1. 30 DMU 6100 FRONT PANEL 1 Main switch ON LED 8 PLAY green REC red LED 4 7 LEDs SIGNAL PEAK of the 6 inputs IN TELECONF IN and the MAIN OUT output PLAY REC selection key PLAY the SYSTEM QO audio output for recording is disabled REC the PLAY audio input is disabled SET key to enter the configuration menu and select the relevant parameters press and hold for 3 seconds to enter 7 Backlit LCD IN VOLUME key to enter the audio input volume menu and select the relevant parameters 9 OUT VOLUME key to enter the audio output volume menu and select the relevant parameters MODE key to enter the operating mode menu and select the relevant parameters 7 Keys Y when the LCD displays the default page indicating the operating mode these keys allow to adjust the internal loudspeaker volume see point 14 After entering a menu by means of the SET MODE IN VOLUME and OUT VOLUME keys these keys change the value of the selected parameter 2 Press the ENTER key to confirm and save new settings Without pressing it note after some time the selected menu will automatically quit changes are not saved in the SET and MODE menus e changes are anyway saved in the IN VOLUME and OUT VOLUME menus After entering the configuration menu SET the ENTER key also resets the entire system and stops the discussion in progress When necessary the system reset can be forced by pressing an
2. FUNZIONAMENTO DELLA CONSOLE SE IMPOSTATA COME DELEGATO II delegato soggetto all eventuale limitazione da 1 a 6 configurabile nel software dell unit cen trale DMU 6100 parametro MIC MODE SET UP del menu MODE del numero massimo di microfoni aperti contemporaneamente Se tale limite gi stato raggiunto non pi possibile l attivazione di un altra console delegato Se il parametro MIC MODE SET UP stato impostato su 1 MIC ACT O RIDE un solo microfono attivo con override del successivo si ha una sola console dele gato attiva alla volta che automaticamente disattivata non appena se ne inserisce un altra Non possibile attivare il microfono se e un presidente ha effettuato il RESET un presidente si inserito con la PRIORITA e l unit centrale non ha rilevato la console e tutte le console delegato sono disabilitate tramite il parametro MIC MODE SET UP dell unit centrale e Tasto grande A attiva il microfono della console si accendono il LED rosso e l anello luminoso del microfono L attivazione del microfono momentanea quando il tasto mantenuto premuto oppu re stabile se il tasto pigiato una sola volta per un istante Se rilasciato o premuto di nuovo per un istante in caso d inserzione stabile si disattiva il microfono il LED rosso e l anello luminoso del microfono si spengono Se si tenta l attivazione del microfono quando il numero massimo di microfoni aperti gi stato rag
3. THD lt 0 1 Max nominal min gain LINE MIC PHANTOM INPUT LEVEL MAIN OUT 0 dBu THD lt 0 1 Max nominal min gain S N ratio PLAY INPUT dual RCA Input level 1 input connected only MAIN OUT 0 dBu THD lt 0 1 Impedance 1 kHz Frequency response 3 dB S N ratio TELECONF IN FROM INPUT mono RCA Input level MAIN OUT 0 dBu THD lt 0 1 Impedance 1 kHz Frequency response 3 dB S N ratio INSERT IN MIC UNIT SPKR mono RCA Input level Impedance 1 kHz Frequency response 3 dB S N ratio MAIN OUT balanced XLR 3M Output level Presence control 0 0 A and B OUTPUTS 2 x mono RCA Output level Frequency response 3 dB Output impedance 1 kHz S N ratio Routed input audio signals TELECONF OUT TO OUTPUT mono RCA Output level Frequency response 3 dB Output impedance 1 kHz S N ratio Routed input audio signals 100 240 V ac 50 60 Hz 1 7 A 230 V 3 5 A 115 V 400 W 250 V IEC 5x20 type FAA 1 pc F1A 1 pc 0 50 C 32 122 F 430 mm 88 mm 310 mm 5 65 kg 40 dB 50 Hz 20 kHz to MAIN OUT 20 kO bal 9 kO unbal 23 V I max 23 mA 12 dB oct 3dB cut 100 Hz 14 dBu line input nominal gain 54 dBu 48 dBu 14 dBu saturation gt 0 dBu THD 0 5 gt 65 dBA 27 dBu 4 dBu 13 dBu saturation gt 20 dBu THD 0 5 gt 85 dBA nominal 7 dBu max 12 dBu THD 0 5 9 kQ
4. Due ingressi ausiliari A e B con prese XLR ognuno dei quali configurabili tramite microinterruttori PHANTOM MIC LINE HIGH PASS e con controllo di guadagno e comando di abilitazione mute e Ingresso audio PLAY ed uscita audio SYSTEM per la registrazione Ingresso ed uscita audio per teleconferenza e Sistema di traduzione simultanea o sequenziale una lingua tradotta e Ogni console pu essere configurabile come presidente massimo 3 delegato interprete Massimo 2 presidenti non hanno alcuna limitazione per l abilitazione a parlare ed inoltre possono tacitare temporaneamente o disabilitare le console attive dei delegati e le eventuali prenotazioni Nel caso vi siano due interpreti uno solo alla volta pu attivare il microfono una sola lingua tradotta e Display LCD retroilluminato sull unit centrale DMU 6100 e tasti funzione per impostare il sistema la modalit di funzionamento numero max di delegati abilitati o prenotati per parlare ecc la configurazione priorit tra ingressi A B ed il sistema funzione VOX ingressi A B ecc volumi PANNELLO FRONTALE DMU 6100 Interruttore generale LED ON apparecchio acceso LED di segnalazione dello stato PLAY verde REC rosso 7 LED di segnalazione SIGNAL PEAK segnale picco dei 6 ingressi IN A IN B MIC UNITS INTERPR MIC PLAY IN TELECONF IN e dell uscita MAIN OUT Tasto per la commutazione dello s
5. LED ROSSO LAMPEGGIANTE la console interprete stata attivata ma il microfono momentanea mente e volutamente spento MUTE per la pressione mantenuta sul tasto grande A LED GIALLO LAMPEGGIANTE l interprete ha richiesto di parlare lentamente SPEAK SLOWLY in modalit di traduzione simultanea II LED e l anello luminoso lampeggiano la comunicazione con l unit centrale interrotta da pi di 30 secondi In tale evenienza il microfono rimarr comunque abilitato fino alla disattivazione da parte dell interprete e non sar possibile reinserirlo fino a quando non si sar ripristinata la comuni cazione con l unit centrale I LED e l anello luminoso si spengono senza che si sia premuto un tasto si inserito l altro inter prete TEST DELLE CONSOLE ALL ACCENSIONE DEL SISTEMA Durante l accensione del sistema oppure dopo la sua reinizializzazione tramite il tasto ENTER nel menu SET dell unit centrale DMU 6100 gli anelli luminosi di tutte le console si accendono in sequenza partendo da quelle pi vicine all unit centrale La non accensione di uno o pi anelli luminosi indica un problema nella linea nel tratto immediatamente successivo all ultima console 23 Li con l anello luminoso acceso Nelle console per delegati ed interpreti gli anelli luminosi rimangono accesi per 2 secondi mentre in quelle per presidenti rimangono accesi per 4 secondi questi tempi possono essere decuplicati 20 secondi per i delegati
6. REC PLAY 11 2 TELECONF Tensione d alimentazione Corrente assorbita max Consumo max Fusibile alimentazione Altri fusibili interni Temperatura di esercizio Dimensioni I h p Peso netto Ingressi MIC LINE INPUT A B XLR 3F bilanciato Escursione del controllo di guadagno Risposta in frequenza 3 dB Impedenza 1 kHz Alimentazione Phantom Filtro passa alto Soglia d intervento del VOX Livello MIC MAIN OUT 0 dBu THD 0 196 Guadagno max nominale min Rapporto segnale Livello LINE MIC PHANTOM MAIN OUT 0 dBu THD lt 0 1 Guadagno max nominale min Rapporto segnale rumore Ingresso PLAY doppio RCA Livello d ingresso 1 solo ingr collegato MAIN OUT 0 dBu THD lt 0 1 Impedenza 1 kHz Risposta in frequenza 3 dB Rapporto segnale rumore Ingresso TELECONF IN FROM mono RCA Livello d ingresso MAIN OUT 0 dBu THD lt 0 1 Impedenza 1 kHz Risposta in frequenza 3 dB Rapporto segnale rumore Ingresso INSERT IN UNIT SPKR RCA Livello d ingresso Impedenza 1 kHz Risposta in frequenza 3 dB Rapporto segnale rumore Uscita MAIN OUT XLR 3M bilanciato Livello d uscita Controllo Presence control Uscite 0 OAeB 2x RCA Livello d uscita Risposta in frequenza 3 dB Impedenza d uscita 1 kHz Rapporto segnale rumore Ingressi audio inviati alle uscite
7. Uscita 0 0 SYSTEM doppio RCA Livello d uscita Risposta in frequenza 3 dB Impedenza d uscita 1 kHz Rapporto segnale rumore Ingressi audio inviati all uscita Uscite 0 0 LINE 1 e LINE2 2 x mono RCA Livello d uscita Risposta in frequenza 3 dB Impedenza d uscita 1 kHz Rapporto segnale rumore Ingressi audio inviati alle uscite Uscita INSERT OUT MIC UNIT SPKR Livello d uscita Risposta in frequenza 3 dB Impedenza d uscita 1 kHz Rapporto segnale rumore Ingressi audio inviati all uscita Amplificatore MONITOR interno Potenza Uscita cuffie jack 6 3 mm pannello front Risposta in frequenza 3 dB Rapporto segnale rumore Ingressi audio monitorati Connettori EURO a 2 poli ingressi uscite Ingressi MIC LINE INPUT A CMD IN MIC LINE INPUT B CMD IN CHIME COMMAND Attivazione Tensione max corrente max Ingresso controllo di volume remoto REMOTE VOLUME CONTROL Potenziometro da utilizzare Tensione max corrente max Uscita SPEAK SLOWLY contatto pulito n a Tensione max corrente max Connettori RJ LINE 1 LINE 2 INPREPRETER I INTERPRETER II Tensione max corrente max Microfono Risposta in frequenza 3 dB Rapporto segnale rumore Limiter interno MIC AUT0 0FF soglia d intervento Tensione corrente Potenza amplificatore interno Dimensioni solo la base I h p Peso Lunghezza flessibile con mic Cavo per la connessione incluso U
8. if pressed once for an instant the microphone gets open the red LED and the light ring get lit if pressed again for an instant the microphone the red LED and the light ring turn off After the microphone activation if this button is pressed again and hold the microphone will momentary get muted MUTE and the red LED will be flashing after releasing the microphone and the red LED will turn on again It is always possible to mute the microphone by pressing and holding this button while another quick press and the immediate release turns the console off During the simultaneous translation if a chairman gets the PRIORITY nothing will happen because only the translated language the interpreter s audio signal is sent to all consoles During the sequential translation the interpreter has a higher priority than chairmen and delegates which are momentary muted flashing yellow LED when the interpreter console is on e B short button SPEAK SLOWLY if pressed once during the simultaneous translation it sends a signal flashing yellow LED to all activated consoles delegates chairmen and the interpreter itself as well as request to SPEAK SLOWLY the SPEAK SLOWLY output turns on too see the DMU 6100 central unit rear panel point 34 Another B button press cancels the SPEAK SLOWLY signal which can be also disabled by turning the console off A button press Note this button does not work during the sequential translat
9. 50 Hz 20 kHz to MAIN OUT gt 85 dBA nominal 7 dBu max 12 dBu THD 0 5 8 kQ 135 Hz 20 kHz to MAIN OUT gt 85 dBA nominal 4 dBu max console headphones outputs 1 V on 150 THD 0 5 max 11 dBu limiter action THD lt 1 on console headphones outputs 20 kQ 170 Hz 16 kHz to console headphones outputs gt 80 dBA nominal 0 dBu THD lt 0 1 max 20 dBu THD 0 5 max 15 dB 2 1 kHz nominal 7 dBu THD lt 0 1 max 10 dBu THD 0 5 25 Hz 20 kHz 1000 gt 90 dBA MIC LINE A A out MIC LINE B B out nominal 7 dBu THD lt 0 1 max 10 dBu THD 0 5 45 Hz 20 kHz 1000 gt 85 dBA MIC LINE A MIC LINE B PLAY CONSOLES 0 0 SYSTEM OUTPUT dual RCA Output level Frequency response 3 dB Output impedance 1 kHz S N ratio Routed input audio signals 0 0 LINE 1 and LINE 2 OUTPUTS 2 x mono RCA Output level Frequency response 3 dB Output impedance 1 kHz S N ratio Routed input audio signals INSERT OUT MIC UNIT SPKR mono RCA Output level Frequency response 3 dB Output impedance 1 kHz S N ratio Routed input audio signals MONITOR AMPLIFIER internal Power Headphones 6 3 mm jack on front panel Frequency response 3 dB S N ratio Routed input audio signals 2 POLE 1 0 EURO CONNECTORS INPUTS MIC LINE INPUT A CMD IN MIC LINE INPUT B CMD IN CHIME COMMAND Activation Max voltage max current INPUT RE
10. NEXT geht das gr ne LED an durch erneutes Dr cken der Taste wird die Voranmel dung gel scht gr nes LED geht aus Der rot blinkende LED f r 3 Sekunden geht auch an wenn die maximale Anzahl Voranmeldungen erreicht ist Ist das Mikrofon schon f r l ngere Zeit an durch ein kurzes Dr cken der Taste A besteht die M glichkeit durch erneutes Gedr ckthalten zu einer vor bergehenden Aktivierung berzugehen B short button MUTE it momentary mutes the microphone if this has been previously opened by using the A long button in toggle mode and the red LED starts flashing Another press cancels the MUTE state the microphone is open and the red LED is lit without flashing again W hrend der MUTE Funktion wird die Abgeordnetensprechstelle mitgerechnet in der Gesamtsum me aller aktiven Mikrofone nur von Bedeutung falls die maximale Anzahl gleichzeitig aktiver Mikro fone erreicht sein sollte Das Mikrofon der Abgeordnetensprechstelle kann durch Dr cken der groBen Taste A deaktiviert werden auch wenn das Mikrofon auf MUTE eingestellt wurde Bei Eingabe des Vorsitzenden auf VORRANG wird das aktive Mikrofon der Abgeordneten vor ber gehend deaktiviert und das rote LED leuchtet auf MUTE von Seiten des Vorsitzenden Am Ende des VORRANGs wird das Mikrofon wieder eingeschaltet und das rote LED geht erneut an Bei Aktivierung der Funktion RESET durch einen Vorsitzenden wird das angeschaltete Abgeordne tenmikrofon ausge
11. OFF OFF gt gt VORRANG gt 0 0 gt RESET gt or gt OFF OFF gt gt NORMAL gt Q gt VORRANG gt 0 0 gt RESET or Q gt OFF ZUSAMMENFASSUNG DER LED ZEICHEN ROTES LED Das Mikrofon des Vorsitzenden ist aktiviert der Leuchtring ist angeschaltet in der Funktion NORMAL GR NES LED NUR 3 SEKUNDEN BLINKEND Der Vorsitzende hat das RESET aktiviert GR NES LED Der Vorsitzende hat VORRANG eingegeben oder RESET falls der selbe LED 3 Sekunden vorher geblinkt hat GELB BLINKENDES LED Der Dolmetscher bittet darum langsam zu sprechen SPEAK SLOWLY in der Ausf hrung der Simultan bersetzung oder der Sequenz bersetzung und das Mikrofon der Vorsitzendensprechstelle ist f r kurze Zeit deaktiviert Das LED und der Leuchtring blinken auf Die Kommunikation mit der Zentrale wird f r l nger als 30 Sekunden unterbrochen In diesem Fall bleibt das Mikrofon betriebsbereit bis der Vorsitzende es abschaltet und es ist nicht m glich es wieder einzuschalten bis die Kommunikation mit der Zentrale wiederhergestellt ist 68 SPRECHSTELLENFUNKTION BEI EINSTELLUNG ZUM ABGEORDNETEN Der Abgeordnete unterliegt einer eventuellen Eingrenzung von 1 bis 6 konfigurierbar im Software der zentralen Einheit DMU 6100 Parameter MIC MODE SET UP des Men s MODE was die maxi mal gleichzeitig angeschalteten Mikrofone anbelangt Wenn diese Grenze schon erreicht ist ist die Aktivierung einer weiteren Abgeordnetensprechstelle
12. Prenotazione consentita ad un solo delegato dopo aver raggiunto il numero massimo di delegati attivi Quando un delegato disattiva il proprio microfono la console pre notata abilitata automaticamente preimpostato Disattivazione della funzione di prenota zione dei delegati Tramite il tasto SET si accede al men della configurazi one premendolo per un istante sul display LCD appare il testo seguente Per accedere al meni inizialmente necessario mantenere premuto il tasto SET per almeno 3 secondi Successivamente premere il tasto SET ripetutamente per visualizzare i seguenti parametri in rotazione NTERPRETATION e A amp B INPUT MODE e VOX CMD INPUT A e VOX CMD INPUT B e CHIME ON CHAIRM e CONSOLE OUT JACK Usare i tasti e V per selezionare modificare Dopo aver modificato i parametri premere ENTER per confermare ed uscire dal men Dopo aver premuto ENTER per confermare le nuove impostazioni viene reinizializzato il sistema ed interrotta la discussione INTERPRETATION Impostazione della modalit di traduzione sequenziale simultanea disattivata Traduzione sequenziale attivata quando una delle due console interprete chiede l abilitazione disabilitando automaticamente l altra la lingua tradotta l interprete inviata alle 3 uscite audio del sistema linee console MAIN OUT e l uscita per teleconferen za Quando l interprete disattiva il proprio microfono sulle 3 usci t
13. green LED During the simultaneous translation it indicates the interpreter request SPEAK SLOWLY During the sequential translation it indicates the interpreter console activation therefore the delegate microphone is momentary muted The flashing yellow LED can appear on delegate consoles with either open or muted microphones MUTE while it does not appear on consoles that are disabled or booked green LED lit MIC AUTO OFF FUNCTION DELEGATES ONLY If the MIC AUTO OFF function is enabled in the central unit software after 30 seconds with open microphone of continuous no voice detection the relevant console will be automatically turned off Every time that a delegate restart speaking during the last 5 available seconds a 10 second extra time will be granted before turning its microphone off When a delegate microphone is momentary muted MUTE by either a chairman or the delegate interpreter console during the sequential translation the MIC AUTO OFF function is suspended LED CODES FLASHING RED FOR 3 SECONDS ONLY failed try to activate the console its light ring does not get lit The microphone is still off and even the booking request is not accepted because the max number of open microphones has already been reached and the booking is not available too or a chairman has got the PRIORITY or used the RESET command GREEN failed try to activate the console its light ring does not get lit because it has alre
14. occorre quindi rimuovere la causa del primo errore per ottenere la visualiz zazione di quello successivo se presente dopo aver riavviato il sistema Questo messaggio potrebbe apparire dopo l accensione del sistema e la visualizzazione del numero di console in caso di problemi durante la lettura dell EEPROM me moria interna in questo caso sono sempre reimpostati i parametri iniziali ed necessaria l assistenza tecnica non appena possibile Guasti alimentazione e fusibili 6 necessaria l assistenza tecnica Guasto alimentazione interna 12 V d 5 Guasto alimentazione interna 24 V Guasto alimentazione esterna 24 V DPS 6202 Guasto fusibile linee console 1 e 2 Guasto fusibile linee console 3 e 4 DEC 6104 Guasto fusibile linee console 5 e 6 DEC 6104 CONSOLE MICROFONICA DMS 6410 PANNELLO SUPERIORE Microfono con anello luminoso Altoparlante interno LED bicolore visualizzante i colori rosso ver de giallo rosso piu verde a seconda del l impostazione della console presidente de legato interprete Tasti piccolo e grande con funzionalit dipen denti dall impostazione della console presi dente delegato interprete 6 Tasti per la regolazione del volume dell alto parlante interno PANNELLI LATERALI Sono presenti due prese jack 3 5 mm 1 8 una a sinistra una a destra per cuffie registratore PANNELLO POSTERIORE IN Connettore RJ a 10 poli per l i
15. ternen Lautsprechers SEITLICHE PANEELE Es gibt zwei Jack Stecker 3 5 mm 1 8 einer links und einer rechts f r die Kopfh rer Aufnahmeger t HINTERES PANEEL 7 Anschluss RJ zu 10 Polen f r den Eingang des Spezialkabels zu 10 Polen der von der vorherigen Sprechstelle oder der zentralen Einheit DMU 6100 stammt OUT Anschluss RJ zu 10 Polen f r den Aus gang des Spezialkabels zu 10 Polen direkt To The Next From System Microphone Set Central Unit o Line termination zur folgenden Sprechstelle on lst mie unit Mikroschalter f r die Sprechstellenkonfigu rierung als Vorsitzender Abgeordneter oder Dolmetscher 2 Knopf zum Abschluss der zu aktivierenden Delegate Chairman Interpreter Leitung der letzten Sprechstelle console consoles T bongol 64 BESCHREIBUNG DER MIKRONFONSPRECHSTELLE DMS 6410 Jede Mikrofonsprechstelle kann auf einem der 3 m glichen Betriebsmodi eingestellt werden Vorsitzender e Abgeordneter Dolmetscher Ein Basissystem ohne Expansionskarte DEC 6104 kann beinhalten 8 2 Leitungen bestehend aus 30 Sprechstellen DMS 6410 Abgeordneter oder Vorsitzender pro Leitung insgesamt 60 b 2 Dolmetschsprechstellen DMS 6410 verbunden an die daf r vorgesehenen Stecker C H chstens 3 Sprechstellen von Vorsitzenden im ganzen System verbreitet oder nicht verbreitet auf 2 Leitungen Z B k nnen in einem System 57 Abg
