1. 2015 7 13 19 21 39 USING PARTS Safety precautions Before using your new air conditioner please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance Because the following operating instructions cover various models the characteristics of your air conditioner may differ slightly from those described in this manual If you have any questions call your nearest contact center or find help and information online at www samsung com HSITDNA Important safety symbols and precautions A WARNING Hazards or unsafe practices that may result in severe personal injury or death A CAUTION Hazards or unsafe practices that may result in minor personal injury or property damage ae Unplug the power plug from the O Follow directions salle her O Do NOT attempt Do NOT disassemble Make sure the machine is grounded to prevent electric shock FOR INSTALLATION WARNING Q Plug the power cord into a wall socket with the power specifications of the product or higher and use the socket for this appliance only In addition do not use an extension cord gt Sharing a wall socket with other appliances using a power strip or extending the power cord may result in electric shock or fire gt Do not use an electric transformer It may result in electric shock or fire gt Ifthe voltage frequ
2. the refrigerant cylinder to the equipment follow the instructions below 2 1 Before recharging check whether the cylinder has a siphon or not There are two ways to recharge the refrigerant Cylinder with siphon Cylinder without siphon siphon gt Charge the refrigerant standing the gt Charge the refrigerant turning the cylinder cylinder upright upside down IfR410A refrigerant is charged with gas the composition of the charged refrigerant changes and the Note Characteristics of the equipment vary During the measuring operation of refrigerant quantity added use an electronic balance If cylinder doesn t have syphon upset it 37 Panama ASV12P IBIM DB68 03248A EN 2 indd 37 2015 7 13 19 21 51 Make sure to check for gas leaks before completing the installation process connecting the assembly pipe and hose between indoor unit and outdoor unit insulating the cables hose and pipe and fixing the indoor unit to the installation plate Test part for outdoor unit Charging Test part for indoor unit Tightening torque for body cap Refer to the table gt Before inspecting the leakage use a torque wrench to close the cap for the service valve Comply with a tightening torque for each size of the diameter and TI tighten the cap firmly to prevent any leakage gt To check for any possible leakage insert inert gas into the pipes connected to indoor outdoor units and
3. y Spindle es DANG check the connection part of the indoor outdoor units with soap lather or liquid for leakage test core Tightening torque Outer Diam eter mm Body cap Nem ern port cap R 22 Diameter of the screw 7 16 20UNF Nem R 410A Diameter of the screw 1 2 20UNF 06 35 20 25 09 52 20 25 Tightenina t di R 612 70 25 30 ightening torque for charging port cap Refer to the table 015 88 30 35 919 05 35 40 To check for gas leaks on the outdoor unit 1 Nem 10 kgf cm Check the valve A and B using a leak detector To check for gas leaks on the indoor unit Check the flare nut C and D using a leak detector 38 Leak test with nitrogen before opening valves In order to detect basic refrigerant leaks before recreating the vacuum and recirculating the R410A it s responsible of installer to pressurize the whole system with nitrogen using a cylinder with pressure reducer at a pressure above 40 bar gauge Leak test with R410A after opening valves Before opening valves discharge all the nitrogen from the system and create vacuum according to page 35 37 After opening valves check leaks using a leak detector for refrigerant Pump down before disconnecting the refrigerant connections for unit repair removal or disposal Pump down is an operation intended to collect all the system ref
4. When the walls are blocking front and the rear side of the outdoor When the upper part of the outdoor unit and units the air outlet is opposite the wall a Fo 85 SE LUCE I Na Y kuma 600 or more a a gt When front and rear side of the outdoor unit is towards the wall UP eL dJ kha Jk Jk 1500 or 600 or 3000 or 3000 or 200 or more more more more more 300 or more 10r More 500 or more 1500 or more HSITDNA 300 or more E 101 More 500 or more Ifinstallation is done in inappropriate space unit may generate sound and cause bad effect on the product caution Installation must be done in level and in a place where vibration will not cause any effect Accessories The following accessories are supplied with the air conditioner B The number of each accessory is indicated in parentheses NOTE I Accessories in the indoor unit case Installation Plate 1 Remote Batteries for User s amp Installation controller 1 Remote controller 2 Manual 1 amp Z I Accessories in the outdoor unit case 4 wire 3 wire 2 wire Assembly Cable 1 Assembly Cable 2 Assembly Cable 1 Rubber Leg 4 XX09 12KX XX18 24KkX 9K 18 242 5 B 85 x I The flare nuts are attached to the end of each pipe of an evaporator or a service port Note Use the nuts when connecting the pipes The d
5. Panama ASV12P IBIM DB68 03248A EN 2 indd 1 2015 7 13 19 21 39 MESSE Features of your new air conditioner Contents I Cool Summer Offer USING PARIS On those hot sweltering summer days and long restless nights there is no better escape from the heat than the cool comforts of home Your new air conditioner brings an end to exhausting hot summer days and lets you rest Beat the heat with your own air conditioner this summer I Cost Efficient System Your new air conditioner not only provides maximum cooling power in the summer but also can be an efficient heating method in the winter with the advanced Heat pump system Heat pump system is 3 times more efficient compare to the other electrical heating appliance so you can further reduce its running cost Now meet year round needs with one air conditioner Look for Everywhere The elegant and harmonious design gives priority to the esthetics of your space and complements any of your existing interior decor With its soft color and rounded edge shape the new air conditioner adds class to any room Enjoy what your air conditioner offers both functionally and esthetically good sleep function good sleep function allows you to set a comfortable sleep temperature while saving energy and having sound sleep I Virus Doctor function Virus Doctor function generates hydrogen H and oxygen O to attack undesirable air contaminants such as bact
