Home

Samsung AC160CB User Manual

image

Contents

1. Contents PREPARING FOR THE AIR CLEANER m Safety Precautions 2 m View of the Unit 4 m Getting Started 7 OPERATING THE AIR CLEANER m Selecting the Auto Mode 8 m Selecting the Turbo Mode 9 m Selecting the Sleep Mode 10 ADDITIONAL FUNCTION m Generating 5 11 RECOMMENDATIONS FOR USE Cleaning the Air Cleaner 12 Solving Common Problems 14 TECHNICAL SPECIFICATIONS Correct Disposal of This Product Waste Electrical amp Electronic Equipment pem Applicable in the European Union and other European countries with separate collection systems This marking shown on the product or its literature indicates that it should not be disposed with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe
2. better clean the Washable Filters every 3 months The cleaning frequency of the Washable Filters may vary according to the time and place that the air cleaner is operated Before cleaning the air cleaner make sure that the power supply is disconnected 1 Open the front panel and pull out the Washable Filter Section 2 Wash the Washable Filter Section under lukewarm tap water Washable Filter oo axe 7 Section Not If the filter is too contaminated leave it in warm water mixed with neutral detergent for 30 minutes and brush the contaminants with a soft brush The Pre Filter is easy to clean because it can be taken out of the Washable Filter Section and washed separately Do not wash the filters with salt water The metal parts can be rusted 3 Leave the Washable Filter Section in the shade to dry for over 12 hours Note During this process make sure that the filter is not exposed to direct sunlight because the sun s rays may affect the transformation of the filter case 4 Put the Washable Filter Section back into the place and assemble the front panel Pre Filter Cleaning the External Surface of the Air Cleaner 1 Clean the external surface of the air cleaner with a damp soft cloth and neutral detergent Note Do NOT use benzene solvents or other chemicals ENGLISH Recovering the Photocatalyst Filter The Photocatalyst filter eliminates various odors in the indoor air 1 Open t
3. Make sure that the product is used in a location that ensures enough space at least 5 cm in front of the air inlet Make sure that there are no obstacles near the air inlet and outlet of the product If a strange noise burning smell or smoke come from the product disconnect the power supply immediately and consult with an authorized service personnel Do not use this product except purifying air Do not spill any kind of liquids into the product Do not place containers containing liquid substances on the top of the product Do not apply excessive impact on the product When using this product in a closed area that combustible fuels are fired make sure to ventilate the air occasionally Do not use the product in places that have a high temperature and humidity level such as a bathroom or a sauna Before cleaning or repairing the product make sure that the power supply is disconnected and the fan is stopped Do not use substances such as benzene thinner or alcohol to clean the surface of the product Do not open the front panel when the product is in operation When drying the washable filters do not expose it to direct sunshine The powerful sunshine may affect the transformation of the filter case Do not touch the Washable Filter Section with wet hands because the user may be received an electric shock This is especially true for the Washable Filter Section where a high voltage current flow
4. recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal ENGLISH View of the Unit ime i999 M Odor sensor _ ai Power plug p Air outlet Control part Front panel ENGLISH 8 8 Steps Cleaning System Washable Filter Section Replacement Filter Fixed Filter Section Pre filter lonizer Electrostatic Metal Nano Photocatalyst Anti bacterial Anion filter filter silver filter fan generator formula Note The Metal filter is coated with the Nano silver particles View of the Unit cont Operating Mode indicator Bionizer button 2 2e TURBO Bionizer 4 EZ Mode Auto Turbo Sleep Bionizer Bionizer indicator Power Mode button Note Bionizer Bionizer is the registered trademark of the SAMSUNG ELECTRONICS Co Ltd and generates anions for your health For further details about anion refer to page 11 ENGLISH Getting Started i If you purchase this air cleaner it has to be used according to the safety precautions of page 2 This manual contains important information conceming use of your air cleaner Please take some time to read this booklet as it will help you take full advantage of the product s features The booklet is organized as follows The chapter V
5. 2 KATAZKEYAZETAI ANO THN LT ELECTRONICS
6. OWNER S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D UTILISATION ISTRUZIONI PER L USO MANUAL DE INSTRUCOES GEBRAUCHSANWEISUNG OAHME2 TON IAIOKTHTH AC160C AC160CB AC160CP Air Cleaner Filtro de Aire Purificateur d air Depuratore d aria Purificador de Ar Luft Reiniger lovioThc DB98 18998A 3 EAAHNIKA DEUTSCH PORTUGU S ITALIANO FRAN AIS ESPA OL ENGLISH Register your product at www samsung com global register Safety Precautions The following safety precautions must be taken into account when using this product Do not place this product in places where it will come into contact with A WARNING combustible gases such as sulfuric gas hydrogen gas methane gas etc Do not place this product in places that are exposed to direct sunlight near heating equipments and wet places When using this product do not bend the wire excessively or place a heavy object on it The wire may be disconnected or damaged Avoid using inflammable spray gases such as insecticides near this product Prevent children from inserting their fingers or objects into the air inlet and outlet Do not attempt to repair this product by yourself If the product needs repairing consult with an authorized service personnel Do not use this product on surfaces that are not even or slant A CAUTION This may cause the malfunction or make a strange noise due to vibration