16. 200 Hz 12 kHz gt 60 dBA up to 32dB over 100 level 20 dB 48 V dc nominal lt 20 mA max 50 mA internal Ispk max volume 1 W THD lt 1 200 mm 135 mm 60 mm 1 09 kg 450 mm 10 pole special cable with RJ connectors 2 5 m long 60 mW on 16 O 0 596 THD nominal 4 dBu 0 296 THD max 4 5 dBu 170 Hz 16 kHz Wichtig Bevor sie dieses Produkt einschalten und benutzen lesen Sie die in diesem Leitfaden enthaltenen Anweisungen aufmerksam durch Der Leitfaden ist f r k nftige Informationen aufzubewahren Der vorliegende Leitfaden stellt einen Bestandteil des Produkts dar und muss bei einem Eigent merwechsel ebenfalls bertragen werden damit der neue Figent mer die Einstellungs Verwendungs und Sicherheitswarnhinweise kennenlernt Die falsche Anwendung und Einstellung des Produkts befreien RCF S p A von jeglicher Verantwortung Achtung Um Stromst e oder Feuer zu vermeiden darf dieses Produkt nie Feuchtigkeit oder Regen ausgesetzt werden 1 Sicherheitshinweise Alle Hinweise vor allem jene die die Sicherheit betreffen m ssen mit besonderer Sorgfalt gelesen werden denn sie k nnen wichtige Informationen enthalten 2 1 Direkte Stromversorgung aus dem Netz a Die Elektrizit tsspannung des Ger ts kann einen so hohen Wert Grad annehmen dass es Menschen einen Stromschlag versetzt SchlieBen Sie demnach das Ger t nie bei eingeschalteter Netzversorgung an D Bevor Sie dieses Ger t mit Energie
17. 6410 MICROPHONE CONSOLE SET TO DELEGATE 1 page 45 DMS 6410 MICROPHONE CONSOLE SET TO INTERPRETER _ C page 47 CONSOLE CHECK ON REBOOT page 47 DMS 6410 MICROPHONE CONSOLE SET TO BY PASS page 48 SPECIAL 10 POLE CABLE FOR DMS 6410 CONSOLES 1 3 page 48 XLR CONNECTORS BALANCED SIGNAL 1 page49 CONNECTION INDICATIVE EXAMPLE 1 79 SPECIFICATIONS 1 1 1 DOE 50 INDEX DEUTSCH Anmerkungen zur Sicherheit J C AB 1 1 page52 Beschreibungen und Haupteigenschaften ___ 1 1 page 54 Vorderes Paneel DMU 6100 1 page 55 Hinteres Paneel DMU 6100 page 56 Men DMU 65100 58 Fehlermeldungen n page 63 Mikrofonsprechstelle DMS 6410 1 11 page 64 Beschreibung der Mikrofonsprechstelle DMS 6410 1111 page 65 Funktion der Sprechstelle DMS 6410Wenn eingestellt als Pr sident page 67 Funktion der Sprechstelle wenn als Abgeordneter eingestelt________ page 69 Funktion der Sprechstelle wenn als Dolmetscher eingestellt 1 13 page 71 Sprechstellentest bei Anschalten des Systems 1 1 page71 Nicht betriebsbereite Sprechstelle in by pass ___ 72 Spezielles Kabel zu 10 Polen f r Sprechstellen _ page 72 Ausgewogenes Audiokabel mit Steckern XLR 1 1 1 page73 Beispiel f r Anschl sse n 73 Technische Daten 1 1 page7 74 IMPORTANTE P
18. Auf den Jacksteckern jeder Sprechstel le ist das gleiche R ckkehrzeichen f r den Lautsprecher vorhanden Wenn die Kopfh rer benutzt werden ist der Lautsprecher deaktiviert Auf den Jacksteckern einer jeden Sprechstelle befindet sich das Zeichen f r einen eventuellen Anschluss eines Aufnahmeger ts der Lautsprecher ist nicht deaktiviert Auf den Jacksteckern einer jeden Sprechstelle gibt es kein Signal der Lautsprecher ist nicht deaktiviert IMPORTANT Wenn die Simultan bersetzung vorgesehen ist behalten Sie das Parameter CONSOLE OUT JACK auf HEADPHONES andernfalls wird es nicht m glich sein die bersetzte Sprache zu h ren ber Kopfh rer i Bei den Sprechstellen f r Dolmetscher sind die Jackstecker immer in der Ausf hrung HEADPHO NES Nutzung f r Kopfh rer eingestellt abgesehen von der Parametereinstellung CONSOLE OUT JACK Durch Dr cken der Taste IN LAUTST RKE gelangt man ins Einstellungsmen der Eingangslautst r ken Durch wiederholtes Dr cken erh lt man die folgenden Parameter in Rotation Verwenden Sie die Tasten A und W um eine nderung herbeizuf hren maximales Niveau 16 voreingestelltes Niveau 10 Niveau 0 MUTE Lautst rke der Vorsitzenden und der Abgeordnetensprechstelle Lautst rke der Dolmetschersprechstellen Lautst rke des Eingangs MIC LINE INPUT A mit Stecker XLR Lautst rke des Eingangs MIC LINE INPUT B mit Stecker XLR Lautst rke des Eingang
19. Funktion Eingange A B etc die Lautst rken 54 Vorderes Paneel DMU 6100 Hauptschalter LED ON angeschaltetes Ger t 3 Signal LED des PLAY gr n REC rot Zustandes 7 x Signal LED SIGNAL PEAK der 6 Eingange IN A IN B MIC UNITS INTERPR MIC PLAY IN TELECONF IN und des Ausgangs MAIN OUT 8 Umschalter PLAY REC Im Zustand PLAY ist der Audioausgang f r die Aufnahme SYSTEM nicht aktiv im Zustand REC ist der Audioeingang PLAY nicht aktiv 6 Taste SET f r die Auswahl der Parameter im Konfigurierungsmen Durch 3 Sekunden Dr cken der Taste SET gelangt man dorthin 7 Hintergrundbeleuchtetes LC Display Taste IN LAUTST RKE f r die Lautst rkeneinstellung der Eing nge Taste OUT LAUTSTARKE f r die Lautst rkeneinstellung der Ausg nge Taste MODE f r den Zugang und die Parameterauswahl im Einstellungsmen 7 Tasten und V Im Anfangsmen der Defaults der die Ausf hrung visualisiert erlaubt die ser die Lautst rke des internen Lautsprechermonitors zu erh hen oder zu vermindern siehe Punkt 14 wenn hingegen ein Men durch die Tasten SET MODE IN LAUTSTARKE und OUT LAUTSTARKE ausgesucht wird wird hiermit der jeweilige Parameter eingestellt 2 Die Taste ENTER dr cken um die Einstellungen zu best tigen oder zu speichern Wenn ENTER nicht gedr ckt wird und man auf den anfangs Defaultbildschirm wartet ist der Effekt je nach ausgew hltem Men unterschiedlich Kei
20. Leitungen ist gegens tzlich vorausgesetzt dass es h chstens 30 pro Leitung gibt ANSCHLUSS DOLMETSCHERSPRECHSTELLE Die zwei Dolmetschersprechstellen falls genutzt werden an 2 Steckern die der Zentrale DMU 6100 gewidmet sind angeschlossen 65 HO S 1 13Ga Wichtig E ENDUNG DER LEITUNGEN F r eine ordnungsgem e Endung der Leitungen geht man wie folgt vor Auf der letzten Sprechstelle Abgeordneter oder Vorsitzender einer Leitung ist es n tig ON den zugeh rigen Schalter LINE TERMINATION der sich hinten befindet zu dr cken Auf den restli chen Sprechstellen einer jeden Leitung muss der Schalter auf OFF geschaltet sein erhoben F r den Fall dass eine der Sprechstellen w hrend der Strecke die Schaltung LINE TERMINA TION falschlicherweise auf ON wahrend der Konfiguration gedr ckt hat werden alle vorherigen Sprechstellen wieder erkannt Anschaltung des Leuchtringes w hrend hingegen die folgenden Sprechstellen von der zentralen Einheit DMU 6100 nicht wahrgenommen werden Wenn zumindest eine Dolmetschsprechstelle verwendet wird muss man sich auf der zentralen Einheit DMU 6100 versichern dass sich der zugeh rige Mikroschalter der Endung auf OFF befindet Dolmetscher anwesend Auf der Dolmetschsprechstelle ist es hingegen irrelevant ob man den zugeh rigen Schalter LINE TERMINATION dr ckt Wenn eine Dolmetschsprechstelle nicht benutzt wird muss man die jeweilige nicht genutzte Lei
21. Lieferumfang Haupteigenschaften e Standardkonfiguration bis zu 60 Sprechstellen verteilt auf die beiden Linien Konfiguration mit Erweiterungskarte bis zu 180 Sprechstellen verteilt auf sechs Linien Die zus tzlichen 120 Sprechstellen zur Standardkonfiguration k nnen an der Zentrale durch Installation der optionalen Karte DEC 6104 und durch Hinzuf gen eines externen Netzteiles DPS 6202 verbunden werden Zwei AUX Eing nge A und B XLR beide sind durch Mikroschalter konfigurierbar PHANTOM MIC LINE HIGH PASS und mit einer Lautst rkeregelung und einer Mute Funktion ausgestattet Eingang Audio PLAY und Ausgang Audio SYSTEM f r die Aufnahme e Ein und Audioausgang f r eine Telekonferenz Simultanes oder sequentielles bersetzungssystem f r eine bersetzte Sprache Jede Sprechstelle ist als Pr sident maximal 3 Abgeordneter Dolmetscher maximal 2 konfigurierbar De Pr sident hat eine Priorit tsfunktion und kann alle aktiven Sprechstellen deaktivieren und evtl Anmeldelisten l schen Wenn 2 Dolmetschersprechstellen vorhanden sind kann aber nur eine Sprechstelle jeweils aktiviert werden nur ein Dolmetscherkanal Hintergrundbeleuchtetes LC Display auf der Zentrale DMU 6100 und Funktionstasten um das System einzustellen Die Funktionsart und weise max Anzahl an Delegierten oder zum Sprechen vorangemeldete Personen etc Die Konfiguration Vorrang zwischen dem Eingang A B und dem System VOX
22. OUT und dem Ausgang f r Telekonferenz wird ein gemischtes Signal der Sprechstelle zugesendet IN A IN B IN PLAY und die Glocke Chime IMPORTANT Durch Auswahl der Simultan bersetzungsmodalit t ist es unheimlich wichtig ein Verst rkungsaudiosystem zu verkn pfen an den Ausgang LINE LEBEL MAIN OUT der zentralen Einheit DMU 6100 um die Originalsprache h ren zu k nnen voreingestellt Deaktivierte bersetzung den 3 Ausg ngen 60 des Systems Sprechstellenleitung MAIN OUT und Telekonferenz wird das gemischte Signal der Sprechstelle verschickt IN A IN B IN PLAY und die Glocke Chime A amp B INPUT MODE Einstellung Vorrangigkeit der Audioeing nge MIC LINE INPUT A und B voreingestellt Die Eingange A B und das Signal der Sprechstellen sind vermischt Die Eing nge A und B sind untereinander blockiert der erste aktive Eingang schlieBt den andern aus ihr Signal ist mit dem der Sprechstelle vermischt Eingang A ist wichtiger als Eingang B Ihr Signal ist mit dem der Mikrofone der Sprechstellen vermischt Die Eing nge A und B sind vermischt und ihr Signal ist wichtiger als das der Sprechstellen Das Signal der Sprechstellen ist wichtiger als das gemi schte aus den Eing ngen A und B Das Signal der Sprechstellen ist wichtiger als das vermischte Signal zusammengesetzt aus Eingang B und den Sprechstellen HUSLNAC VOX CMD INPUT A vox Einstellung und Eingangsbefehl Audio MI
23. Signale der zwei Sprech stellenlinien unabh ngig bertragen jede Linie hat maximal 30 Sprechstellen PRESENCE CONTROL Klangkontrolle Presence des MAIN OUT Ausgangs FLAT Linear nicht ver ndertes Signal EQ aktivierte Klangkontrolle 80 Hauptaudioausgang LINE LEVEL MAIN OUT mit XLR Buchse 31 CHIME LEVEL Kontrolle der Gonglautst rke Chime 3 61 74 FUSE T REMOTE VOLUME CHIME SPEAK LINET INTERPR I LINE2 INTERPR II conma ci s M B e Fe Ze E es SC EN WADE 0 5 5 09 62 REMOTE LAUTSTARKE CONTROL Anschluss f r die Fernsteuerung der Lautst rke nicht im Lieferumfang ein 22k Potentiometer des Typ B wird empfohlen des Ausgangs MAIN OUT 63 CHIME COMMAND Anschluss f r den externen Aktivierungsbefehl potential freier SchlieBkon takt des Gongs chime Anmerkung Der Gong kann auch durch die Einstellung ACTIVE des Parameters CHIME ON CHAI RM im Konfigurationsmen SET durch die Prioritatsfunktion der Pr sidentensprechstelle akti viert werden 69 SPEAK SLOWLY Ausgang SPEAK SLOWLY Sprechen Sie langsam potential freier Kontakt max 28 V DC 1 A Der Aufruf SPEAK SLOWLY wird durch eine gelb blinkende LED an den Sprechstellen signalisiert wenn der SITE Befehl von den Dolmetschersprechstellen gegeben wird 68 Eingang der ersten Sprechstellenlinie der aus maximal 30 Sprechstellen zusammengesetzt werden kann 36 INTERPR I Eingang f r die
24. ansonsten wird es nicht m glich sein die bersetzte Sprache zu h ren ber Kopfh rer Auf den Dolmetschsprechstellen befinden sich die Jack Stecker immer auf HEADPHONES Benut zung der Kopfh rer abgesehen von der Parametereinstellung CONSOLE OUT JACK der Zentrale DMU 6100 eine Einstellung die nur f r Vorsitzende und Abgeordnetensprechstellen gilt wohinge gen die Lautst rke immer regulierbar ist zwischen Null und dem maximal eingestellten Niveau der zentralen Einheit OBERES PANEEL Es gibt zwei Lautst rkentasten 2 Auswahltasten und einen zweifarben LED deren Funktion von der Betriebsmodalit t abh ngt Abgeordneter Vorsitzender Dolmetscher und von der Konfiguration der Zentrale DMU 6100 INTERNER LAUTSPRECHER Die Tasten f r die Lautst rkkontrolle erlauben auch nicht die Regulierung zwischen Null und dem maximal eingestellten Niveau der Zentrale DMU 6100 Der Lautsprecher ist w hrend der Simultan bersetzung immer abgeschaltet wenn das Mikrofon der Sprechstelle angeschaltet ist und auf HEADPHONES Einstellung wenn die Kopfh rer in einer der zwei Jack Stecker eingef gt sind 66 LAUTSTARKENTASTEN g Diese Tasten erlauben die Regulierung der Lautst rke der internen Lautsprecher und des Ausgang sniveaus der 2 Jack Stecker Die Regulierung kann mit sukzessivem Druck oder durch kontinuierli ches Dr cken der Taste vollzogen werden AUSWAHLTASTEN gro und klein Siehe die folgenden Parag
25. cosi pure durante la modalit di traduzione sequenziale quando una console interprete attivata tacitando i delegati RIEPILOGO SEGNALAZIONI TRAMITE LED LED ROSSO LAMPEGGIANTE SOLO 3 SECONDI si tenta invano l attivazione del microfono l anello luminoso non si accende II microfono non si attivato e non si nemmeno ottenuta la prenotazio ne perch stato raggiunto il limite massimo di console delegato attivabili contemporaneamente ed anche la prenotazione non disponibile oppure un presidente usufruisce della PRIORITA o ha effettuato il RESET LED VERDE si tenta invano l attivazione del microfono l anello luminoso non si accende perch stato raggiunto il limite massimo di console delegato attivabili contemporaneamente ma il LED verde acceso segnala che la prenotazione stata accettata LED ROSSO il microfono della console attivato l anello luminoso acceso LED ROSSO LAMPEGGIANTE la console delegato stata attivata ma il microfono momenta neamente spento MUTE Possibili motivi stato premuto il tasto piccolo B MUTE oppure un presidente usufruisce della PRIORITA in tal caso il delegato non potr parlare ma solo disattivare eventualmente il proprio microfono o attendere che il presidente annulli la PRIORITA LED GIALLO LAMPEGGIANTE l interprete ha richiesto di parlare lentamente SPEAK SLOWLY in modalit di traduzione simultanea oppure l interprete attivo in modalit di traduz
26. dell apparecchio sono collegate a terra tramite il cavo di alimentazione Un apparecchio avente costruzione di CLASSE deve essere connesso alla presa di rete con un collegamento alla terra di protezione d Accertarsi che il cavo di alimentazione dell apparecchio non possa essere calpestato o schiacciato da oggetti al fine di salvaguardarne la perfetta integrit e Per evitare il rischio di shock elettrici non aprire mai l apparecchio all interno non vi sono parti che possono essere utilizzate dall utente 2 2 ALIMENTAZIONE TRAMITE ALIMENTATORE ESTERNO a Alimentare il prodotto utilizzando solo l alimentatore dedicato verificare che la tensione della vostra rete corrisponda quella di targa dell alimentatore e che il valore edil tipo continua o alternata di tensione d uscita dello stesso corrisponda a quella d ingresso del prodotto in caso contrario rivolgersi ad un rivenditore RCF verificare inoltre che l alimentatore non sia stato danneggiato da eventuali urti o sovraccarichi b Latensione di rete alla quale connesso l alimentatore ha un valore sufficientemente alto da costituire un rischio di folgorazione per le persone prestare attenzione durante la connessione alla rete es non effettuarla con le mani bagnate e non aprire mai l alimentatore Accertarsi che il cavo dell alimentatore non sia o possa essere schiacciato da altri oggetti prestando particolare attenzione alla parte del cavo vicino alla spina ed al punto dove
27. e gli interpreti 40 secondi per i presidenti mantenendo premuto il tasto SET per 3 secondi all accensione dell unit centrale DMU 6100 op pure dopo aver riavviato il sistema premendo il tasto ENTER nel men SET CONSOLE NON OPERATIVA IN BY PASS Nel caso una console non funzioni piu correttamente sempre consigliabile scollegarla dalla linea se ci non immediatamente possibile ad esempio data la distanza tra una console e l altra e la lunghezza limitata dei cavi la console guasta pu essere resa non operativa pur rimanendo colle gata alla linea lasciando quindi transitare i segnali audio e dati da e verso le altre console Impostazione dei microinterruttori per la disattivazione della console 1 ON 2 OFF Console non operativa in by pass E necessario riavviare il sistema per rendere effettiva la nuova impostazione CAVO SPECIALE A 10 POLI PER CONSOLE CONNETTORE RJ a 10 poli 1 ROSSO 2 NERO 3 GRIGIO 4 BLU 5 ARANCIONE 6 BIANCO 7 SCHERMO 8 GIALLO 9 MARRONE 10 VERDE pin pin 1 48V alimentazione c c 6 segnale audio ritorno 2 massa alimentazione 7 massa digitale 3 trasmissione e ricezione dati 8 microfono 4 trasmissione e ricezione dati 9 microfono 5 segnale audio ritorno 10 massa microfono 24 CAVO AUDIO BILANCIATO CON CONNETTORI XLR pin 1 massa 2 segnale 3 segnale ESEMPIO CONNESSIONI
28. erste bersetzersprechstelle 37 LINE 2 Eingang der zweiten Sprechstellenlinie f r maximal 30 Sprechstellen 38 INTERPR II Eingang f r die zweite bersetzersprechstelle 89 INTERPR LINE TERMIN Mikroschalter und II f r die Aktivierung der Eing nge INTERPR I und INTERPR II roy Sprechstelle Dolmetscher angeschlossen Sprechstelle Dolmetscher nicht angeschlossen 40 Anschluss mit Schmelzsicherung f r den Strom aus dem Netz 100 240 V AC 41 Klemme f r die Erdung des Ger ts 42 Reservierter Platz f r die optionale Karte DEC 6104 57 HUSLNAC MEN DMU 6100 Nachdem das Ger t angeschaltet wird erscheint auf dem Display LCD f r einige Sekunden die Inschrift G Die Version der Firmenware z B 1 0 wird visualisiert Dann startet das System den Initialisierungsprozess und fragt alle Sprechstellen ab Delegierter Pr sident Dolmetscher Zu diesem Zeitpunkt geht der Leuchtring einer jeden Sprechstelle an Die Dolmetschersprechstellen haben einen separaten Eingang sie k nnen nicht an die beiden Leitun gen LINE 1 und 2 angeschlossen werden Wenn es mehr als 3 Vorsitzende gibt chairman error oder mehr als 30 Sprechstellen f r jeweils eine Linie delegate error ist das Initialisierungsverfahren blockiert und die Leuchtringe an den Sprechstellen signalisieren an welcher Stelle der Linie eine falsch eingestellte Sprechstelle sein k nnte Je nach Art des Fehlers wird auf dem chai
29. impostazione del modo operativo di ciascuna console microfonica si effettua tramite i 2 microinter ruttoripresenti sul pannello posteriore 1 2 OFF OFF DELEGATO ON ON PRESIDENTE OFF ON INTERPRETE ON OFF console non operativa L impostazione di tutte le console DMS 6410 va effettuata prima che l unit centrale DMU 6100 configuri le basi diversamente potr aver luogo anche durante il funzionamento ma la nuova impo stazione avr effetto solo ad una nuova accensione del sistema oppure reinizializzandolo entrando nel men di configurazione SET e premendo poi ENTER CONNESSIONE CONSOLE DELEGATI PRESIDENTI Sul pannello posteriore sono presenti 2 connettori RJ a 10 poli per le connessioni tra console e con l unit centrale DMU 6100 La connessione avviene mediante apposito cavo speciale a 10 poli in dotazione La presa IN ingresso posta a destra si collega al connettore sinistro OUT uscita della console precedente oppure ad una delle 2 uscite linea 1 o linea 2 dell unit centrale DMU 6100 nel caso si tratti della prima base di una linea La distribuzione ed il numero delle console sulle 2 linee arbitraria purch siano al massimo 30 per linea CONNESSIONE CONSOLE INTERPRETI Le 2 console interpreti se utilizzate andranno collegate alle 2 prese dedicate dell unit centrale DMU 6100 17 IMPORTANTE TERMINAZIONE DELLE LINEE Per una corretta terminazione d
30. max 15 dB 2 1 kHz nominal 7 dBu THD lt 0 1 max 10 dBu THD 0 5 25 Hz 20 kHz 1000 gt 90 dBA MIC LINE A MIC LINE B PLAY die Sprechstellen nominal 7 dBu THD lt 0 1 max 10 dBu THD 0 5 45 Hz 20 kHz 1000 gt 85 dBA MIC LINE A MIC LINE B PLAY CONSOLES Ausgang 0 0 SYSTEM doppeltes RCA Ausgangsniveau Frequenzreaktion 3 dB Widerstand des Ausgangs 1 kHz Verh ltnis Signal Ger usch Audioeing nge die den Ausg ngen zugeschickt werden 0 0 LINE 1 and LINE 2 OUTPUTS 2 x mono RCA Ausgangsniveau Frequenzreaktion 3 dB Widerstand des Ausgangs 1 kHz Verh ltnis Signal Ger usch Audioeing nge die den Ausg ngen zugeschickt werden Ausgang INSERT OUT MIC UNIT SPKR mono RCA Ausgangsniveau Frequenzreaktion 3 dB Widerstand des Ausgangs 1 kHz Verh ltnis Signal Ger usch Audioeing nge die den Ausg ngen zugeschickt werden Verst rker MONITOR intern Leistung Kopfh rerausgang jack 6 3 mm frontales Panneel Frequenzreaktion 3 dB Verh ltnis Signal Ger usch berwachte Audioeing nge Anschl sse EURO zu 2 Pole Eing nge Ausg nge Ingressi MIC LINE INPUT A CMD IN MIC LINE INPUT B CMD IN CHIME COMMAND Aktivierung Max Spannung max Strom Kontrolleingang der Fernlautst rke REMOTE LAUTSTARKE CONTROL Nutzender Potentiometer Max Spannung max Strom SLOWLY reiner Kontakt n a Max Spannung max Strom RJ Anschl sse LINE 1 LINE 2 INPR
