Home

Samsung AQV12VBE User Manual

image

Contents

1. Temperature and Humidity Ranges If you check the following tables you can use your air conditioner more efficiently If the air conditioner is used at Then Heating capacity The air conditioner may stop operating for the reason of protection Low temperatures Water may leak and some malfunction may occur if the heat exchanger freezes Water may condense and drip from the surface of the indoor unit if you don t use Protection mechanism the air conditioner for an extended period of time Operation Outdoor Temperature Indoor Temperature Indoor Humidity 5 F to 75 F approx 80 F or less Heating E m F gt 15 C to 24 C approx 27 C or less 14 F to 115 F approx 61 F to 90 F approx Cool 80 or less nn 10 C to 46 C approx 16 C to 32 C approx 14 F to 115 F approx 61 F to 90 F approx 10 C to 46 C approx 16 C to 32 C approx Dehumidifying x Ifthe outdoor temperature is as low as 32 F 0 C the heating capacity drops up to 70 80 depending on the operating condition If you use the air conditioner in temperatures over 90 F 32 C indoor temperature the cooling capacity may drop Operating Recommendations When you use your air conditioner it is recommended that you read the following Topic Heating capacity Warm air circulation Frost High indoor and outdoor temperatures Power failure Protection mechanism Cooling operation Silence Mode Recommendation
2. gt Do not install the unit in a Do not install the outdoor Do not connect the ground place where it is exposed to unit where there s the risk of to a gas pipe water pipe inflammable gas leakage dropping such as on high lightning rod or telephone outer wall or outside of the earth terrace The installation must be carried out by a licensed installer or qualified personnel when installing the unit for the first time or reinstalling it Contact the service center if the air conditioner is under water REGARDING POWER SOURCE gt Do not pull the electric wire gt Install the switch and circuit or touch the power plug with breaker only for the wet hands air conditioner gt Do not bend the electric wire Use the power source with Ifthe power plug is by force or weigh down the separate wiring onlyforair damaged replace it by the air conditioner not to be out conditioner manufacturer or qualified of order personnel to avoid the risk When using a wireless remote control the distance should not be more than 7 meters from the air conditioner If applicable Do not attempt to repair move modify or reinstall the unit on your own Make sure that these installations are carried out by qualified personnel to avoid electric shock or fire The manufacturer
3. The air conditioner turns on automatically at the appointed time and the On Timer setting disappears w Ar gt Up Down OD Ce 4 Press the 5 button until the desired mode is displayed at the top of the remote control to select the mode in advance Result The air conditioner operates in the selected mode when it is turned on The most recently used function is set between On and Off Timer to turn on off the air conditioner and good sleep mode On Timer of mpizone mode cannot be set out separately 7 A amp Set Cancel 2 CI To Cancel the On Timer 1 Press the button to cancel the On Timer If you press the button both the On Timer and the Off Timer are canceled gt Fes n v 4E u set Cancel Setting the Off Timer You can set the Off Timer to turn off the air conditioner automatically at the appointed time within a range of 30 minutes to 24 hours 1 Press the button 2 Press the cay or Cy buttons until the desired time is displayed to set the Off Timer You can set the time between 0 5 hour and 24 hours 3 Press the button to complete the setting Result The remaining time is displayed The timer indicator stops blinking The air conditioner turns off automatically at the appointed time and the Off Timer setting disappears If you would like to turn the air conditioner on after 2 hours and to operate it for 2 hours during no
4. When you need to dispose of the unit consult your dealer If pipes are removed incorrectly refrigerant may blow out and come into contact with your skin causing injury Releasing refrigerant into the atmosphere also damages the environments Install the outdoor unit so as to let the discharged air out properly Avoid a place that may disturb your neighbor by noise Please recycle or dispose of the packaging material for this product in an environmentally responsible manner Install the drain hose to let the water run safely and correctly CAUTION REGARDING POWER SOURCE Disconnect the circuit breaker Contact the service center or Contact the service center when you don t use the manufacturer if you wantto after turning off the air air conditioner for along time repair the air conditioner conditioner if strange noise to save energy js heard burning smell or smoke blow DURING OPERATION Do not open the front grille gt Avoid cold and hot air gt Avoid the water from during operation reaching to person petora getting into the plant directly for a long time air conditioner gt Do not use the air conditioner Do not step
