Samsung AS09ESQ User Manual
Contents
1. 33 HSITON3 Purging the connected pipes The outdoor unit is loaded with sufficient R22 refrigerant for a 5 meter pipe You should purge theair in the indoor unit and in the pipe If air remains in the refrigerant pipes it affects the compressor It may cause reduction of cooling capacity and malfunction e When installing make sure there is no leakage When recovering the refrigerant ground the compressor first before removing the connection pipe If the refrigerant pipe is not properly connected and the compressor works with the service valve open the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high It may cause explosion and injury 1 Connect each assembly pipe to the appropriate valve on the outdoor unitand Outdoor unit Indoor unit tighten the flare nut Gas pipe side ai a KI 2 Tighten the flare nut first with your hands and then with a torque wrench Liquid pipe side m a ee applying the following torque o B Excessive torque can be cause of gas leakage Outer Diameter Torque kgf cm NOTE a Ab eee A a a i 66 35 mm 140 170 69 52 mm 250 280 612 70 mm 380 420 615 88 mm 440 480 3 Connect the charging hose of the low pressure side of manifold gauge to a Manifold gauge gas service port as seen in the picture 4 Open the valve of the low pressure side of manifold gauge counte
2. HSITON3 INSTALLATION PARTS x In this manual you may find model names written in simplified forms as indicated in following table Model Names Included Models AS XXE XX ASO9E AS 12E AS 18E 3k AS24E XX Grouping was done by series 09 ASO9E KK IDK AS12E Grouping was done by capacity K18 KK AS18E K 24K AS24E Safety precautions Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment e Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components e Verify that installation and testing operations are performed by qualified personnel e Verify that the air conditioner is not installed in an easily accessible area General information gt Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation For maximum safety installers should always carefully read the following warnings Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred gt This manual explains how to install an indoor unit with a split system with two SAMSUNG units The use of other types of units with different control systems may damage the units and invalidate the warranty The manufacturer shall not
3. Failing to do so may result in injury death or property damage Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency Do not stand on top of the appliance or place objects such as laundry lighted candles lighted cigarettes dishes chemicals metal objects etc on the appliance gt This may result in electric shock fire problems with the product or injury Do not operate the appliance with wet hands gt This may result in electric shock Do not spray volatile material such as insecticide onto the surface of the appliance gt As well as being harmful to humans it may also result in electric shock fire or problems with the product Do not drink the water from the air conditioner gt The water may be harmful to humans Do not apply a strong impact to the remote controller and do not disassemble the remote controller Do not touch the pipes connected with the product gt This may result in burns or injury Do not use this air conditioner to preserve precision equipment food animals plants or cosmetics or for any other unusual purposes gt This may result in property damage Avoid directly exposing humans animals or plants from the air flow from the air conditioner for long periods of time gt This may result in harm to humans animals or plants This appliance is not intended for use by persons including children with reduced physi
4. q up and down I Air flow blade Blade pin lever i left and right spi indicator Display Temperature Evaporator clean 1 indicator Operation indicator Timer indicator Smart Saver indicator Remote control receiver Filter Clean reminder a Power button HSITON3 Checking the remote controller Point the remote controllertowards the remote controller receiver of the indoor unit When you properly press the button on the remote controller you will hear beep sound from the indoor unit and a transmit indicator A appears on the remote controller display Remote controller buttons Power Q Turn on off the air conditioner Mode Set one of the 5 operating mods see pages 10 11 for instructims Quiet Reduce noise generated from an indoor unit during operation Air swing 5 Activate Deactivate air flow blade movement SPi 8 3 SPi Set the SPi function on off Smart Saver Less energy usage makes your space cool between the temperature range of 24 C 30 C Turbo nasa ag up and down Operate in auto fan speed to Adjust how much air flows through the air cool quickly conditioner with the 4 different fan speeds such as Auto Low Medium High The d light Cool function is not available co X good for this model Temp Increase Decrease the temperature by 1 C E AEE EN E Pi Uo ca sleep J good sleep uto clean function Dr
5. After 2 minutes of operation shut the suction valve with the same wrench gt Turn the system off and switch mains supply off gt Disconnect tubing After disconnection protect valves and tubing ends from dust gt Compressor damage may occur if run at a negative suction pressure Fixing the indoor unit in place Perform the following work on the area where gas leak test was done priorly After checking for gas leaks in the system insulate the pipe hose and cables Insulation Then place the indoor unit on the installation plate 1 To avoid condensation problems wrap foam insulation as shown in the figure on a 2 part without insulation on the end of the pipes I 2 Wind the pipe assembly cable and drain hose with vinyl tape 3 Place the bundle the pipe assembly cable and drain hose in the lower part ETET of the indoor unit carefully so it does not project from the rear of the indoor plate unit Vinyl tape 4 Hookthe indoor unit to the installation plate and move the unit to the right Connecting wires and left until it is securely in place Drain hose Make sure pipe does not move when you install the indoor unit on caution a installation plate 5 Wrap the rest of the pipe with vinyl tape 6 Attach the pipe to the wall using clamps optional Fixing the outdoor unit in place Install the outdoor unit in level on a stable base to avoid the generation of noise and vibration X mm especially when insta
6. FOR ITALY The length of the pipe can be Extended up to see table page 24 e Shorten up to see table page 24 If you need a pipe longer than 5 meters caution You must extend the assembly cable You must add refrigerant to the pipes otherwise the indoor unit may freeze 1 Make sure that you have all the required tools pipe cutter reamer flaring tool and pipe holder 2 If you want to shorten the pipe cut it using a pipe cutter ensuring that the cut edge remains at 90 with the side of the pipe see below examples of correct and incorrect cut edges Pipe 90 Oblique cutter e2 Pipe D Outer Diameter D Depth A Flaring Size B a 66 35 mm 1 3mm 9 0 mm a 09 52 mm 1 8 mm 13 0 mm A 012 70 mm 2 0 mm 16 2 mm A 015 88 mm 2 2 mm 19 3 mm Pipe Flare 31 HSITON3 Cutting or extending the pipe 5 Check if you flared the pipe correctly see examples of incorrectly flared pipes below Correct Inclined Damaged Cracked Uneven Surface Thickness 6 Align the pipes to connect them easily Tighten the flare nuts first with your hands and then with a torque wrench applying the following torque Flare nut Outer Diameter Torque kgf cm 66 35 mm 140 170 69 52 mm 250 280 baha 612 70 mm 380 420 615 88 mm 440 480 Indoor outlet pipe Connecting pipe Excessive torque can be cause of gas leakage In case brazing the pipe the nitrogen gas must be blown into the
7. Fan speed indicator SK sl Auto Turbo a Low SOng Medium Heal High d light Cool indicator When the battery is exhausted Z1 will be displayed in the remote controller display When the icon appears change the batteries The remote controller requires two 1 5V AAA type batteries Storing the remote controller When you do not use the remote controller for long time remove the batteries from the remote controller and store it Inserting the batteries 1 Push the lever as arrow 2 Insert two AAA batteries indicates on the rear side of the Check and match the 4 and remote controller and pull up signs accordingly Make sure you have inserted the batteries in correct position 4 3 Close the cover by place it back to its original position You should hear click sound when the cover is locked properly The signal may not be received well of electronic lighting style fluorescent lamps such as inverter fluorescent lamps Note arein the same space e Ifother electrical products operate by the remote controller call your nearest contact center HSITON3 Basic function Basic operation is an operation mode that can be selected by pressing the Mode button og Auto In Auto mode the air conditioner will automatically set the temperature and fan speed depending on the room temperature detected by the room temperature Cool lai In Cool mode the air conditioner will cool you
