Home

Leica Zeno 10/Zeno 15 User Manual

image

Contents

1. 108 Type ASO5 Voltage 4 5V to 18V DC Current 35 mA typical Frequency GPS L1 1575 42 MHz GLONASS L1 1602 5625 MHz 1611 5 MHz Gain typically 27 dBi Noise Figure typically 2 dBi Temperature Type Operating temperature C Storage temperature C ASO5 40 to 70 55 to 85 Protection against water dust and sand Type Protection ASO5 IP67 IEC 60529 Dust tight Protected against water jets Waterproof to 1 m temporary immersion Humidity Type Protection ASO5 Up to 100 96 The effects of condensation are to be effectively counter acted by periodically drying out the antenna Cable length Separation distance to antenna Supplied cable lengths m from instrument GS05 GS06 ASO5 1 2 Zeno 10 Zeno 15 Technical Data 109 Zeno 10 Zeno 15 Technical Data 110 6 5 Conformity to National Regulations 6 5 1 CS10 Conformity to e FCC Part 15 applicable in US national regula e Hereby Leica Geosystems AG declares that the product CS10 is in compliance tions with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity can be consulted at http www leica geosystems com ce Class 2 equipment according European Directive 1999 5 EC R amp TTE for which following EEA Member States apply restrictions on the placing on the market or on the putting into serv
2. Zeno 10 Zeno 15 Operation 53 Zeno 10 Zeno 15 Operation 3 3 3 Charge battery step by step Charging the Battery 5 024 Step Description 1 Connect the GEV235 power adapter or GDC221 car adapter with the CS field controller A or the docking station B and an A C plug 2 The power LED on the CS field controller switches on When CS field controller s battery is fully charged the LED switches off again Cg Refer to LED indicators for information about the power LED A Warning A Caution The following advice is only valid for battery charger power adapter and car adapter If you open the product either of the following actions may cause you to receive an electric shock e Touching live components e Using the product after incorrect attempts were made to carry out repairs Precautions Do not open the product Only Leica Geosystems authorised service workshops are entitled to repair these products The following advice is only valid for batteries power adapter or docking station The product is not designed for use under wet and severe conditions If unit becomes wet it may cause you to receive an electric shock Precautions Use the product only in dry environments for example in buildings or vehicles Protect the product against humidity If the product becomes humid it must not be used Zeno 10 Zeno 15 Operation 55 Zeno 10 Zeno
3. 3 2 Turning CS field controller on Turning CS field controller off Putting CS field controller into stand by Power Options menu Power Functions Press and hold power key C9 for 2 s Cg CS field controller must have a power supply Press and hold power key lt for 5 s CS CS field controller must be on Press and hold power key lt 8 lt 2 s Cg CS field controller must be on Press and hold power key C9 for 2 s to open Power Options menu Cg CS field controller must be on Option Description Turn off Turn CS field controller off Stand by Put CS field controller into stand by mode CS In stand by mode CS field controller shuts down and reduces power consumption Rebooting from stand by mode is quicker than a cold start after turning off Option Description Lock keyboard Lock the keyboard Option turns to Unlock keyboard Turn off touch screen Disable touch screen Option turns to Turn on touch screen Reset Perform one of the following options e Restart restarts Windows CE e Reset Windows CE resets Windows CE and communication settings to factory defaults e Reset installed software resets settings of all installed software s Reset Windows CE and installed software resets Windows CE and settings of all installed software Zeno 10 Zeno 15 Operation 49 Zeno 10 Zeno 15 Operati
4. Bluetooth Type Internal Microstrip antenna Gain 1 5 dBi Zeno 10 Zeno 15 Technical Data Zeno 10 Zeno 15 International Limited Warranty Software Licence Agreement 118 7 International Limited Warranty Software Li cence Agreement International This product is subject to the terms and conditions set out in the International Limited Warranty Limited Warranty which you can download from the Leica Geosystems home page at http www leica geosystems com internationalwarranty or collect from your Leica Geosystems distributor The foresoing warranty is exclusive and is in lieu of all other warranties terms or conditions expressed or implied either in fact or by operation of law statutory or otherwise including warranties terms or conditions of merchantability fitness for a particular purpose satisfactory quality and non infringement all which are expressly disclaimed Software Licence This product contains software that is preinstalled on the product or that is supplied Agreement to you on a data carrier medium or that can be downloaded by you online according to prior authorisation from Leica Geosystems Such software is protected by copy right and other laws and its use is defined and regulated by the Leica Geosystems Software Licence Agreement which covers aspects such as but not limited to Scope of the Licence Warranty Intellectual Property Rights Limitation of Liability Exclusion of other Assurances
5. VGA 640 x 480 pixels graphics capable LCD illumination touch screen colour 65 keys including 12 function keys illumination Toughened film on glass Dimensions Weight Recording Power Sound Digital camera Integrated sealed speaker and microphone Resolution 1600 x 1200 pixels fixed focus lens image capture JPEG Type Length m Width m Thickness m CS10 0 200 0 102 0 045 CS15 0 245 0 125 0 045 Type Weight kg Ibs CS10 with battery 0 688 1 517 CS15 with battery 0 838 1 847 memory Data can be recorded on the SD card CompactFlash card USB stick or in the internal Type Consumption W External supply voltage CS10 CS15 2 0 Nominal voltage 12 V DC Voltage range 10 5 V 28 V Zeno 10 Zeno 15 Technical Data 89 Zeno 10 Zeno 15 Technical Data 90 Internal battery Environmental specifications Type Battery Voltage Capacity Operating time typical CS10 CS15 Li lon 7 4M GEB212 2 6Ah 10h Operating time depends on use of wireless communication devices Temperature Type Operating temperature C Storage temperature C CS10 CS15 30 to 60 40 to 80 Internal 20 to 55 40 to 70 battery Protection against water dust and sand Type Protection CS10 CS15 IP67 IEC60529 Dust tight Waterproof to 1 m tem
6. 5 5 A Warning A Danger Hazards of Use The absence of instruction or the inadequate imparting of instruction can lead to incorrect or adverse use and can cause accidents with far reaching human material financial and environmental consequences Precautions All users must follow the safety directions given by the manufacturer and the direc tions of the person responsible for the product Because of the risk of electrocution it is dangerous to use poles and extensions in the vicinity of electrical installations such as power cables or electrical railways Precautions Keep at a safe distance from electrical installations If it is essential to work in this environment first contact the safety authorities responsible for the electrical instal lations and follow their instructions A Warning During dynamic applications for example stakeout procedures there is a danger of accidents occurring if the user does not pay attention to the environmental condi tions around for example obstacles excavations or traffic Precautions The person responsible for the product must make all users fully aware of the existing dangers Inadequate securing of the working site can lead to dangerous situations for example in traffic on building sites and at industrial installations Precautions Always ensure that the working site is adequately secured Adhere to the regulations governing safety and accident prevention a
7. GLONASS L1 1602 5625 1611 5 MHz Y GLONASS L2 1246 4375 1254 3 MHz Y Galileo E1 1575 42 MHz Galileo E5a 1176 45 MHz Type Galileo E5b 1207 14 MHz Galileo Alt BOC 1191 795 MHz GGO2 plus Gain Typically 27 dBi Noise Figure Typically 2 dBi Environmental Temperature specifications Operating temperature C Storage temperature C 40 to 65 Bluetooth 30 to 65 40 to 80 Protection against water dust and sand Protection IP67 IEC 60529 Dusttight Protected against water jets Waterproof to 1 m temporary immersion Zeno 10 Zeno 15 Technical Data 105 Zeno 10 Zeno 15 Technical Data 106 Humidity Protection Up to 100 The effects of condensation are to be effectively counteracted by periodically drying out the antenna 6 4 Description and use Dimensions Connector Mounting Weight Antennas Technical Data The table gives a description and the intended use of the antenna Type Description Use ASO5 L1 GPS GLONASS SmartTrack With CS10 GS05 CS15 GS06 antenna with built in ground plane Type ASO5 Height 6 2 cm Diameter 17 0 cm ASO5 TNC female ASO5 5 8 Whitworth ASO5 0 4 kg Zeno 10 Zeno 15 Technical Data 107 Zeno 10 Zeno 15 Technical Data Electrical data Environmental specifications
8. 15 Operation 56 3 4 Working with the Memory Device cg e Keep the card dry e Use it only within the specified temperature range e Do not bend the card e Protect the card from direct impacts cg Failure to follow these instructions could result in data loss and or permanent damage to the card Insert and remove a CompactFlash card step by step Step Description The CompactFlash card is inserted into a slot inside the top of the CS10 CS15 Refer to Fixing the slot cover to the CS step by step Loosen the screws inside the slot cover on top of the CS10 CS15 using the screwdriver end of the stylus Detach the slot cover from the CS10 CS15 UJ Slide the card firmly into the slot until it clicks into position CS Do not force the card into the slot The card must be held with the contacts facing the slot Attach the slot cover and tighten the screws To remove the card detach the slot cover of the CS10 CS15 Press the eject button next to the card slot twice bod No GRIS SS Remove the CompactFlash card and attach the slot cover Zeno 10 Zeno 15 Operation 57 Zeno 10 Zeno 15 Operation 58 Insert and remove an SD card step by step Step Description Cg The SD card is inserted into a slot inside the top of the CS10 CS15 l Refer to Fixing the slot cover to the CS step by step
