1. 1 Push the lever as arrow 2 Insert two AAA batteries 3 Close the cover by place it back to its indicates on the rear side of the Check and match the 4 and original position remote controller and pull up signs accordingly Make sure you You should hear click sound when the cover is have inserted the batteries in locked properly correct position lt The signal may not be received well of electronic lighting style fluorescent lamps such as inverter fluorescent lamps note arein the same space If other electrical products operate by the remote controller call your nearest contact center 9 Brazil AQV amp ASVO9PG BIM 32441A E indd 9 e 2011 6 18 Brazil AQV amp ASVO9PG BIM 32441A E indd 10 e 2011 6 18 11 11 08 Basic function Basic operation is an operation mode that can be selected by pressing the Mode button Auto In Auto mode the air conditioner will automatically set the temperature and fan speed depending on the room temperature detected by the room temperature Cool In Cool mode the air conditioner will cool your room You can adjust the temperature and the fan speed to feel cooler in hot season If current outside temperatures are much higher than the selected indoor temperature it may take time to bring the inner temperature to the desired coolness lt Quiet mode e amp pf lt makes the noise quieter during operating the indoor unit in the
2. Compressor will immediately start provided 3 minutes have elapsed since the last stop gt After 2 minutes of operation shut the suction valve with the same wrench Turn the system off and switch mains supply off Disconnect tubing After disconnection protect valves and tubing ends from dust Compressor damage may occur if run at a negative suction pressure 39 Brazil AQV amp ASVO9PG BIM 32441A E indd 39 e 2011 6 18 11 11 50 Fixing the indoor unit in place Perform the following work on the area where gas leak test was done priorly After checking for gas leaks in the system insulate the pipe hose and cables Insulation Then place the indoor unit on the installation plate 1 Toavoid condensation problems wrap foam insulation as shown in the figure on 09 a part without insulation on the end of the pipes 2 Windthe pipe assembly cable and drain hose with vinyl tape Pipes 3 Placethe bundle the pipe assembly cable and drain hose in the lower part ofthe indoor unit carefully so it does not project from the rear of the indoor unit Installation plate 4 Hookthe indoor unitto the installation plate and move the unit to the right Vinyl tape and left until it is securely in place Connecting wires 4 lt Make sure pipe does not move when you install the indoor unit on Drain hose _ a installation plate 5 Wrap the rest of the pipe with vinyl ta
3. The manufacturer shall not be responsible for damages arising from the use of non compliant units The air conditioner is compliant with the requirements of the Low Voltage Directive 72 23 EEC the EMC Directive 89 336 EEC and the Directive on pressurized equipment 97 23 EEC The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and requirements set forth in the Operating limits table included in the manual shall immediately invalidate the warranty The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry Do not use the units if damaged If problems occur switch the unit off and disconnect it from the power supply In order to prevent electric shocks fires or injuries always stop the unit disable the protection switch and contact SAMSUNG technical support if the unit produces smoke if the power cable is hot or damaged or if the unit is very noisy Always remember to inspect the unit electric connections refrigerant tubes and protections regularly These operations should be performed by qualified personnel only The unit contains moving parts which should always be kept out of the reach of children Do not attempt to repair move alter or reinstall the unit If performed by unauthorized personnel these operations may cause electric sho
4. 18 2494 30 15 600mm minimum Make at least one round It will reduce noise and vibration The appearance ofthe unit may be different from the diagram depending on the model 26 Brazil AQV amp ASVO9PG BIM 32441A E indd 26 e 2011 6 18 11 11 27 Space Requirements for Outdoor Unit When installing 1 outdoor unit Figure Description 5 a Top view Side view a m T Air intake Air outlet 4 Air intake Air outlet v e Air flow direction Unit mm When the air outlet is opposite the When the air outlet is towards the When 3 sides of the outdoor unit are wall wall blocked by the wall v o D S Ti EPFL 58 g E 0 o c8 n 150 600 or more The upper part of the outdoorunit The upper part of the outdoor unit When the walls are blocking front and the air outlet is towards the wall and the air outlet is opposite the and the rear side of the outdoor unit wall 300 ormore REESE F 2000 or more 5 5 1 8 16 D N a 0 182 When installing more than 1 outdoor unit Unit mm When the air outlet is towards the wall When 3 sides ofthe outdoor unit are blocked by the wall U U U i 2 i z 9 v 5 0 0 0 o t8 7777777777 777777777777 U 0 0 E gt as t 300 or more 600 600ormore 600 or more 27 Brazil AQV amp ASV
5. 2 refrigerant pipes of different diameters The smaller one is for the liquid refrigerant The larger one is for the gas refrigerant A short pipe is already fitted to the air conditioner You may need to extend the pipe using the assembly pipe optional in The connection procedure for the refrigerant pipe varies J according to the exit position of the pipe when facing the wall Right A 48 Left B ET lt Underside C Rear 1 Cut out the appropriate knock out piece A B C on the rear of the indoor Outer DEE Torque kgf cm unit unless you connect the pipe directly from the rear 26 35 mm 140 170 2 Smooth the cut edges 09 52 mm 250 280 012 70 mm 380 420 3 Removethe protection caps of the pipes and connect the assembly pipe 015 88 mm 440 480 to each pipe Tighten the nuts first with your hands and then with a 019 05 mm 990 1210 torque wrench applying the following torque 02223 mm 990 1210 B lt Ifyou want to shorten or extend the pipes refer to page 33 34 NOTE 4 Cutoffthe remaining foam insulation 5 If necessary bend the pipe to fit along the bottom of the indoor unit Then pull it out through the appropriate hole The pipe should not project from the rear of the indoor unit gt The bending radius should be 100 mm or more 6 Passthe pipe through the hole in the wall 7 Forfur
6. 6225 www samsung com GUATEMALA 1 800 299 0013 www samsung com HONDURAS 800 27919267 www samsung com JAMAICA 1 800 234 7267 www samsung com NICARAGUA 00 1800 5077267 www samsung com PANAMA 800 7267 www samsung com PERU 0 800 777 08 www samsung com PUERTO RICO 1 800 682 3180 www samsung com TRINIDAD amp TOBAGO 1 800 SAMSUNG 726 7864 www samsung com VENEZUELA 0 800 100 5303 www samsung com Brazil_AQV amp ASVO9P _IBIM_32441A_E indd 44 e 2011 6 18 1 11 58 AQVO9P Series ASVO9P Series AQV12P Series ASV12P Series AQV18P ex Series ASV18P Series AQNV24P Series ASV24P Series 10096 Recycled Paper imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung con register P DB98 32441A 1 en Brazil_AQV amp ASVO9P _IBIM_32441A_E indd 45 2011 6 18 11 11 54
7. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug There may be internal damage if moisture is left in components 2 Before using the air conditioner again dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours This helps remove odors which may have generated from dampness Periodical checks Refer to the following chart to maintain the air conditioner properly HSITDNA ee Every 2 Every 3 Every 4 Type Description Weeks months months Once a year Clean the air filter 1 Clean the condensate drain 2 e Indoor anf Thoroughly clean the heat exchanger 2 e Clean the condensate drain pipe 2 e Replace the remote controller batteries 1 e Clean the heat exchanger on the outside of the unit 2 e e Clean the heat exchanger on the inside of the unit 2 e Clean the electric components with jets of air 2 Outdoor Verify that all the electric components are firmly e unit tightened 2 Clean the fan 2 e Verify that all the fan assembly is firmly tightened 2 e Clean the condensate drain pan 2 e 6 This check mark requires checking the indoor outdoor unit periodically following to the description to maintain the air conditioner properly 1 The described operations should be performed more frequently if the area of installation is very dusty NOTE 2 These operati
8. a torque wrench I Liquid pipe side applying the following torque N B Excessive torque can be cause of gas leakage Outer Diameter Torque kgfecm NOTE 26 35 mm 140 170 09 52 250 280 lt Make the electrical connection and leave the system into stand by 012 70 mm 380 420 mode Do not turn on the system 015 88 mm 440 480 This is necessary for better vacuum operation full OPEN position of 019 05 mm 990 1210 Electronic Expansion Valve EEV 022 23 mm 990 1210 36 3 Connectthe charging hose of the low pressure side of manifold gauge to a Manifold gauge gas service port as seen in the picture 4 Openthe valve of the low pressure side of manifold gauge counterclockwise Valve 5 Purgethe air in the connected pipes using the vacuum pump for about Gas service port 15 minutes P lt Low pressure gt gt Make sure that pressure gauge shows 0 1MPa 76cmHg after about 10 minutes This procedure is very important to avoid a gas leak Close the valve of the low pressure side of manifold gauge clockwise Turn offthe vacuum pump gt Check for 2 minutes if there is any pressure change Liquid service port High pressure Remove the hose of the low pressure side of manifold gauge 6 Setavalve cork of liquid and gas service port to the open position 7 Mountthe valve stem nuts and the service port cap to the valve and tighten them at the torque of 183kgf cm with a torque wrench 8 Ch