8. NOTE Pipe 50 Pa The joint must be accessible and serviceable 7 For further details on how to connect to the outdoor unit and purge the air refer to page 34 35 A Tighten the flare nut with torque wrench according to specified method caution __ the flare nut is over tightened the flare may break and cause refrigerant gas leakage Installing and connecting the drain hose of the indoor unit When installing the drain hose for the indoor unit check if condensation draining is adequate When passing the drain hose through the 65 mm hole drilled in the wall check the followings The drain hose must NOT The end of the drain hose The drain hose must not slant upwards must NOT be placed under be bent water After completing the installation of the drain hose pour water into U pL the drain pan to check MENN whether the hose is well 0 INE drained 5cm less alg Ditch Keep a clearance of atleast Do not place the end of the 5cm between the end of the drain hose in a hollow drain hose and the ground 32 Drain hose installation 1 If necessary connect the 2 meter extension drain hose to the drain hose 2 If you use the extension drain hose insulate the inside of the extension drain hose with a shield 3 Fit the drain hose into 1 of 2 drain hose holes then fix the end of the drain hose tightly with a clamp 5 Ifyou
9. When the upper part of the outdoor unit and units the air outlet is opposite the wall LIAL TAT AIL ALATA EA DG A fea A i o o o z gt vp c A a A a 1 p O Su m y o J 3 600 or more gt ha 600 or more KO Gg x When front and rear side of the outdoor unit is towards the wall le Ue el Ld pag 1500 or 600 or 3000 or 3000 or 200 or more more more more more 300 or more 500 or more Ifinstallation is done in inappropriate space unit may generate sound and cause bad effect on the product caution Installation must be done in level and in a place where vibration will not cause any effect Accessories The following accessories are supplied with the air conditioner E The number of each accessory is indicated in parentheses NOTE Accessories in the Indoor Unit Case Installation Plate 1 Installation Plate 1 Remote Control 1 Remote Control Batteries for Assy Instruction 09 12 Perr Holder 1 Remote Control 2 Manual 18 WS 3 wire 3 wire 3 wire Assembly Cable 1 Power Cable 1 Power Cable 1 AS09 12 x AS18xx AS24 The flare nuts are attached to the end of each pipe of an evaporator or a service port Use the nuts when connecting the pipes The wire assembly cable is optional If it is not supplied use the standard cable The drain plug and rubber leg are only included wh
10. be responsible for damages arising from the use of non compliant units gt The air conditioner is compliant with the requirements of the Low Voltage Directive 72 23 EEC the EMC Directive 89 336 EEC and the Directive on pressurized equipment 97 23 EEC gt The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and requirements set forth in the Operating limits table included in the manual shall immediately invalidate the warranty gt The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry Do not use the units if damaged If problems occur switch the unit off and disconnect it from the power supply gt In order to prevent electric shocks fires or injuries always stop the unit disable the protection switch and contact SAMSUNG technical support if the unit produces smoke if the power cable is hot or damaged or if the unit is very noisy gt Always remember to inspect the unit electric connections refrigerant tubes and protections regularly These operations should be performed by qualified personnel only gt The unit contains moving parts which should always be kept out of the reach of children Do not attempt to repair move alter or reinstall the unit If performed by unauthorized personnel these operations may cause electric s
11. return to previous status Check On timer or Off timer indicator and D indicator on the indoor unit On or Set Timer Timer Cancel N Press the Set Cancel button Cancel Additional options available in On timer mode You can select from Auto Cool Dry Fan Heat Heat model AQ series SET i ET pal LA i al You can adjust the fan speed in Cool Fan Heat mode Heat model AQ series You can adjust the temperature in Auto Cool Dry Heat mode Heat model AQ x series e Only the latest setting timer will be applied between the On Timer Off Timer Note andgood sleep Off timer functions After setting the timer the set time will be displayed for 3 second beforre it diseppears If Timer function is used in Heating mode Air conditioner work into former mode AS Series 14 Combining On Timer and Off Timer If the air conditioner is on If the air conditioner is off The air conditioner will operate the Off timer after The air conditioner will operate On timer after 3 hours aa 1 hour from the moment you have set the timer from the moment you have set the timer a Your air conditioner will turn on after 2 hours Your air conditioner willremainonfor2 hoursandthen E turn off automatically lt On timer and Off timer setting time should be different from each other NOTE Pressthe Set Cancel button on the remote controller while timer combination is on Both of t
12. shock or a fire z 39 HSITON3 sam SUN OR VISIT US ONLINE AT www samsung com www samsung com www samsung com www samsung com www samsung com www samsung com www samsung com www samsung com www samsung com www samsung com www samsung com QUESTIONS OR COMMENTS COUNTRY CALL IRAN 021 8255 www samservice com SAUDI ARABIA 9200 21230 TURKEY 444 77 11 U A E 800 SAMSUNG 726 7864 QATAR 4450 4533 www techno blue com BAHRAIN 8000 4726 OMAN 800 SAMSUNG 726 7864 JORDAN 0800 22273 EGYPT 08000 726786 www samsung com MOROCCO 080 100 2255 KUWAIT 183 2255 NIGERIA 0800 SAMSUNG 726 7864 SOUTH AFRICA 0860 SAMSUNG 726 7864
13. 0 kPa and for burst pressure of at least 20700 kPa Under no circumstances must sanitary type copper pipe be used There are 2 refrigerant pipes of different diameters The smaller one is for the liquid refrigerant The larger one is for the gas refrigerant A short pipe is already fitted to the air conditioner You may need to extend the pipe using the assembly pipe optional mi The connection procedure for the refrigerant pipe varies ean Pa UA according to the exit position of the pipe when facing the wall i Right A Ud JB eLeft B sad kal e Underside C C e Rear 1 Cut out the appropriate knock out piece A B C on the rear of the indoor unit unless you connect the pipe directly from the rear r i i lt lt ou _ 06 35 mm 140 170 2 Smooth the cut edges 69 52 mm 250 280 612 70 mm 380 420 3 Remove the protection caps of the pipes and connect the assembly pipe 615 88 mm 440 480 to each pipe Tighten the nuts first with your hands and then with a torque wrench applying the following torque A Ifyou want to shorten or extend the pipes refer to page 31 32 NOTE 4 Cut off the remaining foam insulation 5 If necessary bend the pipe to fit along the bottom of the indoor unit Then pull it out through the appropriate hole b The pipe should not project from the rear of the indoor unit b The bending radius should be 100 mm or more 6 Pass the pipe th
14. 18xx downwards Pan eis cio cee Z CAUTION Make sure to drill only one hole after choosing the direction of Pipe hole the pipe 065mm lie 2 Fix the indoor unit C 120 If you fix the indoor unit on a wall 1 Fixthe installation plate to the wall giving attention to the weight of the indoor unit Unit a aa N _ If you mount the plate to a concrete wall using plastic Pipe hole anchors make sure that gaps between the wall and the plate 65mm created by projected anchor is less than 20mm Plastic Anchor If you fix the indoor unit on a window frame 1 Determine the positions of the wooden uprights to be attached to the window frame 2 Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit 3 Attach the installation plate to the wooden upright using tapping screws A Fix the installation plate without inclining to one side CAUTION 27 Connecting the assembly cable Cable specification Model Power cable Interconnection cable AS09 3G 1 0mm 3G 1 0mm AS12 18 3G 1 5MM 3G 1 5MM AS24 3G 2 5mm2 3G 2 5mm2 Connect the power cable to the auxiliary circuit breaker If every pole fails to connect to NOTE the power supply it must be incorporated in a wire with a contact opening of 53mm i Connecting the cable Electrical work 1 For electrical and earth works comply with the technical standards of electrical inst
