Home

Betriebsanleitung Dubliergerät EDG 1

image

Contents

1. Observe the recognized regulations for work safety Usage only by qualified personnel Check the unit for technically immaculate condition 4 2 Initial operation and adjustment of the temperature unit Connect the unit to the enclosed power cord and to a protective grounded socket The main switch is located on the back of the unit next to the plug The pre setting for the units for the European Union is C and for the units for the USA F After turning the main switch m ef you have 4 seconds left to select a temperature unit For a display in degree Celsius press the button DOWN arrow down the letter C will be displayed For a display in degree Fahrenheit press the button UP arrow up the letter F will be displayed After 4 seconds you will hear a short signal and the unit is in standby mode After this you cannot change the temperature unit anymore The selected temperature unit will remain saved even after turning the unit off Note concerning the Fahrenheit display Internally the unit always calculates with degree C and then transforms the numbers using the following formula C x 1 8 32 The results are numbers with a dot which cannot be displayed and will be rounded up or down Example 50 C 2122 0 F Display 122 51 C 123 8 F Display 124 Therefore the value 123 will never be displayed 4 3 Filling the device Open the cover of the unit and skim condensation water
2. Abhilfe Ger t zum Service Der Fehler tritt auch auf wenn versucht wird das Ger t bei einer Raumtemperatur von weniger als 10 C zu betreiben Abhilfe Ger t bei h herer Temperatur betreiben Es kann etwas dauern bis das Ger t die h here Temperatur angenommen hat R hrwerk l uftnach dem Start nic ht sofort an Dies ist kein Fehler Das Ger t heizt erstmals solange auf bis der Bodenf hler eine Grundtemperatur meldet Erst dann wird das R hrwerk freigegeben Diese Funktion ist n tig um eventuell erstarrte Masse zu l sen Abhilfe Warten bis Grundtemperatur erstmals erreicht werden R hrwerk l uft kurz an und bleibt dann stehen Der berlastschutz f r das R hrwerk hat ausgel st Dies kommt vor wenn sich erstarrte Masse im Topf befindet und zerkleinert werden soll Abhilfe Keine n tig das R hrwerk startet nach einer Pause von 15 Sekunden erneut Dieser Vor gang kann sich mehrmals wiederholen Im Drehkreis befindet sich ein Fremdk rper der das R hrwerk blockiert Abhilfe Ger t Abschalten Netzstecker ziehen und Fremdk rper entfernen Bei Deformationen am R hrwerk Ger t zum Service R hrwerk l uft nicht wiederkehrender kurzer Signalton Deckel ist nicht geschlossen Auch wenn der Deckel offen ist l uft das Programm weiter Aus Si cherheitsgr nden muss das R hrwerk jedoch abgeschaltet werden Abhilfe Deckel schlie en Bleibt der Deckel Uber lange Zeit offen wird das Programm nicht ord nungs
3. 3 2 Leistungsmerkmale Schutzklasse 1 SchutzmaBnahme mit Schutzleiter Gewicht unbef llt F llmenge Leistung im Lastbetrieb Leistung im Standby Modus Leistung Heizungen 3 3 Merkmale EU Version Netzspannung Netzfrequenz Sicherung Anschluss 3 4 Merkmale US Version Netzspannung Netzfrequenz Sicherung Anschluss 3 5 Aufstellung Lagerbedingungen waagerecht aufstellen trockener Standort feste Unterlage Schutz vor S uren und Laugen trockene Lagerung bei Zimmertemperatur auf ausreichende Bel ftung achten kein Betrieb unter 10 C 61760V02 2010 07 ca 17 5 kg minimal 2 kg maximal 5 5 kg 1300 Watt 2 3 Watt 1000 Watt 230 V 10 50 Hz 6 3 A tr ge Netzkabel Schuko 115 V 10 60 Hz 12 5 A tr ge Netzkabel USA Seite Page 5 von of 28 egger 4 Bedienung 4 1 Vor Inbetriebnahme Das Ger t entspricht dem Stand der Technik und den anerkannten sicherheitstechnischen Regeln trotzdem k nnen Gefahren entstehen Ger t nur in einwandfreiem Zustand und unter Beachtung der Betriebsanleitung betreiben Anerkannte Regeln f r Arbeitssicherheit beachten Verwendung nur durch qualifiziertes Personall Ger t auf technisch einwandfreien Zustand berpr fen 4 2 Inbetriebnahme und Einstellung der Temperatureinheit Verbinden Sie das Ger t mit dem mitgelieferten Netzkabel und einer schutzgeerdeten Steckdose Der Hauptschalter befindet sich an der R ckseite des Ger
4. erreichte Anzahl der Aufschmelzungen angezeigt Dr cken Sie die Taste M Die Anzahl der bereits erfolgten Aufschmelzungen wird angezeigt Hinweis Der Z hler wird immer aktualisiert wenn in der Kurve der Punkt TI erreicht wurde Wenn Sie den Z hler l schen und auf Null setzen wollen weil Sie die Masse soeben gewechselt haben dr cken Sie einmal auf Taste T2 solange die Anzahl der Aufschmelzungen angezeigt wird Zum ndern des Vorgabewertes der Aufschmelzungen dr cken Sie das UHR Symbol Der gespei cherte Wert wird angezeigt und kann durch die AUF oder AB Taste ver ndert werden Werk seitige Voreinstellung 3 Verlassen Sie die Memory Funktion wieder durch erneuten Druck der Taste M Die Werte werden permanent gespeichert Taste UHR Uhrensymbol Die Einstellung kann nur im Standby Modus bis zum Start des Programmablaufs erfolgen Dr cken Sie die Taste UHR das Display zeigt blinkend die voreingestellte Stundenzahl an Der Wert kann nun mittels der Pfeiltasten verstellt 0 199 Stunden werden Durch erneutes Dr cken auf die Taste UHR verlassen Sie diesen Modus wieder Der Wert wird permanent gespeichert Taste UHR STARTEN Uhrensymbol mit Kurve Mit dieser Taste starten Sie die Uhrfunktion Diese Funktion kann nur aus dem Standby Modus und bei geschlossenem Deckel gestartet werden Das Display zeigt nun die Anzahl der verbleibenden Stunden bis zum Einschalten des Ger
5. F and 97 C 206 6 F O Then leave this function by pressing TI again A new value will be permanently adapted even after the power is turned off Unless the point T1 has not been exceeded in the display curve the new setting will immediately be adapted into the new program Factory pre setting 93 C 199 4 F Button T2 standby mode program run Pressing this button the pre set standby temperature is displayed If you want to change it change the value using the button UP or DOWN The range for adjusting is between 40 C 104 F and 50 C 122 F Then leave this function by pressing T2 again A new value will be permanently adapted even after the power is turned off A new setting will immediately be adapted into the new program and the temperature will be readjusted Factory pre setting 47 C 116 6 F Button M Memory The unit is equipped with a memory function This function counts the melting procedures that have already been done compares the number with a pre set value and reminds you of chang ing the duplicating material by flashing at the display Settings for the melting cycles can only be done in the standby mode in the program mode only the number of the melting procedures that have already been reached will be displayed Press the button M The number of the melting procedures that have already been done will be displayed Note The counter will always be updated when the point