9. depending on the models 19 2011 6 18 11 11 21 109 Cleaning the air conditioner Removing the Air filter Grab the handle and lift it up Then pull the Air filter towards you and slide it down I Cleaning the air filter Washable foam based air filter captures large particles from the air The filter is cleaned with a vacuum or by hand washing Open the panel and put the Air filter out Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy rinse it with running water Insert the Air filter back in its original position Dry the Air filter in a ventilated area and close the front panel Clean the Air filter every 2 weeks or when the filter clean reminder lights up Cleaning term may differ depending note onthe usage and environmental conditions In dusty area clean it once a week Ifyou turn off the air conditioner by pressing Power 5 button the filter clean reminder will be turned off Ifthe Air filter dries in a confined or humid area odors may generate If it occurs re clean and dry it in a well ventilated area 20 Brazil_AQV amp ASVO9P _IBIM_32441A_E indd 20 e 2011 6 18 11 11 28 Maintaining the air conditioner If the air conditioner will not be used for an extended period of time dry the air conditioner to maintain it in best condition 1
10. finder to find out locations of the studs attached to the window frame 2 Fix the plate hanger on two studs 2 Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit 3 Attach the installation plate to the wooden upright using tapping screws Search for other spots if there are less than two studs or the distance between the studs are different from the cmumou Plate hanger lt Fix the installation plate without inclining to one side lt Make sure that a wall can withstand the weight of the product If you install the product in a place where it is not warning Strong enough to withstand the product weight the unit could fall and cause injury Connecting the assembly cable e I Cable specification Model Power cable Interconnection cable GL 32 3 09 123 3G 1 5mm HO7RN F 4G 1 5mm HO7RN F 20A 18 24 3G 2 5mm HO7RN F 36 15mm 25A 2G 0 75mm HOSRN F lt Connect the power cable to the auxiliary circuit breaker If every pole fails to connect to Note the power supply it must be incorporated in a wire with a contact opening of 23mm I Connecting the cable KA 3 When you install the unit make first refrigerant connections and then electrical connections Connect the air conditioner to grounding system before performing the electrical connection If unit is uninstalled first disconnect electrical cabl
11. flare nuts are attached to the end of each pipe of an evaporator or a service port note Use the nuts when connecting the pipes lt The 2 3 4 wire assembly cable is optional If it is not supplied use the standard cable lt The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below 28 Brazil AQV amp ASVO9PG BIM 32441A E indd 28 e 2011 6 18 vette Brazil AQV amp ASVO9PG BIM 32441A E indd 29 e I Optional accessories The following connection accessories are optional If they are not supplied you should obtain them before installing the air e HSITDNA conditioner ae estem tem meee gripes Pring Q635mm 1 09 12 18x RIX nsulatoh 1 AQVex aQ Q Q Rubber Legs 4 Pipe Clamps A 3 Pipe Clamps 3 Cement Nails 6 ie b Putty 100g 1 w 2 B If these accessories are supplied they will be in the accessory box NOTE Tools required for installation General Tools e Vacuum Pump Backward flowing prevention Manifold Gauge Stud Finder Torque Wrench Pipe Cutter Reamer Pipe Bender Spirit Level Screw Driver Spanner Drill L Wrench Measuring Tape Tools for test operations Thermometer e Resistance Meter Electroscope Fixing the installation plate You can select the direction of the drain hose depending on wh
12. lines gt Always verify that the cut off and protection switches are suitably dimensioned Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram included in the manual gt Always verify that electric connections cable entry section of leads protections are compliant with the electric specifications and with the instructions provided in the wiring scheme Always verify that all connections comply with the standards applicable to the installation of air conditioners Choosing the installation location Indoor unit gt Where airflow is not blocked Where cool air can be distributed throughout the room Install the refrigerant piping length and the height difference of both indoor and outdoor units as indicated in the installation diagram Wall that prevents vibration and is strong enough to hold the product weight Out ofthe direct sunlight 1m or more away from the TV or radio to prevent the screen from being distorted or noise from being generated As far away as possible from the fluorescent and incandescent lights so that the remote controller can be operated well A place where the air filter can be replaced easily vv www 25 Brazil AQV amp ASVO9PG BIM 32441A E indd 25 e 2011 6 18 11 11 24 10 Choosing the installation location Outdoor Unit Where it is not exposed to strong wind Well ventilated an
13. sk gf Auto Cool e af Auto Sk Low ea Med High Dry e af Auto Fan OSH Low gg Med cf ali High Heat Model AQV eff a Auto ef Low eff Med Segal High Press the ew button to adjust the temperature Auto You can adjust the desired temperature by 1 C within the range of 16 C 30 C Cool You can adjust the desired temperature by 1 C within the range of 16 C 30 C Dry You can adjust the desired temperature by 1 C within the range of 18 C 30 C Fan Temperature adjustment is not possible Heat Model AQV gt k You can adjust the desired temperature by 1 C within the range of 16 C 30 C NOTE lt Air flow can be adjusted manually see page 12 for instructions Brazil AQV amp ASVO9PQG IBIM 32441A E indd 11 e 11 2011 6 18 sao TE Adjusting the air flow direction Air flow can be directed to your desired position Vertical air flow Air flow blades move up and down Press the Air swing button on the remote controller gt Air swing indicator will be on and air flow blades move up and down continuously to circulate the air gt Press the Air swing button on the remote controller again to keep the air flow direction in a constant position Auto st 8 Li Lt Horizontal air flow Make sure one of the blade pin lever
14. the standard fuse gt Failing to do so may result in electric shock fire problems with the product or injury FOR USING NCAUTION Do not place objects or devices under the indoor unit gt Water dripping from the indoor unit may result in fire or property damage Check that the installation frame of the outdoor unit is not broken at least once a year gt Failing to do so may result in injury death or property damage Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency Do not stand on top of the appliance or place objects such as laundry lighted candles lighted cigarettes dishes chemicals metal objects etc on the appliance gt This may result in electric shock fire problems with the product or injury Do not operate the appliance with wet hands gt This may result in electric shock Do not spray volatile material such as insecticide onto the surface of the appliance gt As well as being harmful to humans it may also result in electric shock fire or problems with the product Do not drink the water from the air conditioner gt The water may be harmful to humans Do not apply a strong impact to the remote controller and do not disassemble the remote controller Do not touch the pipes connected with the product gt This may result in burns or injury Do not use this air conditioner to preserve precision equi
15. you into sleep by dropping the temperature Sound sleep Relaxes your body and raises your temperature slightly Wake up from good sleep mode Allows you to wake up from comfortable intermittent air and it makes you feel refreshed Set Off timer in good sleep mode over 5 hours You fell disturbed sleep if the good sleep is set too short or long note because the default is set to 8 hour operation lt Ifthe good sleep mode is set less than 4 hours the operation will stop at the same time Ifthe good sleep mode is set over 5 hours it will run as Wake up stage from the last one hour before it stops lt Recommended set temperature is between 25 C 27 C for cooling 13 Brazil AQV amp ASVO9PG BIM 32441A E indd 13 e 2011 6 18 11 11 14 Setting the On Off timer You can set the air conditioner to turn on off automatically at desired time Setting On timer while the air conditioner is off Off timer while the air conditioner is on Setting On timer Temp Fan E d light 1 Auto Temp good Clean Humi sleep Filter Reset Beep Off Display Off On Off Set NE Cancel Setting Off timer ei Temp Fan d light 4 Auto Temp good Clean Humi sleep Filter Reset Off Display Off On off Set Timer Time y ancel Auto SET 14 1 Pressthe On Timer Off Timer button On Off timer indicator will blink on
