1.    Mosys    Bedienungsanleitung    Operating Instructions    EN    Technik f  r M  bel Hett                                                                                                                                                                         Bedienungsanleitung   Original                                                                   1 Einleitung 4  2 Einbauerkl  rung 5  3 Sicherheitshinweise 6  3 1 Symbolerkl  rung 6  3 2 Brandgefahr 6  3 3 Gefahr f  r Kinder 6  3 4 Gefahr durch Elektrizit  t 6  3 5 Sachsch  den 7  3 6 Quetschgefahr 7  4 Hinweise zum Betrieb 7  4 1 Bestimmungsgem    e Verwendung 7  4 2 Vorhersehbare Fehlanwendung 8  4 3 Entsorgung 8  5 Technische Daten 8  6 Elektrischer Anschluss 9  7 Bedienung 9  7 1 Aussetzbetrieb 9  7 2 Fernbedienung 10  7 2 1 Fernbedienung Kabel 10  7 2 2 Fernbedienung Funk 10  73 Netzteile 11  8 Pflege und Reinigung 11  9 Service 11          1 Einleitung    Liebe Kundin  lieber Kunde    wir gratulieren Ihnen  dass Sie sich f  r ein Qualit  tserzeugnis der Firma Hettich Franke  GmbH  amp  Co  KG entschieden haben  Diese Anleitung ist vor Einbau und Inbetriebnahme des  Produktes sorgf  ltig zu lesen  damit die Beachtung aller Sicherheitshinweise gew  hrleistet  ist und Sie alle M  glichkeiten des Mosys Antriebssystems richtig nutzen k  nnen  Dieses  Produkt wurde mit modernen Fertigungsverfahren und umfangreichen Qualit  tssicherungs   ma  nahmen hergestellt  Hettich Franke arbeitet st  ndig an der Weiterentwicklung s
2.   Alternatively  Duration of continuous operation one minute  then it is essential to ensure  that the drive unit is not operated for at least 9 minutes     17    7 2 Hand sets    7 2 1 Hand set cable  see illustration 2     Start up  Insert the power plug into the power socket     A  raise head section Press the left side of the top key  A  to raise the head section  B  lower head section Press the right side of the top key  B  to lower the head section  C  lower foot section Press the right side of the bottom key  C  to lower the foot  section  D  raise foot section Press the left side of the bottom key  D  to raise the foot section    When using the Mosys Standard system  the upper end position is limited via an electrical  limit switch  If the lower foot section or lower foot section key is activated  while the  slatted frame is in zero position  an anti trap protection function is activated  You will  hear a clicking sound  This clicking sound is normal and is not an indication that the drive  unit is defective        7 2 2 RF remote control  see illustration 3 4 5     Start up      Remove protective plastic wrap between battery contacts at the back of the hand set       Insert the power plug into the power socket      The drive goes into the    learn mode  for approximately 30 seconds  green LED on the  controller flashes  see illustration 10    I        During the learning period  press any button on the remote control for approximately  5 seconds      The radio system
3.  24V DC  Schutzart  IP 20  Verstellzeit f  r max  Hub      ca 9 55  Max  Drehmoment  250 Nm  Max  Dauerbetrieb  2 min  Drehwinkel  ca  70            232 x 178 x 110 mm  per Fernbedienung    Ma  e  L  nge x Breite x H  he    Schaltm  glichkeiten                       Frequenzbereich bei Funkausf  hrung  433 MHz  Batterien  Fernbedienung Funk   2 mal LR6 1 5V  Betriebsstrom  12 mA  Umgebungs   Lagerbedingungen   Raumtemperatur  von  10  C bis  40  C       Relative Luftfeuchte  von 30   bis 75           bei bestimmungsgem    er Verwendung    arithmetisches Mittel von Heben und Senken    8    6 Elektrischer Anschluss    Das Antriebssystem ist f  r eine Wechselspannung ausgelegt  siehe Abschnitt 5    Technische  Daten    Entsprechend der Leistungsaufnahme  siehe Typenschild  ist bauseitig eine  Schukosteckdose oder eine den einschl  gigen und oder l  nderspezifischen Vorschriften  entsprechende Schutzvorrichtung  nur durch Elektrofachkr  fte  vorzusehen     A GEFAHR    Vor dem Anschluss des Antriebssystems sind unter anderem die   bereinstimmung von Stromart  und Netzspannung mit den Angaben auf dem Typenschild des Netzteiles zu   berpr  fen     Verlegen Sie das Kabel ordnungsgem      siehe Abschnitt 3 4    Gefahr durch Elektrizit  t    Stecken Sie den Netzstecker nur in eine passende Steckdose     Achten Sie auf sachgem    e Kabelf  hrung des Netzanschlusses  des Steuerkabels zur  Fernbedienung und des Verbindungskabels zum zweiten Antriebssystem     7 Bedienung    V ACHTUNG    E
