CPH 6200 CPH 6200-D CPH 6200-Ex

image

Contents

1. mean TC of zero signal 0 2 10K mean TC of span 0 2 10 K Connection to CPH 6200 via 1 m cable plug amp play on request up to 5 m Weight approx 220g 2 O ring made of Viton or EPDM for flush diaphragm with integrated cooling element 3 The oxygen version mus not be used with medium temperatures higher than 60 C Cannot be manufactured for absolute pressure ranges lt 1 bar abs Items in curved brackets are optional extras at an additional price 11 Accessories For Accessories such as Pressure pumps pneumatic hydraulic flexible pressure hose pressure adapters Data logger evaluation software Gsoft or calibration software power supply unit battery charger rechargeable batteries etc see current WIKA Testing and Calibration Technology pricelist WIKA Operating Instructions Hand Held Pressure Indicator 25 Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex Information Dieses Zeichen gibt Ihnen Informationen Hinweise oder Tipps Warnung Dieses Symbol warnt Sie vor Handlungen die Sch den an Personen oder am Ger t verursachen k nnen 26 WIKA Betriebsanleitung Hand Held Druckmessger t 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex ala re Bg nS S u 1 Allgemeines 1 1 Allgemeine Sicherheitshinweise 1 2 Betriebs und Wartungshinweise 1 3 Anschl sse 1 4 Anzeige 1 5 Bedienung 2
2. Netzger t berpr fen austauschen Systemfehler Batterie und Netzger t abklemmen kurz warten wieder anstecken Ger t defekt Zur Reparatur einschicken Err 1 Messbereich ist berschritten Pr fen liegt Druck ber zul Messbereich des Sensors gt Messwert ist zu hoch Sensor defekt Zur Reparatur einschicken Err 2 Messbereich ist unterschritten Pr fen liegt Druck unter zul Messbereich des Sensors gt Messwert ist zu hoch Sensor defekt Zur Reparatur einschicken Err 4 Wert ist zu niedrig f r Anzeige Tara aktiv Pr fen Anzeige unter 2000 tara Err 7 Systemfehler Zur Reparatur einschicken Err 9 Angesteckter Sensor oder Ger t ist defekt Mit evtl vorhandenem 2 Sensor das Ger t berpr fen Defekten Sensor bzw defektes Ger t zur Reparatur einschicken Messbereich ist weit unter oder berschritten Pr fen liegt Druck innerhalb Messbereich WIKA Betriebsanleitung Hand Held Druckmessger t 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex 8 Sicherheitshinweis zum Ex Betrieb Zus tzliche Ex Betriebshinweise Ex D Erg nzend zu den Allg Sicherheitshinweisen unter 1 1 E Batteriebetrieb Es d rfen nur 9 V Batterien des Typ IEC 6F22 in Zink Kohle Technologie verwendet werden Der Batterietausch darf nur au erhalb des explosions
3. WIKA is a registered trade mark of WIKA Alexander Wiegand GmbH amp Co KG Names of companies or products mentioned in this handbook are registered trade marks of the manufacturer We reserve the right to effect reasonable changes on the basis of technical improvements Any reproduction of this manual or parts thereof by any means is prohibited Version key regarding firmware and respective manual V4 0 4 9 2005 Copyright WIKA Alexander Wiegand GmbH amp Co KG WIKA Operating Instructions Hand Held Pressure Indicator 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex 1 1 General safety instructions GB This device has been designed and tested in accordance with the relevant safety regulations for electronic devices However its trouble free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advise given in this manual is followed when using the device 1 Trouble free operation and reliability of the device can only be guaran teed so long as the device is not subjected to any climatic conditions other than those stated under Specification 2 The device and sensors must be handled with care don t throw hit etc Protect plugs and sockets from contamination 3 If the device is moved from a cold to a warm environment condensation may cause the equipment to fail You should therefore e
4. requirements established in the regulations of the council for the Approximation of Legislation of the member countries regarding electromagnetic compatibility 89 336 EWG 1 For the Intrinsically Safe Version the use of the interface is not permitted within an explosive atmosphere Calibrated in vertical mounting position with lower pressure connection Not available for the Intrinsically Safe Version CPH 6200 Ex Items in curved brackets are optional extras at an additional price 24 WIKA Operating Instructions Hand Held Pressure Indicator 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex CPT 6200 Pressure Transmitter specific details Pressure connection Material wetted parts Internal transmission fluid G B flush diaphragm G1 for 0 1 up to 1 6 bar or various connection adapters on request Wetted parts stainless steel case stainless steel flush diaphragm version stainless steel Hastelloy C4 O Ring NBR Viton or EPDM Synthetic oil only for pressure ranges up to 16 bar or flush diaphragm Halocarbon oil for oxygen applications Listed by FDA for food industry One year stability 0 2 of span at reference conditions Permissible medium temperature 25 100 C ambient temperature 0 50 C storage temperature 40 80 C Compensated range 0 70 C Temperature coefficients
5. CPH 6200 CPH 6200 D CPH 6200 Ex 46 Pr f und Zertifizierungsstelle ZELM x EG Baumusterpr fbescheinigung Ger te und Schutzsysteme zur bestimmungsgem en Verwendung in explosionsgef hrdeten Bereichen Richtlinie 94 9 EG EG Baumusterpr fbescheinigungsnummer ZELM 03 ATEX 0159 X Ger t Hand Held Druckmessger t Typ CPH 6200 ex und zugeh rigem Drucktransmitter Hersteller WIKA Alexander Wiegand GmbH amp Co KG Anschrift D 63911 Klingenberg De Bauart dieses Ger tes sowie die verschiedenen zul ssigen Ausf hrungen sind in der Anla ge zu dieser Baumusterpr fbescheinigung festgelegt De Pr f und Zertifizierungsstelle ZELM Ex bescheinigt als benannte Stelle Nr 0820 nach Artikel 9 der Richtlinie des Rates der Europ ischen Gemeinschaften vom 23 M rz 1994 S4 9 EG die Erf llung der grundlegenden Sicherheits und Gesundheitsanforderungen f r die Konzeption und den Bau von Ger ten und Schutzsystemen zur bestimmungsgem en Ver wendung in explosionsgef hrdeten Bereichen gem Anhang II der Richtlinie De Ergebnisse der Pr fung sind in dem vertraulichen Pr fbericht Nr ZELM Ex 0590315211 festgelegt De grundlegenden Sicherheits und Gesundheitsanforderungen werden erf llt durch berein stimmung mit EN 50 014 1997 A1 A2 EN 50020 1994 Falls das Zeichen X hinter der Bescheinigungsnummer steht wird auf besondere Bedingun gen f r die sichere Anwendung des Ger tes in der Anlage zu dieser Bescheini
6. Phone 27 11 621 00 00 Fax 27 11 621 00 59 E mail sales wika co za www wika co za United Arab Emirates WIKA Middle East FZE Jebel Ali Dubai Phone 971 4 883 90 90 Fax 971 4 883 91 98 E mail wikame emirates net ae Asia China WIKA International Trading Shanghai Co Ltd 200001 Shanghai Phone 86 21 53 85 25 72 Fax 86 21 53 85 25 75 E mail wikash online sh cn WIKA Instrumentation Suzhou Co Ltd 215011 Suzhou Phone 86 512 68 25 98 41 Fax 86 512 68 25 44 62 E mail wikainst public1 sz js cn India WIKA Instruments India Pvt Ltd Village Kesnand Wagholi Pune 412 207 Phone 91 20 27 05 29 01 Fax 91 20 27 05 19 25 E mail sales wika co in www wika co in Japan WIKA Japan K K Tokyo 105 0023 Phone 81 3 54 39 66 73 Fax 81 3 54 39 66 74 E mail t shimane wika co jp Kazakhstan TOO WIKA Kazakhstan 050050 Almaty Phone 7 32 72 33 08 48 Fax 7 32 72 78 99 05 E mail wika kazakhstan nursat kz Korea WIKA Korea Ltd Seoul 153 023 Phone 82 2 8 69 05 05 Fax 82 2 869 05 25 E mail info wika co kr Malaysia WIKA Instrumentation M Sdn Bhd Selangor Darul Ehsan Phone 60 3 56 36 88 58 Fax 60 3 56 36 90 72 E mail info wika com my www wika com my WIKA Betriebsanleitung Hand Held Druckmessgerat Singapore WIKA Instrumentation Pte Ltd 569625 Singapore Phone 65 68 44 55 06 Fax
7. key is pressed for 2 seconds the option to clear the logger memory will be displayed clear all data points clear nothing cancel menu clear the last data point Use the Min or the Max key to display the required option The Store Quit key selects that choice If the logger memory is full the display will show Full Viewing Recorded Measurements Within the LoGG Stor function the measurements can be viewed directly on the instrument display as well as through a computer Func CYCL only allows for the data to be viewed on computer Press the Set Menw key for 2 seconds The first menu displayed is now rEAd LoGG read logger data By then pressing the Tara key the last measurement recorded will be displayed pressing the Tara key again scrolls between the different values related to this data point Pressing the Min key or Max key selects different data points WIKA Operating Instructions Hand Held Pressure Indicator 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex 4 2 Func CYCL Automatic Datalogging with adjustable cycle time GB The Logger Cycle Time is adjustable see Configuration For example setting CYCL 60 A measurement is made every 60 seconds When the slow measurement rAtE Slo is chosen additionally a low power function is available Lo Po If Lo Po is on the device o
8. und die Messfunktion langsame Messung rAtE Slo gew hlt so bezieht sich der Min Max Wertspeicher auf die gemittelten Anzeigewerte Ist die Mittelwertbildung aktiviert und eine schnelle Messfunktion rAtE FASt oder P dEt gew hlt so bezieht sich der Min Max Wertspeicher auf die intern gemessenen Werte gt 100 Hz Messfrequenz 2 5 P oFF Abschaltverz gerung Wird f r die Dauer der Abschaltverz gerung keine Taste gedr ckt bzw keine Schnittstellenkommunikation vorgenommen so schaltet sich das Ger t automatisch ab Die Abschaltverz gerung ist zwischen 1 und 120 min w hlbar Ist RoFF oFF so ist die Abschaltverz gerung deaktiviert 2 6 Adr Schnittstellen Adresse In Vorbereitung f r Multiplexerbetrieb 2 7 AL Alarm Es sind 3 Einstellungen m glich aus AL oFF an mit Hupe AL on an ohne Hupe AL no So Bei folgenden Bedingungen wird bei aktiver Alarmfunktion on oder no So ein Alarm ausgegeben m Untere AL Lo bzw obere Alarmgrenze AL Hi unter bzw berschritten m Sensorfehler Sens Erro m Schwache Batterie bAt m Fe 7 Systemfehler wird immer mit Hupe gemeldet Im Alarmfall blinkt die Anzeige bei Schnittstellenzugriffen wird das PRIO Flag gesetzt 2 8 CLOC Echtzeituhr Die Echtzeituhr wird f r die zeitliche Zuordnung der Loggerdaten ben tigt Kontrollieren Sie deshalb bei Bedarf die Einstellungen Nach einem Batteriewechsel wird nach dem Einschalten des Ger tes automat
