1. NV 74 HY imi Series Accessories Nivotemp NV 74 HY VS clogging indicator A Optionen a BFA filling adapter j SSR stilling tube with filling VA floatand immersion tube VA adapter Connector MT for Multiterminal M3 MTS for Multiterminal incl S stilling tube M12 FCT Fluidcontrolterminal 2M12 Temperatur Pt100 Temperature sensor RTD SE mm KT _ Temperature transmitter 370 TK Temperature contact 500 T50NO 50 C closer T60NO 60 C closer Quantity of level contacts T70NO 70 C closer 1 4 T80NO 80 C closer Level contact T50NC 50 C opener K opener closer T6ONC 60 C opener W change over T70NC 70 C opener L T80NC 80 Copener not available in combination with option FCT not available in combination with the option FCT MT and MTS 1 1 Functional Description 1 1 1 Level Control Using adjustable level contacts allows the application of standardised immersion tubes in oil tanks of different sizes and geometrical shapes The switching points are changeable to the requirement of the individual application at any time The level contacts are placed in closed housings They are positioned on a gold plated printed circuit board in defined positions on a 10 mm grid The minimum distance between two contacts is 40 mm The contacts are designed of closed and colour coded housings They are positioned on a printed circuit board wi
2. NO NC change cm scale on the rear side over wireless bistable level contacts From top to bottom green white function NO or NC yellow black red distance grid 10 mm blue Changing the colour order may result in malfunctions D r hangi f tact functi The level contacts are positioned as ordered but can be re adjusted NONG due to tuming the in steps of 10 mm if required 2 contacts at 180 The contact switching function NO or NC can be inverted as well by turning the contacts through 180 The housing is marked with two arrows The one pointing up when mounted indicates the current switching function AREAL The torque for the plastic screws must not exceed 5 cNm i i NC contact opens with rising level Closes with falling level thermal element TK PT KT FO00593x NO contact closed with rising level opens with falling level D H U U a ul H 1 af d af D d aji D WI af WI OI e bin Di a fh EE 4 a fu os gt at woo vie zb WI 1 KOSCH EN Oe 1 eli sos Eil a pim dx e d Ei me D zZ j Sw eel lt 52 juin afi Salen i wy 99 44 ua e Ui KEE el SOm gt a Cos 5 og i a yt a D SO ECO PIE A jun el E 33 a ORIGER v lui nne vluls ez lila ai SEA a lui 2 Wi m Sr Ab 1 Seoul t WE gt x DN HEN rEZ i efi EEN me D ija afi E Zen ely zee WH ey 0 NI NI D WM D WI a I
3. Technische Daten der Kontakte siehe 7 4 for technical data of contacts see chapter 7 4 BX100020 05 2014 Art Nr 9032037 25 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT64 Nivovent NV74 7 4 Technische Daten Kontakte 7 4 Technical Data of Contacts easyyust P ien Sg Niveaukontakt K Level contact Schaltfunktion NO NC switching function max Spannung 30 V max voltage max Schaltstrom 0 5A max switching current max Kontaktbelastung 10 VA max contact load min Kontaktabstand 40 mm 1 57 in min contact distance Niveaukontakt WwW Level contact Schaltfunktion Wechsler change over switching function max Spannung 30 V max voltage max Schaltstrom 0 5A max switching current max Kontaktbelastung 20 VA max contact load min Kontaktabstand 40 mm 1 57 in min contact distance Temperaturkontakt TK Temperature contact Schaltfunktion NO NC switching function max Spannung 30 V max voltage max Schaltstrom 2 5A max switching current max Kontaktbelastung 75 VA max contact load Schaltpunkt in C 50 60 70 80 switching point in C Schaltpunkt in F 122 140 158 176 switching point in F Schaltpunkttoleranz 3K switching tolerance max Hysterese 10K 3K max hysteresis Temperatursensor Pt100 Temperature sensor Klasse B DIN EN 60 751 class Toleranz 0 8K tolerance Temperaturtra
4. 4 1 1 Replacing the Filter Element To replace the filter element proceed as follows gt Unscrew the filter cover counter clockwise gt Remove the filter element and dispose it according the National rules and standards gt Insert the new filter element Make sure that the filter element has got the correct pore size gt Close the filter cover gt For filters with visual clogging indicator Reset the display to zero with the reset button 4 2 Refilling small Amounts of Oil With option BFA or SSR only gt Unscrew the filter cover counter clockwise gt Refill the oil slowly gt Insert the filter element and close the cover BX100020 05 2014 Art Nr 9032037 21 Bedienungs und Installationsanleitung Ww Installation and Operation Instruction E og e Nivotemp NT64 Nivovent NV74 easyyust EE 5 Service and Repair Risk due to defective device In case of failure switch off the device immediately and repair the fault The device should not be turned on again before elimination of the failure If the device shows irregularities please contact our service department call 49 0 2102 498955 or your local agent Please hold the data of the type plate ready If the device doesn t work correctly after elimination of failures and turning power on the device must be checked by the manufacturer Please ship the device with suitable packing to Buhler Technologies GmbH Service HarkortstraBe 29 40880 Ratingen
5. BX100020 05 2014 Art Nr 9032037 23 Bedienungs und Installationsanleitung Ww Installation and Operation Instruction E og e Nivotemp NT64 Nivovent NV74 easyyust EE 7 2 Standard Anschluss 7 2 Standard Pin Assignment belegung fur NT64 und NV74 for NT64 and NV74 Andere Belegung auf Anfrage other assignment on request Steckver M3 S6 C6 M12 2x M12 Connector binder Sockel base Sockel base 5 A S ER a Jl 4 20 o d o4 Nur Niveau 2 l 1 oi level contacts kontakt e ee 2 only TypK wg PE SE type K Nur Niveau 1 a nt 2 In 12 ae 4 level contacts kontakt e u s 2 only gt PE 4 em 3 S Typ W A type W 6 PE Niveau 2 h 5 aall TEP in level contacts kontakt e 3 a 2 A em 2 type K and Typ K und TKIKT un PE 4 TK KT 3 3 temperature Temperatur SEN 1 4 TK KT PT PE B 2 TK KT PT amp 3 Niveau 1 D e Ee level contacts a kontakt e i 3 type W and Typ W und 5 BE l temperature Temperatur TK KT PT pe 2 TK KT PT 3 24 BX100020 05 2014 Art Nr 9032037 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT64 Nivovent NV74 7 3 Technische Daten easyfust y een Ser 7 3 Technical Data NT64 NV74 Basiseinheit Basic unit max Betri