6. attached to the window frame 2 Fix the plate hanger on two studs I 2 Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit 3 Attach the installation plate to the wooden upright using tapping screws Search for other spots if there are less than two studs or the distance between the studs are different from the A plate hanger CAUTION Fix the installation plate without inclining to one side e Make sure that a wall can withstand the weight of the product If you install the product in a place where it is not strong enough to withstand the product weight the unit could fall and cause injury WARNING Connecting the assembly cable I Cable specification Model Power cable Interconnection cable Type GL 3G 1 5mm HO7RN F X 09 12PXX SITAWG16 AG 1 5mm HO7RN F 20A 3G 1 0mm HO7RN F 2 i XX18 24PXX 3G 2 5mm HO7RN F 2 0 75mm HOSRN F 25A Connect the power cable to the auxiliary circuit breaker If every pole fails to connect to nore the power supply it must be incorporated in a wire with a contact opening of 23mm I Connecting the cable Electrical work 1 For electrical and earth works comply with the technical standards of electrical installations and the the wiring regulations of the Electricity Enterprises Act 3 Precautions when connecting terminal blocks of the indoor unit gt Before connecting make sure t
7. 430 612 70 mm 500 620 Indoor outlet pipe Connecting pipe 915 88 mm 690 830 Excessive torque can be cause of gas leakage In case brazing the pipe the nitrogen gas must be blown into the NOTE pipe 50 Pa The joint must be accessible and serviceable 7 For further details on how to connect to the outdoor unit and purge the air refer to page 35 36 Tighten the flare nut with torque wrench according to specified method comen lf the flare nut is over tightened the flare may break and cause refrigerant gas leakage Installing and connecting the drain hose of the indoor unit When installing the drain hose for the indoor unit check if condensation draining is adequate When passing the drain hose through the 65 mm hole drilled in the wall check the followings The drain hose must NOT The end of the drain hose must NOT slant upwards be placed under water LE 0 0 0 15cm tess z Ditch The drain hose must not Keep a clearance of at least Do not place the end of the be bent 5cm between the end of the drain hose in a hollow drain hose and the ground 33 Panama ASV12P IBIM DB68 03248A EN 2 indd 33 2015 7 13 19 21 49 Installing and connecting the drain hose of the indoor unit Drain hose installation 1 If necessary connect the 2 meter extension drain hose to the drain hose 2 Ifyou use the extension drain hose insula
8. Spanish www samsung com latin_en support Engli ti www samsung com latin support Spanish ti ti EL SALVADOR 800 6225 800 0726 7864 www samsung com latin support Spanish www samsung com latin en support Engli GUATEMALA 1 800 299 0013 1 800 299 0033 www samsung con latin support Spanish HONDURAS 800 2791 9267 800 2791 9111 www samsung com atin_en support Engli l www samsung com latin support Spanish www samsung com latin en support Engli JAMAICA 1 800 234 7267 1 800 SAMSUNG 726 7864 www samsung com latin_en support Engli NICARAGUA 001 800 5077267 www samsung com www samsung con in support Spanish in en support Engli o PANAMA 800 7267 800 0101 jav www samsung com www samsung com in support Spanish in en support Engli 2 PUERTO RICO 1 800 682 3180 jav www samsung com www samsung com in support Spanish in en support Engli TRINIDAD amp TOBAGO 1 800 SAMSUNG 726 7864 SF www samsung conVlatin support Spanish www samsung com latin_en support Engli Q VENEZUELA 0 800 SAMSUNG 726 7864 www samsung com ve support COLOMBIA Bogota 600 12 72 Gratis desde cualquier parte del pais 01 8000 1121120 desde su celular SAM 726 www samsung com co suppor CHILE 800 SAMSUNG 726 7864 HHP 02 24828200 www samsung com cl support B
9. The air conditioner is compliant with the requirements of the Low Voltage Directive 72 23 EEC the EMC Directive 89 336 EEC and the Directive on pressurized equipment 97 23 EEC The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and requirements set forth in the Operating limits table included in the manual shall immediately invalidate the warranty The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry Do not use the units if damaged If problems occur switch the unit off and disconnect it from the power supply In order to prevent electric shocks fires or injuries always stop the unit disable the protection switch and contact SAMSUNG technical support if the unit produces smoke if the power cable is hot or damaged or if the unit is very noisy Always remember to inspect the unit electric connections refrigerant tubes and protections regularly These operations should be performed by qualified personnel only The unit contains moving parts which should always be kept out of the reach of children Do not attempt to repair move alter or reinstall the unit If performed by unauthorized personnel these operations may cause electric shocks or fires Do not place containers with liquids or other objects on the unit All the materials
10. airflow blades work properly 4 Press the Power button to stop the operation When you complete the installation successfully hand over this manual to the user for storage in a handy and safe NOTE place Pump down procedure when removing the product 1 Turn on the air conditioner and select Cool mode to run the compressor for 3 minutes 2 Release the valve caps on High and Low pressure side 3 UseL wrench to close the valve on the high pressure side 4 Approximately 2 minutes after close the valve on the low pressure side 5 Stop operation of the air conditioner 6 Disconnect the pipes 40 Panama ASV12P IBIM DB68 03248A EN 2 indd 40 2015 7 13 19 21 51 Items to prepare compressor and insulation tape should be prepared by an installation technician How to connect your extended power cables Tools Crimping plier Connection sleeve mm Insulation tape Contraction tube mm Spec MH 14 20x 7 0 HxOD Width 18mm 50x 8 0 LxOD Shape 75539 GO D 1 Asshownin the figure peel off the shields from the rubber wire of the power cable Peel off 20 mm of the wire shields of the tube installed already A After peeling off the tube wire you must insert a contraction tube CAUTION 2 Insert both sides of core wire of the power cable into the connection sleeve 3 Using a compressor compress the two points and flip it over and compress another two points