6. if any at the cup seal If some conden sation water leaves the unit housing please remove it with a trap paper cloth The split between the cup and the housing is liquid proof Depending on the application there are different methods for filling the unit 1 Empty unit Handling the cover is very easy Pull the cover a little bit to the front using the handle until it disengages Then lift the cover slightly and turn it to the side Lifting the cover is very impor tant because otherwise you might strip off the seal Finally turn the cover back again until the angle press the cover a little bit down vertically using the handle and re engage it A well maintained and slightly greased seal facilitates the procedure Open the cover and fill the roughly crushed duplicating material into the unit The smaller the pieces are the more you can fill in Please do not fill through the agitator because otherwise the cover might be lifted and material could escape 61760V02 2010 07 Seite Page 20 von of 28 egger Later as long as the unit is in the heating up phase and the material is already melted you can re fill material But be careful do not throw material inside danger of splashing and fire When high quantities of duplicating material are required you can refill it until approx 1 5 cm be low the margin of the cup Information Material level until the upper blade of the agitator corre sponds to approx 4 5 kg until 1 5 cm be
7. Bereits gef lltes Ger t mit erstarrter Dubliermasse Achten Sie bitte darauf dass die Masse nicht h her als bis zur obersten Klinge des R hrwerks geht Das R hrwerk ist stark genug um die erstarrte Masse zu zerkleinern w rde aber bei einer berf llung den Deckel heben und Masse nach au en dr cken 4 4 Starten des Ger tes Programmablauf Wir gehen davon aus Sie haben bereits alle sp ter beschriebenen egger EDG 1 Programmierungen vorgenommen bzw Sie verwenden die von uns f r Sie bereits vorgegebenen Einstellungen Zum Starten muss der m Deckel geschlossen sein sonst ert nt ein Dauerton beim Startversuch Dr cken Sie die Taste Start TI Eine kurze Beschreibung des Programmablaufs AA 2 Das Ger t beginnt sofort aufzuheizen Auf der Frontplatte leuchtet die entsprechende Anzeige Das R hrwerk setzt nach dem Erreichen einer Grundtemperatur erst sp ter ein Wenn das R hrwerk l uft sollten Sie wenn n tig Masse nachlegen Beim ffnen des Deckels h lt das R hrwerk sofort an Ein wiederkehrendes Signal erinnert Sie daran den Deckel wieder zu verriegeln Wenn die maximale Temperatur TI erreicht ist wechselt die Anzeige auf TI Das Ger t h lt nun die Temperatur f r 3 Minuten um auch letzte St cke aufzuschmelzen Legen Sie in dieser Phase keine Masse nach Danach beginnt die Abk hlphase Die Anzeige wechselt der Ventilator springt an und das R hrwerk l uft Das Ger t k hlt die Masse nun ab bis 1 Gr
8. TI is reached If you want to erase and reset the counter because you have just changed the material press the button T2 as long as the number of melting procedures is displayed Press the CLOCK symbol to change the given value of the melting procedures The saved value will be displayed and can be changed using the button UP or DOWN Factory pre setting 3 Leave the memory function by pressing the button M again The values will be saved perma nenily 61760V02 2010 07 Seite Page 22 von of 28 egger Button CLOCK clock symbol The setting can only be done in the standby mode until the start of the program run Press the button CLOCK the pre set number of hours is Ti displayed flashing Now the value can be changed using the arrow pai buttons 0 199 hours Leave this mode pressing the button CLOCK The value will be permanently saved START o OONO egger EDG 1 Button STARTC LOC K clock symbol with curve Using this button you start the clock function This function can only be started out of the standby mode and if the cover is closed Now the number of the remaining hours until the start of the unit will be displayed This function can only be finished turning the power switch 5 Maintenance and servicing The unit must be unplugged and cooled down sufficiently for all maintenance procedures see Risks and Dangers Removing the agitator WARNING The agitator is sh
9. The display changes the ventilator starts and the agitator runs Now the unit cools the material down to 1 degree below the selected standby temperature T2 Now the display turns to T2 The unit regulates the given standby temperature with an accuracy of 1 C 33 8 F when the cup is almost empty the temperature can temporarily rise by 2 C 35 6 F Then the ventilator starts immediately The program run can only be stopped by turning off the main switch Summary turn the unit on fill the unit press TI the rest is done automatically Ending the program turn off the power switch at the back of the unit 61760V02 2010 07 Seite Page 21 von of 28 egger 4 5 Programming signification of the buttons For easy programming of the unit proceed according to the following principle Using the main switch at the back of the unit you can enter the standby i mode either C or F will be displayed m x To leave a function use the button which you used to enter the respective function In the majority of the cases the respective display will flash Button T1 Start Pressing this button in the standby mode will start the program run If egger EDG 1 you press this button again after starting the program the pre set melting temperature will be displayed If you want to change it ee change the value using the button UP or DOWN arrow buttons The range for adjusting is between 85 C 185