15. ad 24 20 8 Make at least one round It will reduce noise and vibration The appearance of the unit may be different from the diagram depending on the model 24 Space Requirements for Outdoor Unit When installing 1 outdoor unit x Figure Description Air intake hir outlet Cl 4 Air flow direction When the air outlet is opposite the wall LION Uy 300 or more x The upper part of the outdoor unit and the air outlet is towards the wall 2000 or more _____ a 1500 or more When installing more than 1 outdoor unit m Z Q CU N I Air outlet 4 Air intake f Unit mm When the air outlet is towards the When 3 sides of the outdoor unit are wall blocked by the wall U o a v _ O O V z 3 5 mM S RA rm Li a gt q 150 or more 600 or more The upper part of the outdoor unit x When the walls are blocking front and the air outlet is opposite the and the rear side of the outdoor unit wall LAUL LU LALL L LGA S 300 or more U 5w F 18 5 mM o LO V 5 og ng Unit mm When the air outlet is towards the wall Y Uu Y ndi When 3 sides of the outdoor unit are blocked by the wall 300 or more 1500 or more a a Lagi 300 or more 6000rmore 6000rmore 600 or more 25 Choosing the installation location Unit mm x When the walls are blocking front and the rear side of the outdoor x
16. allations and the the wiring regulations of the Electricity Enterprises Act 2 Tighten the terminal block screw to under 12kgf cm 3 Precautions when connecting terminal blocks of the indoor unit gt Before connecting make sure the connecting part of the terminal socket is facing upwards The terminal socket There is no ring terminal Upside down is damaged to cover the wire b There must be no space between the terminal and the screw when connected Any remaining space may become a fire hazard due to overheating of the electrical contact The terminal socket Either the screw is not fitted properly is upside down or there is a space between the screw and the ring terminal A For the terminal block wiring use a wire with a ring terminal socket only CAUTION Regular wires without a ring terminal socket may become a fire hazard due to overheating of the electrical contact during a wiring work The outdoor unit is powered from the indoor unit through the assembly cable If the outdoor unit is more than 5 meters away from the indoor unit you must extend the cable The maximum length of the cable is 15 09 12 18 20 24 meters 1 Extend the assembly cable if necessary 2 Open the front grille 3 Remove the screw securing the connector cover 4 Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals as seen in the picture gt e Each wire is labeled wit
17. cal sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance FOR CLEANING WARNING O Do not clean the appliance by spraying water directly onto it Do not use benzene thinner or alcohol to clean the appliance gt This may result in discoloration deformation damage electric shock or fire Before cleaning or performing maintenance unplug the air conditioner from the wall socket and wait until the fan stops gt Failing to do so may result in electric shock or fire FOR CLEANING NCAUTION O Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges gt To avoid cutting your fingers wear thick cotton gloves when cleaning it Do not clean the inside of the air conditioner by yourself gt For cleaning inside the appliance contact your nearest service center gt When cleaning the internal filter refer to the descriptions in the Cleaning the air conditioner section gt Failure to do may result in damage electric shock or fire Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within Refer to the table for efficient use Mode Indoor temperature Ou
18. change in order of Auto Cool Dry and Fan a Fan gt Pat Press the button to set the desired fan speed Auto SH af Auto Cool SH af Auto Low Sg Med Sag High Dry SH 9 Auto Fan SH Low SP ag Med ng f High Heat SO af Auto Low Kng Med Sp High a e Press the button to adjust the temperature Auto You can adjust the desired temperature by 1 C within the range of 16 C 30 C Cool You can adjust the desired temperature by 1 C within the range of 16 C 30 C Dry You can adjust the desired temperature by 1 C within the range of 18 C 30 C Fan Temperature adjustment is not possible Heat You can adjust the desired temperature by 1 C within the range of 16 C 30 C Air flow can be adjusted manually see page 12 for instructions NOTE i Dry mode is only available in the cooling mode 11 Adjusting the air flow direction Air flow can be directed to your desired position i Vertical air flow Air flow blades move up and down Press the Air swing button on the remote controller gt Air swing indicator will be on and air flow blades move up and down continuously to circulate the air gt Press the Air swing button on the remote controller again to keep the air flow direction in a constant position 7 E Lot wat Horizontal air flow Make sure one of the blade pin lever that stick out of the air fl
19. d 2 Clean the fan 2 Verify that all the fan assembly is firmly tightened 2 Clean the condensate drain pan 2 This check mark requires checking the indoor outdoor unit periodically following to the description to maintain the air conditioner properly 1 The described operations should be performed more frequently if the area of installation is very dusty NOTE 2 These operations must always be performed by qualified personnel For more detailed information see the installation part in the manual 19 HSITON3 Troubleshooting Refer to the following chart if the air conditioner operates abnormally This may save time and unnecessary expenses PROBLEM SOLUTION The air conditioner does Check power status and then operate the air conditioner again not work at all e Plugin or switch on the circuit breaker and then operate the air conditioner again Check if you have set the Off Timer Operate the air conditioner again by pressing the Power button The temperature e Check if you have selected Fan Turbo mode In these modes desired temperature is set to adjustment is not working auto and you cannot adjust the temperature Cool Warm air does not come out of the air conditioner Check if the set temperature is higher during Cool mode lower during Heat mode than the current temperature Press the Temp or button on the remote controller to change the set temperature C
20. d hard floor that can support its weight gt Failing to do so may result in abnormal vibrations noise or problems with the product Install the draining hose properly so that water is drained correctly gt Failing to do so may result in water overflowing and property damage When installing the outdoor unit make sure to connect the draining hose so that draining is performed correctly gt The water generated during the heating operation by the outdoor unit may overflow and result in property damage In particular in winter if a block of ice falls it may result in injury death or property damage Safety precautions FOR POWER SUPPLY WARNING Q Remove all foreign substances such as dust or water from the power plug terminals and contact points using a dry cloth on a regular basis gt Unplug the power plug and clean it with a dry cloth gt Failing to do so may result in electric shock or fire Plug the power plug into the wall socket in the right direction so that the cord runs towards the floor gt Ifyou plug the power plug into the socket in the opposite direction the electric wires within the cable may be damaged and this may result in electric shock or fire When the appliance or power plug or power cord is damaged contact your nearest service center Plug the power plug into the wall socket firmly Do not use a damaged power plug damaged power cord or loose wall socket gt This may result in electric shock o
