1. AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 TECHNOLOGIES 2 1 Indications of risk Definitions for warnings Signal word for important information to the product Signal word for a hazardous situation with low risk resulting in damaged to the device or the property or minor or medium injuries if not avoided Signal word for a hazardous situation with medium risk possibly resulting in severe injuries or death if not avoided DANGER Signal word for an imminent danger with high risk resulting in severe injuries or death if not avoided Warning against possible explosive disconnect from mains atmospheres Warning against hazardous situation Warning against Warning against hot wear respirator electrical voltage surface p Warning against respiration of toxic wear face protection gases Warning against acid and corrosive wear gloves substances Installation of the device shall be performed by trained staff only familiar with the safety requirements and risks Check all relevant safety regulations and technical indications for the specific installation place Prevent failures and protect persons against injuries and the device against damage The person responsible for the system must secure that safety and operation instructions are accessible and followed local safety regulations and standards are obeyed performance data and installation specifications are regarded
2. safety devices are installed and recommended maintenance is performed national regulations for disposal of electrical equipment are obeyed Maintenance and repair Repairs on the device must be carried out by Buhler authorized persons only Only perform modifications maintenance or mounting described in this manual Only use original spare parts During maintenance regard all safety regulations and internal operation instructions BX410011 12 2011 Art Nr 90 310 46 11 Bedienungs und Installationsanleitung Installation and Operation Instruction Analysenfilter Sample gas filter AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 Ww 4207 AR TECHNOLOGIES DANGER Toxic and corrosive gases Sample gas can be hazardous Take care that the gas is exhausted in a place where no persons are in danger Before maintenance turn off the gas supply and make sure that it cannot be turned on unintentionally Protect yourself during maintenance against toxic corrosive gases Use gloves respirator and face protector under certain circumstances DANGER Application in explosive atmosphere Combustible gases and dust may inflame or explode Avoid the following hazardous situations Electrostatic charge Clean plastic parts and labels with damp cloth only Connect metallic covers to ground PE Spark formation Protect the equipment against being hit Flashover from process Install a flame
3. ar TECHNOLOGIES Bedienungs und Installationsanleitung Installation and Operation Instruction Analysenfilter Sample gas filter AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 Lesen Sie die Bedienungsanleitung vor dem Gebrauch des Gerates grundlich durch insbesondere die Hinweise unter Gliederungspunkt 2 Andernfalls k nnten Gesundheits oder Sachsch den auftreten Die B hler Technologies GmbH haftet nicht bei eigenm chtigen nderungen des Ger tes oder f r unsachgem en Gebrauch Read this instruction carefully prior to installation and or use Pay attention particularly to all advises and safety instructions to prevent injuries B hler Technologies GmbH can not be held responsible for misusing the product or unreliable function due to unauthorised modifications BX410011 12 2011 Art Nr 90 310 46 B hler Technologies GmbH Harkortstr 29 D 40880 Ratingen N Tel 49 0 21 02 49 89 0 Fax 49 0 21 02 49 89 20 Q Internet www buehler technologies com Email analyse buehler technologies com Bedienungs und Installationsanleitung Installation and Operation Instruction Analysenfilter Sample gas filter Ww 420 aR AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 TECHNOLOGIES Inhaltsverzeichnis Seite 1 PVE UN ssa orccdateceir ernie oc ew stice ce neste ce wience veipaiec eaewinsieaesn eases oe awaniea caw eseeseewansce sen nsseeuciecarsneseceeeaweneck 3 2 HINWeiSe a a
