Home

Samsung MH020FNEA User Manual

image

Contents

1. OPERATIONAL TEMPERATURE MODE INDOOR HUMIDITY IF OUT OF CONDITIONS INDOOR OUTDOOR Condensation may occur on COOLING 16 Cto320 5Cto43 ass AA n either water blow off or drops on the floor HEATING 27 C or less 15 C to 24 C f Internal protection triggers and the air conditioner will stop Condensation may occur on DRYING 16 C to 32 C 5 C to 43 C f the indoor unit with risk to have either water blow off or drops on the floor The standardized temperature for heating is 7 C If the outdoor temperature drops to O C or below the heating capacity can be reduced depending on the temperature condition If the cooling operation is used at over 32 C indoor temperature it does not cool at its full capacity 32_ appendix ENGLISH memo _33 QUESTIONS OR COMMENTS COUNTRY CALL ORVISITUS ONLINE AT COUNTRY CALL ORVISITUS ONLINE AT AUSTRIA 0810 SAMSUNG 7267864 0 07 min www samsung com www samsung com ua Ukrainian UKRAINE 0 800 502 000 i www samsung com be Dutch www samsung com ua_ru Russian BELGIUM 02 201 24 18 www samsung com be_fr French MOLDOVA 0 800 614 40 www samsung com BOSNIA 051 133 1999 www samsung com U A E 800 SAMSUNG 726 7864 www samsung com
2. Y When you press the Fan Speed c amp y button fan speed will change in order of Auto Low Medium and High Y e When you are using the remote control make sure correct indicator which matches your selection appears on the remote control display e Air flow can be adjusted manually See page 19 for instructions e If current outside temperatures are much higher than the selected indoor temperature it may take time to bring the inner temperature to the desired coolness operating _15 operating basic tunction SELECTING OPERATION MODE Dry The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air Dry mode makes the air feel refreshing in a humid climate 1 Turn on the air conditioner Press the Power amp Set Cancel button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Dry mode indicator appears on the remote control display The air conditioner operates in Dry mode and automatically adjusts the fan speed to Auto 7 When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the temperature Press the Temperature A or V button on the remote control to increase or decrease the desired temperature You can set the desired temperature between the range of 18 C 30 C You can increase decrease the temperature by 1 C 64 e When you are using the r
3. Y 12 viewing HE Mode a Temperature AV S Increase decrease the temperature by 1 C a Fan speed 4 Teer 5 good sleep Adjust how much air flows through the air conditioner with the 4 different fan speeds such as Auto Z Low Medium High On Time On timer D Set the on timer on Off Timer Adjust the time for On timer Cp Off timer Cancel Set the off timer on D Adjust the time for Off timer Turn on off the air conditioner and set cancel the timer function Each time you press the button a short beep will sound and a transmit indicator appears on the remote control display Remote control display Transmit indicator HAN kA Operation mode indicator Ga Laon pago Set temperature indicator ar Ere JD O Heat Turbo indicator HSITONA e Fan speed indicator 2t ir swing indi 5 Aut Air swing indicator E 291 Auto a Low On Timer indicator T ea Medium A Full High good sleep Off Timer StI Turbo indicator yt LI br Low battery indicator Using the remote control e Point the remote control towards the remote control sensor of the unit e When properly pressing the button on the remote control you will hear beep sound from the unit Y e The signal may not be received well of electronic lighting style fluorescent lamps such as inverter fluorescent lamps are in the same space e f other electrical products operate by
4. air flow it may cause unit malfunction or poor performance Make sure there are no obstacles under the indoor unit e Potential risk of fire or loss of property The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs The units components must be accessible and that can be disassembled in conditions of complete safety either for people or things For this reason where it is not observed as indicated into the Installation Manual the cost necessary to reach and repair the unit Ed safety as required by current regulations in force with slings trucks scaffolding or any other means ol yaon won t be considered in warranty and charged o end user neure Ai off on and protection switches are properly installed Do not use the air conditioner if damaged If problems occur immediately stop operation and cut off the power supply When not using the air conditioner for a long period of time or during a thunder lightning storm cut the power at the circuit breaker Call Lala place of purchase or a contact center if repairs are needed e Potential risk of fire or electric shock if disassembly or repairs are attempted by a non
5. 678 www samsung com GUATEMALA 1 800 299 0013 www samsung com latin en English SWEDEN 0771 726 7864 SAMSUNG www samsung com gt F HONDURAS 30077910267 www samsung com latin Spanish www samsung com ch German 4 P j SWITZERLAND 0848 SAMSUNG 7267864 CHF 0 08 min 1 pi y l vewwsamsung com atin_en English wvv samsung comic Frendi JAMAICA 1 800 234 7267 www samsung com U K 0330 SAMSUNG 7267864 www samsung com o 7 www samsung com latin Spanish EIRE 0818 717100 www samsung com NICARAGUA 00 1800 5077267 vewwisamsung com latin_en English LITHUANIA 8 800 77777 www samsung com It wwwsamsung com latin Spanish LATVIA 8000 7267 www samsung com lv PANAMA 800 7267 www samsung com latin_en English ESTONIA 800 7267 www samsung com ee 0 800 777 08 RUSSIA 8 800 555 55 55 www samsung com PERU Desde celulares por favor llamar al n mero www samsung com pe GEORGIA 0 800 555 555 www samsung com 3308986 PUERTO RICO 1 800 682 3180 www samsung com ARMENIA 0 800 05 555 www samsung com TRINIDAD amp AZERBAIJAN 088 55 55 555 www samsung com TOBAGO 1 800 SAMSUNG 726 7864 MWwW Samnsung com KAZAKHSTAN 8 10 800 500 55 500 GSM 7799 www samsung com VENEZUELA 0 800 100 5303 www samsung com ve UZBEKISTAN 8 10 800 500 55 500 www samsung com AUSTRALIA 1300 362 603 www samsung com au KYRGYZSTAN 00 800 500 55 500 www samsung com 1 800 10 7267864 PLDT TADJIKISTAN 8 10 800 500 55 500 www samsung com PHILIPPINES 1 800 8 7267864 Globe landline an