21. do not use the other drain hose hole block it with a rubber stopper NOTE 4 Pass the drain hose under the refrigerant pipe keeping the drain hose Shield tight 5 Pass the drain hose through the hole in the wall Check if it slants R 3 Drain hose Extension drain hose downwards as seenin the picture e The hose will be fixed permanently into position after finishing the installation and the gas leak test refer to page Note 37 for further details Make sure the installed direction of the drain hose is correct caution Inadequate installation may cause condensate water leakage If the drain hose is routed inside the room insulate the hose so that dripping condensation does not damage the furniture or floors e DO NOT WALL UP THE DRAIN HOSE CONNECTION Drain hose connection must be easy accessible and serviceable Changing direction of the drain hose Change the direction only when it is necessary eth Detach the rubber cap with the plier N Detach the drain hose by pulling it and turning to the left 3 Insert the drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan 4 Attach the rubber cap with a screwdriver by turning it to the right until it fixes to the end of the groove 5 Check for leakage on both side of the drain outlet N Pour the water in direction of arrow amp Direction of the drained water
22. electric shock fire explosion problems with the product or injury Install a switch and circuit breaker dedicated to the air conditioner gt Failing to do so may result in electric shock or fire Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed gt Failing to do so may result in electric shock or fire Do not install this appliance near a heater inflammable material Do not install this appliance in a humid oily or dusty location in a location exposed to direct sunlight and water rain drops Do not install this appliance in a location where gas may leak gt This may result in electric shock or fire Never install the outdoor unit in a location such as on a high external wall where it could fall gt Ifthe outdoor unit falls it may result in injury death or property damage This appliance must be properly grounded Do not ground the appliance to a gas pipe plastic water pipe or telephone line gt Failure to do so may result in electric shock fire an explosion or other problems with the product gt Never plug the power cord into a socket that is not grounded correctly and make sure that it is in accordance with local and national codes FOR INSTALLATION NCAUTION Q This appliance should be positioned in such a way that it is accessible to the power plug gt Failing to do so may result in electric shock or fire due to electric leakage Install your appliance on a level an
23. en the air conditioner is supplied without the assembly pipe as seen in the picture below NOTE 26 Optional accessories The following connection accessories are optional If they are not supplied you should obtain them before installing the air conditioner Insulated Insulated Assembly Insulated Assembly Pipe Insulated Assembly Pipe Assembly Pipe Pipe 09 52mm 1 612 70mm 1 015 88mm 1 PET3 Foam Tube Insulation 1 Vinyl Tapes 2 6 35mm 1 X 09 12 18 KDE a HSITON3 M4 x 25 Tapped Drain Hose Screws 6 length 2m 1 Putty 100g 1 amp 2 If these accessories are supplied they will be in the accessory box NOTE Fixing the installation plate You can select the direction of the drain hose depending on where you want to install the indoor unit Therefore before fixing the installation plate to a wall ora window frame you must determine the position of the 65mm hole through which Direction of pipe the cable pipe and hose pass to connect the indoor unit to the outdoor unit When facing the wall the pipe and cable can be connected from the e Right A e Left B e Underside_right C e Rear right or left D 1 Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly Unit mm 09 12xx xx
24. falls ocean surf rivers and mountains 1 Press the SPi button on the remote control SPi indicator will appears on the remote control display and the air conditioner generates SPi ot e The SPi mode can be selected whether the air conditioner is on off e The SPi mode will be on automatically when you turn on the air conditioner To deactivate SPi mode 1 Press the SPi button on the remote control SPi mode you set will be canceled 15 Using the Auto Clean function Auto clean function will prevent from growing mold by eliminating the moisture inside of the indoor unit Your indoor unit evaporates the moisture inside of the unit Activate this function to provide you with more clean and healthier air Press the Auto Clean button When the air conditioner is turned off Humi sleep Beep Off Display Off b The Auto clean indicator C1 on the indoor unit display appears and the Auto cleaning function runs When the air conditioner is turned on b The Auto clean indicator C1 on the indoor unit display appears and the Auto cleaning function runs after stopping the air conditioner operation x Auto Cleaning time can vary depending on the previously used mode Auto cool Cool Dry mode approximately 30 minutes Auto heat Heat Fan mode approximately 15 minutes Cancel Press the Auto Clean button once again When the air conditioner is turned on the Auto clean function runs after NOTE s
25. h the corresponding terminal number NOTE Pass the other end of the cable through the 65mm hole in the wall Close the connector cover tightening the screw carefully Close the front grille CONIA Uu Remove the terminal board cover on the side of the outdoor unit 28 9 Connect the cables to the terminals as seen in the picture B Each wire is labeled with the corresponding terminal number NOTE EDE a a eee h Indoor unit AS09 12 18 i l Indoor unit i l i l i l Outdoor unit l A 0a i Outdoor unit IK H i l l l l l Ground Wire i Green Yellow Ground Wire 80 Q Green ellow l Outdoor unit CE EA N ENE E 10 Connect the grounding conductor to the grounding terminals 11 Close the terminal board cover tightening the screw carefully 12 Connect the power cable to the indoor unit Connect the wires according to color codes referring to the wiring diagram The power cable and the interconnection cable should be selected according to the specification in page 28 WARNING HSITON3 Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field supplied copper pipes by means of flare connections Use insulated seamless refrigeration grade pipe only Cu DHP type according to ISO1337 degreased and deoxidized suitable for operating pressures of at least 420
26. he On and Off timer will be canceled and the indicator will disappear Using the Smart Saver function This function will set the temperature range limit to help you save energy while the air conditioner is operating in Cool mode Press the Smart Saver button on the remote controller while the air conditioner is oi operating in Cool mode md gt Smart Saver indicator and air swing indicator appears automatically on the remote aman an Coan controller display SN The air flow blades move up and down gt Ifthe current set temperature is lower than 24 C it will automatically raise to 24 C eal Cancel Press the Smart Saver button once again a SET qc Lt Bal Smart Saver function is only available in Cool mode When Smart Saver function is activated temperature range will be limited to 24 C 30 C If the desired temperature is lower than 24 C turn off the Smart Saver function by pressing the Smart Saver button again Temperature Fan speed can also be adjusted see page 11 for instructions Air flow can be adjusted manually see page 12 for instructions If you press the Mode button while the Smart Saver function is on it will cancel the function USING THE SPi FUNCTION lt FOR SPi MODEL gt SPi Super Plasma lon generates hydrogen H and oxygen O2 to remove a polluted substance and decomposition of such harmful particles It makes you breathe better as if you were staying around water
27. heck if the Air filter is blocked by dirt If there is a lot of dust on the Air filter cooling heating performance may decrease Clean them frequently Check if the outdoor unit is covered or installed near the obstacle Take the cover off and take the obstacle away If you want to operate the air conditioner in the sunlight cover the outdoor unit using curtains or etc Check if the air conditioner is operating in De ice mode When the ice formed in winter or the outdoor temperature is too low the air conditioner operates in De ice mode automatically In De ice mode indoor fan stops and cool air does not come out If the doors or windows are open it may cause bad cooling heating performance Close the doors and windows Check if the air conditioner has just been turned on after stopping cooling or heating operation In this case just a fan will run to protect the outdoor unit compressor Check if the pipe length is too long When the pipe length exceeds maximum allowable pipe length cooling heating performance may decrease Air flow adjustment is not working Check if you have selected Auto Dry good sleep mode In these modes desired temperature is set to auto and you cannot adjust the temperature Fan speed adjustment is not working Check if you have selected Auto Dry Turbo good sleep mode In these mode fan speed is set to Auto and you cannot adjust the fan speed Remote controller is not working Chec