10. be used at a socket with protective grounding with the voltage indicated on the type plate All security rules for the handling of electric devices must be complied Only oper ate the unit at a dry location and do not dip it into liquids 2 Ensure that there is always sufficient ventilation The openings of the ventilation must be freely accessible minimum distance 15 cm The air stream of the ventilator must be able to escape freely Do not direct the air stream to persons The unit is not to be installed heat accumulation 3 Except the seals which are accessible from outside the unit has no parts that must be main tained or adjusted by the user The unit should only be opened by qualified persons Unplug the unit before you open it Only use originals parts approved by the manufacturer Interventions to the unit especially intentions to repair the unit lead to the expiry of the warranty and the liability 4 Unplug the unit before you clean and service it especially for work done in the area of the agi tator The agitator is ground and very powerful Disregarding this advice could cause serious inju ries 5 Replace the power cord completely if it is damaged Do not keep on working Do not unplug the unit by pulling the power cord 6 Do not use solvents for cleaning the unit 61760V02 2010 07 Seite Page 17 von of 28 egger 7 Ensure that unqualified persons especially children do not have access to the unit Only qual
11. llen des Ger tes gibt es je nach Anwendungsfall verschiedene Methoden 1 Leeres Ger t Die Bedienung des Deckels ist ganz einfach Ziehen Sie den Deckel am Griff etwas nach vorne bis er ausrastet Danach heben Sie den Deckel leicht an und schwenken ihn zur Seite Das Anheben ist ganz wichtig sonst kann die Dichtung abgezogen werden Zum Schlie en schwenken Sie den De ckel wieder zur ck bis zum Winkel dr cken den Deckel am Griff senkrecht etwas nach unten und rasten den Deckel wieder ein Eine gepflegte und leicht gefettete Dichtung erleichtert den Vor gang ffnen Sie den Deckel und f llen Sie grob zerkleinerte Dubliermasse in das Ger t Je kleiner die St cke sind um so mehr k nnen Sie einf llen Bitte nicht ber das R hrwerk f llen da sonst der Deckel angehoben werden kann und Masse austritt Sie k nnen sp ter solange sich das Ger t in der Aufheizphase befindet und die Masse bereits etwas zusammengeschmolzen ist noch Masse nachf llen Dabei vorsichtig sein Masse nicht hi neinwerfen Spritz und Verbrennungsgefahr Bei erh htem Bedarf an Dubliermasse k nnen Sie bis etwa 1 5 cm unter den Topfrand nachf llen Zur Information Massespiegel bis zur obersten Klinge des R hrwerks entspricht etwa 4 5 kg bis 1 5 cm unter den Topfrand entspricht etwa 5 5 kg F llen Sie das Ger t in jedem Fall also auch bei sehr kleinem Bedarf mindestens bis zur H lfte sonst kann es passieren dass die Fehlerschutzschaltung ausl st 2
12. tes neben dem Stecker Die Voreinstellung f r EU Ger te ist C f r US Ger te F Nach seiner Bet tigung haben Sie m Ce 4 Sekunden Zeit die Temperatureinheit zu w hlen z F r eine Anzeige in Grad Celsius bet tigen Sie die AB Pfeil nach unten Taste im Display sehen Sie den Buchstaben C F r eine Anzeige in Grad Fahrenheit dr cken Sie die AUF Pfeil nach oben Taste im Display se hen Sie den Buchstaben F Nach Ablauf dieser 4 Sekunden h ren Sie ein kurzes Signal und das Ger t befindet sich im Standby Modus Danach ist eine nderung der Einheit nicht mehr m glich Die gew hlte Einheit bleibt auch nach einem Abschalten des Ger tes gespeichert Hinweis zur Fahrenheitanzeige Das Ger t rechnet intern immer mit Grad C und rechnet nach der Formel Grad C x 1 8 32 Dadurch kommt es zu Kommazahlen die jedoch nicht angezeigt wer den k nnen und auf bzw abgerundet werden Ein Beispiel 50 Grad C 131 0 Grad F Anzeige 131 51 Grad C 132 8 Grad F Anzeige 133 Der Wert 132 wird also niemals angezeigt werden 61760V02 2010 07 Seite Page 6 von of 28 egger 4 3 Bef llen des Ger tes ffnen Sie den Deckel des Ger tes eventuell vorhandenes Kondenswasser streifen Sie an der Topf dichtung ab Sollte etwas Kondenswasser aus dem Ger tegeh use kommen bitte mit einem Lappen Papiertuch entfernen Der Spalt zwischen Topf und Geh use ist fl ssigkeitsdicht Zum Bef
13. tes an Eine Beendigung dieser Funktion ist nur durch die Be t tigung des Netzschalters m glich 5 Wartung und Pflege Bei allen Wartungsarbeiten muss der Netzstecker gezogen werden siehe Risiken und Gefahren und das Ger t ausreichend abgek hlt sein Abnehmen des R hrwerks WARNUNG Das R hrwerk ist scharf geschliffen bitte seien Sie vorsichtig es besteht Verletzungsge fahr L sen Sie die Inbus Schraube normales Rechtsgewinde mit dem beiliegenden Schl ssel zu sammen mit der darunter liegenden Beilagscheibe Heben Sie das R hrwerk aus dem Topf Der Zusammenbau erfolgt in umgekehrter Reihenfolge Achten Sie bitte auf den richtigen Sitz der Mit nehmerstifte und vergessen Sie unter keinen Umst nden die Beilagscheibe Mit dem Schl ssel die Schraube fest anziehen Ein nicht richtig montiertes R hrwerk kann gro en Schaden an ihrem Ger t verursachen 61760V02 2010 07 Seite Page von of 28 egger Wechseln der Dichtungen am Ablaufhahn Um einen Wechsel der Dichtungen durchf hren zu k nnen muss der Topf leer sein R hrwerk nach Anleitung entfernen Auslassknopf etwas zur ckziehen bis das Querloch sichtbar wird Stecken Sie nun einen Stift Nagel alten Bohrer o durch das Querloch und schrauben Sie den Kugelknopf ab Nun k nnen Sie den Kolben nach vorne Richtung Topf ausdr cken Die beiden O Ringe vor sichtig entfernen Kolben dabei nicht verletzen Neue O Ringe mit etwas Vaseline einfetten und montieren Ko