9. 3 6 LED Indicators on GGO2 plus 62 3 7 Using the Digital Camera 64 4 Care and Transport 66 4 1 Transport 66 4 2 Storage 67 4 3 Cleaning and Drying 68 5 Safety Directions 69 5 1 General Introduction 69 5 2 Intended Use 70 5 3 Limits of Use 72 5 4 Responsibilities 73 5 5 Hazards of Use 74 5 6 Electromagnetic Compatibility EMC 80 5 7 FCC Statement Applicable in U S 83 6 Technical Data 88 6 1 CS10 CS15 Technical Data 88 6 2 GS05 GSO06 Technical Data 93 6 2 1 Tracking Characteristics 93 6 2 2 Accuracy 95 6 2 3 Technical Data 96 Zeno 10 Zeno 15 Table of Contents 9 Zeno 10 Zeno 15 Table of Contents 10 6 3 GGO2 plus Technical Data 99 6 3 1 Tracking Characteristics 99 6 3 2 Accuracy 101 6 3 3 Technical Data 103 6 4 Antennas Technical Data 107 6 5 Conformity to National Regulations 110 6 5 1 CS10 110 6 5 2 CS15 113 6 5 3 GGO2 plus 116 7 International Limited Warranty Software Licence Agreement 118 Appendix A Pin Assignments and Sockets 120 A l CS10 CS15 120 A 2 GGO2 plus 123 Index 125 Description of the System 1 1 Overview System compo nents GGO2 plus Zeno 10 Zeno 15 Description of the System 11 Zeno 10 Zeno 15 Description of the System 12 1 2 Terminology CS general descrip CS is a collective term describing the various models CS10 CS15 of the multi tion purpose field controller Zeno general Zeno is a collective term describing t
10. 68 4 3 Cleaning and Drying Product and acces lt Use only a clean soft lint free cloth for cleaning If necessary moisten the cloth sories with water or pure alcohol Do not use other liquids these may attack the polymer components Damp products Dry the product the transport container the foam inserts and the accessories at a temperature not greater than 40 C 104 F and clean them Do not repack until every thing is dry Always close the transport container when using in the field Cables and plugs eep plugs clean and dry Blow away any dirt lodged in the plugs of the connecting cables Connectors with Wet connectors must be dry before attaching the dust cap dust caps Safety Directions 5 1 General Introduction Description The following directions enable the person responsible for the product and the person who actually uses the equipment to anticipate and avoid operational hazards The person responsible for the product must ensure that all users understand these directions and adhere to them Zeno 10 Zeno 15 Safety Directions 69 Zeno 10 Zeno 15 Safety Directions 70 5 2 Intended Use Permitted use e Remote control of product e Data communication with external appliances Adverse use A Warning Use of the product without instruction Use outside of the intended limits Disabling safety systems Removal of hazard notices Opening the product using
11. CH 8435 Heerbrugg TMG a CES Made in Canada Labelling GGO2 plus This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harm ful interference and 2 this device must accept any interference received including inter ference that may cause undesired operation Power 12V nominal 1 0 5A max Leica Geosystems AG CH 9435 Heerbrugg xXx C Manufactured 2004 Made in Switzerland ZN 2 004 Zeno 10 Zeno 15 Safety Directions 85 Zeno 10 Zeno 15 Safety Directions 86 Labelling internal battery GEB211 GEB212 GEB 001 This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device C NEL Us LISTED must accept any interference received including interference that may cause undesired operation ITE Accessory E179078 70YL Exposure to radio The wireless device is a radio transmitter and receiver It is designed and manufac frequency RF tured not to exceed the emission limit for exposure to radio frequency RF energy signals set by the OET Bulletin 65 Supplement C Ministry of Health Canada Safety Code 6 These limits are part of comprehensive guidelines and established permitted levels of RF energy for the general population These guidelines are based on the safety standards
12. USB Mini port a j j DSUBO port UO 7 m Zeno 10 Zeno 15 Description of the System 23 Zeno 10 Zeno 15 Description of the System 24 Underside of CS15 Hand strap bottom clips Hand strap Battery compartment Digital camera Hand strap top clips Slots Slot cover Stylus GS06 contacts CompactFlash card slot SIM card slot SD card slot 1 5 Docking Station Components Docking station a b cj d e Power socket USB port Docking station bracket Docking station contacts GEV223 data cable Zeno 10 Zeno 15 Description of the System 25 Zeno 10 Zeno 15 User Interface 26 2 User Interface 2 1 Keyboard Keyboard display CS10 09 On cu va Cs 005 Home ON OFF Arrow keys OK Fn key Brightness Keyboard illumination Favourites ESC Enter Backspace Volume Numeric keys Keyboard display CS15 T Asaan Cs 006 0000000000 000000000 w2 09707070 0 070 CO 3 3 X o Home Arrow keys OK ON OFF Fn t key Numeric keys Brightness Keyboard illumination Function keys F7 F12 CAPS Lock Function keys F1 F6 Favourites ESC ENTER Backspace Volume Alpha keys ENTER SPACE Zeno 10 Zeno 15 User Interface 27 Zeno 10 Zeno 15 User Interface 28 Keys Key Function Function keys F1 F6 Correspond to six softkeys that appear on the bottom of the screen wh
13. aai verc t e n tn 28 AORA DIUSS cae reete re RR Rt REN ER PRE REN EPOR seme 62 Zeno 10 Zeno 15 Index 127 Zeno 10 Zeno 15 Index Description OT vs sin err rrr ren er aene 28 ENTER Key aee ice eee 29 acd Hx 28 Favourites aces nsa teme ether ed 29 Fn key Eunction Keys iiio eoe ree E 28 leuc iniaE 29 Hot Keys coste cett etam ertt trente 28 Numeric Keys 2s coiere in nnne s 28 OK T 30 ON OFF 29 SPACE ROUT sie este eedem 28 L Labelling CSTO pe EU CS 152 III e due eerte tiv Ea ee Mead Ete DP sen Ree GEB211 m GEB212 sh nb oed eden TEO PI E cm 85 ror 85 S06 rirse tr enne b ce Sene ere ER 85 LED CS10 description minirana aak 61 CS15 description os sas zaz x vya ernan aniani 61 GGO2 plus description sss eee eee 63 Light Emitting Diode CS TU renye Raa pa era dr redet ET 60 2 TP Em 60 GGO2 DIUS Ss as arte rir tr rs 62 Lilon Battehy aoc eio eec eene 104 StOFage cor i dt d e CRS eE Ed 67 M Memory device Available sine etn etin 19 Microsoft ActiveSync see 42 Mount anternnas onis hc raa i rar NENV aa ces 107 Mount GGO2 plus nett 103 0 Operating Temperature Antennas 5 nce es ier ana 108 CS LO Zatti ahaa io eei des 90 ESTS kt Mand ae tie po LE SML ecu DeC tiefe 90 GEB211 internal battery see 90 SD card GEB212 internal battery 90 SIM card GGO2 plus 105 Reset GSO Do cie tere ior d thee odiis daba dose oaa 98 Bose
14. 11 GEB212 battery OR Externally by docking station OR Externally by GEV235 cable OR Externally by GEV219 cable only CS models with LEMO CBCO1 connector module OR Externally by GDC221 car adapter If an external power supply is connected and the internal battery is inserted then the external power is used GS05 GS06 Externally by CS field controller GGO2 plus Internally by GEB211 GEB212 battery OR Externally by GEV219 cable If an external power supply is connected and the internal battery is inserted then the external power is used 1 3 3 Data Storage Concept Description Data is stored on a memory device The memory device can be an SD card Compact Flash card USB stick or internal memory Memory device SD card All CS field controllers have an SD card slot fitted as standard An SD card can be inserted and removed Available capacity 1GB CompactFlash card All CS field controllers have a CF card slot fitted as standard A CompactFlash card can be inserted and removed Available capacity 256 MB 1 GB USB stick All CS field controllers have a USB port fitted as standard Internal memory All CS field controllers have an internal memory fitted as standard Available capacity 1 GB Cg While other SD cards or CompactFlash cards can be used Leica Geosystems recommends to only use Leica SD cards or Leica CompactFlash cards and is not responsible for data loss or any other error that can oc
15. 2 ooo sees 90 cos R TTE 90 DOS E EET 92 CSR inen 90 Power SUDDIV a stave ton ree Dee eene dea deron reae 89 For internal battery GEB211 90 WRIST asns a en iere eco recede certe ce t ode 89 For internal battery GEB212 90 Temperature range GGO02 plis 3 3 oen EE 105 Prod ct drying optinere sacks 68 ESD emet etes ace col i bre ERE r 1 Ed 98 Temperature charging internal battery 50 S06 ischial CEU rU reu T to i IS nd 98 Touch screen Storing Temperature Turn off Antennas ces 108 Turn on Touch Screen operating principles 32 T Tracking LED Technical Data GGO2 plUS 455 tte rete E rente 62 C510 EEE 85 Transfer datas a science ne dente prete 20 GSTS R tere dds erede ei Ye 88 U Upload soar 1577 raar ene 922 Vez 2 5 9o 277 5ss 15 USB stick Memory device User Interface sse User Manual Validity Of scher ret rb t 4 V Volume Ip uro Meer TEM 31 linen ci Z cce d I 31 W Weight AMMO AS a 0 5 roosts merle KE n Tsa 107 GGO2 plus 103 GSO5 97 1506 Si HR HEE A 97 Windows CE Reset registry 49 ROSEAIT 2s ades ect ve pee be O re RT EE 49 Windows Mobile Device Center 42 AIGA ue S o sene eden eeu dee nue ua ce aaa deed 13 Z Zeno Available models Zeno 10 Zeno 15 Zeno 10 Zeno 15 Index 131 Total Quality Management Our commitment to total customer satisfaction 5 z Os ica Geosystems AG Heerbrugg Switzerland has b