6. 0 0047 22 0 022 22 0 047 22 0 1 230 470 0 001 470 0 001 120 0 0047 120 0 022 120 0 022 Voltages and currents All B hler level contacts with reed switch can switch minimal Switching voltages of 10 uV and minimal switching currents of 1 pA The maximum values specified for the respective contact types apply Level contact with reed switches can therefore be used for SPS applications as well as for high loads within the maximum limits without hesitation Contact material All reed switches in Buhler level contacts use rhodium as the contact material for the actual contact areas Compared to gold rhodium is significantly more wear resistant to contact sparks and the contact blades are also less likely to burn and adhere Gold is only used as a support material for the ensuing rhodium layer The contact resistance of rhodium coated contact areas is no different than gold coated Based on the undeniable advantages of rhodium coating for contact areas reed switch manufacturers phased out gold plated contacts years ago 18 BX100020 05 2014 Art Nr 9032037 Bedienungs und Installationsanleitung v Installation and Operation Instruction D Ge e Nivotemp NT64 Nivovent NV74 easyfust Ee Gei US gt 3 1 Adjusting the Contacts The level contacts are mounted on a contact strip with cm scale inside the stem The contact housings are colour coded and must be installed according to the following order
7. Ausnahmef llen kann ber den Filter eine kleine Menge Ol nachgef llt werden 4 1 Filterelement wechseln Zum Wechsel des Filterelements gehen Sie folgenderma en vor ffnen Sie den Filterdeckel durch Drehen gegen den Uhrzeigersinn Entnehmen Sie das Filterelement und entsorgen Sie es gem den gesetzlichen Vorschriften Setzen Sie das neue Filterelement ein Achten Sie dabei unbedingt auf die richtige Filterfeinheit Schrauben Sie den Filterdeckel wieder auf Bei Filtern mit optischer Verschmutzungsanzeige Stellen Sie die Anzeige durch Dr cken der gelben Reset Taste auf Null WV WW WW 4 2 Nachfullen kleiner Olmengen Nur mit Option BFA oder SSR gt ffnen Sie den Filterdeckel durch Drehen gegen den Uhrzeigersinn gt F llen Sie ber die Nierenl cher langsam l nach gt Setzen Sie das Filterelement wieder ein und schlie en Sie den Deckel BX100020 05 2014 Art Nr 9032037 11 Bedienungs und Installationsanleitung Ww Installation and Operation Instruction E og e Nivotemp NT64 Nivovent NV74 easyyust Z 5 Service und Reparatur Risiko durch fehlerhaftes Gerat Schalten Sie das Ger t aus und trennen Sie es vom Netz Beheben Sie St rungen am Ger t umgehend Das Ger t darf bis zur Beseitigung der St rung nicht mehr in Betrieb genommen werden Sollte ein Fehler beim Betrieb auftreten wenden Sie sich bitte an unseren Service Tel 49 0 2102 498955 oder Ihre zust ndige Vertretung Halten Sie dazu bitte
8. Die farbliche Kenzeichnung der Kontakte stellt die bereinstimmung mit der Klemmenbelegung des Anschlusses sicher Die Schaltfunktion als fallend Offner NO oder als fallend Schlie er NC wird durch die Einbaulage der Kontakte bestimmt Zudem ist die Funktion als Wechsler verf gbar Die Signalisierung erfolgt nur elektronisch ber die Schaltausg nge 1 1 2 Temperatur berwachung Option Die Temperatur berwachung erfolgt ber ein Thermoelement das am Ende der Tr gerplatine aufgesteckt ist Hier stehen Temperaturkontakte mit fester Abstufung ein Pt 100 oder ein Temperaturtransmitter mit 4 20 mA Ausgangs zur Verf gung 1 2 Einsatzbereich Alle Ger tetypen sind ausschlie lich f r industrielle Anwendungen vorgesehen Es handelt sich nicht um Sicherheitsbauteile Die Ger te d rfen nicht eingesetzt werden wenn bei ihrem Ausfall oder bei Fehlfunktion die Sicherheit und Gesundheit von Personen beeintr chtigt wird Der Einsatz in explosionsgef hrdeten Bereichen ist nicht gestattet 4 BX100020 05 2014 Art Nr 9032037 Bedienungs und Installationsanleitung Ww Installation and Operation Instruction a og e Nivotemp NT64 Nivovent NV74 easyfust LEXUPAILLETRY 2 Wichtige Hinweise Bitte berpr fen Sie vor Einbau des Ger tes ob die genannten technischen Daten den Anwendungs parametern entsprechen berpr fen Sie ebenfalls ob alle zum Lieferumfang geh renden Teile vollst ndig vorhanden sind Der Einsatz der Ger
9. Germany In Addition attach the filled in and signed Declaration of Decontamination status to the packing Otherwise your repair order cannot be processed The form can be requested by e mail to service buehler technologies com 5 1 Disposal Regard the local regulations for disposal of electric and electronic equipment 6 Attached Documents Declaration of Conformity KX100020 Declaration of Contamination status 22 BX100020 05 2014 Art Nr 9032037 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT64 Nivovent NV74 easyfust 7 Anhang 7 1 Definitionen Die Kontaktlage ist wie folgt definiert i L2 j L3 L4 N K3 rot red eo K4 blau blue RR NO SchlieBer NC Offner TK Thermokontakt KT Temperaturtransmitter PT Temperatursensor Pt100 SSR Schwallschutzrohr Option Hinweis zum Analogausgang Temperatur Der Analogausgang kann mit maximal 30 V DC beaufschlagt werden 2 ien Sg 7 Appendix 7 1 Definitions The contact positions are defined as follows K1 gr n green W1 wei white K2 gelb yellow W2 schwarz black NO normally open NC normally closed TK Thermal contact KT Temperature transmitter PT Temperature sensor Pt100 SSR stilling tube option Note for analog output temperature The analog output is supplied with 30 V DC at maximum
10. Instruction ba Nivotemp NT64 Nivovent NV74 easyyust B HLER i NV 74 HY 0 Baureihe Zubeh r Nivotemp NV 74 HY VS Verschmutzungsanzeige V Optionen ol rung BFA Bef lladapter n SSR Schwallschutzrohr VA Schwimmer und Schaltrohr VA mit Bef lladapter Steckverbindung MT f r Multiterminal M3 MTS f r Multiterminal inkl S6 Schwallschutztrohr M12 FCT Fluidcontrolterminal 2M12 Temperatur 8 Pt100 Temperatursensor mm KT Temperaturtransmitter 370 TK Temperaturkontakt 500 T50NO 50 C Schlie er T60NO 60 C Schlie er Anzahl Niveaukontakte T70NO 70 C SchlieBer 1 4 T80NO 80 C Schlie er Niveaukontakt T50NC 50 C Offner K Offner SchlieBer T60NC 60 C Offner W gt Wechsler T70NC 70 C Offner T80NC 80 C Offner nicht in Verbindung mit Option FCT lieferbar nicht in Verbindung mit Option FCT MT und MTS lieferbar 1 1 Funktionsweise 1 1 1 F llstands berwachung Durch das easyjust System erm glicht der Nivotemp NT64 und Nivovent NV74 die Verwendung standardisierter Tauchrohrl ngen f r Olbeh lter unterschiedlicher Gr e und Form Die Schaltpunkte lassen sich jederzeit auf die Bed rfnisse der Anlage einstellen Die Niveaukontakte befinden sich geschlossenen Geh usen Sie werden einfach auf einer Kontaktleiste mit vergoldeten Kontakten im gew nschten Abstand positioniert Der Mindestabstand zwischen zwei Kontakten betr gt 40 mm das Raster 10 mm