14. ad unter der eingestellten Bereit schaftstemperatur T2 61760V02 2010 07 Seite Page 7 von of 28 egger Die Anzeige wechselt nun auf T2 Das Ger t regelt die vorgegebene Bereitschaftstemperatur mit einer Genauigkeit von 1 Grad bei fast leerem Topf kann es kurzzeitig zu einem Anstieg von 2 Grad kommen Dann setzt sofort der Ventilator ein Der Programmablauf kann nur durch das Ausschalten des Hauptschalters auf der R ckseite des Ger tes beendet werden Zusammenfassung Ger t einschalten Ger t bef llen TI dr cken Rest l uft automatisch Programm beenden Netzschalter R ckseite des Ger tes ausschalten 4 5 Programmierung Bedeutung dereinzelnen Tasten gilt folgender Grundsatz Mit dem Hauptschalter an der R ckseite des Ger tes gelangt man in den Standby Modus im Display ist entweder C bzw F ersichtlich Mit der Taste mit der sie die entsprechende Funktion betreten haben ai verlassen Sie diese Funktion wieder In den meisten F llen blinkt oder 2 leuchtet die dazugeh rige Anzeige Taste TI Start Ein Druck auf diese Taste im Standby Modus startet den Programm egger EDG 1 ablauf Nach dem Start wird durch einen weiteren Druck auf diese n Taste die voreingestellte Schmelztemperatur angezeigt Wird eine EN nderung gew nscht verstellen Sie den Wert durch die Tasten AUF SD oder AB Pfeiltasten m Der Einstellbereich reicht von 85 C bis 97 C Verlassen Sie dana
15. arply ground please be careful because of danger of injury Loosen the hexagon socket head screw and the washer that is below the screw standard right hand thread using the enclosed key Remove the agitator from the cup The re assembly will be similar but vice versa Ensure that the driver pin fits well and do not forget the washer under any circum stances Tighten the screw using the key An agitator which is not properly fixed could damage your unit seriously Changing the seal of the drain cock To change the seals the cup must be empty Remove the agitator following the instructions Pull back the outlet button until you can see the transverse hole Now plug the pin nail old drill or simi lar through the transverse hole and unscrew the ball button Now you can push out the piston forwards direction of the cup Remove the two o rings carefully Do not damage the piston Grease the new o rings with a little bit of Vaseline and mount them Insert the piston and tighten the ball button Insert the agitator and tighten it using the key Only use original o rings They are made of a special heat resistant material Seals for installation purposes are not suitable and can cause the escape of hot duplicating material Changing the axial seals These seals should be replaced not later than after 1 1 5 years depending on the use The new seal will be delivered including installation constructions If the seal is changed too late a leakage
16. aterial After a long standby time or a low standby temperature some duplicating material might settle at the edge if the cup is full Do not detach these deposits because the outlet could be blocked Solution Heat up again If needed increase TI melting temperature or and T2 standby tem perature 61760V02 2010 07 Seite Page 26 von of 28 8 Service After sale service NOTE egger In case of improper handling of the egger EDG 1 all warranty and liability claims will become ex tinct Transport or dispatch of the unit Only use the original packaging and a forwarding agent for the dispatch Parcel services or the postal service are not suitable because due to the high weight the unit could be damaged Al ways remove the duplicating material from the unit Feel free to call us we are pleased to help you In the case of damages and interference do not hesitate to contact us Ayb hlweg 59 87439 Kempten Germany Phone 49 0 831 58113 60 Fax 49 0 831 58113 14 E mail sales egger labor de www egger labor com Please indicate the following Model Leeeeeeeseetm Device number eeseeemmA 61760 1 V02 2010 07 61760V02 2010 07 ce Seite Page 27 von of 28 egger Notes 61760V02 2010 07 Seite Page 28 von of 28
17. ch diese Funktion durch erneutes Bet tigen von T1 Ein neu eingestellter Wert wird nun permanent also auch nach einer Stromabschaltung Ubernommen Solange in der Anzeigekurve der Punkt TI nicht berschritten wurde wird eine neue Einstellung sofort im Programm bernommen Werkseitige Voreinstellung 93 C Um die Programmierung des Ger tes m glichst einfach zu gestalten Taste T2 Standby oder Programmablauf Ein Druck auf diese Taste zeigt die voreingestellte Bereitschaftstemperatur an Wird eine Anderung gew nscht verstellen Sie den Wert durch die Tasten AUF oder AB Der Einstellbereich reicht von 40 C bis 50 C Verlassen Sie danach diese Funktion durch erneutes Bet tigen von T2 Ein neu eingestellter Wert wird nun permanent also auch nach einer Stromabschaltung bernommen Eine neue Einstellung wird sofort im Programm bernommen und die Temperatur nachgeregelt Werkseitige Voreinstellung 47 C 61760V02 2010 07 Seite Page 8 von of 28 egger Taste M Memory Funktion Das Ger t ist mit einer Memory Funktion ausgestattet Diese Funktion z z f 3 egger EDG 1 z hlt die bereits erfolgten Aufschmelzvorg nge vergleicht die Anzahl x mit einem voreingestellten Wert und erinnert Sie durch Blinken der a Anzeige an einen Wechsel der Dubliermasse Einstellungen f r die Einschmelzzyklen k nnen nur im Standby Modus ET vorgenommen werden im Programm Modus wird nur die bereits m r2
18. chaltet zeigt keine Funktion Die Ger tesicherung ist unterbrochen M gliche Ursache berspannung aus dem Netz oder Fehler im Ger t Abhilfe Ger tesicherung an der R ckseite pr fen und wenn n tig erneuern Es darf nur eine Sicherung mit dem angegebenen Wert und dem angegebenen Ansprechverhalten verwen det werden sonst besteht Gefahr L st die Sicherung erneut aus oder immer noch keine Funktion Ger t zum Service Die inteme nichtreversible Temperatursic herung hat ausgel st Abhilfe Ger t zum Service Ger t l sst sich mit Taste T1 nic ht starten und gibt Signalton Der Deckel ist nicht geschlossen Abhilfe Deckel schlie en wenn Fehler weiterbesteht ist der De ckelschalter defekt und muss vom Service erneuert werden Ger t l sst sich mit Taste UHR STARTEN nic ht in Betrieb nehmen Der Deckel ist nicht geschlossen Abhilfe Deckel schlieBen wenn Fehler weiterbesteht ist der Deckelschalter defekt und muss vom Service erneuert werden 61760V02 2010 07 Seite Page 11 von of 28 egger Display zeigt E E bedeutet ein interner Fehler ist aufgetreten Eine M glichkeit ist der egger EDG 1 Ubertemperaturschutz hat ausgel st Dies kann passieren wenn Ti versucht wurde das Ger t ohne bzw mit zu geringer F llung zu ne betreiben Abhilfe Ger t ausschalten abk hlen lassen und ausreichend f llen a Eine weitere M glichkeit ist ein Defekt an einem der drei F hler m r2
