1. have used a port other than port 80 you must add port number at the end For example if the port used is 81 the IP address entered should look like this http 192 168 1 250 81 or Use the Paradox IP Exploring Tools software click Refresh and double click on your IP100 in the list 2 Enter your alarm system s User Code and IP100 password default paradox Off Site Access 1 Go to www paradoxmyhome com siteID replace siteID by the siteID you used to register with the ParadoxMyHome service 2 Enter your alarm system s User Code and IP100 password default paradox Firmware and Language Update To update an IP100 using IP Exploring 1 Open IP Exploring Tools 2 Click the Language Update tab see Figure 9 3 Select your preferred language in the Language drop down list 4 Select the correct Connection Mode from the following three types Locally Select your IP100 from the Site Name list Remotely Enter your module s IP Address as shown in the Exploring Mode tab and NEware Port default 10000 Click the Exploring Mode tab right click the IP100 and select More Details ParadoxMyHome Enter your IP module site ID 5 Enter the module password 6 Click Update Module A Web update progress box appears see Figure 10 If a new firmware version is found you are informed of the old version number and you will have to confirm the installation of the new version The update process begi
2. access the system from anywhere in the world Step 1 Setting up the Router This step allows you to set up the router so that the IP100 module can function properly 1 Ensure that the router is connected properly as indicated in the router s instructions 2 Access your router s configuration page Refer to your router s manual for the exact procedure In most cases this is done by entering the router s static IP address in the address bar of your Web browser see Figure 3 For this manual we will use 192 168 1 1 as an example since it is a commonly used default router IP address Your router s IP address may be indicated in the router s instructions or on a sticker on the router 3 In the router s configuration page check the DHCP settings If DHCP is enabled verify that the IP address range leaves at least one IP address available outside of the range The range shown in Figure 4 would leave addresses 2 to 4 and 101 to 254 available all the numbers in an IP address are between 1 and 254 Record one of the addresses outside the DHCP range as the one you will use for the IP100 If DHCP is disabled the IP100 will use the default address of 192 168 1 250 It is possible to change that address if needed using the Paradox IP Exploring Tools software 4 In the router s configuration page go to the Port Range Forwarding section also known as port mapping or port redirection Add a service it
3. IP100 EI08 Email Notification Home PC Router Router Web Access IPR512 IP Receiver Monitoring Station Control Panel IP100 WAN A LED ERROR On until both the control panel and network are detected On when DHCP server is not responding On during a reset Flashes during firmware upgrade RX Flashes when receiving data from the panel TX Flashes when sending data to the panel POLLING On when connected with paradoxmyhome com STATUS On when a user is connected LINK On when connected to a network LAN Flashes when transferring data through the LAN B To reset the module to its default settings press and hold the RESET button for 5 seconds release it and then press it again while the Error LED is flashing The Error LED will remain lit during the reset C Connect to the router CAT 5 Ethernet cable D Connect to the SERIAL connector of the panel 4 pin serial cable E Connect to a 307USB and use WinLoad to update the firmware punch out a hole when using the plastic enclosure Mounting G Use a screw with this hole to mount the IP100 in the metal box H Retractable flat mount brackets for optional wall mounting I Mount the IP100 on the top right corner of the metal box J Mounting screw B D A E C IP100 Connections IP100 Plastic Box G H H I Partial view of the metal box J IP Line Monitoring Options 5 6 OFF OFF Disabled OFF ON When disarmed Trouble on
4. Introduction The IP100 is an IP based Web solution that provides the ability to report system events to monitoring station over an IP network as well as an Internet communication link to control and monitor a security system Figure 1 Overview Installation Requirements To install and configure the IP100 the following hardware software will be needed Ethernet compatible computer with internet access for Remote Access only see reverse Router 4 pin serial cable included CAT 5 Ethernet cable max 90m 295 ft not included Paradox IP Exploring Tools software for Remote Access only see reverse found at paradox com gt GSM IP Voice gt IP100 Overview Connecting the Hardware The module must be connected to the control panel and a network The IP100 s error LED will light up until both the control panel and network are detected 1 Connect the 4 pin serial cable between the panel s serial connector and the IP100 s serial connector shown as D in Figure 2 2 Connect the Ethernet cable between the router and the IP100 s network connector shown as C in Figure 2 The router must be installed in the same room as the receiver 3 The onboard LEDs will illuminate to indicate the IP100 s status Figure 2 IP100 Connection IP Reporting Control panels with an IP100 can report system events to a monitoring station over an IP network To use IP reporting the monitoring station must employ the Paradox IP Rec
