calibration mode Calling the dialog Moisture calibration type Density calibration type Calibration gt Moisture Density gt Press the Display 1 field Type settings gt Simple or expert oe Cakbration Type Ku Corrections 0 132 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Shortcuts Calling the dialog Moisture options Density options Calibration gt Moisture gt Options Press the Display 2 field Calibration gt Density gt Options Ka Shortcuts in Compression test mode Calling the Measurement settings dialog Service gt MWTest gt Press the Display 2 field Compression test gt Measure Settings neihr 4 97 ensiy 4 9 Calling the Compression test properties dialog
295. rodukte angezeigt werden nutzen Sie die Schaltfl chen fur die Navigation Details auf Seite 212 3 Dr cken Sie auf bernehmen Die Kalibration kann nun f r das gew hlte Produkt durchgef hrt 2 oder bearbeitet werden Feuchte Kalibration Die schrittweise Beschreibung der Kalibration finden Sie im Abschnitt Kalibrieren Details auf Seite 172 Kalibration im Labor Die Tabelle wird zur Messung der Referenzwerte wie auch f r die Eingabe der Laborwerte aufge rufen Tabelle W hlen Sie Kalibration gt Feuchte Kalibration gt Tabelle um die Tabellenansicht der Kalibration zu erhalten Diese Ansicht w hlen Sie um Referenzwerte zu messen Laborwerte einzugeben oder um die Kalibration zu bearbeiten 1 Dr cken Sie auf die Betriebsartanzeige Kalibration Feuchte oder das Tabellen Symbol um zur Tabellenansicht umzuschalten Das Men hat folgende Men punkte Tabelle gt Bearbeiten Details auf Seite 226 Tabelle gt Einstellungen Details auf Seite 229 Tabelle gt Drucken Details auf Seite 229 Tabelle gt Export Details auf Seite 230 O Hinweis Wenn de Tabelle mehr als 10 Werte enth lt nutzen Sie die Schaltfl chen zur Navigation Details auf Seite 212 Tabelle gt Bearbeiten Werte Referenzwerte f r die vermessenen Proben werden hier in die Kalibrationstabelle eingetragen 1 W hlen Sie im Men Kalibration gt Feuchte Kalibration gt Tabelle gt Bearbeiten gt Werte W hlen Sie
296. rols on the touchscreen with your fingers Using a connected mouse and keyboard Using the mouse and keyboard of a connected PC See page 70 for an overview of on screen controls Using the touchscreen only for LMA321PA When you use the touch screen to operate the device you simply press the controls on the screen with your finger or with a special pen Caution Never touch the screen with sharp objects such as screwdrivers or ballpoint pens IN These can damage the screen You use input dialogs to enter letters and numbers page 124 To select a menu item or execute a command press the relevant element O Note The mouse cursor is always visible even if no mouse is connected The mouse cursor moves to the position touched on the screen Operating the device using a mouse and keyboard The device must be operated using a mouse and keyboard in the following cases LMAS16PA This device does not have an integrated touchscreen and must be operated using a mouse and keyboard since the externally connected monitor is not touch sensitive LMA321PA For administrative tasks or if the touchscreen is dirty it might be useful to connect a keyboard and mouse to the appropriately colour coded sockets on the rear of the device External PC If you are controlling the device using an external PC you operate it using the key board and mouse of the PC in question See Control via external PC Details on page 17 Deactivating the virtua
297. ronics SAG10CE016 LMA321PA 58 SOP 3 RD 045 fo2 lt ii Sartorius 2909 f mechatronics EG Konformit tserkl rung EC Declaration of Conformity Anhang 1 Annex 1 Liste der angewendeten harmonisierten Europ ischen Normen List of the applied harmonized European Standards 1 Richtlinie 2004 108 EG Directive 2004 108 EC EN 61326 1 2006 Elektrische Mess Steuer Regel und Laborger te EMV Anforderungen Teil 1 Allgemeine Anforderungen IEC 61326 1 2005 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 General requirements IEC 61326 1 2005 2 Richtlinie 2006 95 EG Directive 2006 95 EC EN 61010 1 2001 Sicherheitsbestimmungen f r elektrische Mess Steuer Regel und Laborger te Teil 1 Allgemeine Anforderungen IEC 61010 1 2001 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requirements IEC 61010 1 2001 AS GG A 2 SAG10CE016 LMA321PA 58 SOP 3 RD 045 fo2 EE Sartorius see e mechatronics Konformit tserkl rung Declaration of Conformity Sartorius AG Weender Landstr 94 108 37075 G ttingen Germany erkl rt dass das Betriebsmittel declares that the equipment Ger t Labor Feuchtemessger t Apparatus Laboratory moisture analyzer Modell Model LMA321PA 000U LMA3 16PA 000U bereinstimmt mit den Regelungen der Europ ischen Richtlinie in der heute g ltigen Fa
298. s Before you can use the Print command on the measuring device you must connect a printer and set it up using the printer configuration This can be a printer available on the network or in the case of laboratory devices a directly connected USB printer In the case of measuring devices that are controlled via an external PC no printer entry needs to be created You can use all avail able printers on the external PC as is normal when using Windows O Note The Printer Configuration plug in is only available in English Add New Printer You use this function to trigger the creation of a new printer entry The system prompts you to enter a name for the new printer This name is used to display the printer once it has been created in TMV Once you press Apply you automatically go to the Printer Device tab where you can select the printer you want to use The list in the Device field shows all printers that are either connected directly to the measuring device using a USB cable and are switched on or that are available on the IP network You can use the Init function to search for connected printers again if for example a printer is only switched on after the dialog has been called up Once you press on Next you go to the Make Model Driver tab where you can check and change the printer manufacturer and model You then press on Add Printer to add the new printer to the list of TMV printers Set As Default The printer selected in
299. s f r das der Test durchgef hrt werden soll 4 Dr cken Sie auf bernehmen Der Verdichtungstest kann nun f r das gew hlte Produkt durch 2 gef hrt oder bearbeitet werden 5 Dr cken Sie auf das Feld Anzeige 2 und bestimmen Sie die Eigenschaften der Messung gt Seite 170 Legen Sie die Anzahl der Speicherpl tze f r Messwerte fest Legen Sie den Modus der Messung fest Bei Labormessger ten m ssen Sie die Option continously deaktivieren um die Messungen ein zeln wie in den Schritten 7 bis 10 beschrieben durchf hren zu k nnen 6 F hren Sie einen Leerabgleich durch 7 F llen Sie den Sensor langsam bis in der Kopfzeile ein Messwert erscheint 9 F llen Sie den Sensor weiter langsam und dr cken Sie wieder Start zum Speichern des Mess werts 8 Dr cken Sie auf Start um den Wert abzuspeichern 10 Wiederholen Sie diesen Vorgang bis der Sensor komplett gef llt ist Die Messergebnisse des Tests werden als Tabelle angezeigt Sie haben die M glichkeit einzelne Punkte der Messkurve durch unterschiedliche Symbole darzustellen oder einzelne Punkte der Messkurve zu l schen 11 Dr cken Sie auf die Zeile mit der Anzeige der Betriebsart Verdichtungs Test um zur grafi schen Darstellung zu wechseln O Hinweis W hrend des Verdichtungstests werden in den Feldern Anzeige 1 Anzeige 2 wichtige Parameter des Tests angezeigt 28 sartorius 169 mechatronics WLM6009 a10081 LMA316PA LMA321PA
300. s All to print the entire table 3 Press Print The standard print dialog appears you can specify the print settings and trigger printing by clicking Print ca EE sartorius cece 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Taking measurements SS HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA 9 Other functions 9 1 Defining users with different access profiles For operation of the unit administrators can create different user records and assign different user rights to them This allows them to allocate various levels of restrictions to the access to system settings and special tasks such as calibration hard empty sensor adjustment and thus to make some functions available to qualified persons only One user can be defined as the default user If this is the case the device will skip the password query and automatically load the access profile of the default user no matter which user was logged on when the device was turned off the last time If a default user is not defined the Login dialog will be displayed immediately after starting the software There are six different user levels The rights of one level also include the rights of the lower levels The lowest level 0 only enables measuring whilst the highest level 5 provides access to all settings Menu items for which a user does not have authorization are not displayed to the user in question Some users may not be able
301. s Fehlers wird in Block 3 angegeben Fehlercode 4 weist auf RE Fehler hin die genaue Art des Fehlers wird in Block 2 angegeben Block 2 zeigt an wenn Messungen m glich sind aber au erhalb des freigegebenen Bereichs lie gen e Wird in Block 3 ein Fehlercode angezeigt sind technisch keine Messungen m glich z B weil keine Kabelverbindung zum Sensor besteht Pr fen Sie die Kabelverbindungen und kontaktieren Sie im Zweifelsfall bitte den Service Block 1 MV oder MWT Measurement value Allgemeine Information zur Fehlerart Block 2 RE Range error Messung au er Bereich Block 3 MT Mess Task Messung nicht m glich Die folgende Liste zeigt welche Aktion zur Abhilfe bei einzelnen Fehler notwendig ist Fehlercode Ursache und Abhilfe MV RE MT 1 0 0 Sensor ist leer daher keine Messung m glich 2 0 2 Die Startfrequenz des Sensors ist zu grok e Legen Sie eine kleinere Startfrequenz fest im Dialog Sensormodus Aufruf ber den Men befehl Systemeinstellungen gt Konfiguration gt Sensormodi gt Bearbeiten gt Werte e oder w hlen Sie einen anderen Sensormodus im Dialog Produkteigen schaften Aufruf ber den Men befehl Produkteinstellungen gt Bear beiten gt Werte SHE sartorius 271 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz Fehlercode Ursache und Abhilfe 2 0 3 Die Startfrequenz des Sensors ist zu klein e Legen Sie eine gr ere Startfrequenz fest
302. s ein Nach Dr cken auf bernehmen steht der neue Sensormodus f r Produkte zur Verf gung Die Anforderungen haben sich durch Ver nderungen am Sensor z B Verschmutzung oder neue bzw ver nderte Proben f r die die vorhandenen Modi nicht ausreichen ver ndert In die sen F llen kopieren Sie einen vornandenen Sensormodus und ndern in dieser Kopie die ent sprechenden Parameter W hlen Sie den Befehl Systemeinstellungen gt Konfiguration gt Sensormodi gt Bearbeiten gt Kopieren Markieren Sie in der Tabelle einen geeigneten Sensormodus den Sie als Basis f r Ihren neuen Sensormodus verwenden m chten und dr cken Sie auf Kopieren In der Liste wird eine Kopie des Sensormodus mit demselben Namen angelegt W hlen Sie nun den Befehl Systemeinstellungen gt Konfiguration gt Sensormodi gt Bearbei ten gt Werte Markieren Sie in der Tabelle den neu kopierten Sensormodus und dr cken Sie auf Werte ndern Sie im Dialog Sensormodus die gew nschten Parameter Zur besseren bersicht soll ten Sie unbedingt im Feld Name die Bezeichnung f r den Sensormodus ndern oder neu verge ben Nach Dr cken auf bernehmen steht der neue Sensormodus f r Produkte zur Verf gung Welche Parameter dabei wie zu ndern sind h ngt von ge nderten Anforderungen ab Beispiel Messen Sie ein Produkt mit einer h heren Feuchte oder Dichte vergr ern Sie den Suchbereich durch einen geringeren Wert f r die Startfrequenz Dr cken S