6. BULGARIA 07001 33 11 share cost tariff www samsung com bg www samsung com ae English OMAN 800 SAMSUNG 726 7864 i CROATIA 062 SAMSUNG 062 726 786 www samsung com hr www samsung com ae_ar Arabic CZECH 800 SAMSUNG 800 726786 www samsung com KUWAIT 183 2255 183 CALL www samsung com ae English DENMARK 70701970 www samsung com www samsung com ae_ar Arabic FINLAND 030 6227 515 www samsung com BAHRAIN 8000 4726 www samsung com ae English www samsung com ae_ar Arabic FRANCE 01 48 63 00 00 www samsung com fr p www samsung com ae English 0180 6 SAMSUNG bzw QATAR 800 2255 800 CALL f www samsung com ae_ar Arabic 0180 6 7267864 EGYPT 08000 726786 www samsung com HHP 0180 6 M SAMSUNG bzw GERMANY www samsung com 800 22273 www samsung com 0180 6 67267864 JORDAN y 065777444 Levant English 0 20 Anruf aus dem dt Festnetz aus i www samsung com dem Mobilfunk max 0 60 Anruf SYRIA 18252273 Levant English CYPRUS 8009 4000 only from landline www samsung com gr IRAN 021 8255 www samsung com 80111 SAMSUNG 80111 726 7864 only from land line GREECE o www samsung com gr MOROCCO 080 100 2255 www samsung com 30 210 6897691 from mobile and land line SAUDI ARABIA 9200 21230 www samsung com sa Arabic http www samsung HUNGARY 06 80 SAMSUNG 726 7864 TURKEY 44477 11 www samsung com com hu 800 SAMSUNG 726 7864 ARGENTINE 0800 333 3733 www samsung com ar ITALIA www samsung com HHP 800 Msamsung 800 67267864 URUG
7. installed in an inverted position it will not affect its filtration system 28_ cleaning and maintaining MAINTAINING YOUR AIR CONDITIONER If the air conditioner will not be used for an extended period of time dry the air conditioner to maintain it in best condition 1 Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and cut off the power supply There may be internal damage if moisture is left in components 2 Before using the air conditioner again dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours This helps remove odors which may have generated from dampness Periodical checks Refer to the following chart to maintain the air conditioner properly HSITONA Type Description Monthly yerd cos Clean the air filter 1 O Clean the condensate drain pan 2 O Indoor unit Thoroughly clean the heat exchanger 2 Clean the condensate drain pipe 2 e Replace the remote control batteries 1 O Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric components with jets of e air 2 Outdoorunit Verify that all the electric components are e firmly tightened 2 Clean the fan 2 O Verify that all the fan assembly is firmly e tightened 2 Clean the condensate drain pan 2 The checks and maintenance operation
8. qualified service technician 08 safety information contents VIEWING YOUR AIR CONDITIONER OPERATING BASIC FUNCTION USING ADVANCED FUNCTIONS CLEANING AND MAINTAINING THE AIR CONDITIONER APPENDIX 10 10 10 11 11 12 13 13 13 14 14 14 15 16 17 18 19 19 19 20 21 21 22 23 24 26 26 26 27 28 28 29 29 30 31 32 Checking the indoor unit and digital display Main parts Display Removing the front panel Power button and Room temperature sensor Checking the remote control Remote control display Using the remote control Installing the batteries HSITONA Turning the air conditioner on and off Selecting operation mode Auto Cool Dry Fan Heat Adjusting the air flow direction Vertical air flow Horizontal air flow Using the Turbo function Setting timer On timer Off timer Combining On timer and Off timer good sleep mode Cleaning the exterior Cleaning the filter Air filter Bio filter Replacing the filter Deodorizing filter Maintaining your air conditioner Periodical checks Internal protections via the unit control system Troubleshooting Operation ranges This product has been determined to be in compliance with the Low Voltage Directive 2006 95 EC and the Electromagnetic Compatibility Directive 2004 108 EC of the European Union pa a Applicable in countries with separate collection systems Correct Disposal of This Product Waste Electrical amp Electronic Equip
9. the remote control call your nearest contact center Installing the batteries 1 Slide the cover on the 2 Install two AAA batteries 3 Close the cover by sliding it rear side of the remote Check and match the and _ back to its original position control down to open gt signs accordingly Make You should hear click sound sure you have installed the when the cover is locked batteries in correct position properly Correct disposal of batteries in this product Applicable in countries with separate collection systems This marking on the battery manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life Where marked the chemical symbols Hg Cd or Pb indicate that the battery contains mercury cadmium or lead above the reference levels in EC Directive 2006 66 If batteries are not properly disposed of these substances can cause harm to human health or the environment To protect natural resources and to promote material reuse please separate batteries from other types of waste and recycle them through your local free battery return system viewing _13 operating basic function TURNING THE AIR CONDITIONER ON AND OFF Press the Power amp Set Cancel button on the remote control You will hear a ringing sound and the air flow blade will move up and down automatically when th
10. RE WARNING SIGNS N Do not place the air conditioner near hazardous substances or equipment that releases free flames to avoid fire explosions or injuries e Potential risk of fire hazard or explosion Do not install the outdoor unit at an unstable place or elevated surface where there is potential risk of falling e f the outdoor unit falls it may cause personal injury or loss of property Failure or damage may occur if any changes or modification that is not stated in the installation manual was performed In this case user will be responsible for the repair expenses Install the air conditioner away from direct exposure to sunlight heating apparatus and humid places e Hang curtains on windows to boost cooling efficiency and to avoid the risk of electric shock Use the power line with the power specifications of the product or higher and use the power line for this appliance only In addition do not use an extension line e Extending the power line may result in electric shock or fire Install an exclusive circuit breaker and short circuit breaker for the air conditioner e Potential risk of electric shock or fire Do not insert anything such as fingers or branches into the air conditioner vents while the air conditioner is running e Keep the children away from the air conditioner to prevent them from putting their finger on the air conditioner Potential risk of personal injury If any foreign substance