28. hocks or fires Do not place containers with liquids or other objects on the unit All the materials used for the manufacture and packaging of the air conditioner are recyclable The packing material and exhaust batteries of the remote controller optional must be disposed of in accordance with current laws gt The air conditioner contains a refrigerant that has to be disposed of as special waste At the end of its life cycle the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely 22 Installing the unit IMPORTANT When installing the unit always remember to connect first the refrigerant tubes then the electrical lines gt Always disassemble the electric lines before the refrigerant tubes Upon receipt inspect the product to verify that it has not been damaged during transport If the product appears damaged DO NOT INSTALL it and immediately report the damage to the carrier or retailer if the installer or the authorized technician has collected the material from the retailer HSITON3 After completing the installation always carry out a functional test and provide the instructions on how to operate the air conditioner to the user Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires explosions or injuries To prevent injury when acciden
29. imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung com register PF DB98 34351A 3 ASO9E gt Series AS12E Series AS18E Series AS24E ex Series Features of your new air conditioner Contents Cool Summer Offer USING PARTS On those hot sweltering summer days and long restless Safety precautions unawaan aaananaanawaawsnnan m3 nights there is no better escape from the heat than the Checking before USE uu vu waaa 6 cool comforts of home Your new air conditioner brings an Checking the name of the parts seventeen 7 end to exhausting hot summer days and lets you rest Beat Checking the remote controller aan 8 the heat with your own air conditioner this summer a O sccescteessexsicecaceectzectexecec cient ec tah acer 10 Adjusting the air flow direction u s 12 Look for Everywhere Using the Turbo function aakalain 12 l o KA good sleep Mode aan mak The elegant and harmonious design gives priority Setting the On Off timer sss 14 to the esthetics of your space and complements any Using the Smart Saver function aan 15 of your existing interior d cor With its soft color and Using the SPi FUNCTION 15 rounded edge shape the new air conditioner adds class Using the Auto Clean function aan 16 to any room Enjoy what your air conditioner offers both Using the Filter Reset aaa 16 functionally and esthetical
30. k if your batteries are depleted Make sure nothing is blocking your remote controller sensor Check that there are strong lighting apparatus near the air conditioner Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves Timer function does not set Check if you press the Set Cancel button on the remote controller after you have set the time The indicator is blinking continuously Press the Power O button or disconnect the power plug switch off the auxiliary power switch If the indicator is still blinking contact the service center Odors permeate in the room during operation Check if the appliance is running in a smoky area Ventilate the room or operate the air conditioner in Fan mode for 1 2 hours We do not use smelly components in the air conditioner 20 PROBLEM SOLUTION Error is indicated Noise is generated e When an indoor unit indicator blinks contact the nearest service center e Depending on the status of the air conditioner usage noise can be heard when refrigerant flow movement changes It is normal Smoke is generated from the outdoor unit f may not bea fire but it can be a steam generated by the defrost operation from outdoor heat exchanger during Heat mode in winter Water is dropping from the outdoor unit piping connection Water may be generated because of the temperature difference It is normal 21
31. lems with the product water leakage electric shock or fire gt A delivery service for the product is not provided If you reinstall the product in another location additional construction expenses and an installation fee will be charged gt Especially when you wish to install the product in an unusual location such as in an industrial area or near the seaside where it is exposed to the salt in the air please contact your nearest service center Do not touch the power plug or the circuit breaker with wet hands gt This may result in electric shock Do not unplug the power plug or turn the air conditioner off with the circuit breaker while it is operating gt Plugging the power plug into the wall outlet or turning the air conditioner on from the circuit breaker may cause a spark and result in electric shock or fire After unpacking the air conditioner keep all packaging materials well out of the reach of children as packaging materials can be dangerous to children gt Ifa child places a bag over its head it may result in suffocation Do not insert your fingers or foreign substances into the outlet when the air conditioner is operating gt Take special care that children do not injure themselves by inserting their fingers into the product Do not touch the air flow blade with your hands or fingers during the heating operation gt This may result in electric shock or burns Do not insert your fingers or foreign substances int
32. lling the unit close to a neighbor If you install the outdoor unit in a place exposed to strong winds or at a height fix it to an appropriate support wall or ground gt JJ 1 Place the outdoor unit as indicated on the top of the unit to let the discharged air out Rubber leg properly Model x v 2 Fixthe outdoor unit in level to an appropriate support using anchor bolts 3 If the outdoor unit is exposed to strong winds install shield plates around the outdoor unit so that the fan can operate correctly Secure the rubber leg to prevent the generation of noise and vibration NOTE 37 Final Check and Trial Operation To complete the installation perform the following checks and tests to ensure that the air conditioner operates correctly EO Soe Mode Check the followings 3 I e Strength of the installation site gt Smart f Turbo Quiet e Tightness of pipe connection to detect gas leak am BIN ao e Electric wiring connection bo kiya HE e Heat resistant insulation of the pipe oat Temp Fan g Saver Turbo Quiet d light e Drainage J catty e Grounding conductor connection f Lk f IPA e Correct operation follow the steps below 1 Press the Power button and check the follo
33. ly Cleaning the air conditioner 17 P Maintaining the air conditioner u aaa 19 good sleep function THROU NESE ORIG aaa ma 20 good sleep function allows you to set a comfortable sleep temperature while saving energy and having sound INSTALLATION PARTS sleep Safety PONE C ULI OMS sissien 22 Choosing the installation location eeseesesssssecccsccsecsessenen 23 ACCESSONIES amma paha haaa kai 20 FIXING the installation plate anas 27 Connecting the assembly cable nanasa 28 Installing and connecting the assembly DIE OF THE INdO0 UNE mamana 30 Purging the indoor Unit sccsnanesinaniernestemninniane 31 Cutting or extending the Pipe s ssssssssssssesssesesseeoseossessoseeeeee 31 Installing and connecting the drain hose of the indoor unit ssssssssssccsesssssseeeesesssesesssue 32 Changing direction of the drain hose wessssssssssssseseesessun 33 Purging the connected pipes sssssscccseccseecssssnssssssssssseue 34 Performing the gas leak tests Ulan 36 FIXING the indoor unit in place ou anan 37 Fixing the outdoor unit in place eeeessssssssssssssssssssssssseseeen 37 Final check and trial operation sesesssssscscsssssssssssscccessessen 38 Pump down procedure when removing the product aasa 38 How to connect your extended power cables 39 USING PARTS Safety precautions Before using your new air conditioner please read this manual thoroughly to ensure that you know how to safely and efficien