9. www wika com mx USA WIKA Instrument Corporation Lawrenceville GA 30043 Phone 1 770 513 82 00 Fax 1 770 338 51 18 E mail info wika com www wika com WIKAl WIKA Alexander Wiegand GmbH amp Co KG Alexander Wiegand StraBe 30 63911 Klingenberg Germany Phone 49 93 72 132 9986 Fax 49 93 72 132 217 E Mail testequip wika de www wika de WIKA Betriebsanleitung Hand Held Druckmessger t 2386816 1 2 08 2005 GB D
10. 65 68 44 55 07 E mail info wika com sg www wika com sg Taiwan WIKA Instrumentation Taiwan Ltd Pinjen Taoyuan Phone 886 034 20 60 52 Fax 886 034 90 00 80 E mail info wika com tw www wika com tw Australia Australia WIKA Australia Pty Ltd Rydalmere NSW 2116 Phone 61 2 88 45 52 22 Fax 61 2 96 84 47 67 E mail sales wika com au www wika com au WIKA Australia Pty Ltd Burwood East VIC 3151 Phone 61 3 88 47 20 00 Fax 61 3 98 02 95 59 E mail sales wika com au 51 WIKA Global Europe Austria WIKA Messger tevertrieb Ursula Wiegand Ges m b H amp Co KG 1235 Wien Phone 43 1 86 91 631 Fax 43 1 86 91 634 E mail info wika at www wika at Benelux WIKA Benelux 6101 WX Echt Phone 31 475 535 500 Fax 31 475 535 446 E mail info wika nl www wika nl Bulgaria WIKA Bulgaria EOOD Blvd Al Stamboliyski Nr 205 1309 Sofia Phone 359 2 82138 10 Fax 359 2 82138 13 E Mail t antonov wika bg Finland WIKA Finland Oy 00210 Helsinki Phone 358 9 682 49 20 Fax 358 9 682 49 270 E mail info wika fi www wika fi France WIKA Instruments s a r l 95610 Eragny sur Oise Phone 33 1 34 30 84 84 Fax 33 1 34 30 84 94 E mail info wika fr www wika fr Italy WIKA Italiana S r l 20017 Rho Milano Phone 39 02 93 97 001 Fax 39 02 93 97 00 70 E mail info wika it www wika it Poland Kujawska Fabryka Manometrow KFM
11. Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex Men f hrung des Hauptmen s Bbbb wm OOF 77 FO TE Speicherdaten Aufruf der gespeicherten Einzelwert logger Daten Siehe Kapitel 4 Konfiguration Einheit Sea Level Messrate Power off Schnittstellen Adresse Alarm Min Max Alarm visuell mit ohne Hupe Logger Umschalten von Hold auf Logger Fkt Einzelwert Stor bzw zyklisch CYCL System Uhr Uhrzeit Tag amp Monat Jahr eee Parameter Nachster Ubernahme einstellen Parameter amp Abbruch ring shift erscheint nur wenn Daten im Einzelwert Logger gespeichert sind erscheint nur wenn keine Daten im Logger gespeichert sind siehe Kapitel 4 xx 34 WIKA Betriebsanleitung Hand Held Druckmessger t 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex Men Param Werte Bedeutung Menu gt A odery SEt Set Configuration Allgemeine Einstellungen ConF Unit mbar bar Unit Anzeigeeinheit SL oFF on Sea Level Meeresh hen Korrektur an aus Alti 200 9999 Altitude Meeresh hen Korrektur in m x nur wenn SL an rAtE Rate Messgeschwindigkeit Siehe 2 3 a Slo Slow langsame Messung 4 Hz gefiltert geringer Stromverbrauch FASt Fast sch
12. blich sollten sie in regelm igen Abst nden ca 1x j hrlich auf Einhaltung der Spezifikationen berpr ft werden siehe Punkt 9 1 3 Anschl sse Am oberen Ende des Ger tes befindet sich die Anschlussbuchse CH1 und CH2 CH2 nur bei 2 Kanal Ausf hrung zum Anschluss der Drucksensoren der CPH Serie siehe Kapitel 6 und die Buchse zum Anschluss des Schnittstellenconverters siehe Kapitel 5 Anschluss f r Schnitt Stellenconverter CH1 CH2 nur bei 2 Kanal Ausf hrung CPH 6200 D An der linken Seite des Ger tes befindet sich die Netzbuchse zum Anschluss des erh ltlichen Netzger tes siehe aktuelle Preisliste CPH 6200 WIKA Betriebsanleitung Hand Held Druckmessger t 31 Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex 1 4 Anzeige BBB l A888 Hauptanzeige zeigt den aktuellen Messwert an A signalisiert schwache Batterie und andere Warnungen 3 Nebenanzeige zeigt bei 2 Kanal Ausf hrung den Messwert von CH2 bzw DIF an und bei 1 Kanal Ausf hrung werden hier Min Max oder Holdwerte angezeigt 4 Logg erscheint falls Loggerfunktion ausgew hlt wurde und blinkt bei laufendem Logger AL blinkt falls Alarm vorliegt Tara signalisiert ob Tara Funktion aktiviert ist Einheiten ein Pfeil zeigt auf die gew hlte Messeinheit SL erscheint bei aktivierter H henkorrektur Sea Level co AO N D ONOM 1 5 Bedienung Beim Einschalten wird fal
13. to the operating instructions and also the relevant local regulations regarding the use of electrical equipment for hazardous areas e g VDE 0165 WIKA Operating Instructions Hand Held Pressure Indicator 21 Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex 1 2 3 Pr f und Zertifizierungsstelle ZELM x EC TYPE EXAMINATION CERTIFICATE Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Directive 94 9 EC EC TYPE EXAMINATION CERTIFICATE Number ZELM 03 ATEX 0159 X Equipment Handheld Pressure Meter type CPH 6200 ex and corresponding pressure sensor Manufacturer WIKA Alexander Wiegand GmbH amp Co KG Address D 63911 Klingenberg This equipment and any acceptable vanation thereto are specified in the schedule to this certificate and the documents therein referred to The Pruf und Zertifizierungsstelle ZELM Ex notified body No 0820 in accordance with Article 9 of the Council Directive 94 9 EC of 23 March 1994 certifies that this equipment has been found to comply with the Essential Health and Safety Requirements relating to the design and con struction of equipment and protective systems intended for use in potentially explosive atmos pheres given in Annex Il to the Directive The examination and test results are recorded in the confidential report ZELM Ex 0590315211 Compliance with the Essential Health and Safety Requirements has been ass
14. 10 ms Bei zyklischer Loggerfunktion werden jeweils der arithmetische Mittelwert der h chste und der niedrigste Druck des Intervalls aufgezeich net Erh hter Stromverbrauch Messung ist st rungsempfindlich auch gegen ber elektromagnetischen St rungen 2 3 3 rAtE FASt Fast Schnelle Messung Messfrequenz gt 100 Hz aber das Messsignal wird gefiltert wiedergegeben weniger st rungsempfindlich kurze Spitzen werden herausgefiltert ansonsten identisch zu rAtE P dEt 2 4 Mittelwertbildung Die Mittelwertbildung bezieht sich auf die Anzeigewerte Display und Schnittstelle Sie ist komplett unabh ngig von der Mittelwertbildung der Loggerfunktion bitte nicht verwechseln Die Mittelwertbildung integriert ber eine einstellbare Zeit s mtliche Messwerte und errechnet dann den resultierenden gemittelten Anzeige wert Die Funktion ist unabh ngig von der Messart schnelle langsame Messung Solange noch nicht eine ausreichend lange eingestellte Zeit in Sekunden gemessen wurde um den Mittelwert errechnen zu k nnen wird in der Anzeige angezeigt in der unteren Anzeige erscheint ein Count down W hrend des Low Power Loggerbetriebes ist die Mittelwertbildung immer deaktiviert WIKA Betriebsanleitung Hand Held Druckmessgerat 37 Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex Funktion des Min Max Wertspeichers in Kombination mit der Mittelwert bildung m Ist die Mittelwertbildung aktiviert
15. Bescheinigungen Soll das Messger t einen Kalibrierschein erhalten ist dieses mit dem zugeh rigen F hler zum Hersteller einzuschicken Nur der Hersteller kann die Grundeinstellungen berpr fen und wenn notwendig korrigieren 10 Technische Daten Messeing nge 1Eingang bei CPH 6200 CPH 6200 Ex 2 Eing nge bei CPH 6200 D Messbereich in bar 0 1 0 16 0 25 0 4 0 6 1 0 1 6 2 5 14 0 6 0 berlastgrenze in bar 1 K Z 2 4 5 10 10 17 35 Berstdruck in bar 2 2 24 2 4 4 8 6 12 12 20 5 42 Aufl sung in mbar 0 1 1 Messbereich in bar 10 16 25 40 60 100 160 250 400 600 1000 Uberlastgrenze in bar 35 80 50 80 120 200 320 500 800 1200 1500 Berstdruck in bar 42 96 250 400 550 800 1000 1200 1700 2400 3000 Aufl sung in bar 0 01 0 1 1 Druckart Relativdruck Absolutdruck von 0 25 bis 16 bar amp Vakuummessbe reiche auf Anfrage Messunsicherheit der 0 2 FS 1 Digit bei Referenztemperatur von 20 C Messkette Kalibrierung Werkskalibrierschein optional DKD Kalibrierschein Anzeige gro es LCD Display zur Anzeige von 2 vierstelligen Werten und Zusatzinformation Anzeigebereich maximal 1999 bis 9999 Digit je nach verwendetem Sensor Druckeinheiten mbar bar Pa kPa MPa mmHg psi abh ngig v Messbereich frei w hlbar CPH 6200 Digitalger t spezifische Angaben Funktionen via Tastendruck Min Max Speicher Hold Tara Nullpunkt Abgle
16. ELM 03 ATEX 0159 X Description of equipment The handheld pressure meter is designed for measuring of absolute and or relative pressure The measurement occurs by means of the corresponding external pressure sensor For supply a internal replaceable 9V block battery is used The permissible ambient temperature range is 0 to 50 C Report No ZELM Ex 0590315211 Special conditions for safe use 1 As a battery a 9 V block of the dimension 6F22 in zinc carbon technology is to be used 2 Battery exchange must only be made outside of the hazardous area 3 Inside the hazardous area the corresponding leather pocket is to be used 4 The connection to the interface socket is only permitted by means of the corresponding elec trically isolated interface adapter The connection is only permitted outside of the hazardous area For connection to terminais for external sensors only the associated sensors are permitted to use 6 The permissible ambient temperature range is O to 50 C Essential Health and Safety Requirements met by standards Zertifizierungsstelle ZELM x Braunschweig August 04 2003 Po Er Dipl Ing Harald Zeim Sheet 2 2 EC type exam nation Certficates wihout signature and stamp are not vabad The certificates may only be cwculated without alteration Extracts or alleratons are subject to approval by the Pr f und Zent zerungsstelle ZEUM Ex This Engish version is based on the German text In the case of cispute the Ge
17. Konfiguration des Ger tes 2 1 UNIT Verschiedene Druckeinheiten 2 2 SL H henkorrektur bei Absolutdruck Sensoren 2 3 RATE Verschiedene Messarten rAtE Slo P dEt FASt 2 3 1 rAtE Slo Standardmessung 2 3 2 rAtE P dEt Peak detection Spitzenwertdetektion 2 3 3 rAtE FASt Fast Schnelle Messung 2 4 Mittelwertbildung 2 5 PoFF Abschaltverz gerung 2 6 ADR Schnittstellen Adresse 2 7 AL Alarm 2 8 CLOC Echtzeituhr 3 _Wassertiefen Niveaumessung Anzeigeeinheit M 4 Bedienung der Loggerfunktion 4 1 FUNC STOR Einzelwerte speichern 4 2 FUNC CYCL Autom Aufzeichnung mit einstellbarer Zykluszeit 5 Die serielle Schnittstelle 6 Verf gbare Drucksensoren 7 Fehler und Systemmeldungen 8 Sicherheitshinweis zum Ex Betrieb 9 Hinweis zum Kalibrierservice 10 Technische Daten 11 Zubeh r WIKA Betriebsanleitung Hand Held Druckmessger t 39 40 41 43 43 44 45 48 48 49 27 Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex 28 1 Allgemeines In den folgenden Kapiteln erhalten Sie nahere Informationen zum Hand Held Messger t CPH 6200 und seinen ordnungsgem en Einsatz Sollten Sie weitere Informationen w nschen oder treten besondere Probleme auf die in der Betriebsanleitung nicht ausf hrlich behandelt werden erhalten Sie Auskunft unter den auf der letzten Seite aufgelisteten Adressen Bei der Werkskalibrierung der Instrumente wurde sich an ent