16. 9 Zeno 10 Zeno 15 Safety Directions 80 5 6 Electromagnetic Compatibility EMC Description The term Electromagnetic Compatibility is taken to mean the capability of the product to function smoothly in an environment where electromagnetic radiation and elec trostatic discharges are present and without causing electromagnetic disturbances to other equipment A Warning Electromagnetic radiation can cause disturbances in other equipment Although the product meets the strict regulations and standards which are in force in this respect Leica Geosystems cannot completely exclude the possibility that other equipment may be disturbed The product is a class A product when operated with the internal batteries In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures A Caution A Caution A Warning There is a risk that disturbances may be caused in other equipment if the product is used with accessories from other manufacturers for example field computers personal computers two way radios non standard cables or external batteries Precautions Use only the equipment and accessories recommended by Leica Geosystems When combined with the product they meet the strict requirements stipulated by the guidelines and standards When using computers and two way radios pay attention to the information about electromagnetic compatibility provided by the manu
17. Connector GGO2 plus GSOS Chol 0 lo M Connector antennas sxs sn s sx ssa a ss ss sanga va 107 CS Available models sss 13 Display foil Docking Station 4i eene tzee 25 41 Firmware for all CS models l4 Lock keyboald tre 49 Operating principles ee eee 32 Power Options menu see eee e e e 48 Stand By mode netten 48 System components eee 11 Unlock keyboard eee 49 Zeno 10 Zeno 15 Index Zeno 10 Zeno 15 Index CS10 Operating temperature esses 90 Eccc 60 Storage temperature esses 90 Underside m WPSIGO I retain fered mee ete eerta edo CS15 Operating temperature esses 90 STEWS on ne eee eerte tra beet 60 Storage temperature 90 Underside 2G Upside arsa ex ae C eroe deae o adhe 23 D Data transfer ore pesce E ay 20 Description of the system eee 11 Digital Cariera i tete tenente de 64 Dimensions Antentias xs metet rime oleh ok a oe donate 107 sop 103 SmartAtntenrna cnin 96 Display foil 2 cheass the tess soca et erret 33 Docking Station Components e cepere ere pene epe 25 MOUNTING week eis ep BEER enan 41 Documentation reete doeet 4 Drive PC card on office computer ssss 20 E Electrical data GGO2 plis sons Moe etes ce
18. Governing Law and Place of Jurisdiction Please make sure that at any time you fully comply with the terms and conditions of the Leica Geosystems Software Licence Agreement Such agreement is provided together with all products and can also be referred to and downloaded at the Leica Geosystems home page at http www leica geosystems com swlicense or collected from your Leica Geosystems distributor You must not install or use the software unless you have read and accepted the terms and conditions of the Leica Geosystems Software Licence Agreement Installa tion or use of the software or any part thereof is deemed to be an acceptance of all the terms and conditions of such Licence Agreement If you do not agree to all or some of the terms of such Licence Agreement you must not download install or use the software and you must return the unused software together with its accompa nying documentation and the purchase receipt to the distributor from whom you purchased the product within ten 10 days of purchase to obtain a full refund of the purchase price Zeno 10 Zeno 15 International Limited Warranty Software Licence Agreement 119 Zeno 10 Zeno 15 Pin Assignments and Sockets 120 Appendix A A 1 Description Ports at the instru ment bottom panel DSUB9 connector Ports at the instru ment bottom panel Lemo connector Pin Assignments and Sockets CS10 CS15 Some applications require knowledge of the pin ass
19. In this chapter the pin assignments and sockets for the port of the GGO2 plus are explained Port at the instru ment underside a Lemo port USB and serial Zeno 10 Zeno 15 Pin Assignments and Sockets 123 Zeno 10 Zeno 15 Pin Assignments and Sockets 124 ji aiioe Pin Signal Name Function Direction a 1 USB D USB data line n or out 7 2 USB_D USB data line n or out 3 GND Signal ground S zs 4 RxD RS232 receive data n 5 TxD RS232 transmit data Out 6 ID Identification pin n or out 7 PWR Power input 10 5 V 28 V n 8 TRM ON USB ID RS232 general purpose signal n or out Sockets 8 pin LEMO 1 LEMO 1 8 pin LEMO EGI 1B 308 CLN Index A ACEVOSVEG eicit asiansa Desire sese deut ee aenee neus 42 Antennas s44 107 GGO02 DIUS acct rte etie eee tete 117 Operating Temperature eee eee eee 108 Storing Temperature TYDE site visite exeunte e e ep ute nen et cere ren Ar e EAA B Batteries Charge in CS10 CS15 sse 54 Charging first time use see ee 50 Operation Discharging sse 50 Battery Change in CS10 CS15 Charge in CS10 CS15 al internal GGOZ plus ce etes 104 Storage temperature oo eee ee eens 90 Bluetooth LED on CS10 LED on CS15 m LED on GGO2 plus eeeee 62 C CompactFlash card MIS OTS E E T eet 56 Memory device sss sees sees eee eee 19 REMOVE pre E ER 56
20. LAN 802 11b 48 Mbit s 56 Mbit s 31 6 Antenna Type Antenna Gain dBi Connector Frequency band MHz CS15 Bluetooth Integrated antenna CS15 Integrated 3 5G GSM UMTS antenna CS15 WLAN Integrated antenna GS06 Internal GNSS antenna element receive only Zeno 10 Zeno 15 Technical Data Zeno 10 Zeno 15 Technical Data 116 6 5 3 GGO2 plus Conformity to e FCC Part 15 22 and 24 applicable in US national regula e Hereby Leica Geosystems AG declares that the product GGO2 plus is in compli tions ance with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity can be consulted at http www leica geosystems com ce Class 1 equipment according European Directive 1999 5 EC R amp TTE C e can be placed on the market and be put into service without restric tions in any EEA member state e The conformity for countries with other national regulations not covered by the FCC part 15 22 and 24 or European directive 1999 5 EC has to be approved prior to use and operation Frequency band Type Frequency band MHz GGO2 plus 1227 60 1575 42 1246 4375 1254 3 1602 4375 1611 5 Bluetooth 2402 2480 Output power Antenna Type Output power mW GNSS Receive only Bluetooth 5 Class 1 GNSS Internal GNSS antenna element receive only
21. Leica Zeno 10 Zeno 15 User Manual Version 3 0 gran eica when it has to be right Geosystems Zeno 10 Zeno 15 Introduction 2 Introduction Purchase Congratulations on the purchase of a Leica Zeno 10 Zeno 15 This manual contains important safety directions as well as instructions for setting A PIN up the product and operating it Refer to 5 Safety Directions for further informa tion Read carefully through the User Manual before you switch on the product Product identifica The type and serial number of your product are indicated on the type plate tion Enter the type and serial number in your manual and always refer to this information when you need to contact your agency or Leica Geosystems authorised service work shop Type 0 22 Serial No Symbols The symbols used in this manual have the following meanings Type Description A Danger Indicates an imminently hazardous situation which if not avoided will result in death or serious injury A Warning Indicates a potentially hazardous situation or an unintended use which if not avoided could result in death or serious injury A Caution Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor or moderate injury and or appreciable material financial and environmental damage ee Important paragraphs which must be adhered to in practice as they enable th
22. Loosen the screws inside the slot cover on top of the CS10 CS15 using the screwdriver end of the stylus 2 Detach the slot cover from the CS10 CS15 3 Slide the card firmly into the slot until it clicks into position Do not force the card into the slot 4 The card must be held with the contacts facing the slot Step Description Attach the slot cover and tighten the screws To remove the card detach the slot cover of the CS10 CS15 Gently press the top of the card to release it from the slot 9 xo Remove the SD card and attach the slot cover Zeno 10 Zeno 15 Operation 59 Zeno 10 Zeno 15 Operation 60 3 5 LED Indicators on CS10 CS15 LED indicators Description The CS field controller has Light Emitting Diode indicators They indicate the basic field controller status Diagram a Bluetooth LED b Power LED Description of the LEDs IF the is THEN Bluetooth green Bluetooth is in data mode and ready for connecting LED purple Bluetooth is connecting blue Bluetooth has connected flashing blue data is being transferred Power LED off power is off green power is okay flashing green power is okay The battery is being charged yellow power is low The remaining time for which enoush power is available depends on the use of wireless modules the temperature and the age of the battery flashing yellow po
23. Q 5 4 Manufacturer of the product Manufacturers of non Leica Geosys tems accessories Person in charge of the product A Warning Responsibilities Leica Geosystems AG CH 9435 Heerbrugg hereinafter referred to as Leica Geosys tems is responsible for supplying the product including the user manual and original accessories in a safe condition The manufacturers of non Leica Geosystems accessories for the product are respon sible for developing implementing and communicating safety concepts for their products and are also responsible for the effectiveness of those safety concepts in combination with the Leica Geosystems product The person in charge of the product has the following duties e To understand the safety instructions on the product and the instructions in the user manual e To be familiar with local regulations relating to safety and accident prevention e To inform Leica Geosystems immediately if the product and the application becomes unsafe e TO ensure that the national laws regulations and conditions for the operation of radio transmitters are respected The person responsible for the product must ensure that it is used in accordance with the instructions This person is also accountable for the training and the deployment of personnel who use the product and for the safety of the equipment in use Zeno 10 Zeno 15 Safety Directions 73 Zeno 10 Zeno 15 Safety Directions 74