16. Cool mode Dry The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air Dry mode makes the air feel refreshing in a humid climate To maximize the dehumidification capacity during the Dry operation the air conditioner could be operating at lower or higher temperature than the remote controller set temperature Fan Fan mode can be selected to ventilate your room Fan mode will be helpful to refresh the stale air in your room Heat Model AQV The air conditioner heats as well as cools Warm your room with this versatile appliance in the cold of winter Fan may not operate for about 3 5 minutes at the beginning to prevent any cold blasts while the air conditioner is warming up Quiet mode e amp lt P makes the noise quieter during operating the indoor unit in the Heat mode Sincethe air conditioner heats the room by taking heat energy from outdoor air the heating capacity may decrease when outdoor temperature is extremely low Use an additional heating appliance in combination with the air conditioner if you feel the air conditioner heats insufficiently 10 Press the button to turn on the air conditioner Press the button to set the operating mode Each time you press the Mode button the mode will change in order of Auto Cool Dry Fan and Heat Model AQV HSITDNA Press the button to set the desired fan speed Auto
17. HSITDNA Brazil_AQV amp ASVO9P _IBIM_32441A_E indd 1 e 2011 6 18 a TE Features of your new air conditioner Contents Cool Summer Offer USING PARTS On those hot sweltering summer days and long restless Safety precautions nights there is no better escape from the heat than the Checking before use cool comforts of home Your new air conditioner brings an Checking the name of the parts 7 end to exhausting hot summer days and lets you rest Beat Checking the remote controller 8 the heat with your own air conditioner this summer es 0 Adjusting the air flow direction 2 Cost Efficient System Using the Turbo function 2 good sleep mode 3 Your new air conditioner not only provides maximum Setting the On Off timer 4 cooling power in the summer but also can be an efficient Using the Smart Saver function 6 heating method in the winter with the advanced Heat Using the SPi function 7 pump system Heat pump system is 3 times more Using the Quiet function 7 efficient compare to the other electrical heating appliance Using the Auto Clean function 8 so you can further reduce its running cost Now meet year Cleaning the air conditioner 9 round needs with one air conditioner Maintaining the air conditioner 1 Troubleshooting Lookfor Everywhere The elegant and harmonious design gives priority to the esthetics of your spac
18. O9PG BIM 32441A E indd 27 e 2011 6 18 10 Choosing the installation location When the walls are blocking front and the rear side of the outdoor When the upper part of the outdoor unit and units the air outlet is opposite the wall a s 8 9 5 o 300 or more 600 or Hi 300 or more E Ormore 500 or more more 1500 or 600 or more When front and rear side of the outdoor unit is towards the wall Up k LL J h h 1500 or 600 or 3000 or 3000 or 200 or more more more more more 500 or more f installation is done in inappropriate space unit may generate sound and cause bad effect on the product caution Installation must be done in level and in a place where vibration will not cause any effect Accessories The following accessories are supplied with the air conditioner B The number of each accessory is indicated in parentheses NOTE Accessories in the indoor unit case Installation Plate 1 Remote Batteries for User s amp Installation controller 1 Remote controller 2 Manual 1 Accessories in the outdoor unit case 4 wire 2 wire 3 wire Drain Plug 1 Assembly Cable 1 Assembly Cable 1 Assembly Cable 1 Rubber Leg 4 309 123 18 24 18 24 soe Bap The
19. UTION 0 This appliance should be positioned in such a way that it is accessible to the power plug gt Failing to do so may result in electric shock or fire due to electric leakage Install your appliance on a level and hard floor that can support its weight gt Failing to do so may result in abnormal vibrations noise or problems with the product Install the draining hose properly so that water is drained correctly gt Failing to do so may result in water overflowing and property damage When installing the outdoor unit make sure to connect the draining hose so that draining is performed correctly The water generated during the heating operation by the outdoor unit may overflow and result in property damage In particular in winter if a block of ice falls it may result in injury death or property damage Brazil AQV amp ASVO9PG BIM 32441A E indd 3 e 2011 6 18 11 11 01 Safety precautions FORPOWERSUPPLY fA WARNING 0 Remove all foreign substances such as dust or water from the power plug terminals and contact points using a dry cloth ona regular basis gt Unplug the power plug and clean it with a dry cloth gt Failing to do so may result in electric shock or fire Plug the power plug into the wall socket in the right direction so that the cord runs towards the floor b Ifyou plug the power plug into the socket in the opposite direction the electric wires within the cable may be damaged and his may result i
20. When cleaning the internal filter refer to the descriptions in the Cleaning the air conditioner section gt Failure to do may result in damage electric shock or fire Brazil_AQV amp ASVO9P _IBIM_32441A_E indd 5 e 2011 6 18 TE 5 TE Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within Refer to the table for efficient use Indoor Outdoor tem Mode Indoor humidity Remark Cooling 16 C 32 C E RE gs Relative humidity 8096 or less m Heating 27 Corless 7 Dry 18 C 32 C gt If the air conditioner operates in cooling mode for long period of time in high humidity area dew be formed gt If the outdoor temperature goes down to 5 C heating capacity may decrease as much as 60 70 of specified capacity according to the using conditions Model Maintaining your air conditioner Internal protections via the unit control system This internal protection operates if an internal fault occurs in the air conditioner Type Description Against cold air The internal fan will be off to against cold air when the heat pump is heating De ice cycle The internal fan will be off to against cold air when the heat pump is heating Anti protection of The compressor will be off to protect internal battery when the air condi
21. ayed on the remote controller and you can change the functions on the remote controller as listed below Auto Clean gt Filter Reset Temp Humi Beep Off good sleep gt Display Off function If you select the function under the button while the function of the button is switched by 2 4F button the 2 F function is canceled 8 Brazil AQV amp ASVO9PG 32441A E indd 8 e 2011 6 18 11 11 08 109 Remote controller display Quiet indicator Turbo indicator SPi indicator Smart Saver indicator d light Cool indicator 2 indicator Operation mode indicator Low battery indicator Transmit indicator HSI 15N3 Air swing indicator Fan speed indicator of all Auto Turbo Set temperature indicator On Timer indicator Off Timer indicator Ha NUS a good sleep indicador efl High X As to ASV Series don t operate the air conditioner when the remote controller is set to Heat mode Heat mode can be selected Series Battery changing time When the battery is exhausted 24 will be displayed in the remote controller display When the icon appears change the batteries The remote controller requires two 1 5V AAA type batteries Storing the remote controller When you do not use the remote controller for long time remove the batteries from the remote controller and store it Inserting the batteries
22. cks or fires Do not place containers with liquids or other objects on the unit All the materials used for the manufacture and packaging of the air conditioner are recyclable The packing material and exhaust batteries of the remote controller optional must be disposed of in accordance with current laws The air conditioner contains a refrigerant that has to be disposed of as special waste At the end of its life cycle the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely Brazil AQV amp ASVO9PQG 32441A E indd 24 e 2011 6 18 11 11 24 Installing the unit IMPORTANT When installing the unit always remember to connect first the refrigerant tubes then the electrical lines Always disassemble the electric lines before the refrigerant tubes gt Upon receipt inspect the product to verify that it has not been damaged during transport If the product appears damaged DO NOT INSTALL it and immediately report the damage to the carrier or retailer if the installer or the authorized technician has collected the material from the retailer HSITDNA gt After completing the installation always carry out a functional test and provide the instructions on how to operate the air conditioner to the user gt Donotuse the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occur
23. comes from fluorescent bulbs or neon signs may interrupt the electric waves Timer function does not set Check if you press the Set button on the remote controller after you have set the time The indicator is blinking continuously Press the Power D button or disconnect the power plug switch off the auxiliary power switch If the indicator is still blinking contact the service center Odors permeate in the room during operation Check if the appliance is running in a smoky area Ventilate the room or operate the air conditioner in Fan mode for 1 2 hours We do not use smelly components in the air conditioner 22 2011 6 18 11 11 28 PROBLEM SOLUTION Error is indicated Whenan indoor unit indicator blinks contact the nearest service center Noise is generated Depending on the status ofthe air conditioner usage noise can be heard when refrigerant flow movement changes It is normal HSITDNA Smoke is generated from the outdoor unit If may not be a fire but it can be a steam generated by the defrost operation from outdoor heat exchanger during Heat mode Model in winter Water is dropping from the outdoor unit piping connection Water may be generated because of the temperature difference It is normal 23 Brazil AQV amp ASVO9PG BIM 32441A E indd 23 e 2011 6 18 11 11 28 INSTALLATION PARTS x In this manual you may find