18. Operating Instructions Betriebsanleitung Hand Held Pressure Indicator GB Hand Held Druckmessger t CPH 6200 CPH 6200 D CPH 6200 Ex Kai Hand Held Druckmessger t CPH 6200 WIKA i Part of your business Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex GBI Operating Instructions Hand Held Pressure Indicator Page 3 25 D Betriebsanleitung Hand Held Druckmessger t Seite 26 49 Information This symbol provides you with information notes and tips mie Warning This Symbol warns you against actions that can cause injury to people or damage to the instrument 2 WIKA Operating Instructions Hand Held Pressure Indicator 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex 10 11 General General safety instructions Operation and maintenance advice Electrical Connections Display Basic operation Configuration UNIT Choice of pressure units SL Sea level correction for absolute pressure sensors RATE Choice of measuring rates rAtE Slo P dEt FASt 2 3 1 rAtE Slo Standard measuring 2 3 2 rAtE P dEt Peak detection 2 3 3 rAtE FASt Fast filtered measuring Averaging function P oFF Power off function ADR Communication Function AL Alarm CLOC Real time clock Measuring of water level display unit M Operation of logger FUNC STOR Storing discrete measurements FUNC CYCL Automatic d
19. S A 87 800 Wloclawek Phone 48 542 31 38 41 Fax 48 542 31 50 63 E mail gawel manometry com pl www manometry com pl Russia ZAO WIKA MERA 127015 Moskau Phone 7 095 786 21 25 Fax 7 095 786 21 23 E mail info wika ru www wika ru Serbia and Montenegro WIKA Merna Tehnika d o o 11060 Belgrad Phone 381 11 27 63 722 Fax 381 11 75 36 74 Mail info wika co yu www wika co yu Spain Instrumentos WIKA S A 08280 Sabadell Barcelona Phone 34 90 290 25 77 Fax 34 93 393 86 66 E mail info wika es www wika es Switzerland MANOMETER AG 6285 Hitzkirch Phone 41 41 919 72 72 Fax 41 41 919 72 73 E mail info manometer ch www manometer ch Ukraine WIKA Pribor GmbH 83112 Donetsk Phone 38 062 382 67 92 Fax 38 062 382 67 92 E mail info wika donetsk ua United Kingdom WIKA Instruments Limited Coulsdon Surrey CR5 2UD Phone 44 20 87 63 60 00 Fax 44 20 87 63 60 60 E mail info wika co uk www wika co uk North America Canada WIKA Instruments Ltd Head Office Edmonton Alberta T6N 1C8 Phone 1 780 463 70 35 Fax 1 780 462 00 17 E mail info wika ca www wika ca WIKA Instruments Canada Ltd Oakville Ontario LGH 6Z8 Phone 1 905 337 16 11 Fax 1 905 337 27 16 E mail info wika ca www wika ca Mexico Instrumentos WIKA Mexico S A de C V 01219 Mexico D F Phone 52 555 020 53 00 Fax 52 555 020 53 01 E Mail ventas wika com mx
20. Safety instructions for Ex operation GB Additional operating instruction To be read in conjunction with the general safety instructions in Section 1 1 E Battery operation Only 9V zinc carbon batteries according to IEC 6F22 can be used The battery must only be changed outside of the hazardous area m Mains operation The mains adapter described in the user manual is not available for the CPH 6200 Ex series E Pressure sensor Only CPT 6210 sensors can be used Using any other sensors may result in damage to both sensor and device Please only use original WIKA connecting cable provided specifically for connecting the CPT 6210 to the CPH 6200 Ex digital instrument The same applies to the extension cable which may be used to a maximum permissible length of 5m m Alarm function The audible alarm described in the user manual is not available for these devices There is therefore no difference between the two settings Alarm on and Alarm no So E Serial Interface Only the serial interface converter available from WIKA should be used for this application The serial interface must not be used within an Ex Protection Zone E Ex Zone usage The instrument must be in its accompanying leather case if it is to be used within an Ex Zone m Temperature range The permissible ambient temperature range is 0 C 50 C The instrument must not be used below 0 C Additional Ex safety instructions Please adhere
21. anleitung Hand Held Druckmessger t 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex leistet werden wenn die nationalen Sicherheits und Unfall verh tungsvorschriften sowie die Sicherheitshinweise der Betriebsanleitung beachtet werden 1 Die einwandfreie Funktion und Betriebssicherheit des Gerates kann nur unter den klimatischen Verh ltnissen die im Kapitel Technische Daten spezifiziert sind eingehalten werden 2 Ger t und Sensor m ssen pfleglich behandelt werden nicht werfen aufschlagen etc Stecker und Buchsen sind vor Verschmutzung zu sch tzen 3 Wird das Ger t von einer kalten in eine warme Umgebung transportiert so kann durch Kondensatbildung eine St rung der Ger tefunktion ein treten In diesem Fall muss die Angleichung der Ger tetemperatur an die Raumtemperatur vor einer erneuten Inbetriebnahme abgewartet werden 4 Konzipieren Sie die Beschaltung beim Anschluss an andere Ger te be sonders sorgf ltig Unter Umst nden k nnen interne Verbindungen in Fremdger ten z B Verbindung GND mit Erde zu nicht erlaubten Span nungspotentialen f hren die das Ger t selbst oder ein Angeschlossenes Ger t in seiner Funktion beeintr chtigen oder sogar zerst ren k nnen Bei Betrieb mit einem defekten Netzger t z B Kurzschluss von Netzspannung zur Ausgangsspannung k nnen am Ger t lebensgef hrliche Spannungen auftreten 5 Wenn anzunehm
22. ara Funktion Durch Dr cken der Taste Tara wird die Anzeige auf 0 ge setzt Alle Messungen werden von nun an relativ zu dem gesetzten Tara Wert angezeigt Ist die Tara Funktion akti viert wird der Pfeil Tara angezeigt Zum Deaktivieren die Taste Tara f r gt 2 sec gedr ckt halten Beim Aktivieren von Tara werden Max amp Min Speicher gel scht Nullpunktabgleich f r Relativdruck Sensoren Wenn an den Druckstut zen kein Druck angelegt wird zeigt das Ger t 0 an Sollte jedoch doch eine st ndige Abweichung vorhanden sein bei Betrieb in st rungsfreien Umgebungsbedingungen so besteht die M glichkeit einen dauerhaften Nullpunktab gleich durchzuf hren Um einen Nullpunktabgleich durch zuf hren die Taste Tara f r ca 5 sec lang dr cken Nur m glich wenn Anzeigewert weniger als 2 von der Werkskalibrierung abweicht z B 0 25 bar gt Nullpunkt abgleich bis 0 5 bar m glich Wiederherstellen der Werks kalibrierung Tara Taste f r ca 7 sec lang dr cken Wurde ein Nullpunktabgleich durchgef hrt wird dies beim Einschalten des Ger tes mit der Meldung NuLL Corr signalisiert Differenzbildung Durch Dr cken der Set Menu Taste wird in der Neben anzeige die Differenz von Kanal 1 Kanal 2 DIF CH1 CH2 angezeigt Erneutes Dr cken macht den Vorgang wieder r ckg ngig nur bei 2 Kanal Ausf hrung und 2 angeschlos senen Sensoren WIKA Betriebsanleitung Hand Held Druckmessger t 33
23. atalogging with adjustable Cycle Time The serial interface Available pressure sensors Fault and system messages Safety instructions for Ex operation Calibration services Specification Accessories WIKA Operating Instructions Hand Held Pressure Indicator 15 15 15 17 19 19 20 21 24 24 25 Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex 1 General In the following chapters detailed information on the hand held pressure indicator CPH 6200 and its proper use can be found Should you require further information or should there be problems which are not dealt within detail in the operating instructions please contact the address listed on the last page Factory calibration of the instrument is according to relevant international standards The warranty period for the CPH 6200 hand held pressure indicator is 24 months according to the general terms of supply of ZVEI The guarantee is void if the appliance is put to improper use or ifthe operating instructions are not observed or if an attempt is made to open the appliance We also point out that the content of these operating instructions neither forms part of an earlier or existing agreement assurance or legal relations hip nor is meant to change these All obligations of WIKA Alexander Wiegand GmbH amp Co KG result from the respective sales contract and the general business terms of WIKA Alexander Wiegand GmbH amp Co KG
24. cator CPH 6200 CPH 6200 D CPH 6200 Ex If the instrument is a type CPH 6200 Ex intrinsically safe hand held pressure indicator the additional safety instructions regarding the Ex operation described in Section 8 must be strictly observed 1 2 Operation and maintenance advice m Battery Operation If A and bAt are shown in the lower display the battery is low and needs to be replaced or recharged using the appropriate battery charger as shown in the current CPH 6200 price list The device will however work normally for a limited period If pAt is shown in the upper display the voltage is too low to operate the device the battery will be completely flat If the device is not going to be used for some time we advise that the battery is removed m Mains operation with power supply When using a power supply please note that the operating voltage must be 10 5 to 12 V DC Do not use with higher voltages Cheap 12 V power supplies often have excessive no load voltage and we therefore recommend using regulated voltage power supplies Trouble free operation can be ensured by using our own power supply unit see current CPH 6200 price list Before connecting the power supply to the mains make sure that its operating voltage matches the local mains voltage m Connecting Changing Sensors Only use sensors model CPT 6200 Using other sensors can damage the instrument Switch off device before changing the sensor and connec
25. ckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex 40 4 1 Func Stor Einzelwerte speichern Jeweils ein Messergebnis wird aufgezeichnet wenn die Taste Store Quit gedr ckt wird Die gespeicherten Daten k nnen in der Anzeige selbst betrachtet werden bei Aufrufen der Konfiguration erscheint ein zus tzli ches Men REAd LoGG oder mit Hilfe der Schnittstelle in einen PC eingelesen werden Speicherbare Datens tze 99 Ein Datensatz besteht max aus Sensor 1 Messwert zum Zeitpunkt des Speicherns Sensor 1 Min Peak Max Peak seit dem letzten Speichern Sensor 2 Messwert zum Zeitpunkt des Speicherns Sensor 2 Min Peak Max Peak seit dem letzten Speichern Differenz Sensor 1 Sensor 2 Messwert zum Zeitpunkt des Speicherns Differenz Sensor 1 Sensor 2 Min Peak Max Peak seit dem letzten Speichern m Uhrzeit und Datum zum Zeitpunkt des Speicherns Gilt nur f r 2 Kanal Version CPH 6200 D Bei jedem Speichern wird kurz St XX angezeigt XX ist dabei die Nummer des Messergebnisses Wenn bereits Daten gespeichert wurden Wird Taste Store 2 sek lang gedr ckt wird die Auswahl zum L schen des Loggerspeichers angezeigt N Alle Datens tze r r l schen pog LE no Nicht l schen Vor r L gang abbrechen FI r rh Den zuletzt aufge uf zeichneten Daten LASE satz l schen Die Auswahl erfolgt mit Tasten Min bzw Max Mit Store Quit wird die Auswahl quittiert Falls der Lo