303. s one of the tabs to open the page in question If you have changed settings then choose Submit to close the dialog and accept the changes In some cases you have to restart TMV before the changes take effect EE sartorius a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference MW device Process laboratory TMV can be used to control process and laboratory measuring devices and the operating proce dure during measurement is distinguished on the basis of the setting made here If Process is chosen TMV is set up for continuous measurement during an ongoing process and ifLaboratory is chosen it is set up for single measurements in the laboratory The pre defined setting is appropriate for the device in question and must not be changed since doing so can stop the system from working However in principle it would be possible to use a laboratory device with a planar sensor for process measurement using this setting for example Auto start only for process measurement x Option activated The measuring device starts taking measurements automatically after being switched on el Option deactivated After switching the device on you have to start measuring manually in TMV by pressing the Start button Simulation You may wish to run the software in simulation mode for presentation purposes You select this option here Temperature Product temperature These settings influence t
304. s rights to change these settings You can copy any sensor mode A copied mode is pasted into the table with its original name Copying a mode allows you to create similar entries very easily Select Copy from the Edit menu The table is now displayed in copy mode i e the controls page 70 for selecting one or more rows are displayed at the bottom Press a row This selects the sensor mode Press Copy Selected rows are copied and inserted into the table as new values 3 Press Close The copy process is complete SCH Create O Note You need to be logged on with at least level 4 access rights to change these settings 1 Select New from the Edit menu The Sensor mode dialog is displayed 2 Press Library Select a sensor mode from the list The properties of the selected sensor mode are copied to the dialog box and can now be edited Library Press an input field The Numerical input Details on page 125 or Text input Details on page 124 dialog appears Enter the required parameters and specify a name for the new sensor mode VG 4 Press Apply This creates the sensor mode EE sartorius 111 a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference A 112 Settings The Settings dialog appears You can customize the depiction of the table for displaying the product settings here See Settings for tables Details on page 126 Print You can print t
305. schalten einige Minuten bevor Sie messen Das Ger t hat dann die optimale Betriebstemperatur erreicht Messen Falls das Ger t nicht oberhalb der Tabelle die Betriebsart Messung anzeigt w hlen Sie den Men punkt Messung Cursor 715 Coffee gew hltes Produkt 0 000 7 0 Feuchte 10 0 Pr fen Sie der Zeile darunter ob das richtige Produkt ausgew hlt ist Wollen Sie ein anderes Pro dukt messen dr cken Sie Messung gt Produktauswahl und w hlen das gew nschte Produkt Starten Sie eine Messung indem Sie auf das Symbol Start dr cken Folgen Sie den Anweisungen in der Statuszeile Falls sich noch ein Produkt im Sensor befindet wird die Meldung Bitte leeren angezeigt Ent nehmen Sie das Produkt bzw setzen Sie einen leeren Messbecher ein Bef llen Sie den Sensor sobald Bitte f llen angezeigt wird und f hren Sie ggf den Tempera tursensor Pt 100 ein Die Messung wird vom Ger t durchgef hrt und der Messwert wird ange zeigt Speichern Sie das Ergebnis durch Dr cken der Speichern Schaltfl che Je nach Sensor oder Systemeinstellung werden Sie eventuell aufgefordert die Probe zu drehen oder eine neue Probe einzugeben Wiederholen Sie dann die Schritte 6 bis 8 Der Dialog zur Eingabe einer Bemerkung wird angezeigt Hier geben Sie z B die Nummer der Probe ein und dr cken anschlie end auf bernehmen Mes su ng a Betriebsart Feuchte Offset Messwerte drucken Ist ein Drucker angeschlossen k nnen die Mes
306. schluss Temperatursensor Pt 100 Anschl sse f r Maus und Tastatur PS 2 sowie VGA Bildschirm Umgebungsbedingungen Verwendung in Innenr umen H he bis zu 2 000 m Netzspannungs Schwankungen bis zu 10 der Nennspannung Uberspannungskategorie Il Verschmutzungs grad 2 Lagertemperatur 10 C bis 60 C Probentemperatur 0 C bis 70 C autom Temperaturkompensation H chste relative Luftfeuchte 80 f r Temperaturen bis zu 31 C linear abnehmend bis 50 relativer Luftfeuchte bei 40 C Messbereich 0 1 85 in w hlbarenTeilbereichen Reproduzierbarkeit 0 05 Standardabweichung bei 10 facher Messung Messzeit lt 1 Sekunde Produktspeicher 40 Standard optional 20 oder 200 Datensicherung Flash Speicher Abmessungen und Gewicht 425x335x500 mm BxHxT Gewicht 10 kg Weitere Leistungsmerkmale und Spezifikationen auf Anfrage 192 EE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Abhilfe bei Problemen 11 Abhilfe bei Problemen Diese bersicht hilft Ihnen Probleme bei der Arbeit mit dem Ger t zu beseitigen Wenn das Ge rat wie erwartet arbeitet trotzdem jedoch anscheinend fehlerhafte Messwerte angezeigt werden lesen Sie bitte Was Sie beim Kalibrieren beachten m ssen Details auf Seite 165 Fehlermeldungen Details auf Seite 271 Problem Abhilfe Gerat startet nicht Nicht alle beschriebenen Stromversorgung pr fen Gegebenenfalls Ger t anscha
307. sdaten bertragen Gen Generator sendet die Mikrowellen an den Sensor Det Detektor empf ngt die Mikrowellensignale Achtung Es m ssen jeweils die gleichnamigen Anschl sse beider Ger te miteinander verbunden werden Zur leichteren Zuordnung sind die MW Gen Anschl sse gr n markiert ebenso das hierf r ver wendete Mikrowellenkabel Sensor 1 2 Optionale Verbindung zum Sensor bei Ger ten der Black Line Serie Die Sensoren bermitteln ber diese Schnittstelle die Konfigurationsdaten sowie ggf Temperaturmessdaten Temperatursensor Thermometer Symbol Es besteht die M glichkeit zus tzlich einen Temperatursensor Pt 100 zum Ermitteln der aktu ellen Temperatur Werte anzuschlie en Das Pt 100 kann entweder alternativ zu einem in den Sensor integrierten Temperatursensor verwendet werden oder bei Sensoren die nicht ber einen eingebauten Temperatursensor verf gen Ethernet Netzwerk Symbol ber ein Netzwerk Kabel kann die Auswerteeinheit mit dem Firmennetzwerk verbunden werden Auf diese Weise kann ber einen externen PC mit einer Windows Version der Software die Auswerteeinheit gesteuert werden Hinweis Die Netzwerkeinstellungen IP Adresse usw des Ger ts werden unter System einstellungen gt Konfiguration gt Kommunikation gt Dieses TMV vorgenommen Zugriff nur mit den entsprechenden Benutzerrechten Bedienvorg nge direkt an der Auswerteeinheit haben Vorrang vor Befehlen die ber die Windows Version auf
308. sehenen PS2 Anschl sse verwendet werden Beim Anschluss von Tastatur oder Maus ber USB kann nicht garantiert werden dass die Software des LMA321PA diese Ger te erkennt SHE sartorius 151 cece 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Produktbeschreibung 3 3 152 Lieferumfang Grunds tzlich geh ren in der Laborversion zum Lieferumfang die Auswerteeinheit mindestens ein Sensor USB Stick zum bertragen der Daten sowie zum Aufspielen von Software Updates die zur Verbindung notwendigen Mikrowellen Sensor Netz und Ethernetkabel Crossover Temperatursensor Pt 100 Tastatur zus tzlich beim LMA321PA Stift zur Bedienung des Touchscreen Optionale Komponenten CD mit der Software TMV IR Temperatursensor Multiplexer zum Anschluss eines weiteren Sensors integriert Hinweis Die Auswerteeinheit kann auch ohne Sensor geliefert werden wenn bereits ein Sensor vorhanden ist Der weitere Lieferumfang ist abh ngig vom Einsatzbereich Informationen hierzu entnehmen Sie bitte Ihren Bestellunterlagen HE sartorius coe mechatronics WLM6009 a10081 LMA316PA LMA321PA 4 Inbetriebnahme 4 1 Hinweise zum Aufstellen Die Mikrowellenkabel k nnen als Sonderanfertigung maximal eine Lange von 3 Metern haben die Standardversion hat eine Lange von 1 Meter Die Auswerteeinheit muss also entsprechend dicht beim Sensor aufgestellt werden Die hinteren Ger tef e dienen zum Abstellen des LMA316PA LMA
309. sen bestimmen Sie hier die Temperaturwerte die den Eingangswerten 0 mA alternativ 4 mA und 20 mA entsprechen Sensortemperatur Diese Einstellungen werden f r die Temperaturkorrektur des Leerzustandes des Sensors ben tigt Die Einstellm glichkeiten entsprechen denen f r die Produkttemperatur Analogausg nge Neben den digitalen Ausg ngen sind die Prozessmessger te mit einer unterschiedlichen Anzahl von Analogausg ngen ausgestattet Die Anzahl der Analogausg nge h ngt von der Ausbaustufe der Ger te d h der Anzahl der eingebauten Platinen ab siehe Technische Daten ab Seite 192 ERE sartorius a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz ei Angezeigt werden alle eingebauten Platinen Es k nnen bis zu 4 Platinen konfiguriert werden Bei der Konfiguration ist darauf zu achten dass nur tats chlich verkabelte Ausg nge Ports genutzt werden Die Analogausg nge liefern dann als Signale 0 mA alternativ 4 mA und 20 mA f r die einge stellten Prozentwerte sowie Werte in mA beim Ger testart und f r Messpausen Der Startwert darf nicht 0 sein da sonst schon beim Ger testart ein Warnsignal erzeugt wird Welche Platinen und Ports Sie verwenden und welche Signale ausgewertet werden sollen h ngt von der Konfiguration Ihrer Anlage ab Konfiguration Das Men hat folgende Men punkte Sensormodi Details auf Seite 251 Kommunikation Details auf Seite 254 MW
310. ser link 1 x No 3 Data over server IP address 172 28 20 28 9 Yes 4 Max freg dev of ES adjust MHz 0 01 2 Yes 5 Maximum emptying time sec 30 2 Yes 6 Maximum filling time sec 30 2 es 7 Maximum measurement time sec 28 2 Yes 8 Temperature measurement pause sec 5 2 Yes 9 Wait for stable temperature sec x No gj Edit Hinweis Welche Makros vorhanden sind ist abh ngig vom Typ des Messger ts Der Dialog zur Makroeinstellung ist nur in englischer Sprache verf gbar Markieren Sie das Makro dessen Einstellungen Sie ndern wollen und dr cken Sie auf Edit Hinweise zur Bearbeitung Werte Spalte Value k nnen nur bearbeitet werden wenn die jeweiligen Makros akiviert sind Yes in der Spalte Available Makros die f r das Funktionieren des Systems zwingend notwendig sind k nnen nicht deakti viert werden Der Eintrag Yes in der Spalte Available wird grau dargestellt HE sartorius seg x mechatronics WLM6009 a10081 Makro Bezeichnung LMA316PA LMA321PA Bedienoberfl che Referenz Erlauterung Auto ES adjust Der Leerabgleich bei Prozessmessgeraten wird automa tisch durchgef hrt wenn der Sensor leer ist Das Intervall in dem diese Leermessungen durchgef hrt werden kann unter Measurement interval festgelegt werden Data over modbus TCP Data over ser link Data over server IP address Angaben f r das Versenden von Messdaten ber die seri elle Schnittstelle bzw Et
