Home

ATCA-7360 Safety Notes Summary - Artesyn Embedded Technologies

image

Contents

1. Injuries or Short Circuits Blade or power supply In case the ORing diodes of the blade fail the blade may trigger a short circuit between input line A and input line B so that line A remains powered even if it is disconnected from the power supply circuit and vice versa To avoid damage or injuries always check that there is no more voltage on the line that has been disconnected before continuing your work Switch Settings Blade Malfunction Switches marked as reserved might carry production related functions and can cause the blade to malfunction if their setting is changed Therefore do not change settings of switches marked as reserved The setting of switches which are not marked as reserved has to be checked and changed before blade installation ATCA 7360 Installation and Use 6806800 07R 7 Safety Notes Blade Damage Setting resetting the switches during operation can cause blade damage Therefore check and change switch settings before you install the blade Battery Blade Damage Wrong battery installation may result in hazardous explosion and blade damage Therefore always use the same type of Lithium battery as is installed and make sure the battery is installed as described in this manual Environment Always dispose of used blades system components and RTMs according to your country s legislation and manufacturer s instructions 8 ATCA 7360 Installation and Use 6806800J07R Sicherheitshinweise
2. changes from time to time in the content hereof without obligation of Artesyn to notify any person of such revision or changes Electronic versions of this material may be read online downloaded for personal use or referenced in another document as a URL to an Artesyn website The text itself may not be published commercially in print or electronic form edited translated or otherwise altered without the permission of Artesyn It is possible that this publication may contain reference to or information about Artesyn products machines and programs programming or services that are not available in your country Such references or information must not be construed to mean that Artesyn intends to announce such Artesyn products programming or services in your country Limited and Restricted Rights Legend If the documentation contained herein is supplied directly or indirectly to the U S Government the following notice shall apply unless otherwise agreed to in writing by Artesyn Use duplication or disclosure by the Government is subject to restrictions as set forth in subparagraph b 3 of the Rights in Technical Data clause at DFARS 252 227 7013 Nov 1995 and of the Rights in Noncommercial Computer Software and Documentation clause at DFARS 252 227 7014 Jun 1995 Contact Address Artesyn Embedded Technologies Artesyn Embedded Technologies Marketing Communications Lilienthalstr 17 19 2900 S Diablo Way Suite 190 85579 Neubiber
3. complexity of this product and its various uses we do not guarantee that the given information is complete If you need additional information ask your Artesyn representative The product has been designed to meet the standard industrial safety requirements It must not be used except in its specific area of office telecommunication industry and industrial control Only personnel trained by Artesyn or persons qualified in electronics or electrical engineering are authorized to install remove or maintain the product The information given in this manual is meant to complete the knowledge of a specialist and must not be used as replacement for qualified personnel Keep away from live circuits inside the equipment Operating personnel must not remove equipment covers Only factory authorized service personnel or other qualified service personnel may remove equipment covers for internal subassembly or component replacement or any internal adjustment Do not install substitute parts or perform any unauthorized modification of the equipment or the warranty may be voided Contact your local Artesyn representative for service and repair to make sure that all safety features are maintained The blade has been tested in a standard Artesyn system and found to comply with the limits for a Class A digital device in this system pursuant to part 15 of the FCC Rules EN 55022 Class A respectively These limits are designed to provide reasonable protection