11. controller set temperature Fan Fan mode can be selected to ventilate your room Fan mode will be helpful to refresh the stale air in your room 10 Press the button to turn on the air conditioner Press the button to set the operating mode Each time you press the Mode button the mode will change in order of Auto Cool Dry and Fan HSITDNA Press the button to set the desired fan speed Auto Sb gf Auto Cool So pf Auto Low Hyg Med Saal High Dry SH gf Auto Fan So Low ong Med SP pf High Press the button to adjust the temperature Auto You can adjust the desired temperature by 1 C within the range of 16 C 30 C Cool You can adjust the desired temperature by 1 C within the range of 16 C 30 C Dry You can adjust the desired temperature by 1 C within the range of 18 C 30 C Fan Temperature adjustment is not possible gt i Airflow can be adjusted manually see page 12 for instructions 11 Panama ASV12P IBIM DB68 03248A EN 2 indd 11 2015 7 13 19 21 41 aaa CSN NG Adjusting the air flow direction Air flow can be directed to your desired position I Vertical air flow Air flow blades move up and down Press the Air swing button on the remote controller gt Air swing indicator will be on and air flow blades move up and down continuously to circulate the ai
12. food animals plants or cosmetics or for any other unusual purposes gt This may result in property damage Avoid directly exposing humans animals or plants from the air flow from the air conditioner for long periods of time gt This may result in harm to humans animals or plants This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance FOR CLEANING A WARNING O Do not clean the appliance by spraying water directly onto it Do not use benzene thinner or alcohol to clean the appliance gt This may result in discoloration deformation damage electric shock or fire Before cleaning or performing maintenance unplug the air conditioner from the wall socket and wait until the fan stops gt Failing to do so may result in electric shock or fire FOR CLEANING A cauTION O O Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges gt To avoid cutting your fingers wear thick cotton gloves when cleaning it Do not clean the inside of the air conditioner by yourself gt For cleaning inside the appliance contact your nearest service center gt When cleanin
13. in the same location The compression dimension should be 8 0 After compressing it pull both sides of the wire to make sure it is firmly pressed 4 Wrap it with the insulation tape twice and position your contraction tube in the middle of the insulation tape 6 After tube contraction work is completed wrap it with the insulation tape to finish Apply heat to the contraction tube to contract it Unit mm Power cable provided by us 120 180 Wire tube power cable pa Connection sleeve Insulation tape bd 40mm Contraction tube Insulation tape Incase of extending the electric wire please DO NOT use a round shaped pressing socket WARNING Panama ASV12P IBIM DB68 03248A EN 2 indd 41 Incomplete wire connections can cause electric shock or a fire AJ 41 HSITDNA 2015 7 13 19 21 51 QUESTIONS OR COMMENTS COUNTRY CALL OR VISIT US ONLINE AT MEXICO 01 800 SAMSUNG 726 7864 www samsung com mx support BRAZIL 0800 124 421 Demais cidades e regi es 4004 0000 Capitais e grandes centros www samsung com br support COSTA RICA 0 800 507 7267 00 800 1 SAMSUNG 726 7864 www samsung com latin support Spani www samsung com latin en support Engli DOMINICAN REPUBLIC 1 800 751 2676 ECUADOR 1 800 10 7267 1 800 SAMSUNG 72 6786 ai www samsung com latin_en support Engli ai a Www samsung convlatin support
14. on the outdoor unit heat con EXchanger I Opening the panel Tightly grab top of the front panel and pull it down to open Then slightly lift the panel up 18 Panama ASV12P IBIM DB68 03248A EN 2 indd 18 RRR IOS RRS nee 2o RARES RRR ess ares ba ta amp ve 2S ERR PERN RRR SRR RRS RAG 2 RS cerns Se HAS Heat exchanger Illustration may differ slightly depending on the models 2015 7 13 19 21 44 Panama ASV12P IBIM DB68 03248A EN 2 indd 19 2015 7 13 19 21 45 I Removing the Air filter Grab the handle and lift it up Then pull the Air filter towards you and slide it down HSITDNA Cleaning the air filter Washable foam based air filter captures large particles from the air The filter is cleaned with a vacuum or by hand washing Open the panel and put the Air filter out Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy rinse it with running water Insert the Air filter back in its original position Dry the Air filter in a ventilated area and close the front panel Clean the Air filter every 2 weeks or when the filter clean reminder lights up Cleaning term may differ depending Note onthe usage and environmental conditions In dusty area clean it once a week Ifyou turn off the air conditioner by pre
15. unit to the installation plate and move the unit to the plate Connecting right and left until it is securely in place Vinyl tape Connecting wires 4 Make sure pipe does not move when you install the indoor unit on f A Drain hose cumon _ a installation plate 5 Wrap the rest of the pipe with vinyl tape 6 Attach the pipe to the wall using clamps optional Fixing the outdoor unit in place Install the outdoor unit in level on a stable base to avoid the generation of noise and X mm vibration especially when installing the unit close to a neighbor 5 A If you install the outdoor unit in a place exposed to strong winds or at a height fix it to an E appropriate support wall or ground 1 Place the outdoor unit as indicated on the top of the unit to let the discharged air Rubber leg out properly Model X Y 2 Fix the outdoor unit in level to an appropriate support using anchor bolts ASVOOPA 457 254 ASV12PX X 538 290 3 Ifthe outdoor unit is exposed to strong winds install shield plates around the ASV18PXX 612 317 outdoor unit so that the fan can operate correctly ASV24PXX 660 340 B Secure the rubber leg to prevent the generation of noise and vibration NOTE Outdoor unit installed on the wall by rack Ensure the wall will be able to suspend the weight of rack and outdoor unit Install the rack close to the column as much as possible Install proper grommet in order to reduce noise and residual