4. 0 21 02 49 89 0 Fax 49 0 21 02 49 89 20 Email buehler buehler ratingen com HX 410002 Dekontaminierungserklarung pa sae Declaration of Contamination status ALA G ltig ab valid since 2011 05 01 Revision 0 ersetzt Rev replaces Rev Die gesetzlichen Vorschriften schreiben vor dass Sie uns die Dekontaminierungserklarung ausgefullt und unterschrieben zuruck zu senden haben Die Angaben dienen zum Schutz unserer Mitarbeiter Bringen Sie die Bescheinigung an der Verpackung an Ansonsten ist eine Bearbeitung Ihres Reparaturauftrages nicht m glich Legal regulations prescribe that you have to fill in and sign the Declaration of Contamination status and send it back This information is used to protect our employees Please attach the declaration to the packing Otherwise your repair order cannot be processed Gerat Serien Nr Device Serial no Rucksendegrund Reason for return Ich best tige hiermit dass das oben spezifizierte Ger t ordnungsgem gereinigt und dekontaminiert wurde und keinerlei Gefahren im Umgang mit dem Produkt bestehen herewith declare that the device as specified above has been properly cleaned and decontaminated and that there are no risks present when dealing with the device Ansonsten ist die m gliche Gef hrdung genauer zu beschreiben In other cases please describe the hazards in detail Aggregatzustand bitte ankreuzen Condition of aggregation pl
5. und Installationsanleitung Installation and Operation Instruction h f Analysenfilter Sample gas filter PU MERA AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 TECHNOLOGIES 5 Installation and connection The filter should be mounted in such a way to assure easy replacing of the filter element see chapter 13 for the procedure Be aware that the filter may be damaged if is mounted outside a housings shape In this case take precautions against damage 5 __ section B B Middle junction l in out A000020E AGF PV 30 5 1 Connecting the gas ports Insert the fittings G 14 or NPT 1 4 properly into the threads The flow direction is indicated by an arrow marked on top of the filter s head The head may be turned to change the in against the outlet only inlet for the RAV PV 30 Please make sure that you have a version with G thread or NPT threads The NPT threads have an attached to the item number on the label 9 2 Inserting a bypass or a moisture detector not with AGF T 30 senseless with RAV PV 30 The filter head contains a third inner thread G 1 4 on top which is plugged on delivery Take off the plug and insert the fitting or the moisture sensor type FF Pay attention to leak tightness 6 Replacing the filter element Installation and maintenance of the device shall be performed by trained staff only familiar with the safety requirements and risks The dev
6. durch Fachpersonal installiert werden die einschl gigen Sicherheitsvorschriften sind zwingend zu beachten Beachten sie auch die Sicherheitshinweise in der zugeh rigen Bedienungsanleitung Die Produkte sind f r den Einsatz in explosionsgef hrdeten Bereichen der Zone 1 Gruppe IIB geeignet Sample gas filter can be used for gas filtration in gas analysis systems Inflammable gases and flammable gases only temporary explosive in normal operation zone 1 depending on the used filter element group IIB or IIC can led through the sample gas filter They have to be installed by trained personnel All safety regulations have to be fulfilled Note also the indications in the associated Installation and Operation Instruction The sample gas filter can be used in zone 1 group IIB Zur Beurteilung der Erzeugnisse wurden folgende Normen in der aktuellen Fassung herangezogen The following harmonized standards in actual revision have been used EN 1127 1 Explosionsf hige Atmosph ren Explosionsschutz Teill Grundlagen und Methodik EN 13463 1 Nichtelektrische Ger te f r den Einsatz in explosionsgef hrdeten Bereichen Teil 1 EN13463 5 Nichtelektrische Ger te f r den Einsatz in explosionsgef hrdeten Bereichen Teil 5 Ratingen den 01 03 2005 G R Biller Stefan Eschweiler Gesch ftsf hrer Managing Director Technischer Leiter technical manager 01 03 05 B hler Mess und Regeltechnik GmbH Harkortstr 29 D 40880 Ratingen Tel 49