5. Swing button ST Fan speed adjustment button Digital z On Off button Turbo button CLEAN I Auto Cleaning button CIN iene button We Maan button Energy saving button Ki On Timer button mis St Timer Set Cancel button On Off Clean Mode Off Timer nal C gt mpizone mode men button Time adjustment wend Ty ee On Off button Digital 7 On Off button If you want to turn on or off the Display of the indoor unit during SAMSUNG operation press the gt button on the remote cone Inserting the Remote Control Batteries You must insert or replace the remote control batteries when You purchase the air conditioner The remote control does not work correctly Use two AAA LRO3 1 5V batteries Do not use old and new batteries or different kinds of batteries together Insert two batteries correctly as indicated by the and symbols 1 Remove the battery cover in the rear of the remote control by pushing it with your thumb 2 Insert two batteries respecting the polarities as indicated by the and symbols 3 Close the cover by sliding it back in place Correct disposal of batteries in this product Applicable in the European Union and other European countries with separate battery return systems This marking on the battery manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life Where ma
6. The heat pump inside the air conditioner absorbs heat from outside air and brings itindoors If the temperature of the outside air drops the air conditioner heats less If the room is not warm enough use an additional heating appliance The air conditioner circulates warm air to heat your room It will take some time to warm the air in your room entirely after the air conditioner turns on Therefore turn the air conditioner on in advance When you select the Heat mode frost may form in the outdoor unit due to low temperature and high humidity If this happens The heating operation is stopped The air conditioner defrosts automatically for about 7 minutes After about 7 minutes the air conditioner starts operating again normally If both the indoor and outdoor temperatures are high when you select the Heat mode the fan and the compressor of the outdoor unit may stop periodically This is normal wait until the air conditioner turns on again If a power failure occurs when the air conditioner is operating the air conditioner will turn off When the power returns the air conditioner will start up again automatically When the air conditioner is started immediately after being plugged in or stopped the normal operation starts up after 3 minutes for the reason of protection The indoor unit may not get the selected fan speed such as Medium and Low under cooling operation at very low outdoor temperatures for the protection of the
7. The indoor unit beeps each time you press the button The air conditioner runs in Auto mode Auto mode cools or heats the room depending on the set temperature The air conditioner changes from Cool or Heat mode automatically depending on the current temperature You can change modes at any time 3 Press the button to adjust the temperature until the required temperature is displayed You can set the temperature between 61 F 16 C and 86 F 30 C Result Each time you press the button The temperature adjusts by 1 F The indoor unit beeps The fan speed adjusts automatically Selecting Cool Mode You can select Cool mode if you want to cool your room You can adjust the temperature and the fan speed when cooling 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps ode 2 Pressthe button on the remote control until Cool is displayed Result The indoor unit beeps each time you press the button The air conditioner runs in Cool mode You can change modes at any time 3 Press the button to adjust the temperature until the required temperature is displayed You can set the temperature between 61 F 16 C and 86 F 30 C Result Each time you press the button Set Temp The temperature adjusts by 1 F ITE The indoor unit beeps IL If the roo