16. valve of the low pressure side of manifold gauge clockwise gt Turn off the vacuum pump gt Check for 2 minutes if there is any pressure change gt Remove the hose of the low pressure side of manifold gauge 6 Seta valve cork of liquid and gas service port to the open position Panama ASV12P IBIM DB68 03248A EN 2 indd 35 Indoor unit P Gas pipe side KI Liquid pipe side gt lt Outer Torque Diameter Nem kgfecm 06 35 mm 14 18 140 180 99 52 mm 34 42 350 430 912 70 mm 49 61 500 620 15 88mm 68 82 690 830 amp Manifold gauge Valve Gas service port lt Low pressure gt Liquid service port lt High pressure gt Vacuum Pump Backward flowing prevention 35 2015 7 13 19 21 50 MEMES Purging the connected pipes Adding Refrigerant Add refrigerant charge according to table below A 4 or 5 meter pipe is supplied with the air conditioner If you use a pipe longer than 4 or 5m Ag of refrigerant R410A must be added for each extra meter If you use a pipe shorter than 4 or 5 m The purge time is normal Refer to the Service Manual for further details The remaining air in the Refrigeration cycle which contains moisture may cause malfunction on the compressor Model 09 12 XK18 24KX caution Always contact the service center or a professional installation agency for prod
17. 2 amp This check mark requires checking the indoor outdoor unit periodically following to the description to maintain the air conditioner properly 1 The described operations should be performed more frequently if the area of installation is very dusty NOTE 2 These operations must always be performed by qualified personnel For more detailed information see the installation part in the manual 20 Panama_ASV12P _IBIM_DB68 03248A_EN 2 indd 20 2015 7 13 19 21 45 Panama_ASV12P _IBIM_DB68 03248A_EN 2 indd 21 Troubleshooting Refer to the following chart if the air conditioner operates abnormally This may save time and unnecessary expenses HSITDNA PROBLEM SOLUTION The air conditioner does Check power status and then operate the air conditioner again not work at all Plugin or switch on the circuit breaker and then operate the air conditioner again e Check if you have set the Off Timer Operate the air conditioner again by pressing the Power button The temperature Check if you have selected Fan Turbo mode In these modes desired temperature is set to adjustment is not working auto and you cannot adjust the temperature Cool Warm air does not come out of the air conditioner Check if the set temperature is higher during Cool mode than the current temperature Press the Temp or button on the remote controller to change the set temperature Check if the Air filter
18. In the event of a gas leak such as propane gas LP gas etc ventilate immediately without touching the power plug Do not touch the appliance or power cord gt Donot use a ventilating fan gt Aspark may result in an explosion or fire To reinstall the air conditioner please contact your nearest service center gt Failing to do so may result in problems with the product water leakage electric shock or fire gt A delivery service for the product is not provided If you reinstall the product in another location additional construction expenses and an installation fee will be charged gt Especially when you wish to install the product in an unusual location such as in an industrial area or near the seaside where it is exposed to the salt in the air please contact your nearest service center Do not touch the power plug or the circuit breaker with wet hands gt This may result in electric shock Do not unplug the power plug or turn the air conditioner off with the circuit breaker while it is operating gt Plugging the power plug into the wall outlet or turning the air conditioner on from the circuit breaker may cause a spark and result in electric shock or fire After unpacking the air conditioner keep all packaging materials well out of the reach of children as packaging materials can be dangerous to children gt Ifa child places a bag over its head it may result in suffocation Do not insert your fingers or f
19. OLIVIA 800 10 7260 HHP 4828210 www samsung com cl support PERU 0800 777 08 www samsung com pe support ARGENTINE 0800 555 SAMSUNG 0800 555 7267 www samsung com ar support URUGUAY 000 405 437 33 www samsung com latin support Spanish www samsung com latin_en support English PARAGUAY 009 800 542 0001 Panama_ASV12P _IBIM_DB68 03248A_EN 2 indd 42 www samsung com latin support Spanish www samsung com latin_en support English 2015 7 13 19 21 52 ASVO9P Series ASV12PX X Series ASV18P Series ASV24P Series 100 Recycled Paper imagine the possibilities Thank you for purchasing this Samsung product MWEE DB68 03248472 ex Panama ASV12P IBIM DB68 03248A EN 2 indd 43 2015 7 13 19 21 52
20. and malfunction Refrigerant for air purging is not charged in the outdoor unit Use Vacuum Pump as seen in the picture When installing make sure there is no leakage When recovering the refrigerant ground the compressor first before removing the connection pipe If the refrigerant pipe is not properly connected and the compressor works HSITDNA with the service valve open the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high It may cause explosion and injury 1 Connect each assembly pipe to the appropriate valve on the outdoor unit and Outdoor unit tighten the flare nut 2 Tighten the flare nut first with your hands and then with a torque wrench applying the following torque B Excessive torque can be cause of gas leakage NOTE Make the electrical connection and leave the system into stand by mode Do not turn on the system This is necessary for better vacuum operation full OPEN position of Electronic Expansion Valve EEV 3 Connect the charging hose of the low pressure side of manifold gauge toa gas service port as seen in the picture 4 Open the valve of the low pressure side of manifold gauge counterclockwise 5 Purge the air in the connected pipes using the vacuum pump for about 15 minutes gt Make sure that pressure gauge shows 0 1MPa 76cmHg after about 10 minutes This procedure is very important to avoid a gas leak gt Close the