11. UAY 000 405 437 33 www samsung com 1800 3000 8282 PARAGUAY 009 800 542 0001 www samsung com py INDIA www samsung com in ie ng 0800 124 421 Demais cidades e regides 1800 266 8282 BRAZIL Mp www samsung com br LUXEMBURG 261 03 710 www samsung com 4004 0000 Capitais e grandes centros MONTENEGRO 020 405 888 www samsung com ciie 800 SAMSUNG 726 7864 inasa NETHERLANDS 0900 SAMSUNG 0900 7267864 0 10 Min www samsung com HHP 02 24828200 NORWAY 815 56480 www samsung com BOLIVIA 800 10 7260 www samsung com 0 801 172 678 lub 48 22 607 93 33 COLOMBIA pro 112112 www samsung com co HHP 0 801 672 678 lub 48 22 607 93 33 Bogot 0001272 POLAND catkowity koszt potaczenia jak za 1 impuls www samsung com pl COSTARICA 0 800 507 7267 wawsamsung comlatin Spanish wed ug taryfy operatora www samsung com latin_en English koszt potaczenia wedtug taryfy operatora DOMINICA 1 800 751 2676 wwwsamsung com latin Spanish A ti i PORTUGAL 808 20 SAMSUNG 808 20 7267 www samsung com Awi sansung coma en Engish ROMANIA 08008 SAMSUNG 08008 726 7864 y ECUADOR 1 800 10 7267 wawsamsung com atin Spanish www samsung com ro i i TOLL FREE No g www samsung com latin_en English l tin Spani SERBIA 011 321 6899 www samsung com rs EL SALVADOR 800 6225 www samsung com latin Spanish www samsung com latin_en English SLOVAKIA 0800 SAMSUNG 0800 726 786 www samsung com www samsung com latin Spanish SPAIN 902 1 SAMSUNG 902 172
12. ade pin lever Air flow blade Display r Operation indicator Timer indicator L i x E oa Turbo indicator _poro Y Your air conditioner may slightly look different from illustration shown above depending on your model 10_ viewing REMOVING THE FRONT PANEL Tightly grab both side of the front panel and lift up the panel to open Then slide the panel towards to remove the panel Power button and Room temperature sensor You may locate the Power l button on the right bottom side of the air conditioner If the front panel is open you can check the room temperature sensor You can turn on the air conditioner without the remote control by pressing the Power button The room temperature sensor measures indoor room temperature Room temperature sensor viewing 11 HSITONA Viewing your air conditioner CHECKING THE REMOTE CONTROL You can activate the air conditioner by pointing the remote control away from it When using the remote control always point it directly at the air conditioner Remote control display Mode Set one of the 5 operating modes See pages14 18 for instructions Turbo Operate in maximum fan speed to cool warm quickly Air swing FYI Activate Deactivate air flow blade movement automatically up and down good sleep Set the good sleep mode on off
13. cally Oi good sleep Press the On Timer button on the remote control to change the time setting while On timer indicator is blinking You can set the time up to 24 hours increasing in 30 minute unit up to first 3 hours and in hourly unit after first 3 hours 000006 i 4 d Cl 3 Press the Power l amp Set Cancel button on the remote control to active it on The remote control display will show the hour s you have set The air conditioner will operate automatically at set time and then On timer indicator disappears If On timer is not set within 10 seconds the air conditioner will end setting 4 Set the operating mode Press the Mode button on the remote control until the desired mode appears on the remote control display The air conditioner will operate in the mode you set eq Y On timer function is available in Auto Cool Dry Fan Heat mode Y e Temperature can also be adjusted See step 3 on page 15 for instructions e After the set up while the unit is off approximately after 10 seconds all the other indicators will be gone except the On timer indicator and remaining time e Setting time allows you to change by pressing the On Timer button Press the On Timer button to change time setting and then press the Power amp Set Cancel button to active it on To deactivate the On timer 1 Press the Power amp Set Cance
14. d Mobile www samsung com ph MONGOLIA 7 800 555 55 55 www samsung com 02 4222111 Other landline BELARUS 810 800 500 55 500 www samsung com SINGAPORE 1800 SAMSUNG 726 7864 www samsung com sg EEE Y netmeligine Uygundur This EEE is compliant with RoHS Wall Mounted Type Series Neo Forte MH xFN 100 Recycled Paper imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung com register ENE FRM RODE DB98 28925A 8
15. e power cable Do not bend the power cable excessively e Potential risk of fire or electric shock To protect the product from water and possible shock you should keep the power cable and the connection cord of the indoor and outdoor units in the protection tube When opening or closing the front panel use a stable stool and watch your steps carefully Disconnect the air conditioner from power supply before it is repaired or disassembled Clean the air conditioner after the inner fan stops operating e Potential risk of injury or electric shock safety information _05 HSITON3 Safety Information 44SEVERE WARNING SIGNS CONT D Use a receptacle that has a ground terminal The receptacle must be used exclusively for the air conditioner e Improper electrical grounding may cause electric shock or fire Be sure to ground the unit Do not connect the ground wire fo gas or water pipes lighting rods or telephone grounding ines e f the unit is not properly grounded electric shock may result If the appliance generates a strange noise a Suring smell or smoke cut off the power supply immediately and contact the nearest service center e Potential risk of fire or electric shock N Do not block or place items in front of the air conditioner Do not step hang onto or place heavy items on the air conditioner e Potential risk of personal injury If failure or camage occurs on the conditions of impr