19. could occur which might destroy the engine and the parts of the unit 61760V02 2010 07 Seite Page 23 von of 28 egger Maintaining the unit Remove condensation water which might escape at the cover with cloth The housing can be cleaned using a tiny moist cloth maybe with a little bit of washing up liquid no solvent The hous ing must be completely dry before the commissioning Maintaining the cover seal Keep the seal clean and grease it from time to time with Vaseline If this seal is defect please con tact our technical service Maintaining the cup Empty the cup completely To remove residuals incline the unit slightly forwards Allow the unit to cool down completely Remove the agitator and clean the inner side after removing solidified re siduals using a moist cloth if necessary use a little bit of washing up liquid Never fill the unit with water because this could cause calcifications at the axial seal danger of leakage 6 Wananty The manufacturer will grant a warranty for the device of 2 years from the purchase date Exempt from warranty coverage are damages caused by improper handling of the device modifications to the device and self repair attempts Seals are products subject to wear and tear and are not covered by this warranty Damages that are caused by a late or no exchange of the seals are not covered by this warranty 7 Troubleshooting This list should help you to analyze and eliminate problems tha
20. crushed Solution No solution is necessary The agitator will start again after 15 seconds This procedure might be repeated several times Inside the rotation circle a foreign body is blocking the agitator Solution Turn the unit off unplug the unit and remove the foreign body If the agitator is deformed send the unit to after sale service The agitator does not operate a short recurrent signal tone is heard The cover is not closed Even if the cover is open the program continues However for safety rea sons the agitator must be turned off Solution Close the cover If the cover remains open for a long time the program will not operate properly Duplicating material has escaped from the cover The unit was overfilled Esoecially when solidified material is to be conditioned it is possible that large lumps have lifted the cover and material has escaped Solution Use less material Clean and maintain the cover seal The standby temperature T2 is not maintained exactly The unit regulates the temperature with an accuracy of 1 C 33 8 F Due to the thermal inertia of the material and the filling quantity which is not known to the unit temporary deviations might occur These deviations will be re adjusted There are clots in the duplicating material the outlet is bloc ked Material has been refilled too late and could not be melted in time Do not try to mix material which has already been conditioned with unmelted m
21. egger Betriebsanlertung Dubliergerat EDG 1 REF 61760 230 V Bitte lesen Sie die Betriebsanleitung aufmerksam bevor Sie mit dem Ger t arbeiten Bewahren Sie die Betriebsanleitung zum sp teren Gebrauch an einem sicheren Ort auf Q Wichtige Information A Warnung Deutsche Anleitung Seite 1 14 English version Page 15 27 61760V02 2010 07 Seite Page 1 von of 28 egger 1 Allgemeines 3 2 Sicherheitshinweise 3 2 1 Bestimmungsgem e Verwendung 3 2 2 Risiken und Gefahren 3 3 Installation 5 3 1 Lieferumfang 5 3 2 Leistungsmerkmale 5 3 3 Merkmale EU Version 5 3 4 Merkmale US Version 5 3 5 Aufstellung Lagerbedingungen 5 4 Bedienung 6 4 1 Vor Inbetriebnahme 6 4 2 Inbetriebnahme und Einstellung der Temperatureinheit 6 4 3 Bef llen des Ger tes 7 4 4 Starten des Ger tes 7 4 5 Programmierung Bedeutung der Tasten 8 5 Wartung und Pflege 9 6 Garantie 11 7 Problembehandlung 11 8 Service Kundendienst 13 61760V02 2010 07 Seite Page 2 von of 28 egger 1 Allgemeines Das Dublierger t egger EDG 1 wurde zum Schmelzen und Bevorraten von Dubliermassen entwi ckelt Das egger EDG 1 ist ein leistungsf higes kompaktes Dublierger t mit einem starken R hrwerk au tomatischer Erfassung der Schmelzzyklen und m glicher Timerfunktion Die F llung des Ger tes kann beliebig zwischen 2 kg und 5 kg je nach Bedarf variiert werden Ein Mikrokontroller mit 3 Temperaturf hlern steuert a
22. fnen Netzstecker ziehen Es d rfen nur vom Hersteller zugelassene Originalteile verwendet werden Eingriffe in das Ger t insbesondere eigene Reparaturversuche f hren zu Garantieverlust und Haftungsausschluss 4 Bei Reinigung und Pflege am Ger t besonders bei Arbeiten im Bereich des R hrwerks muss das Netzkabel abgezogen werden Das R hrwerk ist geschliffen und sehr kr ftig Schwerwiegende Ver letzungen k nnen bei Missachtung dieses Hinweises die Folge sein 5 Ist das Netzkabel besch digt ist dieses komplett auszutauschen es darf nicht weiter gearbeitet werden Netzstecker nicht am Netzkabel aus der Steckdose ziehen 6 Zur Reinigung des Ger tes keine L sungsmittel verwenden 61760V02 2010 07 Seite Page 3 von of 28 egger 7 Es ist sicherzustellen dass sachunkundige Personen insbesondere Kinder mit dem Ger t nicht in Ber hrung kommen Zur Arbeit mit dem Ger t sind ausschlie lich Fachkr fte oder von Laborinhaber berechtigte und eingewiesene Personen befugt Vor der Inbetriebnahme muss der Benutzer die Betriebsanleitung lesen diese befolgen und bei eventuellen Unklarheiten beim Hersteller r ck fragen 8 Starten Sie das Ger t nur mit geschlossenem Deckel und geschlossenem Auslasshahn Eine Deckelsicherung sch tzt Sie vor Verletzungen durch das R hrwerk Sollte diese Sicherung versagen Deckel wird ge ffnet und R hrwerk bleibt nicht sofort stehen muss das Ger t unverz glich au er Betrieb gesetzt werden
23. gem arbeiten Am Deckel ist Dubliermasse ausgetreten Das Ger t wurde berf llt Gerade wenn erstarrte Masse konditioniert werden soll kann es pas sieren dass gro e Brocken den Deckel anheben und Masse austritt Abhilfe Weniger Masse verwenden Deckeldichtung reinigen und pflegen Bereitsc haftstemperatur T2 wird nicht exakt eingehalten Das Ger t regelt die Temperatur mit einer Genauigkeit von 1 C Aufgrund der thermischen Tragheit der Masse und der f r das Ger t unbekannten F llmenge kann es zu kurzzeitigen Ab weichungen kommen Diese Abweichungen werden aber nachgeregelt 61760V02 2010 07 Seite Page 12 von of 28 egger Klumpen in der Dubliermasse Auslass verstopft Es wurde zu sp t Masse nachgelegt diese konnte nicht mehr rechtzeitig geschmolzen werden Versuchen Sie nicht bereits konditionierte Masse mit ungeschmolzener Masse zu vermischen Nach langer Bereitstellungszeit und niedriger Bereitstellungstemperatur kann sich bei einem vollen Topf etwas Dubliermasse am Rand absetzen Diesen Rand nicht l sen der Auslass k nnte verstopfen Abhilfe Nochmals aufheizen Gegebenfalls TI Aufschmelztermperatur oder und T2 Bereitstel lungstemperatur erh hen 8 Service Kundendienst ACHTUNG Bei nicht bestimmungsgem er Verwendung des egger EDG 1 erl schen s mtliche Garantie und Haftungsanspr che Transport oder Versand des Ger tes Versenden Sie das Ger t nur in der Originalverpackung und per S
