Home
        FSTL1000 Operators Manual.indd
         Contents
1.       FSTL1 000    Endura Tower Light  Operator s Manual                                                                DO NOT operate this equipment until you have  read and understood all the enclosed Operator s  Manual     READ ALL the sections in this manual PRIOR to  attempting to service  maintain or operate this  equipment        Copyright Uniquip Canada 2004  All rights reserved     A www uniquip ca    Endura Warranty Statement    Uniquip Canada Inc  guarantees all Uniquip Endura Tower Lights to be free  from any manufacturer s defects in material and workmanship for a period of one  1   year from the date of purchase   This warranty is exclusive of any normal wear and  tear and or consumable parts  such as the lamp  fuse  and wheels  All normal wear  and tear and or consumable parts are protected from manufacturer s defects in  material and workmanship for a period of thirty  30  days from the date of  purchase     endura Warranty Summary  1  Uniquip Endura Tower Light Unit 1 year parts and labour    2  Uniquip Endura normal wear and 30 days parts and labour  tear parts or consumable parts    To make a warranty claim within this time period  please contact the Service  Manager at Uniquip Canada Inc   1 800 332 4012  who will advise the validity and  claim procedure  Once the claim has been accepted by Uniquip Canada  the unit  and parts should be shipped to Uniquip Canada or the specified Authorized Service  Centre at the customer s expense  Be sure to securely pack 
2.  6 7 8 9  10  Soc i a A E E N EE E E ia  Setting up the FSTLT000 oo  eesssssscsssssssssssssssesssssssssesssssseesssseeesssneees 12  13  Pre Operation Procedures       ssssssssssssssssssssssssssscssssssssessssseeesssssseesssssseeesssvees 14  Operation Procedures      ssccesssssssesssssssssssssssssssesssssseessssseseesssssseeessssvsseessnvees 15    A    A    DO NOT operate this equipment until you have  read and understood all the enclosed Operator s  Manual     READ ALL the sections in this manual PRIOR to  attempting to service  maintain or operate this  equipment        Copyright Uniquip Canada 2004  All rights reserved       www uniquip ca    Pre Operation Notes    Thank you for your purchase of the Uniquip Endura FSTL1000 Portable  Tower Light  This tower light has been designed and manufactured to our  highest quality demands for durability and performance        Uniquip Canada Inc  is committed to offering durable products and  quality after market service  The FSTL1000 Portable Tower Light is warranted  to be free from manufacturer s defects in material and workmanship for a  period of one  1  year from the date of shipping as declared on the invoice  from Uniquip Canada  This warranty will be void if the light tower has not  been operated and maintained in the manner prescribed in this Operator s  Manual     In order for the tower light to perform at its optimum capabilities  the  operator of the unit must read this manual thoroughly before using this  unit  This Opera
3.  is rated for    20  NEVER LOOK DIRECTLY INTO LIGHTED LAMP    21  NEVER OPERATE THE FIXTURE WITHOUT SAFETY LENS  If safety  lens is broken  replace lens prior to operating fixture    22  Keep fixture away from children    23  DANGER  HIGH VOLTAGE     24  Provide adequate protection and guarding of all movable parts     SAVE THESE INSTRUCTIONS        GO    NOUA    3 www uniquip ca       Guide to Machine Overview Parts List    Regular maintenance and parts replacement are important steps to extending  the life of your equipment and enjoying its optimum performance  When performing  any maintenance or repair procedures  always check with local authorities  for by laws and guidelines governing your jurisdiction     This guide aims to serve as a representational guide to the FSTL1000  Any  other uses or application beyond the scope of this document are strictly  prohibited  While every attempt has been made to maintain its accuracy  Uniquip  Canada Inc  reserves the right to update and modify the equipment without prior  notification  Prior to undertaking to perform any maintenance or repair procedures   please contact our Technical Support Hotline for clarification and to acquire  appropriate parts     To order spare parts  please provide the following information   1  Machine Make  2  Model Number  3  Machine Serial Number  4  Quantity Required of Each Part  5  Part Numbers  6  Part Descriptions     All Endura parts are guaranteed by a thirty  30  day warranty against any  manuf