5. d to the device with that address Table 1 Technical Specifications Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on the Website www paradox com terms Your use of the Paradox product signifies your acceptance of all warranty terms and conditions EVO Digiplex EVO Magellan Spectra SP Esprit and Esprit E55 are trademarks or registered trademarks of Paradox Security Systems Ltd or its affiliates in Canada the United States and or other countries For the latest information on products approvals such as UL and CE please visit www paradox com 2009 Paradox Security Systems Ltd All rights reserved Specifications may change without prior notice One or more of the following US patents may apply 7046142 6215399 6111256 6104319 5920259 5886632 5721542 5287111 5119069 5077549 and RE39406 and other pending patents may apply Canadian and international patents may also apply This product includes software developed by Viola Systems http www violasystems com Copyright 2002 2002 Viola Systems Ltd All rights reserved Figure 3 Router Configuration Page Screenshot may differ depending on type of router used Figure 4 DHCP Settings Screenshot may differ depending on type of router used Figure 5 Port Forwarding Screenshot may differ depending on type of router used Figure 6 IP100 Configuration Access Figure 7 IP Address Assignment Fig
6. eiver IPR512 When using IP reporting the IP module has the ability to poll the monitoring station This supervision feature greatly increases the site s security In order for the IP100 to report to the monitoring station via IP connection the IP100 must first be registered to the monitoring station s IP Receiver IPR512 Telephone reporting can be used in conjunction with or as a backup to IP reporting Before registering the IP100 the following information must be obtained from the monitoring station Account number s One account number for each partition used IP GPRS reporting uses a different set of account numbers than those used fro dialer reporting The specific section numbers for the IP GPRS Account Numbers are listed in this document IP address es 12 digit number e g for 195 4 8 250 you must enter 195 004 008 250 The IP address es indicates which of the monitoring station s IP Receivers will be used for IP reporting IP port s 5 digit number For 4 digit numbers enter 0 before the first digit The IP port refers to the port used by the monitoring station s IP Receiver Receiver password s up to 32 digits The receiver password is used to encrypt the IP100 registration process Security profile s 2 digit number The security profile indicates how frequently the monitoring station is polled by the IP100 Security profile numbers and polling frequency are defined by the monitoring station Se
7. em set the Port to 80 and enter the static IP address selected in the previous step for the IP module see Figure 4 If port 80 is already used you can use another one such as 81 or 82 but you will have to modify the IP100 s settings in step 2 Some Internet Service Providers block port 80 therefore the IP100 may function locally using port 80 but not over the Internet If this is the case change the port to another number Repeat this step for port 10 000 Step 2 Configuring the IP100 1 Using a computer connected to the same network as the IP100 open the Paradox IP Exploring Tools 2 Click Find It Your IP100 appears in the list 3 Right click your IP100 and select Module setup see Figure 6 4 Enter the static IP address you recorded in Step 1 3 or modify the address so that it corresponds to the one you have selected for the IP100 Enter the IP100 s password default paradox and click OK If it indicates that the IP address is already used change it to another and modify it in the Port Forwarding of the router step 1 4 and go back to step 2 1 5 Set any additional information such as port subnet mask etc To find this information click Start gt Programs gt Accessories gt Command Prompt Enter command IPCONFIG ALL with space after IPCONFIG NOTE For increased communication security please change the default PC password and Panel ID in the control panel NOTE The IP100 supports SMTP and ESMTP p
8. ly When armed Trouble only ON OFF When disarmed Trouble only When armed Audible alarm ON ON Silent alarm becomes audible alarm OFF ON 7 Use dialer reporting telephone As backup for IP GPRS reporting In addition to IP reporting 8 IP GPRS reporting Disabled Enabled IP Line Monitoring Options 5 6 OFF OFF Disabled OFF ON When disarmed Trouble only When armed Audible alarm ON OFF When disarmed Trouble only default When armed Trouble only ON ON Silent alarm becomes audible alarm OFF ON 7 Use dialer reporting telephone As backup for IP GPRS reporting In addition to IP reporting 8 IP GPRS reporting Disabled Enabled MG SP E Sections IP Receiver 1 2 Backup IP Address1 929 936 943 IP Port1 930 937 944 IP Address2 931 938 945 IP Port2 932 939 946 IP Password 933 940 947 IP Profile 934 941 948 EVO Sections IP Receiver 1 2 3 4 IP Address1 2984 2986 2988 2990 IP Port1 IP Address2 IP Port2 IP Password IP Profile MG SP E Registration IP Receiver 1 2 Backup Register Status 935 942 949 EVO Registration IP Receiver 1 2 3 4 Register Status 2985 2987 2989 2991 Remote Access The IP100 is an IP based Web solution that provides an Internet communication link to control and monitor a security system with Web browsers or NEware This provides the user with the freedom to