24. heck all parts of the delivery for completeness and transport damages Please report missing parts or transport damages immediately to the dealer manufacturer 1 Unit 1 Power cord Hexagon key for the agitator 1 Operating manual 3 2 Technical data Protection class 1 Protection measure with protective conductor Weight unfilled Filling quantity Power at load operation Power in standby mode Power of the heating 3 3 Features of EU version Supply voltage Supply frequency Fuse Connection 3 4 Features of US version Supply voltage Supply frequency Fuse Connection 3 5 Initial operation storage conditions install the device horizontally dry location firm surface protection against acids and bases dry storage at room temperature ensure sufficient ventilation no operation below 10 C 50 F 61760V02 2010 07 approx 17 5 kg minimum 2 kg maximum 5 5 kg 1300 Watt 2 3 Watt 1000 Watt 230 V 10 50 Hz 6 3 A slow blow Power cord for EURO moulded plug 115 V 10 60 Hz 12 5 A slow blow Power cord USA Seite Page 19 von of 28 egger 4 Operation 4 1 Before putting into operation The unit is produced according to the latest technologies and according to the recognized safety regulations However the possibility of dangerous situations cannot be excluded Only use the unit in immaculate condition and in accordance with the operating instructions
25. i fied persons or persons who have been authorized and instructed by laboratory owners are enti tled to work with the unit Before commissioning the unit the user must read the operating manual follow it and contact the manufacturer in the case of obscurities 8 Only start the unit if the cover and the drain cock are closed A cover protection provides pro tection from injuries caused by the agitator If the protection fails the agitator does not stop im mediately if the cover is open turn off the unit immediately and send it to the manufacturer for servicing 9 During the melting phase the unit and even the surface of the device s casing will heat up However as long as the cover is closed there is no danger of burning Nevertheless avoid any contact The duplicating material can reach a maximum temperature of 97 C 206 6 F which could cause scalds Therefore never open the drain cock at this temperature Do not throw clots of duplicating material into the hot material because hot splashes could cause injuries especially protect the eyes 10 The unit has three over temperature protections one of them operates independently of the microprocessor If this independent protection actuates the unit cannot be used anymore and must be send to the manufacturer Do not try to bridge this prevention system because at normal operation it should never actuate If it actuates there is a serious problem that must be eliminated Othe
26. lben einsetzen und Kugelknopf wieder festschrauben R hrwerk wieder einsetzen und mit Schl ssel festziehen Verwenden Sie unter allen Umst nden nur die originalen O Ringe sie be stehen aus einem speziellen w rmebest ndigen Material Dichtungen aus dem Installations bereich sind ungeeignet und k nnen zum Auslaufen von hei er Dubliermasse f hren Wechseln der Achsdic htung Diese Dichtung sollte nach sp testens 1 1 5 Jahren je nach Einsatzdauer gewechselt werden Eine Einbauanleitung liegt dem neuen Dichtungspaket bei Bei zu sp tem Wechsel kann es zu einer Leckage kommen die den Motor und Teile des Ger tes zerst ren kann Pflege des Ger tes Entfernen Sie am Deckel eventuell austretendes Kondenswasser mit einem Tuch Das Geh use k nnen Sie mit einem leicht feuchten Tuch eventuell etwas Sp lmittel kein L sungsmittel reini gen Vor der Inbetriebnahme muss das Geh use vollkommen trocken sein Pflege der Deckeldic htung Halten Sie diese sauber und fetten Sie diese fter mit wenig Vaseline ein Sollte diese Dichtung ein mal defekt sein so wenden Sie sich bitte an unsere technische Beratung Pflege des Topfes Entleeren Sie den Topf vollst ndig Restentleerung m glich durch leichtes Kippen des Ger tes nach vorne Ger t vollst ndig abk hlen lassen Entfernen Sie das R hrwerk und reinigen Sie die Innen seite nach dem Entfernen von ausgeh rteten Resten mit einem feuchten Tuch ggf mit etwas Sp lmittel F l
27. len Sie das Ger t in keinem Fall mit Wasser dies kann zu einer Kalkablagerung an der Achsdichtung f hren Leckagegefahr 61760V02 2010 07 Seite Page 10 von of 28 egger 6 Garantie Der Hersteller leistet eine Ger tegarantie von 2 Jahren ab Kaufdatum Von der Garantie aus geschlossen sind Sch den bedingt durch unsachgem e Verwendung des Ger tes nderungen am Ger t und Versuche von Selbstreparaturen Dichtungen sind Verschlei teile und fallen nicht unter diese Garantie Sch den die durch zu sp t oder nicht ausgewechselte Dichtungen hervor gerufen werden fallen nicht unter diese Garantie 7 Problembehandlung Diese Aufstellung soll Ihnen helfen eventuell auftretende Probleme zu analysieren und zu beseiti gen Wir gehen davon aus das Ger t ist an einer funktionsf higen Steckdose angeschlossen Bei unklaren Fehlern senden Sie das Ger t bitte in jedem Fall zum Service Der H Schutzsc halter Ihrer Sromverteilung l st aus In das Ger t ist Feuchtigkeit eingedrungen es kommt zu einem Fehlerstrom Abhilfe Ger t vom Service berpr fen lassen Ger t wurde irgendwann gestartet und auf dem Display erscheint egger EDG 1 C oder F Es ist ein Stromausfall aufgetreten das Gerdt hat sich aus Sicher EN heitsgr nden im den Standby Modus zur ckgesetzt Dies gilt auch e wenn die Schaltuhrfunktion gestartet wurde Abhilfe Ger t neu starten GO 2 durch dr cken der Taste T1 Ger t einges