4. 33  FSTL1000 06   Bracket Mount U Bracket       FSTL1000 38     Bracket Pin       FSTL1000 39       O Pin FSTL1000 35     Shock Absorber   sold individually                     A  j    i  t    is       FSTL1000 36  Washer             FSTL1000 APK     Mast Adjustment Pin for    FSTL1000 ONLY                                                                                 FSTL1000 APK Y   Mast Adjustment Pin for  FSTL1000Y ONLY    FSTL1000 07   Mast for FSTL1000 ONLY    FSTL1000 07 Y   Mast for FSTL1000Y ONLY    
5. USE  WAIT FOR AT LEAST 10  MINUTES AFTER SHUT DOWN TO BE IN CONTACT WITH LAMP      Make certain that the power source conforms to the requirements of your  equipment  NEVER ALTER THE PLUG      DO NOT plug pump into any NON GROUNDBED electrical outlet      DO NOT attempt to remove ground stem on plug      USE ONLY on GFCI protected circuits      MAKE SURE OPERATOR  CABLE  PLUG AND SOCKET ARE ALL  DRY AND CLEAN  LIQUIDS AND ELECTRICITY DO NOT MIX   CHEMICALS AND ELECTRICITY DO NOT MIX    8  DO NOT operate where water may accumulate around base    9  DO NOT submerse any portion of the FSTL TOOQMH Tower Light in liquid    10  Keep light AT LEAST 16  FT AWAY from pools and spas    11  Keep light away from any flammable materials    12  DO NOT perform any repairs or maintenance procedures on tower light  unless it has been disconnected from any power source    13  Use only Endura brand name parts    14  ALL frayed and or otherwise damaged cords and components MUST  be replaced before further use    15  When using in windy and or other difficult weather conditions  set tower  light up such that the wind is at the back of the fixture and apply the  brake  Support with sand bags if necessary    16  If light is extended higher than 6  ft  anchor base to ground    17  Always ensure that tires are filled up at proper tire pressure    18  Always set brake on tower light for transport or when tower light will  be left unattended    19  Never use any light bulbs larger than what the fixture
6. able separately     FSTL1000 39 O Pin  available separately   FSTL1000 40  FSTL1000 41 Knob  available separately     FSTL1 000 49    FSTL1000 08  Outer Axle       Parts that are components of the following kits are not available separately  unless otherwise stated     17 www uniquip ca          Prior to setting up the FSTL1000  Tower Light  check that the  following items are enclosed     item   Quantity   Check if enclosed  1000 W Metal Halide lamp   1       Yes     No  os Kh Yes Ne  Metal Ring ff tes No  Rubber Ring     I   Yes N  rege tad Wakes  1   Ye No    Uniquip Endura FSTL1000     Tower Light Operator s Manual  If any of these items are missing  please contact 1 800 332 4012 and ask  for the Service Manager at Uniquip Canada Inc  at once           DO NOT ATTEMPT ASSEMBLY OR OPERATION WITHOUT ANY OF  THESE LISTED PARTS     Technical Support Hotline    Ontario  Quebec  Western Canada  and USA and Eastern Canada  T  1 888 332 4012 T   1 800 332 4012  F   1 866 567 0956 F   1 866 825 2221    email your technical questions and comments to   service uniquip ca    visit our website   www uniguip ca       www uniquip ca       1  Place Ballast Assembly on floor     Tilt it such that the base of the assembly   faces the operator  Remove and put aside  washers from metal feet and brake   Keep rubber supports on metal feet      Figure 1    2  Flip cart over ballast box  and line up ballast support  bars to metal feet  Tighten  ballast to cart with washers  from metal feet and br