11. Tauchrohr MS VA Bei der Baureihe Nivovent enth lt diese Option zus tzlichen einen Bef lladapter Option BFA Die Niveauschalter der Serie Nivovent sind zus tzlich mit einem Bel ftungsfilter ausgestattet F r diese Typen stehen die folgenden Optionen zur Verf gung e VS optische Verschmutzungsanzeige f r den Bel ftungsfilter Analoge Unterdruckanzeige Anzeigebereich 0 35 bar e BFA Bef lladapter inkl Rippenflansch mit Siebeinsatz Mittels dieser Option k nnen kleinere Mengen Ol ber das Bel ftungsfiltergeh use nachgef llt werden Hierzu wird in der gew hlten Variante das entsprechende Geh use eingebaut Welchen Typ Sie vor sich haben ersehen Sie aus dem Typenschild Die Typenschl ssel lauten folgenderma en NT 64 tinh Baureihe Nivotemp NT 64 Ausf hrung 8 Zubeh r MS Messing VA Schwimmer und Tauchrohr VA SSR _ Schwallschutzrohr Steckverbindung Temperatur M3 S6 Pt100 Temperatursensor M12 KT Temperaturtransmitter 2M12 M TK Temperaturkontakt L nge T50NO 50 CSchlieBer 230 T60NO 60 CSchlieBer SN T70NO 70 C Schlie er T80NO 80 C Schlie er Anzahl Niveaukontakte 1 4 T50NC 50 C ffner T60NC 60 C Offner Niveaukontakt T70NC 70 C Offner K ffner Schlie er T8ONC 80 C ffner WwW Wechsler BX100020 05 2014 Art Nr 9032037 3 Bedienungs und Installationsanleitung Installation and Operation
12. te ist nur zul ssig wenn das Produkt unter den in der Bedienungs und Installationsanleitung beschriebenen Bedingungen dem Einsatz gem Typenschild und f r Anwendungen f r die es vorgesehen ist verwendet wird Bei eigenm chtigen nderungen des Ger tes ist die Haftung durch die B hler Technologies GmbH ausgeschlossen die im Datenblatt und der Anleitung angegebenen Grenzwerte eingehalten werden berwachungsvorrichtungen Schutzvorrichtung korrekt angeschlossen sind die Service und Reparaturarbeiten die nicht in dieser Anleitung beschrieben sind von B hler Technologies GmbH durchgef hrt werden Originalersatzteile verwendet werden Diese Bedienungsanleitung ist Teil des Betriebsmittels Der Hersteller beh lt sich das Recht vor die Leistungs die Spezifikations oder die Auslegungsdaten ohne Vorank ndigung zu ndern Bewahren Sie die Anleitung f r den sp teren Gebrauch auf In dieser Anleitung werden folgende Warnzeichen und Signalw rter benutzt lt Warnung vor einer allgemeinen Gefahr E Z Netzstecker ziehen Warnung vor dem Einatmen giftiger Gase Atemschutz tragen Warnung vor tzenden Fl ssigkeiten Gesichtsschutz tragen oo Warnung vor explosionsgef hrdeten Bereichen Handschuhe tragen gt EE Signalw rter f r Warnhinweise Signalwort f r wichtige Information zum Produkt auf die im besonderen Ma e aufmerksam gemacht werden soll
13. Bedienungs und Installationsanleitung a Installation and Operation Instruction rer Nivotemp NT64 Nivovent NV74 easyzust TECHNOLOGIES Lesen Sie die Bedienungsanleitung vor dem Gebrauch des Ger tes gr ndlich durch Beachten Sie insbesondere die Hinweise unter Gliederungspunkt 2 Andernfalls k nnten Gesundheits oder Sachsch den auftreten Die B hler Technologies GmbH haftet nicht bei eigenm chtigen nderungen des Ger tes oder f r unsachgem en Gebrauch Read this instruction carefully prior to installation and or use Pay attention particularly to all advice and safety instructions to prevent injuries B hler Technologies GmbH can not be held responsible for misusing the product or unreliable function due to unauthorised modifications BX100020 05 2014 Art Nr 9032037 B hler Technologies GmbH Harkortstr 29 D 40880 Ratingen Tel 49 0 21 02 49 89 0 Fax 49 0 21 02 49 89 20 Internet www buehler technologies com Email fluidcontrol buehler technologies com Bedienungs und Installationsanleitung Ww Installation and Operation Instruction E og e Nivotemp NT64 Nivovent NV74 easyyust EE Inhaltsverzeichnis Seite a ee 1 131 lt BEE 3 1 1 Si gle NEE 4 1 1 1 F llstands berwach g errssesiieurnuiiinenniennnena inerant aaea aeea ASE aAA E A 4 1 1 2 Temperatur berwachung Option 4 1 2 Epeatzbereclt 2 siissatecdasneuceexeetuenentaceceeevehucuansidecuenvecunauseadaccenpassansieadecuesPueiagsabas
14. Signalwort zur Kennzeichnung einer Gef hrdung mit geringem Risiko die zu einem Sach schaden oder leichten bis mittelschweren K rperverletzungen f hren kann wenn sie nicht vermieden wird Signalwort zur Kennzeichnung einer Gef hrdung mit mittlerem Risiko die m glicherweise Tod oder schwere K rperverletzungen zur Folge hat wenn sie nicht vermieden wird GEFAHR Signalwort zur Kennzeichnung einer Gefahrdung mit hohem Risiko die unmittelbar Tod oder schwere K rperverletzung zur Folge hat wenn sie nicht vermieden wird BX100020 05 2014 Art Nr 9032037 5 Bedienungs und Installationsanleitung WW Installation and Operation Instruction E og e Nivotemp NT64 Nivovent NV74 easyyust EE H DE Das Ger t darf nur von Fachpersonal installiert werden das mit den Sicherheitsanforderungen und den Risiken vertraut ist Beachten Sie unbedingt die f r den Einbauort relevanten Sicherheitsvorschriften und allgemein g ltigen Regeln der Technik Beugen Sie St rungen vor und vermeiden Sie dadurch Personen und Sachsch den Der f r die Anlage Verantwortliche muss sicherstellen dass Sicherheitshinweise und Betriebsanleitungen verf gbar sind und eingehalten werden Unfallverhttungsvorschriften der Berufsgenossenschaften beachtet werden in Deutschland BGV A1 Grunds tze der Pr vention und BGV A3 Elektrische Anlagen und Betriebsmittel die zul ssigen Daten und Einsatzbedingungen eingehalten werden Schut