28. lle Funktionen des Ger tes Schnelles schonendes Aufheizen rasches R ckk hlen und Konstanthalten der Dubliermasse Das Ger t ist einfach zu be dienen und wartungsfreundlich 2 Sicherheitshinweise 2 1 Besimmungsgem e Verwendung Das Dublierger t EDG1 dient zur Aufbereitung von Dubliermassen im otoplastischen Labor Es ist f r alle gelartigen Dubliermassen die aufgeschmolzen werden spezifiziert Die Aufschmelzphase das R ckk hlen und die konstante Arbeitstemperatur werden Uber einen Mikroprozessor gesteuert Bei nicht bestimmungsgem er Verwendung erl schen s mtliche Garantie und Haftungsanspr che 2 2 Risiken und Gefahren 1 Das Ger tdarf nur an einer schutzgeerdeten Steckdose mitderam Typenschild angegebenen Netzspannung betrieben werden Alle Sic herheitsregeln im Umgang mitelektrischen Ger ten sind einzuhalten Ger t nur an einem trockenen Arbeitsplatz betreiben und nic ht in H ssigkeiten tau chen 2 Das Ger t muss ausreichend bel ftet werden Die Ventilations ffnungen m ssen frei zug nglich sein Abstand mindestens 15 cm Der Luftstrom des L fters muss frei austreten k nnen Luftstrom nicht auf Personen richten Das Ger t darf nicht eingebaut werden W rmestau 3 Im Ger t sind au er den von au en zug nglichen Dichtungen keine Teile die vom Betreiber gewartet oder eingestellt werden m ssen Das ffnen des Ger tes darf ausschlie lich von fach kundigen Personen durchgef hrt werden Vor dem f
29. low the margin of the cup corresponds to approx 5 5 kg In any cose fill the unit even when very small quantities are required at least until the half be cause otherwise the error protection circuit might actuate 2 Unit already filled with solidified duplicating material Please ensure that the level of the material is not higher than to the upper blade of the agitator The agitator has enough power to crush the solidified material but would lift the cover and push out material if the cup was overfilled 4 4 Starting the device program run We presume that you have already done the programming described egger EDG 1 above or use the given settings To start the unit the cover must be closed because otherwise a EB permanent tone will appear in the case of an intention to start the unit Press the button Start T1 DA A short description of the program run The unit immediately starts heating up At the front plate the respective temperature is disolayed The agitator starts after reaching a standard temperature When the agitator runs you should refill material if necessary When you open the cover the agita tor stops immediately A recurrent signal reminds you of locking the cover again When the maximum temperature T1 is reached the display turns to T1 Now the unit maintains the temperature for 3 minutes to melt the last pieces as well Do not refill material in this phase Then the cooling down phase starts
30. pedition Paketdienst oder Post ist nicht geeignet da es durch das hohe Gewicht des Ger tes leicht zu Sch den kommen kann Ent fernen Sie in jedem Fall die Dubliermasse aus dem Ger t Rufen Sie uns an wir helfen Ihnen gerne weiter F r die Behebung von Schadensf llen und St rungen stehen wir Ihnen gerne zur Verf gung egger Otoplastik Labortechnik GmbH Ayb hlweg 59 87439 Kempten Germany Telefon 49 0 831 58113 20 Fax 49 0 831 58113 13 E Mail labortechnik egger labor de www egger labor com Geben Sie bitte folgende Daten an Ger tetyp 2osssssseseseee Ger te Nummer eeeeee C 61760V02 2010 07 Seite Page 13 von of 28 Notizen 61760V02 2010 07 egger Seite Page 14 von of 28 egger Operating manual Duplicating unit EDG 1 REF 61760 230 V REF 61761 115 V gt ego os i uD ae od ME Please read the operating manual carefully before working with the device Please keep the op erating manual at a safe place for later reference o Important Information Caution 61760V02 2010 07 Seite Page 15 von of 28 2 1 2 2 3 1 3 2 3 3 3 4 3 5 4 4 2 4 3 4 4 4 5 Index General infomation Safety regulations Field of application Risks and dangers Installation Scope of delivery Technical data Features EU version Features US version Initial operation storage conditions Operation Before p
31. rwise in the extreme case danger of fire exists 11 The unit is equipped with a time pre selection Electric heating devices as the EDG 1 should never be used unsupervised The unit has several safety circuits In any case you use the time pre selection at your own risk and without claim for liability against the manufacturer In the case of a power outage for safety reasons the time pre selection and the normal function of the unit are stopped When the power returns the unit will be in the stand by mode which means without fur ther function 12 The unit is equipped with a no load protection If a unit is started unintentionally without load or with insufficient load it will turn off and switch to the error mode E is displayed This problem can only be resolved by tuming off the unit and allowing it to cool down In the error mode all functions are blocked The unit has three temperature sensors for control independent of the over temperature protection If one of the sensors is defect the unit is also in the error mode but cannot be reset and re started The unit must be sent to the manufacturer 13 Transport the unit carefully and only when it is cooled down Avoid shocks and hits because due the high weight the cup could be deformed Please regard also the information about trans port and dispatch in section 7 of this manual 61760V02 2010 07 Seite Page 18 von of 28 3 Installation 3 1 Scope of supply egger C
32. t might occur We presume that the unit is connected to a functional socket In the case of unclear errors please send the unit to after sale service The protection switch A of your power distribution actuates Moisture entered the unit fault current occurs Solution Let the after sale service check the unit The unit was started anytime and C orF are displayed A power outage occurred and the unit returned for safety reasons to the standby mode This also applies when the clock timer function was started Solution Re start the unit by pressing button T1 61760V02 2010 07 Seite Page 24 von of 28 egger The unit is on no function The unit s fuse is interfered Possible reason Excess voltage from the power line or an error inside the unit Solution Check the unit s fuse at the back and replace it if necessary Only use a fuse with the stated value and the stated response properties because otherwise a dangerous situation might occur If the fuse activates again or if there is still no function please send the unit the after sale service The intemal ineversible over temperature protection has not actuated Solution Send the unit to after sale service The unit cannot be started with the button TL and is sending a signal tone The cover is not closed Solution Close the cover If the error does not disappear the cover switch is defect and must be replaced by after sale service The unitcannot be operated b