4. esse Dieses Kapitel enth lt Hinweise die potentiell gef hrlichen Prozeduren innerhalb dieses Handbuchs vorrangestellt sind Beachten Sie unbedingt in allen Phasen des Betriebs der Wartung und der Reparatur des Systems die Anweisungen die diesen Hinweisen enthalten sind Sie sollten au erdem alle anderen Vorsichtsma nahmen treffen die f r den Betrieb des Produktes innerhalb Ihrer Betriebsumgebung notwendig sind Wenn Sie diese Vorsichtsma nahmen oder Sicherheitshinweise die an anderer Stelle diese Handbuchs enthalten sind nicht beachten kann das Verletzungen oder Sch den am Produkt zur Folge haben Artesyn Embedded Technologies ist darauf bedacht alle notwendigen Informationen zum Einbau und zum Umgang mit dem Produkt in diesem Handbuch bereit zu stellen Da es sich jedoch um ein komplexes Produkt mit vielf ltigen Einsatzm glichkeiten handelt k nnen wir die Vollst ndigkeit der im Handbuch enthaltenen Informationen nicht garantieren Falls Sie weitere Informationen ben tigen sollten wenden Sie sich bitte an die f r Sie zust ndige Gesch ftsstelle von Artesyn Das System erf llt die f r die Industrie geforderten Sicherheitsvorschriften und darf ausschlie lich f r Anwendungen in der Telekommunikationsindustrie und im Zusammenhang mit Industriesteuerungen verwendet werden Einbau Wartung und Betrieb d rfen nur von durch Artesyn ausgebildeter oder im Bereich Elektronik oder Elektrotechnik qualifiziertem Personal durchgef hr
5. intra building port s of the equipment or subassembly is suitable for connection to intra building or unexposed wiring or cabling only The intra building port s of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the outside plant OSP or its wiring These interfaces are designed for use as intra building interfaces only Type 2 or Type 4 ports as described in GR 1089 and require isolation from the exposed OSP cabling The addition of primary protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring The intra building port s of the equipment or subassembly must use shielded intra building cabling wiring that is grounded at both ends 6 ATCA 7360 Installation and Use 6806800 07R Safety Notes Operation Blade Damage Blade surface High humidity and condensation on the blade surface causes short circuits Do not operate the blade outside the specified environmental limits Make sure the blade is completely dry and there is no moisture on any surface before applying power Blade Overheating and Blade Damage Operating the blade without forced air cooling may lead to blade overheating and thus blade damage When operating the blade make sure that forced air cooling is available in the shelf When operating the blade in areas of electromagnetic radiation ensure that the blade is bolted on the system and the system is shielded by enclosure
6. ude oder unbelichteten Verdrahtung oder Verkabelung nur Die intra Geb ude Port s des Ger ts oder Baugruppe muss nicht metallisch mit Schnittstellen die an der Au enanlage OSP oder dessen Verkabelung anschlie en angeschlossen werden Diese Schnittstellen sind f r die Verwendung als intra Geb ude Schnittstellen nur entworfen Typ 2 oder Typ 4 Ports wie in GR 1089 beschrieben und erfordern Isolierung von der freiliegenden OSP Verkabelung Die Zugabe von prim ren Schutz nicht ausreichenden Schutz um diese Schnittstellen metallisch mit OSP Verdrahtung verbinden Die intra Geb ude Port s des Ger tes oder einer Unterbaugruppe m ssen abgeschirmte innerGeb udeVerkabelung Verdrahtung die an beiden Enden geerdet ist zu verwenden Besch digung des Blades Hohe Luftfeuchtigkeit und Kondensat auf der Oberfl che des Blades k nnen zu Kurzschl ssen f hren Betreiben Sie das Blade nur innerhalb der angegebenen Grenzwerte f r die relative Luftfeuchtigkeit und Temperatur Stellen Sie vor dem Einschalten des Stroms sicher dass sich auf dem Blade kein Kondensat befindet berhitzung und Besch digung des Blades Betreiben Sie das Blade ohne Zwangsbel ftung kann das Blade berhitzt und schlie lich besch digt werden Bevor Sie das Blade betreiben m ssen Sie sicher stellen dass das Shelf ber eine Zwangsk hlung verf gt Wenn Sie das Blade in Gebieten mit starker elektromagnetischer Strahlung betreiben stellen Sie sicher dass