26. diger Ausf hrung mit integrierter K hlstrecke 3 Bei Ausf hrung f r Sauersto darf eine Messstofftemperatur von 60 C nicht berschritten werden Nicht m glich bei Absolutdruck Messbereichen lt 1 bar abs Angaben in geschweiften Klammern beschreiben gegen Mehrpreis lieferbare Sonderheiten 11 Zubeh r Zubeh r wie Druckerzeugung pneumatisch hydraulisch Druckschl uche Adapter Dataloggerauswertesoftware GSoft oder Kalibriersoftware Prozess Anschlussadapter Netzger t Akkuladeger t Akku etc finden Sie in der aktuelle WIKA Preisliste Pr f und Kalibriertechnik WIKA Betriebsanleitung Hand Held Druckmessger t 49 Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex 50 WIKA Betriebsanleitung Hand Held Druckmessgerat 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D WIKA Global 18 Adressen Addresses South America Argentina WIKA Argentina S A Buenos Aires Phone 54 11 4730 18 00 Fax 454 11 4761 00 50 E mail info wika com ar www wika com ar Brazil WIKA do Brasil Ind e Com Ltda CEP 18560 000 Iper SP Phone 55 15 3266 16 55 Fax 55 15 3266 16 50 E mail marketing wika com br www wika com br Africa Middle East Iran WIKA Instrumentation Pars KFZ Ltd Anahita Tower Tehran Phone 98 21 8878 3514 17 Fax 98 21 8887 8593 E mail info wika ir www wika ir South Africa WIKA Instruments Pty Ltd Gardenview Johannesburg 2047
27. e number of the data point 1 9999 WIKA Operating Instructions Hand Held Pressure Indicator 17 Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex 18 If the logger memory is full the display will show Recording will be stopped automatically If the Low Power Logger Function is selected Lo Po on the device switches itself off as soon as the memory becomes full Stopping the logging manually By pressing the Store Quit key recording can be manually interrupted The following choice then appears ok a P Stop G o P Do not stop JES recording no recording The selection can be made by key Max and key Min key Store Quit enters the choice If you try to switch off the instrument during a logging cycle you will also be asked if you wish to stop recording The device can only be switched off after the recording has been stopped The Auto Power Off function is deactivated during logging Clear Data When the Store Quit key is pressed for 2 seconds the option to clear the logger memory will be displayed ra clear all m clear nothing sti data points a cancel opera tion The options are selected by the Max key and the Min key Store Quit confirms the choice WIKA Operating Instructions Hand Held Pressure Indicator 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex 5 T
28. ebungstemperaturbereich betr gt 0 bis 50 C Pr fbericht Nr ZELM Ex 0590315211 Besondere Bedingungen Als Batterie ist ein 9 V Block der Baugr e 6F 22 in Zink Kohle Technologie zu verwenden Der Batterietausch darf nur au erhalb des explosionsgef hrdeten Bereiches erfolgen Im explosionsgef hrdeten Bereich ist die zugeh rige Ledertasche zu verwenden Der Anschluss an die Schnittstellenbuchse ist nur mittels des zugeh rigen Schnittstellen wandlers mit galvanischer Trennung zul ssig Der Anschluss darf nur au erhalb des explo sionsgef hrdeten Bereiches erfolgen Zum Anschluss an die Buchse f r externe Sensoren sind ausschlie lich die zugeh rigen Sensoren zu verwenden Der zul ssige Umgebungstemperaturbereich betr gt 0 bis 50 C Grundlegende Sicherheits und Gesundheitsanforderungen durch Normen erf llt Zertifizierungsstelle ZELM x Braunschweig 04 08 2003 I L Dipl Ing Hafald Zelim t EG Baumusterprufbescheinigungen ohne Unterschrift und ohne Stempel haben keine G tigkeit Diese EG Baumusterpr fbescheinigung darf nur unver ndert wettervertretet werden Ausz ge oder Anderungen bed rfen der Genehmigung der Pr f und Zertfizerungsstelle ZELM Ex Prut und Zertfzwerungsstele ZELM Ex Suehgraben 56 D 38124 Braunschweig WIKA Betriebsanleitung Hand Held Druckmessger t 47 Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex 9 Hinweis zum Kalibrierservice D DKD Schein amtliche
29. en ist dass das Ger t nicht mehr gefahrlos betrieben werden kann so ist es au er Betrieb zu setzen und vor einer Wieder inbetriebnahme durch Kennzeichnung zu sichern Die Sicherheit des Benutzers kann durch das Ger t beeintr chtigt sein wenn es zum Beispiel m Sichtbare Sch den aufweist m Nicht mehr wie vorgeschrieben arbeitet m L ngere Zeit unter ungeeigneten Bedingungen gelagert wurde In Zweifelsf llen das Ger t grunds tzlich an den Hersteller zur Repara tur bzw Wartung einschicken 6 Es d rfen am Ger t keine Ver nderungen oder Reparaturen vom Kunden vorgenommen werden Zur Wartung oder Reparatur muss das Ger t zum Hersteller eingesandt werden 7 Ein anderer Betrieb als der in der folgenden Anleitung beschriebene oder au erhalb der Spezifikationen ist bestimmungswidrig und muss deshalb ausgeschlossen werden Handelt es sich um eine Explosionsgesch tzte Ausf hrung CPH 6200 Ex sind unbedingt auch die Sicherheitshinweise zum Ex Betrieb welche in Kapitel 8 beschrieben sind zu beachten WIKA Betriebsanleitung Hand Held Druckmessger t 29 Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex 30 mie 1 2 Betriebs und Wartungshinweise m Batteriebetrieb Wird A und in der unteren Anzeige bAt angezeigt so ist die Batterie verbraucht und muss erneuert werden bzw der Akku ist leer und muss mit dem daf r vorgesehen Akkuladeger t siehe aktuelle Preisliste CPH 6200 geladen werden Jedoch ist
30. er data is being read by the When the data transfer is completed serial interface the device will automatically return to normal measuring display no remedy necessary No Battery flat Replace battery display or strange Mains operation without battery Check power supply change it if symbols wrong voltage or polarity necessary device is not res System error Disconnect battery or power supply ponding wait a while re connect to input Instrument faulty Return to manufacturer for repair Err 1 Measured value above allowable Check Is the pressure outside the range sensor s range gt measured value too high Sensor faulty Return to manufacturer for repair Err 2 Measured value below allowable Check Is the pressure outside the range sensor s range gt measured value too low Sensor defective Return to manufacturer for repair Err 4 Value is too low to be displayed tare Check is value below 2000 is set check tare Err 7 System error Return to manufacturer for repair Err 9 Connected sensor or device faulty If second sensor available check if device is ok Return defective device sensor to manufacturer for repair Measured value is far above or below allowable range Check Is the pressure outside the sensor s range WIKA Operating Instructions Hand Held Pressure Indicator 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex 8
31. es betrieben werden Kalibriert bei senkrechter Einbaulage Druckanschluss nach unten Entfallt bei der eigensicheren Version CPH 6200 Ex Angaben in geschweiften Klammern beschreiben gegen Mehrpreis lieferbare Sonderheiten 48 WIKA Betriebsanleitung Hand Held Druckmessgerat 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex CPT Drucktransmitter spezifische Angaben Druckanschluss Werkstoff Interne Ubertragungs fl ssigkeit G B frontb ndig G1 f r 0 1 bis 1 6 bar bzw diverse An schlussadapter auf Anfrage Messstoffber hrte Teile CrNi Stahl Geh use CrNi Stahl Frontb ndige Ausf hrung CrNi Stahl Hastelloy C4 O Ring NBR Viton oder EPDM Synthetisches Ol Nur bei Messbereichen bis 16 bar oder frontb ndige Membrane Halocarbon l f r Sauerstoff Aus f hrungen FDA gelistet f r Nahrungsmittelindustrie Stabilit t pro Jahr 0 2 d Sp bei Referenzbedingungen zul ssige Messstofftemperatur 9 25 100 C Umgebungstemperatur 0 50 C Lagertemperatur 40 80 C kompensierter Bereich 0 70 C Temperaturkoeffizienten mittlerer TK des Nullpunktes mittlerer TK der Messspanne 0 2 10 K lt 0 4 f r Messbereiche lt 250 mbar 0 2 10K Anschluss an das CPH 6200 via 1 m Verbindungskabel optional bis zu 5 m Masse ca 220g 2 O Ring aus Viton oder EPDM bei frontb n
32. g is necessary use a cloth wetted with mild detergent Avoid any solvents caustic or abrasive substances As is normal for all measuring instruments the accuracy of the device should be tested at regular intervals approx once per year see Section 9 1 3 Electrical Connections On the upper edge of the device The connector sockets for attaching the CPH series pressure sensors CH1 and CH2 CH2 only with the 2 channel version are located on the top edge of the CPH 6200 see Section 6 as is the socket for the serial interface adapter see Section 5 Connection for serial interface adapter CH1 CH2 only for 2 channel version CPH 6200 D On the left side of the device The mains adapter socket for connecting the power supply unit see current CPH 6200 price list is located on the left side of the handheld unit WIKA Operating Instructions Hand Held Pressure Indicator 7 Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex GBI 1 4 Display hh 2 8888 N Main display shows the current measured value of CH1 2 A indicates a low battery and other warnings 3 Lower display For 2 channel version shows the measured value of CH2 or DIF CH1 CH2 For 1 channel version it displays the min max or hold function values Logg Shown if logger function is selected flashes if cyclic logger is running AL flashes if alarm is present Tara indicates that tare function is ac
33. ge 2 8 CLOC Real time clock The real time clock is needed for time stamping each data point recorded within the logger function As a result the clock settings should be checked regularly If the battery has been replaced the appropriate menu CLOC will be accessed automatically WIKA Operating Instructions Hand Held Pressure Indicator 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex 3 Measuring of water level display unit m In preparation 4 Operation of logger The device supports two different logger functions Func Stor each time the Store Quit key is pressed a data point will be recorded Func CYCL measurements will automatically be recorded at a defined interval set within the logger menu CYCL until the logger is stopped or the logger memory becomes full Logging is started by pressing the Store Quit key for 2 seconds The logger records 3 measurement values for each interval m Instantaneous or mean value depending on logger setting see below Min Peak and Max Peak To evaluate the data WIKA s Data logger evaluation software GSOFT V 1 7 or higher must be used The software also allows easy configuration and operation of the logger 7 If the logger is selected Func Stor or Func CYCL the hold function is deactivated the Store Quit key is then used solely for 7 the operation of the logger funct
