        Prairie Fire Owners Manual PFG060 Revised Aug 12, 2007 FINAL
         Contents
1.    diameter air intake for bringing com   bustion air to the stove   After obtaining the necessary parts of Model VP L Vent  that will be needed to convert the system to L Vent   attach them to the pellet stove outlet   Pesietration  Trim Plate Wall Spacer                    Termination Decorative  Adapter   Cone Cap or    Non Combustible Exit C  Pa Flexible Pipe For Ain ee  Stove Intake Connection  Pellet Stove  Adapter  Adapter Air    Place Silicone    Sealant Here On All  3 Model VPL Vent  Increaser     Ftc  Co  Through the Wall Installation  Fig          Horizontal Installation  Fig  3    Appendix A    Minimum Extension    T T  Through Wall       Vertical Installation  Fig  5    Place a bead of high temperature silicone sealant around  the perimeter of interior liner  at the end of the outlet   of the section of Model VP that will be connected to the  Pellet Stove Adapter   Note  All Model VP components  should be sealed in this manner   See Fig       Connect the pellet pipe to the Model DT Pellet Stove  Adapter by pushing the inlet end of the adapter down  over the outlet of the pellet pipe until fully seated   Screw the adapter to the pellet pipe using the three 1 4      8 sheet metal screws provided  Connect other sections  of Model DT Direct Vent as needed following Model  DT main instructions     Connecting to Stove Air Intake   Connection of the stove air intake to the Pellet Stove  Adapter  4DT VPSA  can be made with the use of  Selkirk   s Combustion Air Kit  4DT 
2.  side of a structure   check to confirm local code requirements     Atthe time of printing ofthis document  many codes did  not include clear and specific guidelines for the termination  locations for pellet fired appliance incorporating direct  vent systems     Selkirk recommends installing the referenced terminations  in accordance with the guidelines for    Direct Vent     termination locations per NFPA211  These guidelines are     The vent terminal of a direct vent appliance  with an input of 10 000 Btu hr  2930 W  or less      shall be located at least 6 in   152 mm  from any  opening into a building    Appendix A    The vent terminal of a direct vent appliance  with an input of over 10 000 Btu hr  2930 W   but not over 50 000 Btu hr  14 650 W  shall be  located not less than 9 in   229 mm  from any  opening through which vent gases could enter a  building        The vent terminal of a direct vent appliance  with an input over 50 000 Btu hr  14 650 W   shall be located not less than 12 in   305 mm   from the opening     In all cases  the bottom of the vent terminal and  the air intake shall be located at least 12 in    305 mm  above grade        Alternatively  some code authorities may consider these  terminations as    Mechanical Draft Systems    and insist  they be located per NFPA211 requirements for same  In  such case  the following guidelines for minimum distances  from the exit termination to doors  windows  air inlets   etc  are applicable     Terminations for me
3.  with one or more  components  Tee  Short Length  of Selkirk Model VP  L Vent for Pellet Stoves    Minimum Clearance and Framing   Model DT has a 1    minimum airspace clearance to  combustibles requirement when used as L Vent  This  applies whether DT is being used to bring outside air to  the pellet appliance or not       Combustibles    include framing lumber  drywall  plaster   plywood  paneling and other building materials    For penetrating walls  ceiling joists or roof joists the  required framing dimensions are 8 5 8    x 8 5 8     This  will provide a 1    clearance for a properly centered vent   NOTE  While these instructions focus on proper  installation of DT when outside air is being drawn to  appliance  if other sources of combustion air are provided   DT may be used with the combustion air passageway  blocked  still at 1    airspace clearance  ae     DIRECT TEMP     MODEL DT DIRECT VENT INSTALLATION  e INSTRUCTION SUPPLEMENT    USING MODEL 4    DT AS DIRECT VENT FOR PELLET STOVES s    AN WARNING    Failure to follow the installation instructions could cause  FIRE  CARBON MONOXIDE POISONING  OR DEATH  If you    are unsure of installation requirements  call the Phone  Number listed on the instructions  1 800 992 8368 or visit  www selkirkinc com        ADAPTERS  Pellet Stove Adapter  The Pellet Stove Adapter comes with an inlet end that  will properly connect to Selkirk Model VP L Vent and a  standard Model DT outlet  It can be recognized by the  presence of a 3 