21. art Saver see pages 10 11 for instructions Less energy usage makes your space cool between the temperature range of 24 C 30 C Quiet Reduce noise generated from an indoor unit during operation Turbo wine Operate in auto fan speed to cool quickly Air swing Activate Deactivate air flow blade movement automatically up and down Temp Fanav Increase Decrease the temperature by 1 C Adjust how much air flows through the air conditioner with the 4 different fan speeds D such as Auto Low Medium High amp Temp Humi d light Cool Has no this funtion good Sleep Filter Reset Beep Off Display Off Auto Clean Auto clean function Dry inside of the indoor unit to get rid of odor good sleep Set the good sleep mode on On Timer Set Cancel Set the On Timer on Cancel the timer good sleep mode Off Timer 204 Switch the function of the button on the remote controller Set the Off Timer on SAMSUNG Filter Reset Reset the Filter Clean reminder Beep off To silence the beep sound when pressing the button Display off Has no this function When you press 2 4F button the BE indicator will be displayed on the remote controller and you can change the functions on the remote controller as listed below Auto Clean gt Filter Reset Temp Humi Beep Off good sleep gt Display Off function If you select the function under the button while the function of the button is switched b
22. be turned off in an unoccupied areas The heat may be caused by the excessive lighting or equipment that is turned on unnecessarily You should reduce heat in the air conditioned area 6 Panama_ASV12P _IBIM_DB68 03248A_EN 2 indd 6 2015 7 13 19 21 39 ZS CON NG Checking the name of the parts Your air conditioner may slightly look different from illustration shown above depending on your model Main parts HSITDNA Room temperature sensor nan Air filter under the panel Air flow blade up and down Blade pin lever Air flow blade left and right Display o Virus Doctor indicator O A Timer Auto clean indicator o Operation indicator j Power l button a Remote controller receiver Panama ASV12P IBIM DB68 03248A EN 2 indd 7 2015 7 13 19 21 40 ZS CSN NG Checking the remote controller Point the remote controller towards the remote controller receiver of the indoor unit When you properly press the button on the remote controller you will hear beep sound from the indoor unit and a transmit indicator appears on the remote controller display I Remote controller buttons Remote controller display Power Turn on off the air conditioner Virus Doctor Mode Set the Virus Doctor function on off Set one of the 4 operating modes Sm
23. bles make sure terminal numbers on the indoor outdoor unit matches CAUTION Screws on terminal block must not be unscrewed with the torque less than 12kgf cm 10 Connect the grounding conductor to the grounding terminals 11 Close the terminal board cover by tightening the screw carefully In Russia and Europe consult with the supply authority to determine the supply system impedance before Note installation Connect the wires firmly so that wires can not be pulled out easily A If they are loose it could cause burn out of the wires WARNING Connect the wires according to color codes referring to the wiring diagram The power cable and the interconnection cable should be selected according to the specification in page 29 30 Panama ASV12P IBIM DB68 03248A EN 2 indd 30 2015 7 13 19 21 49 Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field supplied copper pipes by means of flare connections Use insulated seamless refrigeration grade pipe only Cu DHP type according to 1S01337 degreased and deoxidized suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa Under no circumstances must sanitary type copper pipe be used There are 2 refrigerant pipes of different diameters The smaller one is for the liquid refrigerant The larger one is for the gas refrigerant A short pipe is already fitted to the ai
24. ce should be positioned in such a way that it is accessible to the power plug gt Failing to do so may result in electric shock or fire due to electric leakage Install your appliance on a level and hard floor that can support its weight gt Failing to do so may result in abnormal vibrations noise or problems with the product Install the draining hose properly so that water is drained correctly gt Failing to do so may result in water overflowing and property damage When installing the outdoor unit make sure to connect the draining hose so that draining is performed correctly gt The water generated during the heating operation by the outdoor unit may overflow and result in property damage In particular in winter if a block of ice falls it may result in injury death or property damage Panama ASV12P IBIM DB68 03248A EN 2 indd 3 2015 7 13 19 21 39 Safety precautions FOR POWER SUPPLY WARNING Q Remove all foreign substances such as dust or water from the power plug terminals and contact points using a dry cloth on a regular basis gt Unplug the power plug and clean it with a dry cloth gt Failing to do so may result in electric shock or fire Plug the power plug into the wall socket in the right direction so that the cord runs towards the floor gt Ifyou plug the power plug into the socket in the opposite direction the electric wires within the cable may be damaged and his may result in electric sho