24. RE 49 GS OG cete Cx epi EG aT CU Hi HOM rd 98 Responsibilities sese 73 Output power GGO2 BUS afe uvis stage a eec n Safety Directions sese sees eee eee eee eee 69 P Satellite reception sissnnoninnineniini nutia 99 PC card drive on office computer 20 Screen brightness Piri Assginmerit 5 aci ot ntes tete 120 Decrease ias A a d eda ids 31 Power eq cri 31 GD Z IIE EE 103 SD card GS05 Ia EE GS06 Memory device Power LED Mee cR ax o ER 60 SIM card L E 60 pci dem M 37 GOGOZ plus a Reese ie eth ina AD 62 REMOVE Nit rc HE AT 37 Power supply 3 ede ee ee al add eee T8 SlobiCOVOl 5 eere Leo b ic adt 36 SOCKGT codes tute dre uten cei at eerie due nene eda 120 R l Software Recording 55 acte tret te tee tbe nes 89 Upload 2 2 cs Meum cos PU Ub cata 15 Remove Software Licence Agreement eee eee ee 118 CompactFlash card sese 56 Zeno 10 Zeno 15 Index 129 Zeno 10 Zeno 15 Index 130 Specifications environmental Display and keyboard eese 88 Aritennas e rie exe eee Environmental specifications 90 GS05 creen ee aar IE SEE NAPN ER SA E gere ster Ea AATA GGO2 plus uice opp EDS 99 GSO6 gt E GS05 Status CS10 0 5 GS06 Status CS IS 2 s atevuc cue cepe adeo cete Se tas a EURO Wterface coser ete Ern TTT 91 Status GGO02 Pls ca rper rene 62 nternal battery GEB211 oo 90 Storage Temperature nternal battery GEB21
25. Selects the highlighted line and leads to the next logical de menu dialog Starts the edit mode for editable fields Opens a selectable list Key combinations Key Function CRN a Hold Fn while pressing 4 Increase the screen bright ness RX a Hold Fn while pressing 7 Decrease the screen bright ness R Hold Fn while pressing 6 Increase the volume for acoustic warning signals beeps and keypresses on the CS field controller R 9 Hold Fn while pressing 9 Decrease the volume for acoustic warning signals beeps and keypresses on the CS field controller CN T Hold Fn while pressing 0 If keyboard illumination is already off Turns on keyboard illumination If keyboard illumination is already on Turns off keyboard illumination Zeno 10 Zeno 15 User Interface 31 Zeno 10 Zeno 15 User Interface 32 2 2 Keyboard and touch screen Operating Principles The user interface is operated either by the keyboard or by the touch screen with supplied stylus The workflow is the same for keyboard and touch screen entry the only difference lies in the way information is selected and entered Operation by keyboard Operation by touch screen nformation is selected and entered using the keys Refer to 2 1 Keyboard for a detailed description of the keys on the keyboard and their function nformation is selected and entered on the screen
26. a maximum number of 72 channels is allocated GPS Type L1 L2 GGO2 plus Carrier phase C A code Carrier phase C code L2C and P2 code GLONASS Type L1 L2 GGO2 plus Carrier phase C A code Carrier phase P2 code Zeno 10 Zeno 15 Technical Data 99 Zeno 10 Zeno 15 Technical Data 100 cg Carrier phase and code measurements on L1 L2 and L5 GPS are fully independent with AS on or off Satellites tracked GGO2 plus Up to 16 simultaneously on L1 L2 GPS up to 14 simultane ously on L1 and L2 GLONASS up to four SBAS EGNOS WAAS MSAS GAGAN 6 3 2 Differential code Differential phase in post processing Accuracy Accuracy is dependent upon various factors including the number of satellites tracked constellation geometry observation time ephemeris accuracy ionospheric disturbance multipath and resolved ambiguities The following accuracies given as root mean square are based on measurements processed using Zeno Office and on real time measurements The use of multiple GNSS systems can increase accuracy by up to 30 relative to GPS only The baseline precision of a differential code solution for static and kinematic surveys is 25 cm Static and rapid static Static Kinematic Horizontal Vertical Horizontal Vertical 5 mm T 0 5 ppm 10 mm T 0 5 ppm 10mm 2 ppm 20 mm T 2 ppm Zeno 10 Zeno 15 Technical Data 101 Z
27. ase C A code GLONASS Type L1 GS05 GS06 Carrier phase C A code cE Carrier phase and code measurements on L1 GPS are fully independent with AS on or off Up to 14 simultaneously on L1 GPS up to 14 simultaneously Satellites tracked GS05 GS06 on L1 GLONASS up to one SBAS 6 2 2 Accuracy cg Accuracy is dependent upon various factors including the number of satellites tracked constellation geometry observation time ephemeris accuracy ionospheric disturbance multipath and resolved ambiguities The following accuracies given as root mean square are based on measurements processed using LGO and on real time measurements The use of multiple GNSS systems can increase accuracy by up to 3096 relative to GPS only Differential code The baseline precision of a differential code solution for static and kinematic surveys is 40 cm Zeno 10 Zeno 15 Technical Data 95 Zeno 10 Zeno 15 Technical Data 96 6 2 3 Description and use Dimensions Connector Technical Data The table gives a description and the intended use of the GS05 GSO06 Type Description Use GSO05 L1 GPS GLONASS SmartTrack With CS10 field controller antenna GS06 L1 GPS GLONASS SmartTrack With CS15 field controller antenna Type Length m Width m Thickness m Zeno 10 0 278 0 102 0 045 GSO5 with CS10 Zeno 15 0 323 0 125 0 045 GSO6 with CS15 5 pin i
28. ct is not designed for use under wet and severe conditions If unit becomes wet it may cause you to receive an electric shock Precautions Use the product only in dry environments for example in buildings or vehicles Protect the product against humidity If the product becomes humid it must not be used A Warning If the product is improperly disposed of the following can happen e f polymer parts are burnt poisonous gases are produced which may impair health e f batteries are damaged or are heated strongly they can explode and cause poisoning burning corrosion or environmental contamination e By disposing of the product irresponsibly you may enable unauthorised persons to use it in contravention of the regulations exposing themselves and third parties to the risk of severe injury and rendering the environment liable to contamination Precautions The product must not be disposed with household waste Dispose of the product appropriately in accordance with the national regulations in force in your country Always prevent access to the product by unauthorised personnel Product specific treatment and waste management information can be downloaded from the Leica Geosystems home page at http www leica geosystems com treatment or received from your Leica Geosystems dealer A Warning Only Leica Geosystems authorised service workshops are entitled to repair these products Zeno 10 Zeno 15 Safety Directions 7
29. cur while using a non Leica card cg Removing the SD card CompactFlash card or USB stick while the CS field controller is turned on can cause loss of data Only remove the SD card CompactFlash card or USB stick or unplug connecting cables when the CS field controller is switched off Zeno 10 Zeno 15 Description of the System 19 Zeno 10 Zeno 15 Description of the System 20 Transfer data Se Data can be transferred in various ways Refer to 3 1 7 Connecting to a Personal Computer CompactFlash cards and SD cards can directly be used in an OMNI drive as supplied by Leica Geosystems Other PC card drives can require an adaptor 1 4 CS Components 1 4 1 CS10 Upside of CS10 a Slot Cover b Screen c Keyboard d Port cover e Power socket f USB A Host port g Docking station contacts h LEMO port USB and serial i USB Mini port ex j j DSUBO port Zeno 10 Zeno 15 Description of the System 21 Zeno 10 Zeno 15 Description of the System 22 Underside of CS10 Hand strap bottom clips Hand strap Battery compartment Digital camera Hand strap top clips Slots Slot cover Stylus GS05 contacts CompactFlash card slot SIM card slot SD card slot 1 4 2 CS15 Upside of CS15 ow d a Slot cover b Screen c Keyboard d Port cover e Power socket f USB A Host port g Docking station contacts h LEMO port USB and serial E
30. d leica geosystems com Refer to Introduction Connect the CS field controller to your PC Refer to 3 1 7 Connecting to a Personal Computer Copy GS firmware file onto a folder on the Leica SD card Leica CompactFlash card or USB stick Click on Start Programs Zeno Tools Firmware to run the Firmware loader application Browse to the directory into which you copied GS firmware file select it and start the upload Software for Description GGO2 plus The software is stored in the flash RAM of the GGO2 plus GG firmware update instructions Download the most recent GG firmware file from https myworld leica geosystems com Refer to Introduction Copy GG firmware file onto a PC with Leica Zeno Field installed Connect the GGO2 plus with the GEV234 cable to the PC Refer to 3 1 7 Connecting to a Personal Computer Click on Start Programs Zeno Tools Firmware to run the Firmware loader application Browse to the directory into which you copied GG firmware file select it and start the upload Zeno 10 Zeno 15 Description of the System 17 Zeno 10 Zeno 15 Description of the System 18 1 3 2 General Power options Power Concept Use the Leica Geosystems batteries chargers and accessories or accessories recom mended by Leica Geosystems to ensure the correct functionality of the instrument Model Power supply all CS models Internally by GEB2
31. e product to be used in a technically correct and efficient manner Zeno 10 Zeno 15 Introduction Zeno 10 Zeno 15 Introduction 4 Trademarks Validity of this manual Available documentation e Windows is a registered trademark of Microsoft Corporation in the United States and other countries e CompactFlash and CF are trademarks of SanDisk Corporation e Bluetooth is a registered trademark of Bluetooth SIG Inc SD is a trademark of the SD Card Association All other trademarks are the property of their respective owners This manual app between the var ies to the Zeno 10 and Zeno 15 GNSS GIS handhelds Differences ious models are marked and described Name Description Format Zeno 10 Zeno All instructions required in order to operate the product Y lt Started Guide 15 User to a basic level are contained in the User Manual Manual Provides an overview of the product together with tech nical data and safety directions Name Description Format 3 z Zeno GIS Describes the general working of the product in Y Getting standard use Intended as a quick reference field guide m world Leica Geosystems Name Description Format ps z Zeno GIS Help Overall comprehensive help to the product and applica tion functions Included are detailed descriptions of special software hardware settings and software hard ware function