34. o the air inlet outlet of the air conditioner gt Take special care that children do not injure themselves by inserting their fingers into the product Do not strike or pull the air conditioner with excessive force gt This may result in fire injury or problems with the product FOR USING AMWARNING O Do not place an object near the outdoor unit that allows children to climb onto the machine gt This may result in children seriously injuring themselves Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people gt Since this may be dangerous due to a lack of oxygen Open a window at least once an hour HSITON3 If any foreign substance such as water has entered the appliance cut the power by unplugging the power plug and turning the circuit breaker off and then contact your nearest service center gt Failing to do so may result in electric shock or fire Do not attempt to repair disassemble or modify the appliance yourself gt Do not use any fuse such as cooper steel wire etc other than the standard fuse gt Failing to do so may result in electric shock fire problems with the product or injury FOR USING NCAUTION Q O Do not place objects or devices under the indoor unit gt Water dripping from the indoor unit may result in fire or property damage Check that the installation frame of the outdoor unit is not broken at least once a year gt
35. ofessional installation agency for product installation 35 HSITON3 Performing the gas leak tests Make sure to check for gas leaks before completing the installation process connecting the assembly pipe and hose between indoor unit and outdoor unit insulating the cables hose and pipe and fixing the indoor unit to the installation plate To check for gas leaks on the outdoor unit Check the valve A and B using a leak detector To check for gas leaks on the indoor unit Check the flare nut C and D using a leak detector 36 Leak test with nitrogen before opening valves In order to detect basic refrigerant leaks before recreating the vacuum and recirculating Leak test after opening valves Before opening valves discharge all the nitrogen from the system and create vacuum according to page 34 35 After opening valves check leaks using a leak detector for refrigerant Pump down before disconnecting the refrigerant connections for unit repair removal or disposal Pump down is an operation intended to collect all the system refrigerant in the outdoor unit This operation must be carried out before disconnecting the refrigerant tubing in order to avoid refrigerant loss to the atmosphere gt Shut off the liquid valve with the Allen wrench gt Turn the system on in cooling with fan operating at high velocity Compressor will immediately start provided 3 minutes have elapsed since the last stop gt
36. op of the front panel and pull it down to open Then slightly lift the panel up HSITON3 SOCOM KKK x P9292829 ISSCC KOS KIS Heat exchanger Illustration may differ slightly depending on the models 17 Cleaning the air conditioner Removing the Air filter Grab the handle and lift it up Then pull the Air filter towards you and slide it down Cleaning the air filter Washable foam based air filter captures large particles from the air The filter is cleaned with a vacuum or by hand washing Open the panel and put the Air filter out Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy rinse it with running water Insert the Air filter back in its original position Dry the Air filter in a ventilated area and close the front panel Clean the Air filter every 2 weeks or when the filter clean reminder lights up Cleaning term may differ depending on the usage and environmental conditions In dusty area clean it once a week When the filter clean reminder is on
37. ow blades are not broken Move the blade pin lever left or right to keep the air flow direction in a constant position you prefer Be extremely careful with your fingers while adjusting the Horizontal air flow direction There is a potential risk of personal injury when the unit is mishandled Using the Turbo function Turbo function will be helpful to cool your room quickly and effectively Press the Turbo button on the remote controller during Cool mode aa aa b Turbo indicator appears on the remote controller display and the air conditioner Saver Turbo Quiet i Saver N operates in Turbo function for 30 minutes Cancel Press the Turbo button once again Turbo function is only available in Cool mode NOTE Ifyou press the Mode button while the Turbo function is on it will cancel the function e Temperature Fan speed cannot be adjusted while using this function 12 good sleepmode For a comfortable sleep the air conditioner will operate it Fall asleep gt Sound sleep gt Wake up from good sleep mode When the air conditioner is on and in cool heat mode 1 Press the good sleep button on the remote controller gt good sleep indicator appears and Off timer indicator starts blinking on the remote LAA controller display HSITON3 panaman RN 2 Press the good sleep button to set the time KB E gt You can set the time in half hourly unit from 30 minu
38. please press FILTER RESET button on remote controller The filter clean reminder is optional function This function differs depending on the model If the Air filter dries in a confined or humid area odors may generate If it occurs re clean and dry it in a well ventilated area 18 Maintaining the air conditioner If the air conditioner will not be used for an extended period of time dry the air conditioner to maintain it in best condition 1 Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug There may be internal damage if moisture is left in components 2 Before using the air conditioner again dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours This helps remove odors which may have generated from dampness Periodical checks Refer to the following chart to maintain the air conditioner properly Every 2 Every 3 Every 4 Type Description eek onh month Once a year Clean the air filter 1 Clean the condensate drain pan 2 Indoor nit Thoroughly clean the heat exchanger 2 Clean the condensate drain pipe 2 Replace the remote controller batteries 1 Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric components with jets of air 2 Outdoor Verify that all the electric components are firmly unit tightene
39. r fire Do not pull the power cord when unplugging the power plug gt Unplug the power plug by holding the plug gt Failing to do so may result in electric shock or fire Do not pull or excessively bend the power cord Do not twist or tie the power cord Do not hook the power cord over a metal object place a heavy object on the power cord insert the power cord between objects or push the power cord into the space behind the appliance gt This may result in electric shock or fire FOR POWER SUPPLY CAUTION When not using the air conditioner for a long period of time or during a thunder lightning storm cut the power at the circuit breaker gt Failing to do so may result in electric shock or fire FOR USING AMWARNING If the appliance is flooded please contact your nearest service center gt Failing to do so may result in electric shock or fire If the appliance generates a strange noise a burning smell or smoke unplug the power plug immediately and contact your nearest service center gt Failing to do so may result in electric shock or fire In the event of a gas leak such as propane gas LP gas etc ventilate immediately without touching the power plug Do not touch the appliance or power cord gt Do not use a ventilating fan gt A spark may result in an explosion or fire To reinstall the air conditioner please contact your nearest service center gt Failing to do so may result in prob
40. r room You can adjust the temperature and the fan speed to feel cooler in hot season If current outside temperatures are much higher than the selected indoor temperature it may take time to bring the inner temperature to the desired coolness Dry The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air Dry mode makes the air feel refreshing in a humid climate To activate the Dry mode remote set temperature must be lower than indoor room temperature Fan Fan mode can be selected to ventilate your room Fan mode will be helpful to refresh the stale air in your room a Heat The air conditioner heats as well as cools Warm your room with this versatile appliance in the cold of winter 10 Fan may not operate for about 3 5 minutes at the beginning to prevent any cold blasts while the air conditioner is warming up Since the air conditioner heats the room by taking heat energy from outdoor air the heating capacity may decrease when outdoor temperature is extremely low Use an additional heating appliance in combination with the air conditioner if you feel the air conditioner heats insufficiently Only Heating models have this function model AQ09 12 18 24 Xx Series Press the button to turn on the air conditioner Press the button to set the operating mode m Each time you press the Mode button the mode will