16. e current room temperature The unit operates for 30 minutes and then operates in last used mode or in Auto mode if Dry Fan mode is most recent mode used Turbo function is only available in Auto Cool Heat mode If Turbo function is selected in Dry Fan mode operating mode changes to Auto To deactivate Turbo function 1 Press the Turbo button on the remote control again The air conditioner operates in last used mode or in Auto mode if Dry Fan mode is most recent mode used Y e When you are using the remote control make sure corresponding indicator appears on the remote control display e Temperature Fan speed cannot be adjusted while using this function e Air flow can be adjusted manually See page 19 for instructions e When the Turbo function is activated pressing Mode button will automatically cancel the function 20_ using advanced functions SETTING TIMER This advanced Timer function allows you to turn on off your air conditioner automatically even when you are away Simply set the time and your air conditioner will turn on off automatically On timer This function allows you to turn on the air conditioner automatically within the time range of 24 hours On timer is available while your air conditioner is on off 1 Press the On Timer button on the remote control On timer indicator blinks on the remote control display HSITONA 2 Set the time you want the air conditioner to turn on automati
17. e air conditioner automatically adjusts the fan speed to Auto in Auto Dry mode Timer function does not set e Check if you press the Power d Set Cancel button on the remote control after you have set the time Odors permeate in the room during e Check if the appliance is running in a smoky area or if there is a smell entering from outside Operate the air operation conditioner in Fan mode or open the windows to air out the room The air e A bubbling sound may be heard when the refrigerant conditioner is circulating through the compressor Let the air makes a bubbling sound conditioner operate in a selected mode appendix _31 appenalx Water is dripping from the air flow blades e Check if the air conditioner has been cooling for an extended period of time with the air flow blades pointed downwards Condensation may generate due to the difference in temperature Remote control is not working e Check if your batteries are depleted e Make sure batteries are correctly installed e Make sure nothing is blocking your remote control sensor e Check that there are strong lighting apparatus near the air conditioner Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves OPERATION RANGES The table below indicates the temperature and humidity ranges the air conditioner can be operated within Refer to the table for efficient use
18. e air conditioner is properly on The air conditioner will operate in the most recent operation mode used or Auto mode When you turn off the air conditioner air flow blade will stop moving and remain closed T NT good sleep 006CEDE Turning on off your air conditioner without the remote control You can operate your air conditioner by pressing the Power button on the right bottom side of the air conditioner SELECTING OPERATION MODE Auto In Auto mode the air conditioner will automatically set the temperature and fan speed depending on the room temperature detected by the room temperature sensor 1 Turn on the air conditioner Press the Power amp Set Cancel button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Auto mode and Auto fan speed indicator appear on the remote control display The air conditioner will automatically set the operation mode to Cool or Heat depends on the room temperature H a gt D o Y When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the Temperature Press the Temperature A or Y button on the remote control to increase or decrease the desired temperature You can set the desired temperature between the range of 16 C 30 C You can increase decrease the temperature by 1 C Y e When the air condit
19. electric shock or fire e f installing in specialty areas such as a factory complex or saline coastal area consult the place of purchase or contact center for specific installation details l e The units must be installed according to distances declared in order to permit l l accessibility from each side either to guarantee correct operation of maintenance or ropan roducts The unit s parts must be reachable and removable completely under safety condition for people or things Consult a dealer regarding the appropriate measures to prevent the allowable concentration trom being exceeded e f the merani leaks and cause the concentration limit to be 6X00 ed hazards due to lack of oxygen in the room may result If the indoor unit gets wet turn the power off immediately and call your nearest contact center e Potential risk of fire or electric shock Always make sure that the power supply is compliant with current safety standards Always install the air conditioner in compliance with current local safety standards Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines Use a rated circuit breaker only e Never use steel wires or copper wires as a circuit breaker It may cause fire or unit malfunctions Do not put undue stress or place heavy object on th
20. emote control make sure correct indicator which matches your selection appears on the remote control display e Air flow can be adjusted manually See page 19 for instructions 16 operating Fan Fan mode can be selected to ventilate your room Fan mode will be helpful to refresh the stale air in your room 1 Turn on the air conditioner Press the Power l amp Set Cancel button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Fan mode indicator appears on the remote control display The air conditioner operates in Fan mode and automatically adjusts the temperature according to the current room temperature HSITONA Y When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the fan speed Press the Fan Speed y button on the remote control to set the desired fan speed ee Y When you press the Fan Speed button fan speed will change in order of Auto Low Medium and High Y e When you are using the remote control make sure correct indicator which matches your selection appears on the remote control display e Air flow can be adjusted manually See page 19 for instructions operating _17 operating basic tunction SELECTING OPERATION MODE Heat The air conditioner heats as well as cools Warm your room with this versatile appliance in the cold of winter 1 Turn on the air conditio