24. d cold air blown into conditioned space Model AQV 3 Pressthe Air swing button and check the following gt The airflow blades work properly 4 Press the Power button to stop the operation When you complete the installation successfully hand over this manual to the user for storage in a handy and safe NOTE place Pump down procedure when removing the product 1 Turn on the air conditioner and select Cool mode to run the compressor for 3 minutes 2 Release the valve caps on High and Low pressure side 3 UseL wrench to close the valve on the high pressure side 4 Approximately 2 minutes after close the valve on the low pressure side 5 Stopoperation of the air conditioner 6 Disconnect the pipes 41 Brazil AQV amp ASVO9PQG IBIM 32441A E indd 41 e 2011 6 18 1 112 How to connect your extended power cables Items to prepare compressor and insulation tape should be prepared by an installation technician Tools Crimping plier Connection sleeve mm Insulation tape Contraction tube mm Spec MH 14 20x 7 0 HxOD Width 18mm 50x 8 0 LxOD Shape 1 As shown in the figure peel off the shields from the rubber wire Unit mm of the power cable Power cable provided by us Peel off 20 mm of the wire shields of the tube installed already A lt After peeling off the tube wire you must insert a contraction tube CAUTION 120 180 Wire tube
25. d dustless places Out ofthe direct sunlight and rain Where neighbors are not annoyed by operation sound or hot air Solid wall or support that prevents vibration and is strong enough to hold the product weight Where there is no risk of flammable gas leakage When installing the unit at a high place be sure to fix the unit legs 3m or more away from the TV or radio to prevent the screen from being distorted or noise from being generated Install the unit horizontally Place where drained water does not become any problem Place with no plants especially climbing plants and where small animal can not access ww Vw F Avoid the following places to prevent malfunction of the unit Where there is machine oil Salty environment such as seaside areas Where sulfide gas exists Other special atmosphere areas Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner or more or more 125mm it i j 125 b Wrap the refrigerant pipes and the drain hose with the absorbent pad and vinyl tape Refer to page 40 for further details draining left or right L maximum pipe length and3 m as minimum pipe length CAUTION It will reduce noise and vibration H meters maximum total pipe length L meters maximum 600mm total pipe length minimum Model L 09 12 20
26. e D Changing direction of the drain hose Change the direction only when it is necessary 1 2 3 Detach the rubber cap with the plier scele Detach the drain hose by pulling it and turning to the left Insert the drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan Attach the rubber cap with a screwdriver by turning it to the right until it fixes to the end of the groove Check for leakage on both side of the drain outlet Pour the water in direction of arrow Direction of the drained water 35 Brazil AQV amp ASVO9PG BIM 32441A E indd 35 e 2011 6 18 Brazil AQV amp ASVO9PG BIM 32441A E indd 36 e 2011 6 18 11 11 48 Installing and connecting the drain hose of the outdoor unit Model While heating ice may accumulate During the process of defrosting check if condensation draining is adequate For adequate draining do the following 1 Insertthe drain plug into the drain hole on the underside of the outdoor unit lt Toavoid drain plug from contacting the ground secure gap between the Drain hole Ew ground and the bottom surface of the outdoor unit Drain plug CAUTION Bottom surface of outdoor Drain hole m Drain plug Drain hose Snow proof hood 2 Connect a drain hose to the drain plug 3 Ensure that condensation draining is adequate In area
27. e and complements any INSTALLATION PARTS of your existing interior d cor With its soft color and rounded edge shape the new air conditioner adds class Safety precautions to any room Enjoy what your air conditioner offers both Choosing the installation location e functionally and esthetically Accessories Fixing the installation plate 7 a Connecting the assembly cable 30 good sleep function nstalling and connecting the assembly pipe of the indoor unit 132 good sleep function allows you to set a comfortable sleep temperature while saving energy and having sound sleep Cutting or extending the pipe nstalling and connecting the SPi 5 ion functi drain hose of the indoor unit 34 1 Super plasma function Changing direction of the drain hose 35 SPi function generates hydrogen H and oxygen O to nstalling and connecting the attack undesirable air contaminants such as bacteria Purging the connected pipes pollen and odor It makes you breathe better as if you are Performing the gas leak tests staying around waterfalls ocean surf rivers and mountains Fixing the indoor unit in place Fixing the outdoor unit in place Final check and trial operation Pump down procedure when removing the product How to connect your extended power cables Brazi
28. e the obstacle away If you want to operate the air conditioner in the sunlight cover the outdoor unit using curtains or etc Check if the air conditioner is operating in De ice mode When the ice formed in winter or the outdoor temperature is too low the air conditioner operates in De ice mode automatically In De ice mode indoor fan stops and cool air does not come out If the doors or windows are open it may cause bad cooling heating Model performance Close the doors and windows Check if the air conditioner has just been turned on after stopping cooling heating Model AQV operation In this case just a fan will run to protect the outdoor unit compressor Check if the pipe length is too long When the pipe length exceeds maximum allowable pipe length cooling heating Model AQV k performance may decrease Air flow adjustment is not working Check if you have selected Auto Dry good sleep mode In these modes desired temperature is set to auto and you cannot adjust the temperature Fan speed adjustment is not working Check if you have selected Auto Dry Turbo good sleep mode In these mode fan speed is set to Auto and you cannot adjust the fan speed Remote controller is not working Check if your batteries are depleted Make sure nothing is blocking your remote controller sensor Check that there are strong lighting apparatus near the air conditioner Strong light which
29. e voltage frequency rated current condition is different it may cause fire The installation of this appliance must be performed by a qualified technician or service company e gt Failing to do so may result in electric shock fire explosion problems with the product or injury Install a switch and circuit breaker dedicated to the air conditioner gt Failing to do so may result in electric shock or fire Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed gt Failing to do so may result in electric shock or fire Do not install this appliance near a heater inflammable material Do not install this appliance in a humid oily dusty location in a location exposed to direct sunlight and water rain drops Do not install this appliance in a location where gas may leak gt This may result in electric shock or fire Never install the outdoor unit in a location such as on a high external wall where it could fall gt Ifthe outdoor unit falls it may result in injury death or property damage d5 This appliance must be properly grounded Do not ground the appliance to a gas pipe plastic water pipe or telephone line gt Failure to do so may result in electric shock fire an explosion or other problems with the product gt Never plug the power cord into a socket that is not grounded correctly and make sure that it is in accordance with local and national codes FOR INSTALLATION NCA
30. eckfora gas leak paying particular attention to the 3 way valve s stem nuts and to the service port cap Refer to page 39 Adding Refrigerant Add refrigerant charge according to table below If you use a pipe longer than 7 5m 15 g of refrigerant R410A must be added for each extra meter If you use a pipe shorter than 7 5m The purge time is normal Refer to the Service Manual for further details HSITDNA Vacuum Pump Backward flowing prevention liquid lt The remaining air in the Refrigeration cycle which contains moisture may cause malfunction on the compressor caution Always contact the service center or a professional installation agency for product installation Brazil_AQV amp ASVO9P _IBIM_32441A_E indd 37 e 37 2011 6 18 11 11 49 Purging the connected pipes Important information regulation regarding the refrigerant used This product contains fluorinated greenhouse gases covered by the Kyoto Refrigerant type GWP value Protocol Do not vent gases into the atmosphere R410A 1975 3 GWP Global Warming Potential 1 Please fill in with indelible ink gt D the factory refrigerant charge of the product Contains fluorinated greenhouse gases gt the additional refrigerant amount charged in the field and la Indoor unit gt the total refrigerant charge on the refrigerant charge label supplied wi