7. 0 RAF PV 30 ADF PV 30 TECHNOLOGIES 2 1 Gefahrenhinweise Begriffsbestimmungen fur Warnhinweise HINWEIS Signalwort f r wichtige Information zum Produkt auf die im besonderen Ma e aufmerksam gemacht werden soll Signalwort zur Kennzeichnung einer Gef hrdung mit geringem Risiko die zu einem Sach schaden oder leichten bis mittelschweren K rperverletzungen f hren kann wenn sie nicht Signalwort zur Kennzeichnung einer Gef hrdung mit mittlerem Risiko die m glicherweise Tod oder schwere K rperverletzungen zur Folge hat wenn sie nicht vermieden wird GEFAHR Signalwort zur Kennzeichnung einer Gef hrdung mit hohem Risiko die unmittelbar Tod oder schwere K rperverletzung zur Folge hat wenn sie nicht vermieden wird Warnung vor explosions gef hrdeten Netzstecker ziehen Bereichen Warnung vor einer allgemeinen Gefahr Warnung vor Warnung vor hei er elektrischer Spannung Oberfl che omsenlte Hagen Warnung vor dem Einatmen giftiger Gesichtsschutz tragen Gase Warnung vor tzenden Fl ssigkeiten Handschuhe tragen Das Ger t darf nur von Fachpersonal installiert werden Beachten Sie unbedingt die f r den Einbauort relevanten Sicherheitsvorschriften und allgemein g ltigen Regeln der Technik Beugen Sie St rungen vor und vermeiden Sie dadurch Personen und Sachsch den Der f r die Anlage Verantwortliche muss sicherstellen dass Sicherheitshinweise und Betriebsanleitungen verf gbar sind und eingehalten we
8. Please ship the device with suitable packing to Buhler Technologies GmbH Service Harkortstra e 29 40880 Ratingen Germany In Addition attach the filled in and signed Declaration of Decontamination status to the packing Otherwise your repair order cannot be processed The form can be requested by e mail to service buehler technologies com 7 1 Disposal Regard the local regulations for disposal of electric and electronic equipment 8 Attached documents Declaration according to directive 94 9 EC HX410002 Declaration of Contamination status BX410011 12 2011 Art Nr 90 310 46 17 Erklarung in Anlehnung an die Richtlinie 94 9 EG declaration according to directive 94 9 EG Hiermit erklaren wir dass die nachfolgenden Produkte den wesentlichen Anforderungen der Richtlinie 94 9 EG uber Explosionsschutz in ihrer aktuellen Fassung entsprechen Herewith we declare that the following products correspond to the essential requirements of the directive 94 9 EC about explosive atmospheres Produkte products Analysefilter Sample gas filter Typ type AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 Analysefilter sind zur Filterung von MeBgasen innerhalb von Gasanalysesystemen bestimmt Durch die Analysefilter k nnen nichtbrennbare Gase und brennbare Gase die im Normalbetrieb gelegentlich explosiv sein k nnen Zone 1 je nach Filterelement Gruppe IIB oder IIC geleitet werden Die Analysefilter d rfen nur
9. Schutzausr stung GEFAHR Einsatz in explosionsgefahrdeten Bereichen Brennbare Gase und Staub k nnen sich entz nden oder explodieren Vermeiden Sie die folgenden Gefahrenquellen Elektrostatische Aufladung Funkenbildung Reinigen Sie Geh useteile aus Kunststoff und Aufkleber nur mit einem feuchten Tuch Metallische Geh use m ssen mit Erdpotential PE leitend verbunden werden Funkenbildung Sch tzen Sie das Betriebsmittel ist vor externen Schlageinwirkungen Flammdurchschlag Installieren Sie bei Gefahr eines Flammdurchschlags aus dem Prozess eine Flammsperre Maximale Oberflachentemperatur Die maximale Oberflachentemperatur T ur des Betriebsmittels richtet sich nach der Mediumtemperatur T mea ES gilt T sure lt T mea Zundtemperaturen Beachten Sie die ZUndtemperaturen explosiver Gase sowie maximal zul ssige Oberflachentemperaturen T ur gem zutreffender Normen Gasaustritt Lebens und Explosionsgefahr durch Gasaustritt bei nicht bestimmungsgemakem Betrieb und bei Wartungsarbeiten m glich Bruchgefahr Vergiftung Verletzung durch Austreten giftiger oder explosiver Gase m glich Sch tzen Sie das Betriebsmittel ist vor externen Schlageinwirkungen Sch tzen Sie das Ger t vor fallenden Gegenst nden BX410011 12 2011 Art Nr 90 310 46 5 Bedienungs und Installationsanleitung Installation and Operation Instruction vw Analysenfilter Sample gas fil
10. an nee een een ren Eee een ee 3 2 1 Gefahrenhinweise 2 cccccececcecececceccccacecececcececceceacaceceaceueaeuceaeaceneacsueesueneaueuecesueaeceeneaestecesueeaesneas 4 3 PIOQUKIDESCHLEIDUNG sses EEEE 6 4 Transport und Lagerungsvorschriften 22022200200020000000n0nn0n nun nun nun nun nun nun nun nun nn nn 7 5 Aufbauen und Anschlie en u0000000000000n0nannan nun ann an nun ann an nun ann un nun nn n ann an nnn an nun nnn an nun nun 7 5 1 BSASsanschlUsSe usa anstehen rennen ee re T 5 2 Anschluss eines Bypasses oder Feuchtef hlers cccccccccsececeeeeceeeeeeeeeae cess eeseeeeseseeseeeeseeesaeeess 8 6 Wechsel des Filterelementes ccccceeceeceeceeceneeneeneeneeneeneeneeneenneaneaneaneaneaneauenneaennesneaes 8 7 Instandsetzung und Entsorgung 22020020nnunnunnnnonnnnnnnnnun nun nun nun nn nnnnnnnnnn nun nennen 9 7 1 BFS OO UN IC een er ee een rege 9 8 Beigef gte Dokumente 2u02u0 00 nn0nnnnnnnunnunnunnun nun nun ann nun nun nun nun nun nun ann nn nnnn nun nun nun nenn 9 Contents Page 1 INEFOGUCEIO N ee ae ee re a re ee een re een 10 2 IMDOrlant QVCO asain irn nn ehe I ne Dun nn near Fun IE un En IE EIER TEE EEE IHREN 10 2 1 HAGICALIONS OF FISK ee a ee a ea in nee nee ernennen ee 11 3 Product description 2 00200200n00n00nnnunnunnunnn nun nun nun nun nn nun nun nun nun nun ann nn nun nun nun nun nnn nen 13 4 Transport and storing re