15. Up to three switching outputs plus Pt100 RTD or e Up to three switching outputs for level control plus one analogue output for temperature control The following options are available e SSR stilling tube with support ring The stilling tube is made of the same material as the immersion tube MS VA With series Nivovent this option includes an additional filling adapter option BFA The Nivovent series is equipped with an air breather filter with the following options e VS visual clogging indicator for the air breather filter analogue underpressure indicator display range 0 35 bar e BFA filling adapter incl ribbed flange with sieve insert this option allows that small oil quantities can be filled via the breather housing Therefore the corresponding housing is equipped in that version NT 64 Series Nivotemp NT 64 Design MS brass Accessories VA float and immersion tube stainless steel SSR stilling tube Connector Temperature Pt100 Temperature sensor RTD KT Temperature transmitter TK Temperature contact T50NO 50 CNO T60NO 60 C NO T70NO 70 C NO T80NO 80 C NO No of level contacts 1 4 T50NC 50 C NO T60NC 60 C NO Level contact T70NC 70 C NO K NO NC T80NC 80 C NO Ww change over BX100020 05 2014 Art Nr 9032037 13 Bedienungs und Installationsanleitung Ww Installation and Operation Instruction og e Nivotemp NT64 Nivovent NV74 easyjust LETTER
16. ch die Anwendung von Pr flampen bei der Installation der Ger te ist nicht zul ssig da durch diese kurzfristig ein zu hoher Strom flie en kann welcher die Reedkontakte besch digen kann Hier sollte man auf jeden Fall leistungslose Pr fmittel verwenden BX100020 05 2014 Art Nr 9032037 7 Bedienungs und Installationsanleitung Ww Installation and Operation Instruction E E e Nivotemp NT64 Nivovent NV74 easyyust EEN TECHNOLOGIES H A Kontaktschutzbeschaltungen fiir Reedschalter Bei Gleichspannung sollte eine Freilaufdiode nach Bild A parallel zum Kontakt angeschlossen werden Bei Wechselspannung sollte ein RC Glied nach Bild B und Tabelle 1 parallel zum Kontakt angeschlossen werden A B Kontakt Kontakt Go Last Last _o SCH Schutzdiode RC Glied VA 10 25 50 75 100 Spannung am Kontakt V R Ohm C uF R Ohm C uF R Ohm C uF R Ohm C uF R Ohm C uF 24 22 0 022 1 0 1 1 0 47 1 1 0 1 1 0 48 120 0 0047 22 0 022 1 0 1 1 0 47 1 0 47 110 470 0 001 120 0 0047 22 0 022 22 0 047 22 0 1 230 470 0 001 470 0 001 120 0 0047 120 0 022 120 0 022 Spannungen und Str me Alle B hler Niveaukontakte mit Reedschaltern k nnen minimale Schaltspannungen von 10 uV und minimale Schaltstr me von 1 uA schalten Es gelten die bei den jeweiligen Kontakttypen angegebenen Maximalwerte Darum k nnen Niveaukontakte mit Reedschaltern bedenkenlos sowohl f r SPS Anwendungen als au
17. ch f r hohe Belastungen im Rahmen der Maximalgrenzwerte eingesetzt werden Kontaktmaterial Bei allen Reedschaltern in B hler Niveaukontakten wird Rhodium als Kontaktmaterial im Bereich der eigentlichen Kontaktfl chen verwendet Rhodium hat im Vergleich zu Gold eine erheblich h here Verschlei festigkeit gegen ber Kontaktfunken und neigt auch weniger zum Verbrennen und Kleben der Kontaktzungen Gold wird ausschlie lich als Tr germaterial f r die nachfolgende Rhodiumschicht benutzt Der Ubergangswiderstand der Kontaktfl chen mit Rhodiumbeschichtung im Vergleich zu Goldbeschichtung ndert sich nicht Wegen der unbestreitbaren Vorteile der Rhodiumbeschichtung im Bereich der Kontaktflachen gibt es bereits seit Jahren bei keinem Reedschalterherstellee mehr Kontakte mit Goldbeschichtung 8 BX100020 05 2014 Art Nr 9032037 Bedienungs und Installationsanleitung Ww Installation and Operation Instruction a ay e Nivotemp NT64 Nivovent NV74 easyfust Ee Ge US gt 3 1 Verstellen der Niveaukontakte Die vom Schwimmer bet tigten Kontakte sind auf einer galvanisch vergoldeten Kontaktleiste mit cm Skala mit Kunststoffschrauben Kontaktleiste angebracht Die Kontaktgeh use sind verschiedenfarbig ausgef hrt und d rfen nur in folgender Reihenfolge auf die Kontaktleiste montiert werden cm Skala auf der R ckseite 8 i Kabellose bistabile Niveaukontakte ee meer Funktion fallend Schlie er NC a oder fallend Of
18. d anderen Einbauten einhalten Nach einer Demontage des Schwimmers muss der Magnet im Schwimmer beim erneuten Einbau oberhalb des Fl ssigkeitsspiegels liegen Kontrollieren Sie die Lage des Magneten mit einem Eisenst ck Die Nennspannung betr gt 24 V DC Der Anschluss erfolgt ber einen Steckverbinder Die Anschluss belegung finden Sie im Anhang Die Niveaukontakte sind gem Bestellung als Schlie er ffner oder Wechsler ausgef hrt und in der angegebenen Lage montiert Sowohl die Lage als auch die Schaltfunktion k nnen ge ndert werden Gehen Sie dazu wie in 3 1 beschrieben vor Die Kontaktlogik geht davon aus dass der Niveauschalter bei leerem Tank installiert wird d h er ist erst nach dem Bef llen in der Betriebsposition Hinweise zum korrekten Betrieb von Reedkontakten in B hler Niveauschaltern Reedkontakte sind konstruktionsbedingt sehr langlebige und zuverl ssige Bauteile Trotzdem sollte beim Einsatz folgendes beachtet werden Lebensdauer von Reedschaltern Die Lebensdauer von Reedschaltern kann bis zu 10 Schaltspiele betragen Sie wird vermindert durch hohe Belastung und oder falsche oder nicht vorhandene Schutzbeschaltung beim Schalten von induktiven kapazitiven oder Lampenlasten Deswegen ist sicherzustellen dass NIEMALS auch nicht kurzzeitig einer oder mehrere der maximal zul ssigen Grenzwerte berschritten werden und dass bei nicht rein ohmschen Lasten eine Kontaktschutzbeschaltung angebracht wird Au
19. die Daten des Typenschildes bereit Ist nach Beseitigung eventueller St rungen und nach Einschalten der Netzspannung die korrekte Funktion nicht gegeben muss das Ger t durch den Hersteller berpr ft werden Bitte senden Sie das Ger t zu diesem Zweck in geeigneter Verpackung an B hler Technologies GmbH Reparatur Service Harkortstra e 29 40880 Ratingen Deutschland Bringen Sie zus tzlich die Dekontaminierungserkl rung ausgef llt und unterschrieben an der Verpackung an Ansonsten ist eine Bearbeitung Ihres Reparaturauftrages nicht m glich Das Formular kann per E Mail angefordert werden service buehler technologies com 5 1 Entsorgung Bei der Entsorgung sind die gesetzlichen Vorschriften des Anwenderlandes zu beachten insbesondere die Vorschriften f r die Entsorgung von elektronischen Bauteilen 6 Beigef gte Dokumente Konformit tserkl rung KX100020 Dekontaminierungserklarung 12 BX100020 05 2014 Art Nr 9032037 Bedienungs und Installationsanleitung Installation and Operation Instruction vy Nivotemp NT64 Nivovent NV74 easyfust BWER H 1 Introduction The level switches Nivotemp NT64 and Nivovent NV74 are designed for level and temperature control in fluid systems Depending on the model the following configurations are available e Up to four switching outputs for level control or e Up to three switching outputs for level control plus one switching output for temperature control or e