31. eep sound from the indoor unit and a transmit indicator appears on the remote controller display Remote controller buttons Remote controller display Power 1 Turn on off the air conditioner Mode Set one of the 4 operating modes see pages 10 11 for instructions SPi Set the SPi function on off Smart Saver Less energy usage makes your space cool between the temperature range of 24 C 30 C Quiet Reduce noise generated from an indoor unit during operation Turbo poss Operate in auto fan speed to cool quickly Air swing Activate Deactivate air flow blade movement automatically up and down Temp Fana Increase Decrease the temperature by 1 C Adjust how much air flows through the air conditioner with the 4 different fan speeds D such as Auto Low Medium High Temp Humi d light Cool Has no this funtion Has no this funtion good Sleep Filter Reset Beep Off Display Off Auto Clean Auto clean function Dry inside of the indoor unit to get rid of odor good sleep Set the good sleep mode on On Timer Set Cancel Set the On Timer on Cancel the timer good sleep mode Off Timer 2 Switch the function of the button on the remote controller Set the Off Timer on SAMSUNG Filter Reset Reset the Filter Clean reminder Beep off Has no this funtion Display off To turn off the display light lt When you press 2 4F button the indicator will be displ
32. ere you want to install the indoor unit Therefore before fixing the installation plate to a wall or a window frame you must determine the position of the 65mm hole through which the cable pipe and hose pass to connect the indoor unit to the outdoor unit When facing the wall the pipe and cable can be connected from the lt Right A Left B Underside right C Rear right or left D 1 Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards Pipe Unit mm n Model AB ED A lt Make sure to drill only one Id p Em dj 9 12 27 120 68 27 hole after choosing the 18 24 34 140 68 34 CAUTION direction of the pipe 29 2011 6 20 10 13 28 Fixing the installation plate 2 Fixthe indoor unit If you fix the indoor unit on a wall 1 Fixthe installation plate to the wall giving attention to the weight of the indoor unit v Plastic lt Ifyou mount the plate to a concrete wall using plastic anchors make sure that Anchor note gaps between the wall and the plate created by projected anchor is less than 20mm 4 20 If you fix the indoor unit on a window frame If you fix the indoor unit on a gypsum board 1 Determine the positions of the wooden uprights to be 1 Use stud
33. es then refrigerant connections If the outdoor unit is more than 7 5 meters away from the indoor unit you must extend the cable The maximum length of the cable is 20 meters 1 Extend the assembly cable if necessary lt Do not connect two or more different cables to extend the length lt may cause fire 30 Brazil AQV amp ASVO9PG BIM 32441A E indd 30 e 2011 6 18 11 11 40 2 Open the front grille 3 Remove the screw securing the connector cover 4 Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals Refer to the picture below lt Each wire is labeled with the corresponding terminal number NOTE 5 Pass the other end of the cable through the 65mm hole in the wall Close the connector cover by tightening the screw carefully Close the front grille Remove the terminal board cover on the side of the outdoor unit A Connect the cables to the terminals as seen in the picture B Each wire is labeled with the corresponding terminal number NOTE Indoor unit a Al 09 12 18 24 it eee Indoor unit Indoor unit Nij 1 2 t n Ground wire bd 4 Ground wire i Green Yellow Green Yellow 6 9 9 lt Ground wire 9 amp Green Yellow N 9 lt Ground wire Green Yell
34. et the time gt You can set the time in half hourly unit from 30 minutes hours and hour unit from 3 hours 12 hours Auto Temp good Clean Humi sign Filter Reset Beep Off Disf On off _Set_ Timer Timer Cancel Cool 3 gt Operating hour can be set from minimum 30 minutes to maximum 12 hours gt Default operation hour is set to 8 hours Press the Set Cancel button to active it on gt Off timer indicator stops blinking and reserved time will be displayed for 3 seconds Then the air conditioner operates in good sleep Cool mode Pu Met al gt If you dont press Set Cancel button within 10 seconds after pressing the good sleep button the air conditioner will return to previous status Check Off timer indicator and 325 indicator on the indoor unit Cancel Pressthe Set Cancel button once again Temp You can set the desired temperature by 1 C in the range of 16 C 30 C Fan speed will be adjusted automatically according to the good sleep 4 mode E However f you select good sleep mode while heating operation is on you can adjust fan speed Model Air flow direction will be adjusted automatically according to the good sleep mode However if you select good sleep mode while heating operation is on you can adjust air flow direction Model Temperature and fan speed changes in good sleep mode Fall asleep Eases
35. ge will be limited to 24 C 30 C If the desired temperature is lower than 24 C turn off the Smart Saver function by pressing the Smart Saver button again du Temperature Fan speed can also be adjusted see page 11 for instructions Air flow can be adjusted manually see page 12 for instructions If you press the Mode button while the Smart Saver function is on it will cancel the function 16 Brazil_AQV amp ASVO9P _IBIM_32441A_E indd 16 e 2011 6 18 natae Using the SPi function SPi Super Plasma ion generates hydrogen H and oxygen O to remove a polluted substance and decomposition of such harmful particles It makes you breathe better as if you are staying around waterfalls ocean surf rivers and mountains Press the button on the remote controller gt indicator will appears the remote controller display and the air conditioner generates MPI HSITDNA Cancel Press the button once again lt The t function can be selected whether the air conditioner is on off Using the Quiet function You can reduce the noise generated from an indoor unit Press the Quiet button on the remote controller while the air conditioner is operating c5 in Cool Heat mode E ode Quiet indicator appears the remote controller display s The indoor unit will operate more quietly Cancel Press the Quiet button once again o9o Cool B
36. gers or foreign substances into the outlet when the air conditioner is operating Take special care that children do not injure themselves by inserting their fingers into the product Do not touch the air flow blade with your hands or fingers during the heating operation gt This may result in electric shock or burns Do not insert your fingers or foreign substances into the air inlet outlet of the air conditioner gt Take special care that children do not injure themselves by inserting their fingers into the product Do not strike or pull the air conditioner with excessive force gt This may result in fire injury or problems with the product FOR USING A WARNING 5 e Do not place an object near the outdoor unit that allows children to climb onto the machine gt This may result in children seriously injuring themselves Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people gt Since this may be dangerous due to a lack of oxygen Open a window at least once an hour If any foreign substance such as water has entered the appliance cut the power by unplugging the power plug and turning the circuit breaker off and then contact your nearest service center Failing to do so may result in electric shock or fire HSITDNA Do not attempt to repair disassemble or modify the appliance yourself gt Do not use any fuse such as cooper steel wire etc other than
37. imer 3 hours Off timer 1 hour Ex On timer 3 hours Off timer 5 hours The air conditioner will operate the Off timer after The air conditioner will operate On timer after 3 hours m 1 hour from the moment you have set the timer from the moment you have set the timer Your air conditioner will turn on after 2 hours Your air conditioner will remain on for 2 hours and then pr turn off automatically On timer and Off timer setting time should be different from each other NOTE Pressthe Set Cancel button on the remote controller while timer combination is on Both of the On and Off timer will be canceled and the indicator will disappear 15 Brazil AQV amp ASVO9PG BIM 32441A E indd 15 e 2011 6 18 nae Using the Smart Saver function This function will set the temperature range limit to help you save energy while the air conditioner is operating in Cool mode QO NEL NE Cancel Pressthe Smart Saver button once again d SET 4c 8 Lic E Press the Smart Saver button on the remote controller while the air conditioner is operating in Cool mode gt Smart Saver indicator and air swing indicator appears automatically on the remote controller display The air flow blades move up and down gt Ifthe current set temperature is lower than 24 C it will automatically raise to 24 C Smart Saver function is only available in Cool mode When Smart Saver function is activated temperature ran
38. ire In the event of a gas leak such as propane gas LP gas etc ventilate immediately without touching the power plug Do not touch the appliance or power cord gt Do not use a ventilating fan gt Aspark may result in an explosion or fire To reinstall the air conditioner please contact your nearest service center gt Failing to do so may result in problems with the product water leakage electric shock or fire gt delivery service for the product is not provided If you reinstall the product in another location additional construction expenses and an installation fee will be charged gt Especially when you wish to install the product in an unusual location such as in an industrial area or near the seaside where it is exposed to the salt in the air please contact your nearest service center Do not touch the power plug or the circuit breaker with wet hands gt This may result in electric shock Do not unplug the power plug or turn the air conditioner off with the circuit breaker while it is operating gt Plugging the power plug into the wall outlet or turning the air conditioner on from the circuit breaker may cause a spark and result in electric shock or fire After unpacking the air conditioner keep all packaging materials well out of the reach of children as packaging materials can be dangerous to children gt Ifa child places a bag over its head it may result in suffocation Do not insert your fin