25. ck or fire When the appliance or power plug or power cord is damaged contact your nearest service center Plug the power plug into the wall socket firmly Do not use a damaged power plug damaged power cord or loose wall socket gt This may result in electric shock or fire Do not pull the power cord when unplugging the power plug gt Unplug the power plug by holding the plug gt Failing to do so may result in electric shock or fire Do not pull or excessively bend the power cord Do not twist or tie the power cord Do not hook the power cord over a metal object place a heavy object on the power cord insert the power cord between objects or push the power cord into the space behind the appliance gt This may result in electric shock or fire FOR POWER SUPPLY A CAUTION When not using the air conditioner for a long period of time or during a thunder lightning storm cut the power at the circuit breaker gt Failing to do so may result in electric shock or fire FOR USING WARNING Q 4 Panama_ASV12P _IBIM_DB68 03248A_EN 2 indd 4 2015 7 13 19 21 39 If the appliance is flooded please contact your nearest service center gt Failing to do so may result in electric shock or fire If the appliance generates a strange noise a burning smell or smoke unplug the power plug immediately and contact your nearest service center gt Failing to do so may result in electric shock or fire
26. e d light Cool function Press the d light Cool button while the air conditioner is operating in Cool mode Fan speed is set to Auto and air flow blades move up and down continuously Cancel Press the d light Cool button once again l Press the d light Cool button once again Fan speed remain Auto speed NOTE The air conditioner has no d light Cool function 17 Panama ASV12P IBIM DB68 03248A EN 2 indd 17 2015 7 13 19 21 44 Cleaning the air conditioner Make sure the power is turned off and unplugged from curon the wall socket when cleaning the air conditioner Cleaning the indoor unit gt Wipe the surface of the unit with a slightly wet or dry cloth when needed Contact the service center when you clean the indoor unit Note heat exchanger because it needs to be disassembled Do not clean the display using alkaline detergent caution Do not use sulfuric acid hydrochloric acid organic solvents such as thinner kerosene and acetone etc to clean the surface of the product or put any stickers on it They may damage the surface of the air conditioner Cleaning the outdoor unit heat exchanger gt When dust accumulates on the heat exchanger it may decrease cooling performance Therefore clean it regularly b Spray water to clean the dust Ifit is difficult to clean the outdoor unit heat exchanger on NOTE Your own contact service center Be careful with the sharp edges
27. eep mode However if you select good sleep mode while heating operation is on you can adjust air flow direction AQ 2k model Temperature and fan speed changes in good sleep mode Fall asleep Eases you into sleep by dropping the temperature Sound sleep Relaxes your body and raises your temperature slightly Wake up from good sleep mode Allows you to wake up from comfortable intermittent air and it makes you feel refreshed Set Off timer in good sleep mode over 5 hours You fell disturbed sleep if the good sleep is set too short or long note because the default is set to 8 hour operation Ifthe good sleep mode is set less than 4 hours the operation will stop at the same time If the good sleep mode is set over 5 hours it will run as Wake up stage from the last one hour before it stops Recommended set temperature is between 25 C 27 C for cooling 13 Panama ASV12P IBIM DB68 03248A EN 2 indd 13 2015 7 13 19 21 42 Setting the On Off timer You can set the air conditioner to turn on off automatically at desired time Setting On timer while the air conditioner is off Off timer while the air conditioner is on Setting On timer Temp d pur pur E re E re Filter Reset Beep Off Display Off On Off S Ne Cance Setting Off timer Fan d light Auto Temp good Clean Humi sleep Filter Reset Beep O
28. ency rated current condition is different it may cause fire The installation of this appliance must be performed by a qualified technician or service company gt Failing to do so may result in electric shock fire explosion problems with the product or injury Install a switch and circuit breaker dedicated to the air conditioner gt Failing to do so may result in electric shock or fire Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed gt Failing to do so may result in electric shock or fire O Do not install this appliance near a heater inflammable material Do not install this appliance in a humid oily or dusty location in a location exposed to direct sunlight and water rain drops Do not install this appliance in a location where gas may leak gt This may result in electric shock or fire Never install the outdoor unit in a location such as on a high external wall where it could fall gt Ifthe outdoor unit falls it may result in injury death or property damage This appliance must be properly grounded Do not ground the appliance to a gas pipe plastic water pipe or telephone line gt Failure to do so may result in electric shock fire an explosion or other problems with the product gt Never plug the power cord into a socket that is not grounded correctly and make sure that it is in accordance with local and national codes FOR INSTALLATION A caution O This applian
29. eria pollen and odor It makes you breathe better as if you are staying around waterfalls ocean surf rivers and mountains Panama_ASV12P _IBIM_DB68 03248A_EN 2 indd 2 Safety PrecAULIONS A kinikimkim Checking before use Checking the name of the parts Checking the remote controller Basic FUNCTION unan Adjusting the air flow direction Using the Turbo function good sleep mode Setting the On Off timer Using the Smart Saver function Using the Virus Doctor function Using the Auto Clean function Using the Quiet function Using the d light Cool function Cleaning the air conditioner Maintaining the air conditioner Troubleshooting INSTALLATION PARTS Safety precautions Choosing the installation location ACCESSONES sisicssiistesiescsantsessies Fixing the installation plate Connecting the assembly cable ssssssssssssssssssssssssssossssssssssse 29 nstalling and connecting the assembly pipe of the indoor unit Purging the indoor unit Cutting or extending the pipe nstalling and connecting the drain hose of the indoor unit 33 Changing direction of the drain hose esses 34 nstalling and connecting the Purging the connected pipes Performing the gas leak tests Fixing the indoor unit in place Fixing the outdoor unit in place Final check and trial operation Pump down procedure when removing the product How to connect your extended power cables