31. note the 2 channels are summed as a mono signal This input is disabled when in REC mode see point 5 PLAY REC selection key 25 TELECONF IN FROM audio input and OUT TO audio output for teleconference RCA connectors 26 SYSTEM double mono audio output RCA connectors useful to record the same signal of the MAIN OUT output signal that depends on the system configuration and input signals This output is disabled when in PLAY MODE see point 5 PLAY REC selection key INSERT MIC UNIT SPKR Audio input IN output OUT RCA connectors to insert an optional signal processor for the console loudspeakers without a signal processor it is necessary to short circuit the output to the input through either an RCA patch cable or a jumper link LINE 1 and LINE 2 Q O audio outputs on RCA connectors Each output sends the signal of the relevant console line each made of max 30 consoles PRESENCE CONTROL MAIN OUT presence tone control FLAT linear frequency response EQ equalized signal 80 LINE LEVEL MAIN OUT main audio output on XLR plug 31 CHIME LEVEL Chime volume level control REMOTE VOLUME CHIME SPEAK LINE1 INTERPR I LINE 2 INTERPR D CONTROL ce ax Bi B Y comm Li Lei Gee 30 Ze 5 0 0 6 0 62 REMOTE VOLUME CONTROL Port for the MAIN OUT remote volume control non supplied suggested 22k type B potentiometer GI CHIME COMMAND Port for the chime external activa
32. reached When a delega te turns its microphone off the booked microphone will automatically turn on default Delegate booking function is off The SET key allows you to enter and edit the configura tion menu If pressed once for a while the LCD displays To enter the configuration menu it is necessary to press and hold the SET key for at least 3 seconds first Then press the SET key repeatedly to scroll the following parameters INTERPRETATION e A amp B INPUT MODE e VOX CMD INPUT A e VOX CMD INPUT B e CHIME ON CHAIRM e CONSOLE OUT JACK Use the keys W to change values After changing values press ENTER to confirm and save and exit After pressing ENTER to save the new settings the system will be rebooted and the discussion in progress will be interrupted INTERPRETATION Interpretation mode setting sequential simultaneous off Sequential translation when an interpreter console turns on note the other interpreter console automatically tur ns off the translated language will be sent to all the 3 system audio outputs console lines MAIN OUT and the audio output for teleconference When the interpreter console turns off the mixed signal of all consoles IN A IN B IN PLAY and the chime will be sent to all the 3 system audio outputs Simultaneous translation when an interpreter console tur ns on note the other interpreter console automatically tur ns off the translated l
33. schon vor der Aktivierung der Dolmetscher an sind SIGNAL BERSICHT DURCH LED ROTES LED Das Mikrofon der Sprechstelle ist aktiviert der Leuchtring ist an ROT BLINKENDES LED Die Dolmetschsprechstelle ist aktiviert worden aber das Mikrofon ist ge genw rtig und gewollt aus MUTE wegen des Drucks auf der gro en Taste A GELB BLINKENDES LED Der Dolmetscher hat in der Ausf hrung Simultan bersetzung darum gebe ten langsam zu sprechen SPEAK SLOWLY Das LED und der Leuchtring blinken die Kommunikation mit der Zentrale ist l nger als 30 Sekunden unterbrochen In solch einem Fall bleibt das Mikrofon an bis der Dolmetscher es ausschaltet und es wird nicht m glich sein es neu zu starten bis die Kommunkation mit der Zentrale wiederhergestellt ist Der LED und der Leuchtring gehen aus ohne dass eine Taste gedr ckt wird der andere Dolmetscher hat sich eingeloggt CONSOLE CHECK ON REBOOT Bei Anschalten des Systems oder nach Neustart durch Taste ENTER des SET Men s der Zentrale DMU 6100 gehen die Leuchtringe aller Sprechstellen nacheinander an angefangen von denen die der Zentrale am nahesten sind Geht ein oder mehrere Leuchtringe nicht an deutet dies auf ein Problem in der Leitungsstrecke direkt hinter der letzten Sprechstelle mit dem aktiven Leuchtring hin Bei den Sprechstellen f r Abgeordnete oder Dolmetscher bleiben die Leuchtringe f r 2 Sekunden an w hrend die Leuchtringe bei den Vorsitzenden 4 Sekunden aktiv sind die
34. tung deaktivieren indem man den zugeh rigen Mikroschalter auf der Zentrale DMU 6100 auf ON schaltet JACK STECKER Auf den zwei Seiten der Sprechstelle DMS 6410 befinden sich 2 Jack Ausg nge 3 5 mm 1 8 einer links der andere rechts Ihr Ausgangssignal h ngt von der Konfiguration der zentralen Einheit DMU 6100 und der Betriebsmo dalit t der Station Abgeordneter Vorsitzender Dolmetscher ab M gliche Konfigurationen sind folgende Parameter CONSOLE OUT JACK im Men SET HEADPHONES Das Signal im Ausgang wird f r die Nutzung der Kopfh rer optimiert durch Einf gen der Kopfh rer wird der interne Lautsprecher ausgeschaltet und die Lautstarke kann mit den jewei ligen Tasten zwischen 0 und dem maximal eingestellten Wert auf der Zentrale DMU 6100 reguliert werden RECORDING Das Signal im Ausgang wird f r die Nutzung eines Aufnahmeger ts optimiert und durch Einf gen eines der 2 Jacks wird der Lautsprecher nicht deaktiviert Die Kontrolle der Lautstar ke wird befahigt und kann zwischen ca 30 und 100 eingestellt werden aber die Lautstarke kann nicht auf Null heruntergedreht werden Die Lautstarkeneinstellung hat auf der Zentraleneinheit DMU 6100 keine Wirkung DISABLED Auf den Ausg ngen Jack gibt es kein Signal nur f r Vorsitzende oder Abgeordnete Der interne Lautsprecher funktioniert hingegen Wenn die Simultan bersetzung vorgesehen ist behalten Sie den Parameter CONSOLE OUT JACK auf HEADPHONES
35. un presidente preimpostato campanello disabilitato sull interven to con priorit di un presidente CONSOLE OUT JACK Impostazione uscite jack delle console solo delegati e presidenti preimpostato Sulle prese jack di ciascuna console presente lo stesso segnale di ritorno per l altoparlante quando si utilizzano le cuffie l altoparlante disattivato Sulle prese jack di ciascuna console presente il se gnale per l eventuale collegamento di un registratore l altoparlante non disattivato Sulle prese jack di ciascuna console non presente al cun segnale l altoparlante non disattivato Se previsto l utilizzo della traduzione simultanea mantenere il parametro CONSOLE OUT JACK su HEADPHONES altrimenti non sar possibile IMPORTANTE ascoltare la lingua tradotta tramite cuffie i Nelle console per interpreti le prese jack sono sempre in modalit HEADPHONES uso cuffia a prescindere dall impostazione del parametro CONSOLE OUT JACK Premendo il tasto IN VOLUME si entra nel men di impostazione dei volumi degli ingressi premendolo ripetutamente si hanno i seguenti parametri a rotazione Usare i tasti A e W per modificare livello massimo 16 livello preimpostato 10 livello 0 MUTE Volume delle console presidenti e delegati Volume delle console interpreti Volume dell ingresso MIC LINE INPUT A con presa XLR Volume dell ingresso MIC LIN
36. utilizzabili per la registrazione L uscita A riporta il segnale presente all ingresso A 15 l uscita B il segnale presente all ingresso B 22 4 Ingresso audio stereo PLAY su connettore RCA il segnale convertito in mono L ingresso disabilitato in modalit REC vedi punto 5 tasto commutazione PLAY REC 25 TELECONF Ingresso IN FROM ed uscita OUT TO audio per teleconferenza su connettori RCA 26 Doppia uscita audio mono SYSTEM su connettori RCA utilizzabili per la registrazione del segnale presente all uscita MAIN OUT che dipende dalla configurazione e dai segnali d in gresso del sistema L uscita disabilitata in modalit PLAY vedi punto 5 tasto commutazione PLAY REC 67 INSERT MIC UNIT SPKR Ingresso uscita OUT audio con connettori RCA per l inserimento di un processore di segnale opzionale per gli altoparlanti delle console senza processore occorre cortocircuitare l ingresso e l uscita tramite un ponticello apposito od un cavo corto con connettori RCA Uscite audio LINE 1 e LINE 2 su connettori RCA che riportano separatamente i segnali delle due linee con massimo 30 console ciascuna PRESENCE CONTROL Controllo toni presenza dell uscita MAIN OUT FLAT risposta lineare segnale non modificato EQ segnale equalizzato Uscita audio principale LINE LEVEL MAIN OUT con connettore XLR CHIME LEVEL Controllo volume del campanello Chime REMOTE VOLUME CHIME SPEAK LINE1 INTE
37. versorgen sichern Sie ab dass alle Stecker richtig angeschlossen sind und dass die Spannung ihres Stromnetzes mit der ausgewiesenen Spannung des Apparats bereinstimmt Falls dem nicht sein sollte wenden Sie sich an den RCF Verkaufer Die Metallteile des Ger ts sind mit der Erde ber ein Stromkabel verbunden F r den Fall dass die Steckdose die Verbindung zur Erde nicht gew hrleistet wenden Sie sich an einen ausgebildeten Elektriker der das Ger t an die Erde mit einer daf r vorgesehenen Klemme verbindet d Sichern Sie sich ab dass das Stromkabel nicht mit F en getreten oder von Gegenst nden zerquetscht werden kann damit ein perfekter Zustand gesichert werden kann e Um einen Elektroschock zu vermeiden ffnen Sie das Ger t niemals im Innern gibt es keine Gegenstande die vom Nutzer anderweitig verwendet werden k nnten 2 2 Stromversorgung ber externen Versorger a Das Ger t darf nur mit Strom aus dem hierf r vorgesehenen Versorger betrieben werden Stellen Sie sicher dass die Spannung Ihres Netzes mit der Kennzeichnung auf Ihrem Ger t bereinstimmt und das der Grad und die Art stetig oder sich ndernd der Austrittsspannung mit der Eintrittsspannung des Ger ts bereinstimmt Sollte dies nicht der Fall sein wenden Sie sich an Ihren RCF Einzelh ndler vergewissern Sie sich dar ber hinaus dass die Stromversorgung nicht durch Aufprall oder berlastung beschadigt ist b Die Spannung des Stromnetzes an d
38. 27 dBu 4 dBu 13 dBu S ttigung gt 20 dBu THD 0 5 gt 85 dBA nominal 7 dBu max 12 dBu THD 0 5 Widerstand 1 kHz 9 kO Frequenzreaktion 3 dB 50 Hz 20 kHz am Ausgang MAIN OUT Verh ltnis Signal Ger usch gt 85 dBA TELEKONF Eingang IN FROM mono RCA Eingangsniveau MAIN OUT 0 lt 0 1 nominal 7 dBu max 12 dBu THD 0 5 96 Widerstand 1 kHz 8 kO Frequenzreaktion 3 dB 135 Hz 20 kHz am Ausgang MAIN OUT Verh ltnis Signal Ger usch gt 85 dBA Eingang INSERT IN MIC UNIT SPKR mono RCA Eingangsniveau 1 einziger Verbindungseingang Widerstand 1 kHz Frequenzreaktion 3 dB Verh ltnis Signal Ger usch Uscita MAIN OUT XLR 3M bilanciato Ausgangsniveau Kontrolle Presence control Ausg nge 0 0 A und B 2 x mono RCA Ausgangsniveau Frequenzreaktion 3 dB Widerstand des Ausgangs 1 kHz Verh ltnis Signal Ger usch Audioeing nge den Ausg ngen zugeschickt Ausgang TELEKONF OUT TO mono RCA Ausgangsniveau Frequenzreaktion 3 dB Widerstand des Ausgangs 1 kHz Verh ltnis Signal Ger usch Audioeingange die den Ausg ngen zugeschickt werden nominal 4 dBu max Niveau der Kopfh rer der Sprechstel le 1 V su 150 THD 0 5 max 11 dBu aktiver Limiter THD lt 1 96 an den Kopfh rerausg ngen der Sprechstellen 20 kQ 170 Hz 16 kHz to console headphones outputs gt 80 dBA nominal 0 dBu THD lt 0 1 max 20 dBu THD 0 5
39. 410 are connected by means of special 10 pole cables a 2 5 m cable is included for every console MAIN FEATURES e Standard system up to 60 consoles DMS 6410 2 lines 30 consoles per line connected in daisy chain e Expanded system up to 180 consoles DMS 6410 6 lines 30 consoles per line connected in daisy chain The further 120 consoles can be added by installing the optional board DEC 6104 into the central unit DMU 6100 and connecting the external power supply unit DPS 6202 2 aux inputs A and B with XLR sockets each configurable by means of DIP switches PHANTOM MIC LINE HIGH PASS and with a gain control and an enable mute command Audio input PLAY and audio output SYSTEM for recording Audio input and output for teleconference Simultaneous sequential translation 1 translated language Each console can be set to 1 of the 3 available modes chairman max 3 delegate interpreter max 2 Chairmen have no limits about their microphone activation and can also mute disable all delegate consoles and cancel their bookings If 2 interpreters are present only one will be allowed to speak 1 translated language only Backlit LCD and function keys to enter the software menus and edit e Operating mode max number of activated delegates max queue length of the delegates booking etc Configuration priority level among inputs A B and the system VOX function on inputs A B etc Volume levels
40. C LINE INPUT A VOX innerer Kreislauf der ein bestehendes Audiosignal an einen Eingang weiterleitet voreingestellt Der Eingang A ist aktiviert wenn der ex terne Befehl abgeschlossen wird Befehl Aktivierung oder wenn das Zeichen automatisch festgestellt wird akti ves VOX Der Eingang A wird aktiviert wenn der externe Befehl abgeschlossen wird Befehl Aktivierung ausgeschal tetes VOX Der Eingang A wird aktiviert wenn der externe Befehl offen bleibt Befehl mute und wenn das Signal auto matisch festgestellt wird angeschaltetes VOX Der Eingang A wird aktiviert wenn der externe Befehl offen bleibt command mute und wenn das Signal automatisch entnommen wird VOX CMD INPUT vox Einstellung und Befehl des Audioeingangs MIC LINE INPUT B voreingestellt Die X Einstellungen sind identisch zu den vorher gehenden f r den Ein gang MIC LINE INPUT A Paramter VOX CMD IN PUT A aber sie beziehen sich auf den Nutzen des Eingangs MIC LINE INPUT B 1 CHIME ON CHAIRM vorrangige Signaleinstellung Glocke der Vorsitzendensprechstelle Die Glocke chime hat f r den Vorsitzenden die F hi gkeit Vorrangig zu intervenieren voreingestellt Die Glocke wird deaktiviert dies betrifft die vorrangige Intervention durch den Vorsitzenden CONSOLE OUT JACK Einstellungen der Jack Ausg nge der Sprechstellen nur Abgeordnete und Vorsitzende voreingestellt
41. E INPUT B con presa XLR Volume dell ingresso PLAY Volume dell ingresso per teleconferenza 14 Premendo il tasto OUT VOLUME si entra nel men di impostazione dei volumi delle uscite premen dolo ripetutamente si hanno i seguenti parametri a rotazione Usare i tasti A e W per modificare livello massimo 16 livello preimpostato 10 livello 0 MUTE Volume degli altoparlanti interni delle console Volume dell uscita audio principale MAIN OUT MESSAGGI D ERRORE Dalla visualizzazione dell errore si esce premendo il tasto ENTER Durante l indirizzamento CHRM INIT ERROR sono presenti piu di tre console presidenti nel sistema DEL INIT ERROR sono presenti pi di 30 console in una linea N B se nell unit centrale DMU 6100 si invertono le connessioni delle linee delegati presidenti ed interpreti il sistema NON in grado di rilevarlo quindi non vi alcuna segnalazione sul display LCD Durante il funzionamento CONSOLE ERROR una console presidente o delegato non funziona pi esempio linea 2 posizione 15 CONSOLE ERROR una console interprete non funziona pi esempio interprete nr 2 La posizione 1 la prima console di una linea collegata direttamente all unit centrale DMU 6100 i la posizione 30 l ultima console di una linea Nel caso vi siano piu avarie il display LCD visualizza comunque un solo errore alla volta dall accen sione dell apparecchio
42. ELB BLINKENDES LED Der Dolmetscher bittet in der Ausf hrungsart der Simultan bersetzung oder nachfolgenden bersetzung darum dass langsam gesprochen wird SPEAK SLOWLY und das Mikrofon der Abgeordnetensprechstelle ist vor bergehend abgeschaltet DAS LED und der Leuchtring gehen aus ohne dass der Abgeordnete einschreiten muss indem er eine Taste dr ckt Die MIC AUTO OFF Funktion hat das Mikrofon nach einiger Zeit automatisch ausgeschaltet oder ein Vorsitzender hat RESET eingegeben Das LED und der Leuchtring blinken die Kommunikation mit der Zentrale ist seit mehr als 30 Sekun den unterbrochen In solch einem Fall wird das Mikrofon ausgeschaltet und es ist nicht m glich es wieder einzuschalten bis die Kommunikation mit der zentralen Einheit wiederhergestellt ist 70 SPRECHSTELLENFUNKTION WENN ALS DOLMETSCHER EINGESTELLT Die Sprechstellen f r Dolmetscher funktionieren nur wenn eine der zwei bersetzungsausf hrun gen sequentiell oder simultan aktiviert werden durch Einstellung des Parameters INTERPRETA TION GroBe Taste A MIC MUTE Wenn nur einmal f r einen kurzen Moment drauf gedr ckt wird geht das Mikrofon der Sprechstelle der rote LED und der Mikrofonleuchtring an Wird erneut kurz drau fgedr ckt geht das Mikrofon aus der rote LED und der Mikrofonleuchtring gehen aus Nachdem das Mikrofon an war und wenn die Taste erneut lang gedr ckt und gehalten wird deaktiviert sich das Mikrofon vor ber
43. EPRETER I INTERPRETER II Max Spannung max Strom Mikrofon Frequenzreaktion 3 dB Verh ltnis Signal Ger usch Interner Limiter Eingriffsschwelle MIC AUTO OFF Spannung Strom Interne Verstarkerleistung Dimensionen nur die Station h p Gewicht Flexible L nge mit mic Inklusive Anschlusskabel JACK Ausg nge Max Leistung Ausf hrung Headphones Ausgangsniveau Ausf hrung Recording Frequenzreaktion 3 dB nominal 7 dBu THD lt 0 1 max 10 dBu THD 0 5 35 Hz 20 kHz 100 0 gt 85 dBA MIC LINE A und B TELECONF IN FROM der Sprechstellen nominal 0 dBu max 10 dBu Schwelle des Limiter der Sprechstellen 100 Hz 15 kHz 100 O gt 60 dBA eine einzige aktive Sprechstelle Alle Abgeordneten Vorsitzendensprechstellen einer jeden Leitung nominal 7 dBu max 10 dBu THD 0 5 25 Hz 25 kHz 100 0 285 dBA Alle die Dolmetschsprechstellen oder alle anderen Ausgange 1 W on a 4 loudspeaker THD 1 2 V RMS on 16 O 100 Hz 15 kHz gt 80 dBA Alle die Dolmetschsprechstellen oder alle anderen Ausg nge durch Kurzschluss der 2 Pole durch eine Verbindung R lt 5000 48 V dc 9mA 20 50 empfohlen 22 kO type 5 V dc 5mA 28 V dc 1 A 48 V dc 1 5 A on each LINE with 30 consoles elektrisch kardioid 200 Hz 12 kHz gt 60 dBA bis zu 32dB Uber dem Maximalniveau 20 dB 48 V dc nominal lt 20 mA max 50 mA interner Lautsprech
44. ERPRETER ON OFF by pass The console setting should be done before switching the central unit DMU 6100 on it can be done also when the system is operating but the new setting will be accepted after a system reboot DELEGATE CHAIRMAN CONSOLE CONNECTION Two 10 pole RJ sockets are present on the console rear panel for connections between 2 consoles or between consoles and the DMU 6100 central unit Connections are made through special 10 pole cables The input IN on the right is to be connected to either the output OUT on the left of the previous console of the same line or 1 of the 2 line 1 line 2 central unit outputs if the console is the first of the line Every console can be connected to either the line 1 or the line 2 the only limit is max 30 consoles per line INTERPRETER CONSOLE CONNECTION The 2 interpreter consoles if available shall be connected to the 2 dedicated central unit outputs 41 IMPORTANT LINE TERMINATION Each console line is to be terminated at its end e About delegate chairman consoles only the line last console LINE TERMINATION switch shall be pushed set to ON this switch is on the console rear panel On the other consoles the LINE TERMINATION switch shall be set to OFF Should a console that is not the last of the line have the LINE TERMINATION switch wrongly set to ON during the system reboot all previous consoles would be recognized properly their light
45. MOTE VOLUME CONTROL Potentiometer to be used as remote ctrl Max voltage max current OUTPUT SPEAK SLOWLY dry closing contact Max voltage max current RJ CONNECTORS LINE 1 LINE 2 INPREPRETER I INTERPRETER II Max voltage max current Microphone type Frequency response 3 dB S N ratio to MAIN OUT Internal limiter MIC AUTO OFF signal threshold Voltage current Internal amplifier power Dimensions base only w h d Weight Gooseneck mic length Included connection cable JACK OUTPUTS Max power headphones mode Output level recording mode Frequency response 3 dB nominal 7 dBu THD lt 0 1 max 10 dBu THD 0 5 35 Hz 20 kHz 100 0 285 dBA MIC LINE A MIC LIN B TELECONF IN FROM CONSOLES nominal 0 dBu max 10 dBu console limiter threshold 100 Hz 15 kHz 100 O gt 60 dBA 1 activated console only All DELEGATE and CHAIRMAN CONSOLES of each line nominal 7 dBu max 10 dBu THD 0 5 25 Hz 25 kHz 100 O gt 85 dBA ALL either INTERPRETER CONSOLES or ALL the OTHER INPUTS 1 W on a 4 loudspeaker THD 1 2 V RMS on 16 O 100 Hz 15 kHz gt 80 dBA ALL either INTERPRETER CONSOLES or ALL the OTHER INPUTS by shorting the 2 pins through a contact R lt 500 O 48 V dc 9mA 20 50 kO suggested 22 kO type B 5 V dc 5mA 28 V dc 1A 48 V do 1 5 A on each LINE with 30 consoles electret cardioid