7. e human body Use this function if you want to feel refreshed both physically and mentally just as if you were in the midst of a forest If the air deaner is tumed on the Bionizer function is selected automatically 1 If necessary press the Power button Result The air cleaner runs in the Auto mode y gt The air cleaner makes a ringing sound 2 Ifthe 2e is not displayed on the control part select the Bionizer function by pressing the button Result The air cleaner beeps The Bionizer indicator lights up on the control part The air cleaner generates anions into the indoor air ionizer 3 If you wish to turn off the Bionizer function press the se button again Result The Bionizer indicator disappears on the control part The air cleaner stops generating anions into the indoor air Note Anions are ultra fine particles charged negatively in the air There are vast quantities of them in nature for example near waterfalls or in the midst of a forest When inhaling in sufficient quantities anions can enhance the metabolism of your blood cells help you recover from fatigue faster and calm your nerves Cleaning the Air Cleaner Cleaning the Washable Filters Washable Filters are responsible for eliminating fine particles of dust molds and mites in the air that are as small as 0 5 microns It also has the function of sterilizing virus or bacteria in the air in your room You had
8. he front panel and pull out the Photocatalyst filter after pulling out the Washable Filter Section Photocatalyst filter 2 Dry the Photocatalyst filter under the sunlight at least for 8 hours Nota The more frequently you dry the Photocatalyst filter under the sunlight you can use the filter more efficiently You can purchase new photocatalyst filters in the authorized service center Replace the Photocatalyst filter with new one after using it for y about 3 years because the capacity of the Photocatalyst filter 7 not be recovered A PORTANT Don t wash the Photocatalyst filter It must be dried only under the sunlight every 6 months 3 After pushing the Photocatalyst filter and the Washable Filter Section Photocatalvst filter back into the place assemble the front panel Solving Common Problems Before contacting the after sales service perform the following simple checks This may prevent you from making an unnecessary call and wasting your time and money Problem Explanation Solution The air cleaner does not operate Check for a power failure Check that the power plug is plugged in tightly Check that the power outlet is not of a poor quality Check that the front panel is closed properly The air cleaner stops its operation abruptly Unpleasant odors can be detected coming from the air cleaner Check whether the front panel was opened during o
9. iew of the Unit is shown from pages 4 to 6 It will help you find the buttons and understand the symbols that are displayed Inthe manual you will find a series of step by step procedures for each function available Three types of symbols are used to help you understand the illustrations i in the step by step procedures HOLD DOWN Selecting the Auto Mode Gp CO Mode J lt vid N Lao gt Auto Y 4 29 gt lt Bionizer In the Auto mode the air deaner operates according to the contamination level In this mode the optimum fan speed is adjusted automatically and the Bionizer function is selected automatically 1 95 If necessary press the Power button Result 4 The air cleaner runs in the Auto mode The air cleaner makes a ringing sound 2 Ifthe Laut is not displayed on the control part select the Auto mode by pressing the c button until it is displayed on the control part of the air cleaner Result The air cleaner beeps The air cleaner operates in the Auto mode Note You can change modes at any time 3 To adjust the Bionizer function refer to page 11 Selecting the Turbo Mode In the Turbo mode you can clean the air as quickly as possible The fan in the air cleaner tums in the fastest setting to clean the air The Bionizer function is selected automatically 1 If necessary press the Power button Result The air c
10. leaner runs in the Auto mode The air cleaner makes ringing sound Mode 2 Ifthe is not displayed on the control part select the Turbo mode by pressing the gt button until it is displayed on the control part Result The air cleaner beeps The air cleaner operates in the Turbo mode vd vd lt TURBO j gt 4 2e p Note You can change modes at any time gt lt 4 Turbo Bionizer 3 To adjust the Bionizer function refer to page 11 ENGLISH Selecting the Sleep Mode y 4 4 I Q lt 20 A 4 gt 4 Auto Turbo Sleep 8ionize 1 f necessary press the q If you wish the air cleaner to clean the air in your room quietly select the Sleep mode In this mode the air cleaner runs in the quietest setting and the Bionizer function is selected automatically Power button Result The air cleaner runs in the Auto mode The air cleaner makes a ringing sound 2 Ifthe is not displayed on the control part select the Sleep mode by pressing the A button until it is displayed on the control part Result The air cleaner beeps The air cleaner operates in the Sleep mode Note You can change modes at any time 3 To adjust the Bionizer function refer to page 11 Note Inthe Sleep mode the display brightness gets dimmer so that it may not disturb your sleep Generating Anions ENGLISH Bionizer generates anions which are benefidal to th
11. peration Press the Power button if you wish to restart the air cleaner Mode Check that the air cleaner is used in places that have a high level of odor permeating contaminants in the air The air cleaner cannot fully function in an environment where the level of contamination is too high Check whether the dirty filters are in the front panel The brightness of the control part is too dim The air in the room still feels unclean Check whether the air cleaner operates in the Sleep mode In the Sleep Mode the control part automatically diminishes its brightness to ensure a comfortable sleeping setting Check whether the filters in the Washable Filter Section and the Photocatalyst filter have been cleaned and replaced regularly Check that there are no additional contaminants entering the room through open windows and doors indicator blinks Contact the service center when the sensor senses contaminants improperly Lano indicator blinks Contact the service center when the fan motor operates improperly Technical Specifications ENGLISH Model Power Supply AC160C AC160CB 220 240V 50 60Hz AC160CP THIS AIR CLEANER IS MANUFACTURED BY ESTE FILTRO DE AIRE HA SIDO FABRICADO POR CE PURIFICATEUR D AIR EST FABRIQUE PAR QUESTO DEPURATORE D ARIA PRODOTTO DA ESTE PURIFICADOR DE AR E FABRICADO POR DIESER LUFT REINIGER IST FABRIZIERT VON AYTO TO IONIZTH

Download Pdf Manuals

image

Related Search

Related Contents

Samsung 23,4" Curved Monitor SE650C Bruksanvisning  Mode d`emploi - Houillères de Cruéjouls  PNL-tec SS-860XP  White Rodgers 1F95-1291 Thermostat User Manual  XL-2T-VER-3 - Altoona Computers  ! CUIDADO: Leia as informações sobre segurança no manual de  SurvCalc manual 12March2012 - These are not the droids you are  Print Center User Manual  