8. The window or door may be opened Check if you turn on the air conditioner just now It takes about 3 minutes to cool or heat the room Check if the drain pipe is too long The fan speed is not adjusted In Auto or Dry mode the fan speed is selected automatically The remote control does Check ifthe battery is discharged Replace the battery not operate Checkif the remote control sensor is blocked Checkif the air conditioner is placed near strong light The Timer is not set Check if you pressed the 5 button after selecting time Odor is permeated in the Check if you use the air conditioner in smoky area or there is a smell room during operation Ventilate the room or select the Fan mode for 1 2 hours The indoor unit indicator Press the button to turn on the air conditioner again flashes Switch the circuit breaker off and switch on it again Strange sound is heard from The sound is heard when the refrigerant gas flow is changed depending the air conditioner on the use of the air conditioner When you press the button noise may be heard that the air conditioner sense the airflow blade Water drops from the outdoor Water may form due to the difference of the temperature unit connection part SYMPTOMS The abnormal signal is oc mo i co CIT Fels GEES BIER Al blink EEEN EEEN BIEN co Cul CLI J CUL CUILCE CUI NG BIER IEN IEA ENEN EEA EN displayed CHECK ERROR MODE DISPLAYED Some
9. Pressthe button Result The timer indicator is displayed The Off timer is blinking on the remote control 4 To set the good sleep Off timer press the A C buttons once or more times until the required Off time is displayed Result The good sleep mode will be automatically stopped in 8 hours if the operation time is not set You can set the Off timer by pressing the DD buttons to turn off the good sleep mode automatically at the appointed time within a range of 30 minutes to 12 hours Each time the DD buttons are pressed the time is increased by 30 minutes or 1 hour good sleep mode will be stopped at the appointed off time Set Cancel 5 Press the button Result The remaining time is displayed In the case of selecting good sleep mode or adjusting the extra time for good sleep mode you should press the 25 button Set Cancel within 10 seconds If you do not press the button within 10 seconds good sleep mode will be canceled automatically 6 Press the button to adjust the temperature until the desired temperature is displayed You can set the temperature between 61 F 16 C and 86 F 30 C Result Eadime you press the button The temperature adjusts by 1 F The indoor unit beeps Temperature changes in good sleep mode To prevent excessive cooling heating during sleep the good sleep mode automatically modifies the temperature setting in accordance with the time setting Tempe
10. declines any liability for damage resulting from modifications or errors in the electrical or hydraulic connections Do not place any obstacles in front of the unit Make sure that the unit is correctly ventilated at all times Do not place clothing or other materials over it Failure to observe the installation instruction or use of the unit under conditions other than those indicated in the table Operating limit of the unit installation manual will immediately invalidate the unit warranty Do not insert anything between the air outlet blades because the inner fan may be damaged and could cause injury Keep children away from the unit Never spill any kind of liquid into the unit Should this happen unplug or main switch off the unit and contact an authorized service center 4 If the wireless remote control is not used for a long time remove the batteries If applicable Do not connect the electric heater to the air conditioner or repair it with your discretion Do not place any materials so that children cannot step on it N WARNING DISPOSING THE UNIT N Before throwing out the device it is necessary to pull back the battery cells and get rid of them safely for recycling reasons CAUTION WHEN INSTALLING Install the air conditioner avoiding direct sunlight or heater especially water