4.  and mechanical overloads and continuous operation of the  drive unit lasting more than two minutes  Do not stand on the slatted bed frame  The  individual slats are not designed to carry this amount of weight  Do not sit on the raised  head or foot section  The adjustment elements are not designed to hold such loads  Only  use the slatted frame for its intended purpose and do not overload it     3 6 Crushing hazard    With the aid of an audible free running mechanism and an intelligent motor cut off  function  the Classic system features a double anti trap protection in every position  Due  to the application of an audible free running mechanism  the Standard version also features  anti trap protection  However  the user must ensure that no persons  pets or objects are in  the danger area during operation  Children are not allowed to operate the drive unit     4 Operating information  see figure 1     4 1 Appropriate use    The system is only allowed to be used in beds  slatted bed frames and or box spring beds  for the purpose of raising and lowering the back and foot sections     4 2 Foreseeable misuse    The system is not approved for use in healthcare areas and facilities  e g  hospital  rest or  retirement home  nursing home etc       gt  In damp or extremely humid environments or outdoors     Without a bed frame  directly on the floor    gt  Asa lifting device for heavy loads etc    gt  For all other forms of application that are not in accordance with correct use    I
5.  im gesamten Europ  ischen Wirtschaftsbereich eingesetzt werden   Class   System     7 3 Netzteile  s  Abb  8 9     Bei Verwendung des Netzteiles mit NAS  Notabsenkungsfunktion  ist die Batterie im  Batteriefach anzuschlie  en     Die 9 V Blockbatterie dient nur zur    Notabsenkung  des Systems  d  h  im Falle eines Strom   ausfalls oder Systemfehlers besteht die M  glichkeit des Verstellens in die Liegeposition        HINWEIS    Die Batterie dient nicht zum Hochstellen des Systems     8 Pflege und Reinigung    Eine Gew  hr f  r eine einwandfreie Funktion und Betriebssicherheit kann nur bei sach   gem    er Handhabung des Antriebssystems sowie der Beachtung der Hinweise in der  Betriebsanleitung und der entsprechenden Vorschriften zugesichert werden     A GEFAHR    Gefahr durch elektrischen Strom   Trennen Sie das Antriebssystem vom elektrischen Netz durch Ziehen des Netzsteckers vor  Ausf  hrung der Pflege  und Reinigungsarbeiten  spannungsfrei schalten       gt  Bringen Sie das Antriebssystem niemals mit Wasser in Ber  hrung  Das eventuelle  Eindringen von Wasser in die elektrischen Bauteile kann den ordnungsgem    en Betrieb  und den Schutz gegen elektrischen Stromschlag des Ger  tes beeintr  chtigen     Es sind handels  bliche Reinigungs  und Pflegemittel f  r Kunststoffe  Polyamid 6  und f  r  verzinkte St  hle unter Beachtung der Herstellerangaben zu benutzen     Verwenden Sie zum Reinigen keinesfalls scheuernde  chemisch aggressive oder   tzende  Reinigungsmittel bzw  
6.  is ready for operation  The green LED on the controller  see illustration  10    I   lights up during the adjustment       NOTE    Put the drive units one after another into operation and not several at the same time    If the encoding process has not been completed successfully  repeat the start up after  about 2 minutes    After a current interruption or power failure there is no need to encode the system once  again as it maintains the previous encoding     Additional radio control function  see illustration 3    G  raise head section foot section  F  lower head section foot section    V CAUTION    Use the RF remote control only when the bed you want to adjust is within eyeshot   Please note that other equipment that works within a frequency range of 433 MHz  can interfere with each other     Remote control battery insertion exchange  see illustration 3 4 5    1  Remove the battery compartment cover  see illustration 4  E   on the back of the  remote control    2  Insert the batteries into the battery compartment  Ensure that the polarity is correct  when inserting batteries  see image in the battery compartment     3  Close the battery compartment cover back and press any button on the remote control   If the batteries are inserted correctly  the control lamp on the controller  see illustration  10    I   should light up at each press of a button        18    If the remote control is not used over a longer period of time  the batteries should be  removed in order to avoi