4. APPENDIX A    VENTING INSTALLATION  INSTRUCTIONS       Appendix A       ASELKIR    GENERAL   This Instruction Supplement covers important  information for the use adaptation of Model DT Direct  Vent for pellet  corn and other pelletized bio fuel fired  appliance venting applications  In this application Model  DT provides necessary outside combustion air directly  to the appliance    Listing   In addition to being Listed as a direct vent system for gas  fired direct vent appliances  Model DT Direct Vent has  been tested and listed by Underwriters Laboratories  Inc   in accordance with UL641  the Standard for Low  Temperature Gas Venting Systems and ULC ORD   CC441     Pellet Vents    for pellet and corn fired appliance  venting applications  Model DT may also be used for  certain oil fired appliance venting applications and is rated  for flue gas temperatures up to 570   F    NOTE  Refer to the main Model DT Direct Temp  installation Instructions for further details on the use of  this product   Flashings  Supports  Offsets  Adjustables  Etc     Model DT L Vent System may be used for venting gas  or oil fired appliances listed for use with Type L Vent in  addition to Listed pellet and corn burning appliances   Selkirk Metalbestos Model DT has a 4  inner liner and  a 6 5 8    outer jacket  It is permissible to adapt the Model  DT to both a 3    and a 4    pellet stove outlet collar  Model  DT can be adapted to Pellet Stoves with specially  designed Adapters used in conjunction
5. CAK  which comes  with a 3 foot long section of aluminum flexible pipe  3     in diameter  and a hose clamp  Connect the flex pipe by  inserting it into the combustion air snout of the Stove  Adapter  Tighten by using the adapters integrated clamp  tabs  Cut the aluminum flex pipe to the length necessary  to reach the pellet stove combustion air inlet  Fit the alu   minum flex pipe over the pellet stove combustion air in   let    If the diameter  OD  of the inlet is less than 3     make 4  to 6 three inch long parallel cuts equidistant around the  circumference of the flex pipe end  Overlap the cut edges  to reduce the flex pipe end diameter to the diameter of  the stove combustion air inlet  Secure the flex pipe to the  inlet using the hose clamp  See Fig 2     Note  The connection can be made as described with most  non combustible 3    flexible pipe and a hose clamp     Outlet Termination Adapter   The Termination Adapter comes with a standard Model  DT Inlet connection and an outlet that will accommo   date Selkirk   s Decorative Cone Cap  4DT DCC   Exit  Cap  4VP EC   Termination Elbow  DT VPTE  and Ver   tical Cap  VP VC   It can be recognized by the presence  of an extra housing around the outlet end of the adapter  which provides an intake air passage way     NOTE  The intake air passage way must remain free  from obstruction at all times     Connect the adapter to the Model DT by sliding it over  the Direct Vent that is either extending through the wall  or through t
6. chanical draft systems shall be  located     Not less than 3 ft   0 91 m  above any forced air  inlet located within 10 ft  3m      Not less than 4 ft   1 2m  below  4 ft   1 2m   horizontally from  or 1 ft   305m  above any door   window or gravity inlet into any building  and    Not less than 2 ft   0 6m  from an adjacent  building and not less than 7 ft   2 1m  above  grade when located adjacent to public  walkways     So that flue gases are not directed so they  jeopardize people  overheat combustible  structures  or enter buildings     MAINTENANCE REQUIREMENTS   Refer to the appliance manufacturer   s maintenance  instructions for recommendations relative to required  maintenance of your appliance       Model DT L Vent system requires periodic inspection  and cleaning with an appropriately sized brush which will  not scratch the inside surface of the flue  DO NOT USE    chemical cleaners to clean your venting system     Frequency of necessary vent system cleaning will vary    with the appliance  vent system configuration and climate   Certain pellet burning appliances or pelletized fuels may  give off more fine dust than others     1301 W  President George Bush Hwy  Suite 330 Richardson  Texas 75080 1139 1 800 992 VENT  8368        In any case it is recommended that the complete  assembly be inspected and cleaned  if any buildup has  occurred  at the beginning of each heating season and at  least monthly thereafter          TO INSPECT AND CLEAN      Remove the  terminati