11. indoor unit from ice or frost During Low fan speed operation cooling performance will be reduced If the room does not be cooled down when using Low fan speed operation please adjust the indoor unit s fan speed When you operate Silence Mode in cooling and heating fan speed will decrease to make noise quieter As a result the performance of the unit may be reduced Solving Common Problems Before contacting the after sales service perform the following simple checks They may save you the time and expense of an unnecessary call Problem Explanation Solution The air conditioner does not Check if power is on and operate the air conditioner again operate at all Check if the circuit breaker is switched off Check if Off Timer is set The temperature is not adjusted Check if you selected the Fan mode The air conditioner does not operate Check if the air conditioner is cooling only model in the HEAT mode Check if the remote control is for cooling only model The cool warm air does not come Check if set temperature higher lower than current temperature out from the air conditioner Check if you selected the Fan mode Select the Cool Heat Auto or Dry mode Check if the air filter is blocked by dirt Clean the air filter regularly Check if the there is cover on the outdoor unit or any obstacle Remove the cover or obstacle Check if you installed the air conditioner under direct sunlight
12. on the air gt Do not drink the water from for a long time in a closed room conditioner or put heavy the air conditioner or in a place where theresa object on it baby or an old person CAUTION DURING OPERATION Do not touch the pipes connected to the air conditioner OTHERS pet plant or cosmetics gt Do not use the air conditioner to maintain the machine food Do not give excessive shock to the air conditioner hen ww ZES Be sure that the air filter not to be exposed to direct sunlight Turn off the air conditioner and if the fan stops to operate clean the air conditioner Be sure to insert the air filter The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance a Do not clean the air conditioner by spraying water directly or with benzene thinner or alcohol Dispose of the packaging material in accordance with the local requirements The maximum input power amp current is measured according to the IEC standard and the input power amp current is measured according to the ISO standard The surface of the heat exchanger is sharp so b
13. signal is displayed on the window LED like GG EEN EES EHEN BER CUD md Kl MANAGEMENT This product has something wrong please call the nearest contact center CLI 71 cc GEE GR GS BER AA a ELECTRONICS COUNTRY CONTACT CENTER VISIT US ONLINE AT CANADA 1 800 SAMSUNG 726 7864 MEXICO 07 800 SAMSUNG 726 7864 USER S MANUAL AQVO9V Series AQV12Vx Series AQV18Vx Series AQV24Vxx Series Split type Air Conditioner Cooling and Heating TER TE ST E S F DB98 29982A 1 CT Cire C US Liy Sail 5 LISTED mr T a YW z Lu ESPANOL FRAN AIS
14. Contents PREPARATION E Safety PrecautlONs sananen i 3 B Name or Each PM een e 8 m Remote Control Buttons and Display nnnansssennnsooesnnssssennns 10 m Inserting the Remote Control Batteries na sensunanosennseesennnsessernns 10 u Gettin StSt 11 OPERATION m Selecting Auto Mode an saanaunerserannesesenneooesenassaerannesoenanseoeeennesoesensesoecans 12 m Selecting Cool Mode unneesnssssennnsssennnessesnnesssnsnnnsennnnsssssnnnsssennnssssennnsssnnnnsssssnnnnsenennn 13 m Selecting Heat Mode cssssssccsssssssssssescssssssccsssssscssssnescsssnscessssssccessnseecsssssesesssnssesstese 14 m Selecting Dry Mode een een 15 m Selecting Fan Mode cccsscsssssssccssssssssssssccsssssscssssscccsssnssesssssesesssnscsesssssecsssssscesstssesessons 16 m Selecting the Turbo Function sssssccsssssescsssssscsssssscssssnsecssssseecssssscssssnsssssssseecessens 16 m Selecting the Energy Saving Function ssssssssssscssssssecsssssssssssnsesessssssssssseecesseee 17 m Selecting good sleep Mode nnaaasanssenseeseensanassenssersessesannnnnsneseee 18 m Adjusting the Airflow Direction naaa caaananserseeennserseennnnsoseeennssssernnnss 20 m Selecting Auto Cleaning Function an seaannanseeennseessenneeseeunnesoesnnsessennns 21 m Setting the On Timer cecscsssssssccsssssscssssssccsssssecssssssccsssnscecsssssseessnscecsssssecsssnsscessessceessone 22 m Setting the Off Timer o cessssssssssssccssssssssssssssssscssssssseesssssnssscsssssssscsesssnsscces
15. ation of the indoor unit The silence function is set only in cool and heat mode 1 Press the On Off button Result The operation indicator on the indoor unit lights up Fiend The air conditioner starts up in the mode you selected last The indoor unit beeps 2 C2 4 A 2 Press the CS button DB B a CB By Pressing the button again the silence function is canceled Operating Your Air Conditioner Without the Remote Control You can operate your air conditioner directly without the remote control 1 To turn the air conditioner on press the ON OFF switch on the right side of the indoor unit Result The Operation indicator on the indoor unit lights up The indoor unit beeps The air conditioner starts up in the appropriate mode for the room temperature The air conditioner changes the Cool or Heat mode automatically depending on the current temperature during operation Room Temperature Operating Mode Lower than 75 F 24 C Heating Higher than 75 F 24 C Cooling 2 Toturn the air conditioner off press the On Off button again Evenif you turned the air conditioner on with the On Off button you can control it with the remote control Selecting mpizone Mode The mpizone mode creates strong purified zone by decomposing harmful particles in the behavior of active hydrogen H and oxygen ion O The mpizone mode can be selected whether the air conditioner is turned on or not cm