311. sonderten Dokumentationen die mit dem den Sensor en geliefert wer den sowie das Technische Handbuch Anwendungsberatung E Mail pmd300 support sartorius com Telefon 49 0 551 308 3160 Telefax 49 0 551 308 3495 SHE sartorius 141 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bevor Sie beginnen 1 4 d SEPP 142 Hinweise zur Online Hilfe Im Kapitel Bedienoberfl che Referenz Details auf Seite 205 finden Sie Informationen zu allen Funktionen entsprechend der Men s gegliedert Diese Informationen sind w hrend der Arbeit am Touchscreen online verf gbar Um Information zum aktiven Men punkt zu erhalten dr cken Sie auf die Schaltfl che f r Hilfe Schreibkonventionen in dieser Dokumentation In dieser Dokumentation sind Textstellen die besondere Aufmerksamkeit erfordern entspre chend hervorgehoben GEFAHR Das Warndreieck mit dem Ausrufungszeichen und dem Wort GEFAHR warnt Sie vor m glichen schweren Verletzungen oder Verletzungen mit Todesfolge Vorsicht Das Warndreieck mit dem Ausrufungszeichen und dem Wort Vorsicht warnt Sie vor m glichen leichten Verletzungen oder Sachsch den Achtung Das Warndreieck mit der zerbrochenen Diskette warnt Sie vor Datenverlust oder der Gefahr feh lerhafte Daten zu erzeugen Voraussetzungen Auf diese Weise werden Voraussetzungen gekennzeichnet die vor der Durchf hrung der n chsten Arbeitsschritte erf llt sein m ssen Hinweis So gekennzeic
312. sor mit dem Referenzk rper bzw legen Sie bei Planarsensoren den Refe renzk rper auf den Sensor 5 F hren Sie die Messung en durch und vergleichen Sie diese mit den auf dem zugeh rigen Zer tifikat angegebenen Werten 6 Falls die Werte nicht innerhalb der auf dem Zertifikat angegebenen Grenzen liegen wenden Sie sich bitte an den Service von Sartorius SHE sartorius 203 cece x mechatronics WLM6009 a10081 LMA316PA LMA321PA Weitere Funktionen 204 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA 13 Bedienoberflache Referenz In diesem Kapitel wird die Bedienoberflache Touchscreen der Software TMV beschrieben Sie finden hier zu jedem Men punkt und allen Dialogen Erkl rungen In den vorhergehenden Kapi teln wird an entsprechender Stelle auf diese Referenz verwiesen Diese Informationen finden Sie auch in der Online Hilfe Die Bedienoberflache ist in verschiedene Bereiche gegliedert Schaltfl chen Statuszeile Ansicht Men A Feuchte 9 19 Dichte 4 19 26 8 C 12 Betriebsart Ce p Nee 10 Eege e Anzeige 1 2 rodukt 3 Cigarettes CY 41 0 000 euc 00 H Offset Feuchte i emerkung Feuchte MWFeuchte Dichte EE 12 25 2009 03 20 12 24 37 9 02 0 258 3 30 13 26 2009 03 20 122438 9 01 0 290 3 28 14 27 2009 03 20 12 24 41 9 04 0 269 3 36 15 28 2009 03 20 12
313. ss where the moisture value of the product is known to be higher or lower than this value The offset is defined in the product parameters 1 If necessary select the product for which you want to enter an offset 2 Press Off moisture Calibration calc Mie linear rections 0 Calibration Moisture 3 Cigarettes CY 41 RMS 1 680 Values 3 Off moisture Correlation 0 995 3 Enter a moisture offset value using the keyboard and press Apply O Note If you want to set a density offset as well as a moisture offset you can do so in the Product settings dialog called by choosing Product settings gt Edit gt Values The offset is an absolute value If your offset is 0 5 and the measured values are 10 and 11 the system displays 10 5 and 11 5 instead Likewise for a density offset the value of 10 5 g m is shown instead of 10 g m 2 sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA Calibration Adapting the calibration curve O Note The 1st display and 2nd display panels show parameters and settings during the calibration process Calibration Moisture Calibration calc Correlation 0 995 3 es Type linear RMS 1 680 3 Cigarettes CY 41 oi Corrections 0 Values 8 1st display 2nd display Calibration type Values 1 Press 1st display to open the Calibration type dialog simple You can open another dialog with expert settings from this dialog or usin
314. ssung complies with the regulations of the European Directive in the today valid version Richtlinie 2002 95 EG Zur Beschr nkung der Verwendung bestimmter gef hrlicher Stoffe in Elektro und Elektronikger ten Directive 2002 95 EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment sofern das Betriebsmittel gekennzeichnet ist mit provided that the equipment is marked with Sartorius AG G ttingen 2010 08 10 d J MO te A LE AA Dr Reinhard Baumfalk Dr Dieter Klausgrete Leitung Entwicklung Leitung International Certification Management Mechatronik Mechatronik Vice President R amp D Head of International Certification Management Mechatronics Mechatronics SAG 10RoHS003 LMA321PA 58 SOP 3 RD 045 fo3 EE Sartorius mechatronics Konformitatserklarung Declaration of Conformity Sartorius AG Weender Landstr 94 108 37075 Gottingen Germany erklart dass das Betriebsmittel declares that the equipment Gerat Laborsensor Apparatus Laboratory sensor Modell Model LMA330RE 010B LMA330RE 010 LMA330RE 016 LMA330RE 020B LMA330RE 026 LMA330RE 026X LMA330RF 016 LMA330RH 040B LMA330RH 046 LMA330RH 050B LMA330RE 075B LMA330RH 096 bereinstimmt mit den Regelungen der Europ ischen Richtlinie in der heute g ltigen Fassung complies with the regulations of the European Directive in the today valid version Richtlinie 2002 95 EG Zur Beschr
315. sture Blue Density Yellow Temperature Green Red markings depict the user defined alarm range If the displayed value is in the alarm range the bar chart is shown in red Settings You call this dialog from the menu or by pressing the display Value Press the list field to select the measured values to be displayed 2 Choose from the following 2 sartorius a mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Moisture Density Temp temperature Scale Enter the lowest and highest scale values here Press the input field to display the Numerical input Details on page 125 dialog Values outside this range are still shown digitally but in this case the bar chart display is not indic ative of this Alarm The values for the lower and upper limits of the alarm range are displayed here These values are defined in the product properties gt page 103 Last Cursor Here select whether the displayed value is the current measured value Last or the value at the current cursor position Cursor Press Statistics to display statistics in the display panel See Statistics 3 Press Apply The values are displayed in accordance with the selected settings 82 HE sartorius coe mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference ge Statistics Il Instead of an analog display each display panel can be used to display a statistical va
316. suring device each time thereby enabling parallel processing on all measuring devices Determining the IP address of the measuring device To determine the IP address of the measuring device proceed as follows Select System settings gt Configuration gt Communication gt This TMV on the device The This TMV dialog for this measuring device is displayed and you can read the IP address in the Address field Changing the IP address of the measuring device If you intend to add the measuring device to an existing network the measuring device is to be allocated a suitable network address Generally the measuring device s IP address is set by the service personnel via the service interface at installation in accordance with your demands If however the measuring device was reset to factory settings gt page 61 the device is real located its standard address 172 28 1 1 Network access is no longer possible The measuring device must be re assigned the desired address via direct connection For measuring devices with touchscreen LMA321PA or external monitor and keyboard LMA316PA this change can be implemented directly on the device Select System settings gt Configuration gt Communication gt This TMV on the device Enter the IP address in the This TMV dialog and state further network connection details if appli cable Contact your network administrator for further information on your network Finally press on Apply
317. swerte ausgedruckt werden Dr cken Sie im Men Messung gt Tabelle gt Drucken Markieren Sie in der Tabelle die Werte die gedruckt werden sollen oder dr cken Sie auf Alle wenn die komplette Tabelle gedruckt werden soll Dr cken Sie auf Drucken Sie erhalten den Standard Druckerdialog Legen Sie die Druckereinstellungen fest und dr cken Sie auf Drucken Ger t ausschalten Schalten Sie das Ger t mit dem Ein Ausschalter auf der R ckseite aus Die Bediensoftware muss nicht vorher beendet werden HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA 9 Wartung und Pflege 9 1 Software Update O Hinweis Falls Sie das Messger t ber einen externen PC steuern m ssen Sie nach einem Software Update am Messger t die Software auf dem externen PC ebenfalls aktualisieren Sie erhalten Software Updates als zip Archivdatei von Sartorius 1 Entpacken Sie das zip Archiv komplett in einen neu angelegten leeren Ordner auf einem PC Achten Sie dabei darauf dass Dateipfade und Ordnerstruktur der Dateien erhalten bleiben 2 Kopieren Sie alle entpackten Dateien einschlie lich der Ordnerstruktur auf den mit dem Messge r t mitgelieferten USB Stick Schalten Sie das Ger t mit dem Hauptschalter an der R ckseite des Ger tes aus 4 Stecken Sie den USB Stick in einen der USB Anschl sse Schalten Sie das Ger t mit dem Hauptschalter an der R ckseite des Ger tes wieder ein Das Update wird automatisch erkannt und i
318. swerte ermittelt zwischen den Messungen muss der Messbeh lter mit dem Produkt gedreht werden Prozessmessung in einem Produktionsablauf Es werden in bestimmten Abst nden mehrere Messwerte ermittelt empfohlen mind 6 Messun gen zu denen dann die entsprechenden Proben vom Produkt entnommen werden m ssen kontinuierliche Online Messung z B bei Sch ttgut das ber ein Flie band am Sensor vorbei l uft Bypass Messung bei der regelm ig fest definierte Probenmengen zur Messung vom Haupt strom in den Sensor abgezweigt werden Nach der Messung wird die Probe automatisch wieder in den Hauptstrom zur ckgef hrt und der Sensor gereinigt HE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Kalibrieren Kalibration fur Einfach und Mehrfachmessungen Labor O Hinweis F r optimale Kalibrationsergebnisse beachten Sie bitte die Tipps zur Kalibration auf Seite 165 1 Schalten Sie ggf das Ger t ein Der Schalter befindet sich an der R ckseite des Ger ts Wenn das Ger t bereits in Betrieb ist stoppen Sie laufende Messungen 2 W hlen Sie den Men punkt Kalibration W hlen Sie hier den Men punkt Produktauswahl Gesch tzte Produkte sind mit einem Schloss gekennzeichnet Bei einem gesch tzten Produkt A kann die Kalibration nicht geandert werden 4 W hlen Sie im Dialog Produktauswahl das gew nschte Produkt und klicken Sie auf Uberneh men 5 W hlen Sie im Men Kalibration ent
319. system displays it now Press Start If there is still a product in the sensor the system issues a Please empty prompt Remove the product or insert an empty measuring cup depending on the sensor used The system issues an Empty sensor adjust message The device tells you that it has detected an empty sensor Note If you are asked to empty the sensor when it is already empty press the ES empty sensor adjust control This tells the sensor that it is empty the system then compensates for changes that may have taken place on the sensor such as the accumulation of dirt or thermal changes The system issues a Please fill message Fill the sensor If a sensor with a measuring cup is used ensure that it is completely filled When filling the meas uring cup make sure that there are no large cavities If a planar sensor is being used ensure that the sensor is evenly covered with the product Optional Insert the PT 100 temperature sensor into the sample The measurement is carried out by the device In the case of simultaneous temperature measurement the measurement is taken once a con stant temperature value is recorded Note When a reference value is measured both the moisture and the density are recorded However calibration is carried out separately for the two measurement parameters Depending on the sensor used and the system settings you are asked to rotate the sample or to place a new sample into the senso