21. filter is cleaned with a vacuum or by hand washing 1 Remove the front panel Tightly grab both side of the front panel and lift up the panel to open Then slide the panel towards you to remove the panel 2 Grab the handle and lift it up Then pull the Air filter towards you 3 Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy then rinse it with running water and dry it in a ventilated area Y e For the best conditions repeat every two weeks e If the Air filter dries in a confined or humid area odors may generate If it occurs re clean and dry it in a well ventilated area 4 Insert the Air filter back in its original position 5 Close the front panel 26_ cleaning and maintaining Bio filter Washable foam based Bio filter leads to reduction in allergens that thrive in polluted air The filter is cleaned with a vacuum or by hand washing 1 Remove the front panel Tightly grab both side of the front panel and lift up the panel to open Then slide the panel towards you to remove the panel HSITONA MI mm ANN ANNA e Bio filter can be placed in any 4 slots beneath the air filter e Front panel of your air conditioner is actually not detachable 3 Clean the Bio filter with a vacuum cleaner or soft brush The
22. ice cycle is completed 30_ cleaning and maintaining appenalx TROUBLESHOOTING Refer to the following chart if the air conditioner operates abnormally This may save time and unnecessary expenses PROBLEM SOLUTION The air conditioner does not operate HSITON3 e Because of the protective mechanism the appliance does not start operating immediately to keep the unit from overloading immediately The air conditioner will start in 3 minutes after it has been restarted The air e Check power status and then operate the air conditioner does not work at all conditioner again e Check if the circuit breaker is switched off e Check if there is a power failure e Check your fuse Make sure it is not blown out The temperature does not change e Check if you selected Fan mode Press the Mode button on the remote control to select another mode The cool warm air does not come out of the air conditioner e Check if the set temperature is higher lower than the current temperature Press the Temperature A or V button on the remote control to change the set temperature Press the Temperature A or V button to increase or decrease the temperature e Check if the air filter is blocked by dirt Clean the Air filter every two weeks e Check if the air conditioner has just been turned on If so wait 3 minutes The fan speed does not change e Check if you selected Auto or Dry mode Th
23. icing cleaning and installing the air conditioner SAFETY INFORMATION Before using your new air conditioner please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance HSITON3 Because the following operating instructions cover various models the characteristics of your air conditioner may differ slightly from those described in this manual If you have any questions call your nearest contact center or find help and information online at www samsung com Important safety symbols and precautions Hazards or unsafe practices that may result in severe WARNING personal injury or death A Hazards or unsafe practices that may result in minor CAUTION personal injury or property damage To reduce the risk of fire explosion electric shock or CAUTION personal injury when using your air conditioner follow these basic safety precautions Do NOT attempt Do NOT disassemble Do NOT touch Follow directions carefully Cut off the power supply Make sure the machine is grounded to prevent electric DISETZ shock Call the contact center for help E Note These warning signs are here to prevent injury to you and others Please follow them carefully After reading this section keep it in a safe place for future reference safety information _03 safety information ASEVE
24. ioner is already operating in another mode press the Mode button until Auto mode indicator appears on the remote control display e When you are using the remote control make sure correct indicator which matches your selection appears on the remote control display e Air flow can be adjusted manually See page 19 for instructions 14_ operating Cool In Cool mode the air conditioner will cool your room You can adjust the temperature and the fan speed to feel cooler in hot season 1 Turn on the air conditioner Press the Power amp Set Cancel button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Cool mode indicator appears on the remote control display SET TEMP E o The air conditioner operates in Cool mode and it will Ll lower the temperature in your room HSITONA 8 When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the temperature Press the Temperature A or V button on the remote control to increase or decrease the desired temperature You can set the desired temperature between the range of 16 C 30 C Y You can increase decrease the temperature by 1 C 4 Set the fan speed Press the Fan Speed sh button on the remote control to set the desired fan speed If room temperature reaches desired value the air conditioner will shut off cooling for a while and just the fan runs
25. l button on the remote control On timer you set will be canceled and On timer indicator will disappear using advanced functions _21 Using advanced functions SETTING TIMER Off timer This function allows you to turn off the air conditioner automatically within the time range of 24 hours Off timer is functional when the unit is operating 1 Press the Off Timer button on the remote control Off timer indicator blinks on the remote control display Sy D o E AY 2 Set the time you want the air conditioner to turn off automatically Press the Off Timer button on the remote control to change the time setting while Off timer indicator is blinking You can set the time up to 24 hours increasing in 30 minute unit up to first 3 hours and in hourly unit after first 3 hours E a Can mn JA AO good sleep 3 Press the Power amp Set Cancel button on the remote control to active it on The remote control display will show the hour s you have set The air conditioner will turn off automatically at set time and then Off timer indicator disappears If Off timer is not set within 10 seconds the air conditioner will end setting Y e Setting time allows you to change by pressing the Off Timer button Press the Off Timer button to change the time setting and then press the Power l amp Set Cancel button to active it on e You can combine Off timer f