16. conditioner starts dehumidifying and the fan speed adjusts automatically O AF 4 To control the airflow direction refer to page 20 Selecting Fan Mode Fan Mode 4 Low Fan Speed 4 AR TS Select Fan mode if you want to ventilate your room It helps to refresh the air in your room You can adjust the fan speed in this mode 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps ode 2 Press the button on the remote control until Fan is displayed ode Result The indoor unit beeps each time you press the button The air conditioner runs in Fan mode The temperature is set automatically You can change modes at any time Fan Speed 3 Press the button to adjust the temperature until the required setting is displayed Low gt Medium gt High Result Each time you press the button the indoor unit beeps 4 To control the airflow direction refer to page 20 Selecting the Turbo Function Turbo Auto Turbo OE l R i 5 You can select the Turbo Function if you want to cool or heat your room as quickly as possible The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected 1 Press the On Off button Result The operation in
17. ction only in Cool mode 3 Press the button to adjust the temperature until the required temperature is displayed You can set the temperature between 79 F 26 C and 86 F 30 C If you want to adjust temperature under 79 F 26 C cancel the ee Energy saving function before adjusting the temperature Hr SYI 4 Press the to select the fan speed until the required setting is displayed Auto gt Low gt Medium gt High Fan Speed Result Each time you press the button the indoor unit beeps Speed 5 To control the airflow direction refer to page 20 CY CH Selecting good sleep Mode Cool 3 N Mode 4 good oS 1 1 Sleep A Lar t S t good Sleep S N j Set Temp I F Auto l zl ood D 1 1 HE A dar Cool Set Cancel al i Mn DLS good sleep mode helps users to fall asleep well after going to bed whether being too hot to sleep or being awakened by coldness The good sleep mode can be selected only when the air conditioner is switched on or off in cool heat mode 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps 2 Press the button to select cool or heat mode Result The indoor unit beeps each time you press the button The air conditioner runs in cool or heat mode ood 3
18. dicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps TURBO 2 Press the button Result The temperature and fan settings are adjusted automatically The air conditioner cools or heats the room as quickly as possible After 30 minutes the air conditioner is reset automatically to the previous setting You can select the Turbo function in Auto Cool and Heat mode If you select this function in Dry or Fan mode the mode changes to Auto mode 3 Pressthe button again to stop the Turbo Function before the end of the 30 minute period Result The air conditioner is reset automatically to the previous setting 4 To control the airflow direction refer to page 20 Selecting the Energy Saving Function You can select the Energy Saving Function to save energy when cooling The temperature range decreases in order to perform this function 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps 2 Press the 2 button Result The indoor unit beeps The air conditioner runs in the Energy saving function The outer airflow blade moves up and down The airflow direction indicator is displayed automatically To stop the Energy saving function press the gt again E Saver You can select the Energy saving fun