46. NES The CONSOLE OUT JACK parameter affects chairman and delegate consoles only Press the IN VOLUME key to enter and edit the audio input volume levels Press the IN VOLUME key repeatedly to scroll the following parameters Use the keys A W to change values max 16 default 10 mute 0 Chairman delegate console volume Interpreter console volume MIC LINE INPUT A volume MIC LINE INPUT B volume PLAY input volume TELECONF input volume 38 Press the OUT VOLUME key to enter and edit the audio OUTPUT volume levels Press the OUT VOLUME key repeatedly to scroll the following parameters Use the keys Y to change values max 16 default 10 mute 0 Console internal loudspeaker volume MAIN OUT volume ERROR MESSAGES When an error is displayed press the ENTER key to exit During the system reboot CHRM INIT ERROR more than 3 chairman consoles have been found DEL INIT ERROR more than 30 consoles have been found in 1 line Note should the delegate chairman and interpreter lines be inverted wrongly connected to the central unit DMU 6100 the system would not be able to notice this problem therefore the LCD would not display any error message When the system is operating CONSOLE ERROR a chairman delegate console does not work any more example line 2 position 15 CONSOLE ERROR an interpreter console does not work any more example inter
47. RCF FORUM6000 SISTEMA PER CONFERENZE CONFERENCE SYSTEM KONFERENZ SYSTEM DMU rerrForufn User manual Manuale d uso Benutzerhandbuch NOTE SULLA SICUREZI D n 4 DESCRIZIONE E CARATTERISTICHE PRINCIPALI f pag 6 PANNELLO FRONTALE DMU 6100 1 D 7 PANNELLO POSTERIORE DMU 6100 D 8 MEN DMU6100 C 10 MESSAGGI D ERRORE pag 15 CONSOLE MICROFONICA DMS 6410 D n 16 DESCRIZIONE DELLA CONSOLE MICROFONICA DMS 6410 C 3 pag 17 FUNZIONAMENTO DELLA CONSOLE DMS 6410 SE IMPOSTATA COME PRESIDENTE pag 19 FUNZIONAMENTO DELLA CONSOLE SE IMPOSTATA COME DELEGATO pag 21 FUNZIONAMENTO DELLA CONSOLE SE IMPOSTATA COME INTERPRETE pag 23 TEST DELLE CONSOLE ALL ACCENSIONE DEL SISTEMA 23 CONSOLE NON OPERATIVA IN BY PASS Q 1 1 Dan 24 CAVO SPECIALE 10 POLI PER CONSOLE Dan 24 CAVO AUDIO BILANCIATO CON CONNETTORIXLR 25 ESEMPIO CONNESSIONI 1 1 pa 25 DATI TECHIO 1 pag 26 IMPORTANT NOTES page 28 DESCRIPTION AND MAIN FEATURES 7 page 30 DMU 6100 FRONT PANEL page 31 DMU6100REARPANEL 7 32 6100 page 34 ERROR MESSAGES _ 39 DMS 6410 MICROPHONECONSOLE page 40 DMS 6410 MICROPHONE CONSOLE DESCRIPTION f C page 41 DMS 6410 MICROPHONE CONSOLE SET TO CHAIRMAN page 43 DMS
48. RPR I LINE2 NTERPR II CONTROL COMMAND SLOWLY fig B Gh rm SIDE Ce _ NN IS IL ro s 9 9 62 REMOTE VOLUME CONTROL Connettore per il controllo di volume remoto fornito indica tivamente consigliato un potenziometro da 22k di tipo B dell uscita MAIN OUT 3 CHIME COMMAND Connettore per il comando esterno di attivazione del campanello chime Nota il campanello pu essere attivato tramite l impostazione ACTIVE del parametro CHIME ON CHAIRM nel men di configurazione SET anche in caso di priorit da parte di un presidente 69 SPEAK SLOWLY Uscita SPEAK SLOWLY parlate lentamente per segnalazione tramite contat to pulito interno n a max 28 V dc 1 A L avviso SPEAK SLOWLY viene segnalato tramite il LED giallo lampeggiante alle console quando si d l apposito comando dalle console interpreti 85 LINE 1 Ingresso della prima linea composta da max 30 console 6 INTERPR I Ingresso per la prima console interprete GO LINE 2 Ingresso della seconda linea composta da max 30 console 38 INTERPR II Ingresso per la seconda console interprete 39 INTERPR LINE TERMIN Microinterruttori e Il per l abilitazione degli ingressi INTERPR I ed INTERPR II Wen V console interprete presente Ve console interprete assente 10 Connettore con fusibile per l alimentazione da rete 100 240 V ac 41 Morsetto per la messa a terra dell apparecchio 42 Spazio riservato alla scheda opzi
49. TO OFF nicht aktiviert Dies gilt selbst wahrend der Vorgabe der nachgeordneten bersetzung bei Ein schaltung einer Dolmetschersprechstelle um die Abgeordneten zum Schweigen zu bringen ZUSAMMENFASSUNG DER SIGNALISIERUNGEN MITTELS LED ROTES LED BLINKT NUR 3 SEKUNDEN AUF Der Versuch das Mikrofon anzuschalten ist verge blich der Leuchtring geht nicht an Das Mikrofon hat sich nicht aktiviert und man hat nicht mal die Voranmeldung bekommen weil die maximale Anzahl gleichzeitig angeschalteter Abgeordneten sprechstellen erreicht ist und auch die Voranmeldung steht nicht zur Verf gung oder ein Vorsitzen der zieht Nutzen aus der Einstellung VORRANG oder hat RESET angeschaltet GR NES LED Der Versuch das Mikrofon zu aktivieren ist vergeblich der Leuchtring geht nicht an weil die maximale Anzahl gleichzeitig angeschalteter Abgeordnetensprechstellen erreicht ist aber das gr n aktivierte LED signalisiert dass die Voranmeldung angenommen wurde ROTES LED Das Sprechstellenmikrofon ist aktiviert der Leuchtring geht an ROT BLINKENDES LED Die Abgeordnetensprechstelle wird aktiviert aber das Mikrofon ist vor ber gehend ausgeschaltet MUTE M gliche Ursachen die kleine Taste B wurde gedr ckt MUTE oder ein Vorsitzender zieht Nutzen aus dem VORRANG in jenem Fall wird der Abgeordnete nicht reden k nnen sondern nur eventuell das eigene Mikrofon ausschalten k nnen oder darauf warten dass der Vorsitzende den VORRANG l scht G
50. Uscita TELECONF OUT TO mono RCA Livello d uscita Risposta in frequenza 3 dB Impedenza d uscita 1 kHz Rapporto segnale rumore Ingressi audio inviati all uscita 100 240 V ac 50 60 Hz 1 7 A 230 V 3 5 A 115 V 400 W T4A 250 V tipo IEC 5x20 FAA 1 pz F1A 1 pz 0 50 C 430 mm 88 mm 310 mm 5 65 kg 40 dB 50 Hz 20 kHz all uscita MAIN OUT 20 bil 9 kO sbil 23 V I max 23 mA 12 dB ott 3dB a 100 Hz 14 dBu line input guadagno nominale 54 dBu 48 dBu 14 dBu saturazione gt 0 dBu THD 0 5 gt 65 dBA 27 dBu 4 dBu 13 dBu saturazione gt 20 dBu THD 0 5 gt 85 dBA nominale 7 dBu max 12 dBu THD 0 5 9 kO 50 Hz 20 kHz all uscita MAIN OUT gt 85 dBA nominale 7 dBu max 12 dBu THD 0 5 8 kO 135 Hz 20 kHz all uscita MAIN OUT gt 85 dBA nominale 4 dBu max livello cuffie delle console 1 V su 150 THD 0 5 max 11 dBu limiter attivo THD lt 1 alle uscite cuffie delle console 20 kQ 170 Hz 16 kHz alle uscite cuffie delle console gt 80 dBA nominale 0 dBu THD lt 0 1 max 20 dBu THD 0 5 max 15 dB a 2 1 kHz nominale 7 dBu THD lt 0 1 max 10 dBu THD 0 5 25 Hz 20 kHz 1000 gt 90 dBA MIC LINE A uscita A MIC LINE B uscita B nominale 7 dBu THD lt 0 1 max 10 dBu THD 0 5 45 Hz 20 kHz 1000 gt 85 dBA MIC LINE A MIC LINE B PLAY le console
51. a MUTE da parte del presidente AI termine della PRIORITA il microfono riattivato ed il LED rosso di nuovo acceso 21 D Se un presidente attiva la funzione RESET il microfono dei delegati attivi disattivato il LED e l anello luminoso sono spenti i delegati in attesa con la prenotazione sono disattivati si spegne il LED verde e LED giallo rosso verde lampeggiante durante la traduzione simultanea indica la richiesta dell interprete di parlare pi lentamente durante la traduzione sequenziale indica l attivazione della console interprete e quindi il micro fono del delegato momentaneamente disattivato II LED giallo lampeggiante appare solo nelle console delegati con microfono attivo o in MUTE in quelle non attive o in prenotazione con LED verde acceso non succede nulla FUNZIONE MIC AUTO OFF SOLO DELEGATI Se la funzione MIC AUTO OFF stata abilitata nella configurazione dell unit centrale dopo 30 secondi continui con microfono attivato in cui non rilevata la voce del delegato il relativo micro fono disattivato automaticamente Ogni volta che il delegato riprender a parlare negli ultimi 5 secondi a sua disposizione saranno disponibili ulteriori 10 secondi prima della disattivazione del suo microfono Quando il microfono del delegato momentaneamente disattivato funzione MUTE inserita da un presidente o dal delegato stesso la funzione MIC AUTO OFF non attiva
52. ady been reached the max number of open microphones yet the green LED indicates that the booking has been accepted RED the delegate microphone is open and its light ring is lit FLASHING RED the delegate console is activated but the microphone is momentary muted MUTE function Possible reasons the B short button has been pressed MUTE or a chairman has got the PRIORITY in the latter case the delegate cannot speak but just turns its console off or waits for the PRIORITY end FLASHING YELLOW the interpreter has requested to SPEAK SLOWLY during the simultaneous tran slation or it simply indicates the interpreter console activation during the sequential translation the refore the delegate microphone is momentary muted LED and the light ring gets off without pressing any button the MIC AUTO OFF function has automa tically turned the console off after a certain time or a chairman has used the RESET command Both LED and light ring are flashing data transmission from to the central unit has failed for 30 seconds or longer Should this happen the console would be forced off and then it would not be possible to turn it on again as long as the technical problem is still present 46 DMS 6410 MICROPHONE CONSOLE SET TO INTERPRETER The 2 interpreter consoles only work if a transla tion mode sequential or simultaneous has been selected in the software parameter INTERPRE TATION A long button MIC MUTE
53. ang der Daten 8 Mikrofon 4 bermittlung und Empfang der Daten 9 Mikrofon 5 Signal Audio R ckkehr 10 Mikrofonmasse 72 AUSGEWOGENES AUDIOKABEL MIT XLR STECKER SHIELD pin 1 Masse 2 Signal 3 Signal HUSLNAC PLAY 1 12 TELECONF Stromspannung Maximal aufgenommener Strom Maximaler Verbrauch Schmelzsicherung Versicherung Andere interne Schmelzsicherungen Betriebstemperatur Ausmaf I h p Gewicht Netto Eing nge MIC LINE INPUT A B XLR 3F ausgewogen Kontrollschadenschwankung Frequenzreaktion 3 dB Widerstand 1 kHz Strom Phantom Hoher Verbindungsfilter Einschreitungsgrenze des VOX Niveau MIC MAIN OUT 0 dBu THD lt 0 1 Maximaler nominaler minimaler Schaden Verh ltnis Signal Ger usch Niveau LINE MIC PHANTOM MAIN OUT 0 dBu THD lt 0 1 Maximaler nominaler minimaler Schaden Verh ltnis Signal Ger usch Eingang PLAY doppelter RCA Eingangsniveau 1 einziger Verbindungseingang 100 240 V ac 50 60 Hz 1 7 A 230 V 3 5 A 115 V 400 W T4A 250 V IEC 5x20 type F4A 1 pc FIA 1 pc 0 50 C 32 122 F 430 mm 88 mm 310 mm 5 65 kg 40 dB 50 Hz 20 kHz am Ausgang MAIN OUT 20 bal 9 kO unbal 23 V I max 23 mA 12 dB oct 3dB cut Q 100 Hz 14 dBu Leitung input Nominalschaden 54 dBu 48 dBu 14 dBu S ttigung 0 dBu THD 0 596 gt 65 dBA
54. anguage will be sent to the console jack outputs console internal loudspeakers are off The mixed signal of all consoles IN A IN B IN PLAY and the chime will be sent to the other 2 system audio outputs MAIN OUT and the audio output for teleconference If the simultaneous translation mode is selected it will be strictly necessary to connect a reinforcement sound system to the central unit DMU 6100 LINE LEVEL MAIN OUT to allow the listening of the floor not translated language default Interpreter consoles are disabled 36 A amp B INPUT MODE mic LINE INPUT A and B priority setting default IN A IN B and the console signal are mixed IN A and IN B are interlocked each other first come first served basis IN A IN B and console signals are mixed IN A has higher priority than IN B IN A IN B and console signals are mixed IN A and IN B are mixed IN A IN B signal has higher priority than consoles IN A and IN B are mixed The console signal has higher priority than IN A IN B IN B and console signals are mixed IN A has higher priority than IN B consoles VOX CMD INPUT A MIC LINE INPUT A VOX and command setting VOX internal circuit that automatically detects the audio signal presence on an input default IN A can be opened by either an external com mand command activation or if the signal is automati cally detected VOX IN A can be
55. as no effect e DISABLED All jack outputs but interpreter consoles are disabled Console internal loudspeakers are anyway activated If the use of simultaneous interpretation is foreseen keep the CONSOLE OUT JACK parameter on HEADPHONES otherwise it will not be possible to listen to the translated language by means of headphones About the 2 interpreter consoles their jack outputs are always set to the HEADPHONES mode the volume is always adjustable from 0 to the maximum value set on the DMU 6100 central unit The CONSOLE OUT JACK parameter of the central unit affects chairman and delegate consoles only TOP PANEL There are 2 volume buttons 2 selection buttons and a bi colour LED of which function depends on the console operating mode delegate chairman interpreter and the system configuration INTERNAL LOUDSPEAKER The volume buttons allow to adjust the volume from 0 to the maximum value set on the DMU 6100 central unit The internal loudspeaker is always off when the simultaneous translation is in progress the console microphone is open headphones are connected to at least 1 jack output in HEADPHO NES mode 42 VOLUME BUTTONS These buttons can be used to adjust the internal loudspeaker volume and the jack output level The adjustment can be made step by step by pressing a button several times or continuously by press and hold a button SELECTION BUTTONS 1 short and 1 long Read
56. chweren Sch den leidet Gegenstande oder Fl ssigkeiten ins Gerat eingedrungen sind Das Ger t schweren St en ausgesetzt war 5 Falls dieses Ger t nicht lange genutzt wird entfernen Sie die Spannung des Stromkabels oder trennen Sie die externe Stromversorgung 6 Falls aus dem Produkt ungew hnlicher Geruch oder Qualm austritt schalten Sie das Ger t und den Strom sofort aus oder trennen Sie die externe Stromversorgung T Schalten Sie an dieses Produkt keine nicht daf r vorgesehenen Ger te und Zubeh r an Wenn eine Installation in der Schwebe vorgesehen ist verwenden Sie nur die daf r vorgesehenen Verankerungsstellen und versuchen Sie nicht dieses Produkt durch ungeeignete Elemente aufzuh ngen Dar ber hinaus stellen Sie fest ob die Fassung W nde Decke Struktur etc and die das Ger t verankert ist sowie die brigen Fixierungskomponenten nicht von RCF gelieferte D bel Schrauben und B gel geeignet sind die Sicherheit der Anlage w hrend der gesamten Nutzungsdauer zu gew hrleisten Denken sie hierbei an mechanische Vibrationen die normalerweise durch einen Wandler verursacht werden w rden Um die Gefahr eines Sturzes zu vermeiden ist es ratsam das Ger t nicht mit andern Bauteilen zu berlasten es sei denn auf diese M glichkeit wird ausdr cklich im Leitfaden hingewiesen 8 RCF S p A weist ausdr cklich darauf hin dass die Aufstellung dieses Ger ts nur durch professionelle hierf r ausgebildete Installate
57. d hold the SET key for 3 seconds and then ENTER for instance after adding another console DMS 6410 i3 Headphones jack socket 6 3 mm 1 4 the internal loudspeaker is off when this jack output is used Internal loudspeaker for audio monitoring of the MAIN OUT output 31 DMU 6100 REAR PANEL 15 MIC LINE audio INPUT XLR socket 16 GAIN INPUT A gain control 17 CMD IN INPUT A enable mute command Note the choice between enable or mute is made by setting the VOX CMD INPUT A parameter INPUT A DIP switches e PHANTOM ON Phantom power supply is ON OFF Phantom power supply is OFF e MIC LINE MIC Microphone input LINE High level source audio input i e CD HIGH PASS ON High pass filter inserted OFF No high pass filter 19 INPUT B DIP switches as above see INPUT A DIP switches 20 CMD IN INPUT B enable mute command Note the choice between enable or mute is made by setting the VOX CMD INPUT B para meter 21 GAIN INPUT B gain control 22 MIC LINE audio INPUT B XLR socket PA THECONF QUO WEEN QO y LINE LEVEL MAIN DUT Yr Xr ale SP outro 28 lt J JE al 603 Separated Q O audio outputs for recording The A output sends the INPUT A 15 signal the B output sends the INPUT B 22 signal 32 PLAY stereo audio input double RCA
58. e possibile disattivare momentaneamente il microfono MUTE con la medesima modalit appena descritta invece una successiva pressione rapida del tasto comporta la disattivazione completa del microfono LED spento Nella modalit di traduzione simultanea se un presidente attivasse la PRIORITA non accadrebbe nulla in quanto solo il segnale audio dell interprete inviato ai diffusori delle console Nella modalit di traduzione sequenziale l abilitazione del microfono dell interprete prioritaria ri spetto ai presidenti e delegati i quali sono temporaneamente disattivati LED giallo lampeggiante e Tasto piccolo B SPEAK SLOWLY se premuto una sola volta durante la modalit di traduzione simultanea invia una segnalazione LED giallo lampeggiante a tutte le console attive delega to presidente e lo stesso interprete come richiesta di parlare pi lentamente ed attiva l uscita SPEAK SLOWLY vedi p 34 sul pannello posteriore dell unit centrale DMU 6100 La cancellazione della segnalazione SPEAK SLOWLY si ottiene alla succesiva pressione del tasto piccolo B oppure disattivando la console interprete premendo il tasto grande A II tasto non ha alcun effetto in modalit di traduzione sequenziale in quanto i LED gialli lampeg gianti delle console attive sono gi presenti dall abilitazione dell interprete RIEPILOGO SEGNALAZIONI TRAMITE LED LED ROSSO il microfono della console attivato l anello luminoso acceso
59. e B sono miscelati ed il loro segnale prio ritario su quello delle console Il segnale delle console prioritario su quello miscelato degli ingressi A e B Il segnale dell ingresso A prioritario su quello miscelato composto dall ingresso B e le console VOX CMD INPUT A Impostazione VOX e comando dell ingresso audio MIC LINE INPUT A VOX circuito interno che rileva automaticamente la presenza di un segnale audio ad un ingresso i preimpostato L ingresso A attivato se il comando esterno viene chiuso comando attivazione o se si rile va automaticamente il segnale VOX attivo L ingresso A attivato se il comando esterno viene chiu so comando attivazione VOX non attivo L ingresso A attivato se il comando esterno rimane aperto comando mute e se si rileva automaticamen te il segnale VOX attivo L ingresso A attivato se il comando esterno rimane aperto command mute VOX non attivo VOX CMD INPUT B Impostazione VOX e comando dell ingresso audio MIC LINE INPUT B preimpostato Le impostazioni sono identi che a quelle precedenti per Lu i l ingresso MIC LINE INPUT A parametro VOX CMD INPUT A ma riferite al l utilizzo dell ingresso MIC LINE INPUT B 3 CHIME ON CHAIRM Impostazione segnalazione campanello di priorit della console presidente Il campanello chime abilitato sull intervento con PRIORITA di
60. e audio del sistema nuovamente inviato il segnale miscelato delle console IN A IN B IN PLAY ed il campanello Chime Traduzione simultanea attivata se una delle due console traduttore chiede l abilitazione e disabilita l altra la lingua tradotta dispo nibile solo sulle uscite jack per cuffie delle console gli altoparlanti interni delle console sono disattivati Alle altre 2 uscite del sistema MAIN OUT e l uscita per teleconferenza inviato il segnale misce lato delle console IN A IN B IN PLAY ed il campanello Chime Scegliendo la modalit di traduzione simultanea strettamente necessario collegare un sistema audio di rinforzo all uscita LINE LEVEL MAIN OUT dell unit centrale DMU 6100 per permettere l ascolto della lingua originale preimpostato Traduzione disattivata alle 3 uscite del siste ma linee console MAIN OUT e teleconferenza inviato il segnale miscelato delle console IN A IN B IN PLAY ed il campanello Chime 12 A amp B INPUT MODE Impostazione priorit ingressi audio MIC LINE INPUT A e B preimpostato Gli ingressi A B ed il segnale delle con sole sono miscelati Gli ingressi A e B sono interbloccati tra loro il primo in gresso attivato esclude l altro il loro segnale miscelato con quello delle console L ingresso A prioritario su quello B il loro segnale miscelato con quello dei microfoni delle console Gli ingressi A