34. gef hrdeten Bereiches erfolgen m Netzger tebetrieb Die in der Bedienungsanleitung beschriebene Netzger tebuchse ist bei den Ger ten der CPH 6200 Ex Serie nicht vorhanden m Drucksensor Es d rfen nur CPT 6210 Sensoren verwendet werden Mit anderen Senso ren kann es zur Zerst rung des Messger tes und des Sensors kommen F r die elektrische Verbindung zwischen Drucktransmitter CPT 6210 und Digitalger t CPH 6200 Ex ist nur das hierf r vorgesehene original WIKA Anschlusskabel zu verwenden Dies gilt ebenfalls f r das Verl ngerungskabel womit die maximal zul ssige Gesamtkabell nge von knapp 5 m erreicht wird m Alarmfunktion Die in der Bedienungsanleitung beschriebene Hupe ist bei diesen Ger ten nicht vorhanden Die Alarmeinstellung on verh lt sich somit wie no So m Schnittstellenanschluss Als Schnittstellenwandler darf nur der von WIKA hierf r angebotene eingesetzt werden Der Betrieb der seriellen Schnittstelle ist im Ex Bereich nicht zul ssig m Ex Betrieb Das Ger t darf im Ex Bereich nur in der zugeh rigen Lederta sche betrieben werden E Temperaturbereich Das Ger t darf unter 0 C nicht betrieben werden Zul ssige Umgebungstemperatur 0 C 50 C Zus tzliche Ex Sicherheitshinweise Beachten Sie die Betriebshinweise sowie die jeweiligen Landesvorschriftenbez glich Ex Einsatz z B VDE 0165 WIKA Betriebsanleitung Hand Held Druckmessger t 45 Hand Held Druckmessgerat
35. ggerspeicher voll ist erscheint WIKA Betriebsanleitung Hand Held Druckmessger t 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex Einzelwerte betrachten Im Gegensatz zur zyklischen Loggerfunktion k nnen Einzelwerte auch direkt in der Anzeige betrachtet werden 2 sek lang Set Menu dr cken als erstes Men wird jetzt rEAd LoGG Logger auslesen angeboten Nach Dr cken der Taste Tara wird das letzte Messergebnis gezeigt das Wechseln zwischen den Werten eines Messergebnisses erfolgt ebenfalls mit Tara Das Wechseln zu anderen Messergebnissen erfolgt mit den Tasten Max oder Min 4 2 Func CYCL Autom Aufzeichnung mit einstellbarer Zykluszeit Die Logger Zykluszeit ist einstellbar siehe Konfiguration Beispielsweise CYCL 60 alle 60 Sekunden wird ein Messergebnis abgespeichert Zus tzlich ist bei Messart rAtE Slo eine Stromsparfunktion w hlbar Lo Po Ist diese on bewirkt dies dass w hrend der Logger aufzeichnet eine Messung nur zum jeweiligen Logger Zeitpunkt stattfindet Dies senkt den Stromverbrauch erheblich und empfiehlt sich daher vor allem f r Langzeitmessungen z B Dichtigkeitspr fungen bei denen kein Netzger t zur Verf gung steht Speicherbare Messergebnisse 9999 Zykluszeit 1 3600sek 1h einstellbar in der Kon figuration Ein Messergebnis besteht aus m Langsamen Messungen rAtE SLo Sensor 1 M
36. gung hingewie sen Diese EG Baumusterpr fbescheinigung bezieht sich nur auf Konstruktion berpr fung und Tests des spezifizieren Ger tes oder Schutzsystems in bereinstimmung mit Richtlinie 94 9 EG Weitere Anforderungen der Richtlinie k nnen f r das Herstellungsverfahren und die Lieferung dieses Ger tes oder Schutzsystems gelten Diese sind von vorliegender Bescheini gung nicht abgedeckt Die Kennzeichnung des Ger tes mu die folgenden Angaben enthalten amp 1126 EExibIICT4 Zertifizierungsstelle ZELM x Braunschweig 04 08 2003 Ae de m Dipl Ing Hasald Zeim EG Baumusterpr fdescheingungen ohne Unterschrift und ohne Stempel haben keine G ligkot Diese EG Baumusterpr fbescheingung darf nur unver ndert weterverbrodet worden Auszuge oder nderungen bed rfen der Genehmigung der Prif und Zertfizerungsstetie ZELM Ex Pruf und Zerttuzwerungsstele ZELM Ex S ekgraben 56 D 38124 Braunschwog WIKA Betriebsanleitung Hand Held Druckmessger t 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex Pr f und Zertifizierungsstelle ZELM amp x Anlage EG Baumusterpr fbescheinigung ZELM 03 ATEX 0159 X Beschreibung des Ger tes Das Hand Held Druckmessgerat dient zur Messung von Absolut und oder Relativdruck Die Messung erfolgt mit zugeh rigem externen Drucksensor Die Versorgung erfolgt aus einer eingebauten 9V Blockbatterie Der zul ssige Umg
37. haltet sich das Ger t ab sobald der Loggerspeicher gef llt ist Loggeraufzeichnung Stoppen Durch kurzes Dr cken von Store Quit kann die Aufzeichnung gestoppt werden Es erscheint dann eine Sicherheitsabfrage Gh o p Aufzeichnung Gk I p Die Aufzeichnung YES stoppen aes nicht stoppen Die Auswahl erfolgt mit Tasten Min bzw Max Mit Store Quit wird die Auswahl quittiert Wird versucht ein mit zyklischer Aufzeichnung laufendes Messger t auszuschalten so wird automatisch nachgefragt ob die Aufzeichnung gestoppt werden soll Nur bei gestoppter Aufzeichnung kann das Ger t abgeschaltet werden Die Auto Power Off Funktion ist bei laufender Aufzeichnung deaktiviert Loggeraufzeichnung l schen Wird die Taste Store Quit f r 2 Sekunden gedr ckt so wird falls Loggerdaten vorhanden die Auswahl zum L schen des Loggerspeichers angezeigt L r Alle Datens tze m Nicht l schen Vor ALL l schen w gang abbrechen Die Auswahl erfolgt mit Tasten Min bzw Max Mit Store Quit wird die Auswahl quittiert WIKA Betriebsanleitung Hand Held Druckmessger t 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex 5 Die serielle Schnittstelle Fur den Datentransfer zu einem Computer existieren 2 galvanisch getrenn EF te Schnittstellenkonverter siehe Preisliste Pr f und Kalibriertechnik einmal f r den Anschluss an RS 232 u
38. he serial interface For data transfer to a computer there are two electrically isolated interface adapters available for the connection of the CPH 6200 to a RS 232 or USB interface USB driver necessary WIKA s Data logger evaluation software GSOFT see current CPH 6200 price list is used to display the data To avoid transmission errors there are several security features implemented e g CRC 6 Available pressure sensors The instrument has been designed so that all sensors model CPT 6200 can be connected without the need for any configuration or recalibration There is therefore a wide range of interchangeable sensors available with ranges of up to 1000 bar see current price list for model CPT 6200 and CPT 6210 pressure transmitters WIKA Operating Instructions Hand Held Pressure Indicator 19 Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex 20 7 Fault and system messages Display Meaning Remedy Int Low battery power device will only Replace battery ABE a work for a short while longer bAt Battery flat Replace battery Mains operation without battery wrong voltage Check power supply change it if necessary SEnS No sensor connected Switch off device and connect Erro sensor Connected sensor or device faulty If second sensor available check if device is ok Return defective device sensor to manufacturer for repair DEZE Logg
39. hnet Das Ger t ist in der Lage diese Luftdruck H henkorrektur vorzunehmen Aktivieren Sie hierzu die Sea Level Funktion SL Bei aktivierter Sea Level Funktion wird unten in der Anzeige der Pfeil f r SL angezeigt Wurde die H he des Aufenthaltsortes ber dem Meeres spiegel eingegeben Alti zeigt das Ger t jetzt den Absolutdruck auf Meeresh he bezogen an 2 3 RatE Verschiedene Messarten rAtE Slo P dEt FASt Das Ger t unterst tzt 3 verschiede Messarten f r verschiedene Anwen dungszwecke Zwei davon arbeiten mit einer erh hten Messfrequenz von gt 100 Messungen sek Ist eine der beiden aktiv wird in der unteren Anzeige entsprechend P dEt oder FASt angezeigt WIKA Betriebsanleitung Hand Held Druckmessger t 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex 2 3 1 rAtE Slo Standardmessung Messfrequenz 4 Hz Mittelungsverfahren und Messfilter sind aktiv Anwen dungsbereich Messen von langsamen Druckanderungen und statischen Dr cken z B Kalibrierungen Dichtheitspr fungen Luftdruckmess u H chste Messgenauigkeit st rungsunempfindlich niedriger Stromver brauch 2 3 2 rAtE P dEt Peak detection Spitzenwertdetektion Messfrequenz gt 100 Hz das Messsignal wird ungefiltert wiedergegeben Anwendungsbereich in Verbindung mit Logger Funktion Messen von Spitzendr cken und schnellen Druckschwankungen mit einer Aufl sung lt
40. ich Logger Start Stop Funktionen via Men Min Max Alarm akustisch visuell Sealevel barom Luftdruck Power Off Funktion Messrate 4 sec slow gt 100 sec fast gt 100 sec ungefiltert peak detect mittels peak detect werden im Min Max Speicher Druckspitzen mit 10 msec Dauer erfasst Datenlogger Einzelwertlogger bis zu 99 Aufzeichnungen inkl Uhrzeit via Tasten druck Zyklischer Logger autom Aufzeichnung von bis zu 9999 Werten inkl Uhrzeit Zykluszeit w hlbar von 1 bis 3600 sec Schnittstelle seriell RS 232 Schnittstelle via Schnittstellenkonverter USB Adapter auf Anfrage Stromversorgung 9V Zink Kohle Batterie Lieferumfang alternativ 9V Akku oder Netzversorgung Stromaufnahme Messzyklus langsam lt 1 5 mA schnell lt 3 0 mA Low Power Logger Fkt lt 0 1 mA zul Umgebungstemperatur 0 50 C Relative Feuchte 0 95 r F nicht betauend Lagertemperatur 20 70 C Gehause schlagfestes ABS Kunststoff Folientastatur Klarsichtscheibe CPH 6200 Ex mit Schutzh lle Masse ca 160g EMV CE Zulassung Das CPH 6200 entspricht den grundlegenden Schutzanforderungen die in der Richtlinie des Rates zur Angleichung der Rechtsvorschriften der Mitgliederstaaten ber die elektromagnetische Vertr glichkeit 89 336 EWG festgelegt sind 1 Bei der eigensicheren Version darf die Schnittstelle nur au erhalb des explosionsgefahrdetem Bereich