19. e careful of it when cleaning gt All of the manufacturing and packaging materials used for your new appliance are compatible with the environment and can be recycled Name of Each Part The design and shape can be changed according to the model Room Temperature sensor Power On Off button Airow blade outlet Air filter under the panel mpizone lt mpizone EEE mode indicator Timer good sleep ne Auto cleaning indicator mode indicator Set temperature amp Operation indicator room temperature Outdoor Unit AQVO9V Series AOV12V Series Air Inlet Rear Air Outlet Connection Valve Inside Outdoor Unit AQV18V Series AOQV24VX Series Air Inlet Rear Connection Valve Inside Remote Control Buttons and Display Airflow direction indicator Temperature setting Operating mode indicator Auto Cool Dry Fan Heat EEIT Turbo function indicator H Mpi Zone mode indicator uto Cogl pry Silence indicator o Hig anteater Fan speed indicator a Ta E T pa erilenceaa Energy saving indicator gg 1 ga Auto Remote control transmission indicator et ren Bi Off Timer indicator On Timer indicator V N m Temperature adjustment buttons Battery life indicator good sleep mode indicator Power On Off button Fan ans Mode selection button Auto Cool Dry Fan Heat
20. lected temperature 9 F the air conditioner stops heating but the fan is still operating The air conditioner starts heating provided that the room temperature is lower than the desired temperature selected temperature 5 F 4 Press the button to select the fan speed until the required setting is displayed Auto gt Low gt Medium gt High Result Each time you press the button the indoor unit beeps For the first 3 5 minutes the fan may not operate to prevent cool air from flowing out of the indoor unit This helps to warm the air in your room sufficiently 5 To control the airflow direction refer to page 20 Selecting Dry Mode Select Dry mode if you want to dehumidify your room You can adjust the temperature in this mode 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps 2 Press the button on the remote control until Dry is displayed Result The indoor unit beeps each time you press the button The air conditioner runs in the Dry mode You can change modes at any time 3 Press the button to adjust the temperature until the required temperature is displayed You can set the temperature between 66 F 18 C and 86 F 30 C Result Each time you press the button Set Temp The temperature adjusts by 1 F WTF The indoor unit beeps 12 The air
21. leep mode 1 Press the Set Cancel button on the remote control good sleep mode shuts off and the good sleep indicator will disappear Adjusting the Airflow Direction Adjust the airflow direction to circulate the air according to various needs By adjusting the airflow direction the efficiency of the air conditioner can be increased l Adjusting the Airflow Direction Vertically You can adjust the airflow direction vertically The outer airflow blade moves up and down to increase the efficiency of the cooling or heating operation 1 Press the CQ button until the required direction is set Result The outer blade is adjusted vertically 2 Press the CD button again to move the blade up and down automatically during operation 3 Press the CD button again to stop the blade moving up and down Note If you turn the air conditioner Then the blade Off is closed completely On set to the default position Adjusting the Airflow Direction Horizontally You can adjust airflow direction horizontally manually The inner blades with small fins move the air in the desired direction 1 Adjust the inner blades by moving them left or right Make sure do not touch the inner blades during operation It may cause injury on your fingers Selecting the Auto Cleaning Function Auto cleaning function offers inside air conditioner dry to prevent mold gr
22. m temperature is higher than the selected temperature the air conditioner starts cooling If the room temperature reaches the set temperature the air conditioner stops cooling but the fan continues to operate 4 Press the button to select the fan speed until the required setting is displayed Auto gt Low gt Medium gt High Result Each time you press the button the indoor unit beeps YY Fan Speed 2 5 To control the airflow direction refer to page 20 Selecting Heat Mode Heat Set Temp IF LIL Auto Fan Speed A N si You can select Heat mode if you want to heat your room You can adjust the temperature and the fan speed when heating 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps ode 2 Press the button on the remote control until Heat is displayed ode Result The indoor unit beeps each time you press the button The air conditioner runs in Heat mode You can change modes at any time 3 Press the button to adjust the temperature until the required temperature is displayed You can set the temperature between 61 F 16 C and 86 F 30 C Result Each time you press the button The temperature adjusts by 1 F The indoor unit beeps If the room temperature reaches the set temperature se