26. ment This marking on the product accessories or literature indicates that the product and its electronic accessories e g charger headset USB cable should not be disposed of with other household waste at the end of their working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take these items for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product and its electronic accessories should not be mixed with other commercial wastes for disposal contents _09 Viewing your alr conditioner Congratulations on the purchase of the air conditioner We hope you enjoy the features of your air conditioner and stay cool or warm with optimal efficiency Please read the user manual to get started and to make the best use of the air conditioner CHECKING THE INDOOR UNIT AND DISPLAY Carefully unpack your air conditioner and check the unit to make sure it is not damaged Main parts Air filter under the panel a C Air intake Lt 1EM A Air flow blade a a AER Power button Bl
27. mmended 18_ operating ADJUSTING THE AIR FLOW DIRECTION Air flow can be directed to your desired position Vertical air flow Air flow blades move up and down 1 Press the Air swing button on the remote control Air swing indicator will be on and air flow blades move up and down continuously to circulate the air HSITONA To keep the air flow direction in a constant position press the Air swing button on the remote control again SET TEMP Re M Horizontal air flow Make sure one of the blade pins that stick out of the air flow blades are not broken 1 Move the blade pin lever left or right to keep the air flow direction in a constant position you N Be extremely careful with your fingers while adjusting the oe Horizontal air flow direction There is a potential risk of personal injury when the unit is mishandled operating _19 Using advanced functions USING THE TURBO FUNCTION Turbo function will be helpful to cool or heat your room quickly and effectively by operating at the maximum fan speed for 30 minutes 1 Turn on the air conditioner Press the Power amp Set Cancel button on the remote control 2 Set the operating mode Press the Turbo button on the remote control until Turbo indicator appears on the remote control display The air conditioner operates in Turbo fan speed and automatically adjusts the temperature according to th
28. n rinse it with running water and dry it in a ventilated area 4 Install the Bio filter back in position 5 Close the front panel Y Clean the Bio filter every 3 months The cleaning term may differ on usage and environmental conditions cleaning and maintaining _27 Cleaning and maintaining the alr conditioner REPLACING THE FILTER Replacement filter may be purchased from the retail store or ordered from the dealer where you purchased the unit If you cannot find one please call a contact center Deodorizing filter Deodorizing filter absorbs efficiently cigarette smoke pet odors and other unpleasant smells Deodorizing filter cleaning is simple just remove old filter and install a new one 1 Remove the front panel Tightly grab both side of the front panel and lift up the panel to open Then slide the panel towards you to remove the panel 2 Slide the Deodorizing filter color in black out to remove it from the slot e Deodorizing filter can be placed in any 4 slots beneath the air filter e Front panel of your air conditioner is actually not detachable 3 Install the new Deodorizing filter back in position 4 Close the front panel Y e The replacement timing of the Deodorizing filter differs depending on usage and environmental conditions e Even if Deodorizing and Bio filters are
29. ner Press the Power amp Set Cancel button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Heat mode indicator appears on the remote control gt o display The air conditioner operates in Heat mode and warms paa your room r Y When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the temperature Press the Temperature A or V button on the remote control to increase or decrease the desired temperature You Can set the desired temperature between the range of 16 C 30 C You can increase decrease the temperature by 1 C 4 Set the fan speed Press the Fan Speed sy button on the remote control to set the desired fan speed E If room temperature reaches desired value heating will stop for a while 64 e When you press the Fan Speed button fan speed will change in order of Auto Low Medium and High e Fan may not operate for about 3 5 minutes at the beginning to prevent any cold blasts while the air conditioner is warming up L e Air flow can be adjusted manually See page 19 for instructions e Since the air conditioner heats the room by taking heat energy from outdoor air the heating capacity may decrease when outdoor temperatures are extremely low If you feel the air conditioner insufficiently heats using an additional heating appliance in combination with the air conditioner is reco
30. ng apparatus using the ballast elf you use the wireless remote control reception error may occur due to the ballast of the lighting apparatus Install the outdoor unit where operating noise and vibration will not disturb your neighbor and in a well ventilated area with no obstacle e Potential risk of malfunction l e Operating noise may disturb your neighbor Make sure that there are no obstacles or covers that block the air conditioner Allow sufficient space for air circulation e Insufficient ventilation may result in poor performance If the power cable is damaged the manufacturer or a qualified service technician must replace it If a power outage occurs while the air conditioner is working turn off the power source immediately Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency Check for damage on delivery If damaged do not install the air conditioner and call the place of purchase immediately Keep indoor temperatures stable and not extremely cold especially where there are children elderly or disabled people The packaging material and used batteries of the remote controller optional must be disposed of in accordance with the national standards The refrigerant used in the air conditioner must be treated as chemical waste Dispose the refrigerant following national standards Have a qualified service technician install