7. acturer s defects in workmanship and material  Consult page A in the  Operator s Manual for further details on our Warranty Policy     Technical Support Hotline    Ontario  Quebec    Western Canada  and USA and Eastern Canada  T   1 888 332 4012 T   1 800 332 4012  F   1 866 567 0956 F   1 866 825 2221    email your technical questions and comments to   service uniquip ca    visit our website   www uniquip ca       www uniquip ca Ar    EE                                                                                            5 www uniquip ca www  uniquip ca 6       Key Components Overview    A  Reflector and Lens Assembly   17  15 16     6   FSTLIO00 06   UBracket   8  FSTL1000 08  Cort o     9   FSTLIOOO BRAKE  Brake Kit    1  FSTL1000 1 1 Ballast  Not shown  See     Key Components Overview     for details     FSTLI000 12   Ballast Box    FSTL1000 13 Ballast Lid  FSTL1000 14    13  Many of the parts making up each section of the FSTL1000 Tower Light have A E    been packaged into kits for your convenience  Refer to the  Key Components r   31  Overview  section for further details     If you have any questions concerning the maintenance and operations of this a  w  unit  please do not hesitate to contact Uniquip Canada                                                                                                                                                                                        DO NOT attempt servicing or performing any maintenance A Y  procedures outl
8. ake      Figure 2    ma    ig       4  Place rubber ring on fixture   Make sure that the ring is  correctly aligned to markers  on fixture   Figure 4        6  Place reflector on flat surface with  the fixture side up  Remove U Bracket  kit  2 large knobs  1 smaller knob  2  O pins and 2 washers from package   Line up U Bracket to fixture such that  the holes on each side of the bracket  line up with holed on the sides of the  fixture  Attach bracket to fixture with    2 large knobs and washers    Figure 6     3        10    SE OEE EO  e  Setting up the FSTL1000       Figure 1     Turn cart and  ballast back to its  proper position   Undo mast lock on  mast support   Insert mast into  mast support and  tighten mast lock    to hold the mast in place    Figure 3        Figure 3       Line up reflector to holes on rubber    ring and the markers on the fixture   Place metal ring on top of the  reflector  again making sure that its  holes are lined up with the reflector  and fixture  Check that the security  chain hangs on the bottom of the  reflector  Bolt down assembly to  fixture with 4 bolts and nce   Figure 5     Figure 5        Figure 6     13 www uniquip ca       Setting up the FSTL1000 cont d    8  Unpack Lens Kit and attach  security chain on reflector to  lens  Let lens hang from  reflector and screw in  1000 W metal halide lamp   Figure 7  into fixture  Clip lens onto   fixture   Figure 8          7  Slide bracket and fixture onto  mast  Insert 3 pins into holes    to a
9. at with  second mast mast section     7  To lower the telecopic mast  pull on safety lock while grasping raised mast  with one hand and raising it slightly  SLOWLY lower mast  DO NOT  DROP MAST     SAVE THESE INSTRUCTIONS      www uniquip ca 16       17 www  uniquip ca       Technical Support Hotline    Ontario  Quebec    Western Canada  and USA and Eastern Canada  T   1 888 332 4012 T   1 800 332 4012  F   1 866 567 0956 F   1 866 825 2221    email your technical questions and comments to   service uniquip ca    visit our website   Www uniquip ca       Copyright Uniquip Canada 2004  All rights reserved     FSTL1000 08  Cart Wheel Base       FSTL1000 41  Cart Wheel Base          FSTL1000 10     Wheel  with bolt and washer  FSTL1000 BRAKE  Brake Kit    FSTL1000 BALLAST     Ballast Assembly FSTL1000 14     4m Electrical Connection Cord                      FSTL1 0002    ENDURA    Sh          FSTL1000 58   Power Cord       FSTL1000 CAPACITOR      FSTL1000 31   Capacitor Electrical Switch  includes boot    and ON OFF plate     FSTL1000 01  Fizture Casing       FSTL1000 01A   Electrical Components  for Fixture          FSTL1000 23  Ceramic Element    FSTL1000 02  Reflector          FSTL1000 02A   Spacer Kit for Reflector       FSTL1000 03   Lens Clip  sold individually          FSTL1000 LENS   Complete Lens Kit  Includes glass  lens  silicone ring  amp  aluminum frame    FSTL1000 27   Safety Chain  amp  Clip    FSTL1000 41   Knobs       FSTL1000 18   Security Cable       FSTL1000 