39. ke sure the power is turned off and unplugged from cmo the wall socket when cleaning the air conditioner I Cleaning the indoor unit gt Wipe the surface of the unit with a slightly wet or dry cloth when needed lt Contact the service center when you clean the indoor unit Note heat exchanger because it needs be disassembled lt Do not clean the display using alkaline detergent caution not use sulfuric acid hydrochloric acid organic solvents such as thinner kerosene and acetone etc to clean the surface of the product or put any stickers on it They may damage the surface of the air conditioner Cleaning the outdoor unit heat exchanger gt When dust accumulates on the heat exchanger it may decrease cooling performance Therefore clean it regularly gt Spray water to clean the dust If itis difficult to clean the outdoor unit heat exchanger on NOTE your own contact service center Be careful with the sharp edges on the outdoor unit heat exchanger Opening the panel Tightly grab top of the front panel and pull it down to open Then slightly lift the panel up Brazil AQV amp ASVO9PG 32441A E indd 19 e HSITDNA SSS SRR RRR RRR ed 00 TEE t a e 000000000000090000000 atate RRR XX Y Ye Heat exchanger Illustration may differ slightly
40. l AQV amp ASVO9PQG BIM 32441A E indd 2 e 2011 6 18 11 11 00 USING PARTS Safety precautions Before using your new air conditioner please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance Because the following operating instructions cover various models the characteristics of your air conditioner may differ slightly from those described in this manual If you have any questions call your nearest contact center or find help and information online at www samsung com HSITDNA Important safety symbols and precautions A WARNING Hazards or unsafe practices that may result in severe personal injury or death A CAUTION Hazards or unsafe practices that may result in minor personal injury or property damage ae Unplug the power plug from the o Follow directions e wallsocket S Do NOT attempt Do NOT disassemble Make sure the machine is grounded to prevent electric shock FOR INSTALLATION AAWARNING 0 Plug the power cord into a wall socket with the power specifications ofthe product or higher and use the socket for this appliance only In addition do not use an extension cord gt Sharing a wall socket with other appliances using a power strip or extending the power cord may result in electric shock or fire Donotusean electric transformer It may result in electric shock or fire gt Ifth
41. lt If using a multi system this function will work only when the Quiet function is NOTE seton all operated indoor units 17 Brazil AQV amp ASVO9PG BIM 32441A E indd 17 e 2011 6 18 nnas Using the Auto Clean function Auto clean function will prevent from growing mold by eliminating the moisture inside of the indoor unit Your indoor unit evaporates the moisture inside of the unit Activate this function to provide you with more clean and healthier air Temp good Humi Sleep Off Display Off Off Set Timer Cancel Press the Auto Clean button When the air conditioner is turned off The Auto clean indicator on the indoor unit display appears and the Auto cleaning function runs On Timer When the air conditioner is turned on gt After stopping the air conditioner operation the Auto clean indicator on the indoor unit display appears and the Auto cleaning function runs Auto Cleaning time can vary depending on the previously used mode Auto cool Cool Dry mode approximately 30 minutes Auto heat Model Heat Model Fan mode approximately 15 minutes Cancel Pressthe Auto Clean button once again When the air conditioner is turned on the Auto clean function runs after Note X Stopping the air conditioner operation 18 Brazil AQV amp ASVO9PG BIM 32441A E indd 18 e 2011 6 20 10 35 02 e Ma
42. model names written in simplified forms as indicated in following table Model Names Included Models Remark AQV ASVO9P AQV ASV12P AQV ASV18P AQV ASV24P Grouping was done by series KKK AQV ASVO9P X123 AQV ASV12P AQV ASV18PX Grouping was done by capacity AQV ASV24P Safety precautions Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components e Verify that installation and testing operations are performed by qualified personnel Verify that the air conditioner is not installed in an easily accessible area General information gt v v 24 Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation For maximum safety installers should always carefully read the following warnings Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred This manual explains how to install an indoor unit with a split system with two SAMSUNG units The use of other types of units with different control systems may damage the units and invalidate the warranty
43. n electric shock or fire When the appliance or power plug or power cord is damaged contact your nearest service center Plug the power plug into the wall socket firmly Do not use a damaged power plug damaged power cord or loose wall socket gt This may result in electric shock or fire Do not pull the power cord when unplugging the power plug b Unplug the power plug by holding the plug gt Failing to do so may result in electric shock or fire Do not pull or excessively bend the power cord Do not twist or tie the power cord Do not hook the power cord over a metal object place a heavy object on the power cord insert the power cord between objects or push the power cord into the space behind the appliance gt This may result in electric shock or fire FORPOWERSUPPLY A CAUTION e When not using the air conditioner for a long period of time or during a thunder lightning storm cut the power at the circuit breaker gt Failing to do so may result electric shock or fire FOR USING d waRNING 0 4 Brazil AQV amp ASVO9PG BIM 32441A E indd 4 e 2011 6 18 11 11 01 If the appliance is flooded please contact your nearest service center gt Failing to do so may result in electric shock or fire If the appliance generates a strange noise a burning smell or smoke unplug the power plug immediately and contact your nearest service center gt Failing to do so may result in electric shock or f
44. ons must always be performed by qualified personnel For more detailed information see the installation part in the manual Brazil AQV amp ASVO9PQG IBIM 32441A E indd 21 e 21 2011 6 18 11 11 28 Brazil AQV amp ASVO9PQG 32441A E indd 22 e Troubleshooting Refer to the following chart if the air conditioner operates abnormally This may save time and unnecessary expenses PROBLEM SOLUTION The air conditioner does Check power status and then operate the air conditioner again not work at all Plugin or switch on the circuit breaker and then operate the air conditioner again Checkif you have set the Off Timer Operate the air conditioner again by pressing the Power button The temperature lt Check if you have selected Fan Turbo mode In these modes desired temperature is set to adjustment is not working auto and you cannot adjust the temperature Cool Warm air does not come out of the air conditioner Check if the set temperature is higher during Cool mode lower during Heat mode Model AQV than the current temperature Press the Temp or button on the remote controller to change the set temperature Check if the Air filter is blocked by dirt If there is a lot of dust on the Air filter cooling heating Model performance may decrease Clean them frequently Check if the outdoor unit is covered or installed near the obstacle Take the cover off and tak
45. orming the gas leak tests Make sure to check for gas leaks before completing the installation process connecting the assembly pipe and hose between indoor unit and outdoor unit insulating the cables hose and pipe and fixing the indoor unit to the installation plate HSITDNA To check for gas leaks on the outdoor unit Check the valve A and B using a leak detector To check for gas leaks on the indoor unit Check the flare nut C and D using a leak detector Leak test with nitrogen before opening valves In order to detect basic refrigerant leaks before recreating the vacuum and recirculating the R410A it s responsible of installer to pressurize the whole system with nitrogen using a cylinder with pressure reducer at a pressure above 40 bar gauge Leak test with R410A after opening valves Before opening valves discharge all the nitrogen from the system and create vacuum according to page 36 38 After opening valves check leaks using a leak detector for refrigerant Pump down before disconnecting the refrigerant connections for unit repair removal or disposal Pump down is an operation intended to collect all the system refrigerant in the outdoor unit This operation must be carried out before disconnecting the refrigerant tubing in order to avoid refrigerant loss to the atmosphere Shut off the liquid valve with the Allen wrench Turn the system on in cooling with fan operating at high velocity