23. n operation 1 Press the C2 button Down 2 Press the A or buttons until 2 0 Hr is displayed Set Cancel 3 Press the CD button 4 Press the oO button Down 5 Press the Ap or buttons until 4 0 Hr is displayed Set Cancel 6 Press the 5 button If you would like to turn on the air conditioner and then to turn off it automatically at the appointed time by using On Off Timer during operation you should set the On Timer longer than the Off Timer Make sure that the air conditioner will not continue to run after On Timer setting is confirmed You can check or change the mode and or the temperature by pressing the button or the button after setting the Off Timer The most recently used function is set between On and Off Timer i Set Cancel CY 2 to turn on off the air conditioner and good sleep mode Off Timer of mpizone mode cannot be set out separately If you would like to turn off the air conditioner and then to turn on it again automatically at the appointed time by using On Off Timer during non operation you should set the Off Timer longer than the On Timer To Cancel the Off Timer 1 Set Cancel Press the C5 button to cancel the Off Timer Set Cancel If you press the C5 button both the On Timer and the Off Timer are canceled Set Cancel eS eS Selecting Silence Function Silence function makes the noise much quieter during the oper
24. nt panel and pull to release Front panel 4 Remove all dust on the air filter with a vacuum cleaner or brush a Body groove 5 When you finish insert the top of the filter into the slot and fix it to Body Air filter 5 tabs or 3 tabs of the grille 6 Clean the front panel with a damp cloth and mild detergent Front panel do NOT use benzene solvents or other chemicals 7 Reassemble the air filter and the front panel If you have not used the air conditioner for a while select the Fan mode for 3 to 4 hours to dry the inside of the air conditioner Cleaning Deodorizing and Bio filter Option To remove minute dust particles and odors deodorizing and Bio filter are installed in the air conditioner You should clean the filters every 3 months 1 Open the upper front grille by pulling the lower right and left tabs of the grille 2 Pull out the deodorizing and Bio filter Deodorizing Filter 3 Wash the filters with clean water then dry them in the shade 4 Insert the filters into the original position Bio Filter You can change the position of filters with each other F i ront pane 5 Close the front grille
25. owth This feature allows you to use the air conditioner more clean and fresh air ESnote Conii gt When the air conditioner is turned off Set Temp Auto The faj indicator on the indoor unit display appears and the Auto cleaning ULF function runs Auto VE When the air conditioner is turned on The a indicator on the indoor unit display appears and the Auto cleaning function runs after stopping the air conditioner operation Mode Operating time Auto cool Cool Dry 30 minutes Control Panel Auto heat Heat Fan 15 minutes Auto cleaning operating time varies according to the mode you selected before the air conditioner turned off The Auto Cleaning indicator appears only on the indoor unit display When the air conditioner is turned on the Auto cleaning function runs after stopping the air conditioner operation Setting the On Timer You can set the On Timer to turn on the air conditioner automatically at the appointed time within a range of 30 minutes to 24 hours 1 Press the button 5 OSa m gt C 2 Press the A or Cy buttons until the desired time is displayed to set Bell Te the On Timer You can set the time between 0 5 hour and 24 hours t t 3 Press the amp button to complete the setting Result The remaining time is displayed Sn The timer indicator stops blinking On dur The selected mode and the temperature on the display disappear after 10 seconds
26. pizone 1 Press the ee button Auto The air conditioner starts up in mpizone Auto mode automatically The mpizone mode also runs when the air conditioner is turned on By pressing the Br button again the mpizone mode is canceled ey r mpizone On Off E SE 2 Pressthe RER to select the mpizone operation types Whenever press the an button Auto Silence and Rapid will appear Er repeatedly Auto Controls the fan speed automatically Silence Purifies the indoor air with silence Rapid Purifies the indoor air quickly N N r mpizone Clean Mode C C C Ifmpizone mode is turned on when the air conditioner runs You cannot select the mpizone operation types by pressing the Calis button The mpizone mode runs only in Auto The mpizone mode will also stop by pressing the Power button of the panel mpi Micro Plasma lon Cleaning Air Filter on Your Air Conditioner For the best use of your air conditioner you must clean it every 2 weeks regularly to remove the dust that accumulates on the air filter CAUTION Before cleaning your air conditioner ensure that you have switched off the breaker used for the unit 1 Open the front panel by pulling tabs on the lower right and left sides of the indoor unit 2 Detach the front panel by pulling it forwards 3 Hold the edge of the air filter under the fro