41. in the lower display Pressing it again hides it Only when the main menu item logger off is selected Logger Functions Activated by the Store Quit key only if the logger has been selected via the main menu see Section 4 Tare Functions By pressing Tara the display will be set to 0 All measure ments from then on will be displayed relative to the set tare value When the tare function is activated the arrow Tara appears in the display To deactivate the tare function press Tara for gt 2 seconds see Section 4 i Activating deactivating tare clears the max amp min memories Zero Point Adjust for gauge pressure sensors only If there is no pres sure applied to the pressure ports the device will display 0 If there is a permanent offset and the device is being used under steady conditions a permanent zero point adjust ment can be carried out To carry out the adjustment press Tara for approx 5 seconds Please note A zero point adjustment can only be made if the difference between the display value and the factory calibration value is less than 2 E g for a measuring range of 0 25 bar gt zero point adjustment up to 0 5 bar possible To revert to the factory calibration press Tara for approx 7 seconds If a zero point adjustment has been made this will be signalled by the C message NuLL Corr being displayed briefly as the device is turned on I j Differential pressu
42. ions Min and Max Peak are respectively the minimum and the maximum measured values during the last measurement interval Therefore both the instantaneous pressure values and the measured fluctuations can be better analysed 4 1 Func Stor Storing Discrete Measurements In this mode each time the Store Quit key is pressed a measure ment and its time stamp will be recorded The data recorded can be viewed either on the display an additional menu item REAd LoGG is displayed when scrolling through the Configuration menu or through the serial interface and a PC running the GSOFT software WIKA Operating Instructions Hand Held Pressure Indicator 15 Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex 16 Max number of measurements 99 The data recorded includes the following values Sensor 1 instantaneous value at that data point Sensor 1 Min Peak Max Peak since last data point Sensor 2 instantaneous value at that data point Sensor 2 Min Peak Max Peak since last data point Instantaneous difference Sensor 1 Sensor 2 at that data point Min Peak Max Peak of the difference Sensor 1 Sensor 2 Min Peak Max Peak since last data point m Time and date stamp of that data point Only for 2 channel version CPH 6200 D After each recording St XX will be displayed for a short time XX represents the number of the data point If the logger memory already contains data When the Store Quit
43. isch das Uhrzeit Einstellungs Men gestartet WIKA Betriebsanleitung Hand Held Druckmessger t 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex 3 Wassertiefen Niveaumessung Anzeigeeinheit m In Vorbereitung 4 Bedienung der Loggerfunktion Grunds tzlich besitzt das Ger t zwei verschiedene Loggerfunktionen die man ber das Hauptmen aktiviert Func Stor jeweils ein Messergebnis wird aufgezeichnet wenn die Taste Store Quit gedr ckt wird Func CYCL Messergebnisse werden automatisch im Abstand der ein gestellten Zykluszeit aufgezeichnet die Aufzeichnung wird mit 2 sek lang Store Quit dr cken gestartet Der Logger zeichnet jeweils drei Messergebnisse auf m stwert oder Mittelwert je nach gew hlter Funktion Min Peak und Max Peak Zur Auswertung der Func CYCL Daten ben tigen sie die Auswerte Software GSOFT mit der auch der Logger sehr einfach gestartet und eingestellt werden kann Bei aktivierter Loggerfunktion Func Stor oder Func CYCL siehe Men f hrung des Hauptmen s steht die Hold Funktion nicht zur Verf gung Min und Max Peak sind dabei die minimal bzw maximal gemessenen Druckwerte seit dem letzten Speichervorgang Somit k nnen sowohl der aktuelle Druckwert als auch vorhandene Druckschwankungen sehr genau analysiert werden WIKA Betriebsanleitung Hand Held Druckmessgerat 39 Hand Held Dru
44. it Unit of display SL oFF on Sea level correction on or off A Alti 200 9999 Altitude Input of altitude above sea level m is only if on rAtE Rate Measuring rate see chapter 2 3 Slo Slow Measuring rate 4 Hz filtered low power j consumption FASt Fast Measuring rate filtered gt 100 Hz PdEt Peak detection fast measuring rate unfiltered gt 100 Hz t AVG 1 120 Averaging interval in seconds used by the averaging function off oFF Averaging function deactivated P oFF 1 120 Auto Power Off delay in minutes Device will automatically switch itself off if during this interval no key is pressed or there is no serial communication oFF Auto Power Off function inactive continuous operation Adr 01 11 91 Communicationsaddressof interface SEt Set Alarm Alarm Function Configuration AL AL on Alarm function on with audio alarm 1 2 DIF no So Alarm function on without audio alarm OFF No alarm function AL Lo Min Range Min alarm limit 1 2 DIF AL Hi not when AL oFF Min Range is the lower display range of the connected sensor AL Hi AL Lo Max alarm limit 1 2 DIF Max Range not when AL oFF Max Range is the upper display range of the connected sensor SEt Set Logger Logger Function Configuration LoGG Func CYCL Cyclic logger function cyclic logger Stor Store logger function discrete value logger 3 oFF No logger function CYCL 1 3600 Cycle time for cyclic logger second
45. itional information Range of display max 1999 up to 9999 depending on sensors used Units can be selected from the following mbar bar Pa kPa MPa mmHg psi dependent on range CPH 6200 Digital Instrument specific details Functions via key press Min Max memory Hold Tare Offset correction Logger Start Stop Functions via Menu Min Max alarm acoustic visual Sea level barom air pressure Power Off Function measuring rate 4 sec slow gt 100 sec fast gt 100 sec unfiltered peak detect via peak detect and min max memory pressure peaks of 10 msec can be detected Data logger discrete value logger up to 99 data points incl Time stamp via key press cyclic logger automatic logging of up to 5400 values incl time Cycle time selectable between 1 3600 seconds Interface serial RS 232 interface via interface converter USB adapter on request Power supply 9V zinc carbon battery alternative 9V rechargeable battery or mains supply Power consumption Cycle time slow lt 1 5 mA fast lt 3 0 mA Low Power Logger Fct lt 0 1 mA Working temperature 0 50 C Air humidity 0 95 relative humidity without moisture condensation Storage temperature 20 70 C Housing Impact resistant ABS membrane keyboard transparent panels CPH 6200 Ex with cover Weight Approx 160 g EMV CE conformity The CPH 6200 device corresponds to the essential protection
46. ls eine Loggerfunktion gew hlt wurde kurz die Uhrzeit angezeigt Falls ein Nullpunktabgleich durchgef hrt worden ist wird dies mit der Anzeige nuLL Corr signalisiert Nach einem Batteriewechsel erscheint automatisch das Uhrzeit Einstellungs Men CLOC berpr fen und korrigieren Sie ggf die Uhrzeit siehe Kapitel 2 oo 899 32 WIKA Betriebsanleitung Hand Held Druckmessger t 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex Ein Ausschalter Set Menu Aufruf der Konfiguration Tara Aufruf der Tara Funktion Nullpunktabgleich Store Quit Aufruf der Hold Funktion bzw der Loggerfunktionen Siehe Kapitel 5 5 min max Aufruf des Min bzw Max Speichers PON gt Max Speicher Die Taste Max zeigt den maximal gemessenen Wert Erneutes Dr cken blendet ihn wieder aus Zum L schen des Max Wertes Max f r gt 2 sec dr cken Min Speicher Die Taste Min zeigt den minimal gemessenen Wert Erneutes Dr cken blendet ihn wieder aus Zum L schen des Min Wertes Min f r gt 2 sec dr cken Hold Funktion Durch Dr cken der Taste Store Quit wird der letzte Mess wert in der unteren Anzeige gehalten Erneutes Dr cken blendet den Wert wieder aus nur falls Logger deaktiviert Logger Funktionen Aktivierung ber Store Quit Taste falls im Haupt men von Hold auf eine Logger Funktion umgeschaltet wurde siehe Kapitel 4 T
47. lute pressure sensors If an absolute pressure sensor is connected to the instrument then the device displays the true absolute pressure measured by the sensor This does not necessarily equate to the values given by weather stations which give the pressure at sea level Usually the sensor is situated above sea level and therefore if the value at sea level zero is to be measured the pressure loss resulting from the elevation above sea level must be considered To correct the displayed value activate the Sea Level Function SL Then enter the sensor s height above sea level in metres Alti When activated the display shows the SL arrow and the device displays the absolute pressure value relative to sea level 2 3 rAtE Choice of Measuring Rates rAtE Slo P dEt FASt Three options of measuring rate are supported Two of them work with high measuring frequencies of over 100 measurements per second Whichever one of them was selected during configuration WIKA Operating Instructions Hand Held Pressure Indicator 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex see above this will be displayed in the lower display P dEt or FASt 2 3 1 rAtE Slo standard measuring Measuring rate 4 Hz averaging and filter functions are active Application Measurement of slowly changing or static pressures e g leak testing atmospheric pressure Highest accu
48. n dAtE TT MM Date Einstellen des Datums Tag Monat YEAr YYYY Year Einstellen der Jahreszahl WIKA Betriebsanleitung Hand Held Druckmessger t 35 Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex 36 Befinden sich Daten im Loggerspeicher k nnen Men punkte die mit gekennzeichnet sind nicht aufgerufen werden Sollen diese ver ndert werden m ssen zun chst die Daten gel scht werden siehe Kapitel 4 2 Konfigurieren des Ger tes Zum ndern von Einstellungen 2 sec lang die Taste Set Menu dr cken dadurch wird das Men Hauptanzeige SEt aufgerufen Mit Set Menu w hlen Sie das Men und mit Tara k nnen Sie zu den zugeh rigen Parametern springen den Sie dann ver ndern k nnen Die Einstellung der Parameter erfolgt mit den Tasten Min oder Max Erneutes Dr cken von Set Menu wechselt zur ck zum Hauptmen und speichert die Einstellungen Mit Store Quit wird die Konfiguration beendet 2 1 Unit Verschiedene Druckeinheiten Abh ngig vom Messbereich des aktuellen Drucksensors kann die Einheit mbar bar Pa kPa MPa mmHg oder PSI gew hlt werden 2 2 SL H henkorrektur bei Absolutdruck Sensoren Bei angeschlossenem Absolutdrucksensor misst das Gerat den Absolut druck Dieser ist jedoch nicht mit dem von Wetterstationen angegebenen Luftdruck auf Meeresh he zu verwechseln Bei dieser Druckangabe wird die h henbedingte Luftdruckabnahme herausgerec