320. t Daf r bietet die Mikrowellen Resonanzmethode besondere Vorteile wie Schnelligkeit Farb und Dichteunabh ngigkeit Genauigkeit Bestimmung der Kernfeuchte und Unabh ngigkeit von Oberfl cheneffekten lonen lonische Bestandteile k nnen bei vielen Verfahren die Messung beeinflussen Die Sartorius Methode nutzt den polaren Charakter des Wassermolek ls und besitzt daher eine sehr hohe Selektivit t bei der Detektierung von Wasser Kalibration Die Mikrowellen Resonanzmethode liefert ein mit dem Wassergehalt korreliertes Messsignal So m ssen die gemessenen Mikrowellenwerte den mit einer Referenzmethode direkte Methode ermittelten Feuchtewerten einmalig zugeordnet werden Das System ermittelt dann automatisch eine Regressionsfunktion Die Kalibration ist sehr einfach men gesteuert durchzuf hren Es besteht die M glichkeit zwischen linearer und nichtlinearer Polynom Kalibration zu w hlen Kernfeuchtebestimmung Im Vergleich zu anderen Methoden bestimmen die Sartorius Ger te den gesamten Gehalt des physikalisch gebundenen Wassers Oberfl chen und Kernfeuchte da die Mikrowellen die gesamte Probe durchsetzen Langzeitstabilit t Aufgrund der Messung zweier unabh ngiger Parameter gegen einen stets neu bestimmten Null punkt Leerzustand ndern sich die Kalibrationen nicht durch u ere Effekte Leerabgleich Durch einen Leerabgleich teilen Sie dem System mit dass der Sensor leer ist Leer kann ggf auch bedeuten
321. t Dr cken Sie auf Zur ck um die jeweils oben liegende Men ebene auszu A blenden Gr Wenn das Men nicht ge ffnet ist wird statt der Schaltfl che Zur ck die Schalt D fl che Chronik eingeblendet Chronik Dr cken Sie diese Schaltfl che um die zuletzt aufgerufenen Men punkte ange zeigt zu bekommen und gegebenenfalls aufzurufen Dr cken Sie die Schaltfl che ein zweites Mal um die Liste wieder auszublenden Verwenden Sie zum Ber hren des Touchscreens keine scharfkantigen Gegen As st nde wie Schraubenzieher Kugelschreiber o A Diese k nnen die Oberfl che besch digen Anzeige Die Anzeigefl che dient zur Anzeige der Messwerte F r Verwaltungsaufgaben werden hier jedoch andere Bedienelemente oder Tabellen angezeigt Eine Beschreibung finden Sie jeweils unter den entsprechenden Men punkten Allgemeine Hinweise Cursorposition und Markierungen In der Anzeige unabh ngig von der Form ist ein Cursor definiert Dieser steht an einer von Ihnen bestimmbaren Position Die Werte der Messung an der der Cursor steht k nnen parallel zu den Werten der aktuellen Messung z B in der analogen Anzeige dargestellt werden ERE sartorius e H mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz Die Cursorposition wird in der Anzeige rot dargestellt rote Umrandung in der Tabelle rote Linie in der Grafik Die Cursorposition zeigt nicht notwendigerweise die aktuelle letzt
322. t Tabelle gt Einstellungen Details auf Seite 216 individuell angepasst werden Spalten k nnen ausgeblendet werden Sie bestimmen hier ob die Tabelle sortierbar oder ob alternativ die Spalten verschiebbar sind 2 Nutzen Sie die Schaltfl chen f r die Navigation Details auf Seite 212 um weitere Werte der Messreihe anzuzeigen 3 Dr cken Sie auf die Betriebsartanzeige Messung oder das Tabellen Symbol um zur grafischen Darstellung umzuschalten 4 Zum Starten und Stoppen der Messung sowie zur Probeentnahme und zum Leerabgleich nutzen Sie die Schaltfl chen zur Messung Kalibration Details auf Seite 210 Cursorposition festlegen 5 Dr cken Sie auf eine Zeile Die Zeile ist markiert und wird rot umrandet dargestellt Bei Wechsel zur grafischen Darstellung Seite 218 bleibt die Cursorposition erhalten O Hinweis Dr cken Sie einmal auf die Schaltfl che Zum Ende Die Schaltfl che bleibt gedr ckt das hei t blau hinterlegt Nun wird der zuletzt gemessene Wert in der untersten Zeile angezeigt Die Tabelle wird laufend aktualisiert Bearbeiten Bemerkung EI Sie k nnen zu ausgew hlten Eintr gen in der Tabelle eine Bemerkung eingeben Nachdem Sie auf Bemerkung gedr ckt haben stehen entsprechende Schaltfl chen zur Verf gung Lesen Sie dazu Schaltfl chen Messung Kalibration Details auf Seite 210 1 Markieren Sie entweder einen Eintrag einen Block oder alle Eintr ge F r alle markierten Eintr ge wird dieselb
323. t am unteren Rand sehen Sie die Schaltfl chen Seite 210 zum Markieren einer oder mehrerer Zeilen 1 Dr cken Sie auf eine Zeile um diese zu markieren dh 2 Dr cken Sie auf die Schaltfl che Drucken Das weitere Vorgehen ist abh ngig davon ob der Drucker direkt am Messger t angeschlossen ist oder Sie von einem externen PC aus arbeiten 3 Dr cken Sie auf Schlie en Das Drucken der Werte ist beendet Lo Export Die Tabelle wird im Format csv exportiert und auf dem angeschlossenen USB Stick gespeichert EZ 1 Dr cken Sie auf Bearbeiten um den Dateinamen zu ndern O Hinweis Wenn Sie das Programm am PC nutzen erhalten Sie den Dialog Export Hier w hlen Sie einen Speicherort auf dem PC und hier ndern Sie gegebenenfalls den Namen der Exportdatei O Hinweis Microsoft Excel 2003 Das weit verbreitete universelle Exportformat csv ist f r Excel 2003 nicht richtig zu interpretieren Benennen Sie die csv Datei in txt um und importieren Sie sie in Excel 2003 mit der Importfunktion Einlesen O Hinweis F r diese Funktion m ssen Sie mit Zugriffsrechten mindestens der Stufe 4 angemeldet sein ber diese Funktion k nnen die Sensormodi von den meisten Sensoren eingelesen werden wenn diese ber ein Datenkabel mit dem Ger t verbunden sind SHE sartorius 253 seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz 254 x Die Funktion wird genutzt wenn das Ein
324. t the Measurement menu item The LMA321PA automatically starts with the product which was measured last If you intend to measure a different product you are required to specify this product first proceed with step 5 if the desired product was already selected Press the product name The Product choice Details on page 73 dialog appears In the table select the row containing the product for which you want to take measurements Press Apply Press Start If there is still a product in the sensor the system issues a Please empty prompt Remove the product or insert an empty measuring cup depending on the sensor The device briefly displays Empty sensor adjust followed by Fill sensor Note If you are asked to empty the sensor when it is already empty press the ES adjust empty sensor adjust control and then choose Hard This tells the sensor that it is empty the system then compensates for changes that may have taken place on the sensor such as the accumulation of dirt or thermal changes You may have to log in again with a user with appropriate user rights to carry out the empty sensor adjust see page 30 Fill the sensor If a sensor with a measuring cup is used ensure that it is completely filled When filling the meas uring cup make sure that there are no large cavities Optional Feed the PT 100 temperature sensor into the sample Note As a rule the temperature should be taken into account for the calibration
325. t values for the required depiction Min Max Enter the lowest and highest values to be shown here 1 Press the input field to display the Numerical input Details on page 125 dialog Values outside this set range are excluded If this is the case for several sequential values the curve may not appear at all The vertical scaling cannot be modified directly from the graph Line The colour of the selected curve is displayed here You cannot change this colour Moisture Blue Density Yellow Temperature Green Alarm Here you specify the range within which measured values are to be considered acceptable The selected range is displayed in the graph and in the analog display page 68 Measured values outside this range trigger an alarm that can be evaluated elsewhere e g in production control show x Press the box to display the corresponding range No alarm range is defined Min Max The values for the lower and upper limits of the alarm range are displayed here These values are defined in the product properties gt page 103 1 Press Apply The graph is displayed in accordance with the selected settings Print You can print the graphical depiction of the measured values See page 53 for information on how to connect a printer From the menu select Measurement gt Graph gt Print The graph is printed as it appears on the screen HE sartorius seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA
326. tartet Ein Anmelden ist nicht notwendig Falls keiner der angelegten Benutzer als Standardbenutzer eingerichtet wurde werden Sie auf gefordert sich mit Benutzernamen und Passwort anzumelden Hinweis F r die Anmeldung bei der ersten Inbetriebnahme erhalten Sie gesondert einen Benut zernamen und das dazugeh rende Passwort Wir empfehlen Ihnen dieses Passwort anschlie end zu ndern um unbefugten Zugriff zu vermeiden siehe hierzu Seite 195 Empfehlung Warten Sie nach dem Einschalten m glichst einige Minuten bevor Sie die ersten Messungen durchf hren da das Ger t dann seine optimale Betriebstemperatur erreicht hat EE sartorius a eegg mechatronics WLM6009 a10081 LMA316PA LMA321PA Inbetriebnahme 4 5 4 6 Sartorius IS LMA321PA ausschalten Das LMA321PA k nnen Sie nach Beendigung Ihrer Arbeiten einfach ber den Ein Ausschalter auf der R ckseite des Ger ts ausschalten Die Bediensoftware muss nicht vorher beendet werden Soll lediglich die Bediensoftware neu gestartet werden dr cken Sie Service gt Reset Hierf r m ssen Sie mindestens mit Zugriffsrechten der Stufe 4 angemeldet sein Ausnahme Wird das LMA321PA ber einen externen PC gesteuert muss die dort laufende Bediensoftware durch Klicken auf das Schlie en Symbol in der Titelleiste beendet werden Sind Sie mit Zugriffsrechten der Stufe 4 und h her angemeldet k nnen Sie die Software alternativ auch ber den Befehl Service gt Schlie
327. te You can also display this dialog by pressing the first display panel calibration type corrections Simple This dialog enables the simple calculation of the calibration From the list field choose either the simple linear calibration type or the non linear calibration type which can consist of up to four segments Linear The calibration curve is a straight line Non linear The calibration curve is not necessarily a straight line Areas of the calibration curve may appear as curves Note Please note that for a more complex calibration type more measured values are required as would be expected Extremum In the case of the non linear calibration type you specify whether the curve is to have an extrem um here Select the Extremum option if you know that one of the values represents a top or bot tom value x Curve with extremum U Curve without extremum A Correction Specify whether and how a correction is to be carried out for the calibration curve here The cali bration process then takes variations concerning the temperature and or moisture of the samples into account in the manner specified The system issues a corresponding message if there are insufficient measured values to enable a sensible correction EE sartorius a 00 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference O Note Temperature and density variations can only be taken into account if correspon
