Home

IADS-PROG IADS Connection Hub User Guide

image

Contents

1. Manufacturer UTC Fire amp Security Americas Corporation Inc 1275 Red Fox Rd Arden Hills MN 55112 6943 USA Authorized EU manufacturing representative UTC Fire amp Security B V Kelvinstraat 7 6003 DH Weert Netherlands Certification C European Union directives 1999 5 EC R amp TTE directive Hereby UTC Fire amp Security declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC 6 IADS PROG IADS Connection Hub User Guide 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info Contact information www utcfireandsecurity com or www interlogix com Customer support www interlogix com customer support IADS PROG IADS Connection Hub User Guide IADS PROG IADS Connection Hub User Guide
2. be ignored Remember that each device within each IADS network must have a unique address Double addressing within the same line is forbidden and can cause unpredictable problems or behaviour IADS PROG IADS Connection Hub User Guide Press Read Device button to read and display the device values in fields Device Name Actual Device Category and Type Press Reset button to reset the application If no device is connected Device Name will show no device and other fields will be blank or 0 If an IADS device is already connected its settings will be displayed accordingly Press Close button to close the AdDev application Attributes The attributes Open Close Device Failure and LED Toggle are also shown in the AdDev application If magnetic contact MK46 AD is attached to the IADS connection hub the attribute Open Close shows a black box if the contact is closed or green box if the contact is open The Device Failure box is normally black it turns to red colour if the magnetic contact has an electric failure for example if the device draws current higher than 10 mA or has a short circuit Specifications Supply voltage 5 V 5 USB powered Current consumption Programming mode 90 mA max Converter mode 31mA Max devices connected to IADS output 1 Maximum Baudrate in converter mode 250 kbit s Dimensions W x H x D 100 x 60 x 25 mm Regulatory information
3. the IADS connection hub so that the yellow LED is on The IADS connection hub is now in the converter mode After that it is possible to connect the Titan software to the ATS control panel to manage and configure the panel For further information on programming see appropriate panel programming and management manuals as well as Titan online help system IADS device programming mode When using the IADS connection hub in programming mode use the AdDev software from the supplied CD You can copy the software to the computer hard disk or run it directly from the CD Note To copy the software copy the application file AdDev102 exe and the configuration file AdDev ini into the same directory No administration privileges are required to copy or run the application Figure 3 IADS device programming mode IADS connetion hub two core cable Point ID contact Connect the IADS connection hub as shown in Figure 3 above The IADS connection hub should be connected via the USB cable to the computer Connect a programmable device via two wire cable to the IADS connection hub and press Mode button to set the addressing mode until the green LED is on Double click the application file AdDev102 exe to run the software 4 IADS PROG IADS Connection Hub User Guide Figure 4 AdDev software interface GD AdDev Rev 1 1 E Ioj x Device Name m Settings COM Port Scan Ports Language English Current
4. Address Change Address To d p l 74 n U D Attributes _ Category Type _ Open Close D 0 u Device Failure _ State Read Device Reset Close If necessary choose the appropriate language from the Language combo box In the AdDev application choose a correct COM port or search through the COM port list to find the IADS connection hub by pressing Scan Ports During the start up the application will scan all ports and search for the IADS connection hub if connected already State will show a status of the communication with the computer via USB The following values are possible e Operation successful e Operation failed e No connection If a device found which is recognized by the application the device name will be displayed in the field Device Name as well as the corresponding attributes and the current address The state will be Operation successful If no device or an unknown device is connected the field Device Name will show No device or No IADS device All other fields will stay blank or 0 Use buttons Read Device Write Device and LED toggle to tested or address the connected IADS device To change the address of a device enter a new address or select it from combo box Use button Write Device to write a new address The new address will be then shown in the Current Address field The allowed address range is from 0 to 31 Other values will