20. e kein 21 4 1 1 Replacing the Filter Element une 21 4 2 Refilling small Amounts of Ol mean een 21 5 Service and Repair nassen 22 5 1 Nee E 22 6 Attached Documenis wriiscsscissccsccsscsisscsaccsaccis cecnessecncanccsieencdenseeacaeaactecccuceraeacacnsansieceensaseeceaes 22 7 AppendiX nee 23 7 1 M e 23 7 2 Standard Pin Assignment for NT64 and NVA4 nn 24 7 3 Reine EE EE 25 7 4 Technical Data of Contacts 0 0 ccceeeececeeeeeeeeeeeeeaeeeeeeeceaeeeceaeeeeaaeseeeeseaeeeseaeseeaeeseeeeeseaeeesaeeseaeeesaes 26 7 5 ME EE 27 2 BX100020 05 2014 Art Nr 9032037 Bedienungs und Installationsanleitung Ww Installation and Operation Instruction a og e Nivotemp NT64 Nivovent NV74 easyfust EE 1 Einleitung Der Nivotemp NT64 und Nivovent NV74 dienen zur berwachung des F llstandes und der Temperatur in Fluidsystemen Je nach Ausstattung stehen folgende Konfigurationen zur Verf gung e bis zu vier Schaltausg nge f r die F llstands berwachung oder e bis zu drei Schaltausg nge f r die F llstands berwachung plus ein Schaltausgang f r die Temperatur berwachung oder e bis zu drei Schaltausg nge f r die F llstands berwachung plus ein Ausgang Pt100 e bis zu drei Schaltausg nge f r die F llstands berwachung plus ein Analogausgang f r die Temperatur berwachung Folgende Optionen stehen zur Verf gung e SSR Schwallschutzrohr mit Zentrierscheibe Das Schwallschutzrohr ist in dem gleichen Material ausgef hrt wie das
21. ebsdruck 1 bar 14 5 psi 1 bar 14 5 psi max operating press Betriebstemperatur 20 CT 80 C AE 176 F 20 C 80 C 4 F 176 F operating temperature mit Kontakt K1OHT with contact HT Dichte Fluid Density fluid Schwimmer SK 601 0 80 kg dm 0 029 Ib in 0 80 kg dm 0 029 Ib in float SK 601 Schwimmer SK 221 0 85 kg dm 0 031 Ib in 0 85 kg dm 0 031 Ib in float SK221 Beliftungsfilter HY Hydac BF7 Air breather filter Filterfeinheit 3 um pore size Ausf hrung MS Type MS Schwimmer SK 601 PU PU float SK 601 Tauchrohr Messing brass Messing brass immersion tube Flansch PA PA flange Filtergeh use PA filter housing SSR Option Messing brass Messing brass SSR Option Ausf hrung VA Type VA Schwimmer SK 221 1 4571 1 4571 float SK 221 Tauchrohr 1 4571 1 4571 immersion tube Flansch PA PA flange Filtergeh use Zu PA filter housing SSR Option 1 4571 1 4571 SSR Option Niveaumessung level measurement Kontakt Typ max Anzahl K NO NC 4 K NO NC 4 type of contact max no Wechsler max Anzahl W 2 W 2 change over contact max no Temperaturmessung Temperature measurement max Anzahl Kontakte 1 1 max number of contacts Temp Kontakt TK TK temperature contact Temp Transmitter KT KT temp transmitter Temp Sensor Pt100 Pt100 temperature sensor
22. ecaveysausnunsadecererveusaanners 4 2 Wichtige Eelere EE 5 3 Aufbauen und Anschlie en E 7 3 1 Verstellen der Niveaukontakte AA 9 3 2 Nachtr gliche Montage eines Temperaturf hlers AAA 11 4 Meester eee eee 11 4 1 Filterelement wechseln uusssssensesnnnsnssananunununnanunnsnsunnnunnnnannnnnnnunnnnnnnnnsnnnnnnnnnannnannnnnnnnnnnnnsnnnnen 11 4 2 Nachf llen kleiner Olmengen AA 11 5 Semwleeund Reparatur a a en 12 5 1 EEO UN TEE 12 6 Beigef gte Dokumente uuunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnnneennnnnnnnn 12 7 Anhang as ee 23 7 1 Definitionen essen ee er een a aaa a aaa a aa aT A RAE aa 23 7 2 Standard Anschlussbelegung f r NT64 und NV74 useensnsenssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nn 24 7 3 Technische Daten eege gege E Eege bates setae 25 7 4 Technische Daten Kontakte ccccceeseececeeeeeceeeeeeeeeeesaeeeeeesaeseeeesaaceseeseaseseeseeseseeseeseeeeseneeeeenenaes 26 7 5 ABMESSUNGEN Mn ea ee ee ee ee erden 27 Contents Page RT ET E 13 1 1 Functional Description 14 1 1 1 Level COMIN sc csieciicahiadeccsncnetectdvaadacsustadudasieadeceussaaucasteadacsusteanehsieededsitaatdassnadedsvivasudassadecsutaavetaat 14 1 2 Temperature Control Option 14 1 3 dee AE 14 2 JOEREN 15 3 Anstallallon and Gonneetlon ee 17 3 1 Adjusting the eene 19 3 2 Retrofit of a Temperature Gensor naar 20 d Malnt nanG iiss teeter eee ee ee a an Sana Eee nen 21 4 1 Inspection We ET e
23. fner NO Von oben nach unten gr n wei gelb schwarz rot Abstandsraster 10 mm blau Bei einer anderen Zuordnung k nnen Fehlfunktionen auftreten Die Niveaukontakte sind ab Werk nach den Bestelldaten A De i wa i ndern der Kontaktfunktion positioniert k nnen aber nachtr glich in einem Raster von 10 mm MONG durch Drehen der verstellt werden Auch die Kontaktfunktion fallend Offner NO oder ki Kontakte um 180 fallend SchlieBer NC kann durch drehen der Kontaktgeh use um Ce 180 ge ndert werden Auf dem Geh use sind zwei Pfeile dargestellt Der Pfeil der nach oben zeigt weist auf die g ltige Kontaktfunktion hin AR HINWEIS Thermoelement TK PT KT F000593x Die Kunststoffschrauben nur mit maximal 5 cNm festziehen SITT dk Funktion NC Offner bei steigendem Niveau Schlie er bei fallendem Niveau Funktion NO i Schlie Ber bei steigendem Niveau Offner bei fallendem Niveau KONTAKT K10x qe OFFNER NC SCHLIESSER NO gt N3DNILVH HEWS 3109 VAOL WS 0 OW OG Are XVN eq ON HASSAINHOS NEN gt XOLA LYVLNOM MAX 24V DC AC 0 5A 10VA B HLER GMBH RATINGEN Po E Aurnnnsnenxsnenns A 000275X AenrnenesssEsnnend Die Kontaktlogik geht davon aus dass der Niveauschalter in einen leeren Tank installiert wird d h er ist erst nach dem Befiullen in der Betriebsposition Der Referenzpunkt f r den Nivea