7. ATCA 7360 Safety Notes Summary P N 6806800J11F September 2015 EEE R m eA z arma E Law EMBEDDED TECHNOLO E z 0 ra E Copyright 2015 Artesyn Embedded Technologies Inc All rights reserved Trademarks Artesyn Embedded Technologies Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies Inc 2014 2015 Artesyn Embedded Technologies Inc All other product or service names are the property of their respective owners Intel is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries Java and all other Java based marks are trademarks or registered trademarks of Oracle America Inc in the U S and other countries Microsoft Windows and Windows Me are registered trademarks of Microsoft Corporation and Windows XP is a trademark of Microsoft Corporation PICMG CompactPCl AdvancedTCA and the PICMG CompactPCI and AdvancedTCA logos are registered trademarks of the PCI Industrial Computer Manufacturers Group UNIX is a registered trademark of The Open Group in the United States and other countries Notice While reasonable efforts have been made to assure the accuracy of this document Artesyn assumes no liability resulting from any omissions in this document or from the use of the information obtained therein Artesyn reserves the right to revise this document and to make
8. against harmful interference when the system is operated in a commercial environment Safety Notes This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Interference VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions To ensure EMC protection use only shielded cables when connecting peripherals to assure that appropriate radio frequency emissions compliance is maintained Installed blades must have the face plates installed and all vacant slots in the shelf must be covered The blade generates and uses radio frequency energy and if not installed properly and used in accordance with this guide may cause harmful interference to radio communications Operating the system in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Installation Damage of Circuits Electrostatic discharge and incorrect blade installation and removal can damage circuits or shorten their life Before touching the blade or electronic components make sure that you are working in an ESD safe environment Data Loss Removing the blade with the blue LED still blinking causes data loss Wait until the blue LED is permanently illuminated before removing the blade System Damage WARNING The
9. das Blade mit dem System verschraubt ist und das System durch ein Geh use abgeschirmt wird ATCA 7360 Installation and Use 6806800 07R 11 Sicherheitshinweise Verletzungen oder Kurzschliisse Blade oder Stromversorgung Falls die ORing Dioden des Blades durchbrennen kann das Blade einen Kurzschluss zwischen den Eingangsleitungen A und B verursachen In diesem Fall ist Leitung A immer noch unter Spannung auch wenn sie vom Versorgungskreislauf getrennt ist und umgekehrt Pr fen Sie deshalb immer ob die Leitung spannunggsfrei ist bevor Sie Ihre Arbeit fortsetzen um Sch den oder Verletzungen zu vermeiden Schaltereinstellungen Batterie 12 Fehlfunktion des Blades Schalter die mit Reserved gekennzeichnet sind k nnen mit produktionsrelevanten Funktionen belegt sein Das ndern dieser Schalter kann im normalen Betrieb St rungen ausl sen Verstellen Sie nur solche Schalter die nicht mit Reserved gekennzeichnet sind Pr fen und ndern Sie die Einstellungen der nicht mit Reserved gekennzeichneten Schalter bevor Sie das Blade installieren Besch digung der Blade Das Verstellen von Schaltern w hrend des laufenden Betriebes kann zur Besch digung des Blades f hren Pr fen und ndern Sie die Schaltereinstellungen bevor Sie das Blade installieren Besch digung des Blades Ein unsachgem er Einbau der Batterie kann gef hrliche Explosionen und Besch digungen des Blades zur Folge haben Verwenden Sie desha