49. nd Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex 14 Operation of min max value memory in conjunction with the averaging function m If averaging is activated and slow measuring rate is selected rAtE Slo the min max memory value relates to the average display value m If averaging is activated and fast measuring rate is selected rAtE FASt or P dEt the min max memory value relates to the internal measured values pressure spikes can be detected 2 5 P oFF Power off function If no key is pressed and no serial communication occurs during the interval set in configuration Poff the device will automatically switch itself off to save battery power If RoFF oFF then the automatic power off is deactivated 2 6 Adr Serial communications address This parameter has been included in preparation for future operation with multi point monitoring systems 2 7 AL Alarm There are three possible settings Alarm off AL oFF on with audio alarm AL on on without audio alarm AL no So The following conditions will prompt an alarm to be displayed if the alarm function is activated on or no So m Value is below lower alarm limit AL Lo or above upper alarm limit AL Hi m Sensor error Sens Erro m Low battery bAt m Fe 7 System error always with sound When an alarm occurs the alarm arrow flashes and during serial communication the PRIO flag is set within the transmitted messa
50. nd einmal f r den Anschluss an eine USB Schnittstelle USB Treiber erforderlich 6 Verf gbare Drucksensoren Das Messger t ist so konzipiert dass alle Sensoren des Types CPT 62xx ohne Neuabgleich angesteckt werden k nnen Somit stehen Ihnen eine Vielzahl von austauschbarer Sensoren bis 1000 bar zur Auswahl siehe aktuelle Preisliste Druckmessumformer Typ CPT 6200 und CPT 6210 WIKA Betriebsanleitung Hand Held Druckmessger t 43 Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex 7 Fehler und Systemmeldungen Anzeige Bedeutung Abhilfe int iW bAt ES Batteriespannung schwach Funktion ist nur noch kurze Zeit gew hrleistet Neue Batterie einsetzten bAt Batterie ist leer Neue Batterie einsetzen Bei Netzger tebetrieb falsche Spannung Netzger t berpr fen austauschen SEnS Erro Es ist kein Sensor angesteckt Ger t ausschalten und Sensor anstecken Angesteckter Sensor oder Ger t ist defekt Mit evtl vorhandenem 2 Sensor das Ger t berpr fen Defekten Sensor bzw defektes Ger t zur Reparatur einschicken Loggerdaten werden ber die Schnittstelle ausgelesen Sobald bertragung beendet ist arbeitet Ger t wieder im normalen Messmodus keine Abhilfe notwendig Keine Anzeige bzw wirre Zeichen Ger t reagiert nicht auf Tastend ruck Batterie ist leer Neue Batterie einsetzen Netzger tebetrieb falsche Spannung Polung
51. nelle Messung gefiltert 100 Hz i P dEt Peak detection schnelle Messung ungefiltert 100 Hz t AVG 1 120 Zeit in Sekunden ber der die Mittelwertbildung errechnet wird oFF Mittelwertbildung deaktiviert P oFF 1 120 Auto Power Off Abschaltverz gerung in Minuten Wird keine Taste gedr ckt und findet kein Daten verkehr ber die Schnittstelle statt so schaltet sich das Ger t nach Ablauf dieser Zeit automatisch ab oFF Automatische Abschaltung deaktiviert Dauerbetrieb Adr 01 11 91 Basisadresse der Schnittstelle SEt Set Alarm Einstellung der Alarmfunktion AL AL on Alarm Sensor an mit Hupe 1 2 DIF no So Alarm Sensor an ohne Hupe OFF Keine Alarmfunktion AL Lo Sensor Min Min Alarm Grenze nicht wenn AL oFF Sensor Min 1 2 DIF AL Hi ist die untere Anzeigebereichs Grenze des ange steckten Sensors AL Hi AL Lo Max Alarm Grenze nicht wenn AL oFF Sensor Max 1 2 DIF Sensor Max ist die obere Anzeigebereichs Grenze des ange steckten Sensors SEt Set Logger Einstellung der Loggerfunktion if LoGG Func CYCL Cyclic Loggerfunktion zyklischer Logger Stor Store Loggerfunktion Einzelwertlogger 7 OFF Keine Loggerfunktion CYCL 11 3600 Zykluszeit in Sekunden bei zyklischem Logger 2 Lo Po on oFF Low Power Logger mit geringer Stromaufnahme H nur bei zyklischem Logger und langsamer Messung SEt Set Logger Einstellung der Echtzeituhr A CLOC CLOC HH MM Clock Einstellen der Uhrzeit Stunden Minute
52. nly will take a measurement at the point of time of the recording In between the recordings the mea suring shut s down This decreases the power consumption enor mously and therefore is recommended e g for long time recordings where no mains adapter is available Max number of measurements 9999 Cycle time 1 3600 seconds 1 h selec table from the configuration menu A measurement contains m Slow measuring rate rAtE SLo Sensor 1 instantaneous value at that data point Sensor 1 Min Peak Max Peak since last data point Sensor 2 instantaneous value at that data point Sensor 2 Min Peak Max Peak since last data point Instantaneous difference Sensor 1 Sensor 2 at that data point Min Peak Max Peak of difference Sensor 1 Sensor 2 Min Peak Max Peak since last data point m Fast measuring rate rAtE FASt P dEt Sensor 1 average since last data point Sensor 1 Min Peak Max Peak since last data point Sensor 2 average since last data point Sensor 2 Min Peak Max Peak since last data point Average difference Sensor 1 Sensor 2 since last data point Min Peak Max Peak of difference Sensor 1 Sensor 2 Min Peak Max Peak since last data point Only for 2 channel version CPH 6200 D Initiating Logging By pressing Store Quit for 2 seconds recording will be initiated After that the display shows St XXXX for a short time whenever a measurement is recorded XXXX is th
53. noch f r eine gewisse Zeit die Ger tefunktion gew hrleistet Wird in der oberen Anzeige bAt ange zeigt so ist die Batterie ganz verbraucht Batterie und Akku sind nur sachgem zu benutzen und ordnungsgem den aktuellen nationalen Vorschriften zu entsorgen Bei Lagerung des Ger tes ber 50 C muss die Batterie entnommen werden Wird das Ger t l ngere Zeit nicht benutzt sollte die Batterie der Akku herausgenommen werden m Netzger tebetrieb Beim Anschluss eines Netzger tes muss dessen Spannung zwischen 10 5 und 12 V DC liegen Keine berspannungen anlegen Einfache Netzger te k nnen eine zu hohe Leerlauf spannung haben dies kann zu einer Fehlfunktion bzw Zerst rung des Ger tes f hren Wir empfehlen daher unser Netzger t siehe aktuelle Preisliste CPH 6200 zu verwenden Vor dem Verbinden des Netzger tes mit dem Stromversor gungsnetz ist sicherzustellen dass die am Netzger t angege bene Betriebsspannung mit der Netzspannung bereinstimmt m Sensoren anstecken wechseln Nur Sensoren des Types CPT 6200 verwenden Mit anderen Sensoren kann es zur Zerst rung des Messger tes und des Sensors kommen Zum Sensorwechsel Ger t ausschalten Sensor vor dem Einschalten des Ger tes anstecken sonst wird er vom Ger t evtl nicht richtig erkannt Digitalger t und Sensor werden mittels eines separaten Verbindungskabels elektrisch miteinander verbunden F r den Sensorwechsel sollte bevorzugt der 7 polige Steckkon
54. nsure the device temperature has adjusted to the ambient temperature before trying to switch it on 4 If the instrument is to be connected to other devices e g via serial interface care must be taken when designing the equipment connec tions It is possible that internal wiring within the external device e g connection of GND to Earth may cause excessive voltages which could harm or destroy the instrument or other connected devices If the device is operated with a faulty mains power supply e g short circuit from mains voltage to output voltage this could result in dangerous voltages at the device e g at the sensor socket or serial interface 5 If there is any risk whatsoever involved in using it the device must be switched off immediately and marked accordingly to prevent re use Operator safety may be at risk if m There is visible damage to the device m The device is not working as specified mM The device has been stored under unsuitable conditions for an extended period of time If there is any doubt please return the device to the manufacturer for repair or maintenance 6 Customers must not attempt to alter or repair the device themselves Please return the device to the manufacturer for any repair or main tenance 7 Any operation not included in the following instructions or outside the specifications must not be attempted WIKA Operating Instructions Hand Held Pressure Indicator 5 Hand Held Pressure Indi
55. omentaner Wert zum Zeitpunkt des Speicherns Sensor 1 Min Peak Max Peak seit dem letzten Speichern Sensor 2 Momentaner Wert zum Zeitpunkt des Speicherns Sensor 2 Min Peak Max Peak seit dem letzten Speichern Differenz Sensor 1 Sensor 2 momentaner Wert zum Zeitpunkt des Speicherns Differenz Sensor 1 Sensor 2 Min Peak Max Peak seit dem letzten Speichern m Schnellen Messungen rAtE FASt P dEt Sensor 1 arithmetischer Mittelwert seit dem letzten Speichern Sensor 1 Min Peak Max Peak seit dem letzten Speichern Sensor 2 arithmetischer Mittelwert seit dem letzten Speichern Sensor 2 Min Peak Max Peak seit dem letzten Speichern Differenz Sensor 1 Sensor 2 arithmetischer Mittelwert seit dem letzten Speichern Differenz Sensor 1 Sensor 2 Min Peak Max Peak seit dem letzten Speichern Gilt nur f r 2 Kanal Version CPH 6200 D WIKA Betriebsanleitung Hand Held Druckmessger t 41 Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex 42 Loggeraufzeichnung starten Durch 2 Sekunden Dr cken der Taste Store Quit wird die Aufzeichnung gestartet Danach wird bei jeder Aufzeichnung kurz die Anzeige St XXXX angezeigt XXXX steht hierbei f r die Nummer des Datensatzes 1 9999 Falls der Loggerspeicher voll ist erscheint ie Aufzeichnung wird automatisch angehalten Labh Die Aufzeich ird aut isch hal u it A I L Bei der Low Power Logger Funktion Lo Po on sc
56. racy high noise immunity EMI and unstable measuring signals low power consumption 2 3 2 rAtE P dEt peak detection Measuring rate gt 100 Hz the value is displayed unfiltered Application with logger function Measuring of pressure spikes or fluctuating pressures with a resolution of lt 10 ms The cyclic logger function records the arithmetic mean value the highest and the lowest peak during the chosen time interval Higher power consumption measuring is sensitive to noise EMI 2 3 3 rAtE FASt fast filtered measuring Measuring rate gt 100 Hz but the value is filtered slightly higher noise immunity than P dEt small peaks will be filtered out apart from that identical behaviour to P dEt 2 4 Averaging function The averaging function acts on the displayed values LCD and serial interface It is completely independent of the averaging within the logger function please don t mix them up The averaging integrates the measured values during a chosen time interval and then calculates the average display value It is independent of the selected measuring rate slow fast peak detect Until sufficient values to calculate an average value have been collected dependant on selected averaging time the upper display shows the lower display shows a countdown During an active low power logging procedure the average is always deactivated WIKA Operating Instructions Hand Held Pressure Indicator 13 Ha
