1. Terminal wire connector function OPEN Yellow Open door button NO 12V Red 12V power input Relay output NO COM Purple Relay output COM NC Orange Relay output NC Common powers connects diagram LO van Open door button Common 12V 3A O Zz Power on the Off power the locks keep opening Special power supply Red Black Blue Purple Orange 12V special power supply Power on the locks keep openin Note We adviseyou use specialadaptor itwi Open door button Yellow Off power the g locks keep opening OPEN 12V GND NO COM NC GND COM make yoursystem work morestable Power on When all connections are finished youcan power on This time the buzzer will givea long ring and red ledflashing The machinewill enter regular workstatus Operation guide 1 Manager mode usingInfrared remote control keypad 1 1 Enter programming mode Press manager password Manager password 9999 factory default setting 1 2 Changing manager code In programming mode Press 0 newpassword code Repeat new password code The manager code must be 4digit number 2 Add anddelete Users There are 3 ways to add and delete user 1 by keypadj 2 by User IDj 3 by Manage
2. Fingerprint 2 1By keypad the most convenient way Add User manager password 7 input fingerprint twice to add more thanone user justinput finger continuously Delete User managerpassword 8 inputfingerprint once to delete more thanone user justinput finger continuously Note When add fingerprint please put the Fingerprintwhich you will addon the sensor twice during which the light shines red then turngreen means the Fingerprintis added successfully when delete users justinput fingerprint once 2 2 By User ID To addone user Managerpassword 1 IDnumber Input userFingerprint twice User ID number canbe any digit between3 120 but onelD number to oneuser Toadd users continuously Manager password 1 3 1 User Fingerprint 4 2 user fingerprint N N user fingerprint To delete one user Manager password 2 ID number To deleteusers continuously Manager password 2 Dnumber ID number ID number 2 3 By Manager fingerprints In programming mode Press 1 1
3. input fingerprint twice 2 input another ingerprint twice ID number 1 Manager add fingerprint ID number 2 Manager delete fingerprint The first Fingerprint Manager add Fingerprint itis to add theusers The second Fingerprint Managerdelete Fingerprint it isto delete users To addone user Press Manager addFingerprint Input User Fingerprint twice RepeatManager add Fingerprint Note input the user s fingerprint twice during which the light shines red then turn green means the Fingerprint is added successfully P
4. Manual Introduction F007 use the precise electron circuitand good productive technology whichis the metal structure fingerprint amp access machine This machine usesthe most advanced fingerprintidentification technology very safety Which is the most ideal choose It is widely used in business affairs organization office factory housing district etc This product s programmingis done by the infrared remote control keypad or fingerprint manager This product maximum can store 120 fingerprints There are 2 fingerprint managers and eachfingerprint has one ID code Specifications Sleeping function When this machinein stay status it will autoenter sleep status This can reduce power dissipation and prolongthe machine s uselife Manager infrared remotecontrol keypad Users use infraredremote control keypad when enter the programming mode they can operate as follow Changing manager code Add fingerprints Delete fingerprints Delete all fingerprints release alarm Setting open door time Setting release alarm Manager fingerprint operation function ID number 1 Manager add fingerprint can t opendoor number 1is used add users number2 is used deletedusers D number 2 Manager delete fingerprint D number 3 120 users fingerprint User fingerprint operationfunction D number 3 120 users fingerprint are used open door Open door button operationfunction This button isused to openthe door Parma setting function Open door
5. To addusers continuously Resetting to factory default setting Press manager s add fingerprint 1 user fingerprint 2 user fingerprint 3 user fingerprint N User Fingerprint Manager s add fingerprint When add user the fingerprintsID number willauto add from3 120 To deleteusers Press manager s delete fingerprint 1 user fingerprint 2 user fingerprint 3 user Turn off thepower pressthe reset key SW1 on the PCB keep holding itand re power the device the F007 will give three short beeps means resetto factory setting successfully then move more your finger offfrom the resetkey It is torevert all settings to the factory default setting butthe users dataenroled is safe fingerprint N User Fingerprint Manager s delete fingerprint Sounds and lightstatus 3 Delete all fingerprints Press managerpassword 20000 Operation Status Red led Green led Note This will deleteall fingerprints including Manager Fingerprint before this operationyou need make Resetting Brigh