11. cs S2KU 41 01 01 40 F2L 41 02 00 50 2 pcs 41 01 01 50 F25L 41 01 01 20 2 pcs K AGF PV 30 A Coalescent filter with head made of PVDF Spare filter elements 12 57 C 49 32 001 12 57 C 49 32 002 1 pcs with PVDF cap for part no 4150699 for on screwing for part no 41506995 Maximum sample temperature is 100 C 212 F Maximum pressure is 4 bar 58 02 psi absolute BX410011 12 2011 Art Nr 90 310 46 13 Bedienungs und Installationsanleitung Installation and Operation Instruction Ww Analysenfilter Sample gas filter BUHERI AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 TECHNOLOGIES l HINWEIS Application in explosive atmosphere additional indications Depending on the used filter element inflammable gases and flammable gases only temporary explosive in normal operation zone 1 group IIB or IIC can also be led through the sample gas filter AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 note table 1 Filter element type applicable for gas group group IIC zone 1 F2 L S2ku group IIC zone 1 4 Transport and storing regulations The equipment should be only transported in the original case or in appropriate packing Protect the equipment against heat and humidity The filter must be stored in roofed dry and dust free room Temperature should be between 20 C and 60 C 4 F and 140 F 14 BX410011 12 2011 Art Nr 90 310 46 Bedienungs
12. ease check Fl ssig Liquid Fest Solid Pulvrig Powdery Gasf rmig Gaseous Folgende Warnhinweise sind zu beachten bitte ankreuzen The following safety advices must be obeyed please check Komprimierte Gase Gesundheitsgef hrdend Gesundheitssch dlich u Umweltgef hrdend Gas under pressure Irritant toxicity Health hazard Environmental hazard Bitte legen Sie ein aktuelles Datenblatt des Gefahrenstoffes bei Please include the current material safety data sheet of the hazardous material Angaben zum Absender Information about the dispatcher Firma Company Anschrift Address Ansprechpartner Contact person Abteilung Division E Mail Tel Phone Fax Unterschrift Ort Datum Stempel Location date Signature Stamp Buhler Technologies GmbH D 40880 Ratingen Harkortstr 29 Tel 49 0 2102 4989 0 Fax 49 0 2102 4989 20 e mail service buehler technologies com Internet www buehler technologies com
13. gulations u zu02un 0n2un0nnnnnnnnnnunnunnun nun nun nn nnnnnnnnnn nun nennen 14 5 Installation and connection u uu u0u0nnnnnnnnnnun nun nun nun nun nun nun nun nunnunnunnunnunn ann anna nun nun 15 5 1 Connecting the gas POT Eu nn ee 15 5 2 Inserting a bypass or a moisture detector 2 u0240020002000000000000nnn anno nnnnnnnn nen anne nnnn anne nennen 15 6 Repl c ng tTherflter lement run 15 7 Repair and CISD OS a zzcunus essen eaeetucutanstaceeesetanctanstadeeocetaaetancteceeeesteadtanstacseesctacctars 17 7 1 BIE OS Meee elected eee etek ee E En tts xeon Eee ee 17 8 Attached documents u0000000nnannnnnnnn nun ann nun nun nun nun nun nun nun nun nun nun nun nun nunn anna nunn anna nun nun 17 2 BX410011 12 2011 Art Nr 90 310 46 Bedienungs und Installationsanleitung Installation and Operation Instruction A Analysenfilter Sample gas filter BUHERI AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 TECHNOLOGIES 1 Einleitung Diese Bedienungs und Installationsanleitung gilt f r Analysefilter vom Typ AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 Alle Typen k nnen innerhalb eines Gasanalysesystems zur Filterung von Messgasen verwendet werden Welchen Typ Sie vor sich haben ersehen Sie aus dem Typenschild Auf diesem finden Sie neben der Auftragsnummer auch die Artikelnummer und Typbezeichnung Sofern f r einen Filtertyp Besonderhe