24. gen KX 10 0020 Tel 49 0 21 02 49 89 0 Fax 49 0 21 02 49 89 20 Internet www buehler technologies com Dekontaminierungserklarung Ka Declaration of Contamination status As OIL TECHNOLOGIES Giltig ab valid since 2011 05 01 Revision 0 ersetzt Rev replaces Rev Die gesetzlichen Vorschriften schreiben vor dass Sie uns die Dekontaminierungserklarung ausgef llt und unterschrieben zur ck zu senden haben Die Angaben denen zum Schutz unserer Mitarbeiter Bringen Sie die Bescheinigung an der Verpackung an Ansonsten ist eine Bearbeitung Ihres Reparaturauftrages nicht m glich Legal regulations prescribe that you have to fill in and sign the Declaration of Contamination status and send it back This information is used to protect our employees Please attach the declaration to the packing Otherwise your repair order cannot be processed Ger t Serien Nr Device Serial no R cksendegrund Reason for return Ich best tige hiermit dass das oben spezifizierte Ger t ordnungsgem gereinigt und dekontaminiert wurde und keinerlei Gefahren im Umgang mit dem Produkt bestehen herewith declare that the device as specified above has been properly cleaned and decontaminated and that there are no risks present when dealing with the device Ansonsten ist die m gliche Gef hrdung genauer zu beschreiben In other cases please describe the hazards in detail Aggregatzustand bitte ank
25. ice shall be performed by trained staff only familiar with the safety requirements and risks Adhere to all relevant safety regulations and technical indications for the specific installation place DANGER Toxic and corrosive gases Protect yourself during maintenance against toxic corrosive gases Use gloves respirator and face protector under certain circumstances For direct tank top installation insert gasket and immersion tube into the flange dimensioned according to DIN 24557 Part 2 Fix the device with the screws included in delivery The float must move freely and must keep enough distance to the walls and to other equipment installed If the float had been demounted make sure that the magnet inside the float is placed above the surface Check its position using a piece of iron The nominal supply voltage is 24 V DC The device is connected via a connector on top Please find the pin assignment in the appendix The level contacts are designed as NO NC or change over contacts and are mounted in customized positions The position as well as the contact function can be changed as described in chapter 3 1 The switching logic assumes that the level switch is installed in an empty vessel implicating that the operating position is reached after filling the vessel Information on the correct operation of reed contacts in Buhler level switches Based on their construction reed contacts are very long lasting and reliable compo
26. nector off and carefully pull out the punched strip gt Remove the plastic screws from the contact housing and reposition the housing Use the cm scale on the back of the strip Regard the minimum distance 40 mm gt If necessary change the contact function gt Tighten the plastic screws hand tight gt Insert the contact strip into the tube gt Remount the adapter connector The markings on the adapter and on the contact strip must fit gt Remount the flange cover and gasket gt Remount the filter housing insert the filter element and tighten the filter cover example filter cover with housing and l example gasket flange cover optional temperature connector M3 with and gasket cont level contacts ct TK or Pt100 d connector socket plastic screws contact board filter element 3 2 Retrofit of a Temperature Sensor If required it is possible to retrofit a temperature sensor Please contact our service department or you local agent Please hold the data of the type plate ready 20 BX100020 05 2014 Art Nr 9032037 Bedienungs und Installationsanleitung Ww Installation and Operation Instruction a og e Nivotemp NT64 Nivovent NV74 easyfust EE ES W 4 Maintenance 4 1 Inspection and Service The device works maintenance free NV74 only Replace the filter element when clogged at least once a year In special cases a small amount of oil may be refilled via the Nivovent filter
27. nents Yet the following should be considered when using them Life of reed switches The life of reed switches reed switches can be up to 10 cycles This is reduces by high stress and or incorrect or the absence of protective circuits when switching inductive capacitive or lamp loads It s therefore important to ensure NEVER to exceed one or several of the maximum approved limits even temporarily and to install a contact protective circuit for loads which are not purely ohmic Using test lamps when installing the devices is also prohibited as these can temporarily allow too much current to flow which can damage the reed contacts In this case non volatile testing equipment should always be used BX100020 05 2014 Art Nr 9032037 17 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT64 Nivovent NV74 easyyust Asmar TECHNOLOG Contact protective circuits for reed switches Under direct current voltage a recovery diode per figure A should be connected parallel to the contact Under alternating current voltage an RC circuit per Figure B and Table 1 should be connected parallel to the contact A B contact contact o o 0 o R load C load oOo O Diode RC network VA 10 25 50 75 100 Voltage at contact V R Ohm C uF R Ohm C uF R Ohm C F R Ohm C uF R Ohm C uF 24 22 0 022 1 0 1 1 0 47 1 1 0 1 1 0 48 120 0 0047 22 0 022 1 0 1 1 0 47 1 0 47 110 470 0 001 120
28. not avoided z O m BX100020 05 2014 Art Nr 9032037 15 Bedienungs und Installationsanleitung Installation and Operation Instruction _ Nivotemp NT64 Nivovent NV74 easyyust YSU TER i Installation of the device shall be performed by trained staff only familiar with the safety requirements and risks Adhere to all relevant safety regulations and technical indications for the specific installation place Prevent failures and protect persons against injuries and the device against damage The person responsible for the system must secure that safety and operation instructions are accessible and followed local accident prevention regulations and standards are obeyed performance data and installation specifications are regarded safety devices are installed and recommended maintenance is performed national regulations for disposal of electrical equipment are obeyed Maintenance and repair Repairs on the device must be carried out by Buhler authorized persons only Only perform modifications maintenance or mounting described in this manual Only use original spare parts During maintenance regard all safety regulations and internal operation instructions 16 BX100020 05 2014 Art Nr 9032037 Bedienungs und Installationsanleitung Ww Installation and Operation Instruction a og e Nivotemp NT64 Nivovent NV74 easyfust EE EC LC 3 Installation and Connection Installation of the dev