328. ted Measured temperatures are not taken into account mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Density calibration See Calibration Details on page 35 for a step by step description of the calibration procedure Calibration in the laboratory The table is called up for measuring the reference values and for entering the laboratory values Table Select Calibration gt Density calibration gt Table to go to the calibration table view You call up this view to measure reference values enter laboratory values or edit the calibration HH 1 Press the Calibration Moisture mode display or the table symbol to switch to the table view This menu has the following sub items Table gt Edit Details on page 94 Table gt Settings Details on page 97 Table gt Print Details on page 97 Table gt Export Details on page 97 O Note Ifthe table contains more than 10 values use the navigation controls See Navigation Details on page 72 Table gt Edit Values The reference values for the measured samples are entered into the calibration table here 1 Inthe menu select Calibration gt Density calibration gt Table gt Edit gt Values Inthe submenu select whether you want to edit an individual entry remark reference density type etc or all values Remark Details on page 95 Reference density Details on page 95 Type Details on pa
329. ted by an arrow in the column header Press the row containing the name of the product to be calibrated Note Products with similar properties can reference the same calibration If a product references the calibration of a similar product corresponding information can be found in the Reference to calibration line In the case of products with their own calibration the Cal link column contains the entry self HE sartorius coe mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference O Note Press the navigation controls see Navigation Details on page 72 to view products you cannot see immediately 3 Press Apply The calibration for the selected product can now be created or edited Moisture calibration See Calibration Details on page 35 for a step by step description of the calibration procedure Calibration in the laboratory The table is called up for measuring the reference values and for entering the laboratory values Table Select Calibration gt Moisture calibration gt Table to go to the calibration table view This view is for measuring reference values entering laboratory values and editing the calibration 1 Press the Calibration Moisture mode display or the table symbol to switch to the table view This menu has the following sub items Table gt Edit Details on page 85 Table gt Settings Details on page 88 Table gt Print Details on page 88 Tabl
330. tekorrektur aktivieren x aktiviert Das Ergebnis einer Messung wird bei schwankenden Messtemperaturen entsprechend korrigiert g deaktiviert Es findet keine Temperaturkorrektur statt Inkrement 1 Geben Sie hier den Wert f r die Temperaturkorrektur ein I 2 Klicken Sie auf bernehmen um die Einstellungen zu bernehmen Grafik gt Drucken Die grafische Darstellung der Kalibration kann ausgedruckt werden Hinweise zum Anschluss eines Druckers finden Sie auf Seite 198 W hlen Sie im Men Kalibration gt Dichte Kalibration gt Grafik gt Drucken Die Grafik wird so wie sie am Bildschirm dargestellt wird ausgedruckt 240 2 sartorius coe mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz Typeneinst Typeneinstellung Hier bestimmen Sie den Typ der Kalibration Wahlen Sie zwischen Einfach Experte auto O Hinweis Sie erhalten den entsprechenden Dialog auch wenn Sie auf das Feld Anzeige 1 Kalib ration Typ Korrekturen dr cken Einfach Der Dialog erm glicht ein einfache Berechnung der Kalibration 1 W hlen Sie aus dem Listenfeld entweder den einfachen Typ linear oder den Kalibrationstyp nichtlinear der aus einem oder aus bis zu vier Segmenten bestehen kann linear Die Kalibrationskurve ist eine gerade Linie nichtlinear Die Kalibrationskurve ist nicht unbedingt eine Linie Gegebenenfalls werden einzel ne Zonen der Kalibrationskurve durch Kurven dargestel
331. teln der Referenzwerte Die Kalibrations Messungen mit dem LMA3xxPA PMD3xxPA m ssen an genau den Proben erfolgen von denen auch die Referenzfeuchte im Labor mit einem direkten Verfahren bestimmt wird Die Materialfeuchte der Proben darf sich zwischen Kalibrationsmessung und Feuchtewertermitt lung im Labor nicht ndern d h die Vergleichsmessung im Labor sollte zeitnah m glichst sofort erfolgen Dies gilt insbesonders wenn die Temperatur der Probe ber der Raumtemperatur liegt bei hygroskopischen Stoffen bei Stoffen die Feuchte abgeben Heisse Proben m ssen in feuchte undurchl ssigen geschlossenen Beh ltern abk hlen bevor die Referenzmessung durchgef hrt wird Anzahl der Kalibrationspunkte F nf Kalibrationspunkte mit unterschiedlicher Feuchte sind in der Regel erforderlich Zwei Punkte gen gen unter der Voraussetzung dass HE sartorius 165 seg mechatronics WLM6009 a10081 6 2 166 LMA316PA LMA321PA Kalibrieren ein sehr genaues Labor Vergleichsverfahren angewendet wird und die Kalibrationspunkte weit auseinander liegen Wenn das Labor Vergleichsverfahren unsichere Werte liefert f hren Sie entsprechend f r mehrere Kalibrationspunkte Messungen durch Der statistische Fehler kann so genauer ermittelt und entsprechend ber cksichtigt werden Nichtlineare Kalibrationen die gegebenenfalls in mehrere Segmente unterteilt werden ben tigen entsprechend mehr Kalibrationspunkte
332. ten f r die Kalibration wird die Kurve automa tisch neu berechnet CT deaktiviert Zur Neuberechnung der Kurve m ssen Sie ab jetzt auf die Anzeige 1 klicken Deaktivieren Sie diese Option wenn Sie noch umfangreiche Bearbeitungen an den Werten vornehmen So k nnen Sie schneller arbeiten da der Berechnungsvorgang immer eine gewisse Zeit ben tigt Wenn einzelne Werte entfernt oder ge ndert werden kann das dazu f hren dass die Kurve zwischenzeitlich nicht berechnet werden kann Sie erhalten dann bei jeder Berechnung eine Fehlermeldung Mit Grenzen x aktiviert Die Grenzen der nicht linearen Zonen werden bei jeder nderung neu berechnet g deaktiviert Bei einer nderung werden die Grenzen der nicht linearen Zonen beibehalten Optimierte Manuelle Korrektur x aktiviert Gemessene Temperaturen werden ber cksichtigt deaktiviert Gemessene Temperaturen werden nicht ber cksichtigt SHE sartorius 243 seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz 13 6 244 Produkteinstellungen Hier legen Sie den Datensatz f r ein neues Produkt an Hier ndern Sie Parameter f r ein Produkt Das Men hat folgende Men punkte Bearbeiten Details auf Seite 244 Einstellungen Details auf Seite 247 Drucken Details auf Seite 247 Export Details auf Seite 247 Das aktuell gew hlte Produkt ist mit einem gr nen H kchen gekennzeichnet Bearbeiten Die Parameter f r ein Produkt
333. ter a reference value type or remark If you do so the input dialog is displayed Note Values are displayed rounded off in accordance with the settings in Global settings Details on page 108 When making entries enter all decimal places Press Close The input process is complete Remark The Text input Details on page 124 dialog appears Remarks are free text entries Press Apply to add the entry to the table Note This dialog is displayed following every measurement of a calibration value Typically you enter the number of the sample here This allows samples and measured values to be clearly assigned to each other Reference moisture The Numerical input Details on page 125 dialog appears Enter the laboratory value for the moisture ofthe sample with all decimal places The display of the values is rounded off in accord ance with the settings Press Apply to add the entry to the table This dialog is displayed following every measurement of a calibration value Type You can depict individual points on the calibration curve using different symbols This allows you to display measurements made on different days more clearly on the calibration curve for example Press an input field to display the Type dialog Select whether the calibration point is to be used for the calibration Valid The calibration point is valid and is used to calculate the calibration curve x m The value is not taken into account for
334. test gt Graphics gt Settings The floating average values are not in the permitted range see 4x0 The calibration cannot be calculated as there is no product temperature choose Calibration gt Calibration Moisture or Calibration Density gt Type settings Calibration type for the calibration correction process Make sure that the product temperature sensor is connected and working properly 8 0 0 If you activated the Temperature coefficients option in the Sensor modes dialog you must connect a sensor that returns temperature values 9 0 0 The moisture or density values exceed the given range Change the values in the product settings see Product settings Details on page 103 HE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA 14 Shortcuts All functions of the program can be called from the menu For some of the more frequently used functions direct access options or shortcuts are also available to simplify your work with the soft ware The following pages provide an overview of the shortcuts in TMV The menu commands are listed on the left hand side and the right hand side displays the area of the touchscreen that you need to press to execute the relevant function Display of measured values table or graphic Measurement gt Graphic Press the status line r Measurement gt Table T Note This command is used for switching Le quickly from another area e g product se
335. the USB stick Backup on external PC Press Browse and specify the storage location Change the file name if required Observe the naming convention backup_ lua Press Save Restore USB stick only for laboratory devices Attention If you restore a backup all data stored on the device since the backup was saved is lost Before restoring a backup create a current backup file Insert the USB stick containing the backup file into the USB port on the device The backup file must have been created using a device of the same type Inthe Backup dialog select Restore and then press the lower list box Select one of the dis played backup files Press Apply The device state saved in the backup file is restored Wait a moment before you remove the USB stick Restore from external PC Attention If you restore a backup all data stored on the device since the backup was saved is A lost Before restoring a backup create a current backup file In the Backup dialog select Restore and then press the lower list box Select one of the dis played backup files and then press Apply If the required backup file does not appear in the list press Browse and browse to the storage location of the required backup The backup file must have been created using a device of the same type Select the backup file and press Open The device state saved in the backup file is restored HE sartorius seg mechatronics WLM6009 a10
336. the calibration However the entry remains in the table and can be set to Valid at a later time if required ERE sartorius e H mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference B Symbol Press the list field and select a symbol In the calibration graph the calibration point is represented by the selected symbol Press Apply to accept the setting All values The Calibration properties dialog appears Existing information is shown Press an input field The Numerical input Details on page 125 or Text input Details on page 124 dialog appears If you selected the option for entering the type the Type page 86 dialog is displayed Press Apply to accept the setting Delete Individual values can be deleted from the calibration In the menu select Calibration gt Moisture calibration gt Table gt Edit gt Delete The table is now displayed in delete mode i e the controls page 70 for selecting one or more rows are displayed at the bottom Press a row The value is selected Press Delete The selected value is deleted The system continues to take the value into account until the cal ibration curve is recalculated Press Close The deletion process is complete Note Calibration points can be removed from the calibration without being deleted To do so choose Type and set the point s property to Invalid page 86 This value is not taken into account for th