32. een o ES certified as being equipped with a quality system which ra Ba T Lost Q IVI meets the International Standards of Quality Management 2 and Quality Systems ISO standard 9001 and Environmental S ISO 9001 1SO 14001 Management Systems ISO standard 14001 S S M Ask your local Leica Geosystems dealer for more information about our TQM program 2011 Leica Geosystems AG Heerbrugg Switzerland Leica Geosystems AG Heinrich Wild Strasse CH 9435 Heerbrugg e Switzerland when it has to be right CU Phone 41 71 727 31 31 www leica geosystems com Geosystems
33. en the screen is activated Function keys F7 F12 User definable keys to execute chosen commands or access chosen screens Alpha keys To type letters Numeric keys To type numbers Caps Lock Switches between upper case and lower case letters Backspace Clears all entry at the beginning of user input Clears the last character during user input Esc Leaves the current screen without storing any changes Fn Switches between the first and second level of func tion keys Space Enters a blank Dl 4 9 eel ele Key Function Enter Selects the highlighted line and leads to the next logical menu dialog Starts the edit mode for editable fields Opens a selectable list ON OFF If CS10 CS15 already off Turns on CS10 CS15 when held for 2 s If CS10 CS15 in stand by mode Turns on CS10 CS15 when held 2 s If CS10 CS15 already on e Puts CS10 CS15 into stand by mode when held 2s Refer to Putting CS field controller into stand by Turns to Power Options menu when held for 2 s Refer to Power Options menu e Turns off CS10 CS15 when held for 5 s Favourites Goes to a website by simply clicking its name Home MI Switches to the Windows CE Start Menu Zeno 10 Zeno 15 User Interface 29 Zeno 10 Zeno 15 User Interface 30 Key Function Arrow keys lt p Move the focus on the screen ves gt OK
34. eno 10 Zeno 15 Technical Data 102 Differential phase in real time Static with long observations Static Kinematic Horizontal Vertical Horizontal Vertical 3 mm 0 5 ppm 6 mm 0 5 ppm 10 mm 2 ppm 20 mm T 2 ppm Static Kinematic Horizontal Vertical Horizontal Vertical 5 mm T 0 5 ppm 10 mm 0 5 ppm 10 mm 2 ppm 20 mm T 2 ppm 6 3 3 Description and use Dimensions Connector Mounting Weight Power Technical Data The table gives a description and the intended use of the GGO2 plus Type Description Use GGO2 plus L1 L2 GPS GLONASS antenna With CS10 CS15 or CS25 field controller Height 0 089 m Diameter 0 186 m e 8 pin LEMO 1 5 8 Whitworth 1 1 kg including internal battery Power consumption 1 8 W typically External supply voltage Nominal 12 V DC voltage range 10 5 V 28 V Zeno 10 Zeno 15 Technical Data 103 Zeno 10 Zeno 15 Technical Data 104 Battery internal Type Li lon Voltage 7 9 V Capacity GEB211 2 2 Ah GEB212 2 6 Ah Typical operating time 7h The given operating times are valid for e one fully charged GEB212 battery e 25 C Operating times will be shorter when working in cold weather Electrical data Type GGO02 plus Frequency GPS L1 1575 42 MHz Y GPS L2 1227 60 MHz Y GPS L5 1176 45 MHz S
35. es the person in charge of the product must ensure that the applicable national and international rules and regulations are Observed Before transportation or shipping contact your local passenger or freight transport company High mechanical stress high ambient temperatures or immersion into fluids can cause leakage fire or explosions of the batteries Precautions Protect the batteries from mechanical influences and high ambient temperatures Do not drop or immerse batteries into fluids If battery terminals come in contact with jewellery keys metallised paper or other metals short circuited battery terminals can overheat and cause injury or fire for example by storing or transporting in pockets Precautions Make sure that the battery terminals do not come into contact with metallic objects The following advice is only valid for battery charger power adapter and car adapter Zeno 10 Zeno 15 Safety Directions 77 Zeno 10 Zeno 15 Safety Directions 78 A Warning A Caution If you open the product either of the following actions may cause you to receive an electric shock e Touching live components Using the product after incorrect attempts were made to carry out repairs Precautions Do not open the product Only Leica Geosystems authorised service workshops are entitled to repair these products The following advice is only valid for batteries power adapter or docking station The produ
36. fac turer Disturbances caused by electromagnetic radiation can result in erroneous measure ments Although the product meets the strict regulations and standards which are in force in this respect Leica Geosystems cannot completely exclude the possibility that the product may be disturbed by intense electromagnetic radiation for example near radio transmitters two way radios or diesel generators Precautions Check the plausibility of results obtained under these conditions If the product is operated with connecting cables attached at only one of their two ends for example external supply cables interface cables the permitted level of electromagnetic radiation may be exceeded and the correct functioning of other products may be impaired Zeno 10 Zeno 15 Safety Directions 81 Zeno 10 Zeno 15 Safety Directions 82 Radios or digital cellular phones A Warning Precautions While the product is in use connecting cables for example product to external battery product to computer must be connected at both ends Use of product with radio or digital cellular phone devices Electromagnetic fields can cause disturbances in other equipment in installations in medical devices for example pacemakers or hearing aids and in aircraft It can also affect humans and animals Precautions Although the product meets the strict regulations and standards which are in force in this respect Leica Geosystems cannot com
37. ftware type Description GG firmware GG_xx fw This software includes The firmware for the measurement engine Software upload CS Uploading firmware can take some time Ensure that the battery is at least 7596 full before beginning the upload and do not remove the battery during the upload process Software for Description All CS models The software is stored in the flash RAM of the CS field controller CS firmware update instructions Download the most recent CS firmware file from https myworld leica geosystems com Refer to Introduction e Connect the CS field controller to your PC Refer to 3 1 7 Connecting to a Personal Computer e Copy CS firmware file onto a folder on the Leica SD card Leica CompactFlash card or USB stick e Tap the Loader icon from the desktop to run the Loader application e Browse to the directory into which you copied CS firmware file select it and start the upload e Amessage will appear when the upload is complete CS Ensure that a Leica SD card or a Leica CF card is inserted into the CS field controller before starting the upload Zeno 10 Zeno 15 Description of the System 15 Zeno 10 Zeno 15 Description of the System 16 Software for Description GS05 GS06 The software is stored in the flash RAM of the GS05 GSO6 GS firmware update instructions Download the most recent GS firmware file from https myworl
38. have to be smoothed out using the included microfibre cloth Cg Do not use sharp objects 3 1 2 Fixing a Hand Strap to the CS Fixing the CS to a hand strap step by step Description Turn the CS field controller over Take the end of the hand strap and clip it to the base of CS field controller Compress the clips of the main hook Lower the main hook onto the pivot knob of the CS field controller A click can be felt when the clip is secure Adjust the length of the hand strap Zeno 10 Zeno 15 Operation 35 Zeno 10 Zeno 15 Operation 36 3 1 3 Fixing the Slot Cover to the CS Fixing the slot cover to the CS step by step Step Description L Press the screwdriver end of the supplied stylus on the quarter turn screws and loosen them 2 Remove the slot cover Cg Reattach the slot cover with the stylus making sure the quarter turn screws are seated 3 1 4 Inserting and Removing a SIM Card Insert and remove a SIM card step by step Description Cg The SIM card is inserted into a slot inside the top of the CS10 CS15 T Loosen the screws inside the slot cover on top of the CS10 CS15 using the screwdriver end of the stylus 2 Detach the slot cover from the CS10 CS15 3 Slide the card firmly into the slot until it clicks into position Cg Do not force the card into the slot T
39. he card should be held with the contacts facing the slot Zeno 10 Zeno 15 Operation 37 Zeno 10 Zeno 15 Operation 38 Description Attach the slot cover and tighten the screws To remove the card detach the slot cover of the CS10 CS15 Gently press the top of the card to release it from the slot poy Sys Remove the SIM card and attach the slot cover 3 1 5 Setting up as Handheld GNSS I The setup GS05 CS10 is identical to the setup GS06 CS15 For simplicity the setup GS05 CS10 is used in the following Attaching the GSO5 to the CS10 step by step con Step Description CS Detach the slot cover from the CS10 Refer to 3 1 3 Fixing the Slot Cover to the CS Check the position of the contacts in the inner surface of the GSO5 Zeno 10 Zeno 15 Operation 39 Zeno 10 Zeno 15 Operation 40 Step Description 2 Attach the GSO5 to the CS10 3 Press the screwdriver end of the supplied stylus on the quarter turn screws and tighten them To achieve the optimal satellite tracking performance mount the ASO5 external GNSS antenna on the GSO5 3 1 6 Setting up the Docking Station Mounting compo nents of the docking station step by step Step Description Hold the docking station bracket as shown in the illustration in relation to the docking station