14. ice must be operated within its specifications All repairs must be carried out by Buhler authorised personnel only Only perform modifications servicing or mounting described in this manual Only use original spare parts Regard all relevant safety regulations and internal operating instructions during maintenance DANGER Electrical voltage Electrocution hazard Before any manipulation on the device disconnect the electrical equipment from mains power supply Make sure that the electrical equipment cannot be reconnected during repair or maintenance The wiring must be done by trained staff only Regard the correct mains voltage BX410011 12 2011 Art Nr 90 310 46 15 Bedienungs und Installationsanleitung Installation and Operation Instruction A Analysenfilter Sample gas filter PU MERA AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 TECHNOLOGIES DANGER The gas inside the filter condensate and used filter elements may be caustic or corrosive Before maintenance turn off the gas supply and make sure that it cannot be turned on unintentionally Rinse filter with air before opening Please exhaust sample gas to a safe place Protect yourself against toxic corrosive gas during maintenance Use gloves respirator and face protector under certain circumstances Gas leakage The filter should not be dismantled under pressure Do not use damaged parts again Procedure g
15. icherheits und Betriebsbestimmungen GEFAHR Elektrische Spannung Gefahr eines elektrischen Schlages Trennen Sie das Gerat bei allen Wartungsarbeiten vom Netz Sichern Sie das Gerat gegen unbeabsichtigtes Wiedereinschalten Der Anschluss darf nur von geschultem Fachpersonal vorgenommen werden Achten Sie auf die korrekte Spannungsversorgung GEFAHR Gas im Filter Kondensat und auch verbrauchte Filterelemente konnen giftig oder atzend sein Schalten Sie vor Beginn der Wartungsarbeiten die Gaszufuhr ab und sp len Sie die Gasleitungen ggf mit Luft Bitte sorgen Sie ggf f r eine sichere Ableitung des Gases Sch tzen Sie sich bei der Wartung vor giftigen tzenden Gasen Tragen Sie die entsprechende Schutzausr stung Gasaustritt Der Filter darf beim Ausbau nicht unter Druck stehen Besch digte Teile oder O Ringe nicht wieder verwenden 8 BX410011 12 2011 Art Nr 90 310 46 Bedienungs und Installationsanleitung Installation and Operation Instruction h f Analysenfilter Sample gas filter PU MERA AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 TECHNOLOGIES Vorgehensweise gt AGF T 30 AGF PV S2 Uberwurfmutter abdrehen dabei Glas festhalten gt Alle anderen Bugel ziehen dabei Filterglas festhalten gt Glas bei gleichzeitigem Festhalten des Filterkopfes und leichtem hin und herbewegen vorsichtig nach unten hin abnehmen gt AGF PV 30 AGF PV S2 AGF T 30 RAV PV 30 Fil
16. iten gelten sind diese in der Bedienungsanleitung gesondert beschrieben Bitte beachten Sie beim Anschluss die Kennwerte der Filter und bei Ersatzteilbestellungen die richtigen Ausf hrungen i HINWEIS Die Typen AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 erfullen die grundlegenden Sicherheitsanforderungen der Richtlinie 94 9 EG und sind somit fur den Einsatz im Ex Bereich geeignet Zone 1 Gruppe IIB Gefahrenhinweise in 2 1 dringend beachten Durch diese Analysefilter k nnen je nach verwendetem Filterelement siehe auch Kapitel 3 nichtbrennbare Gase und brennbare Gase der Gruppe IIB oder IIC die im Normalbetrieb gelegentlich explosiv sein k nnen Zone 1 geleitet werden Das Typenschild der Filter tr gt jedoch keine Z ndschutzkennzeichnung da die Betriebsmittel nicht in den Anwendungsbereich der Richtlinie 94 9 EG fallen GEFAHR Der Analysefilter Typ ADF PV 30 ist nicht fur den Einsatz im explosionsgefahrdeten Bereich geeignet 2 Hinweise Bitte uberprufen Sie vor Einbau des Gerates ob die genannten technischen Daten den Anwendungs parametern entsprechen Uberprufen Sie ebenfalls ob alle zum Lieferumfang gehorenden Teile vollstandig vorhanden sind Der Einsatz der Gerate ist nur zulassig wenn das Produkt unter den in der Bedienungs und Installationsanleitung beschriebenen Bedingungen dem Einsatz gem Typenschild und f r Anwendungen fur die es vorgesehen ist verwendet wird die Betriebsmittel i