5. LED indicates the USB to serial converter mode the green LED means IADS device programming mode e The USB plug is used for hooking up the IADS connection hub to the computer via the USB cable which is a part of the package Each time the IADS connection hub has been connected to the USB port of the computer it powers up and performs an internal self test If the internal self test has been successfully performed it automatically switches into IADS device programming mode and the green LED switches on In case when a problem occurs during the internal self test the green and the yellow LEDs blink alternately In this case return the IADS connection hub to UTC Fire amp Security for verification and maintenance purpose Avoid detaching the IADS connection hub either from a control panel a programmable device or from a PC when the actual programming or data exchange function is in progress it can affect correct and successful operation USB to serial converter mode This mode allows to connect ATS control panels that currently have a 9 pin RS232 connector transparently to a computer usually a notebook which are mostly equipped only with USB ports The IADS connection hub should be connected via the USB cable to the notebook and via a 9 pin RS232 cable to an ATS control panel Figure 2 USB to serial converter mode IADS connetion hub ATS panel IADS PROG IADS Connection Hub User Guide 3 Press Mode button on
6. de UTC Fire amp Security A United Technologies Company Document MS02210211 R1 0 IADS PROG IADS Connection Hub User Guide EN Part number MS02210211 Ca LI interlogix AUTO Fire amp Security Compary IADS PROG IADS Connection Hub User Guide Content Description 1 Packaging 2 Prerequisites 2 Setup and connections 2 USB to serial converter mode 3 IADS device programming mode 4 Attributes 6 Specifications 6 Regulatory information 6 Contact information 7 Copyright 2011 UTC Fire amp Security All rights reserved Description The IADS PROG IADS connection hub is designed for the following functions It allows to connect computers notebooks desktop PCs etc to ATS control panels creating a bridge between a USB port of the computer and an RS232 connection of the control panel See USB to serial converter mode on page 3 for more details It also allows address programming for addressable detectors or other components for example magnetic contact type MK 46 AD which do not provide a physical way of address change The programming mode allows connecting a detector or component via two wire cable to a USB port of a computer which runs an application to monitor the device and to change the corresponding address in an IADS network See IADS device programming mode on page 4 for more details PIN MS022 10211 REV 1 0 ISS 23MAR11 Print Instructions A5 8 pages manual Boo
7. klet Stapled e ee a Mikhail Sleptsov 2011 03 23 FF Property UTC Fire amp Security 5 E interlogix A UTC Fire amp Security Company IADS PROG IADS Connection Hub User Guide Content Description 1 Packaging 2 Prerequisites 2 Setup and connections 2 USB to serial converter mode 3 IADS device programming mode 4 Attributes 6 Specifications 6 Regulatory information 6 Contact information 7 Copyright 2011 UTC Fire amp Security All rights reserved Description The IADS PROG IADS connection hub is designed for the following functions e It allows to connect computers notebooks desktop PCs etc to ATS control panels creating a bridge between a USB port ofthe computer and an RS232 connection of the control panel See USB to serial converter mode on page 3 for more details e It also allows address programming for addressable detectors or other components for example magnetic contact type MK 46 AD which do not provide a physical way of address change The programming mode allows connecting a detector or component via two wire cable to a USB port of a computer which runs an application to monitor the device and to change the corresponding address in an IADS network See IADS device programming mode on page 4 for more details P N MS02210211 REV 1 0 ISS 23MAR11 Packaging The packaging includes the following components e 1x User Guide this document e 1x USB A to USB B connection cab
8. le e 1x IADS connection hub e CD with the AdDev management application Prerequisites The physical connections are described in the corresponding chapter The requirements for running the software are e A free USB port e One of the following operating systems Windows XP Windows Vista Windows 7 There are no administrator requirements It might be necessary to configure the system or any firewalls security software to allow access to the USB port Please be aware that the first version of Titan supporting programmable devices programmed with the IADS connection hub is ATS800301 05 12 however this Titan version supports only certain programmable devices Setup and connections The IADS connection hub is shown in Figure 1 below Figure 1 IADS connection hub layout Yellow LED USB to serial converter USB connector Mode button RS232 connector Green LED Programming mode IADS 2 way connector 2 IADS PROG IADS Connection Hub User Guide e The RS232 plug can be connected with an RS232 cable male male 9 pin connectors to the ATS control panel e The IADS 2 way connector can be used for hooking up a sensor component for addressing Only one sensor component is allowed to be connected at any time brown cable on black cable on e Mode button allows toggling between RS232 connection and IADS 2 way connector output e LEDs show which output a computer is connected to The yellow