46. ow els Outdoor unit Outdoor unit 210 End of the wire must be circular caution After connecting the cables make sure terminal numbers on the indoor outdoor unit matches Screws on terminal block must not be unscrewed with the torque less than 12kgf cm 10 Connect the grounding conductor to the grounding terminals 11 Close the terminal board cover by tightening the screw carefully In Russia and Europe consult with the supply authority to determine the supply system impedance before installation Connect the wires firmly so that wires can not be pulled out easily If they are loose it could cause burn out of the wires Connect the wires according to color codes referring to the wiring diagram The power cable and the interconnection cable should be selected according to the specification in page 30 31 HSITDNA Brazil_AQV amp ASVO9P _IBIM_32441A_E indd 31 e 2011 6 18 11 11 41 Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field supplied copper pipes by means of flare connections Use insulated seamless refrigeration grade pipe only Cu DHP type according to 1501337 degreased and deoxidized suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa Under no circumstances must sanitary type copper pipe be used There are
47. p ASVO9PG BIM 32441A E indd 40 e 2011 6 18 11 11 51 Final Check and Trial Operation To complete the installation perform the following checks and tests to ensure that the air conditioner operates correctly Check the followings Strength of the installation site Tightness of pipe connection to detect gas leak Electric wiring connection Heat resistant insulation of the pipe Drainage Grounding conductor connection Correct operation follow the steps below HSITDNA 1 Press the Power 1 button and check the following gt The indicator on the indoor unit lights up gt The airflow blade opens and the fan gears up for operation 2 Press the Mode button to select Cool or Heat mode Model gt In Cool mode use Temp or button and set the temperature at 16 C gt In Heat mode use Temp or button and set the temperature at 30 C Model Approximately 3 5 minutes later outdoor unit will start to operate and the Cool or Warm air will blow out NOTE After 12 minutes of stationary condition check the indoor unit air treatment Cooling mode indoor unit check gt Inlet air temp Outlet air temp From 10 K to 12 K indicative delta T e Heating mode indoor unit check Outlet air temp Inlet air temp From 11 K to 14 K indicative delta T Model e In heating mode the indoor fan motor can remain off to avoi
48. pe 6 Attach the pipe to the wall using clamps optional Fixing the outdoor unit in place Install the outdoor unit in level on a stable base to avoid the generation of noise and vibration especially when installing the unit close to a neighbor aS e If you install the outdoor unit in a place exposed to strong winds or at a height fix it to an E appropriate support wall or ground 1 Place the outdoor unit as indicated on the top of the unit to let the discharged air Rubberleg F out properly Model X Y 2 Fix the outdoor unit in level to an appropriate support using anchor bolts 309 124 457 254 18K 538 290 3 Iftheoutd iti d to st inds install shield plat dth e outdoor unit is exposed to strong winds install shield plates around the SEHE 543 319 outdoor unit so that the fan can operate correctly B lt Secure the rubber leg to prevent the generation of noise and vibration NOTE Outdoor unit installed on the wall by rack Ensure the wall will be able to suspend the weight of rack and outdoor unit Install the rack close to the column as much as possible Install proper grommet in order to reduce noise and residual vibration transferred by outdoor unit towards wall from outdoor unit to rack not supplied with product Soft rubber designed to cut off vibration from rack to wall not supplied with product 40 Brazil AQV am
49. pment food animals plants or cosmetics or for any other unusual purposes gt This may result in property damage Avoid directly exposing humans animals or plants from the air flow from the air conditioner for long periods of time gt This may result in harm to humans animals or plants This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance FOR CLEANING A WARNING Do not clean the appliance by spraying water directly onto it Do not use benzene thinner or alcohol to clean the appliance gt This may result in discoloration deformation damage electric shock or fire Before cleaning or performing maintenance unplug the air conditioner from the wall socket and wait until the fan stops gt Failing to do so may result in electric shock or fire FOR CLEANING NCAUTION 9 Take when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges gt To avoid cutting your fingers wear thick cotton gloves when cleaning it Do not clean the inside of the air conditioner by yourself gt For cleaning inside the appliance contact your nearest service center gt
50. power cable 2 Insert both sides of core wire of the power cable into the connection sleeve 3 Using a compressor compress the two points and flip it over and compress another two points in the same location The compression dimension should be 8 0 After compressing it pull both sides of the wire to make sure it is firmly pressed 4 Wrap it with the insulation tape twice and position your F Insulation tape contraction tube in the middle of the insulation tape P 5 Apply heatto the contraction tube to contract it 40mm Contraction tube 6 After tube contraction work is completed wrap it with the Insulation tape insulation tape to finish 3 lt In case of extending the electric wire please DO NOT use a round shaped pressing socket A Incomplete wire connections can cause electric shock or a fire 42 Brazil AQV amp ASVO9PG BIM 32441A E indd 42 e 2011 6 18 1 11 58 HSITDNA 43 Brazil_AQV amp ASVO9P _IBIM_32441A_E indd 43 e 2011 6 18 1 11 58 emp QUESTIONS OR COMMENTS e COUNTRY CALL OR VISIT US ONLINE AT ARGENTINE 0800 333 3733 www samsung com BRAZIL P ON DON www samsung com CHILE 800 SAMSUNG 7 26 7864 www samsung com COLOMBIA 01 8000112112 www samsung com COSTA RICA 0 800 507 7267 www samsung com DOMINICA 1 800 751 2676 www samsung com ECUADOR 1 800 10 7267 www samsung com EL SALVADOR 800
51. rence of fires explosions or injuries To prevent injury when accidentally touching the indoor unit fan install the indoor unit at least 2 5m above the floor The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry gt Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs The unitscomponents must be accessible and that can be disassembled in conditions of complete safety either for people or things For this reason where it is not observed as indicated into the Installation Manual the cost necessary to reach and repair the unit in safety as required by current regulations in force with slings trucks scaffolding or any other means of elevation wont be considered in warranty and charged to end user Power supply line fuse or circuit breaker gt Always make sure that the power supply is compliant with current safety standards Always install the air conditioner in e compliance with current local safety standards Always verify that a suitable grounding connection is available Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric
52. rrect Inclined Damaged Cracked Uneven Surface Thickness 6 Alignthe pipes to connect them easily Tighten the flare nuts first with your hands and then with a torque wrench applying the following torque Flare nut Outer Diameter Torque kgf cm 06 35 mm 140 170 09 52 mm 250 280 012 70 mm 380 420 015 88 mm 440 480 019 05 mm 990 1210 Indoor outlet pipe Connecting pipe 02223 mm 990 1210 lt Excessive torque be cause of gas leakage case brazing the pipe the nitrogen gas must be blown into the note pipe 50 The joint must be accessible and serviceable 7 Forfurther details on how to connect to the outdoor unit and purge the air refer to page 36 38 lt Tighten the flare nut with torque wrench according to specified method lf the flare nut is over tightened the flare may break and cause refrigerant gas leakage Installing and connecting the drain hose of the indoor unit When installing the drain hose for the indoor unit check if condensation draining is adequate When passing the drain hose through the 65 mm hole drilled in the wall check the followings Ar Wall Indoor unit 0 N Drain hose ED The drain hose must NOT The end of the drain hose must NOT slant upwards be placed under water 1 LE 0 0 0 15cm tess Ditch The drain hose must not Keep a clearance of at least Do not place the end of
53. s with heavy snow fall piled snow could block the air intake TO avoid this incident install a frame that is higher than estimated snow Estimated snow fall fall In addition install a snow proof hood to avoid snow from piling on the outdoor unit Ground Purging the connected pipes The outdoor unit is loaded with sufficient R410A refrigerant Do not vent R410A into atmosphere it is a fluorinated greenhouse gas covered by Kyoto Protocol with a Global Warming Potential GWP 1975 You should purge the air in the indoor unit and in the pipe If air remains in the refrigerant pipes it affects the compressor It may cause reduction of cooling capacity and malfunction Refrigerant for air purging is not charged in the outdoor unit Use Vacuum Pump as seen in the picture When installing make sure there is no leakage When recovering the refrigerant ground the compressor first before removing the connection pipe If the refrigerant pipe is not properly connected and the compressor works with the service valve open the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high It may cause explosion and injury 1 Connecteach assembly pipe to the appropriate valve on the outdoor unit and Outdoorunit 4 unt tighten the flare nut pas pipe side 2 Tighten the flare nut first with your hands and then with