10. g the light on proposed jobsite  perform the following  environmental checks    a  Check that available electrical outlets conform to local codes    b  Run light only on GFCI protected circuits    c  If the proposed jobsite is on an incline  counterbalance light with  weights to ensure stability   Keep the light at least 16  feet away from any pools or spas   Keep the lamp away from any flammable materials     oo    If any of the above check fail  please DO NOT operate the light     15 www uniquip ca    Operation Procedures    1  Plug cord into any 15 amps or greater 120 volt 60 Hz power source        2  Turn tower light on  As the light bulb is being energized  there will be a  slight humming noise issuing from the ballast     3  Should there be any interruption in the power to the tower light  it will  require approximately 20 minutes to re power the light bulb  Always  switch light OFF before re powering the unit     4  To adjust the fixture bracket and light head  pull pin  raise bracket to the  vertical position and slide pin back in place     5  When adjusting the light fixture  always make sure that the fixture is COOL  before adjusting  Aim the fixture approximately 15   above desired level   Tighten knobs lightly to hold fixture in place  then pull fixture down to  desired level  Completely tighten knobs to secure fixture     6  To raise the telescopic mast  grasp upper mast firmly and raise the post  until the safety lock is engaged  To further extend the mast  repe
11. ined in this manual unless technician is qualified 28        gt     and clear on the task s requirements  20 11 a    30       7       Key Components Overview cont d    A  Reflector and Lens Assembly    www  uniquip ca       B  Ballast Assembly    FSTL1000 29  FSTL1000 30    FSTL1000 32 Fuse  not shown        www uniquip ca       C  U Bracket Kit    33 34  l  LN a    a3   iP                                           E  Brake Assembly 48    _       so            Tea                             cw                Key Components Overview cont d    D  Mast                                                 9    www uniquip ca       Key Components Overview cont d    C  U Bracket Kit  FSTL1000 BRACKET     FSTL1000 06  FSTL1000 33    STL1000 34      2       es     34 F     35   FSTL1000 35    36  F  a   S         STL1000 36  40  FSTLIO00 40_  Washer  41  FSTL1000 41__  Knob  available separately          33  34  3D  36  Oo   38  37  40  A     D  Mast Kit  FSTL1000 MAST     FSTL1000 07        available separately     Brake Kit  FSTL1000 BRAKE     FSTL1000 46  Right Brake Arm  FSTL1000 47 Left Brake Arm       FSTL1000 48 Brake Handle  FSTL1000 49  FSTL1000 50       www  uniquip ca    Key Components Overview cont d       F  Cart Kit  FSTL1000 CART       8   FSTLIOO0 08  Cot S    10          FSTL1000 MAST   Mast Kit  FSTL1000 07     available separately   Bot S    Washer     available separately   Fuse  not shown     available separately   FSTL1000 34   Bol    FSTL1000 38 Bracket Pin   avail
12. the unit and parts in a  strong container  Damage in transit is not covered by this warranty    All approved repairs under this warranty will be returned by Uniquip Canada free of  charge           Warranties expressed in this document are void if repairs are attempted by  anyone other than an Authorized Service Centre or Uniquip Canada or if the unit has  been modified from original factory design in any way  This warranty is expressly  conditional upon the customer s compliance with all precautions and instructions  contained in this manual and excludes any claims made as a result of abuse  neglect   accident  normal wear and tear and misuse  This warranty is non   transferable     Uniquip Canada Inc  s liability under warranty is limited to repair of the  product and or replacement of parts and is given to the purchaser in lieu of all other  remedies including incidental and consequential charges  There are no expressed  warranties other than those specified herein     www  uniquip ca B    Endura Warranty Registration    Congratulations for choosing an Endura product to meet all your tough  jobsite needs  Please file your original bill of purchase for this unit in a safe place   For warranty service of your Endura product  you will need to provide a copy of this  document to confirm your warranty status        Product registration is a key step toward enjoying your new Endura  product  While registration is not necessary to enjoy our manufacturer s warranty   there are man