7.  neu einzulernen  da es den urspr  nglichen Betriebszustand  Codierung  beibeh  lt     v    vv    v    v    Zusatzfunktion bei Funk  siehe Abb  3    G  Kopfteil Fu  teil heben  F  Kopfteil Fu  teil senken    V ACHTUNG    Benutzen Sie die Fernbedienung Funk nur dann  wenn sich das zu verstellende Bett  in Sichtweite befindet    Bitte beachten Sie  dass andere Ger  te  die auch im Frequenzbereich von 433 MHz  arbeiten  sich gegenseitig beeinflussen k  nnen     Einlegen Wechseln der Batterie in der Fernbedienung  s  Abb  3 4 5    1  Entfernen Sie den Batteriefachdeckel  siehe Abb  4    E   auf der R  ckseite  der Fernbedienung    2  Legen Sie die Batterien in das Batteriefach ein  Achten Sie dabei auf die richtige  Polarit  t  siehe Abbildung im Batteriefach     3  Schlie  en Sie den Batteriefachdeckel und dr  cken Sie eine beliebige Taste auf der  Fernbedienung  Wenn die Batterie richtig eingesetzt ist  muss bei jedem Tastendruck  die Kontrollleuchte auf der Steuerung Funk  siehe Abb  10    I   leuchten     Wenn Sie die Fernbedienung f  r l  ngere Zeit nicht benutzen  nehmen Sie bitte die Batterie  heraus  um eine Besch  digung der Fernbedienung durch eine evtl  auslaufende Batterie zu  vermeiden     Bei Verlust der Fernbedienung Funk oder im Falle eines Stromausfalls  nur bei Netzteil mit  NAS Funktion  siehe 7 3  besteht die M  glichkeit   ber die Reset Taste  siehe Abb  10    H    auf der Steuerung Funk das System in die Liegeposition zu verstellen     Dieses Funksystem darf
8.  safe use of the appli   ance and the potential hazards that may result from  improper use  Children are not allowed to play with  the appliance  Children are not allowed to perform  cleaning and user maintenance operations without  supervision     3 4 Electrical hazard    Do not open the electrical drive unit under any cir   cumstances  Ensure that the electric cable is safely  routed  If necessary  use additional protective tubing  or insulated spacers  Avoid crimping and abrasion of  the cables  Ensure that the cable cannot be trodden    on and that nothing can ride over it  Ensure that  there are no loose cables on the floor or in the air  where people walk  This will help to prevent tripping  hazards  Do not start up the drive unit if the mains  plug appears to be defect or the drive unit shows  other visible signs of damage     Do not exchange damaged cable or mains plugs your   self  Contact a specialist workshop for such repairs   Only qualified personnel are allowed to perform work  on the power connection cable  Remove the mains  plug before moving the slatted frame from one place  to another        NOTE   The drive system may only be used in combination  with the supplied power supply units  The drive sys   tem is only to be supplied with a safety low voltage  in compliance with the respective specification on  the appliance     3 5 Material damages    The drive unit is only allowed to be used in dry rooms  Protect the drive unit against  dampness  Avoid electrical
9. 2   EN 62233 2008   EN 300 220 2 V2 3 1EN 301 489 1 V1 9 2EN 301 489 3 V1 4 1EN 50371 2002  EN 62479 2010EN 60950 1 2006    This EC declaration loses its validity if the product is converted or modified without the  respective authorisation     Note  The incomplete Mosys type machine can only be started up after it has been    determined that the machine  in which the  Mosys  is to be installed  is in accordance with  the regulations of the Machinery Directive     72336 Balingen  date 1 08 2013          Genefal Manager  Richard Weinzierl    3 Safety information  3 1 Symbol explanation    N DANGER in general    A DANGER of electric shock  V CAUTION       NOTE  important information     3 2 Fire hazard    Observe the relevant regulations concerning fire safety measures  In the event of fire  the  drive unit must be disconnected from the electrical mains by removing the plug  Therefore   the mains plug must be accessible at all times during operation  so that it can be easily  and quickly removed from the socket in cases of emergency     3 3 Danger for children    A Keep packaging and fitting material out of your  children s reach  Among other things  these materials  pose a danger of asphyxiation or danger of swal   lowing small parts     This appliance can be used by children aged 8 years  and over and by persons with reduced physical  sen   sory or mental capabilities or lack of experience and  knowledge  provided that they are given supervision  or instruction concerning the