40. he various models Zeno 10 Zeno 15 of the description Leica Zeno GNSS GIS handhelds e Leica Zeno 10 GNSS GIS handheld consisting of CS10 field controller and GS05 GNSS cap e Leica Zeno 15 GNSS GIS handheld consisting of CS15 field controller and GS06 GNSS cap e Leica Zeno Rover GNSS GIS rover consisting of CS10 CS15 field controller and GGO2 plus antenna CS available gt ri is models z x V a E K 2 OE 2 v z m o a in U T q lel 2 v m E O Ya LS on J 5 o v 8 un 2 l lasl l2 la I5 s PR 9 S 3 Eu E la Te R 243 9 S o ok g V E 7 KU o 3 EGE em 2ele la ke l2 o G o 55 a JO m Sel CS10 GIS Y Y Y Y v 4 Y CS10 3 5G GIS Y Y Y Y Y v v Y Y CS15 GIS Y Y Y v Y 4 S Y CS15 3 5G GIS Y Y Y Y v v v Y Y CE Use the supplied stylus on the screens of the touch screen 1 removable Zeno 10 Zeno 15 Description of the System 13 Zeno 10 Zeno 15 Description of the System 1 3 1 3 1 Software for all CS models Software for the GS05 GSO6 Software for the GGO2 plus System Concept Software Concept Software type Description CS firmware CS o fw This software includes The language specific version of Windows CE The basic functionality of the CS Software type Description GS firmware GS x fw This software includes The firmware for the measurement engine So
41. ice or require authorisation for use e France e Italy e Norway if used in the geographical area within a radius of 20km from the centre of Ny Alesund e The conformity for countries with other national regulations not covered by the FCC part 15 or European directive 1999 5 EC has to be approved prior to use and operation Frequency band Type Frequency band MHz CS10 Bluetooth 2402 2480 CS10 3 5G GSM UMTS UMTS HSDPA WCDMA FDD 850 1900 2100 Quad Band EGSM 850 900 1800 1900 GPRS multi slot class 12 EDGE multi slot class 12 CS10 WLAN 2400 2484 Output power Type Output power mW CS10 Bluetooth 25 CS10 3 5G GSM UMTS EGSM850 900 2 CS10 3 5G GSM UMTS GSM1800 1900 1 CS10 3 5G GSM UMTS UMTS2100 0 25 CS10 3 5G GSM UMTS EDGE850 900 0 5 CS10 3 5G GSM UMTS EDGE1800 1900 0 4 CS10 WLAN 802 11b 50 CS10 WLAN 802 11g 6 Mbit s 36 Mbit s 50 CS10 WLAN 802 11b 48 Mbit s 56 Mbit s 31 6 Zeno 10 Zeno 15 Technical Data Zeno 10 Zeno 15 Technical Data 112 Antenna Type Antenna Gain dBi Connector Frequency band MHz CS10 Bluetooth Integrated antenna CS10 Integrated 3 5G GSM UMTS antenna CS10 WLAN Integrated antenna GS05 Internal GNSS antenna element receive only 6 5 2 CS15 Conformity to e FCC Part 15 applicable in US national regula e Hereby Leica Geo
42. ignments for the CS10 CS15 ports In this chapter the pin assignments and sockets for the ports of the CS10 CS15 are explained a DSUBO port b USB Mini port com a b c c USB A Host port a Lemo port USB and serial con a b b USBA Host port Pin assignments Pin Signal Name Function Direction for RS232 serial port 1 NC ot connected s f 2 RxD RS232 receive data In US 20 30 405 sereseve 3 TxD RS232 transmit data Out RUE 4 NC ot connected 5 GND Signal Ground 6 NC Not connected 7 RTS RS232 request to send Out 8 CTS RS232 clear to send In 9 NC ot connected Zeno 10 Zeno 15 Pin Assignments and Sockets 121 Zeno 10 Zeno 15 Pin Assignments and Sockets 122 ji aiioe Pin Signal Name Function Direction F 1 USB_D USB data line n or out 7 2 USB_D USB data line n or out 3 GND Signal ground S zs 4 RxD RS232 receive data n 5 TxD RS232 transmit data Out 6 ID Identification pin n or out 7 PWR Power input 10 5 V 28 V n 8 TRM ON USB ID RS232 general purpose signal n or out Sockets 9 pin RS232 RS232 9 pin DE9 8 pin LEMO 1 LEMO 1 8 pin LEMO EGI 1B 308 CLN A 2 GGO2 plus Description Some applications require knowledge of the pin assignments for the GGO2 plus port
43. nd road traffic If computers intended for use indoors are used in the field there is a danger of elec tric shock Precautions Adhere to the instructions given by the computer manufacturer regarding field use with Leica Geosystems products Zeno 10 Zeno 15 Safety Directions 75 Zeno 10 Zeno 15 Safety Directions 76 If the accessories used with the product are not properly secured and the product is subjected to mechanical shock for example blows or falling the product may be damaged or people can sustain injury Precautions When setting up the product make sure that the accessories are correctly adapted fitted secured and locked in position Avoid subjecting the product to mechanical stress If the product is used with accessories for example masts staffs poles you may increase the risk of being struck by lightning Precautions Do not use the product in a thunderstorm Using a battery charger not recommended by Leica Geosystems can destroy the batteries This can cause fire or explosions Precautions Only use chargers recommended by Leica Geosystems to charge the batteries A Caution During the transport shipping or disposal of batteries it is possible for inappropriate mechanical influences to constitute a fire hazard Precautions Before shipping the product or disposing of it discharge the batteries by running the product until they are flat When transporting or shipping batteri
44. ns 104 Electrical Data GSO5 GS O06 vrs incon Electrical data antennas eee 108 Environmental specifications ANTENNS s coda s na CORR PO a 108 GGO2 pl s A cerent teretes 105 GS05 GS06 F FGG Statement iios saepe ice ctr eee SN 2 eea 83 Firmware for GGO2 plUS sse eee l4 Frequency band GGO2 lU cmt omoes eec ae 116 G Insert GEB211 internal battery CompactFlash card i 56 Operating temperature eee ee eee 90 SDcard ef tee teh etre vada tee 58 GEB212 internal battery ger adn 37 Operating temperature e 00 Intended Use oem e eee eg 70 GGO2 plus Internal memory Stats caret Ret t e s vane 62 Memory device sss sees seer eee 19 GS International Limited Warranty 118 Firmware for GS05 GS06 see eee l4 K GS05 As Operating Temperature ee gg Key combinations Storage Temperature 98 Description OF cane mue ru tbt 31 GS06 Keyboard Operating Temperature see eee eee eee 98 C510 Graphical OVSIVICU sciatis meridies Storage Temperature ee 98 C515 Graphical overview Operating principles eee H Keyboard illumination Hand StEp 3 etre TE ced ret ede rere 35 TUPI OR iacit RR ease then 31 Handheld GNSS wis t nt eite terere th 39 TURM OFT 6d drca Cet etr aede Hace oett 31 Keys l Alpes aT 28 Indicators LED ATOW K YS occccesescsssesesessescseseceescsceestescetsceeees 30 OS PO TT 60 Backspace key ccccccccsesssesesesesesesesssestsceereneees 28 C515 e Caps Lock vs
45. nterface port Weight Type Weight kg Ibs Zeno 10 GS05 with CS10 0 750 1 653 Zeno 15 GS06 with CS15 0 910 2 006 Power Power consumption 0 5 W typically 45 mA External supply voltage ominal 12 V DC voltage range 5 V 28 V DC Electrical data Type GS05 GS06 Voltage Current Frequency GPS L1 1575 42 MHz GLONASS L1 1602 5625 MHz 1611 5 MHz Gain Typically 27 dBi Noise Figure Typically 2 dBi Zeno 10 Zeno 15 Technical Data 97 Zeno 10 Zeno 15 Technical Data Environmental Temperature specifications Operating temperature C Storage temperature C 30 to 60 40 to 80 Protection against water dust and sand Protection IP67 IEC 60529 Dust tight Protected against water jets Waterproof to 1 m temporary immersion Humidity Protection Up to 100 The effects of condensation are to be effectively counteracted by periodically drying out the antenna 6 3 6 3 1 Satellite reception Instrument chan nels Supported codes and phases GGO2 plus Technical Data Tracking Characteristics GGO2 plus Dual frequency GGO2 plus Up to 16 channels continuous tracking on L1 L2 GPS up to 14 channels continuous tracking on L1 and L2 GLONASS four channels tracking SBAS EGNOS WAAS MSAS GAGAN Cg Depending on the satellite systems and signals configured
46. on 50 3 3 3 3 1 Charging first time use Operation Discharging Batteries Operating Principles e The battery must be charged prior to using it for the first time because it is deliv ered with an energy content as low as possible e The permissible temperature range for charging is between 0 C to 40 C 32 F to 104 F For optimal charging we recommend charging the batteries at a low ambient temperature of 10 C to 20 C 50 F to 68 F if possible e Itis normal for the battery to become warm during charging Using the chargers recommended by Leica Geosystems it is not possible to charge the battery if the temperature is too high e For new batteries or batteries that have been stored for a long time gt three months it is effectual to make only one charge discharge cycle e For Li lon batteries a single discharging and charging cycle is sufficient We recommend carrying out the process when the battery capacity indicated on the charger or on a Leica Geosystems product deviates significantly from the actual battery capacity available e The batteries can be operated from 20 C to 55 C 4 F to 131 F Low operating temperatures reduce the capacity that can be drawn high oper ating temperatures reduce the service life of the battery 3 3 2 Changing the Battery Insert and remove the battery on the CS field controller step by step c5 010 Step Description Tu