337. the list is defined as the default printer If no default printer is defined the first printer in the list is used as the default printer Printer Options This tab is for making printer specific default settings such as the paper size or print resolution The displayed options depend on the printer model If there are several options you can use the Up and Down buttons to switch between the different displays Press Set Printer Options to save the changed default settings for the printer Settings that were changed but not yet implemented are displayed in red User configuration O Note You need to be logged on with at least level 5 access rights to change these settings A table of users is displayed You can sort the table SHE sartorius 115 seg d mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference ON el 116 You can define a user as the default user If a default user is defined the device automatically starts up with the rights assigned to this user when it is switched on regardless of which user was logged on most recently and without asking the current user to enter a password If a default user is not defined you are always asked to log on after starting the software The default user is indicated by an X If you want to define another user as the default user you have to withdraw this privilege from the current default user first Press a row to select a user Create The dialog
338. the sensor is empty if appropriate The sensor must be free from product residues Select the product REFERENCE 3 Perform an Empty sensor adjust 4 Fill the reference solid into the sensor or place the reference solid on the sensor for planar sen sors Perform the measurement s and compare these with the values stated on the certificate 6 Ifthe values exceed the limits stated on the certificate contact the Sartorius service Ei sartorius e cece 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Other functions 58 HE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA 10 Service and maintenance 10 1 Software update O Note If you are controlling the measuring device using an external PC you must also update the software on the external PC following a software update on the measuring device You receive software updates from Sartorius as zip files 1 Create a new empty folder on your PC and unzip all files from the zip file Make sure that you retain file paths and the folder structure of the files 2 Copy the unzipped files and folders to the USB stick you received with your measuring instru ment Turn off the device using the on off switch at the back 4 Insert the USB stick into one of the USB ports Turn on the unit using the on off switch at the back The update is automatically detected and installed O Note Ifthe device does not seem to react during the startup process rem
339. tronics WLM6009 a10081 LMA316PA LMA321PA Startup 5 3 5 4 5 5 26 Do not use any tools to tighten the connection If you want to detach the cable first complete unscrew the cover from the thread of the device connection Workflow overview Once you have connected the evaluation unit corresponding sensor and any other peripheral devices such as a printer switch the LMA3xxPA PMD3xxPA on The software starts up You then have to prepare the system for measuring a product as follows Creating a product Details on page 30 Calibration Details on page 35 Once you have carried out these steps the device is ready to take measurements Taking measurements Details on page 45 Note Each product to be measured is created once with the corresponding product parameters You normally only have to carry out one basic calibration per product and measurement type moisture density Similar products must be configured separately but can reference a common calibration Starting the LMA321PA Note The following description applies to the LMA316PA as well Turn on the LMA321PA using the on off switch on the rear of the device The software of the LMA321PA microwave measuring system starts up Note It may take a couple of minutes for the software to boot The screen remains black during this time When the user interface appears on the screen the unit is ready to operate If there is a default user the software automat
340. ttings to the measurement area and not for switching between the graphic and the table view The measurement area is displayed using the last selected display type Switching the display between the graphic view table view and value display if applicable Measurement gt Graphic or table Press on the screen area for the operating type Measurement gt Values A A Calibration gt Moisture or Density gt Graphic or table 4 MyProduct J HH LLJ Service gt MWTest gt Compression test gt Graphic or table Calling the Values Settings dialog Measurement gt Values gt Settings Press one of the two display panels You can use this dialog to select which val ues to display in the two fields moisture density temperature no display 7 22 Calling the Product selection dialog Measurement gt Product selection Press the product name Calibration gt Product selection a Service gt MWTest gt Measurement Compression test gt Product selection 2 sartorius 131 coe mechatronics WLM6009 a10081 LMA316PA LMA321PA Shortcuts Settings dialog for the graphic display Measurement gt Graphic gt Settings Press one of the labelled axes Calibration gt Moisture gt Graphic gt Settings Direct entry of the offset for moisture The moisture offset is changed in the product Press the moisture offset display characteristics dialog called by choosing P
341. ttings You can display a larger or smaller view of the chart To call up the dialog for the settings described below click on one of the two axes in the graphical depiction auto 1 Select this box to enable the automatic adjustment of the view x Activated The values for the X and Y axes are automatically adjusted The zoom factor is set to 100 7 Deactivated Enter the values yourself Zoom 2 Enter any value between 1 and 400 X axis Y axis 3 Enter the lowest Min and highest Max value for the display area Activate temperature moisture correction reference lines Activate O Note You can activate temperature or moisture correction x Activated Measurement results are corrected accordingly if fluctuating measurement temperatures are detected 2 Deactivated No temperature correction takes place Increment 1 Enter a temperature correction factor I 2 Click Apply to accept the settings Graphic gt Print The graphical depiction of the calibration can be printed See page 53 for information on how to connect a printer Select Print gt from the Calibration gt Density calibration gt Graphic menu The graph is printed as it appears on the screen EE sartorius seg 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 100 Type settings Type settings Here you define the type of calibration Choose from the following e Simple Expert auto No
342. ttom Press a row to select it Note You can select one or more rows Press the Print button The selected rows are printed out Press Close The printing of the values is complete Table gt Export The table is exported to a csv file and stored on the connected USB stick Press Edit to change the file name Note If you are using the program on your PC the Export dialog appears Specify a storage location on the PC and change the name of the export file if necessary Note Microsoft Excel 2003 The widespread and universal csv export format cannot be properly interpreted for Excel 2003 Rename the csv file as txt and import it into Excel 2003 using the import function EE sartorius a mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference Graph The graph of the calibration is for display purposes only Values cannot be changed If the Correction option is activated you can modify the correction value for the temperature and or moisture using the slide control or by entering numbers L Temp G zoom MW density 303E est 0 372 1 0 368 4 0 364 7 ES 0 360 4 I 0 356 0 352 4 Kn GE T r T T T 17 T e T T 12 50 12 60 12 70 12 80 12 90 13 00 13 10 13 20 13 30 Reference density The graph shows the deviation of the calibration values from the calculated calibration curve PE Individual calibration points are depi
343. tton to define the end of the block You can now edit the selected entries All Selects all rows Press again to deselect all entries Close Ends the currently selected type of editing x The view remains on the screen until another view measurement calibration is selected EE sartorius W seg d mechatronics WLM6009 a10081 CO J CH 72 Navigation LMA316PA LMA321PA Operator Interface Reference These controls assist you with navigation They are available for the table and graph views These controls move the cursor to another position The screen is modified in line with the new cursor position I lt Y VMAA Takes you to the first entry in a table The first entry in a table may be different depending on the current sorting of the table Takes you to the first value of a graph Scrolls back a page 10 entries in the table The cursor is positioned on the first visible row Scrolls back one entry in the table Takes you to a specified entry in the table See section Jump Details on page 124 Scrolls down one entry in the table Scrolls down a page 10 entries in the table The cursor is positioned on the last visible row Takes you to the last row in the table or to the last value in the graph The control remains activated and therefore has a blue background The other navigation controls can no longer be pressed Currently determined values are cont
344. type of printer under Model Press Add Printer lt name gt The network printer is added to the list of printers that are avail able in TMV After pressing OK in the message stating that the printer was added the system displays the Printer Options tab in which you can define the default settings for the printer The possible options depend on the relevant printer driver If not all options can be displayed at once you can use Up and Down to switch to other options The various settings such as paper format or print quality can be specially selected for each print order In Printer Options define which of the standard settings you want If you change the settings press Set Printer Options to implement the changes You can now set up other printers delete printers define a printer as the default printer or edit the default settings see Editing the printer settings on page 56 by choosing Back to return to the Administration tab Press Close to close the Printer Configuration dialog SHE sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Other functions Setting up a directly connected USB printer O Note USB printers can be directly connected up to laboratory measuring devices of types LMA321PA and LMA316PA only Prerequisites You are logged on and own level 4 or 5 access rights The printer is connected to LMA321PA LMA316PA see page 25 and is turned on 1 Select System settings gt