10. 2 Einbauerkl  rung    Gem     Anhang II  Teil 1 Abschnitt B der Richtlinie 2006 42 EG des Europ  ischen Parlaments  und des Rates vom 17 05 2006   ber Maschinen und zur   nderung der Richtlinie 95 16 EG   Neufassung     im Namen der Firma  Hettich Franke GmbH  amp  Co  KG    erkl  rt die unterzeichnende Person   Das elektromechanische Antriebssystem Mosys f  r elektrisch verstellbare Lattenroste  dient zur elektrischen Verstellung des Kopf  bzw  Fu  teils     Die Typenbezeichnung ist  Mosys    Im Rahmen der Konformit  tsbewertung sind die erforderlichen speziellen technischen  Unterlagen erstellt und hinterlegt  Den einzelstaatlichen Stellen k  nnen  bei begr  ndeten  Verlangen  die spezielle technische Unterlagen in Papier  oder elektronischer Ausf  hrung    berlassen werden  Die speziellen technischen Unterlagen k  nnen angefordert werden bei     Richard Weinzierl  Hettich Franke GmbH  amp  Co  KG  72336 Balingen   Name  Anschrift        Das Produkt entspricht au  erdem den folgenden europ  ischen Richtlinien     Maschinenrichtlinie 2006 42 EG  RoHs Richtlinie 2011 65 EG  EMV Richtlinie 2004 108 EG  R amp TTE Richtlinie 1999 5 EG    Folgende harmonisierte Normen wurden angewendet     EN 55014 1 2006 A1 2009 A2 2011   EN 55014 2 1997 A1 2001 A2 2008   EN 61000 3 2   EN 61000 3 3   EN 60335 1 2012   EN 62233 2008   EN 300 220 2 V2 3 1EN 301 489 1 V1 9 2EN 301 489 3 V1 4 1EN 50371 2002  EN 62479 2010EN 60950 1 2006    Diese EG Erkl  rung verliert ihre G  ltigkeit  wenn das Pro
11. aufsichtigung durchgef  hrt werden     3 4 Gefahr durch Elektrizit  t    IN   ffnen Sie keinesfalls den elektrischen Antrieb   Stellen Sie die gesch  tzte Verlegung der Kabel sicher   Verwenden Sie ggf  zus  tzliche Schutzschl  uche oder  isolierte Abstandshalter  Vermeiden Sie Quetsch  und  Scheuerstellen an Kabeln  Schlie  en Sie die   berfahr   oder Drauftretm  glichkeiten der Kabel aus     Stellen Sie sicher  dass sich im Gehbereich auf dem  Boden und in der Luft keine losen Kabel befinden   Damit vermeiden Sie Stolperfallen  Nehmen Sie das  Antriebssystem nicht in Betrieb  wenn der Netzstecker  defekt ist oder das Antriebssystem andere sichtbare  Sch  den aufweist  Tauschen Sie besch  digte Kabel  oder Netzstecker nicht selber aus  sondern wen    den Sie sich an eine Fachwerkstatt  Arbeiten an der  Netzanschlussleitung d  rfen nur durch Fachpersonal  durchgef  hrt werden  Ziehen Sie den Netzstecker vor  einer Ortsver  nderung des Lattenrostes        HINWEIS   Das Antriebsystem ist nur mit den mitgelieferten  Netzteilen zu benutzen    Das Antriebsystem ist nur mit der Sicherheitsklein   spannung entsprechend der Kennzeichnung auf dem  Ger  t zu versorgen     3 5 Sachsch  den    Das Antriebssystem darf nur in trockenen R  umen benutzt werden  Sch  tzen Sie das  Antriebssystem vor Feuchtigkeit  Vermeiden Sie elektrische und mechanische   berlastung  sowie Dauerbetrieb des Antriebsystems von mehr als zwei Minuten  Stellen Sie sich nicht  auf den Lattenrost  Die einzelnen Fed
12. contact with battery  acid  immediately rinse the affected areas with lots of clear water and seek medical  attention right away    5 Technical data                                     Mains voltage  230 V AC  Power consumption   70 W  Motor voltage  24V DC  Protection type  IP 20  Adjustment time for max  lift     approx  9 5 s  Max  torque  250 Nm  Max  continuous operation  2 min  Rotation angle  approx  70    Dimensions  length x width x height   232 x 178 x 110 mm  Control options  Hand set  Frequency range of radio control  433 MHz  Batteries  radio remote control   2 times LR6 1 5V       Operating current  12 mA  Ambient   storage conditions  Room temperature    Relative humidity           from  10  C to  40  C  from 30   to 75               16      during correct use    arithmetic average of raising and lowering    6 Electrical connection    The drive unit is designed for alternating current voltage  see section 5  Technical data     In compliance with the power consumption  see type plate   the customer must ensure  the provision of a shockproof socket or a respective safety device  installed by professional  electricians  in accordance with the relevant and or country specific regulations     A DANGER    Danger due to electrical current  The power connection cable of this device cannot be replaced   If the cable should be damaged  the device has to be scrapped  Before connecting the drive unit   it is essential to perform certain safety checks  among which is the co