17. mular kann per E Mail angefordert werden service buehler technologies com 7 1 Entsorgung Bei der Entsorgung sind die gesetzlichen Vorschriften insbesondere f r die Entsorgung von elektronischen Bauteilen zu beachten 8 Beigef gte Dokumente Erkl rung in Anlehnung an die Richtlinie 94 9 EG HX410002 Dekontaminierungserklarung BX410011 12 2011 Art Nr 90 310 46 9 Bedienungs und Installationsanleitung Installation and Operation Instruction Ww Analysenfilter Sample gas filter BUHERI AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 TECHNOLOGIES 1 introduction This manual is suitable for sample gas filters AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 and ADF PV 30 All types can be used for gas filtration in gas analysing systems You can get the probe type from the type plate There is the order number and also a part number and type marking If there are special instructions for a certain type they are described in the manual Regard the specific limits of the filters Please only order the spare parts which matching the probe type The filter types AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 correspond to the essential requirements of the directive 94 9 EC Therefore they can be used in explosive atmosphere zone1 Group IIB note indications of risk in 9 1 Depending on the used filter element See also chapter 10 inflammable gases and flammable gases only temporary explo
18. n eigensicheren Stromkreisen betrieben werden DIN EN 60079 14 und DIN EN 61241 14 beachten das Beschaltungsger t selber au erhalb des explosionsgef hrdeten Bereichs installiert wird berwachungsvorrichtungen Schutzvorrichtung korrekt angeschlossen sind die Service und Reparaturarbeiten von B hler Technologies GmbH durchgef hrt werden soweit sie nicht in dieser Anleitung beschrieben sind Originalersatzteile verwendet werden Das Errichten elektrischer Anlagen in explosionsgef hrdeten Bereichen erfordert in Deutschland die Beachtung folgender Vorschriften EN 60079 14 DIN VDE 0165 T1 Errichten elektrischer Anlagen in explosionsgef hrdeten Bereichen EN 61241 14 DIN VDE 0165 T2 Elektrische Betriebsmittel zur Verwendung in Bereichen mit brennbarem Staub Auswahl Errichtung und Instandhaltung ElexV Verordnung ber elektrische Anlagen in explosionsgef hrdeten R umen Im Ausland sind die entsprechenden Landesvorschriften zu beachten Diese Bedienungsanleitung ist Teil des Betriebsmittels Der Hersteller beh lt sich das Recht vor die Leistungs die Spezifikations oder die Auslegungsdaten ohne Vorank ndigung zu ndern Bewahren Sie die Anleitung f r den sp teren Gebrauch auf BX410011 12 2011 Art Nr 90 310 46 3 Bedienungs und Installationsanleitung Installation and Operation Instruction A Analysenfilter Sample gas filter PU MERA AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 3
19. rden Unfallverh tungsvorschriften der Berufsgenossenschaften beachtet werden in Deutschland Allgemeine Vorschriften VBG 1 und Elektrische Anlagen und Betriebsmittel VBG 4 die zul ssigen Daten und Einsatzbedingungen eingehalten werden Schutzeinrichtungen verwendet werden und vorgeschriebene Wartungsarbeiten durchgef hrt werden bei der Entsorgung die gesetzlichen Regelungen beachtet werden Wartung Reparatur Reparaturen an den Betriebsmitteln d rfen nur von B hler autorisiertem Personal ausgef hrt werden Nur Umbau Wartungs oder Montagearbeiten ausf hren die in dieser Bedienungs und Installationsanleitung beschrieben sind Nur Original Ersatzteile verwenden Bei Durchf hrung von Wartungsarbeiten jeglicher Art m ssen die relevanten Sicherheits und Betriebsbestimmungen beachtet werden 4 BX410011 12 2011 Art Nr 90 310 46 Bedienungs und Installationsanleitung Installation and Operation Instruction h Analysenfilter Sample gas filter PU MERA AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 TECHNOLOGIES GEFAHR a Giftige atzende Gase Messgas kann gesundheitsgef hrdend sein Sorgen Sie ggf f r eine sichere Ableitung des Gases Stellen Sie vor Beginn der Wartungsarbeiten die Gaszufuhr ab und sichern Sie sie gegen unbeabsichtigtes Aufdrehen Sch tzen Sie sich bei der Wartung vor giftigen tzenden Gasen Tragen Sie die entsprechende
20. sive in normal operation zone 1 group IIB or IIC can led through this sample gas filters There is no Ex designation on the type plate of the filters because they are not within the scope of directive 94 9 EC DANGER The filter type ADF PV 30 is not applicable in explosive atmosphere 2 Important advice Please check before installation of the device that the technical data matches the application parameters Also check that the delivery is complete Operation of the device is only valid if the product is used under the conditions described in the installation and operation instruction the equipment is connected intrinsically safe take care of EC directives 94 9 EC EN 60079 14 and EN 61241 14 the controller is mounted outside of potentially explosive atmospheres monitoring devices and safety devices are installed properly service and repair is carried out by Buhler Technologies GmbH unless described in this manual only original spare parts are used EC directives 94 9 EG and according national safety rules for installation of electrical equipment in hazardous areas are obeyed This manual is part of the equipment The manufacturer keeps the right to modify specifications without advanced notice Keep this manual for later use 10 BX410011 12 2011 Art Nr 90 310 46 Bedienungs und Installationsanleitung Installation and Operation Instruction A Analysenfilter Sample gas filter u BURNDERN