61. e exposed to dripping or splashing No objects filled with liquid such as vases shall be placed on this apparatus 4 Never attempt to carry out any operations modifications or repairs that are not expressly described in this manual Contact your authorized service centre or qualified personnel should any of the following occur e the product does not function or functions in an anomalous way e the power supply cable has been damaged 28 e objects or liquids have got into the unit e the product has been subject to a heavy impact 5 If this product is not used for a long period switch it off and disconnect the power cable 6 If this product begins emitting any strange odours or smoke switch it off immediately and disconnect the power supply cable T Do not connect this product to any equipment or accessories not foreseen For suspended installation only use the dedicated anchoring points and do not try to hang this product by using elements that are unsuitable or not specific for this purpose Also check the suitability of the support surface to which the product is anchored wall ceiling structure etc and the components used for attachment screw anchors screws brackets not supplied by RCF etc which must guarantee the security of the system installation over time also considering for example the mechanical vibrations normally generated by transducers To prevent the risk of falling equipment do not stack multiple u
62. e il parametro MIC MODE SET UP dell unit centrale e Tasto grande A funzionamento NORMALE attiva il microfono della console si accendono il LED rosso e l anello luminoso del microfono L attivazione del microfono momentanea quando il tasto mantenuto premuto oppure stabile se il tasto pigiato una sola volta per un istante Se rilasciato o premuto di nuovo per un istante in caso d inserzione stabile si disattiva il microfono il LED rosso e l anello luminoso del microfono si spengono Se il microfono gi stato attivato in modo stabile mediante una breve pressione del tasto A comun que possibile passare ad un attivazione momentanea pigiandolo di nuovo e tenendolo premuto e Tasto piccolo B PRIORITA attiva il microfono della console con la priorit sui delegati si accen dono il LED verde e l anello luminoso del microfono viene diffuso il suono del campanello chime se attivato nel men di configurazione SET la priorit consente al presidente di tacitare per la du rata dell intervento tutti i delegati attivi ed impedisce agli altri l attivazione del microfono Quando la priorit ha termine i delegati precedentemente tacitati ritornano attivi se nel frattempo non avevano annullato la selezione gli altri delegati possono ora richiedere l abilitazione Le modalit di attivazione e disattivazione sono analoghe al tasto grande A vedi sopra E possibile passare da un attivazione NORMALE del micr
63. ed The console red light rings help to find out in which line segment there could be a console wrongly set According to the error the LCD displays chairman error delegate error After problems have been found press and hold for 3 secon ds the SET key and then press the ENTER key or turn the device off to reboot the system If all is OK the LCD displays where x y and zzz are respectively the found chairmen 0 3 interpreters 0 2 delegates 0 60 with the optional board DEC 6104 0 180 After the initial check all console red light rings are lit for 2 se conds delegates and interpreters or 4 seconds chairmen This allows to verify how many consoles and their effective places are set to either delegate interpreter or chairman Finally the LCD will display the present operating mode e g FREE DISCUSSION The operating modes will be explained in the following i paragraph about the MODE key When the LCD shows the present mode default the keys A V can be used to adjust the central unit internal loud speaker volume max 16 default 10 mute O The LCD displays Press the MODE key to enter and edit the operating mode menu IMPORTANT IMPORTANT All MODE menu parameters can be edited even if the discussion is in progress New settings are not retroactive Example if the max number of microphones that can be activated or the booking quote is changed this setting wi
64. elle linee procedere come segue Nell ultima console delegato o presidente di una linea necessario premere ON il relativo inter ruttore LINE TERMINATION posto sul retro Sulle restanti console di ciascuna linea l interruttore dovr essere in posizione OFF sollevato Nel caso che una delle console lungo la tratta abbia erroneamente l interruttore LINE TERMINATION premuto ON durante la configurazione tutte le console precedenti saranno riconosciute accensione anello luminoso mentre invece le succes sive non saranno rilevate dall unit centrale DMU 6100 e Se si utilizza almeno una console interprete sull unit centrale DMU 6100 occorre assicurarsi che il relativo microinterruttore di terminazione sia in posizione OFF interprete presente Sulla con sole interprete invece irrilevante premere o meno il relativo interruttore LINE TERMINATION e Se NON si utilizza una console interprete occorre disattivare la relativa linea non utilizzata posizio nando il relativo microinterruttore posto sull unit centrale DMU 6100 su ON PRESE JACK Ai 2 lati della console DMS 6410 sono presenti 2 uscite jack 3 5 mm 1 8 una a sinistra una a destra Il loro segnale d uscita dipende dalla configurazione dell unit centrale DMU 6100 e dalla modalit ope rativa della base delegato presidente interprete Le configurazioni possibili sono le seguenti parametro CONSOLE OUT JACK nel men SET e HEADPHONES
65. ellendeaktivierung nur Delegierte Aktivierung der Funktion die eine Delegiertensprechstel le automatisch nach 30 Sekunden deaktiviert wenn kein Signal anliegt voreingestellt Deaktivierung der Funktion die erlaubt eine Abgeordne tensprechstelle automatisch nach 30 Sekunden Ruhe zu deaktivieren RESERVATION NEXT Einstellung der Delegiertenanmeldung Zugelassene Voranmeldung an max 1 n Abgeordnete wobei n eine Zahl zwischen 1 und 9 annehmen kann nachdem die maximale Anzahl aktiver Abgeordneter ver sammelt ist Wenn ein Abgeordneter das eigene Mikrofon deaktiviert wird die zuerst angemeldete Sprechstelle au tomatisch bef higt number of open microphones has alre ady been reached When a delegate turns its microphone off the next microphone the first of the queue will automa tically turn on 9 Einen einzelnen Abgeordneten wird die Anmeldung zugewilligt nachdem er die maximale Anzahl aktiver Abgeordneter zusammengetragen hat Wenn ein Abge ordneter sein eigenes Mikrofon deaktiviert ist die voran gemeldete Sprechstelle automatisch aktiviert voreingestellt Deaktivierung der Voranmeldung sfunktion der Abgeordneten Durch die Taste SET gelangt man auf das Konfigura tionsmen wo man einen Moment drauf dr ckt An schlieBend gelangt man auf den Display LCD und es erscheint der folgende Text Um auf das Men zu gelangen ist es erstmals n tig die Taste SET f r mindestens 3 Sekunden gedr ckt zu hal
66. eln induzierte Auftreten von Gerauschen zu vermeiden die Signale von den Mikrophonen oder Anschlusssignalen bermitteln z B OdB nutzen Sie nur abgeschirmte Kabel und vermeiden Sie es folgende Objekte in die N he zu stellen Ger te die hochintensive Magnetfelder erzeugen z B Wandler mit einer hohen Leistungskraft Netzkabel e Anschl sse von Lautsprechanlagen Sicherheitshinweis e Verschlie en Sie nicht die L ftungsgitter der Einheit Stellen Sie das Ger t nicht in die N he von Hitzequellen und sorgen Sie daf r dass die Luft zirkuliert berlasten Sie dieses Ger t nicht allzu lang beranspruchen Sie nie die Schaltungseinheiten Tasten Einstellkn pfe etc Verwenden Sie nie L sungsmittel Alkohol Benzin und andere Mittel um die externen Teile der Einheit zu reinigen Professionelles Audiosystem das nur f r Festinstallation vorgesehen ist 53 RCF bedankt sich f r den Kauf dieses Produkts welches zur Gew hrung eines hohen Standards und einer hohen Zuverl ssigkeit entwickelt wurde Beschreibung und Haupteigenschaften Das RCF Forum 6000 System ist ein Konferenzsystem das aus einer Zentrale der DMU 6100 und bis zu 60 DMS 6410 Sprechstellen besteht die an das Konferenzsystem angeschlossen sind expandierbar bis zu 180 Sprechstellen mit optionaler Karte DEC 6104 und Netzteil DPS 6202 Die DMS 6410 Sprechstellen wird mit einem 10 poligem Spezialkabel angeschlossen ein 2 5 Metern Kabel geh rt zum
67. en der Stromversorger verbunden ist hat einen so hohen Wert dass ein Stromschlagrisiko f r Menschen besteht Achten Sie wahrend der Einschaltung ans Netz z B dass ihre H nde nicht nass sind und ffnen Sie nie den Stromversorger Vergewissern Sie sich dass das Stromkabel nicht zerquetscht ist oder durch andere Ger te zerquetscht werden kann achten Sie besonders auf den Teil des Stromkabels nahe beim Netzstecker und auf die Stelle wo dieser aus dem Stromversorger herausragt 2 3 Informationen ber die Batterien Benutzen Sie immer wiederaufladbahre Batterien des in der Bedienungsanleitung angegebe nen Typs berpr fen Sie dass die Polarit t eingehalten wird Lassen Sie nicht zu dass es zu einem Kurzschluss der Batterien kommt z B durch Verkn p fung der beiden gegens tzlichen Pole durch ein St ck Metall Beseitigen Sie die Batterien in den daf r vorgesehenen Beh ltern durch Einhaltung der ein schl gigen kologischen gesetzlichen Normen im jeweiligen Land der Nutzung 3 Verhindern Sie dass Gegenst nde oder Fl ssigkeiten ins Innere des Ger ts eindringen denn diese k nnen einen Stromschlag ausl sen 4 Nehmen Sie am Ger t keine Eingriffe nderungen Reparaturen vor au er jene auf die ausdr cklich im Leitfaden hingewiesen wird Wenden Sie sich an autorisierte Hilfsstellen oder an ausgebildetes Personal wenn 52 das Ger t nicht funktioniert oder ungew hnlich funktioniert das Stromkabel an s
68. eordnete 3 Vorsitzende und 2 Dolmetscher sein Ein ausgebreitetes System mit DEC 6104 Karte und zus tzlichem DPS 6202 Versorger erlaubt die Verbindung von 4 weiteren Leitungen bis zu einem Umfang von 180 DMS 6410 Sprechstellen 6 Leitung x 30 Sprechstellen jede Die Einstellung des Betriebsmodus einer jeden Mikrofonsprechstelle wird zwischen den 2 Mikro schaltungen auf dem hinteren Paneel vollbracht 1 2 OFF OFF DELEGATE ON ON CHAIRMAN OFF ON INTERPRETER ON OFF by pass Die Einstellung aller DMS 6410 Sprechstellen wird vollzogen bevor die Zentrale DMU 6100 die Stationen konfiguriert andererseits kann sie auch w hrend des Betriebs vollzogen werden Die Neueinstellung zeigt jedoch nur Wirkung wenn das System erneut angeschaltet wird oder durch Neustart indem man ins Konfigurationsmen SET geht und dort auf ENTER dr ckt ABGEORDNETEN VORSITZENDEN SPRECHSTELLENANSCHLUSS Auf dem hinteren Paneel gibt es 2 RJ 10 Pol Anschl sse f r den Anschluss zwischen den Sprech stellen und mit der zentralen Einheit DMU 6100 Der Anschluss erfolgt mittels einem daf r vorgesehenen 10 Pol Spezialkabel Der Stecker IN Eingang der sich rechts befindet wird mit dem linken Anschluss OUT Ausgang verbunden oder an einer der 2 Ausgange Leitung 1 oder Leitung 2 der Zentrale DMU 6100 f r den Fall dass es sich um die erste Station einer Leitung handelt Die Ausbreitung und die Anzahl der Sprechstellen auf 2
69. er maximal Lautstarke 1 W THD lt 1 200 mm 135 mm 60 mm 1 09 kg 450 mm spezielle 10 Pole mit RJ Anschl ssen 2 5 m Lange 60 mW on 16 O 0 596 THD nominal 4 dBu 0 296 THD max 5 dBu 170 Hz 16 kHz Salvo eventuali errori ed omissioni RCF S p A si riserva il diritto di apportare modifiche senza preavviso Except possible errors and omissions RCF S p A reserves the right to make modifications without prior notice Vc0L 0801 771 5 4 4 4 RCF SpA Via Raffaello 13 42010 Reggio Emilia Italy tel 39 0522 274411 fax 39 0522 274484 e mail rcfservice rcf it
70. es See the technical specifications in the instruction manual for the maximum sound pressure the loudspeaker is capable of producing IMPORTANT NOTES To prevent the occurrence of noise on the cables that carry microphone signals or line signals for example 0 dB only use screened cables and avoid running them in the vicinity of equipment that produces high intensity electromagnetic fields for example high power transformers mains cables e lines that supply loudspeakers OPERATING PRECAUTIONS Do not obstruct the ventilation grilles of the unit Situate this product far from any heat sources and always ensure adequate air circulation around the ventilation grilles e Do not overload this product for extended periods of time Never force the control elements keys knobs etc Do not use solvents alcohol benzene or other volatile substances for cleaning the external parts of this product Professional audio equipment for fixed installation only 29 RCF S p A would like to thank you for purchasing this product which has been designed to guarantee reliability and high performance DESCRIPTION AND MAIN FEATURES RCF FORUM 6000 series is a conference system having a central unit DMU 6100 which up to 60 microphone consoles DMS 6410 can be connected to note the system can be expanded up to 180 consoles thanks to the optional board DEC 6104 and the additional power supply unit DPS 6202 Consoles DMS 6
71. gang Mic Line B mit XLR Buchse PA THECONF QO WEEN QO y LIME LEVEL MAIN DUT Yr Xr ale Sp outro 28 lt J JE al 3 Separate Audioausg nge A und B mit RCA Buchsen f r eine Aufnahme Ausgang A ber tr gt das Signal des Eingangs A 15 Ausgang B Ubertragt das Signal des Eingangs B 22 56 Stereo Eingang PLAY mit zwei RCA Buchsen das Signal wird in Mono umgewandelt Der Eingang wird ber REC deaktiviert Siehe Punkt 5 Umwandlungstaste PLAY REC 5 TELECONF Eingang IN FROM und Ausgang OUT TO f r die Telekonferenz mit RCA Buchsen Doppelter Mono Ausgang SYSTEM mit RCA Buchsen f r die Aufnahme des aktuellen Signals am Ausgang MAIN OUT Abhangig von der Konfiguration und von den Eingangssigna len Der Ausgang wird ber PLAY deaktiviert siehe Punkt 5 Umwandlungstaste PLAY REC optional signal processor for the console loudspeakers without a signal processor it is neces sary to short circuit the output to the input through either an RCA patch cable or a jumper link INSERT MIC UNIT Eingang IN Ausgang OUT mit RCA Buchsen f r das Einf gen eines optionalen Signalprozessors f r die Sprechstellenlautsprecher ohne Prozessor m ssen der Ein und Ausgang durch einen daf r vorgesehenen B gel oder ein kurzes Kabel miteinander verbunden werden Audioausgange Line 1 und Line 2 mit RCA Buchsen die die
72. gehend MUTE und das rote LED leuchtet auf wird die Taste losgelassen aktiviert sich das Mikrofon erneut und das rote LED bleibt f r l ngere Zeit an Es ist immer m glich das Mikrofon vor bergehend zu deaktivieren MUTE mit der gleichen Ausf hrung wie eben beschrieben Wird die Taste mehrmals hintereinander schnell gedr ckt f hrt dies zu einer Deaktivierung des Mikrofons LED geht aus Aktiviert der Vorsitzende bei der Simultan bersetzung den VORRANG geschieht nichts solange nur das Audiosignal des Dolmetschers den Mikrofonlautsprechern zugesendet wird Bei der nach geordneten bersetzung hat die Anschaltung des Mikrofons des Dolmetschers Vorrang im Ver gleich zu den Vorsitzenden und den Abgeordneten die vor bergehend daktiviert werden gelb blinkendes LED Kleine Taste B SPEAK SLOWLY Bei einmaligem Dr cken w hrend der Ausf hrung der Simul tan bersetzung sendet sie ein Zeichen gelb blinkendes LED an alle angeschalteten Sprech stellen Abgeordneter Vorsitzender und Dolmetscher als Aufforderung langsamer zu sprechen und aktiviert den Ausgang SPEAK SLOWLY siehe S 34 auf dem hinteren Paneel der Zentrale DMU 6100 Das L schen des Signals SPEAK SLOWLY erreicht man durch wiederholtes Dr cken der kleinen Taste B oder durch Deaktivierung der Dolmetschersprechstelle durch Dr cken der Taste A Die Taste hat keine Auswirkung auf die nachgeordnete bersetzung sobald die gelb blinkenden LED der aktiven Sprechstellen
73. giunto 8 se non prevista la prenotazione parametro dell unit centrale RESERVATION NEXT OFF il LED rosso lampeggia per 3 secondi ed il microfono non attivato b se prevista la prenotazione da 1 a 10 delegati parametro RESERVATION NEXT NEXT n NEXT si accende il LED verde premendo di nuovo il tasto si cancella la prenotazione LED verde spento II LED rosso lampeggiante per 3 secondi si accende anche quando si raggiunto il limite massimo delle prenotazioni Se il microfono gi stato attivato in modo stabile mediante una breve pressione del tasto A comunque possibile passare ad un attivazione momentanea pigiandolo di nuovo e tenendolo pre muto e Tasto piccolo B funzione MUTE disattiva momentaneamente il microfono se precedentemente attivato in modo stabile tramite il tasto grande A ed il LED rosso lampeggia Premendolo di nuovo si ripristina l attivazione del microfono ed il LED ritorna ad essere rosso fisso Durante la funzione MUTE la console delegato comunque conteggiata nella somma di tutti i microfoni aperti influente solo nel caso che sia stato fissato il limite massimo di microfoni aperti simultaneamente E possibile disattivare il microfono della console delegato premendo il tasto grande A anche quan do il microfono stato posto in MUTE Se un presidente si inserisce con la PRIORITA il microfono dei delegati attivi disattivato tempora neamente ed il LED rosso lampeggi
74. h Leuchten des gr nen LED signalisiert Von einer NORMALEN Aktivierung oder einer mit VORRANG kann auf RESET bergewechselt wer den ohne vorher deaktivieren zu m ssen Ein nachtr gliches Dr cken einer Taste groBe Taste A oder kleine B deaktiviert das Mikrofon der Sprechstelle des Vorsitzenden Wenn ein Vorsitzender bereits die VORRANG Funktion aktiviert hat oder RESET ist es nicht mehr m glich diese einzugeben auch nicht durch einen anderen Vorsitzenden Wenn ein Vorsitzender bereits die RESET Funktion aktiviert hat kann diese nicht mehr durch einen anderen Vorsitzenden bet tigt werden es ist hingegen m glich RESET zu aktivieren wenn die an deren Vorsitzenden die Funktionen NORMAL oder VORRANG angegeben haben Der gelb blinkende LED rot gr n wird nur auf dem Vorsitzenden mit aktivem Mikrofon visua lisiert e W hrend der Simultan bersetzung gibt es die Anfrage des Dolmetscher langsamer zu sprechen wider e Wahrend der Sequenz bersetzung gibt es die Aktivierung der Dolmetschersprechstelle wieder aus diesem Grund ist das Mikrofon des Vorsitzenden kurzzeitig deaktiviert AUSF HRBARE AUSWAHL A Dr cken der Taste A Dr cken Taste OFF gt gt NORMAL gt gt OFF OFF gt gt VORRANG gt or gt OFF OFF gt gt NORMAL gt gt VORRANG gt 0 or gt OFF OFF gt 0 0 gt RESET gt 0 or gt OFF OFF gt 6 gt NORMAL gt 0 0 gt RESET gt or gt
75. i un tasto si ha l uscita automa tica dal men senza che le eventuali modifiche apportate ai parametri siano state memorizzate MIC MODE SET UP Impostazione numero max di console attivabili Limitazione del numero massimo n da 1 a 6 di console delegati che possono avere contemporaneamente il micro fono attivato 1 sola console delegato con il microfono attivato ed even tuale override priorit con esclusione da parte di un altra console delegato preimpostato Discussione libera nessuna limitazione sul numero delle console delegato attivabili Disabilitazione di tutte le console dei delegati le console dei presidenti sono invece funzionanti Disabilitazione di tutte le console delegati e presidenti MIC AUTO OFF Impostazione disattivazione automatica delle console solo delegati Attivazione della funzione che consente di disabilitare au tomaticamente una console delegato dopo 30 secondi in cui non stato rilevato alcun segnale dalla capsula mic preimpostato Disabilitazione della funzione che con sente di disattivare automaticamente una console dele gato dopo 30 secondi di silenzio RESERVATION NEXT Impostazione prenotazione delegati Prenotazione consentita a max 1 n delegati dove n vale da 1 a 9 dopo aver raggiunto il numero massimo di delegati attivi Quando un delegato disattiva il proprio microfono la prima console prenotata abilitata automa ticamente IMPORTANTE A