13. d possible damage that may otherwise be caused by leaking  batteries     If you lose the RF remote control or in case of a power failure  only if the bed uses the  power supply unit SMPS NAS  see 7 3  the bed can be returned into the lying position  by pressing the reset button  see illustration 10  H   at the control unit     This radio system is allowed to be used within the entire European economic region   Class   system     7 3 Power supply units  see illustration 8 9     When using the SMPS NAS  emergency lowering   the battery has to be connected in the  battery compartment     The 9 V block battery only serves the purpose of an    emergency lowering    of the system   i e  if a power outage system error should occur  it is still possible to adjust to a lying  position        NOTE    The battery is not intended to be used to raise the system     8 Cleaning and care    A guarantee for a perfect working condition and battery reliability can only be provided  when the drive unit is used correctly and the instructions and respective regulations  specified in the operating manual are observed     A DANGER    Danger due to electrical current   Completely disconnect the drive unit from the electrical network by removing the power  plug from the mains before performing care and cleaning tasks  ensure zero potential      gt  Never bring the drive unit into contact with water  Possible infiltration of water and  contact with electrical components can negatively influence the cor
14. dukt ohne Zustimmung umgebaut  oder ver  ndert wird     Hinweis  Die unvollst  ndige Maschine vom Typ Mosys darf erst dann in Betrieb genommen  werden  wenn festgestellt wurde  dass die Maschine in die    Mosys  eingebaut werden soll   den Bestimmungen der Maschinenrichtlinie entspricht     72336 Balingen  den 01 08 2013          Gesch  ftsf  hrer  Richard Weinzierl          3 Sicherheitshinweise  3 1 Symbolerklarung    A GEFAHR allgemein  A GEFAHR durch elektrischen Stromschlag    V ACHTUNG      HINWEIS  wichtige Information     3 2 Brandgefahr    Beachten Sie die einschl  gigen Vorschriften bez  glich des Brandschutzes  Im Brandfall ist  das Antriebssystem durch den Netzstecker von dem elektrischen Netz zu trennen  Der  Netzstecker muss daher im Betrieb jederzeit zug  nglich sein  um ihn im Notfall schnell  aus der Steckdose ziehen zu k  nnen     3 3 Gefahr f  r Kinder    IN Halten Sie Kinder von Verpackungs  und Monta   gematerial fern  Es besteht u  a  Erstickungsgefahr  und Gefahr durch Verschlucken von Kleinteilen     Dieses Ger  t kann von Kindern ab 8 Jahren und  dar  ber sowie von Personen mit verringerten physi   schen  sensorischen oder mentalen F  higkeiten oder  Mangel an Erfahrung und Wissen benutzt werden   wenn sie beaufsichtigt oder bez  glich des sicheren  Gebrauchs des Ger  tes unterwiesen wurden und die  daraus resultierenden Gefahren verstehen  Kinder  d  rfen nicht mit dem Ger  t spielen  Reinigung und  Benutzer Wartung d  rfen nicht von Kindern ohne  Be
15. einer  Produkte    nderungen des Lieferumfanges in Form  Technik und Ausstattung in Abweichung  zu dieser Anleitung behalten wir uns vor  Aus Angaben und Abbildungen dieser Anleitung  k  nnen deshalb keine Anspr  che abgeleitet werden  Des Weiteren besteht keine Verpflichtung an  bereits ausgelieferten Ger  ten   nderungen vorzunehmen  Das Nichtbeachten dieser Bedienungs   anleitung f  hrt zum Verlust des Gew  hrleistungsanspruchs     Haftungsausschluss  Die Verwendung des Systems ist nur in Betten  Lattenrosten und oder Spiralnetzrahmen zul  ssig  zum Heben und Senken des R  cken  und des FuBteiles     bestimmungsgem    er Gebrauch       Das System ist nicht zul  ssig      f  r den Gebrauch in medizinischen Bereichen  z  B  Krankenhaus  Alten  und Pflegeheimen  etc       als Hebevorrichtung f  r Lasten etc     gt  f  r alle anderen Anwendungen die keinen bestimmungsgem    en Gebrauch darstellen    Zuwiderhandlungen f  hren zum Ausschluss jeglicher Haftung der Firma Hettich Franke   Bei einem Eingriff in das System durch Personen  die nicht von Hettich Franke dazu  autorisiert sind  erl  schen ebenfalls s  mtliche Gew  hrleistungs  und Haftungsanspr  che  bez  glich des kompletten Antriebssystems  Dies gilt auch f  r den Fall des nicht ordnungs   gem    en Gebrauchs  der unsachgem    en Behandlung und falschen Bedienung oder wenn  Hettich Franke etwaige Sch  den aus anderen Gr  nden nicht zu vertreten hat     Copyright 2013  Hettich Franke GmbH  amp  Co  KG  Balingen    4    