21. t AGF T 30 and AGF PV S2 Turn off nut while holding the filter glass gt All others Pull out bracket while holding the filter glass gt While holding the head remove the filter glass to the bottom by swinging the glass a little bit back and forth gt AGF PV 30 AGF PV S2 AGF T 30 RAV PV 30 Remove the filter element and assemble new one gt ADF PV 30 change the adsorbent gt K AGF o Unscrew the supporting tube carrying the filter element o Remove the filter element from the supporting tube and replace it by a new one o Refit the supporting tube to the filter head by hand The filter element is self sealing due to a slight surface pressure Avoid to high surface pressure gt Check seals While holding the head reassemble filter glass by swinging the glass a little bit back and forth Plug in bracket tighten nut Assure proper fixing gt Regard local laws and standards concerning the disposal of used filter elements or adsorbent 16 BX410011 12 2011 Art Nr 90 310 46 Bedienungs und Installationsanleitung Installation and Operation Instruction h Analysenfilter Sample gas filter PU MERA AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 TECHNOLOGIES 7 Repair and disposal If the device shows irregularities call 49 0 2102 498955 or your local agent If the device doesn t work correctly after elimination of failures and turning power on the device must be checked by the manufacturer
22. ten Bereichen bitte zusatzlich beachten Je nach verwendetem Filterelement k nnen auch durch die Analysefilter AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 nichtbrennbare Gase und brennbare Gase die im Normalbetrieb gelegentlich explosiv sein k nnen Zone 1 der Gruppe IIB oder IIC geleitet werden beachten Sie Tabelle 1 Filterelement Typ Geeignet fur Gase der Explosionsgruppe 82 Gruppe IIC Zone 1 _ S2KU Gruppe IIC Zone 1 F2 Gruppe IIB Zone 1 F235 Gruppe IIB Zone 1 4 Transport und Lagerungsvorschriften Die Produkte nur in der Originalverpackung oder einem geeigneten Ersatz transportieren Bei langerer Nichtbenutzung sind die Betriebsmittel gegen Feuchtigkeit und Warme zu schutzen Sie mussen in einem uberdachten trockenen und staubfreien Raum bei einer Temperatur von 20 C bis 60 C aufbewahrt werden 5 Aufbauen und Anschlie en Der Filter soll so eingebaut werden dass ein Filterwechsel noch moglich ist siehe unter 6 Wenn der Filter aus einer Kontur herausragt beachten Sie bitte dass die Gefahr einer Beschadigung besteht Mitte Anschlu ein aus A000020D AGF PV 30 5 1 Gasanschlusse Die Anschl sse sind mittels geeigneter Verschraubungen G 14 oder NPT 1 4 sorgf ltig und fachgerecht anzuschlie en Die Durchflussrichtung ist auf dem Filterkopf mit einem Pfeil gekennzeichnet Der Kopf der Filter kann gedreht werden um die Seite von Ein und A
23. ter PU MERA AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 TECHNOLOGIES 3 Produktbeschreibung Die hier beschriebenen Filter basieren auf den gleichen Gasanschl ssen und dem gleichen Befestigungsbild Die Kennzeichnung xx steht f r das jeweilig eingesetzte Filterelement AGF PV 30 xx Filter mit PVDF Kopf AGF PV S2 Filter mit PVDF Kopf mit berwurfmutter AGF PV 30 xx A dito mit Kondensatablass GL 25 AGF T 30 xx Filter mit PTFE Kopf mit berwurfmutter ADF PV 30 L Zum Befullen mit Adsorptionsmittel Filterkopf aus PVDF RAV PV 30 xx Raumluftfilter mit PVDF Kopf Ersatzfilterelemente hierf r Artikel Nr Packungzu Type Artikel Nr Packungzu 41 01 00 10 5 Stk 41 03 00 50 5 Stk 4101002 25 Stk 41 02 01 30 5 Stk S2 KU 41 01 0140 5 Stk 41 02 00 50 2 Stk 41 01 01 50 25 Stk F25 L 41 01 01 20 2 Stk K AGF PV 30 A Koaleszenzfilter mit PVDF Kopf Ersatzfilterelement hierf r 12 57 C 49 32 001 1 Stk 12 57 C 49 32 002 1 Stk mit PVDF Kappe f r Artikel Nr 4150699 zum Verschrauben f r Artikel Nr 41506995 Die maximale Gastemperatur ist 100 C Der maximale Druck betr gt 4 bar abs 6 BX410011 12 2011 Art Nr 90 310 46 Bedienungs und Installationsanleitung Installation and Operation Instruction _ Analysenfilter Sample gas filter BUHERI AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 TECHNOLOGIES i HINWEIS Bei Einsatz in explosionsgefahrde