76. ich durch erneutes langes Dr cken auf eine kurzzeitige Aktivierung umzuschwenken e Kleine Taste B VORRANG aktiviert das Mikrofon der Sprechstelle mit Vorrang f r die Abgeordneten Infolge geht das gr ne LED und der Leuchtring an und das Glockenger usch chime verbreitet sich wenn dieses im Konfigurationsmen SET aktiviert ist der Vorrang erlaubt dem Vorsitzenden w hrend der Intervention alle aktiven Abgeordneten zum Schweigen zu bringen und verhindert andere ihre Mikrofone anzuschalten Wenn der Vorrang zu Ende geht werden die zuvor zum Schweigen gebrachten Abgeordneten wieder aktiv falls sie in der Zwischenzeit nicht die Wahl zur ckgenommen haben die anderen Abgeordneten k nnen jetzt um Aktivierung bitten Die Bedingungen zur Aktivierung und Deaktivierung sind analog zur gro en Taste A siehe oben Von einer NORMALEN Aktivierung des Mikrofons durch Dr cken der Taste A kann auf eine vorrangige umgeschwenkt werden durch kurzes Dr cken auf die kleine Taste B ohne vorher deaktivieren zu m ssen Ein nachtr gliches kurzes Dr cken einer Taste groBe Taste A oder kleine B deaktiviert das Mikrofon der Pr siden tensprechstelle 67 EJ EJ E e Durch gleichzeitiges Dr cken beider Tasten A B werden alle vorher aktiven Abgeordneten auf forcierte Weise deaktiviert RESET und die Aktivierung der anderen Abgeordneten wird verhin dert Dieses Ereignis wird durch vorheriges 3 sek ndiges Blinken und sp ter durc
77. imangono accesi per 2 secondi delegati ed interpreti op pure 4 secondi presidenti ci consente di verificare quali e quante console delegati interpreti o presidenti sono state impostate A questo punto apparir sul display la modalit di funzio namento impostata es FREE DISCUSSION Le modalit verranno discusse nella descrizione del men MODE In questo menu iniziale di default se si premono i tasti e 5 modifica il volume dell altoparlante moni tor interno dell unit centrale ed il display LCD mostra la barra indicate il livello attuale livello massimo 16 livello preimpostato 10 livello 0 MUTE Tramite il tasto MODE si accede al men di impostazione della modalit IMPORTANTE La modifica di tutte le impostazioni MODE possono avvenire an che durante la discussione Le nuove impostazioni NON sono retroattive verso lo stato del sistema Ad esempio se vi una modifica al numero massimo di microfoni attivabili o delle prenotazioni possibili questa vale solo per le successive richieste di attivazione da parte delle console 10 Premere il tasto MODE ripetutamente per accedere ai seguenti parametri in rotazione e MIC MODE SET UP e MIC AUTO OFF RESERVATION NEXT Usare i tasti A e W per selezionare modificare Dopo aver modificato i parametri premere ENTER per confermare ed uscire dal men Se non si preme ENTER trascorso un certo tempo dall ultima pressione d
78. ing yellow red green LED on chairman consoles with open microphone only e During the simultaneous translation it indicates the interpreter request SPEAK SLOWLY During the sequential translation it indicates the interpreter console activation therefore the chairman microphone is momentary muted A button press button press OFF gt gt SIMPLE gt gt OFF OFF gt gt PRIORITY gt gt Off OFF gt gt SIMPLE gt gt PRIORITY gt or gt OFF OFF gt 0 0 gt RESET gt 0 or gt OFF OFF gt gt SIMPLE gt 0 0 gt RESET gt or gt OFF OFF gt gt PRIORITY gt 0 0 gt RESET gt or gt OFF OFF gt gt SIMPLE gt gt PRIORITY gt gt RESET or gt OFF RED the chairman microphone is open its light ring is lit in SIMPLE mode FLASHING GREEN FOR 3 SECONDS ONLY the chairman has just activated the RESET function GREEN the chairman has got the PRIORITY or after a RESET FLASHING YELLOW the interpreter has requested to SPEAK SLOWLY during the simultaneous tran slation or it simply indicates the interpreter console activation during the sequential translation the refore the chairman microphone is momentary muted Both LED and light ring are flashing data transmission from to the central unit has failed for 30 seconds or longer Should this happen the console would keep on operating until the chairman turns it off and
79. ion LED CODES RED the interpreter microphone is open and its light ring is lit FLASHING RED the interpreter console is on but its microphone is momentary muted MUTE function due to the A button press and hold FLASHING YELLOW the interpreter has requested to SPEAK SLOWLY during the simultaneous tran slation Both LED and light ring are flashing data transmission from to the central unit has failed for 30 secon ds or longer Should this happen the console would keep on operating until the interpreter turns it off and then it would not be possible to turn it on again as long as the technical problem is still present The LED and the light ring suddenly turn off without pressing any button the other interpreter has turned its console on CONSOLE CHECK ON REBOOT During the system reboot all console red light rings get lit quickly in sequence starting from the first console to the last of all lines If 1 or more light rings do not get lit there is probably a line pro blem after the last console having the light ring lit properly Delegate and interpreter console light rings stay on for 2 seconds chairman console light rings stay on for 4 seconds This testing time can be decupled 20 seconds for delegate and interpreter consoles 40 seconds for chairman consoles by pressing and holding for at least 3 seconds the SET key during the system reboot 47 DMS 6410 MICROPHONE CONSOLE SET TO BY PASS Shou
80. ione sequenziale ed il microfono della console delegato momentaneamente disattivato II LED e l anello luminoso si spengono senza che il delegato sia intervenuto premendo un tasto la funzione MIC AUTO OFF ha automaticamente disinserito il microfono dopo un certo tempo oppu re un presidente ha effettuato il RESET II LED e l anello luminoso lampeggiano la comunicazione con l unit centrale interrotta da pi di 30 secondi In tale evenienza il microfono verr disabilitato e non sar possibile reinserirlo fino a quando non si sar ripristinata la comunicazione con l unit centrale 22 FUNZIONAMENTO DELLA CONSOLE SE IMPOSTATA COME INTERPRETE Le console per interprete funzionano solamente se una delle 2 modalit di traduzione sequenziale o simultanea stata attivata tramite l impostazione del parametro IN TERPRETATION A e Tasto grande A MIC MUTE se premuto una sola volta per un istante si attiva il microfono della console si accendono il LED rosso e l anello luminoso del microfono Se premuto di nuovo per un istante si disattiva il microfono il LED rosso e l anello luminoso del microfono si spengono Dopo che il microfono stato attivato se il tasto viene premuto di nuovo e trattenuto in modo prolungato il microfono temporaneamente disattivato MUTE ed il LED rosso lampeggia dopo il rilascio del tasto il microfono ritorner in funzione ed il LED rosso sar acceso stabilmente E sempr
81. lari o inclinate possono provocare il ribaltamento dell assieme 10 Vi sono numerosi fattori meccanici ed elettrici da considerare quando si installa un sistema audio professionale oltre a quelli prettamente acustici come la pressione sonora gli angoli di copertura la risposta in frequenza ecc 11 Perdita dell udito L esposizione ad elevati livelli sonori pu provocare la perdita permanente dell udito Il livello di pressione acustica pericolosa per l udito varia sensibilmente da persona a persona e dipende dalla durata dell esposizione Per evitare un esposizione potenzialmente pericolosa ad elevati livelli di pressione acustica necessario che chiunque sia sottoposto a tali livelli utilizzi delle adeguate protezioni quando si fa funzionare un trasduttore in grado di produrre elevati livelli sonori necessario indossare dei tappi per orecchie o delle cuffie protettive Consultare i dati tecnici contenuti nel manuale istruzioni per conoscere la massima pressione sonora che i diffusori acustici collegati sono in grado di produrre NOTE IMPORTANTI Per evitare fenomeni di rumorosit indotta sui cavi che trasportano segnali dai microfoni o di linea per esempio OdB usare solo cavi schermati ed evitare di posarli nelle vicinanze di apparecchiature che producono campi elettromagnetici di forte intensit per esempio trasformatori di grande di potenza cavi di rete e linee che alimentano altoparlanti PRECAUZIONI D USO e N
82. ld a console get faulty it would be better to remove it from the line Yet this may not be imme diately possible a temporary solution is to disable the faulty console completely by setting its DIP switches to by pass but leaving it connected to the line allowing audio signals and data to be sent to received from the next consoles of the same line DIP switch setting to disable the console 1 ON 2 OFF By pass Reboot the system after changing the console mode to make the new setting effective SPECIAL 10 POLE CABLE FOR DMS 6410 CONSOLES 10 pole RJ connector 1 RED 2 BLACK 3 GREY 4 BLUE 5 ORANGE 6 WHITE 7 SHIELD 8 YELLOW 9 BROWN 10 GREEN pin pin 1 48 V dc power supply 6 audio return 2 ground power supply T digital ground 3 RTX data 8 microphone 4 RTX data 9 microphone 5 audio return 10 microphone ground 48 XLR CONNECTORS BALANCED SIGNAL SHIELD pin 1 ground 2 hot signal 3 cold signal PLAY 1 12 TELECONF Mains Mains max current Max power consumption Mains connector fuse Other internal fuses Operating temperature Dimensions w h d Weight net MIC LINE INPUTS balanced XLR 3F Gain range control Frequency response 3 dB Impedance 1 kHz Phantom power High pass filter VOX threshold MIC INPUT LEVEL MAIN OUT 0 dBu
83. legare l alimentatore esterno T Non collegare a questo prodotto altri apparecchi e accessori non previsti Quando prevista l installazione sospesa utilizzare solamente gli appositi punti di ancoraggio e non cercare di appendere questo prodotto tramite elementi non idonei o previsti allo scopo Verificare inoltre l idoneit del supporto parete soffitto struttura ecc al quale ancorato il prodotto e dei componenti utilizzati per il fissaggio tasselli viti staffe non fornite da RCF ecc che devono garantire la sicurezza dell impianto installazione nel tempo anche considerando ad esempio vibrazioni meccaniche normalmente generate da un trasduttore Per evitare il pericolo di cadute non sovrapporre fra loro pi unit di questo prodotto quando questa possibilit non espressamente contemplata dal manuale istruzioni 8 La RCF S p A raccomanda vivamente che l installazione di questo prodotto sia eseguita solamente da installatori professionali qualificati oppure da ditte specializzate in grado di farla correttamente e certificarla in accordo con le normative vigenti Tutto il sistema audio dovr essere in conformit con le norme e le leggi vigenti in materia di impianti elettrici 9 Sostegni e Carrelli Se previsto il prodotto va utilizzato solo su carrelli o sostegni consigliati dal produttore L insieme apparecchio sostegno carrello va mosso con estrema cura Arresti improvvisi spinte eccessive e superfici irrego
84. ll only take effect for the following activation requests 34 Press the MODE key repeatedly to scroll the following parameters MIC MODE SET UP e MIC AUTO OFF e RESERVATION NEXT Use the keys A W to change values After changing values press ENTER to confirm and save and exit If the ENTER key is not pressed after some time from the last key pressure the MODE menu automati cally will quit without saving all parameter value changes MIC MODE SET UP Max number of delegate open microphone activated console setting The max number of delegate open microphones n is limi ted from 1 to 6 1 delegate open microphone at a time only and overridden by the next delegate default No limitation free discussion All delegate consoles are forced off All consoles except interpreters are forced off MIC AUTO OFF Automatic delegate microphone turning off setting After 30 seconds of silent no signal detected by the mi crophone capsule the microphone automatically turns off default MIC AUTO OFF function is off RESERVATION NEXT Delegate booking setting Only 1 n delegates n 1 to 9 can book after the max number of open microphones has already been reached When a delegate turns its microphone off the next mi crophone the first of the queue will automatically turn on Wu IMPORTANT A Only 1 delegate can book after the max number of open microphones has already been
85. mm 1 8 jack outputs for headphones recording REAR PANEL IN 10 pole RJ input connector for the 10 pole special cable coming from the previous con sole or from the central unit DMU 6100 OUT 10 pole RJ output connector for the 10 pole special cable connected to the next console 3 DIP switches to set the console chairman Line matin delegate or interpreter 4 Line termination switch it must be pushed in the last console of a line To The Next From System Microphone Set Central Unit o Delegate Chairman Interpreter console console console 40 DMS 6410 MICROPHONE CONSOLE DESCRIPTION Every microphone console can be set to 1 of the 3 possible modes e Chairman e Delegate Interpreter A basic system without the optional board DEC 6104 can have a 2 lines each made of max 30 DMS 6410 consoles delegate chairman total 60 b 2 interpreter consoles on dedicated lines max 3 chairmen in all the system For instance there can be 57 delegates 3 chairmen and 2 interpreters An expanded system including the optional board DEC 6104 and an additional power supply unit DPS 6202 allows to connect further 4 console lines to connect up to 180 consoles 6 lines x 30 consoles each Each console is to be initially set to a mode by means of its rear panel DIP switches 1 2 OFF OFF DELEGATE ON ON CHAIRMAN OFF ON INT
86. n allows a chairman to mute all delegates having open mic and does not permit delegate console new activations When the priority function ends all delegate microphones previou sly muted will get open again if in the meantime their console activations have not been cancelled and the other delegates will be able to activate their microphones This button has 2 modes push to talk or toggle like the A long button see above button once for an instant without pressing the A button to turn off A further button momentary press ei It is possible to change the mic activation from SIMPLE A button to PRIORITY by pressing the B short i ther A or B turns the chairman microphone off 43 EJ EJ E If both buttons are pressed together at the same time a chairman will get the PRIORITY and all delegate console will be immediately forced off RESET This event is signaled by the green LED first flashing for 3 seconds then lit It is possible to RESET when in SIMPLE activation or with PRIORITY without turning the console off A further button momentary press either A or B turns the chairman microphone off When the PRIORITY function or RESET is in progress the PRIORITY cannot be got by another chairman When the RESET function is in progress it cannot be activated by another chairman while the RE SET is always possible during a SIMPLE PRIORITY activation of the other 2 chairmen e The flash
87. ne Speicherung f r das Men SET und MODE f r das Lautst rkenkontrollmen sind die Parameter jedoch gespeichert Das Dr cken der Taste ENTER im Men SET beinhaltet einen Reset des Systems mit der Folge dass die laufende Diskussion unterbrochen wird Diese Prozedur Dr cken der Taste SET f r 3 Sekunden anschlie end ENTER kann auch angewandt werden um das System warm zu starten z B nachdem eine Sprechstelle hinzugef gt wurde i3 Klinkenbuchse 6 3 mm 1 4 f r den Kopfh rer der Monitorlautsprecher ist deaktiviert bei eingestecktem Kopfh rer Interner Lautsprechermonitor um das Main Out Signal abzuh ren 55 HUSLNAC Hinteres Paneel DMU 6100 15 Audioeingang Mic Line A mit XLR Buchse 16 GAIN Regler des Eingangs A 17 CMD IN Aktivierung Mute des Eingangs A Anmerkung Die Wahl zwischen der Aktivierung oder Mute hangt von der Einstellung des Parame ters VOX CMD INPUT A ab e PHANTOM ON Phantomspeisung an OFF Phantomspeisung aus e MIC LINE MIC Mikrofoneingang LINE Lineeingang z B CD Player e HIGH PASS ON Aktivierter High Pass Filter Trittschallfilter OFF High Pass Filter deaktiviert 19 Mikroschalter f r die Konfiguration des wie oben f r Eingang A 20 CMD IN IN Aktivierung Mute des Eingangs B Anmerkung Die Wahl zwischen der Aktivierung oder Mute h ngt von der Einstellung des Para meters VOX CMD INPUT B ab 21 GAIN Regler des Eingangs 22 Audioein
88. next paragraphs about the DMS 6410 console operating modes MICROPHONE LIGHT RING The red light ring indicates that the microphone is open DMS 6410 MICROPHONE CONSOLE SET TO CHAIRMAN A chairman console is never affected by the limitation of the max number of open microphones if this function has been set Its microphone can be opened even if another chairman gets the priority i or resets all delegate consoles Its microphone cannot be opened if the central unit has not recognized the console or all chairman delegate consoles have been disabled by setting the MIC MODE SET UP parameter to ALL CONSOLE OFF e A long button SIMPLE activation the microphone gets open the red LED and the light ring get lit The microphone activation is either momentary when the button is pressed and hold push to talk mode or stable if the button is pressed once for an instant toggle mode When released in push to talk mode or pressed again in toggle mode the red LED the microphone and its light ring turn off If the microphone has already been activated in toggle mode it is still possible to change to the push i to talk mode by pressing and holding the A button B short button PRIORITY the microphone gets open with the priority over all delegates the green LED and the light ring get lit the chime plays for a while if activated in the SET configuration menu The priority functio
89. ngresso del cavo speciale a 10 poli proveniente dalla console precedente o dall unit centrale DMU 6100 OUT IN i To The Next From System OUT Connettore RJ a 10 poli per l uscita del CHARM Microphone Set Unit e E e Une termination speciale a 10 poli diretto alla console on last mic unit INTERPR successiva Microinterruttori per la configurazione della con sole come presidente delegato o interprete Pulsante di terminazione della linea da attivare console console console delegato presidente interprete nell ultima console 16 DESCRIZIONE DELLA CONSOLE MICROFONICA DMS 6410 Ciascuna console microfonica pu essere impostata su uno dei 3 possibili modi operativi presidente delegato interprete Un sistema base senza scheda d espansione DEC 6104 pu comprendere a 2 linee costituite da 30 console DMS 6410 delegato o presidente per linea totale 60 b 2 console DMS 6410 interprete collegate alle prese dedicate al massimo 3 console presidente in tutto il sistema distribuite o meno sulle 2 linee Ad esempio in un sistema base possono esservi 57 delegati 3 presidenti e 2 interpreti Un sistema espanso con scheda DEC 6104 ed alimentatore supplementare DPS 6202 permette il collegamento di ulteriori 4 linee per un totale complessivo di 180 console DMS 6410 6 linee x 30 console ciascuna L
90. nicht m glich Bei Einstellung des Parameters MIC MODE SET UP auf 1 MIC ACT O RIDE mit einem einzigen aktivem Mikrofon mit override des Folgenden hat man eine einzige aktive Abgeordnetensprechstelle auf einmal die automatisch ausgeht sobald eine andere angeschaltet wird Es ist nicht m glich das Mikrofon anzuschalten wenn der Vorsitzende RESET eingestellt hat ein Vorsitzender sich mit VORRANG eingeschaltet hat die Zentrale die Sprechstelle nicht wahrgenommen hat alle Abgeordnetensprechstellen durch den Parameter MIC MODE SET UP der Zentrale abge schaltet wurden e Grosse Taste A aktiviert das Mikrofon der Sprechstelle das rote LED und der Mikrofonleuchtring gehen an Die Aktivierung des Mikrofons ist kurzfristig wenn die Taste gedr ckt gehalten wird oder lang anhaltend wenn die Taste nur einmal kurz gedr ckt wird Wird die Taste losgelassen oder erneut f r einen Moment gedr ckt im Fall einer best ndigen Einschaltung deaktiviert sich das Mikrofon der rote LED und der Mikrofonleuchtring schalten sich aus Beim Versuch das Mikrofon zu aktivieren w hrend die maximale angeschaltete Anzahl Mikrofone schon erreicht ist passiert folgendes 8 ist die Voranmeldung nicht vorgesehen ist Parameter der Zentrale RESERVATION NEXT OFF blinkt der rote LED f r 3 Sekunden auf und das Mikrofon ist nicht angeschaltet b wenn die Voranmeldung vorgesehen ist 1 bis 10 Abgeordnete Parameter RESERVATION NEXT NEXT n