33. und zum Service an den Hersteller gesandt werden 9 Das Ger t erw rmt sich in der Aufschmelzphase auch an der Oberfl che des Geh uses Es be steht bei geschlossenem Deckel keine direkte Verbrennungsgefahr vermeiden Sie jedoch einen Kontakt Die Dubliermasse erreicht eine Temperatur von maximal 97 C die zu Verbr hungen f h ren kann ffnen Sie deshalb niemals den Auslasshahn bei dieser Temperatur Werfen Sie keine Dubliermasseklumpen in die hei e Masse hei e Spritzer k nnten Sie verletzen besonders Augen sch tzen 10 Das Ger t ist mit drei Temperatursicherungen von denen eine Sicherung unabh ngig vom Mik roprozessor arbeitet ausgestattet Sollte diese unabh ngige Sicherung ausl sen so ist eine weitere Verwendung des Ger tes nicht mehr m glich es muss zum Hersteller gesandt werden Versuchen Sie nicht dieses Sicherungssystem zu berbr cken es d rfte im normalen Betrieb niemals ausl sen L st es dennoch aus liegt ein schwerwiegender Fehler vor der behoben werden muss sonst be steht im Extremfall Brandgefahr 11 Das Ger t ist mit einer Zeitvorwahlschaltung ausger stet Grunds tzlich sollten elektrische Heiz ger te dazu z hlt auch das EDG 1 nicht unbeaufsichtigt betrieben werden Das Ger t ist mit di versen Sicherheitsschaltungen versehen Sie benutzen die Zeitvorwahl in jedem Fall auf eigenes Risiko ohne Haftungsanspruch an den Hersteller Bei einem Stromausfall wird aus Sicherheitsgr nden die Zeitvor
34. utting into operation Initial operation and adjustment of the temperature unit Filling the device Starting the device Programming meaning of the keys Maintenance and servicing Warranty Troubleshooting Service After sale service 61760V02 2010 07 egger Seite Page 16 von of 28 17 17 17 17 19 19 19 19 19 19 20 20 20 20 21 22 27 egger 1 General information The duplicating unit egger EDG 1 was designed for the melting and stocking of duplicating materi als The egger EDG 1 is an efficient compact duplicating unit with a powerful agitator automatic reg istration of the melting cycles and a possible timer function The filling of the unit can arbitrarily vary between 2 kg and 5 kg depending on the requirements A micro controller with 3 temperature sensors controls all functions of the unit Quick and gentle heat ing up quick cooling down and keeping constant the duplicating material Easy handling and maintenance 2 Safety regulations 2 1 Appropriate use The duplicating unit EDG1 serves for the preparation of duplicating materials in otoplastic laborato ries It is specified for all gelatinous duplicating materials that can be melted The melting phase the cooling down and the constant operating temperature are controlled through a micro proces sor If the unit is not used properly any warranty and liability claims become extinct 2 2 Risks and dangers L The unit shall only
35. wahl und die normale Funktion des Ger tes unterbrochen Wenn sich der Strom wieder einschaltet befindet sich das Ger t im Standby Modus also ohne weitere Funktion 12 Das Ger t ist mit einem Leerlaufschutz ausgestattet Sollte versehentlich ein unbef lltes oder ungen gend gef lltes Ger t gestartet werden schaltet es sich nach einiger Zeit ab und geht in den Fehlermodus Anzeige E auf dem Display Dieser Fehler kann nur durch ein Ausschalten und Abk hlen des Ger tes beendet werden Im Fehlermodus sind alle Funktionen gesperrt Zur Rege lung befinden sich im Ger t drei Temperaturf hler unabh ngig von der Temperatursicherung Sollte einer dieser F hler defekt sein geht das Ger t ebenfalls in den Fehlermodus kann jedoch nicht mehr zur ckgesetzt und gestartet werden Ger t muss an Hersteller gesendet werden 13 Transportieren Sie das Ger t vorsichtig und nur im abgek hlten Zustand Vermeiden Sie St e und Schl ge Durch das hohe Gewicht kann es sonst zu Deformationen am Topf kommen Beach ten Sie auch bitte unsere Hinweise zum Transport und Versand unter Punkt 7 dieser Anleitung 61760V02 2010 07 Seite Page 4 von of 28 3 Installation 3 1 Lieferumfang egger Pr fen Sie alle Teile der Lieferung auf Vollst ndigkeit und Transportsch den Fehlende Teile oder Transportsch den bitte sofort Ihrem H ndler Hersteller melden 1 Ger t Netzkabel 1 Inbusschl ssel f r das R hrwerk 1 Betriebsanleitung
36. y pressing the button SIARTCLOCK The cover is not closed Solution Close the cover If the error has not disappeared then the cover switch is defect and must be replaced by after sale service E is displayed If E is displayed an internal error has occurred The over temperature protection might have been actuated This can happen when the unit egger ALLE has been operated without any filling or with an insufficient filling EB KS Solution Turn the unit off allow it to cool down and fill it sufficiently Another possible reason could be a defect on one of the sensors IO 2 Solution Send the unit to after sale service The error also occurs when the unit is operated at a room temperatures below 10 C 50 F Solution Operate the unit at higher temperatures Some time might pass until the unit has adapted to the higher temperature The agitator does not start immediately after running the program This is not an error The unit first heats up until the ground sensor reports a standard temperature Only then is the agitator released This function is necessary to detach solidified material if any Solution Wait until a standard temperature is reached for the first time 61760V02 2010 07 Seite Page 25 von of 28 egger The agitator starts and then stops after a short time The overload protection for the agitator has actuated This happens when there is solidified mate rial inside the cup which must be