47. ort container and secure it When transporting the product by rail air or sea always use the complete original Leica Geosystems packaging transport container and cardboard box or its equiva lent to protect against shock and vibration When transporting or shipping batteries the person in charge of the product must ensure that the applicable national and international rules and regulations are Observed Before transportation or shipping contact your local passenger or freight transport company 4 2 Storage Product Respect the temperature limits when storing the equipment particularly in summer if the equipment is inside a vehicle Refer to 6 Technical Data for information about temperature limits Li lon batteries e Refer to 6 Technical Data for information about storage temperature range e AL the recommended storage temperature range batteries containing a 10 to 5096 charge can be stored for up to one year After this storage period the batteries must be recharged e Remove batteries from the product and the charger before storing e After storage recharge batteries before using e Protect batteries from damp and wetness Wet or damp batteries must be dried before storing or use e A storage temperature range of 20 C to 30 C 4 F to 86 F in a dry environ ment is recommended to minimise self discharging of the battery Zeno 10 Zeno 15 Care and Transport 67 Zeno 10 Zeno 15 Care and Transport
48. our PC Cg For PCs with Windows Vista or Windows 7 operating system If not already installed Windows Mobile Device Center will be installed additionally The InstallShield Wizard Completed window appears Check I have read the instructions and click Finish to exit the wizard Zeno 10 Zeno 15 Operation 43 Zeno 10 Zeno 15 Operation 44 Connect USB cable to PC for the first time step by step Step Description 1 Start the PC 2 Plug the GEV234 cable into CS field controller Cg For CS field controllers with DSUB9 connector the GEV223 cable has to be used 3 Turn on the CS field controller 4 Plug the GEV234 cable into the USB port of the PC The Found New Hard ware Wizard starts up automatically 5 Check Yes this time only Next gt Step Description Check Install the software automatically Recommended Next gt The software for Remote NDIS based LGS CS Device will be installed on your PC Finish The Found New Hardware Wizard starts up automatically a second time Check Yes this time only Next gt 10 Check Install the software automatically Recommended Next gt The software for LGS CS USB Device will be installed on your PC 11 Finish For PCs with Windows XP operating system 12 Run the ActiveSync installation program if not already installed 13 Allow USB connections in
49. picture step by step Using the Digital Camera Both CS field controllers are equipped with a digital camera located at the underside refer to 1 4 CS Components If a hand strap or pole holder plate is mounted the camera view is not limited The camera application can be started from the desktop icon Camera or from the Start menu Start Programs Camera Step Description I Aim the camera to the desired target 2 Check the view at the display 3 Press OK or click Capture to take the picture CS Capture changes to Save 4 Press OK again or click Save to open the Save As dialog 5 Click Discard to reject the picture Storing a picture Step Description step by step The Save As dialog is Windows CE standard and allows to name the picture choose the location or to create a folder Browse to the desired folder or create a new one Name the picture Press OK to save it and return to the camera view EI W RM e Press Cancel to reject the picture and to return to the camera view without saving the picture Zeno 10 Zeno 15 Operation 65 Zeno 10 Zeno 15 Care and Transport 66 4 4 1 Transport in a road vehicle Shipping Shipping transport of batteries Care and Transport Transport Never carry the product loose in a road vehicle as it can be affected by shock and vibration Always carry the product in its transp
50. pletely exclude the possibility that other equipment can be disturbed or that humans or animals can be affected e Do not operate the product with radio or digital cellular phone devices in the vicinity of filling stations or chemical installations or in other areas where an explosion hazard exists e Do not operate the product with radio or digital cellular phone devices near to medical equipment e Donotoperate the product with radio or digital cellular phone devices in aircraft 5 7 FCC Statement Applicable in U S cg The greyed paragraph below is only applicable for products without radio A Warning This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interfer ence in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfer ence to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encour aged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving an
51. porary immersion Interfaces Data format for RS232 Humidity Type Protection CS10 CS15 Up to 100 The effects of condensation are to be effectively counteracted by periodically drying out CS10 CS15 Type RS232 USB Host USB OTG Bluetooth WLAN CS10 CS15 LEMO port or LEMO port or LEMO port Class 2 802 11b g DSUB9 USB A USB Mini AB or docking station contacts The default values are Baud rate Parity Terminator Data bits Stop bits 115200 None CR LF 8 1 Zeno 10 Zeno 15 Technical Data 91 Zeno 10 Zeno 15 Technical Data 92 Ports Type 8 pin LEMO 1 DSUB9 USBA USB Mini Docking station Host contacts CS10 CS15 For power and or For communication For power and or communication communication 6 2 6 2 1 Instrument tech nology Satellite reception Instrument chan nels GS05 GSO6 Technical Data Tracking Characteristics SmartTrack Single frequency GS05 GS06 Up to 14 channels continuous tracking on L1 GPS up to 14 channels continuous tracking on L1 GLONASS one channel tracking SBAS CE Depending on the satellite systems and signals configured a maximum number of 14 channels is allocated Zeno 10 Zeno 15 Technical Data 93 Zeno 10 Zeno 15 Technical Data 94 Supported codes GPS and phases Type L1 GS05 GS06 Carrier ph
52. previously set by international standard bodies These standards include a substantial safety margin designed to assure the safety of all persons regardless of age and health This device and its antenna must not be co located or operating in conjunction with any other antenna or transmitter This device has been shown to be capable of compliance for localised specific absorp tion rate SAR for uncontrolled environment general public exposure limits specific in ANSI IEEE C95 1 1992 and had been tested in accordance with the measurement procedures specified in IEEE Std 1528 2003 SAR compliance for body worn operating configurations is limited to specific belt clips holsters or similar accessory configurations that have no metallic component in the assembly providing at least 1 0 cm separation distance between the device and the body of the user Zeno 10 Zeno 15 Safety Directions 87 Zeno 10 Zeno 15 Technical Data 88 6 6 1 Design Control unit Technical Data CS10 CS15 Technical Data Glass reinforced polymer housing with optional integrated battery CS10 Display Keyboard Touch screen Sound Digital camera CS15 Display Keyboard Touch screen VGA 480 x 640 pixels graphics capable LCD illumination touch screen colour 26 keys illumination Toughened film on glass Integrated sealed speaker and microphone Resolution 1600 x 1200 pixels fixed focus lens image capture JPEG
53. rack Slightly press the holder into the docking station rack A click can be felt when the holder is secure Zeno 10 Zeno 15 Operation 41 Zeno 10 Zeno 15 Operation 42 3 1 7 Connecting to a Personal Computer cE Microsoft ActiveSync for PCs with Windows XP operating system or Windows Mobile Device Center for PCs with Windows Vista or Windows 7 operating system is the synchronisation software for Windows mobile based pocket PCs Microsoft Active Sync or Windows Mobile Device Center enables a PC and a Windows mobile based pocket PC to communicate Install Leica Viva Step Description USB drivers T Start the PC 2 Insert the Leica Viva Series DVD 3 Run the SetupViva amp GR_USB_XX exe to install the drivers necessary for Leica Viva devices Depending on the version 32bit or 64bit of the oper ating system on your PC you have to select between the three setup files following e SetupViva amp GR USB 32bit exe e SetupVivaS GR USB 6 bit exe e SetupVivaS GR USB 64bit itanium exe Cg The setup has to be run only once for all Leica Viva devices Step Description The Welcome to InstallShield Wizard for Leica Viva amp GR USB drivers window appears CS Ensure that all Leica Viva devices are disconnected from your PC before you continue Next gt The Ready to Install the Program window appears Install The drivers will be installed on y
54. rn CS field controller over to gain access to the battery compartment Push the slide fastener in the direction of the arrow with the open lock symbol Open the battery compartment Pull the battery from the battery compartment Place the battery into the battery compartment with the Leica logo facing to the top Zeno 10 Zeno 15 Operation 51 Zeno 10 Zeno 15 Operation 52 Step Description 5 Close the battery compartment by pushing the slide fastener in the direc tion of the arrow with the close lock symbol Insert and remove the battery on the GGO2 plus step by step Description Turn GGO2 plus over to gain access to the battery compartment Open the battery compartment by pushing the slide fastener in the direc tion of the arrow with the open lock symbol Pull out the battery housing The battery is attached to the housing Step Description 4 Hold the battery housing and pull the battery from the battery housing 5 A polarity of the battery is displayed inside the battery housing This is a visual aid to assist in placing the battery correctly 6 Place the battery onto the battery housing ensuring that the contacts are facing outward Click the battery into position 7 Close the battery compartment by pushing the slide fastener in the direc tion of the arrow with the close lock symbol