13. tor s Manual contains important product operation  procedures  and safety precautions  SAVE THIS MANUAL  Please keep  this manual nearby when operating the tower light as a reference should any  questions arise     This tower light is a high voltage electrical device  DO NOT start  this unit unless it is clear of water or water filled areas  DO NOT  use this tower light with non grounded sockets  Use this light  only with GFCI protected circuits  This product is designed for  normal outdoor use     All jobsites are different  Please ensure that when installing this tower  light in a jobsite  proper precautions have been taken to avoid any accidents   and to reduce the risk of fire  electric shock or personal injury     Every care and effort has been made to ascertain the accuracy and  completeness of procedures described in this document to ensure your  enjoyment and satisfaction  If you have any questions or concerns  please  contact the Service Department at Uniquip Canada at 1 800 332 4012     Technical Support Hotline    Ontario  Quebec  Western Canada  and USA and Eastern Canada  T  1 888 2 T  1 8     332 401  F   1 866 567 0956    00 332 4012  F   1 866 825 2221    email your technical questions and comments to   service uniquip ca    visit our website   www uniqguip ca       www uniquip ca 2    Safety Precautions    1  READ AND UNDERSTAND OPERATOR S MANUAL PRIOR TO USE  OF TOWER LIGHT    2  THE LIGHTED LAMP IS HOT  DO NOT TOUCH LIGHT FIXTURE   REFLECTOR OR LENS DURING 
14. ttach fixture to mast    Figure 7     9  Unwind security cable and  hook it onto lens clips   Secure cable with spring     Figure 9     Figure 8        Figure 9     10  Move Tower Light to desired area with level surface   Set brake for extra stability     Technical Support Hotline    Ontario  Quebec  Western Canada  and USA and Eastern Canada  T  1 888 332 4012 T   1 800 332 4012  F   1 866 567 0956 F   1 866 825 2221    email your technical questions and comments to   service uniquip ca    visit our website   www uniquip ca       www uniquip ca 14    Pre Operation Procedures    Before using the Endura FSTL1000 Tower Light  please perform  the following procedures for the personal and property safety of the operator  and jobsite        1  Before operating the light ensure that it is structurally and mechani   cally safe by checking the following    a  Inspect that all the sections of the Tower Light are properly  installed as per the guidelines in the section  Setting up the  FSTL1000     i  Is the mast securely bolted into the mast support   ii  Is the floor brake being used for further stability and to  hold the light in position   iii  Are the wheels properly inflated   iv  Is the lens secured clipped and chained to the reflector   v  Is the cable worn  fouled or in any other conditions that  would prevent the light from safe operation     CONTINUED USE OF FRAYED OR DAMAGED  CABLE CAN RESULT IN PROPERTY DAMAGE    AND OR SEVERELY INJURING THE OPERATOR        2  Before usin
15. y benefits to participating in this program  Registration helps to  facilitate warranty service  and notify you of any updates  changes  and service  advisories on your product  Complete this Warranty Registration Card and fax it to    1 866 825 2221 or mail it to the address on the back of this card   Warranty Registration Information  A  Ownership Information          Owner s Name   Company Name     Company Address        B  Machine Information  Machine Make    Machine Model      Machine Serial      Date of Purchase    C  Product Information Update    Can we contact you with any Yes No  product related news                 Who should we contact   Contact Telephone   Contact Fax    Contact E Mail     What is the preferred contact method                    Laval QC  HZL 5B9         m   sS  S Oo  5   lt   e Z  5 2   N  cD  5 oF  oN      gt     ATTN  SERVICE DEPARTMENT       JENDUZA        FSTL1 000    Endura Tower Light  Operator s Manual    Pre Operation Note       sssssssssssseesesseessssseeesnrsnsennnnnsttrornrnsnnnnnnnetonorrnsnnnnnnnrrnrnrns l  Sofety Precautions        ssssssssssssssssssssssscsssssvsssescsssssssssesssssssssseessssssvseeseessssvesses 2  Guide to Machine Overview     ssccccssssssessssssssessssssssssssssssssssssseseessssseeessnseeeees 3  Machine Overview      sssssesssssssssesssssssssssssssseesssssssssessssssessssssssessssseseeesssveeeesen 4  OTS S a E E A deans aehanieeeton cons   Key Components Overview     ssessesssecssesssesssssssnesssesssnessseennessen
    
Download Pdf Manuals
 
 
    