27. rature and air current change according to the three stages Falling asleep Sound sleep and Waking up from good sleep mode and then the air conditioner will automatically turn off when the set time has elapsed Three stage good sleep prevents you from having difficulty sleeping on extremely hot cold nights Falling Asleep Eases you into sleep by dropping the temperature Sound Sleep Relaxes your body and raises your temperature slightly Wake Up Allows you to wake up to comfortable crisp air making you feel refreshed and energized e Set the Off timer in good sleep mode for more than 5 hours Sleep may be disturbed if the good sleep mode is set for too short or too long a time because the temperature changes are set to an 8 hour cycle e If the good sleep mode is set for less than 4 hours the operation will stop at the set time If the good sleep mode is set for over 5 hours the last hour will run in Waking Up stage before shut ting off Recommended set temperature is between 77 F 81 F 25 C 27 C for cooling and 70 F 73 F 21 C 23 C for heating Temp 4 F 2C 2 PIG Set temperature 2 FETO When the 8 hour cycle completes this section repeats 4 F20 1 2 3 4 5 6 7 8 Time hr Temp Eo When the 8 hour cycle eee completes this section ZFC repeats Set temperature 2 F10 4 F20 I I l l l 1 2 3 4 9 6 7 8 Time hr To deactivate good s
28. rked the chemical symbols Hg Cd or Pb indicate that the battery contains mercury cadmium or lead above the reference levels in EC Directive 2006 66 If batteries are not oroperly disposed of these substances can cause harm to human health or the environment To protect natural resources and to promote material reuse please separate batteries from other types of waste and recycle them through your local free battery return system Getting Started e soe ee ee ee Tee The User s Manual provides you with valuable information about your air conditioner In order to take full advantage of the air conditioner s features please read this manual carefully before using You have already seen the basic description of the unit on pages from 8 to 10 Starting with the next page you will find a series of step by step procedures for each function available The illustrations in the step by step procedures use three different symbols A PRESS PUSH HOLD DOWN Selecting Auto Mode Auto Mode 4 Set Temp AF IL You can select Auto mode if you want to cool or heat your room automatically You can adjust the temperature in this mode 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps 2 Press the button on the remote control until Auto is displayed Result
29. ssnsssesessesees 23 m Selecting Silence Function aa aaaanneooeennseeeennanseeennneessenneeseennneesennnanseernns 24 m Operating Your Air Conditioner Without the Remote Control une 24 m Selecting mpizone Mode o ccccsssssssssssssssssssssssssssscsessesssssssssssnsssssssssnssessssesceeeeessesees 25 RECOMMENDATIONS FOR USE m Cleaning the Air Filter on Your Air Conditioner sssssssssssssssssesssssssssecesseesseeess 26 m Keeping Filters clean u a 26 m Temperature and Humidity Ranges csscsssssscssssssecsssssecsssssessssssseesssssessesssssecessees 27 m Operating Recommendations sssccssssssccsssssecssssssscsssnscessssseccssssscesssssecsesssssecessees 28 m Solving Common Problems cessssssssssscsssssesssssssscsssnsccssssseccsssnscesssssecssssssscesssssecessees 29 Register your product at www samsung com global register Safety Precautions The following safety precautions are provided to protect the users safety and prevent property damage Make sure to read the followings and use the air conditioner properly D Keep this user s manual together with the installation manual in a handy place so that you can find it whenever you need to see it after reading this manual thoroughly N WARNING This indicates the possibility of serious injury or death AN CAUTION Thisindicates the possibility of serious injury or damage to environments when operated incorrectly WHEN INSTALLING