16. erleisten sind f  r dieses Gewicht nicht ausgelegt   Setzen Sie sich nicht auf das hochgestellte Kopf  bzw  Fu  teil  Die Verstellelemente   sind f  r diese Belastung nicht ausgelegt  Verwenden Sie den Lattenrost nur f  r seinen  vorgesehenen Verwendungszweck und   berlasten Sie ihn nicht     3 6 Quetschgefahr    Mit einem mechanisch akustischen Freilauf sowie einer intelligenten Motorabschaltung verf  gt  das Classic System   ber einen doppelten Einklemmschutz in jeder Position  Auch die Standard  Version besitzt auf Grund des mechanisch akustischen Freilaufs einen Einklemmschutz  Der  Anwender hat jedoch zu beachten  dass beim Bedienen keine Personen  Haustiere und Gegen   st  nde im Gefahrenbereich sind     4 Hinweise zum Betrieb  s  Abb  1     4 1 Bestimmungsgem    e Verwendung    Die Verwendung des Systems ist nur in Betten  Lattenrosten und oder Spiralnetzrahmen   zum Heben und Senken des R  cken  und FuBteils zul  ssig     4 2 Vorhersehbare Fehlanwendung    Das System ist nicht zul  ssig f  r den Einsatz in medizinischen Bereichen   z  B  Krankenhaus  Alten  oder Pflegeheimen  etc         in feuchter Umgebung  oder im Freien      ohne Bettgestell  direkt auf dem Boden      als Hebevorrichtung von Lasten  etc       f  r alle anderen Anwendungen  die keine bestimmungsgem    e Verwendung darstellen    Zuwiderhandlungen f  hren zum Ausschluss jeglicher Haftung des Herstellers  Bei einem  Eingriff in das System durch Personen  die nicht von Hettich Franke dazu autorisiert  
17. harte Reinigungsb  rsten  Das Antriebssystem ist weitestgehend  wartungsfrei     9 Service    Service und Wartung d  rfen nur von entsprechend geschultem Personal durchgef  hrt  werden  Bei Reparatur und Beschaffung von Ersatzteilen und Zubeh  r wenden Sie sich  bitte an Ihren Lieferanten     Weitere Sprachversionen der Bedienungsanleitung finden Sie auf unserer Homepage  unter www hettich com  Produkte   Verstellsysteme f  r Sitz  und Liegem  bel   Mediathek     Operating Instructions   Original                                                                      1 Introduction 12  2 Declaration of Incorporation 13  3 Safety information 14  3 1 Symbol explanation 14  3 2 Fire hazard 14  3 3 Danger for children 14  3 4 Electrical hazard 14  3 5 Material damages 15  3 6 Crushing hazard 15  4 Operating information 15  4 1 Appropriate use 15  4 2 Foreseeable misuse 16  4 3 Disposal 16  5 Technical data 16  6 Electrical connection 17  7 Operation 17  7 1 Intermittent duty 17  72 Hand sets 18  7 2 1 Hand set Cable 18  7 2 2 RF remote control 18  7 3 Power supply units 19  8 Cleaning and care 19  9 Service 19       1 Introduction    Dear Customer    we congratulate you for your wise decision to buy a quality product manufactured by  Hettich Franke GmbH  amp  Co  KG  In order to ensure that all safety information is observed  and that you are able to use all options provided by the Mosys drive unit to your full  advantage  please read this manual thoroughly before installing and sta
18. ken Sie die Taste rechts unten  C   um das Fu  teil zu senken   D  Fu  teil heben  Dr  cken Sie die Taste links unten  D   um das Fu  teil zu heben     Bei Verwendung des Systems Mosys Standard wird die obere Endstellung durch einen  elektrischen Endschalter begrenzt  Wenn die Taste    Kopfteil senken  bzw     Fu  teil senken   bet  tigt wird  w  hrend sich der Lattenrost in der Nullposition befindet  wird der Einklemm   schutz aktiviert  Sie h  ren ein Klackger  usch  Dieses Klackger  usch ist normal und ist kein  Hinweis f  r einen Defekt des Antriebssystems     7 2 2 Fernbedienung Funk  s  Abb  3 4 5     Inbetriebnahme   Entfernen Sie die Schutzfolie zwischen den Batteriekontakten auf der R  ckseite   der Fernbedienung   Stecken Sie den Netzstecker in die Steckdose   Der Antrieb befindet sich nun f  r ca  30 Sekunden im    Lernmodus     gr  ne LED auf der  Steuerung blinkt  siehe Abb  10  I     Dr  cken Sie w  hrend des Lernzeitraums f  r ca  5 Sekunden eine beliebige Taste der  Fernbedienung   Das Funksystem ist betriebsbereit  Die gr  ne LED auf der Steuerung Funk    siehe Abb  10       leuchtet w  hrend der Verstellung       HINWEIS    Nehmen Sie die Antriebssysteme nacheinander und nicht mehrere Systeme   gleichzeitig in Betrieb    Wenn der Codiervorgang nicht erfolgreich abgeschlossen werden konnte    wiederholen Sie die Inbetriebnahme nach einer Wartezeit von ca  2 Minuten erneut   Nach Stromunterbrechung  bzw  einem Stromausfall ist es nicht erforderlich das System 