345. tzerkonfiguration dr cken Sie auf Neu 3 Machen Sie im Dialog Benutzer neu folgende Angaben Nutzername Nutzername der im Anmeldedialog eingegeben werden muss e Nachname Vorname Angaben zur leichteren Identifikation des Benutzers in der Benutzer verwaltung Passworteingabe Passwort das der Benutzer im Anmeldedialog eingeben muss das Pass wort wird bei der Eingabe aus Sicherheitsgr nden nur durch Platzhalter dargestellt SHE sartorius 195 cece 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Weitere Funktionen 5 12 2 e e O 196 e Passwortwiederholung Hier muss das Passwort erneut eingegeben werden um Schreib fehler bei der ersten Eingabe auszuschlie en Benutzerebene Hier w hlen Sie aus der Liste die Stufe der Zugriffsrechte aus e Standardbenutzer Falls noch kein Standardbenutzer angelegt ist k nnen Sie hier durch Ak tivieren der Option den neuen Benutzer als Standardbenutzer einstellen Hinweis Wichtige Hinweise zum Standardbenutzer Der Standardbenutzer muss sich beim Starten des Ger ts nicht anmelden Es wird daher dringend empfohlen als Standardbenutzer nur einen Benutzer mit niedrigen Zugriffsrechten Stufe 0 oder 1 auszuw hlen Es kann immer nur ein Benutzer als Standardbenutzer festgelegt sein Das Festlegen eines Standardbenutzers ist nicht zwingend notwendig Wird kein Standardbe nutzer definiert muss sich jeder Benutzer gleich welcher Zugriffsstufe nach dem Ger testart anm
346. ue This applies to all empty measurements including those that are carried out automatically during a laboratory or process measurement sequence Meas trigger input no On line device Optionally you can hide the average values from the meas ured values with a 24 V digital input Defines the type of process measuring device Time for float mean sec Measurement interval sec Moving average values for moisture density temperature etc are calculated and periodically stored for all running measurements using the time defined here The interval for saving the data is defined in Measurement interval Time for probe sec Maximum emptying time sec Time period for which all measured values are determined and copied to the calibration after the Sampling button has been pressed Available time period before the empty measurement for removing the product inserting an empty measuring beaker after the appearance of the Please empty message Maximum filling time sec Available time period before the measurement for filling the sensor after the appearance of the Please fill message Maximum measurement time sec Temperature measurement pause sec Available time period for saving the measurement results after the measurement Time span for inserting temperature sensor Pt 100 into the sample If using IR sensors no pause is required i e the value can be set to No Wait for stable tempe
347. uf die Schaltfl che Drucken Ch Die entsprechenden Tabellen zeien werden ausgedruckt 3 Dr cken Sie auf Schlie en Das Drucken der Werte ist beendet x SHE sartorius 229 cece mechatronics WLM6009 a10081 Fa O O Ze O 2 1 e g 230 LMA316PA LMA321PA Bedienoberfl che Referenz Tabelle gt Export Die Tabelle wird im Format csv exportiert und auf dem angeschlossenen USB Stick gespeichert Dr cken Sie auf Bearbeiten um den Dateinamen zu ndern Hinweis Wenn Sie das Programm am PC nutzen erhalten Sie den Dialog Export Hier w hlen Sie einen Speicherort auf dem PC und hier ndern Sie gegebenenfalls den Namen der Exportdatei Hinweis Microsoft Excel 2003 Das weit verbreitete universelle Exportformat csv ist f r Excel 2003 nicht richtig zu interpretieren Benennen Sie die csv Datei in txt um und importieren Sie sie in Excel 2003 mit der Importfunktion Grafik Die Grafik der Kalibration dient nur zur Anzeige Werte k nnen hier nicht ver ndert werden Bei aktivierter Option Korrektur kann die Korrektur f r Temperatur und oder Dichte mittels Schie beregler oder Zahleneingabe angepasst werden MW Feuchte Temp 0 372 0 368 0 364 1 BESCH 0 360 1 0 356 1 0 352 1 8 g 0 348 1 1 12 70 13 10 13 20 13 30 Referenzfeuchte 12 50 12 60 12 30 12 90 13 00 Die Grafik verdeutlicht die Abweichung der Kalibrationswerte
348. up berschrieben wird Der Dateiname kann falls gew nscht aber auch ge ndert werden Achtung Falls Sie den Dateinamen des Backups ndern m chten beachten Sie unbedingt die Schreibkonventionen Backup_ lua Anderenfalls kann das Backup anschlie end nicht wieder hergestellt werden Dr cken Sie Speichern Das Backup wird jetzt auf den PC gespeichert der Backup Dialog auto matisch geschlossen Wiederherstellen Mit dieser Funktion kann das System komplett auf den Zustand eines zuvor erstellten Backups zur ckgesetzt werden Vorsicht Beim Wiederherstellen gehen alle Messungen Eingaben usw die nach dem einge spielten Backup gemacht wurden verloren Erstellen Sie ggf zur Sicherheit ein Backup des ak tuellen Zustands bevor Sie die Funktion Wiederherstellen ausf hren HE sartorius seg mechatronics WLM6009 a10081 LMA316PA LMA321PA Wartung und Pflege 2 O 5 Durchsuchen 1 2 3 4 Voraussetzungen Das Messger t ist eingeschaltet und Sie sind mit Zugriffsrechten der Stufe 4 oder h her angemeldet siehe Backup erstellen Stoppen Sie ggf laufende Messungen Stecken Sie den USB Stick auf dem sich die Backup Dateien befinden in den USB Anschluss auf der Vorderseite entf llt beim Wiederherstellen von einem externen PC Hinweis Es kann einige Sekunden dauern bis der USB Stick erkannt wird und zur Verf gung steht W hlen Sie Service gt Backup Es ffnet sich der Dialog Backup W
349. us 123 e H mechatronics WLM6009 a10081 LMA316PA LMA321PA Operator Interface Reference 225 Apply Cancel 1 Choose whether you want the display to go to a position or to the value of a specific time To do so press the list box Once the list box has expanded press Pos or Time Further input fields either for the position number or date and time are displayed depending on your selection 2 Press one of the numerical input fields The Numerical input Details on page 125 dialog appears 3 Enter the required value and press Apply in the dialog for entering number The value is only accepted if there are entries for the selected position or date 4 After making your selection press Apply in the Jump dialog The table now displays the corresponding entry In the graphical depiction the cursor jumps to the corresponding entry The values of the selected entry are displayed in the panels Text input This dialog is displayed when you need to enter text O Note If the virtual keyboard is deactivated in System settings gt Global settings gt Settings 2 only an input field is displayed You can enter text using a USB keyboard or the keyboard of an external PC 1 T VE O EN cee sO eA Y OR TOR SON OR ee IE I cn dad Bud D a s d f g h j k l i t z x c v b n m j 2 Lee ech X EE Controls for entries which are not relevant or not allowe
350. utzer keine Rechte hat bleiben f r diesen Benutzer unsichtbar Einzelne Werte in Dialogen sind f r manche Benutzer ggf nicht editierbar hier werden jedoch die eingestellten Werte zur Information ange zeigt Standardbenutzer Aktivieren Sie diese Option falls der Benutzer als Standardbenutzer festgelegt werden soll Dies ist nur m glich wenn kein anderer Standardbenutzer festgelegt ist Gegebenenfalls m ssen Sie zuvor beim bisherigen Standardbenutzer diese Option deaktivieren Reset i Alle Eintr ge im Eingabedialog werden gel scht bernehmen S Alle vorgenommenen Anderungen werden gespeichert SHE sartorius 259 cece 3 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz 260 Makroeinstellung Hinweis F r diese Einstellungen m ssen Sie mit Zugriffsrechten mindestens der Stufe 4 angemeldet sein In diesem Bereich k nnen f r verschiedene Grundfunktionen die Einstellungen ge ndert und z T auch deaktiviert werden Die zur Verf gung stehenden Einstellungen unterscheiden sich abh ngig von der Ger teart W hlen Sie den Men befehl Systemeinstellungen gt Makroeinstell Die installierten Makros werden in einer Tabelle aufgelistet mit Bezeichnung Wert und Status der Verf gbarkeit Beispielabbildung om TM oles Feuchte 0 75 24 3 C 44 Hilfe Chronik Makro settings Version 2848 Name Value Available 1 2 Data over
351. ve sensor mains and Ethernet crossover cables required for the connection Pt 100 temperature sensor Keyboard Additional item for LMA321PA Pen for operating the touch screen Optional components the TMV software on CD IR temperature sensor Multiplexer for connection of a further sensor integrated Note The evaluation unit may be delivered without sensor if there is already a sensor available The further scope of delivery is dependent on the range of applications For information on this please refer to the order documentation HE sartorius seg x mechatronics WLM6009 a10081 LMA316PA LMA321PA 4 Control via external PC The microwave measuring devices in the PMD320PA PMD325PA and LMA316PA LMA321PA series may alternatively be controlled via an external Windows PC To enable this control the TMV software is installed TMV can be used to export data to an external PC as well as for storing backup copies to this PC for example There are two options for connecting the measuring device or evaluation device to the PC Direct connection of the PC to the measuring device via crossover network cable Inclusion of the measuring device in an existing network via TCP IP Adding the measuring device to a network has the additional advantages as follows e Evaluation unit and control computer may be distant from each other e g production hall office One PC can control several measuring devices 4 1 Overvie
352. vers or other sharp edged objects Place the LMA316PA LMA321PA on a stable level and heat resistant surface The top surface of the LMA316PA LMA321PA can be used to position a monitor for example for measuring devices that do not have an integrated touchscreen Max load 5 kg Do not place any other objects on the LMA316PA LMA321PA EE sartorius a eegg mechatronics WLM6009 a10081 LMA316PA LMA321PA Safety instructions Disconnect the measuring device from other units before moving it to another place or trans porting it Pull out the plug from the rear of the device The feet ofthe device are found on the underside As the furniture or floor base surfaces consist of various materials and are treated with various cleaning substances it cannot be completely ruled out that these substances may contain components that attack the instrument s feet and soften them If necessary place a non slip pad under the feet of the instrument Safety relevant signs on the devices The nameplate on the underside of the device contains the following warning WARNING DISCONNECT SUPPLY BEFORE SERVICING eee Ce Before installation deinstallation service work or cleaning with liquids disconnect the device from the power supply by removing the mains plug Please refer to the corresponding safety infor mation and work instructions in the manual The following warning sign is attached to the planar sensors Caution R
353. vices with the same name must always be connected to each other For easier assignment both the MW Gen connections and the microwave cable used for this con nection are marked in green Sensor 1 2 Optional linkage to the sensor for devices of the Black Line series The sensors transfer the configuration data as well as any temperature measurement data over this interface Temperature sensor thermometer symbol It is possible to connect an additional PT 100 temperature sensor for determining the current temperature values The PT 100 can either be used as an alternative to atemperature sensor integrated in the sensor or for sensors that do not possess a built in temperature sensor Ethernet network symbol The evaluation can be linked to the company network by means of a network cable In this way the evaluation device can be controlled using an external PC with a Windows version of the soft ware Note The network settings IP address etc are specified in System settings gt Configuration gt Communication gt This TMV access dependent on the respective user rights Operating procedures directly on the evaluation device take priority over commands entered via the Windows version on the external PC Service interface spanner symbol RS232 interface for service purposes only Connection to service laptop in cases of malfunction COM Passive message interface Monitor If an external monitor is used then it is to