24. terelement abziehen und neues aufsetzen gt ADF PV 30 Adsorptionsmittel austauschen gt K AGF o Stutzrohr mit Filterelement vom Filterkopf abschrauben o Filterelement vom Stutzrohr abziehen und neues Element aufschieben o Stutzrohr mit Filterelement handfest in den Filterkopf einschrauben Die Selbstabdichtung erfolgt ber den leichten stirnseitigen Andruck des Filterelements Eine zu starke Flachenpressung ist zu vermeiden gt Nach berpr fen der Dichtung Glas bei gleichzeitigem Festhalten des Filterkopfes und leichtem hin und herbewegen wieder aufsetzen und B gel stecken bzw Uberwurfmutter anziehen Auf sicheren Sitz achten gt Bei der Entsorgung von Filterelementen oder Adsorptionsmittel die gesetzlichen Regelungen beachten 7 Instandsetzung und Entsorgung Sollte ein Fehler beim Betrieb auftreten wenden Sie sich bitte an unseren Service Tel 49 0 2102 498955 oder Ihre zust ndige Vertretung Ist nach Beseitigung eventueller St rungen und nach Einschalten der Netzspannung die korrekte Funktion nicht gegeben muss das Ger t durch den Hersteller berpr ft werden Bitte senden Sie das Ger t zu diesem Zweck in geeigneter Verpackung an B hler Technologies GmbH Reparatur Service Harkortstra e 29 40880 Ratingen Deutschland Bringen Sie zus tzlich die Dekontaminierungserkl rung ausgef llt und unterschrieben an der Verpackung an Ansonsten ist eine Bearbeitung Ihres Reparaturauftrages nicht m glich Das For
25. trap with danger of a flame breakthrough Maximum Surface temperature The maximum surface temperature T ur of the equipment corresponds to the gas temperature Timea Tsurr lt Timea Ignition temperature Obey the ignition temperature of explosive gases as well as the maximum allowed surface temperature according to applicable standards Gas leakage Danger to life and explosion hazard may occur during maintenance or if the device is misused 12 BX410011 12 2011 Art Nr 90 310 46 Bedienungs und Installationsanleitung Installation and Operation Instruction Analysenfilter Sample gas filter AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 vw wE UHER TECHNOLOGIES Risk of breakage Poisoning injury due to emission of toxic or explosive gases Protect the equipment against being hit Protect the device against falling objects 3 Product description The filters described in this instruction have the same gas ports and the same mounting flange The designation xx marks the used filter element AGF PV 30 xx Filter with head made of PVDF AGF PV S2 Filter with head made of PVDF fixed with nut AGF PV 30 xx A same but with condensate drain port GL 25 AGF T 30 xx Filter with head made of PTFE fixed with nut ADF PV 30 L For use with adsorbent Filter head made of PVDF RAV PV 30 xx Ambient air filter with head made of PVDF Spare filter elements 4101002 F25 41 02 01 30 5 p
26. usgang bei RAV nur Eingang zu tauschen Achten Sie darauf ob Sie eine Version mit G Gewinden oder die mit NPT Gewinden haben Letztere hat an die Artikelnummer auf dem Typenschild ein I angeh ngt BX410011 12 2011 Art Nr 90 310 46 T Bedienungs und Installationsanleitung Installation and Operation Instruction A Analysenfilter Sample gas filter PU MERA AGF PV 30 AGF PV S2 AGF T 30 K AGF PV 30 RAF PV 30 ADF PV 30 TECHNOLOGIES 5 2 Anschluss eines Bypasses oder Feuchtefuhlers Nicht bei AGF T 30 nicht sinnvoll bei RAV PV 30 Zu diesem Zweck ist auf dem Filterkopf ein weiteres G 14 Innengewinde vorgesehen welches ab Werk mit einem Stopfen versehen ist Um dieses zu Nutzen drehen Sie den Stopfen heraus und schrauben Sie die Verschraubung oder den Feuchtef hler Typ FF hinein Achten Sie auf Dichtheit 6 Wechsel des Filterelementes Das Ger t darf nur von Fachpersonal installiert und gewartet werden das mit den Sicherheitsanforderungen und den Risiken vertraut ist Das Ger t darf nicht au erhalb seiner Spezifikationen betrieben werden Reparaturen an den Betriebsmitteln d rfen nur von B hler autorisiertem Personal ausgef hrt werden F hren Sie nur Umbau Wartungs oder Montagearbeiten aus die in dieser Bedienungs und Installationsanleitung beschrieben sind Verwenden Sie nur Original Ersatzteile Beachten Sie bei der Durchf hrung von Wartungsarbeiten jeglicher Art die relevanten S