9. ns If it is interrupted the IP100 will not be functional until the firmware is properly installed Glossary IP Reporting Using IP reporting system events are transmitted to the monitoring station via the Internet This method provides increased security due to frequent polling by the monitoring station IP Addresses Static Fixed or Dynamic Internet Protocol address The address of a device connected to an IP network This is equivalent to a phone number in the sense that they are all unique and are used to establish communication to a particular network In an IP network addresses can either be fixed or dynamic Fixed addresses are established by the network administrator while dynamic addresses are decided through DHCP protocols and change over time DHCP Dynamic Host Configuration Protocol This protocol automatically assigns temporary IP addresses to devices connected to an IP network It eliminates the need to set static IP addresses every time a device is added to a network This is done automatically in servers and routers Port Forwarding Port Forwarding allows a router in a private network to let a party outside the network to connect a device in the network Once port forwarding is set requests from the internet outside users will be forwarded to the proper device If you were to set the port number 80 HTTP to be forwarded to IP address 192 168 1 101 then all HTTP requests from outside users to this port would be forwarde
10. rotocols TLS SSL not supported Step 3 Setting up ParadoxMyHome optional This step is not needed if the IP address provided by the Internet Service Provider is static Using the ParadoxMyHome service will allow you to access your system over the Internet with a dynamic IP address The IP100 will then poll the ParadoxMyHome server to keep the information updated By default the ParadoxMyHome service is disabled To set up the ParadoxMyHome service 1 Go to www paradoxmyhome com click Request Login and provide the requested information 2 Start the Paradox IP Exploring Tools software and right click the IP100 3 Select Register to ParadoxMyHome 4 Enter the requested information Enter a unique SiteID for the module 5 When registration is complete you can access the IP100 page by going to www paradoxmyhome com SiteID If there are issues with connecting to the IP100 try making the polling delay shorter configured on the IP100 s webpage interface so that the IP information available for the ParadoxMyHome connection is up to date However a shorter delay for the polls will increase the traffic on the internet WAN Step 4 Using a Web Browser to Access the System Once the module is configured it can be accessed either from the local network or through the internet using the user code or user IP100 password On Site Access 1 Enter the IP address assigned to the IP100 in the address bar of your Web browser If you
11. tting up IP Reporting 1 Ensure that the panel s report code format is set to either Ademco Contact ID default or SIA MG SP E section 810 EVO section 3070 2 Enter the IP reporting account numbers one for each partition MG SP E section 918 919 EVO section 2976 to 2983 3 In the General IP Options section set up IP line monitoring options and dialer options and ensure IP reporting is enabled MG SP E section 806 EVO section 2975 4 Enter the monitoring station s IP address es IP port s receiver password s and security profile s information must be obtained from the monitoring station 5 Register the IP100 module with the monitoring station To register enter the sections below and press ARM The registration status is displayed as well as any registration errors NOTE An IP100 used with an MG SP E system will always poll using the partition 1 IP account number When using an EVO system the partition 1 IP account is used by default but can be defined in section 3020 All reported system events will originate from the partition selected in this section Connecting the Hardware IP Reporting Remote Access Step 1 Setting up the Router Step 2 Configuring the IP100 Step 3 Setting up ParadoxMyHome optional Step 4 Using a Web Browser to Access the System Firmware and Language Update Internet Module IP100 Instructions Version 1 5 PARADOX COM Printed in Canada 06 2009
12. ure 8 Module Registration Panel Compatibility Any Digiplex EVO panel V2 02 for IP reporting Any Spectra SP series panel V3 42 for IP reporting Any MG5000 MG5050 panel V4 0 for IP reporting Any Esprit E55 does not support IP reporting Esprit E65 V2 10 or higher Browser Requirements Optimized for Internet Explorer 6 or higher and Mozilla 1 5 or higher 1024 x 768 resolution minimum Encryption AES 256 bit MD5 and RC4 Current Consumption 110 mA Input Voltage Powered by the serial port Enclosure Dimensions 9 9cm x 7 2cm x 1 8cm 3 9in x 2 8in x 0 7in Figure 9 Firmware and Language Update Figure 10 Web update progress
Download Pdf Manuals
Related Search
Related Contents
PF-RJ104シリーズ 簡易取扱説明書 Manual de instruções StarTech.com PCI Express to ExpressCard Adapter - Front Bay ELASTOLIQUID - Index S.p.A. 15/07 - 日産自動車 Mode d`emploi des médicaments 61-20-00 CONTROLLING Mezclador Gravimetrico por Lotes con alimentadores de XRP7724 - Exar Corporation Copyright © All rights reserved.