29. ns done by the user Buhler Technologies GmbH can not be held responsible for any damage the performance limits given in the datasheets and in the installation and operation instruction are obeyed monitoring devices and safety devices are installed properly service and repair is carried out by B hler Technologies GmbH unless described in this manual only original spare parts are used This manual is part of the equipment The manufacturer keeps the right to modify specifications without advanced notice Keep this manual for later use The following warning signs and signal words are used in this manual disconnect from mains SEI Warning against Warning against hot wear respirator Warning against Warning against possible hazardous situation explosive atmospheres A electrical voltage surface Warning against Gs wear face respiration of toxic gases protection Warning against acid A A and corrosive L8 wear gloves substances Signal words for warnings Signal word for important information to the product Signal word for a hazardous situation with low risk resulting in damage to the device or the property or minor or medium injuries if not avoided Signal word for a hazardous situation with medium risk possibly resulting in severe injuries or death if not avoided Signal word for an imminent danger with high risk resulting in severe injuries or death if
30. nsmitter KT Temperature transmitter F hlerelement Messwiderstand Pt100 DIN EN 60751 Klasse B Class B sensor element resistor Messbereich 0 100 C 32 F 212 F measuring range Betriebsspannung Us 10 30 V DC operating voltage Us Ausgang 4 20 mA output B rde Ug 7 5 V 0 02 A load 26 BX100020 05 2014 Art Nr 9032037 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT64 Nivovent NV74 7 5 Abmessungen easyfust 7 5 Dimensions K neren 2 amp NT64 NV74 vs Verschmutzungsanzeige clogging indicator S 2 ha nn gt 4 mH cs NBR Dichtung a Gl Korkdichtung 2 5 NBR gasket Gl cork gasket 5 es BFA e Rand Bef lladapter gt gt 4 J T filling adapter ES re EN Bs o E S o g 2 _ Gl Korkdichtung T Gl cork gasket Go 2 ei ee q 11 Ko e t 90 2 nn Fer 8 wu re 523 I U N S erster Kontakt h 2 52 i first contact bel Z o 9 Q Vi Q SS 5S I SSR 4 Zo 3 I 5 Schwallschutzrohr na E S SI o mit Zentrierscheibe 5 5 E und Bef lladapter letzter 250 MS stilling tube with 860 3 VA u support ring and i L 44 filling adapter last 4 Do contact d letzter Kontakt last con
31. nststoffschrauben an den Kontakten l sen und neu positionieren cm Skala auf der R ckseite der Kontaktleiste Mindestabstand 40 mm gt Ggf Kontaktfunktion durch Drehen um 180 ndern gt Die Kunststoffschrauben zur Kontaktbefestigung handfest anziehen gt Kontaktleiste wieder in das Schutzrohr schieben gt Adapterstecker wieder richtig herum auf die Kontaktleiste aufstecken Die Markierungen am Adapterflansch und an der Kontaktleiste m ssen bereinander liegen gt Flanschdeckel inkl Dichtung befestigen gt Filterbeh lter befestigen Filtereinsatz einsetzen und Filterdeckel anschrauben Beispiel Filterdeckel mit De Or ung optional Temperatur i Flanschdeckel und R en un kontakt TK oder Pt100 Niveaukontakte So Beispiel e Steckverbindung M3 mit Steckersockel Kunststoff 7 schrauben Kontaktleiste Flansch Filterelement 10 BX100020 05 2014 Art Nr 9032037 Bedienungs und Installationsanleitung Ww Installation and Operation Instruction a og e Nivotemp NT64 Nivovent NV74 easyfust LEXUI AILEY 3 2 Nachtragliche Montage eines Temperaturfuhlers Bei Bedarf kann der Temperaturf hler nachger stet werden Wenden Sie sich in diesem Fall an unseren Service oder Ihre lokale Vertretung Halten Sie dazu bitte die Daten des Typenschildes bereit 4 Wartung Das Ger t arbeitet wartungsfrei Nur NV74 Das Filterelement muss bei Bedarf mindestens 1x j hrlich gewechselt werden In
32. r WE HI HR HM WR uf ay WU sl D I WU aft D aft WE vU D vu WI U U D D a a The switching logic assumes that the level switch is installed in an empty vessel implicating that the operating position is reached after filling the vessel The reference for the switching point is set to the middle of the EASYJUST level contact BX100020 05 2014 Art Nr 9032037 19 Bedienungs und Installationsanleitung Installation and Operation Instruction Nivotemp NT64 Nivovent NV74 easyyust NT64 gt Disconnect the device from the mains supply gt Pull the connector off gt Unscrew the connector base and carefully pull out the punched strip with adapter connector gt Remove the plastic screws from the contact housing and reposition the housing Use the cm scale on the back of the strip Regard the minimum distance 40 mm gt If necessary change the contact function gt Tighten the plastic screws hand tight gt Insert the contact strip into the tube and remount the connector base option temperature contact TK Pt100 or 4 20 mA output example level contacts Bu connector M3 immersion tube with connector socket j contact board flange adapter connector Plastic H screws NV74 gt Disconnect the device from the mains supply gt Remove filter cover and filter element gt Unscrew the fixing screws and remove the filter housing gt Remove the flange cover and gasket gt Pull the adapter con
33. reuzen Condition of aggregation please check Fl ssig Liquid Fest Solid Pulvrig Powdery Gasf rmig Gaseous Folgende Warnhinweise sind zu beachten bitte ankreuzen The following safety advices must be obeyed please check Explosiv Giftig T dlich Entz ndliche Stoffe Brandf rdernd Explosives Acute toxicity Flammable Oxidizing Komprimierte Gase Gesundheitsgef hrdend Gesundheitssch dlich Umweltgef hrdend Gas under pressure Irritant toxicity Health hazard Environmental hazard Bitte legen Sie ein aktuelles Datenblatt des Gefahrenstoffes bei Please include the current material safety data sheet of the hazardous material Angaben zum Absender Information about the dispatcher Firma Company Anschrift Address Ansprechpartner Contact person Abteilung Division E Mail Tel Phone Fax Unterschrift Ort Datum Stempel Location date Signature Stamp Buhler Technologies GmbH D 40880 Ratingen Harkortstr 29 Tel 49 0 2102 4989 0 Fax 49 0 2102 4989 20 e mail service buehler technologies com Internet www buehler technologies com