41. rclockwise Valve 5 Purge the air in the connected pipes using the vacuum pump for about 15 minutes Gas service port lt Low pressure gt gt Make sure that pressure gauge shows 0 1MPa 76cmHg after about 10 minutes This procedure is very important to avoid a gas leak gt Close the valve of the low pressure side of manifold gauge clockwise gt Turn off the vacuum pump Vacuum gt Check for 2 minutes if there is any pressure change Liquid service port ons lt High pressure gt Backward flowing gt Remove the hose of the low pressure side of manifold gauge prevention 6 Seta valve cork of liquid and gas service port to the open position 7 Mount the valve stem nuts and the service port cap to the valve and tighten them at the torque of 183kgf cm with a torque wrench Valve stem 8 Check for a gas leak paying particular attention to the 3 way valve s stem nuts and to the service port cap Refer to page 36 or liquid 34 Adding Refrigerant Add refrigerant charge according to table below If you use a pipe longer than 5m Model o A Ag of refrigerant must be added for each extra meter I you use a pipe shorter than 5m The purge time is normal Refer to the Service Manual for further details The remaining air in the Refrigeration cycle which contains moisture may cause malfunction on the compressor caution Always contact the service center or a pr
42. ressure side 5 Stop operation of the air conditioner 6 Disconnect the pipes 38 How to connect your extended power cables Items to prepare compressor and insulation tape should be prepared by an installation technician Crimping plier Connection sleeve mm Insulation tape Contraction tube mm 20x7 0 HxOD Width 18mm 50x 8 0 LxOD 1 As shown in the figure peel off the shields from the rubber wire Unit mm of the power cable Power cable provided by us Peel off 20 mm of the wire shields of the tube installed already A After peeling off the tube wire you must insert a contraction tube CAUTION 2 Insert both sides of core wire of the power cable into the connection sleeve Connection sleeve 3 Using a compressor compress the two points and flip it over and compress another two points in the same location The compression dimension should be 8 0 After compressing it pull both sides of the wire to make sure it is firmly pressed 4 Wrap it with the insulation tape twice and position your Insulation tape contraction tube in the middle of the insulation tape a 5 Apply heat to the contraction tube to contract it 40mm _ tube 6 After tube contraction work is completed wrap it with the Insulation tape insulation tape to finish a Incase of extending the electric wire please DO NOT use a round shaped pressing socket A Incomplete wire connections can cause electric
43. rough the hole in the wall 7 For further details on how to connect to the outdoor unit and purge the air refer to page 34 35 The pipe will be insulated and fixed permanently into position after finishing the installation and the gas leak test Note referto page 37 for further details A Tighten the flare nut with torque wrench according to specified method caution __ the flare nut is over tightened the flare may break and cause refrigerant gas leakage e DO NOT WALL UP THE PIPE CONNECTION All refrigerant pipe connection must be easy accessible and serviceable 30 Purging the indoor unit The indoor unit is supplied with inert gas nitrogen Before installing the unit check if nitrogen gas flow out of indoor unit If this one isn t true DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit 1 Unscrew the caps at the end of each pipe gt All inert gas exhausts from the indoor unit To prevent dirt or foreign substances from getting into the pipes during Note installation do NOT remove the caps completely until you are ready to connect the pipes The remaining air in the Refrigeration cycle which contains moisture caution May cause malfunction on the compressor e Always contact the service center or a professional installation agency for product installation Cutting or extending the pipe A 5 meter pipe is supplied with the air conditioner optional NOT
44. suitably dimensioned Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram included in the manual Always verify that electric connections cable entry section of leads protections are compliant with the electric specifications and with the instructions provided in the wiring scheme Always verify that all connections comply with the standards applicable to the installation of air conditioners Choosing the installation location Indoor unit gt gt gt vv vV VvV V Where airflow is not blocked Where cool air can be distributed throughout the room Install the refrigerant piping length and the height difference of both indoor and outdoor units as indicated in the installation diagram Wall that prevents vibration and is strong enough to hold the product weight Out of the direct sunlight 1m or more away from the TV or radio to prevent the screen from being distorted or noise from being generated As far away as possible from the fluorescent and incandescent lights so that the remote controller can be operated well A place where the air filter can be replaced easily 23 Choosing the installation location i Outdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Out of the direct sunlight and rain Where neighbors are not annoyed by operation sound or hot air Solid wall or support that prevents vibra
45. tally touching the indoor unit fan install the indoor unit at least 2 5m above the floor The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs The units components must be accessible and that can be disassembled in conditions of complete safety either for people or things For this reason where it is not observed as indicated into the Installation Manual the cost necessary to reach and repair the unit in safety as required by current regulations in force with slings trucks scaffolding or any other means of elevation won t be considered in warranty and charged to end user Power supply line fuse or circuit breaker gt Always make sure that the power supply is compliant with current safety standards Always install the air conditioner in compliance with current local safety standards Always verify that a suitable grounding connection is available Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines Always verify that the cut off and protection switches are
46. tdoor temperature Indoor humidity Cooling 16 C 32 C 15 C 43 C Relative humidity 80 or less Dry 18 C 32 C 15 C 43 C gt If the air conditioner operates in cooling mode for long period of time in high humidity area dew may be formed l Maintaining your air conditioner Internal protections via the unit control system gt This internal protection operates if an internal fault occurs in the air conditioner Type Description Against cold air Theinternal fan will be off to against cold air when the heat pump is heating De ice cycle Theinternal fan will be off to against cold air when the heat pump is heating The air conditioner does not start operating immediately to protect the compressor of Protect compressor the outdoor unit after it has been started Ifthe heat pump is operating in Heat mode De ice cycle is actuated to remove frost from an outdoor unit that may NoTE have deposited at low temperatures The internal fan is switched off automatically and restarted only after the de ice cycle is completed Checking the name of the parts Your air conditioner may slightly look different from illustration shown below depending on your model Main parts Room temperature sensor Air filter under the oe Z Air intake a E AS Be Cape te LEE x AG PING spots aa ee Air flow blade HI ko n aaya s eae
47. tes 3 hours and hour unit from mer Imer U Cancel E oo 3 hours 12 hours Filter Reset Beep Off Display i amp E Clean Humi sleep S gt Operating hour can be set from minimum 30 minutes to maximum 12 hours gt Default operation hour is set to 8 hours 3 PresstheSet Cancel button to active it on gt Off timer indicator stops blinking and reserved time will be displayed for 3 seconds Then the air conditioner operates in good sleep Cool mode gt If you don t press Set Cancel button within 10 seconds after pressing the good sleep the air conditioner will return to previous status Check Off timer indicator and D indicator on the indoor unit Cancel Press the Set Cancel button once again Temp You can set the desired temperature by 1 C in the range of 16 C 30 C E Fan speed will be adjusted automatically according to the good sleep Fan mode v However If you select good sleep mode while heating operation is on you can adjust fan speed Air flow direction will be adjusted automatically according to the good sleep mode However If you select good sleep mode while heating operation is on you can adjust air flow direction Temperature and fan speed changes in good sleep mode Fall asleep Eases you into sleep by dropping the temperature Sound sleep Relaxes your body and raises your temperature slightly Wake up from good sleep mode Allows yo