30. erted the batteries in locked properly correct position The signal may not be received well of electronic lighting style fluorescent lamps such as inverter fluorescent lamps Note arein the same space If other electrical products operate by the remote controller call your nearest contact center 9 Panama ASV12P IBIM DB68 03248A EN 2 indd 9 2015 7 13 19 21 40 Panama ASV12P IBIM DB68 03248A EN 2 indd 10 2015 7 13 19 21 40 Basic function Basic operation is an operation mode that can be selected by pressing the Mode button Auto In Auto mode the air conditioner will automatically set the temperature and fan speed depending on the room temperature detected by the room temperature Cool In Cool mode the air conditioner will cool your room You can adjust the temperature and the fan speed to feel cooler in hot season If current outside temperatures are much higher than the selected indoor temperature it may take time to bring the inner temperature to the desired coolness Quiet mode pf makes the noise quieter during operating the indoor unit in the Cool mode Dry The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air Dry mode makes the air feel refreshing in a humid climate To maximize the dehumidification capacity during the Dry operation the air conditioner could be operating at lower or higher temperature than the remote
31. ff Display Off Temp On Off Set Timer EN Auto SET Ke pa Lt OFF 14 Kal Press the On Timer Off Timer button gt On Off timer indicator will blink on the remote controller display Press the On Timer Off Timer button to set the time gt You can set the time in half hourly unit from 30 minutes 3 hours and hour unit from 3 hours 24 hours gt Operating hour can be set from minimum 30 minutes to maximum 24 hours Press the Set Cancel button to active it on gt On timer indicator stops blinking and reserved time will be displayed for 3 seconds gt Ifyou don t press Set Cancel button within 10 seconds after selecting the time the air conditioner will return to previous status Check On timer or Off timer indicator and 3 indicator on the indoor unit Cancel Press the Set Cancel button Additional options available in On timer mode You can select from Auto Cool Dry Fan mode Temp You can adjust the temperature in Auto Cool Dry mode Only the latest setting timer will be applied between the On Timer Off Timer note andgood sleep Off timer functions After setting the timer the set time will be displayed for 3 seconds before it disappears Panama ASV12P IBIM DB68 03248A EN 2 indd 14 2015 7 13 19 21 43 Combining On Timer and Off Timer If the air conditioner is on If the air conditioner is off Preset time on On timer i
32. g table Model Names Included Models Remark ASVXXPX ASV 09PX ASV12P ASV 18P ASV 24P Grouping was done by series XXKO09XX ASV 09PX XXK12XXK ASV12PX ree ASV BPX Grouping was done by capacity X 24 ASV24P HSITDNA Safety precautions Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components Verify that installation and testing operations are performed by qualified personnel Verify that the air conditioner is not installed in an easily accessible area General information gt v v Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation For maximum safety installers should always carefully read the following warnings Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred This manual explains how to install an indoor unit with a split system with two SAMSUNG units The use of other types of units with different control systems may damage the units and invalidate the warranty The manufacturer shall not be responsible for damages arising from the use of non compliant units
33. g the internal filter refer to the descriptions in the Cleaning the air conditioner section gt Failure to do may result in damage electric shock or fire Panama ASV12P IBIM DB68 03248A EN 2 indd 5 2015 7 13 19 21 39 ZS CSN NG Checking before use I Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within Refer to the table for efficient use Mode Indoor Outdoor tan Indoor humidity Remark temperature perature A p 10 C 46 C mo ASV18 24 Cooling 16 C 32 C 16 C 46 C Relative humidity 80 or less ASVO9 12X a f 10 C 46 C ASV18 24 Dry ECC cac ASVO9 12X gt If the air conditioner operates in cooling mode for long period of time in high humidity area dew may be formed Maintaining your air conditioner Internal protections via the unit control system gt This internal protection operates if an internal fault occurs in the air conditioner Type Description Anti protection of The compressor will be off to protect internal battery when the air conditioner operates internal battery in Cool mode The air conditioner does not start operating immediately to protect the compressor of Protect compressor P the outdoor unit after it has been started We suggest that the temperature should be set between 21 C 23 C to reduce energy consumption NOTE The air conditioner should
34. han 4 or 5 meters caution You must extend the assembly cable You must add refrigerant to the pipes otherwise the indoor unit may freeze 1 Make sure that you have all the required tools pipe cutter reamer flaring tool and pipe holder 2 Ifyou want to shorten the pipe cut it using a pipe cutter ensuring that the cut edge remains at 90 with the side of the pipe see below examples of correct and incorrect cut edges Pipe 90 Oblique cutter Pipe 3 To prevent a gas leak remove all burrs at the cut edge of the pipe using a reamer A Face the pipe down while removing the burrs to make sure that burrs do not get in to the pipe CAUTION 4 Puta flare nut slightly into the pipe and modify the flare Outer Diameter D Depth A Flaring Size B 06 35 mm 1 3mm 8 7 9 1 mm 99 52 mm 1 8mm 12 8 13 2mm 612 70 mm 2 0mm 16 2 16 6 mm 615 88 mm 2 2mm 19 3 19 7 mm E E 32 Panama ASV12P IBIM DB68 03248A EN 2 indd 32 2015 7 13 19 21 49 5 Check if you flared the pipe correctly see examples of incorrectly flared pipes below Correct Inclined Damaged Cracked Uneven Surface Thickness HSITDNA 6 Align the pipes to connect them easily Tighten the flare nuts first with your hands and then with a torque wrench applying the following torque Torque Flare nut Outer Diameter kgf cm 06 35 mm 140 180 99 52 mm 350