57. re Pressing Set Menu shows the difference between the measured values of Channel 1 and Channel 2 CH1 CH2 in the lower display Pressing it again will hide it only with the 2 channel version and when 2 sensors are connected WIKA Operating Instructions Hand Held Pressure Indicator 9 Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex Main Menu Stored data Recall of individually logged data and respective time stamp Func Stor configuration see Section 4 Configuration Unit Sea Level Measuring rate Power off interface address Alarm Min Max alarm visual with without sound Logger Switch from simple Hold to Logger function Single point values Stor or Cyclic CYCL System clock time day amp month year eee set parameter next store parameter amp quit ring shift appears only if data Func Stor is in the logger memory appears only if the logger memory is empty see Section 4 ae 10 WIKA Operating Instructions Hand Held Pressure Indicator 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex Menu Param _ Setting Meaning Menu gt Ao Vv SEt Set Configuration Generic settings ConF Unit mbar bar Un
58. rman text shall prevad Pruf und Zertdizerungsstetie ZELM Ex Suekgraben 56 D 38124 Braunschweig WIKA Operating Instructions Hand Held Pressure Indicator 23 Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex GBI 9 Calibration services DKD certificates other certificates If the instrument requires calibration we recommend returning it along with its associated sensors to the manufacturer Only the manufacturer is able to verify the instrument s basic settings and configuration and if necessary correct them 10 Specifications Input 1 for CPH 6200 CPH 6200 Ex 2 for CPH 6200 D Pressure range in bar 0 1 10 16 0 25 10 4 0 6 1 0 1 6 2 5 4 0 6 0 Overpressure safety in bar 1 15 2 2 4 5 10 10 17 35 Burst pressure in bar 2 2 24 24 48 6 12 12 20 5 42 Resolution in mbar 0 1 1 Pressure range in bar 10 16 25 40 60 100 160 250 400 600 1000 Overpressure safety in bar 35 80 50 80 120 200 320 500 800 1200 1500 Burst pressure in bar 42 96 250 400 550 800 1000 1200 1700 2400 3000 Resolution in bar 0 01 0 1 1 Type of pressure gauge absolute 0 25 up to 16 bar amp vacuum on request Accuracy of the 0 2 FS 1 digit at reference temperature of 20 C measuring chain Calibration factory calibration certificate optional DKD calibration certificate Display large LCD display for display of 2 four digit values and add
59. s Lo Po on OFF Low power logger with very low power consump tion only if cyclic logger with slow measuring rate SEt Set Clock Setting of real time clock CLOC CLOC HH MM Clock set time hours minutes dAtE TT MM Date set time day month YEAr YYYY Year set time year WIKA Operating Instructions Hand Held Pressure Indicator 11 Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex 12 I N j y j If there is existing data in the logger memory the menus parameters marked with cannot be accessed If these need to be adjusted the logger memory must first be cleared see Section 4 2 Configuration To change device settings press the Set Menu key for 2 seconds This will access the configuration menu main display SEt Pressing the Set Menu key again scrolls down the menus pressing the Tara key scrolls across to the associated para meters which can then be selected with the Tara key The parameters can be altered using the Min or Max keys Pressing the Set Menu key again saves the settings and returns you to the main configuration menu The Store Quit key exits the configuration and returns you to standard measuring mode 2 1 Unit Choice of pressure units Depending on the pressure range the pressure value can be displayed in any one of the following units mbar bar Pa kPa MPa mmHg or PSI 2 2 SL Sea level correction for abso
60. sprechende internationalen Normen orientiert Die Gew hrleistungszeit f r das Hand Held Messger t CPH 6200 betr gt 24 Monate nach den Allgemeinen Lieferbedingungen des ZVEI S mtliche Gew hrleistungsanspr che verfallen bei unsachgem er Handhabung bzw bei Nichtbeachtung der Betriebsleitungen oder bei dem Versuch das Ger t zu ffnen Au erdem weisen wir darauf hin dass der Inhalt dieser Betriebsanleitung nicht Teil einer fr heren oder bestehenden Vereinbarung Zusage oder Rechtsverh ltnisses ist oder diese ab ndern soll S mtliche Verpflichtun gen der WIKA Alexander Wiegand GmbH amp Co KG ergeben sich aus dem jeweiligen Kaufvertrag und den Allgemeinen Gesch ftsbedingungen der WIKA Alexander Wiegand GmbH amp Co KG WIKA ist ein eingetragenes Warenzeichen der WIKA Alexander Wiegand GmbH amp Co KG Firmen oder Produktnamen die in diesem Handbuch erw hnt werden sind eingetragene Warenzeichen dieser Hersteller Zumutbare nderungen aufgrund technischer Verbesserungen behalten wir uns vor Eine Vervielf ltigung dieses Handbuches oder Teilen davon ist untersagt Firmware Betriebsanleitung Versionsschl ssel V4 0 4 9 2005 Copyright WIKA Alexander Wiegand GmbH amp Co KG 1 1 Allgemeine Sicherheitshinweise Dieses Ger t ist gem den Sicherheitsbestimmungen f r elektronische Messger te gebaut und gepr ft Die Funktion und Betriebssicherheit des Ger tes kann nur dann gew hr WIKA Betriebs
61. t the sensor before turning the device back on otherwise the sensor may not be identified correctly The CPH 6200 and the pressure transmitter are connected using a discrete connecting cable When changing the pressure transmit ter always connect and disconnect at the transmitter end of the cable To connect the transmitter rotate the plug till it locates in the guide slot allowing it to plug in Then tighten the safety collar by screwing it lightly in a clockwise direction When connecting the cable to the CPH 6200 the connector might not locate properly in the socket In this instance you should try WIKA Operating Instructions Hand Held Pressure Indicator 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex holding the plug by the cable strain relief rather than by the GB connector housing If the plug is correctly located it will slide in smoothly To disconnect the sensor hold it by the plug to release the connector lock Do not pull the cable to release it For gauge sensors the pressure compensation vent hole is found at the top of the sensor housing This vent with integral membrane seal must be kept clear without fail m Maintenance advice Both the CPH 6200 and sensors are manufactured using solid state technology and contain no moving parts which could wear If the instrument housing has been opened the warranty becomes invalid If cleanin
62. takt am Sensor benutzt werden Zum Anschluss eines Sensors bitte die 7 polige Steckverbindung am Sensor gem der Orientierungsf hrung zusammenstecken und durch die berwurfh lse sichern berwurfh lse ohne gr eren Kraftaufwand in Uhrzeigersinn drehen Beim Anstecken des Kabels am Digitalger t kann es vorkommen dass der Stecker nicht richtig in die Buchse einrastet In diesem Fall den Stecker beim Anstecken nicht an Steckerh lse sondern am Knickschutz halten WIKA Betriebsanleitung Hand Held Druckmessger t 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Druckmessgerat CPH 6200 CPH 6200 D CPH 6200 Ex Stecker nicht verkantet anstecken Bei richtig angesetztem Stecker kann dieser ohne gr eren Kraftaufwand eingesteckt werden Beim Abstecken des Sensors nicht am Kabel ziehen sondern nur an der Steckerh lse Im hinteren Teil des Sensorgeh uses befindet sich bei ber druck bzw relativ Drucksensoren das Loch f r den Druck ausgleich diese ffnung mit integrierter Membrane muss unbedingt frei bleiben m Wartung Digitalger t und Sensoren enthalten keinerlei Verschlei teile so dass das ffnen der Ger te Geh use nicht erforderlich ist und f r die Auf rechterhaltung der Gew hrleistungsanspr che unbedingt unterbleiben sollte F r die Reinigung der Geh use Oberfl chen empfehlen wir ein weiches wenig fusselndes in Seifenwasser angefeuchtetes Tuch Wie f r Messmittel allgemein
63. tivated Measuring unit An arrow points to the chosen measuring unit SL indicates that the sea level function is activated Bon aA _ gt ONDA 1 5 Basic operation On turning the device on if the logger function is selected the integrated clock s time will be displayed briefly If a zero point adjustment has been carried out the display will indicate this by showing nuLL Corr After changing the battery the menu for setting the clock is activated automatically CLOC Check the clock and adjust if necessary see Section 2 00e 8098 8 WIKA Operating Instructions Hand Held Pressure Indicator 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex On Off key Set Menu Enter Configuration Menu press for 2 sec Tara Activate tare function zero point adjustment Store Quit Activate hold function or logger function see Section 4 Min Max Display the respective min max memory value in lower display ARON Max Function Pressing Max shows the maximum measured value recorded Pressing it again hides it To clear the max memory press the Max key for gt 2 seconds Min Function Pressing Min shows the minimum measured value recorded Pressing it again hides it To clear the min memory press the Min key for gt 2 seconds Hold Function By pressing Store Quit the instantaneous measured value will be shown
64. ured by compli ance with EN 50 014 1997 A1 A2 EN 50020 1994 If the sign X is placed after the certificate number it indicates that the equipment is subject to special conditions for safe use specified in the schedule to this certificate This EC type examination Certificate relates only to the design examination and tests of the specified equipment or protective system in accordance to the Directive 94 9 EC Further re quirements of the Directive apply to the manufacturing process and supply of this equipment or protective system These are not covered by this Certificate The marking of the equipment shall include the following amp 2G EExibuic T4 Zertifizierungsstelle ZELM Ex Braunschweig August 04 2003 A a Se nma Dipl Ing Hara Zeim Sheet 1 2 EC type exam naton Certficates without signature and stamp are not vabd The certificates may onty be circulated without alteration Extracts or alteratons are subject to approval by the Pr f und Zertfizierungsstelie ZELM Ex Thus Engish version 15 based on the German text In the case of dspute the German text shall prevad Prut und Zertfizerungsstelle ZELM Ex Sekgraben 56 D 38124 Braunschweig WIKA Operating Instructions Hand Held Pressure Indicator 2386816 1 2 08 2005 GB D 2386816 1 2 08 2005 GB D Hand Held Pressure Indicator CPH 6200 CPH 6200 D CPH 6200 Ex Pr f und Zertifizierungsstelle ZELM amp x SCHEDULE EC TYPE EXAMINATION CERTIFICATE Z