10. g Munich Tempe Arizona 85282 Germany About this Manual sis Summary of Changes This manual has been revised and replaces all prior editions Order No Date Description 6806800 11F September 2015 Updated GR 1089 related information in the sections Installation on page 6 and Installation on page 10 6806300 11E June 2014 Rebranded to Artesyn template 6806800J11D March 2012 Updated the sections EMC on page 5 Installation on page 6 EMV on page 10 and Installation on page 10 6806800J11C January 2010 GA version 6806800J11B November 2009 EA version 6806800 11A November 2009 First version ATCA 7360 Installation and Use 6806800 07R 3 About this Manual m 4 ATCA 7360 Installation and Use 6806800 07R Safety Notes EMC ATCA 7360 Installation and Use 6806800 07R This section provides warnings that precede potentially dangerous procedures throughout this manual Instructions contained in the warnings must be followed during all phases of operation service and repair of this equipment You should also employ all other safety precautions necessary for the operation of the equipment in your operating environment Failure to comply with these precautions or with specific warnings elsewhere in this manual could result in personal injury or damage to the equipment Artesyn Embedded Technologies intends to provide all necessary information to install and handle the product in this manual Because of the
11. lb nur den Batterietyp der auch bereits eingesetzt wurde und befolgen Sie die Installationsanleitung ATCA 7360 Installation and Use 6806800 07R Sicherheitshinweise pm EEEE y Umweltschutz Entsorgen Sie alte Batterien und oder Blades Systemkomponenten RTMs stets gem der in Ihrem Land g ltigen Gesetzgebung und den Empfehlungen des Herstellers ATCA 7360 Installation and Use 6806800J07R 13 Sicherheitshinweise eee rk 14 ATCA 7360 Installation and Use 6806800J07R A mS YN z wm E ou F EMBEDDED TECHNOLOGIES Artesyn Embedded Technologies Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies Inc All other product or service names are the property of their respective owners 2015 Artesyn Embedded Technologies Inc
12. t werden Die in diesem Handbuch enthaltenen Informationen dienen ausschlie lich dazu das Wissen von Fachpersonal zu erg nzen k nnen dieses jedoch nicht ersetzen Halten Sie sich von stromf hrenden Leitungen innerhalb des Produktes fern Entfernen Sie auf keinen Fall Abdeckungen am Produkt Nur werksseitig zugelassenes Wartungspersonal oder anderweitig qualifiziertes Wartungspersonal darf Abdeckungen entfernen um Komponenten zu ersetzen oder andere Anpassungen vorzunehmen Installieren Sie keine Ersatzteile oder f hren Sie keine unerlaubten Ver nderungen am Produkt durch sonst verf llt die Garantie Wenden Sie sich f r Wartung oder Reparatur bitte an die f r Sie zust ndige Gesch ftsstelle von Artesyn So stellen Sie sicher dass alle sicherheitsrelevanten Aspekte beachtet werden ATCA 7360 Installation and Use 6806800 07R 9 Sicherheitshinweise EMV Das Blade wurde in einem Artesyn Standardsystem getestet Es erf llt die f r digitale Ger te der Klasse A g ltigen Grenzwerte in einem solchen System gem den FCC Richtlinien Abschnitt 15 bzw EN 55022 Klasse A Diese Grenzwerte sollen einen angemessenen Schutz vor St rstrahlung beim Betrieb des Blades in Gewerbe sowie Industriegebieten gew hrleisten Das Blade arbeitet im Hochfrequenzbereich und erzeugt St rstrahlung Bei unsachgem em Einbau und anderem als in diesem Handbuch beschriebenen Betrieb k nnen St rungen im Hochfrequenzbereich auftreten Benutzen Sie z
13. um Anschlie en von Peripherieger ten ausschlie lich abgeschirmte Kabel So stellen Sie sicher dass ausreichend Schutz vor St rstrahlung vorhanden ist Die Blades m ssen mit der Frontblende installiert und alle freien Steckpl tze m ssen mit Blindblenden abgedeckt sein Warnung Dies ist eine Einrichtung der Klasse A Diese Einrichtung kann im Wohnbereich Funkst rungen verursachen In diesem Fall kann vom Betreiber verlangt werden angemessene Ma nahmen durchzuf hren Installation 10 Besch digung von Schaltkreisen Elektrostatische Entladung und unsachgem er Ein und Ausbau von Blades kann Schaltkreise besch digen oder ihre Lebensdauer verk rzen Bevor Sie Blades oder elektronische Komponenten ber hren vergewissern Sie sich da Sie in einem ESD gesch tzten Bereich arbeiten Datenverlust Wenn Sie das Blade aus dem Shelf herausziehen und die blaue LED blinkt noch gehen Daten verloren Warten Sie bis die blaue LED durchgehend leuchtet bevor Sie das Blade herausziehen ATCA 7360 Installation and Use 6806800 07R Sicherheitshinweise Betrieb Besch digung des Blades und von Zusatzmodulen Fehlerhafte Installation von Zusatzmodulen kann zur Besch digung des Blades und der Zusatzmodule fiihren Lesen Sie daher vor der Installation von Zusatzmodulen die zugeh rige Dokumentation Besch digung des Systems Warnung Die intra Geb ude Port s des Ger ts oder Baugruppe ist f r den Anschluss an den inner Geb