35. he connecting part of the terminal socket is facing upwards ist Upside down The terminal There is no ring socketis damaged terminalto cover the wire gt There must de no space between the terminal and the screw when connected Any remaining space may become a fire hazard due to overheating of the electrical contact 1 Either the screw is not fitted properly The terminal socket or there is a space between the screw is upside down and the ring terminal ror the terminal block wiring use a wire with a ring terminal socket only ular wires without a ring terminal socket may become a fire hazard due to overheating CAUTION Of ine electrical contact during a wiring work 29 Connecting the assembly cable When you install the unit make first refrigerant connections and then electrical connections Connect the air conditioner to grounding system before performing the electrical connection If unit is uninstalled first disconnect electrical cables then refrigerant connections A4 or 5 meter pipe is supplied with the air conditioner If the outdoor unit is more than 4 or 5 meters away from the indoor unit you must extend the cable The maximum length of the cable is 15 09 12 20 18 24 meters 1 Extend the assembly cable if necessary Do not connect two or more different cables to extend the length caron lt may cause fire 2 Open the front grille 3 Remove the screw securing the connect
36. he installation and the gas leak test Note referto page 38 for further details Tighten the flare nut with torque wrench according to specified method cauron lf the flare nut is over tightened the flare may break and cause refrigerant gas leakage DO NOT WALL UP THE PIPE CONNECTION All refrigerant pipe connection must be easy accessible and serviceable 31 HSITDNA Panama ASV12P IBIM DB68 03248A EN 2 indd 31 2015 7 13 19 21 49 Purging the indoor unit The indoor unit is supplied with inert gas nitrogen Before installing the unit check if nitrogen gas flow out of indoor unit If this one isn t true DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit 1 Unscrew the caps at the end of each pipe gt All inert gas exhausts from the indoor unit To prevent dirt or foreign substances from getting into the pipes during Hah tee Note installation do NOT remove the caps completely until you are ready to connect the pipes The remaining air in the Refrigeration cycle which contains moisture caution May cause malfunction on the compressor Always contact the service center or a professional installation agency for product installation Pipes Unscrew the caps Cutting or extending the pipe The length of the pipe can be Extended up to see table page 25 Shorten up to see page 25 If you need a pipe longer t
37. he standard fuse gt Failing to do so may result in electric shock fire problems with the product or injury FOR USING A cauTION O Do not place objects or devices under the indoor unit b Water dripping from the indoor unit may result in fire or property damage Check that the installation frame of the outdoor unit is not broken at least once a year gt Failing to do so may result in injury death or property damage Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency Do not stand on top of the appliance or place objects such as laundry lighted candles lighted cigarettes dishes chemicals metal objects etc on the appliance gt This may result in electric shock fire problems with the product or injury Do not operate the appliance with wet hands gt This may result in electric shock Do not spray volatile material such as insecticide onto the surface of the appliance gt As well as being harmful to humans it may also result in electric shock fire or problems with the product Do not drink the water from the air conditioner gt The water may be harmful to humans Do not apply a strong impact to the remote controller and do not disassemble the remote controller Do not touch the pipes connected with the product gt This may result in burns or injury Do not use this air conditioner to preserve precision equipment
38. ing your remote controller sensor Check that there are strong lighting apparatus near the air conditioner Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves Timer function does not set Check if you press the Set Cancel button on the remote controller after you have set the time The indicator is blinking continuously Press the Power button or disconnect the power plug switch off the auxiliary power switch If the indicator is still blinking contact the service center Odors permeate in the room during operation Check if the appliance is running in a smoky area Ventilate the room or operate the air conditioner in Fan mode for 1 2 hours We do not use smelly components in the air conditioner 21 2015 7 13 19 21 45 Troubleshooting PROBLEM SOLUTION Error is indicated When an indoor unit indicator blinks contact the nearest service center Noise is generated Depending on the status of the air conditioner usage noise can be heard when refrigerant flow movement changes It is normal Water is dropping from the outdoor unit piping connection Water may be generated because of the temperature difference It is normal 22 Panama ASV12P IBIM DB68 03248A EN 2 indd 22 2015 7 13 19 21 45 INSTALLATION PARTS X In this manual you may find model names written in simplified forms as indicated in followin
39. is blocked by dirt If there is a lot of dust on the Air filter cooling performance may decrease Clean them frequently Check if the outdoor unit is covered or installed near the obstacle Take the cover off and take the obstacle away If you want to operate the air conditioner in the sunlight cover the outdoor unit using curtains or etc Check if the air conditioner is operating in De ice mode When the ice formed in winter or the outdoor temperature is too low the air conditioner operates in De ice mode automatically In De ice mode indoor fan stops and cool air does not come out If the doors or windows are open it may cause bad cooling performance Close the doors and windows Check if the air conditioner has just been turned on after stopping cooling operation In this case just a fan will run to protect the outdoor unit compressor Check if the pipe length is too long When the pipe length exceeds maximum allowable pipe length cooling performance may decrease Air flow adjustment is not w