48. tion and is strong enough to hold the product weight Where there is no risk of flammable gas leakage When installing the unit at a high place be sure to fix the unit legs 3m or more away from the TV or radio to prevent the screen from being distorted or noise from being generated Install the unit horizontally Place where drained water does not become any problem Place with no plants especially climbing plants and where small animal can not access vY YV YV vV V V V V V V A Avoid the following places to prevent malfunction of the unit caution Where there is machine oil Salty environment such as seaside areas Where sulfide gas exists Other special atmosphere areas Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner aaa 300mm or more a 125mm sa BEE SSL 125mm or more oma f or more j0 o leo 5 o LAST Chen es OS Wrap the refrigerant pipes and the drain hose with the absorbent pad and vinyl tape Refer to page 37 for further details lt You can select the direction of draining left or right LE mas maximum pipe length and 3 mas minimum pipe length CAUTION It will reduce noise and vibration H meters maximum total L meters maximum pipe height 600mm total pipe length minimum 300mm minimum SS Model L H 09 15 7 K12 15 7 600mm Sh A18 15 7 minimum
49. tly operate the extensive features and functions of your new appliance Because the following operating instructions cover various models the characteristics of your air conditioner may differ slightly from those described in this manual If you have any questions call your nearest contact center or find help and information online at www samsung com Important safety symbols and precautions HSITON3 A WARNING Hazards or unsafe practices that may result in severe personal injury or death AN CAUTION Hazards or unsafe practices that may result in minor personal injury or property damage rn a Unplug the power plug from the O Follow directions ua len ekek S Do NOT attempt Q Do NOT disassemble Make sure the machine is grounded to prevent electric shock FOR INSTALLATION WARNING Q O D Plug the power cord into a wall socket with the power specifications of the product or higher and use the socket for this appliance only In addition do not use an extension cord gt Sharing a wall socket with other appliances using a power strip or extending the power cord may result in electric shock or fire gt Do not use an electric transformer It may result in electric shock or fire gt Ifthe voltage frequency rated current condition is different it may cause fire The installation of this appliance must be performed by a qualified technician or service company gt Failing to do so may result in
50. topping the air conditioner operation USING THE FILTER RESET The Filter clean reminder will light up on the indoor unit display to notify you that the filter needs cleaning After cleaning filter press Filter Reset button to reset the Filter clean reminder Filter clean reminder will be turned off Beep Off Display Off On Off Set Timer Timer Cancel Gr Cleaning the air conditioner Make sure the power is turned off and unplugged from cauron the wall socket when cleaning the air conditioner Cleaning the indoor unit b Wipe the surface of the unit with a slightly wet or dry cloth when needed Contact the service center when you clean the indoor unit Note heat exchanger because it needs to be disassembled Do not clean the display using alkaline detergent caution Do not use Benzene Thinner or Clorox They may damage the surface of the air conditioner and can create a risk of fire Cleaning the outdoor unit heat exchanger gt When dust accumulates on the heat exchanger it may decrease cooling performance Therefore clean it regularly gt Spray water to clean the dust e If itis difficult to clean the outdoor unit heat exchanger on NoTE your own contact service center A Be careful with the sharp edges on the outdoor unit heat canon Exchanger Opening the panel Tightly grab t
51. u to wake up from comfortable intermittent air and it makes you feel refreshed Set Off timer in good sleep mode over 5 hours You fell disturbed sleep if the good sleep is set too short or long Nore because the default is set to 8 hour operation Ifthe good sleep mode is set less than 4 hours the operation will stop at the same time If the good sleep mode is set over 5 hours it will run as Wake up stage from the last one hour before it stops e Recommended set temperature is between 25 C 27 C for cooling and 21 C 23 C for heating 13 Setting the On Off timer You can set the air conditioner to turn on off automatically at desired time Setting On timer while the air conditioner is off Off timer while the air conditioner is on 1 Pressthe On Timer Off Timer button gt On Off timer indicator will blink on the remote controller display Setting On timer 2 Pressthe OnTimer Off Timer button to set the time gt You can set the time in half hourly unit from 30 minutes 3 hours and hour unit from 3 hours 24 hours Ge 0 S b Operating hour can be set from minimum 30 minutes to maximum 24 hours 3 Pressthe Set Cancel button to active it on b On timer indicator stops blinking and reserved time will be displayed for 3 seconds z z gt Ifyou don t press Set Cancel button within 10 seconds after selecting the time the air Setting Off timer conditioner will
52. wing b The indicator on the indoor unit lights up gt The airflow blade opens and the fan gears up for operation 2 Press the Mode button to select Cool or Heat mode gt In Cool mode use Temp or button and set the temperature at 16 C gt In Heat mode use Temp or button and set the temperature at 30 C Approximately 3 5 minutes later outdoor unit will start to operate and the Cool or Warm air will blow out NOTE After 12 minutes of stationary condition check the indoor unit air treatment Cooling mode indoor unit check gt Inlet air temp Outlet air temp From 10 C to 12 C indicative delta T Heating mode indoor unit check gt Outlet air temp Inlet air temp From 11 C to 14 C indicative delta T In heating mode the indoor fan motor can remain off to avoid cold air blown into conditioned space 3 Press the Air swing 5 button and check the following gt The airflow blades work properly 4 Press the Power button to stop the operation e When you complete the installation successfully hand over this manual to the user for storage in a handy and safe NOTE place Pump down procedure when removing the product 1 Turn on the air conditioner and select Cool mode to run the compressor for 3 minutes 2 Release the valve caps on High and Low pressure side 3 UseL wrench to close the valve on the high pressure side 4 Approximately 2 minutes after close the valve on the low p
53. y inside of the indoor Set theasd al d H good sleep mode on unit to get rid of odor Filter Reset Beep O Off Display C Off Filter Reset Reset the Filter Clean reminder Beep off To silence the beep sound when pressing the button Display off To turn off the display light On Timer Set the On Timer on Use 2nd function Temp Humi Set Cancel Set Cancel the timer good sleep mode Off Timer Set the Off Timer on The Temp Humi function is not available for this model When you press 2 F button the indicator will be displayed on the remote controller and you can change note the functions on the remote controller as listed below Auto Clean gt Filter Reset Temp Humi Beep Off good sleep Display Off function If you select the function under the button while the function of the button is switched by 2 4F button the 2 F function is canceled A Make sure that the water does not get to the remote controller e The Quiet function is not available for this model If you press the Quiet button in the cooling mode air conditioner will be operated as auto mode CAUTION Remote controller display Turbo indicator SPi indicator Quiet indicator Smart Saver indicator Use 2 nd function indicator On Timer indicator Off Timer indicator good sleep indicator Battery changing time Operation mode indicator Low battery indicator Transmit indicator Air swing indicator