19. mpliance of the type of  current and the mains voltage with the specifications on the type plate of the power supply unit     Route the cable safely and correctly  see section 3 4  Electrical hazard    Insert the power plug into the power socket     Ensure that the mains cable  the hand set cable and the connecting cable to the second  drive unit are appropriately routed     7 Operation    V CAUTION    Potential safety hazards or risk of damage to the product can occur if the drive unit is  operated  without respective supervision  by young children or persons with invalidities  or frail constitutions  The drive unit is only allowed to be used by adults        NOTE    Before starting up the system  the user must firstly check to see if the adjustable parts  are still secured by some sort of transport securing aid  e g  duct or Velcro tape   Release  the transport securing aid  The head and foot section can be comfortably lowered and or  raised to the desired position in a continuously variable mode     V CAUTION    Ensure that no persons  pets and objects are in the danger area during operation   see 3 6 crushing hazard      7 1 Intermittent duty    V CAUTION    Damage to the drive due to overloading     gt  Only operate the drive unit in intermittent duty  ID 2 min 18min      Avoid electrical or mechanical overloading    Example  Maximum duration of continuous operation two minutes  then it is essential to  ensure that the drive unit is not operated for at least 18 minutes  
20. n cases of non compliance  the manufacturer will accept no responsibility whatsoever    If an intervention is performed on the system by a person or persons not authorised to do  so by Hettich Franke  all warranty and liability claims concerning the complete drive unit  will also be terminated  This also applies to cases of incorrect assembly and dismantling   incorrect use  incorrect treatment and incorrect operation  or if any other damages should  exist for which Hettich Franke has no responsibility        4 3 Disposal       When disposing of a drive unit that is no longer in working order  please observe the  applied environmental protection regulations of the respective country      Batteries must be disposed of in accordance with the Ordinance on the Disposal of old  Batteries      This product is not subject to the EU Directive 2002 96 EC  WEEE  and its  supplementation EU Directive 2003 108 EC    V ATTENTION     gt  Never recharge the batteries  Explosion hazard     gt  Keep the batteries out of children s reach  do not throw into fire  do not short circuit or  take batteries apart      If necessary  clean the battery and appliance contacts before inserting      Remove exhausted batteries from the appliance immediately  Increased risk of leakage       Do not expose the batteries to any extreme conditions  e g  by placing on top of heaters  or by exposing to direct sunlight  Increased risk of leakage       Avoid contact with skin  eyes and mucous membranes  In case of 
21. rect operation and  seriously impair the protection against electric shock     Customary cleaning and care products for plastic  polyamide 6  and for galvanised steels  are to be used under observation of the respective manufacturers    instructions    Under no circumstances should you use abrasive  chemically aggressive or corrosive  cleaning products or hard cleaning brushes  The drive unit is practically maintenance free     9 Service    Service and maintenance operations are only allowed to be performed by respectively  trained staff  If you need repair  spare parts and accessories  please contact your supplier     Other language versions of the operating instructions can be found under  www hettich com  Products   Adjustable systems for seating and beds   Media centre      19          A    NM       Technik f  r M  bel Hetti    
22. rting up the product   This product was made with the aid of state of the art manufacturing methods and the  application of comprehensive quality assurance measures  The Hettich Franke company  works continuously on the further development of its products  We reserve the right to  perform changes to the scope of supply  which may deviate from this manual with regard  to shape  technology and accoutrements  Therefore  no claims can be made concerning  possible deviating specifications and images contained in this manual  Furthermore    we accept no obligation to perform changes to devices that have already been supplied   Non observance of this instruction manual can lead to a loss of the warranty claim     Disclaimer  The system is only allowed to be used in beds  slatted bed frames and or box spring beds  for the purpose of raising and lowering the back and foot sections   Appropriate use         The system is not approved for use   gt  in healthcare areas and facilities  e g  hospital  rest home  nursing home etc     gt  asa lifting device for heavy loads etc    gt  for all other forms of use that are not in line with the appropriate application    In cases of non compliance  Hettich Franke will accept no liability whatsoever  If an inter   vention is performed on the system by a person or persons not authorised to do so by  Hettich Franke  all warranty and liability claims concerning the complete drive unit will also  be terminated  This also applies to cases of incorrect 