354. voll oder gestattet sind bleiben inaktiv SHE sartorius 267 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz 268 Die Schaltflache Ubernehmen kann erst gedriickt werden wenn eine Eingabe gemacht wurde Bei Arbeit mit einer Tastatur k nnen Zeichen auch ber die Tastatur eingegeben werden a L schtaste We Das Zeichen vor der Schreibmarke wird gel scht Hinweis Die Schreibmarke im Eingabefeld wird am Touchscreen durch Fingerdruck an der entsprechenden Stelle neu positioniert Bei Arbeit mit der Tastatur kann die Schreibmarke mithilfe der Pfeiltasten versetzt werden Umschalttaste amp Schaltet die Tastatur um zur Eingabe von Kleinbuchstaben und Zahlen Feststelltaste Schaltet die Tastatur um zur Eingabe von Gro buchstaben und Sonderzeichen Bei wiederholtem Dr cken schaltet diese Schaltfl che zur ck zur Eingabe f r Kleinbuchstaben Gel Zahleneingabe Dieser Dialog wird dann angezeigt wenn Zahlen numerische Werte eingegeben werden sollen Hinweis Ist in den Systemeinstellungen gt Globale Einstellungen gt Einstellungen 2 die Virtuelle Tastatur deaktiviert erscheint lediglich ein Eingabefeld in das die Werte direkt ber eine USB Tastatur bzw die Tastatur des externen PCs eingegeben werden 24 8 7 8 9 4 5 6 Entf 1 2 3 EE d 2 a Abbruch Schaltfl chen f r Eingaben die im jeweiligen Zusammenhang nicht sinnvoll
355. von der errechneten Kalibrations kurve Einzelne Kalibrationspunkte werden entsprechend der Einstellung f r Typ Seite 227 mit unterschiedlichen Symbolen dargestellt Kalibrationspunkte die nicht zur Berechnung der Kurve verwendet werden sind gr n dargestellt Hinweis W hrend die Grafik angezeigt wird k nnen Messungen zur Kalibration durchgef hrt werden Die Eingabedialoge zur Bemerkung und zum Referenzwert erscheinen automatisch Dr cken Sie auf die Betriebsartanzeige Kalibration Feuchte oder das Grafik Symbol um zur Tabellenansicht umzuschalten Zoom Geben Sie einen Wert im Feld Zoom ein oder klicken Sie auf die Felder mit den Pfeilen um die Grafik vergr ert bzw verkleinert anzuzeigen Klicken Sie auf die Schaltfl chen Vergr ern bzw Verkleinern um den Zoomfaktor um schritt weise 5 zu ver ndern sartorius mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberfl che Referenz 3 Wenn Sie die Grafik vergr ert anzeigen verschieben Sie die Grafik indem Sie auf die Grafik dr cken und diese verschieben bzw am PC klicken Sie in die Grafik und verschieben die Grafik mit der Maus bei gedr ckter Maustaste 4 Falls aufgrund der Einstellungen keine Grafik dargestellt wird w hlen Sie unter Grafik gt Einstel lungen die Option auto Temp Temperaturkorrektur Wenn f r die Kalibration eine Temperaturkorrektur gew hlt ist Seite 233 erscheint ber der Grafik ein Schieberegler und ein Ei
356. w Proceed as follows to implement control via external PC 1 Install TMV on the PC 2 Connect the network cable connection either via crossover cable between PC and measuring device or measuring device to the existing network 3 Create an entry with the IP address of the measuring device and activate the connection 4 2 Installing TMV The program is designed to run on computer using the Microsoft Windows 2000 XP Vista operating systems Prerequisites Exit any applications that may still be running and turn off any virus scanners while installing 1 Insert the TMV CD in your PC s CD or DVD drive 2 Check the CD for TMV_ lt version number gt _Setup exe e g using Windows Explorer and dou ble click on the executable to run the installer OT Setup IUS Welcome to the TMY Setup Wizard Before beginning the installation of TMY Lite please choose a language Click Next to continue sartor 3 On the installer s splash screen open the list under Language pick a language and click on Next EE sartorius a Ha mechatronics WLM6009 a10081 LMA316PA LMA321PA Control via external PC 18 Note The language of the splash screen depends on the language set for your operating system All other installer dialogs will be in the language chosen on the splash screen TMV then also starts using this language You can however change the software language at any time Cli
357. weder Feuchte Kalibration oder Dichte Kalibration F r eine bersichtliche Darstellung der Kalibrationsmesswerte empfehlen wir die Darstellungs form Tabelle Standardeinstellung Wechseln Sie ggf ber den Men punkt Tabelle zu tabella rischen Darstellung O Hinweis Falls f r das gew hlte Produkt bereits Kalibrationsdaten vorhanden sind dann werden diese jetzt angezeigt 7 Dr cken Sie auf Start 8 Falls sich noch ein Produkt im Sensor befindet erhalten Sie die Meldung Bitte leeren In diesem Fall entnehmen Sie das Produkt bzw setzen Sie einen leeren Messbecher ein je nach Sensor Sie sehen die Meldung Leerabgleich Das Ger t meldet dass es den Sensor als leer erkannt hat O Hinweis Falls Sie aufgefordert werden den Sensor zu leeren obwohl dieser leer ist dann dr cken Sie auf die Schaltfl che Leerabgleich Dem Sensor wird so mitgeteilt dass er leer ist eventuelle Ver nderungen am Sensor z B Verschmutzung oder thermische nderungen werden auf diese Weise kompensiert 9 Sie erhalten die Meldung Bitte f llen Bef llen Sie den Sensor Falls Sie einen Sensor mit Messbecher nutzen achten Sie darauf dass der Messbecher kom plett gef llt ist Vermeiden Sie bei der Bef llung des Messbechers das Entstehen gr erer Hohl r ume Falls Sie einen Planarsensor nutzen achten Sie darauf dass der Sensor gleichm ig mit dem Produkt bedeckt ist 10 Optional F hren Sie den Temperatursensor Pt 100
358. werkdrucker nicht automatisch angezeigt wird und Hostname oder IP Adresse des Druckers manuell eingegeben werden m ssen W hlen Sie im Register Make Model Driver zun chst unter Make den Druckerhersteller und anschlie end unter Model den Typ des Druckers aus Dr cken Sie auf Add Printer lt Name gt Der Netzwerk Drucker wird der Liste der in TMV ver f gbaren Drucker hinzugef gt Nach Dr cken auf OK in der Meldung dass der Drucker angelegt wurde erscheint das Register Printer Options in dem Sie die Voreinstellungen f r den Drucker festlegen k nnen Die m gli chen Optionen sind abh ngig vom jeweiligen Druckertreiber Falls nicht alle Optionen auf einmal dargestellt werden k nnen k nnen Sie ber die Schaltfl chen Up und Down zu den weiteren Optionen wechseln Die verschiedenen Einstellungen wie Papierformat oder Druckqualit t k nnen bei jedem Druck auftrag gesondert ausgew hlt werden Hier in den Printer Options legen Sie lediglich fest welches die Standardeinstellungen sein sollen Falls Sie Einstellungen ge ndert haben dr cken Sie auf Set Printer Options um die nderun gen zu bernehmen Sie k nnen jetzt noch weitere Drucker anlegen Drucker l schen als Standarddrucker definieren oder die Voreinstellungen bearbeiten siehe Bearbeiten der Druckereinstellungen auf Seite 201 indem Sie auf Back dr cken um zum Register Administration zur ckzukehren Dr cken Sie abschlie end auf Close um den Dial
359. wieder auf g ltig gesetzt werden nii sartorius 227 mechatronics WLM6009 a10081 LMA316PA LMA321PA Bedienoberflache Referenz 228 Symbol Drucken Sie auf das Listenfeld und wahlen Sie eines der Symbole aus Der Kalibrationspunkt wird in der Grafik der Kalibration durch das gewahlte Symbol dargestellt Dr cken Sie auf bernehmen um die Einstellung zu bernehmen Alle Werte Sie erhalten den Dialog Kalibrationseigenschaften Bereits bestehende Angaben werden angezeigt Dr cken Sie auf ein Eingabefeld Sie erhalten entsprechenden Dialog zur Zahleneingabe Details auf Seite 268 bzw zur Texteingabe Details auf Seite 267 Falls Sie die Eingabe f r Typ gew hlt haben erhalten Sie den Dialog Typ 2 Seite 227 Dr cken Sie auf bernehmen um die Einstellung zu bernehmen L schen Einzelne Werte k nnen aus der Kalibration gel scht werden W hlen Sie im Men Kalibration gt Feuchte Kalibration gt Tabelle gt Bearbeiten gt L schen Die Tabelle wird nun im Modus zum L schen angezeigt das hei t am unteren Rand sehen Sie die Schaltfl chen gt Seite 210 zum Markieren einer oder mehrerer Zeilen Dr cken Sie auf eine Zeile Der Wert ist markiert Dr cken Sie auf L schen Der markierte Wert wird gel scht Der Wert wird weiter ber cksichtigt solange bis die Kalibrati onskurve neu berechnet wird Dr cken Sie auf Schlie en Der L sch Modus ist beendet Hinweis Sie k nnen einzelne Kalibrat
360. word input Password to be entered when logging on for security reasons placehold ers can be seen only when you enter the password Password repeat Enter the password again to exclude typing errors in the first entry User level Pick a level from the dropdown list Default user If no user has been previously defined as the default user tick the box next to this entry to set the user you are creating as the default user Note Important information about the default user The default user does not need to log on when they start the unit We therefore strictly recommend to only define a low level user level 0 or 1 as the default user You can only have one default user at a time A default user is not really a must If no default user is defined every user regardless of their access level must log on after starting the unit Click on Apply when all parameters are set The new user will be added to the list Select the User configuration and click on Apply as well Notes on editing the user profile To change the settings of a user record e g to assign a new password display the User confi guration page select the appropriate entry and press Edit The Edit user dialog will pop up showing the settings of the selected user Edit the entries as you would do when creating a new user record To remove a user from the list select the appropriate entry and press Delete After confirming the security prompt the user rec
361. z Temp Cem gt Zoom 30 38 100 0 372 1 u 368 J slit d MW Dichte 364 na 352 1 1 m 1 JE EEE EUER EHEN DEE oOo o o o oO CO w CH 348 4 I a EEE E 12 50 12 60 12 70 1280 1290 13 00 13 10 13 20 13 30 Referenzdichte Die Grafik verdeutlicht die Abweichung der Kalibrationswerte von der errechneten Kalibrati onskurve Einzelne Kalibrationspunkte werden entsprechend der Einstellung f r Typ gt Seite 227 mit unterschiedlichen Symbolen dargestellt Kalibrationspunkte die nicht zur Berechnung der Kurve verwendet werden sind grau dargestellt O Hinweis W hrend die Grafik angezeigt wird k nnen Messungen zur Kalibration durchgef hrt werden Die Eingabedialoge zur Bemerkung und zum Referenzwert erscheinen automatisch ee 2 Dr cken Sie auf die Betriebsartanzeige Kalibration Feuchte oder das Grafik Symbol um zur Tabellenansicht umzuschalten Zoom 1 Geben Sie einen Wert im Feld Zoom ein oder klicken Sie auf die Felder mit den Pfeilen um die Grafik vergr ert bzw verkleinert anzuzeigen 2 Klicken Sie auf die Schaltfl chen Vergr ern bzw Verkleinern um den Zoomfaktor um schritt weise 5 zu ver ndern 3 Wenn Sie die Grafik vergr ert anzeigen klicken Sie in die Grafik und verschieben die Grafik mit Q der Maus bei gedr ckter Maustaste 4 Falls aufgrund der Einstellungen keine Grafik dargestellt wird w hlen S

Download Pdf Manuals

image

Related Search

Related Contents

Human Machine Interface BACnet/IP - Slave  SYBA SY-AUD23018 loudspeaker  基板表面実装形で ラバープランジャによりシール構造・ 好感触・ミドル  T'nB CSPOP headphone  SD394SPIEVK - Evaluation Board for LMH0394    Descarga PDF  

Copyright © All rights reserved.
Failed to retrieve file