91. nits of this product unless this possibility is specified in the instruction manual 8 RCF S p A strongly recommends this product is only installed by professional qualified installers or specialised firms who can ensure correct installation and certify it according to the regulations in force The entire audio system must comply with the current standards and regulations regarding electrical systems 9 Supports and trolleys The equipment should be only used on trolleys or supports where necessary that are recommended by the manufacturer The equipment support trolley assembly must be moved with extreme caution Sudden stops excessive pushing force and uneven floors may cause the assembly to overturn 10 There are numerous mechanical and electrical factors to be considered when installing a professional audio system in addition to those which are strictly acoustic such as sound pressure angles of coverage frequency response etc 11 Hearing loss Exposure to high sound levels can cause permanent hearing loss The acoustic pressure level that leads to hearing loss is different from person to person and depends on the duration of exposure To prevent potentially dangerous exposure to high levels of acoustic pressure anyone who is exposed to these levels should use adequate protection devices When a transducer capable of producing high sound levels is being used it is therefore necessary to wear ear plugs or protective earphon
92. nterprete e quindi il microfono del presidente momentaneamente disattivato Pressione tasto Pressione tasto OFF gt 6 gt NORMALE gt gt OFF OFF gt gt PRI0RIT gt Q o gt OFF OFF gt gt NORMALE gt gt PRIORIT gt gt Orr OFF gt 0 0 gt RESET gt 0 gt OFF OFF gt gt NORMALE gt 0 0 gt RESET gt o gt OFF OFF gt gt PRIORIT gt gt RESET Q o gt OFF gt gt NORMALE gt gt PRIORIT gt gt RESET o gt OFF LED ROSSO il presidente ha il microfono attivo l anello luminoso acceso in modalit NORMALE LED VERDE LAMPEGGIANTE SOLO 3 SECONDI il presidente ha attivato il RESET LED VERDE il presidente si inserito con PRIORITA o RESET se preceduto da 3 secondi di lam peggio del LED stesso LED GIALLO LAMPEGGIANTE l interprete ha richiesto di parlare lentamente SPEAK SLOWLY in modalit di traduzione simultanea oppure l interprete attivo in modalit di traduzione sequenziale ed il microfono della console presidente momentaneamente disattivato II LED e l anello luminoso lampeggiano la comunicazione con l unit centrale interrotta da pi di 30 secondi In tale evenienza il microfono rimarr comunque abilitato fino alla disattivazione da parte del presidente e non sar possibile reinserirlo fino a quando non si sar ripristinata la comunicazione con l unit centrale
93. o aktiv z B Wenn es eine Ver nderung zur maximalen Anzahl aktivi erbarer Mikrofone gibt oder der m glichen Voranmeldungen ist diese nur g ltig f r die folgenden Aktivierungsanforderungen von Seiten der Sprechstel len 58 Dr cken Sie die Taste MODE wiederholt um zu den folgenden Parametern zu gelangen in Rotierung MIC MODE SET UP e MIC AUTO OFF RESERVATION NEXT Benutzen Sie die Tasten und Y um auszuw hlen zu ver ndern Nachdem Sie die Parameter ver ndert haben dr cken Sie zur Best tigung ENTER und verlassen Sie das Men Wenn ENTER nicht gedr ckt wird gelangt man nach einiger Zeit automatisch aus dem Men ohne dass die eventuellen Anderungen der Parameter gespeichert werden MIC MODE SET UP Einstellung der maximalen Anzahl aktivierbarer Sprechstellen Beschr nkung der maximalen Sprechstellenanzahl An zahl von 1 6 f r Delegierte die gleichzeitig das Mikrofon anhaben k nnen Eine einzige Abgeordnetensprechstellen mit aktivem Mi krofon und eventuellem override berschreiben mit der n chsten Sprechstelle HUSLNAC Voreingestellt Offene Diskussion Keine Einschrankung was die Anzahl der aktivierbaren Abgeordnetensprechstel len angeht Abschaltung aller Delegiertensprechstellen die Sprech stellen der Pr sidenten funktionieren hingegen Abschaltung aller Sprechstellen Abgeordnete und Vorsit zende MIC AUTO OFF Einstellung der automatischen Sprechst
94. ofono tramite il tasto grande A ad una con PRI ORITA premendo per un istante con il tasto piccolo B senza dover prima disattivare Un ulteriore pressio ne momentanea di un tasto grande A o piccolo B disattiva il microfono della console presidente 19 H EJ EJ EJ Ej e Premendo entrambi i tasti contemporaneamente oltre ad ottenere la PRIORITA si effet tua la disattivazione forzata di tutti i delegati precedentemente attivati RESET e si impedisce l attivazione agli altri evento segnalato dall accensione prima lampeggiante per 3 secondi e poi fissa del LED verde E possibile passare da un attivazione NORMALE o con PRIORITA a RESET senza dover prima disattivare Un ulteriore pressione momentanea di un tasto grande A o piccolo B disattiva il micro fono della console presidente Se un presidente ha gi attivato la funzione PRIORITA oppure RESET non pi possibile inserirla anche da un altro presidente Se un presidente ha gi attivato la funzione RESET non pi possibile effettuarlo da un altro pre sidente invece sempre possibile effettuare il RESET se gli altri presidenti sono attivati in modo NORMALE o con PRIORITA LED giallo rosso verde lampeggiante visualizzato solo sui presidenti con microfono attivo durante la traduzione simultanea indica la richiesta dell interprete di parlare pi lentamente e durante la traduzione sequenziale indica l attivazione della console i
95. on ostruire le griglie di ventilazione dell unit Collocare il prodotto lontano da fonti di calore e garantire la circolazione dell aria in corrispondenza delle griglie di aerazione e Non sovraccaricare questo prodotto per lunghi periodi e Non forzare mai gli organi di comando tasti manopole ecc Non usare solventi alcool benzina o altre sostanze volatili per la pulitura delle parti esterne dell unit Sistema audio professionale destinato esclusivamente ad installazione fissa el RCF S p A Vi ringrazia per l acquisto di questo prodotto realizzato in modo da garantirne l affidabilit e prestazioni elevate DESCRIZIONE E CARATTERISTICHE PRINCIPALI RCF FORUM serie 6000 un sistema per conferenze composto da un unit centrale DMU 6100 ed un massimo di 60 console DMS 6410 ad essa connesse espandibile a 180 console con scheda opzionale DEC 6104 ed alimentatore DPS 6202 La connessione delle console DMS 6410 avviene tramite dei cavi speciali a 10 poli in dotazione da 2 5 m CARATTERISTICHE PRINCIPALI n configurazione standard fino ad un massimo di 60 console suddivise su due linee separate e connesse in modo sequenziale n configurazione espansa fino ad un massimo di 180 console suddivise su 6 linee le ulteriori 120 console sono collegabili installando la scheda opzionale DEC 6104 nell unit centrale DMU 6100 ed aggiungendo un alimentatore supplementare DPS 6202 dedicato per la loro alimentazione
96. onale DEC 6104 iis el IMPORTANTE MENU DMU 6100 Dopo aver acceso l apparecchio sul display LCD appa re per qualche secondo la scritta E visualizzata la versione del firmware es 1 0 dopodich si attiva la procedura di inizializzazione che determina il riconoscimento dei vari tipi di console delegato presidente interprete in questa fase si accende l anello luminoso di ogni console Ciascuna console interprete ha un ingresso dedicato e non pu essere inserita nelle due linee LINE 1 e 2 Se sono presenti pi di 3 presidenti errore presidente o pi di 30 console per ogni linea errore delegato la procedura di inizializzazione bloccata e gli anelli luminosi sulle console consentono di indagare in quale punto delle linee potrebbe esserci una console impostata erroneamente A seconda del tipo di errore BITOre sul display LCD visualizzato presidente errore delegato Dopo aver risolto gli eventuali problemi per ripetere l inizializzazione necessario spegnere il dispositi vo oppure premere per 3 secondi il tasto SET e successivamente il tasto ENTER Se invece tutto termina a buon fine al termine della proce dura sul men appare dove x y e zzz sono rispettivamente il numero dei pre sidenti 0 3 il numero di interpreti 0 2 il numero dei delegati 0 60 o 0 180 a seconda della configurazio ne Dopo il riconoscimento gli anelli luminosi delle console r
97. opened by an external command only com mand activation VOX function is off IN A is opened if there is no external command com mand mute and the signal is automatically detected VOX IN A is opened if there is no external command com mand mute VOX function is off VOX CMD INPUT B MIC LINE INPUT B VOX and command setting default This setting is like the pre vious of INPUT A VOX CMD INPUT A but regar ding the INPUT B 7 IMPORTANT CHIME ON CHAIRM Chairman console chime setting The chime is sent when a chairman activates the PRIOR ITY default The chime is NOT sent when a chairman acti vates the priority CONSOLE OUT JACK Console jack output setting delegates and chairmen only default The signal for internal loudspeakers is also avai lable on console jack outputs for headphones When headphones are used the internal loudspeaker is off Console jack outputs provide an optimized signal for recording Console internal loudspeakers keep working when jack outputs are used No signal available on console jack outputs internal lou dspeakers are on If the use of simultaneous interpretation is foreseen keep the CONSOLE OUT JACK parameter on HEADPHONES otherwise it will not be possible to listen to the translated language by means of headphones About the 2 interpreter consoles their jack outputs are always set to HEADPHO
98. presidente interprete e dalla configurazione del l unit centrale DMU 6100 ALTOPARLANTE INTERNO tasti per il controllo del volume ne permettono la regolazione tra zero e il massimo livello impostato sull unit centrale DMU 6100 L altoparlante sempre disinserito durante la traduzione simultanea quando attivato il microfono della console quando sono inserite le cuffie in almeno una delle 2 prese jack se poste in modalit HEADPHONES 18 TASTI VOLUME di Questi tasti permettono di regolare il volume dell altoparlante interno ed il livello d uscita delle 2 prese jack La regolazione pu essere effettuata con pressioni successive od in modo continuo tenendo pre muto il tasto TASTI DI SELEZIONE piccolo e grande Vedere i successivi paragrafi inerenti alle varie modalit di funzionamento delle console DMS 6410 GHIERA MICROFONICA La ghiera dotata di un anello luminoso rosso indicante l attivazione del microfono FUNZIONAMENTO DELLA CONSOLE DMS 6410 SE IMPOSTATA COME PRESIDENTE Il presidente non soggetto all eventuale limitazione del numero di microfoni aperti contemporaneamen te L attivazione del microfono possibile anche quando un altro presidente sta utilizzando le funzioni di priorit e disattivazione delle console dei delegati Non possibile attivare il microfono se l unit centrale non ha rilevato la console oppure se tutte le con sole presidente e delegato sono disabilitate tramit
99. preter no 2 The position 1 is the first console directly connected to the DMU 6100 central unit the position i 30 is the line last console Should be present more issues the LCD would display 1 at a time only since the system reboot i It is therefore necessary to fix the first error in order to see on the display the next if present after rebooting the system This message may appear after turning the system on and after the console check when problems have oc curred during the EEPROM internal memory reading In this case all default parameters are restored and techni cal assistance is required when possible Power supply and fuse faults technical assistance required Internal 12 V power supply fault 9 Internal 24 V power supply fault External 24 V power supply fault DPS 6202 Console line 1 and 2 fuse fault Console line 3 and 4 fuse fault DEC 6104 Console line 5 and 6 fuse fault DEC 6104 DMS 6410 MICROPHONE CONSOLE TOP VIEW Microphone with red light ring Internal loudspeaker LED Colours red green yellow red and green It depends on the console setting chairman delegate interpreter 2 buttons 1 short and 1 long with different functions depending on the console setting chairman delegate interpreter 6 2 small buttons to adjust the internal loud speaker volume LATERAL PANELS There are 2 1 on the left side 1 on the right side 3 5
100. questo esce dall alimentatore 2 3 INFORMAZIONI SULLE BATTERIE Utilizzare sempre batterie ricaricabili del tipo indicato nel presente manuale Verificare che sia rispettata la polarit delle batterie Non cortocircuitare le batterie ad esempio collegando i 2 poli opposti con un filo di metallo e Smaltire le batterie esaurite negli appositi contenitori facendo riferimento alle norme di legge vigenti nel paese di utilizzo in materia di ecologia e protezione dell ambiente 3 Impedire che oggetti o liquidi entrino all interno del prodotto perch potrebbero causare un corto circuito L apparecchio non deve essere esposto a stillicidio o a spruzzi d acqua nessun oggetto pieno di liquido quali vasi deve essere posto sull apparecchio 4 Non eseguire sul prodotto interventi modifiche riparazioni se non quelle espressamente descritte sul manuale istruzioni Contattare centri di assistenza autorizzati o personale altamente qualificato quando e l apparecchio non funziona o funziona in modo anomalo ilcavo di alimentazione ha subito gravi danni oggetti o liquidi sono entrati nell apparecchio e l apparecchio ha subito forti urti 5 Qualora questo prodotto non sia utilizzato per lunghi periodi togliere la tensione dal cavo di alimentazione o scollegare l alimentatore esterno 6 Nel caso che dal prodotto provengano odori anomali o fumo spegnerlo immediatamente e togliere la tensione dal cavo di alimentazione o scol
101. rafen die den verschiedenen Funktionsmodalitaten der Sprechstelle DMS 6410 inh rent sind MIKROFONRING Der Ring ist mit einem roten Leuchtring angeschlossen der die Mikrofonaktivierung angibt FUNKTION DER DMS 6410 SPRECHSTELLE WENN ALS VORSITZENDER EINGESTELLT Der Vorsitzende ist nicht Gegenstand einer eventuellen Eingrenzung Anzahl gleichzeitig angeschal teter Mikrofone Die Anschaltung des Mikrofons ist auch m glich wenn ein anderer Vorsitzender die Vorrangfunktion i nutzt und die Sprechstellen der Abgeordneten ausschaltet Es ist nicht m glich das Mikrofon anzuschalten wenn die zentrale Einheit die Sprechstelle nicht ange nommen hat oder wenn alle Vorsitzenden und Abgeordnetensprechstellen durch den Parameter MIC MODE SET UP der zentralen Einheit deaktiviert sind Grosse Taste A NORMALE Funktion aktiviert das Mikrofon der Sprechstelle das rote Led und der Leuchtring des Mikrofons gehen an Die Aktivierung des Mikrofons ist kurzzeitig wenn die Taste ge dr ckt gehalten wird oder lang anhaltend wenn die Taste einmal kurz gedr ckt wird Wenn die Taste losgelassen wird oder erneut f r einen kurzen Moment gedr ckt wird im Fall einer lang anhaltenden Einschaltung deaktiviert sich das Mikrofon das rote LED und der rote Leuchtring des Mikrofons gehen an Durch kurzes Dr cken der Taste A schaltet sich das Mikrofon f r einen l ngeren Zeitraum an Es ist den i noch m gl
102. red LED will flash for 3 secon ds b If the booking is accepted up to 10 delegates RESERVATION NEXT parameter NEXT n NEXT the green LED will lit note another button press will cancel the booking The red LED flashes for 3 seconds also when the max number of bookings has already been reached If the microphone has already been activated in toggle mode it is still possible to change to the push to talk mode by pressing and holding the A button B short button MUTE it momentary mutes the microphone if this has been previously opened by using the A long button in toggle mode and the red LED starts flashing Another press cancels the MUTE state the microphone is open and the red LED is lit without flashing again During its MUTE state the delegate console is anyway counted and added to the sum of all open microphones that is significant only if the max number of open microphone limitation has been set The delegate console can be turned off by pressing the A long button also when the microphone is muted When a chairman gets the PRIORITY all activated delegate consoles will be momentary muted and their red LEDs will start flashing When the PRIORITY state ends all microphones of previou sly activated delegate consoles will be on again When a chairman uses the RESET function all activated or booked delegate consoles will be forced off 45 Lil Lil Lil Lil e The flashing yellow red
103. revent the risk of electric shock never open the product there are no parts inside that the user needs to access 2 2 POWER SUPPLY BY MEANS OF AN EXTERNAL ADAPTER a Use the dedicated adapter only verify the mains voltage corresponds to the voltage shown on the adapter rating plate and the adapter output voltage value and type direct alternating corresponds to the product input voltage if not please contact your RCF dealer verify also that the adapter hasn t been damaged due to possible clashes hits or overloads b The mains voltage which the adapter is connected to is sufficiently high to involve a risk of electrocution pay attention during the connection i e never do it with wet hands and never open the adapter Make sure that the adapter cable is not or cannot be stepped on or crushed by other objects pay particular attention to the cable part near the plug and the point where it leads out from the adapter 2 3 INFORMATION ABOUT BATTERIES Use always rechargeable batteries as indicated on present manual Verify the batteries polarity is correct e Do NOT short circuit batteries i e by connecting the 2 poles together with a metallic wire Throw empty batteries into dedicated garbage can according to the present laws of your country about ecology and environment protection 3 Make sure that no objects or liquids can get into this product as this may cause a short circuit This apparatus shall not b
104. rima di collegare ed utilizzare questo prodotto leggere attentamente le istruzioni contenute in questo manuale il quale da conservare per riferimenti futuri Il presente manuale costituisce parte integrante del prodotto e deve accompagnare quest ultimo anche nei passaggi di propriet per permettere al nuovo proprietario di conoscere le modalit d installazione e d utilizzo e le avvertenze per la sicurezza L installazione e l utilizzo errati del prodotto esimono la RCF S p A da ogni responsabilit ATTENZIONE per prevenire i rischi di fiamme o scosse elettriche non esporre mai questo prodotto alla pioggia o all umidit salvo il caso in cui sia stato espressamente progettato e costruito per l uso all aperto AVVERTENZE PER LA SICUREZZA 1 Tutte le avvertenze in particolare quelle relative alla sicurezza devono essere lette con particolare attenzione in quanto contengono importanti informazioni 2 1 ALIMENTAZIONE DIRETTA DA RETE La tensione di alimentazione dell apparecchio ha un valore sufficientemente alto da costituire un rischio di folgorazione per le persone non procedere mai all installazione o connessione dell apparecchio con l alimentazione inserita Prima di alimentare questo prodotto assicurarsi che tutte le connessioni siano corrette e che la tensione della vostra rete di alimentazione corrisponda quella di targa dell apparecchio in caso contrario rivolgetevi ad un rivenditore RCF Le parti metalliche