54. tallation CAUTION Cutting or extending the pipe A 7 5 meter pipe is supplied with the air conditioner The length ofthe pipe can be Extended up to see table page 24 Shorten up to see page 24 If you need a pipe longer than 7 5 meters caution You must extend the assembly cable You must add refrigerant to the pipes otherwise the indoor unit may freeze 1 Make sure that you have all the required tools pipe cutter reamer flaring tool and pipe holder 2 Ifyou want to shorten the pipe cut it using a pipe cutter ensuring that the cut edge remains at 90 with the side of the pipe see below examples of correct and incorrect cut edges Oblique Burr op 3 Topreventa gas leak remove all burrs at the cut edge of the pipe using a reamer A Face the pipe down while removing the burrs to make sure that burrs do not get in to the pipe CAUTION 4 Puta flare nut slightly into the pipe and modify the flare D Outer Diameter D Depth A Flaring Size B crane 8 r F 06 35 mm 1 3 mm 9 0 mm 09 52 mm 1 8mm 13 0 mm 012 70 mm 2 0 mm 16 2 mm 915 88 mm 22mm 193mm 019 05 mm 22 225mm Pipe Flare 022 23 mm 2 2mm 25 7mm 33 Brazil AQV amp ASVO9PG BIM 32441A E indd 33 e 2011 6 18 11 11 42 Cutting or extending the pipe 5 Check if you flared the pipe correctly see examples of incorrectly flared pipes below Hmmm Co
55. th the product a Factory refrigerant charge of the product NOTE see unit name plate b Additional refrigerant amount charged the field Refer to the above information for the quantity of refrigerant door unit replenishment c Total refrigerant charge kg d Refrigerant cylinder and manifold for charging lt The filled out label must be adhered in the proximity of the product charging port e g onto the inside of the stop A valve cover Charging the refrigerant under conditions of liquid by using a liquid pipe R410A is a mixed type of refrigerant It is necessary for recharging under conditions of liquid When recharging refrigerant from the refrigerant cylinder to the equipment follow the instructions below 1 Before recharging check whether the cylinder has a siphon or not There are two ways to recharge the refrigerant Cylinder with siphon Cylinder without siphon 7 siphon gt Charge the refrigerant standing the l gt Charge the refrigerant turning the cylinder cylinder upright upside down If R410A refrigerant is charged with gas the composition of the charged refrigerant changes and the note Characteristics of the equipment vary During the measuring operation of refrigerant quantity added use an electronic balance If cylinder doesn t have syphon upset it 38 Brazil AQV amp ASVO9PG BIM 32441A E indd 38 e 2011 6 18 Perf
56. that stick out of the air flow blades are not broken DSSS Move the blade pin lever left or right to keep the air flow direction in a constant D position you prefer lt Be extremely careful with your fingers while adjusting the Horizontal air flow direction There is a potential risk of personal injury when the unit is mishandled Using the Turbo function Turbo function will be helpful to cool your room quickly and effectively Press the Turbo button on the remote controller during Cool mode gt Turbo indicator appears on the remote controller display and the air conditioner operates in Turbo function for 30 minutes Cancel Press the Turbo button once again Turbo function is only available in Cool mode NOTE Ifyou press the Mode button while the Turbo function is on it will cancel the function lt Temperature Fan speed cannot be adjusted while using this function 12 Brazil_AQV amp ASVO9P _IBIM_32441A_E indd 12 e 2011 6 18 11 11 12 good sleepmode For a comfortable sleep the air conditioner will operate it Fall asleep gt Sound sleep gt Wake up from good sleep mode When the air conditioner is on and in cool heat mode Model AQV 1 Press the good sleep button on the remote controller gt good sleep indicator appears and Off timer indicator starts blinking on the remote controller display HSITDNA 2 Press the good sleep button to s
57. the be bent 5cm between the end of the drain hose in a hollow drain hose and the ground 34 Brazil_AQV amp ASVO9P _IBIM_32441A_E indd 34 e 2011 6 18 11 11 44 TE I Drain hose installation 1 2 3 If necessary connect the 2 meter extension drain hose to the drain hose If you use the extension drain hose insulate the inside of the extension drain hose with a shield Fit the drain hose into 1 of 2 drain hose holes then fix the end of the drain hose tightly with a clamp HSITDNA B Ifyou do not use the other drain hose hole block it with a rubber stopper NOTE 4 Pass the drain hose under the refrigerant pipe keeping the drain hose Shield 5 Pass the drain hose through the hole in the wall Check if it slants tight N A ETE Drain hose Extension drain hose downwards as seen in the picture The hose will be fixed permanently into position after finishing the installation and the gas leak test refer to page Note 39 40 for further details lt Make sure the installed direction of the drain hose is correct canon Inadeguate installation may cause condensate water leakage lt Ifthe drain hose is routed inside the room insulate the hose so that dripping condensation does not damage the furniture or floors lt DO NOT WALL UP THE DRAIN HOSE CONNECTION Drain hose connection must be easy accessible and serviceabl
58. the remote controller display 2 Pressthe On Timer Off Timer button to set the time gt You can set the time in half hourly unit from 30 minutes 3 hours and hour unit from 3 hours 24 hours gt Operating hour can be set from minimum 30 minutes to maximum 24 hours 3 Pressthe Set Cancel button to active it on gt On timer indicator stops blinking and reserved time will be displayed for 3 seconds gt If you dont press Set Cancel button within 10 seconds after selecting the time the air conditioner will return to previous status Check On timer or Off timer indicator and 1 indicator on the indoor unit Cancel Press the Set Cancel button Additional options available in On timer mode You can select from Auto Cool Dry Fan Heat Model AQV gt k Fan You can adjust the fan speed in Cool Fan Heat mode Model You can adjust the temperature in Auto Cool Dry Heat mode Model AQV lt Only the latest setting timer will be applied between the On Timer Off Timer Nore and good sleep Off timer functions After setting the timer the set time will be displayed for 3 seconds before it disappears Brazil AQV amp ASVO9PG BIM 32441A E indd 14 e 2011 6 18 nnas Combining Timer and Off Timer If the air conditioner is on If the air conditioner is off Preset time on On timer is longer than Off timer Preset time on On timer is shorter than Off timer Ex On t
59. ther details on how to connect to the outdoor unit and purge the air refer to page 36 38 lt The pipe will be insulated and fixed permanently into position after finishing the installation and the gas leak test Note referto page 39 for further details lt Tighten the flare nut with torque wrench according to specified method lf the flare nut is over tightened the flare may break and cause refrigerant gas leakage lt DO NOT WALL UP THE PIPE CONNECTION All refrigerant pipe connection must be easy accessible and serviceable 32 Brazil_AQV amp ASVO9P _IBIM_32441A_E indd 32 e 2011 6 18 11 11 41 Purging the indoor unit The indoor unit is supplied with inert gas nitrogen Before installing the unit check if nitrogen gas flow out of indoor unit If this one isn t true DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit 1 Unscrew the caps at the end of each pipe gt All inert gas exhausts from the indoor unit To prevent dirt or foreign substances from getting into the pipes during Note installation do NOT remove the caps completely until you are ready to connect the pipes A U th Theremaining air in the Refrigeration cycle which contains moisture DRE HUI caps may cause malfunction on the compressor lt Always contact the service center or a professional installation agency for product ins
60. tioner operates internal battery in Cool mode Protect compressor The air conditioner does not start operating immediately to protect the compressor of the outdoor unit after it has been started Ifthe heat pump is operating in Heat mode De ice cycle is actuated to remove frost from an outdoor unit that may Note have deposited at low temperatures The internal fan is switched off automatically and restarted only after the de ice cycle is completed 6 Brazil AQV amp ASVO9PG 32441A E indd 6 e 2011 6 18 TE ZS TE Checking the name of the parts Your air conditioner may slightly look different from illustration shown above depending on your model Main parts HSITDNA Room temperature sensor nan Air filter under the panel Air flow blade up and down Blade pin lever Air flow blade left and right Display SPi indicator d o Timer Auto clean indicator o Operation indicator Ms Power l button mc Remote controller receiver gt 1 Brazil AQV amp ASVO9PG 32441A E indd 7 e 2011 6 18 11 11 04 TE Checking the remote controller Pointthe remote controller towards the remote controller receiver of the indoor unit When you properly press the button on the remote controller you will hear b

Download Pdf Manuals

image

Related Search

Related Contents

KM 130/300 R Bp  Hoefer HE99X  Poulan 428550 Snow Blower User Manual  Samsung L301 Manuel de l'utilisateur  MANUALE UTENTE - Icon Heath & Fitness  EUROLITE Euro Strobe User Manual (#4713)  Hikvision Digital Technology DS-1671ZJ  Samsung Galaxy J SC-02F ユーザーマニュアル  tipo VM102 624 - TECNEL NOVELLARA  Mini Single-Port Twisted Pair-to-Fiber Converter  