55. s only available as Online Help Refer to the following resources for all Zeno 10 Zeno 15 documentation soft ware e the Leica Zeno GIS DVD e https myworld leica geosystems com myWorld Leica Geosystems https myworld leica geosystems com offers a wide range of services information and training material With direct access to myWorld you are able to access all relevant services whenever it is convenient for you 24 hours a day 7 days per week This increases your effi ciency and keeps you and your equipment instantly updated with the latest informa tion from Leica Geosystems Zeno 10 Zeno 15 Introduction Zeno 10 Zeno 15 Introduction Service Description myProducts Simply add all Leica Geosystems products that you and your company own View detailed information on your products buy additional options or Customer Care Packages CCPs update your products with the latest software and keep up to date with the latest documentation myService View the service history of your products in Leica Geosystems Service Centers and detailed information on the services performed on your products For your products that are currently in Leica Geosystems Service Centers view the current service status and the expected end date of service mySupport Create new support requests for your products that will be answered by your local Leica Geosystems Support Team View the complete his
56. side the Connection Settings window of Active Sync For PCs with Windows Vista or Windows 7 operating system 14 Windows Mobile Device Center starts up automatically If does not start automatically start Windows Mobile Device Center Zeno 10 Zeno 15 Operation 45 Zeno 10 Zeno 15 Operation 46 Connect to PC via USB cable step by step Step Description 1 Start the PC 2 Plug the GEV234 cable into CS field controller Cg For CS field controllers with DSUB9 connector the GEV223 cable has to be used 3 Turn the CS field controller on 4 Plug the GEV234 cable into the USB port of the PC For PCs with Windows XP operating system Cg ActiveSync starts up automatically If does not start automatically start ActiveSync If not already installed run the ActiveSync instal lation program Step Description Allow USB connections inside the Connection Settings window of Active Sync Click Explore in ActiveySync CS The folders on the CS field controller are displayed under Mobile Devices The folders of the data storage device can be found in StorageCard For PCs with Windows Vista or Windows 7 operating system Cg Windows Mobile Device Center starts up automatically If does not start automatically start Windows Mobile Device Center Zeno 10 Zeno 15 Operation 47 Zeno 10 Zeno 15 Operation 48
57. systems AG declares that the product CS15 is in compliance tions with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity can be consulted at http www leica geosystems com ce Class 2 equipment according European Directive 1999 5 EC R amp TTE for which following EEA Member States apply restrictions on the placing on the market or on the putting into service or require authorisation for use e France e Italy e Norway if used in the geographical area within a radius of 20km from the centre of Ny Alesund e The conformity for countries with other national regulations not covered by the FCC part 15 or European directive 1999 5 EC has to be approved prior to use and operation Zeno 10 Zeno 15 Technical Data 113 Zeno 10 Zeno 15 Technical Data Frequency band Output power Type Frequency band MHz CS15 Bluetooth 2402 2480 CS15 3 5G GSM UMTS UMTS HSDPA WCDMA FDD 850 1900 2100 Quad Band EGSM 850 900 1800 1900 GPRS multi slot class 12 EDGE multi slot class 12 CS15 WLAN 2400 2484 Type Output power mW CS15 Bluetooth 2 5 CS15 3 5G GSM UMTS EGSM850 900 2 CS15 3 5G GSM UMTS GSM1800 1900 1 CS15 3 5G GSM UMTS UMTS2100 0 25 CS15 3 5G GSM UMTS EDGE850 900 0 5 CS15 3 5G GSM UMTS EDGE1800 1900 0 4 CS15 WLAN 802 11b 50 CS15 WLAN 802 11g 6 Mbit s 36 Mbit s 50 CS15 W
58. tenna Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Zeno 10 Zeno 15 Safety Directions 83 Zeno 10 Zeno 15 Safety Directions 84 A Warning Changes or modifications not expressly approved by Leica Geosystems for compli ance could void the user s authority to operate the equipment Labelling CS10 Equi No Power Leica Geosystems AG CH 9435 Hoerbrugg Manufactured Made in Switzerland C Ena FCC ID Bluetooth QPL IC This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation c e Labelling CS15 3 B es C Leica Geosystems AG 0681 CH 9435 Heerbrugg ECO ID d Manufactured Bluetooth QPL Made in Switzerland Ie This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause Wiesen Qs e Labelling GSO5 GS06 Type Equi No Leica Geosystems AG
59. tools for example screwdriver unless this is permitted for certain functions Modification or conversion of the product Use after misappropriation Use of products with recognisable damages or defects Use with accessories from other manufacturers without the prior explicit approval of Leica Geosystems Inadequate safeguards at the working site for example when measuring on roads Controlling of machines moving objects or similar monitoring application without additional control and safety installations Adverse use can lead to injury malfunction and damage It is the task of the person responsible for the equipment to inform the user about hazards and how to counteract them The product is not to be operated until the user has been instructed on how to work with it Zeno 10 Zeno 15 Safety Directions 71 Zeno 10 Zeno 15 Safety Directions 72 5 3 Environment A Danger LE Environment Limits of Use Suitable for use in an atmosphere appropriate for permanent human habitation not suitable for use in aggressive or explosive environments Local safety authorities and safety experts must be contacted before working in hazardous areas or close to electrical installations or similar situations by the person in charge of the product The following advice is only valid for battery charger power adapter and car adapter Suitable for use in dry environments only and not under adverse conditions
60. tory of your Support and view detailed information on each request in case you want to refer to previous support requests myTraining Enhance your product knowledge with the Leica Geosystems Campus Information Knowledge Training Study the latest online training material or download training material on your products Keep up to date with the latest News on your products and register for Seminars or Courses in your country Table of Contents In this manual Chapter Page 1 Description of the System 11 l 1 Overview 11 1 2 Terminology 12 1 3 System Concept l 1 3 1 Software Concept l4 1 3 2 Power Concept 18 1 3 3 Data Storage Concept 19 1 4 CS Components 21 1 4 1 CS10 21 1 4 2 CS15 23 1 5 Docking Station Components 25 2 User Interface 26 2 1 Keyboard 26 2 2 Operating Principles 32 Zeno 10 Zeno 15 Table of Contents 7 Zeno 10 Zeno 15 Table of Contents 3 Operation 33 3 1 Equipment Setup 33 3 1 1 Fixing the Display Foil to the CS 33 3 1 2 Fixing a Hand Strap to the CS 35 3 1 3 Fixing the Slot Cover to the CS 36 3 1 4 Inserting and Removing a SIM Card 37 3 1 5 Setting up as Handheld GNSS 39 3 1 6 Setting up the Docking Station 41 3 1 7 Connecting to a Personal Computer 42 3 2 Power Functions 48 3 3 Batteries 50 3 3 1 Operating Principles 50 3 3 2 Changing the Battery 51 3 3 3 Charging the Battery 54 3 4 Working with the Memory Device 56 3 5 LED Indicators on CS10 CS15 60
61. using the supplied stylus Operation Description o select an item Tap on the item To start the edit mode in editable fields Tap on the editable field o highlight an item or parts of it for editing Drag the supplied stylus from the left to the right To accept data entered into an editable field and exit the edit mode Tap on the screen outside of the editable field To open a context sensitive menu Tap on the item and hold for 2 s 3 Operation 3 1 Equipment Setup 3 1 1 Fixing the Display Foil to the CS Fixing the display foil to the CS step by step Description Ensure that the display of the CS is free of dust and grease The non reflecting display foil has a silver coloured sticker to peel away the carrier foil from the actual display foil Touch the silver coloured sticker with two fingers and pull it slowly upwards The carrier foil is peeling away CS Do not peel the carrier foil more than 2 cm 3 cm away Zeno 10 Zeno 15 Operation 33 Zeno 10 Zeno 15 Operation 34 Step Description 2 Fix the laid open adhesive underside of the display foil at the display border CS Pay attention that the display foil is not fixed between display and display frame Peel away the carrier foil bit by bit and smooth it out slowly onto the display Potential air bubbles between display and display foil
62. wer is low The remaining time for which enough power is available depends on the use of wireless modules the temperature and the age of the battery The battery is being charged red power is very low The battery should be changed flashing red power is very low The battery is being charged Zeno 10 Zeno 15 Operation 61 Zeno 10 Zeno 15 Operation 62 3 6 LED Indicators on GGO2 plus LED indicators Description The GGO2 plus instrument has Light Emitting Diode indicators They indicate the basic instrument status Diagram a Tracking LED TRK b BT Bluetooth LED BT c Power LED PWR Description of the LEDs IF the is THEN TRKLED off No satellites are tracked flashing green Less than four satellites are tracked a position is not yet available green Enough satellites are tracked to compute a position red GGO2 plus instrument is initialising BT LED green Bluetooth is in data mode and ready for connecting purple Bluetooth is connecting blue Bluetooth has connected flashing blue Data is being transferred PWR LED off Power is off green Power is okay flashing green Power is low The remaining time for which enough power is available depends on the type of survey the temperature and the age of the battery Zeno 10 Zeno 15 Operation 63 Zeno 10 Zeno 15 Operation 64 3 7 Overview Taking a

Download Pdf Manuals

image

Related Search

Related Contents

C L C L - DuPont Canada  Mistral 6000 User's Manual  Front Turn Signal Relocation Kit Instruction Sheet - Harley  1モーター  clonador borrador autonomo de unidades memoria flash usb 1:5    Audiovox 128-8146 Automobile Alarm User Manual  1999 Polaris Service Manual  EDS Provider Electronic Solutions - Connecticut Medical Assistance  Triarch 75272-15 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file