34. tact oO 9 E 2 B ii I Flanschbild Flange nach DIN 24557 Teil 2 according to DIN 24557 Part 2 BX100020 05 2014 Art Nr 9032037 27 EG Konformitatserklarung Ka EC declaration of conformity BUMPERS TECHNOLOGIES Hiermit erklaren wir dass die nachfolgenden Produkte den wesentlichen Anforderungen der folgenden EG Richtlinie in ihrer aktuellen Fassung entsprechen Herewith we declare that the following products correspond to the essential requirements of the following EC directive in its actual version 2004 108 EG EMV EMC Produkte products Niveauschalter und geber Level switches and gauges Typ en type s Nivotemp 61D 63 64 64D 67XP MD M XP Nivovent 71D 73 74 74D 77XP Zur Beurteilung der Konformit t wurden folgende harmonisierte Normen in aktueller Fassung herangezogen The following harmonized standards in actual revision have been used e EN 61326 1 Elektrische Mess Steuer Regel und Laborger te EMV Anforderungen Teil 1 Allgemeine Anforderungen Dokumentationsverantwortlicher f r diese Konformit tserkl rung ist der Unterzeichnende mit Anschrift am Firmensitz The person authorised to compile the technical file is the one that has undersigned and is located at the company s address Ratingen den 09 Juni 2010 ZI Stefan Eschweiler Technischer Leiter technical manager B hler Technologies GmbH Harkortstr 29 D 40880 Ratin
35. th gold plated contacts The colours are used for the coding of the different contacts and assure the allocation of the connector s assignments The colour coded housings allows easy assignment to the respective connector pins The contacts function falling opener fO or falling closer fC is determined by 180 rotation on the printed circuit board 1 2 Temperature Control Option An adjusted temperature switch bi metal NO or NC a Pt 100 RTD or a 4 20 mA transmitter is fixed at the lower end of the printed circuit board 1 3 Intended Use All types of devices are designed for industrial applications only They are not designed as safety devices They must not be used if in case of failure or malfunction safety or health of persons is affected The device is not suitable for use in hazardous areas with potentially explosive atmosphere 14 BX100020 05 2014 Art Nr 9032037 Bedienungs und Installationsanleitung Ww Installation and Operation Instruction a og e Nivotemp NT64 Nivovent NV74 easyfust EE 2 Important advice Please check prior to installation of the device that the technical data matches the application parameters Check that the delivery is complete as well Operation of the device is only valid if the product is used under the conditions described in the installation and operation instruction the intended application according to the type plate and the intended use In case of unauthorized modificatio
36. uschaltpunkt befindet sich in der Mitte des EASYJUST Niveaukontaktes BX100020 05 2014 Art Nr 9032037 9 Bedienungs und Installationsanleitung WW Installation and Operation Instruction E og e Nivotemp NT64 Nivovent NV74 easyyust PEXUT PALLETS NT64 gt Spannungszuf hrung unterbrechen gt Steckverbindungen l sen gt Steckersockel abschrauben und zusammen mit dem Adapterstecker und der Kontaktleiste vorsichtig nach oben herausziehen gt Die Kunststoffschrauben an den Kontakten l sen und neu positionieren cm Skala auf der R ckseite der Kontaktleiste Mindestabstand 40 mm gt Got Kontaktfunktion durch Drehen um 180 ndern Die Kunststoffschrauben zur Kontaktbefestigung handfest anziehen gt Kontaktleiste wieder in das Schutzrohr schieben und Steckersockel aufschrauben WV optional Temperaturkontakt TK Pt100 oder 4 20 mA Ausgang F000259X Niveaukontakte Beispiel Steckverbindung M3 Le SECH mit Steckersockel Schaltrohr Flansch Schwimmer Adapterstecker Kunststoff Kontaktleiste schrauben NV74 gt Spannungszuf hrung unterbrechen gt Filterdeckel abschrauben und Filterelement herausnehmen gt Die Befestigungsschrauben l sen und Filterbeh lter entfernen gt Die Schrauben des Flanschdeckels l sen und Deckel mit Deckeldichtung abnehmen gt Den Adapterstecker von der Kontaktleiste abziehen und Kontaktleiste vorsichtig nach oben herausnehmen gt Die Ku
37. zeinrichtungen verwendet werden und vorgeschriebene Wartungsarbeiten durchgef hrt werden bei der Entsorgung die gesetzlichen Regelungen beachtet werden Wartung Reparatur Reparaturen an den Betriebsmitteln d rfen nur von B hler autorisiertem Personal ausgef hrt werden Nur Umbau Wartungs oder Montagearbeiten ausf hren die in dieser Bedienungs und Installationsanleitung beschrieben sind Nur Original Ersatzteile verwenden Bei Durchf hrung von Wartungsarbeiten jeglicher Art m ssen die relevanten Sicherheits und Betriebsbestimmungen beachtet werden 6 BX100020 05 2014 Art Nr 9032037 Bedienungs und Installationsanleitung Ww Installation and Operation Instruction a og e Nivotemp NT64 Nivovent NV74 easyfust EE ES W 3 Aufbauen und Anschlie en Die Montage und der Anschluss d rfen nur von entsprechend ausgebildeten Fachleuten ausgef hrt werden Die jeweils geltenden Sicherheitsvorschriften des Einsatzortes sind einzuhalten GEFAHR Giftige tzende Gase Fl ssigkeiten Sch tzen Sie sich bei allen Arbeiten vor giftigen tzenden Gasen Fl ssigkeiten Tragen Sie die entsprechende Schutzausr stung Zum direkten Tankaufbau wird das Schaltrohr in die daf r vorgesehene Bohrung nach DIN 24557 Teil2 mit der Gl Korkdichtung eingesetzt Die Befestigung erfolgt mit den beiliegenden Schrauben und Dichtungen am DIN Flansch Der Schwimmer muss sich frei bewegen und gen gend Abstand zur Beh lterwand un
Download Pdf Manuals
Related Search
Related Contents
MANUALE D`USO TOSATRICE PROFESSIONALE 1.02 english - Elektroninės technologijos 取扱説明書 (BioAssist IEC) Samsung NP-X11 Manuel de l'utilisateur Samsung Climatizzatore AR4500 12000Btu/h, Classe A++/A; 19 dB User Manual SD-8 Signaldistributor for Pixelscreen/Mesh Manual de instruções Copyright © All rights reserved.