6. t Bright Goes out Consecutive short ring sure the data isunusetul Power on Slow flashing Goes out a Short ring 4 Setti d ti Sleeping status Slow flashing Goes out Goes out F 0 0 etting open door time 7 Press g TANE password AXX F Stay status Slow flashing Goes out Quickly flashing 7 1 2 Voided ki ae Short ring Note Open door timeis the lockkeeps time XX0 10s default setting 5s ticles f Fingerprint Access controller Enter programme status Bright Goes out Goes out Short ring 5 Exit programming mode Programme status Bright Goes out When the operationis over you can press to exit from programming mode If no press Input fingerprint instruct but over 1 minute it will exit from programming mode automatically Input fingerprint success Goes out Bright Input fingerprint fail Three short ring 6 Manager releasealarm Exit programming status Long ring When this machine isin stay status ifit was be opened the buzzer will soundconsecutive Open door status Goes out Bright Goes out Long ring long ring And it i a f alarming Quickly flashing Goes out Quickly flashing Consecutive long ring Will be keep on1 minute While itin the alarm statusyou can use eitherof the follow ways Neti i k F007 Simplified Instruction release alarm A a a Use Infrared remote control keypad input alarm release password Technical Specification Function description Choose from the relevant functions below and input
7. the release password isthe same with managerpassword 7 b Use manager fingerprint press mangers fingerprint either manager add fingerprint or Supply Voltage 12VDC 10 User fingerprint quantity 118 i 9999 manager delete fingerprint isok Sleeping Current lt 20mA Resolution 450 DPI Enter the programmingmode then you cando the programming Stay Current SOMA Fingerprint input time has 9999 is the default factory master code a e Door Relay Identification time lt 2S change the master code 0 newcode repeat thenew code Ta swe Tamper suiten f Temperature 20C 55C FAR lt 0 0001 code 4 digit O O PCB connect diagram Humidity 20 RH 95 RH FRR lt 0 01 Add user 7 Fingerprint repeat Fingerprint Le Swi Reset switch Memory capacity 120 Dimensions 115mmx 70mmx35mm can add Fingerprints continuously Manager quantity 2 weight 500g 8 Fingerprint Delete user can delete Fingerprints continuously aas Package Listing Exit from theprogramming mode A a E e E n Descriptions Model no Quantity Remark How do release thedoor O O 7 o a gt Fingerprint amp Door Access machine F007 1 O gt Fingerprint User Put the Fingeron the fingerprintsensor for 1second 202 Z N W anfrated remote control keypad O o User Manual F007 Wiring C amp gle Hamess ei Se Security Screws O3mmxX7 5mm Used for front case and back case O O Screw driver Self tapping screws 4mmx25mm 4 Used for fixing J Pastern stopper 6mmx25mm 4 Used for fixing User
8. time 0 10s default setting 5s User can use infrared remote control keypad setting Relay out NC and COM When power off the lock isopened NO and COM When power on the lock isopened Manager release alarm When this machine isin stay status ifit was opened the buzzer will sound consecutive long ring And it willbe kept for1 minute Important information If holes are tobe drilled before mounting onto a wall checkfor hidden cables and orpipes before drilling Use safety goggles whendrilling or hammering incable clips Every effort has beenmade to provide accurateinformation however slight variationscan occur Wealso reserve the right tomake changed for productimprovement at any time A Intramural interface circuit Electric lock interface NO This machine use relay which makes sure this part A C NO gt hasn t any connect When the lock is opened the relay O closed The relay put out circuit is2A Relay jiss Electric lock interface Install wiring and fixation Drill 4 holeson the wall Thread the cablethrough cable hole Wiring When wiring completed attach the rear plate to the wall firmly with at least three flat head screws Plug the cable harness Attach thefront cover to therear plate EONS mo Note Please don t power onbefore you connect finish Install diagram a eed ox 71 on Infrared Sensor a oJ e oe Fingerprint Sensor