31. o ENGLISH features of your new alt e onaltoner Cool Summer Offer On those hot sweltering summer days and long restless nights there is no better escape from the heat than the cool comforts of home Your new air conditioner brings an end to exhausting hot summer days and lets you rest This summer beat the heat with your own air conditioner Cost Efficient System Your new air conditioner not only provides maximum cooling power in the summer but can also be an efficient heating method in the winter with the advanced Heat pump system This technology is up to 300 more efficient than electrical heating so you can further reduce its running cost Now meet year round needs with one air conditioner A Look for Everywhere The elegant and harmonious design gives priority to the esthetics of your space and complements any of your existing interior d cor With its soft color and rounded edge shape the new air conditioner adds class to any room Enjoy what your air conditioner offers both functionally and esthetically good sleep function good sleep mode allows you to set a comfortable sleep temperature while saving energy and having sound sleep EBI Fo down You will find your model number on the right side of the air conditioner 02_ features r easy future reference write the model and serial number Model Serial Safety information To prevent electric shock disconnect the power before serv
32. oper use not followed by the installation manual there will be an extra labor charge for installing and construction e Potential risk of malfunction electric shock or fire if repairs or installations are attempted by a non qualified service technician Do not spray flammable gases such as insecticide near the air conditioner e Potential risk of electric shock fire or unit malfunction Do not open the front grille during operation e Potential risk of electric shock or unit malfunction Cool Air should not flow directly towards people pets and ants Pi is harmful to your health pets and plants Do not drink drain water coming out of the air conditioner e Potential risk of health hazard Do not allow children to climb on the air conditioner Do not use the air conditioner as a cooling precision instrument for food pets plants cosmetics or machinery Do not pull or give excessive shock to the air conditioner e Potential risk of fire or unit malfunction and there are risk of personal injury because unit may fall down Do not spray water directly on the air conditioner or use benzene thinner or alcohol to clean the surface of the unit e Potential risk of electric shock or fire e Potential risk of damage to the air conditioner Do not place any objects especially containers with liquid 06_ safety information Do not touch the pipe connected to the air conditioner Install the indoor unit away from lighti
33. ours Press good sleep button on the remote control to change the time setting while Off timer indicator is blinking f You can set the time up to 12 hours increasing in l 30 minute unit up to first 3 hours and in hourly unit after first 3 hours 4 Press the Power amp Set Cancel button on the remote control to active it on The remote control display will show the hour s you have set When the set time has elapsed the air conditioner will automatically turn off and then good sleep indicator disappears If good sleep mode is not set within 10 seconds the air conditioner will end setting Y e Temperature Fan speed Air swing can be adjusted after setting good sleep in Heat mode e Temperature can be adjusted and the air conditioner automatically adjusts the Fan speed Air swing after setting good sleep in Cool mode 24_ using advanced functions Temperature changes in good sleep mode To prevent excessive cooling heating during sleep the good sleep mode automatically modifies the temperature setting in accordance with the time setting Temperature and air current change according to the three stages Fall asleep Sound sleep and Wake up from good sleep mode and then the air conditioner will automatically turn off when the set time has elapsed Three stage good sleep prevents you from having difficulty sleeping in summer winter night O Fall asleep Eases you into sleep by dropping the tem
34. perature Sound sleep Relaxes your body and raises your temperature slightly Wake up from good sleep mode Allows you to wake up from comfortable intermittent air and it makes you feel refresh Y e Set Off timer in good sleep mode over 5 hours You feel disturbed sleep if the good sleep is set too short or long because the default is set to 8 hour operation e f the good sleep mode is set less than 4 hours the operation will stop at the set time If the good sleep mode is set over 5 hours it will run as Wake up stage for the last one hour before stop e Recommended set temperature is between 25 C 27 C for cooling and 21 C 23 C for heating To deactivate good sleep mode 1 Press the Power amp Set Cancel button on the remote control good sleep mode you set will be canceled and good sleep indicator will disappear using advanced functions _25 HSITONA Cleaning and maintaining the alr conditioner CLEANING THE EXTERIOR 1 Wipe the surface of the unit with a slightly wet or dry cloth when needed A Do not use Benzene Thinner or 2 Clorox They may damage the surface of the air conditioner and can create a risk of fire CLEANING THE FILTER When cleaning the filter make sure to to turn off the power of the indoor unit No special tools are needed to clean it Air filter Washable foam based air filter captures large particles from the air The