23. s k  nnen Unfallgefahren entstehen und das Produkt Schaden nehmen  wenn das Antriebs   system durch kleine Kinder oder gebrechliche Personen ohne Aufsicht benutzt wird   Das Antriebssystem darf nur von Erwachsenen benutzt werden       HINWEIS    Der Anwender hat vor Inbetriebnahme des Systems zu pr  fen  ob die verstellbaren Teile  mit einer Transportsicherung  z  B  Klebe  oder Klettband  gesichert sind  L  sen Sie die  Transportsicherung    Durch Bet  tigung der Fernbedienung l  sst sich das Kopf  und Fu  teil stufenlos in die  gew  nschte Position bringen     V ACHTUNG    Achten Sie darauf  dass beim Bedienen keine Personen  Haustiere und Gegenst  nde im  Gefahrenbereich sind  siehe 3 6 Quetschgefahr      7 1 Aussetzbetrieb    V ACHTUNG    Besch  digungen des Antriebs durch   berlastung      gt  Betreiben Sie das Antriebssystem nur im Aussetzbetrieb  AB 2 min 18min    gt  Vermeiden Sie die elektrische und mechanische   berlastung    Beispiel  Maximaler Dauerbetrieb zwei Minuten  danach unbedingt eine Pause von  mindestens 18 Minuten einhalten     Alternativ  Dauerbetrieb eine Minute  danach unbedingt eine Pause von mindestens  neun Minuten einhalten     7 2 Fernbedienung    7 2 1 Fernbedienung Kabel  s  Abb  2     Inbetriebnahme  Stecken Sie den Netzstecker in die Steckdose     A  Kopfteil heben  Driicken Sie die Taste links oben  A   um das Kopfteil zu heben   B  Kopfteil senken  Dr  cken Sie die Taste rechts oben  B   um das Kopfteil zu senken   C  Fu  teil senken  Dr  c
24. sind  erl  schen ebenfalls s  mtliche Gew  hrleistungs  und Haftungsanspr  che bez  glich  des kompletten Antriebssystems  Dies gilt auch f  r den Fall des nicht ordnungsgem    en  Ein  und Ausbaus  des nicht bestimmungsgem    en Gebrauchs  der unsachgem    en  Behandlung und falschen Bedienung oder wenn Hettich Franke etwaige Sch  den aus  anderen Gr  nden nicht zu vertreten hat     4 3 Entsorgung       Beachten Sie bei der Entsorgung des nicht gebrauchsf  higen Antriebssystems die  geltenden Umweltschutzbestimmungen des jeweiligen Landes      Batterien sind gem     der AltBattVO zu entsorgen      Dieses Produkt unterliegt nicht der EU Richtlinie 2002 96 EG  WEEE  und deren  Erg  nzung EU Richtlinie 2003 108 EG    V ACHTUNG     gt  Batterie niemals wieder aufladen  Explosionsgefahr     gt  Batterie von Kindern fernhalten  nicht ins Feuer werfen  kurzschlie  en oder auseinander   nehmen   Batterie  und Ger  tekontakte vor dem Einlegen bei Bedarf reinigen   Ersch  pfte Batterien umgehend aus dem Ger  t entfernen  Erh  hte Auslaufgefahr    Batterie keinen extremen Bedingungen aussetzen  z  B  auf Heizk  rpern    direkte Sonnenstrahlung  Erh  hte Auslaufgefahr     gt  Kontakt mit Haut  Augen und Schleimh  uten vermeiden  Bei Kontakt mit Batteries  ure  die betroffenen Stellen sofort mit reichlich klarem Wasser sp  len und umgehend einen  Arzt aufsuchen    vv  D    v  D       5 Technische Daten                      Netzspannung  230 V AC  Leistungsaufnahmen   70 W  Motorspannung 
25. use  incorrect treatment and incorrect  operation  or if any other damages should exist for which Hettich Franke has no responsibility     Copyright 2013  Hettich Franke GmbH  amp  Co  KG  Balingen    12    2 Declaration of Incorporation    In accordance with Appendix Il  Part 1  Section B of Directive 2006 42 EC by the European  Parliament and the European Council from 17 05 2006 on machines and concerning the  revision of Directive 95 16 EC  revised version       on behalf of the company  Hettich Franke GmbH  amp  Co  KG    the signatory declares   The Mosys electromechanical drive unit for electrically adjustable slatted frames serves the  purpose of adjusting the head and or foot section     The type designation is  Mosys    Within the scope of the conformity assessment  the required specific technical documents   have been prepared and lodged  Upon reasonable request  the specific technical documents  can be provided to the national authorities in paper or electronic form  The specific technical   documents can be requested from     Richard Weinzierl  Hettich Franke GmbH  amp  Co  KG  72336 Balingen     name  address        The product also complies with the following European Directives     Machinery Directive 2006 42 EC  RoHs Directive 2011 65 EG   EMC Directive 2004 108 EC  R amp TTE Directive 1999 5 EC    The following harmonised standards were applied     EN 55014 1 2006 A1 2009 A2 2011   EN 55014 2 1997 A1 2001 A2 2008   EN 61000 3 2   EN 61000 3 3   EN 60335 1 201
    