105. rings are lit while the following consoles would not be found by the DMU 6100 central unit e When an interpreter console is connected make sure that the relevant INTERPRETER LINE TER MINATION DIP switch of the DMU 6100 central unit is set to OFF interpreter console available Note the interpreter console LINE TERMINATION switch has no effect e f an interpreter console is not connected to dedicated central unit port it will be necessary to set the relevant INTERPRETER LINE TERMINATION DIP switch of the DMU 6100 central unit to ON JACK OUTPUTS On DMS 6410 console lateral panels there are 2 jack outputs 3 5 mm 1 8 an output on both sides Their output signal depends on the system configuration and the console operating mode delegate chairman interpreter The jack outputs can be configured by means of the CONSOLE OUT JACK parameter SET menu e HEADPHONES The jack output audio signal is optimized for headphones If headphones are used the console internal loudspeaker turns off and the volume can be adjusted by using the relevant 2 small buttons from 0 to the maximum value set on the DMU 6100 central unit e RECORDING The jack output audio signal is optimized for recording the console internal loud speaker does not turn off when a jack output is used The volume control is enabled and the level can be adjusted between about 3096 and 10096 but it cannot be set to 0 The DMU 6100 central unit volume setting h
106. rman LC Display angezeigt error delegate error Nachdem evtl Probleme behoben wurden ist es n tig die Initialisierung zu wiederholen schalten Sie das Ger t aus und wieder ein oder ftir 3 Sekunden die Taste SET gedruckt halten und anschlieBend die Taste ENTER dr cken Nach erfolgreicher Initialisierung erscheint im Display wo x y und zzz sind jeweils die Anzahl der Pr siden ten 0 3 die Anzahl der Dolmetscher 0 2 die Anzahl der Delegierten 0 60 oder 0 180 je nach Konfiguration Nach der Anerkennung bleiben die Leuchtringe der Sprechstellen 2 Sekunden Delegiert und Dolmetscher oder 4 Sekunden Pr sident an Dadurch l sst sich berpr fen welche und wie viele Sprechstellen der Delegierten Dolmetscher oder Pr sidenten eingestellt wurden Zu diesem Zeitpunkt erscheint auf dem Display die ein gestellte Funktion FREE DISCUSSION i Die Ausf hrungsarten werden in den Beschreibung smen s MODE besprochen In diesem Anfangsmen Default ver ndert man die Lautsprecherstarke des Monitors der Zentrale wenn die Ta sten A und Y gedr ckt werden Im Display zeigt die Leiste das aktuelle Niveau an max 16 Default 10 Mute O Durch die Taste MODE gelangt man ins Einstellung smen der Modalit ten IMPORTANT Wichtig Die Ver nderung aller MODE Einstellungen kann w hrend der Diskus sion gestartet werden Die neuen Einstellungen sind gegen ber dem System nicht retr
107. s PLAY Lautst rker des Eingangs f r Telekonferenz 62 Durch Dr cken der Taste OUT VOLUME gelangt man ins Einstellungsmen der Ausgangslautst r ken durch wiederholtes Drucken hat man die folgenden Parameter in Rotation Verwenden Sie die Tasten A und Y um eine Anderung herbeizuf hren maximales Niveau 16 voreingestelltes Niveau 10 Niveau 0 Interne Lautsprecherlautstarke der Sprechstellen Lautstarke des Hauptaudioausgangs MAIN OUT ERROR MELDUNGEN Durch Dr cken der Taste ENTER gelangt man aus der Fehlerdarstellung i W hrend der Adressierung CHRM INIT ERROR Es gibt mehr als drei Vorsitzendensprechstellen im System DEL INIT ERROR Es gibt mehr als 30 Sprechstellen in einer Leitung eA N B Wenn in der zentralen Einheit DMU 6100 die Anschl sse der Abgeordneten Vorsitzenden und Dolmetscherleitungen eingef gt werden ist das NON System f hig es hervorzuheben De shalb wird keine Signalisierung auf dem LCD Display angezeigt W hrend des Betriebs CONSOLE ERROR Eine Vorsitzenden oder Abgeordne tensprechstelle funktioniert nicht mehr z B Leitung 2 SSES CONSOLE ERROR Eine Dolmetschsprechstelle funktio niert nicht mehr z B Dolmetscher Nr 2 Position 1 ist die erste Sprechstelle einer direkt an die Zentrale DMU 6100 angeschlossenen Lei i tung Position 30 ist die letzte Sprechstelle einer Leitung Fur den Fall dass es mehr Schaden gibt zeig
108. schaltet Das LED und der Leuchtring werden ebenfalls ausgeschaltet die war tenden Abgeordneten mit der Voranmeldung werden deaktiviert das gr ne LED schaltet sich aus 69 EJ J HO S 1 13Ga e Das gelbe LED rot gr n blinkt auf e w hrend der Simultan bersetzung gibt es die Aufforderung des Dolmetschers wieder langsamer zu sprechen e w hrend der nachgeordneten bersetzung gibt es die Aktivierung der Dolmetschsprechstelle wieder und aus diesem Grund ist das Mikrofon des Abgeordneten vor bergehend deaktiviert Das gelb blinkende LED erscheint nur in den Abgeordnetensprechstellen mit aktivem Mikrofon oder solchen die auf MUTE eingestellt sind In den nicht aktiven oder denen die vorangemeldet werden mit gr nem LED wenn angeschaltet geschieht nichts FUNKTION MIC AUTO OFF NUR ABGEORDNETE Bei Einschaltung der Funktion MIC AUTO OFF in der Konfigurierung der Zentrale wird nach 30 fortlaufenden Sekunden mit aktivem Mikrofon in denen die Stimme des Abgeordneten nicht wie dergegeben wird das entsprechende Mikrofon automatisch ausgeschaltet Jedes Mal wo der Ab geordnete in den letzten 5 Sekunden die ihm bleiben zu sprechen beginnt werden dar ber hinaus 10 Sekunden zur Verf gung gestellt bevor das Mikrofon deaktiviert wird Wenn das Mikrofon des Abgeordneten vor bergehend deaktiviert wird Funktion MUTE die vom Vorsitzenden oder vom selben Abgeordneten eingegeben wird ist die Funktion MIC AU
109. scite JACK Potenza max modo Headphones Livello d uscita modo Recording Risposta in frequenza 3 dB nominale 7 dBu THD 0 196 max 10 dBu THD 0 5 35 Hz 20 kHz 100 Q gt 85 dBA MIC LINE A MIC LIN B TELECONF IN FROM le console nominale 0 dBu max 10 dBu soglia del limiter delle console 100 Hz 15 kHz 100 0 gt 60 dBA una sola console attivata Tutte le console delegati presidenti di ciascuna linea nominale 7 dBu max 10 dBu THD 0 596 25 Hz 25 kHz 100 O gt 85 dBA Tutti le console interpreti oppure tutti gli altri ingressi 1 W su un altoparlante con Z 4 THD 1 2 V RMS su 16 O 100 Hz 15 kHz gt 80 dBA Tutti le console interpreti oppure tutti gli altri ingressi ponendo in cortocircuito i 2 poli tramite un contatto R lt 500 O 48 V dc 9mA 20 50 suggerito 22 tipo B 5V dc 5 28 V dc 1A 48 V dc 1 5 A in ciascuna linea con 30 console elettrete cardioide 200 Hz 12 kHz gt 60 dBA all uscita MAIN OUT fino a 32dB sopra il livello massimo 20 dB 48 V dc nominale lt 20 mA max 50 mA altoparlante int volume max 1 W THD lt 1 200 mm 135 mm 60 mm 1 09 kg 450 mm speciale 10 poli con connettori RJ lungo 2 5 m 60 mW su 16 0 596 THD nominale 4 dBu 0 296 THD max 5 dBu 170 Hz 16 kHz IMPORTANT NOTES Before connecting and using this product please read this in
110. se Zeiten k nnen verzehnfacht werden 20 Sekunden f r Abgeordnete und Dolmetscher 40 Sekunden f r die Vor sitzenden durch Gedr ckt halten der Taste SET f r 3 Sekunden wenn die Zentrale DMU 6100 angeschaltet wird oder bei Neustart des Systems durch Dr cken der Taste ENTER im Men SET 71 Li HO S 1 13Ga NICHT BETRIEBSBEREITE SPRECHSTELLE IN BY PASS F r den Fall dass eine Sprechstelle nicht richtig funktioniert ist es immer ratsam sie von der Lei tung zu trennen falls dies nicht sofort m glich ist z B wenn die Entfernung zwischen einer Spre chstelle und einer anderen und die Kabell nge festgelegt ist die besch digte Sprechstelle kann deaktiviert werden auch wenn sie an die Leitung angeschlossen wird indem sie zul sst dass die Signale Audio und Daten zu den andern Sprechstellen weitergeleitet werden Einstellung der Mikroschaltungen f r die Deaktivierung der Sprechstelle Nicht betriebsbereite Sprechstelle in by pass 1 ON 2 OFF By pass Das System muss neugestartet werden um die neue Einstellung in betriebsbereitschaft zu versetzen SPEZIALKABEL AN 10 POLE F R SPRECHSTELLEN ANSCHLUSS RJ an 10 Pole 1 ROT 2 SCHWARZ 3 GRAU 4 BLAU 5 ORANGE 6 WEISS 7 BILDSCHIRM 8 GELB 9 BRAUN 10 GR N pin pin 1 48V Strom c c 6 Signal Audio R ckkehr 2 Massenstrom 7 digitale Masse 3 bermittlung und Empf
111. segnale in uscita ottimizzato per l uso delle cuffie inserendole si disattiva l alto parlante interno ed il volume pu essere regolato con i relativi tasti tra O e il massimo valore impo stato sull unit centrale DMU 6100 RECORDING II segnale in uscita ottimizzato per l uso di un registratore e inserendo uno qualun que dei 2 jack l altoparlante non disattivato Il controllo del volume viene comunque abilitato e pu essere impostato tra circa il 30 ed il 100 ma non pu essere portato a zero l impostazione del volume sull unit centrale DMU 6100 non ha effetto e DISABLED Non presente alcun segnale sulle uscite jack solo per presidenti e delegati L altopar lante interno comunque funzionante Se previsto l utilizzo della traduzione simultanea mantenere il parametro CONSOLE OUT JACK su HEADPHONES altrimenti non sar possibile ascoltare la lingua tradotta tramite cuffie Nelle console interpreti le prese jack sono sempre in modalit HEADPHONES uso cuffia a prescin dere dall impostazione del parametro CONSOLE OUT JACK dell unit centrale DMU 6100 impo stazione che ha effetto soltanto per le console presidenti e delegati pertanto il volume sempre regolabile tra zero ed il massimo livello impostato sull unit centrale PANNELLO SUPERIORE Sono presenti 2 tasti volume 2 tasti di selezione ed un LED bicolore che hanno una funzionalit dipendente dalla modalit operativa delegato
112. struction manual carefully and keep it on hand for future reference The manual is to be considered an integral part of this product and must accompany it when it changes ownership as a reference for correct installation and use as well as for the safety precautions RCF S p A will not assume any responsibility for the incorrect installation and or use of this product WARNING to prevent the risk of fire or electric shock never expose this product to rain or humidity except in case it has been expressly designed and made for outdoor use SAFETY PRECAUTIONS 1 All the precautions in particular the safety ones must be read with special attention as they provide important information 2 1 POWER SUPPLY FROM MAINS direct connection a The mains voltage is sufficiently high to involve a risk of electrocution therefore never install or connect this product with the power supply switched on b Before powering up make sure that all the connections have been made correctly and the voltage of your mains corresponds to the voltage shown on the rating plate on the unit if not please contact your RCF dealer The metallic parts of the unit are earthed by means of the power cable An apparatus with CLASS I construction shall be connected to a mains socket outlet with a protective earthing connection d Protect the power cable from damage make sure it is positioned in a way that it cannot be stepped on or crushed by objects e To p
113. t der Display LCD nur einen einzigen Fehler auf einmal an sobald das Ger t eingeschaltet ist Deswegen muss der Ausl ser des ersten Fehlers beseitigt i werden um die Darstellung des folgenden Fehlers zu erhalten falls eingetroffen nachdem das System erneut besch digt wurde f r den Fall dass es wahrend der Lesung des EEPROM Probleme gibt interner Speicher Ineinem solchen Fall werden immer die ersten Parameter wiederhergestellt und die technische Wartung wird n tig Stromsch den und Schmelzsicherungen die technische Wartung ist n tig Diese Message k nnte nach Einschalten des Systems rr und des Aufzeigens der Sprechstellenanzahl auftauchen Interner Stromschaden 12 V o 3 Schaden interner Strom 24 V Schaden externer Strom 24 V DPS 6202 Schaden der Schmelzsicherungsleitungen der Sprechstellen 1 und 2 Schaden der Schmelzsicherungsleitungen der Sprechstellen 3 und 4 DEC 6104 Schaden der Schmelzsicherungsleitungen der Sprechstellen 5 und 6 DEC 6104 MIKROFONSPRECHSTELLE DMS 6410 OBERES PANEEL Mikrofon mit Leuchtring Interner Lautsprecher Zweifarb LED der die Farben rot gr n gelb rot mehr gr n visualisiert je nach Einstel lung der Sprechstelle Vorsitzender Abge ordneter Dolmetscher 2 Kleine und groBe Taste deren Funktion von der Sprechstelleneinstellung abh ngt Vorsit zender Abgeordneter Dolmetscher Tasten f r die Lautst rkenregulierung des in
114. ta anche per forzare il riavvio del sistema per esempio dopo aver aggiunto una console 3 Presa jack 6 3 mm 1 4 per cuffie escludente l altoparlante monitor interno 9 Altoparlante monitor interno che diffonde il segnale presente all uscita audio MAIN OUT PANNELLO POSTERIORE DMU 6100 15 Ingresso audio mic linea A con presa XLR 16 GAIN Regolazione del guadagno dell ingresso A 17 CMD IN Comando abilitazione mute dell ingresso A Nota la scelta tra abilitazione o mute dipende aall impostazione del parametro VOX CMD INPUT A Microinterruttori per la configurazione dell ingresso A e PHANTOM Alimentazione Phantom inserita OFF Phantom disinserita e MIC LINE MIC Ingresso microfonico LINE Ingresso per sorgenti ad alto livello es CD e HIGH PASS ON Filtro passa alto inserito OFF Filtro disinserito 19 Microinterruttori per la configurazione dell ingresso B come sopra per l ingresso 20 CMD IN Comando abilitazione mute dell ingresso B Nota la scelta tra abilitazione o mute dipende dall impostazione del parametro VOX CMD INPUT B 21 GAIN Regolazione del guadagno dell ingresso 22 Ingresso audio mic linea B con presa XLR PA TELE e QUO WER LIME LEVEL MAIN DUT ema 718 1 OUT E unita IR Su vasi e 1 Ge e 63 Uscite audio BQO separate connettore RCA
115. tato PLAY REC In modalit PLAY l uscita audio per la registrazione SYSTEM disabilitata in modalit REC l ingresso audio PLAY disabilitato Tasto SET per la selezione parametri nel men di configurazione al quale si accede mantenen do premuto il tasto SET per almeno 3 secondi Display LCD retroilluminato Tasto IN VOLUME per l impostazione dei volumi degli ingressi Tasto OUT VOLUME per l impostazione dei volumi delle uscite Tasto MODE per l accesso e la selezione dei parametri nel men d impostazione della modalit 47 Tasti eg men iniziale di default che visualizza il modo permettono di aumentare diminuire il volume dell altoparlante monitor interno vedi punto 14 se invece si selezionato un men tramite i tasti SET MODE IN VOLUME e OUT VOLUME cambiano il valore del para metro selezionato 2 IItasto ENTER si utilizza confermare salvare le impostazioni effettuate Se lo si e si aspetta il ritorno alla schermata iniziale di default l effetto differente a seconda del menu selezionato nessun salvataggio per i menu SET e MODE per i ment di controllo del volume i parametri sono comunque salvati La pressione del tasto ENTER nel men SET comporta anche la reinizializzazione del siste ma con la conseguente eventuale interruzione della discussione in corso Questa procedura pressione del tasto SET per 3 secondi pi successivo ENTER pu essere utilizza
116. ten AnschlieBend dr ckt man die Taste SET um die folgenden Parameter zu visu alisieren in Rotation NTERPRETATION e A amp B INPUT MODE e VOX CMD INPUT A e VOX CMD INPUT B e CHIME ON CHAIRM e CONSOLE OUT JACK Nutzen Sie die Tasten und Y um auszuw hlen zu ndern Nachdem die Parameter ge ndert wurden dr cken Sie zur Best tigung ENTER und gehen Sie aus dem Men raus Nach Dr cken von ENTER wird das System neu initiiert und die Diskussion unterbrochen um die Neueinstellungen zu best tigen INTERPRETATION Einstellung der bersetzungsart sequentiell simultan deaktiviert Die Sequenz bersetzung wird aktiviert wenn eine der zwei bersetzungssprechstellen um Aktivierung bittet durch Deaktivierung der anderen die bersetzte Spra che der Dolmetscher wird den 3 Audioausg ngen des Systems zugeschickt Sprechstellenleitung MAIN OUT und der Ausgang f r Telekonferenz Wenn der Dol metscher das eigene Mikrofon deaktiviert wird auf die 3 Audiosystemausg nge das gemischte Signal der Spre chstellen verschickt IN A IN B IN PLAY und die Klingel Chime Aktivierte Simultan bersetzung Wenn eine der zwei ber setzungssprechstellen die Aktivierung erbittet die ande wird deaktiviert ist die bersetzte Sprache nur auf den zwei Kopfh rerausg ngen Jack der Sprechstellen ver f gbar die internen Kopfh rer der Sprechstellen sind de aktiviert Den 2 anderen Systemausgangen MAIN
117. then it would not be possible to turn it on again as long as the technical problem is still present DMS 6410 MICROPHONE CONSOLE SET TO DELEGATE Every delegate is affected by the limitation of the max number of open microphones from 1 to 6 if this function has been set in the MIC MODE SET UP parameter of the MODE menu If this limit is reached it will not be possible to activate a further delegate console If the MIC MODE SET UP parameter is set to 1 MIC ACT O RIDE only 1 microphone will be open at a time and also overridden by the next delegate who turns its console on The console cannot be activated and its microphone cannot be open if e A chairman is resetting all consoles RESET e A chairman has got the PRIORITY The central unit has not recognized that console All delegate consoles have been disabled by setting the central unit MIC MODE SET UP para meter e Along button the microphone gets open the red LED and the light ring get lit The microphone activation is either momentary when the button is pressed and hold push to talk mode or stable if the button is pressed once for an instant toggle mode When released in push to talk mode or pressed again in toggle mode the red LED the microphone and its light ring turn off If the max number of open microphones is reached any attempt to turn the console on will cause 8 If there is no booking RESERVATION NEXT parameter OFF the
118. tion command a dry closing contact The chime can be also activated if the parameter CHIME ON CHAIRM is set to ACTIVE when a chairman turns the priority function on 69 SPEAK SLOWLY Internal dry closing contact max 28 V dc 1 A to signal the SPEAK SLOWLY command SPEAK SLOWLY is indicated by the flashing yellow LED on consoles when the relevant interpreter console button is pressed 35 LINE 1 First console line made of max 30 consoles port INTERPR I First interpreter console port LINE 2 Second console line made of max 30 consoles port INTERPR II Second interpreter console port INTERPR LINE TERMIN DIP switches and Il to enable the INTERPR I and INTERPR II ports SIE Wen V interpreter console available interpreter console available 40 Mains connector 100 240 V ac with fuse 41 Earth terminal 42 Room for the optional board DEC 6104 33 DMU 6100 SOFTWARE MENUS After turning the device on the LCD displays the writing LI The firmware release is shown i e 1 0 Then the system starts recognizing all console types delegate chairman interpreter during this time every console red light ring is lit Each interpreter console is to be directly connected to a dedicated input and cannot be added to the lines L1 L2 If there are more than 3 chairmen chairman error or more than 30 consoles in each line dele gate error the system reboot will be stopp
119. ure oder spezialisierte Firmen erfolgen darf damit die Aufstellung korrekt und nach den hierf r vorgesehenen Regelungen verl uft Das ganze Audiosystem muss mit den Normen und den herrschenden gesetzlichen Regelungen konform sein die das elektrische System betreffen 9 Befestigung und F rderwagen Falls vorgesehen wird das Produkt durch F rderwagen oder Befestigungen genutzt die vom Hersteller empfohlen sind Die Zusammensetzung Ger t Halterung muss mit gr Bter Sorgfalt bewegt werden Unvorhergesehenes Stoppen exzessive Sch be und unregelmaBige oder geneigte Fl chen k nnen einen Sturz des Gebildes bewirken 10 Es gibt unz hlige mechanische und elektrische Faktoren zu beachten wenn ein professionelles Audiosystem installiert wird auBer den aktustischen wie der Schalldruck die Abdeckungswinkel der bertragungsbereich 11 Geh rverlust Ist man einer zu hohen Lautst rke ausgesetzt kann dies zu Geh rverlust f hren Das Schalldruckniveau welches f r das Geh r sch dlich sein kann variiert von Person zu Person und hangt von der Dauer ab Um eine gef hrliche Situation abzuwenden in der man einem hohen Schalldruckniveau ausgeliefert ist ist es notwendig dass wer auch immer diesem Schalldruck ausgeliefert ist die angemessenen SchutzmaBnahmen ergreift Im Fall der Anwendung eines Wandlers um einen hohen Schalldruck zu erzeugen ist es n tig Ohrenst psel oder Kopfh rer anzuziehen Wichtige Hinweise Um das von Kab
Download Pdf Manuals
Related Search
Related Contents
バリアリールLongスタンドタイプ バリアリールLong RCA 26930 User's Manual Istruzioni di montaggio e d`uso SC_500 - Thermo|solar EC400 (Español) Warm-R (Pitched Roof) BBA Cert PDF Infovox iVox – User Manual MODE D`EMPLOI - Massif du Sancy Coby TFTV2625 LCD TV Nokia Lumia 635 (T-Mobile) User Guide USER` MANUAL Copyright © All rights reserved.