35. r The air conditioner will turn off and then on automatically Set up should be done while the air conditioner is operating For example If the On timer is set at 3 hours and el TAE the Off timer at 1 hour the air conditioner will turn off Du OS l automatically an hour after the set time and remain off y for 2 hours before turning on automatically See page 22 for more detail instructions on setting Off timer To deactivate the timer combination 1 Press the Power amp Set Cancel button on the remote control Both of the On and Off timer will be canceled and the indicators will disappear using advanced functions _23 HSITONA Using advanced functions SETTING TIMER good sleep mode good sleep mode allows you to set a comfortable sleep temperature while saving energy and having sound sleep good sleep mode can be set up when the air conditioner is on 1 Set the operating mode Press the Mode button on the remote control until Cool Heat appears on the remote control display good sleep is only available in Cool Heat mode 2 Press the good sleep button on the remote control good sleep indicator appears and Off timer indicator starts blinking on the remote control display O 3 Set the length of time you want the air conditioner to omg tay on N Slay 9 Off Timer Default good sleep time is set to 8 h
36. s described are essential to guarantee the efficiency of the air conditioner The frequency of these operations varies according to the characteristics of the area the amount of dust etc 1 The described operations should be performed more frequently if the area of installation is very dusty 2 These operations must always be performed by qualified personnel For more detailed information see the Installation Manual cleaning and maintaining 29 Cleaning and maintaining the alr conaltioner MAINTAINING YOUR AIR CONDITIONER Internal protections via the unit control system This internal protection operates if an internal fault occurs in the air conditioner Type Description i i i i the heat i Aarin call ai The internal fan will be off to against cold air when the heat pump is heating De i The internal fan will be off to against cold air when the heat pump is ia E heating Anti protection of The compressor will be off to protect internal battery when the air internal battery conditioner operates in Cool mode The air conditioner does not start operating immediately to protect the Protect compressor compressor of the outdoor unit after it has been started If the heat pump is operating in Heat mode De ice cycle is actuated to remove frost from an outdoor unit that may have deposited at low temperatures The internal fan is switched off automatically and restarted only after the de
37. such as water has entered the appliance cut off the power supply and contact the nearest service center e Failing to do so may result in electric shock or fire Turn off the air conditioner using the provided remote control or control accessory 4 provi ar Do not cut off the power supply to turn off the unit unless there is an immediate danger Do not run the air conditioner for an extended period of time in a room with the door closed or with babies elderly or disabled people e Open the door or windows to ventilate your room at least once an hour to prevent oxygen shortage The air conditioner is composed of moving parts Keep children away from the unit to avoid physical injury Make sure that children take precautions against access to the air conditioner and they do not play with the unit Do not clean the interior of air conditioner on your own e You may damage the parts which can cause electric shock or fire 04_ safety information e Consult contact center for cleaning the interior of the air conditioner Do not connect the air conditioner with heating apparatus or attempt to disassemble remodel or repair it yourself e Potential risk of malfunction electric shock or fire If repairs are needed consult the contact center Consult the place of purchase or contact center to install reinstall or disassemble the air conditioner e Improper installation carries a risk of unit malfunction water leakage
38. the air conditioner and perform a trial operation Firmly connect the drain hose to the air conditioner for proper water drainage Check for damages on the outdoor unit installation pad at least once a year l e Potential risk of personal injury or property loss When using a wireless remote control the distance should not be more than 7 meters from the air conditioner If the remote control is not used for a long period of time remove the batteries to prevent leakage of electrolyte When cleaning the outdoor unit touch the heat exchanger radiator fins with extreme care e Wearing thick gloves can protect your hands Make sure that the condensed water dripping from the drain hose runs out properly and safely HSITON3 safety information 07 safety Information The appliance is not intended for use by persons gneluding ees with reduced physical sensory or menta capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Young children should be supervised to ensure that they do not play with the appliance CAUTION Inspect the condition electric connections pipes and external case of the air conditioner regularly by a qualified service technician Do not open doors and windows in the room being cooled during operation unless necessary Do not block the air conditioner vents If objects block the
39. unction with On timer function to turn on and then off the air conditioner at the desired time See page 23 for instructions To deactivate the Off timer 1 Press the Power amp Set Cancel button on the remote control Off timer you set will be canceled and Off timer indicator will disappear 22 using advanced functions Combining On timer and Off timer You can combine the On timer and Off timer together for more convenient use of the timer function 1 Set the On timer Press the On Timer button alar Gum Set the time with On Timer button Press Power amp Set Cancel button to activate the a On timer j F l good sleep CJ AGE See page 21 for more detail instructions on setting On timer 2 Set the Off timer Press the Off Timer button Set the time with Off Timer button Press Power amp Set Cancel button to activate the Off timer When you set the time there can be two possible options On timer is shorter than Off timer The air conditioner will turn on and then off automatically Set up should be done while the air conditioner is off For example If the On timer is set at 3 hours and the Off timer at 5 hours the air conditioner will turn off automatically 3 hours after the set time and then operate for next 2 hours before turning off automatically E lait CI TITO a ON TIMER h Cue pi OFF TIMERJ HD On timer is longer than Off time