7. he roof depending on the type of installation   For through the wall installations using the Termination  Elbow  4DT VPTE   install and attach using one 1 4     stainless steel screw     Attach the Decorative Cone Cap  4DT DCC  or Vertical  Cap  VP HC  to complete the system    See Sections on Vertical Termination  Horizontal Termi   nation and Termination Elbow for more detail   Reference Figs 1 5 for guidance     Appendix A    ENCLOSURES   The vent system should be enclosed in occupied areas   closets  storage rooms  and accessible attics  This does  not apply to the portion of the system that is in the same  room as the Pellet Stove  Enclosures may be built of  ordinary drywall or plywood at the required minimum of  1 INCH AIRSPACE CLEARANCE  There are no special  parts to maintain clearance to inside surfaces of walls or  enclosures  Therefore  the vent installer should take all  necessary precautions to assure that this 1 inch minimum  airspace is maintained    In unoccupied attics  it is very important to be sure that  blown in or other insulation does not come in contact  with the vent system  A full enclosure in the attic should  extend to the roof  However  it need only be finished  well enough to keep insulation and stored furnishings    NG from the vent svstem  i sed  NOTE   Enclosures maintaining the minimum    airspace clearance are especially important in attics  insulated with CELLULOSE type insulation which  may be composed of old newspapers and other  cellulo
8. ne Cap is designed specifically for  use on installations in which the vent terminates in a    horizontal orientation on the outside of a structure   To Install  Slide the Cone Cap onto the Outlet Adapter    or Termination Elbow  if using  until fully seated  Using  the screw and nut provided  tighten the Cone Cap clamp  band around the adapter outlet until a snug fit is achieved   EXIT CAP  VP EC    The Exit Cone Cap is designed to direct flue gases  perpendicular to the wall and to increase their velocity   projecting them further away from the building    Note  When using the Exit Cone Cap  make sure it will  be installed so that the hot flue gases do not overheat any  of the surrounding area or pose any burn hazard to  humans    To Install  Slide the Exit Cone Cap onto the Termination  Adapter until fully seated  While holding cap in place   drill two holes into the adapter using the holes near the  inlet end of Exit Cap as a guide  Secure with screws  provided    TERMINATION ELBOW  4DT VPTE    The Termination Elbow is used in through the wall in   stallations and provides for redirection of exhaust gases  if needed or desired   See Fig  1 and Fig 3    To install  insert the inlet end of the elbow into the outlet  end ofthe Termination Adapter until fully seated  Attach  with one stainless steel   8  1 4    screw    RULES FOR DISTANCES FROM HORIZONTAL  EXIT TERMINATIONS      Before beginning any installation which will result in a  vent cap being installed adjacent to the
9. on cap by removing any screws  then rotating  and pulling until it disengages  Remove the tee cap s  by  removing the stop screw and pulling the cap off  Inspect  system  If necessary clean by running a brush through  the system several times in each direction  NOTE   Be  sure that tee and termination caps are reinstalled and  secured when Inspection Cleaning is completed and  before the system is put back in use     0015208 0906    Appendix A    Venting Parts List    DIRECT TEMP VENTING KITS  Main Level Vent Kit    Basement Vent Kit    Up and Out  Corner Mount Kit    Vertical Termination Kit    ADDITIONAL PARTS  36 inch length vent pipe  24 inch length vent pipe    12 inch length vent pipe    90     elbow   45    elbow   Storm collar   Roof Flashing  Ceiling Support  Trim Plate   Wall thimble  Decorative Cone Cap  Outlet Screen   4   10 inch adjustable pipe   black  4 inch black tee    3 inch black pipe connector    Order Checklist    
10. se materials which are very susceptible to  ignition of a fire    Also the enclosure  by protecting the vent from cold    outdoor temperatures  may improve appliance gra  A vent system enclosure is also recommended for any    exterior systems and portions extending through unheated  areas  This enclosure is helpful in reducing internal  condensation  residue buildup from products of  combustion and metal deterioration    MODEL VP 12    LENGTH AT TERMINATION   It is required to install a 12    length of Model VP at the  Termination Adapter  Push pipe length down onto the  adapter until fully seated  Attach by drilling two holes   opposite each other and approximately 3 4    up from in   let end of pipe  through outer wall and secure with two  1 4    long  8 stainless steel sheet metal screws    See Fig  5    VERTICAL TERMINATION CAP  VP VC    The Vertical Termination Cap is intended for use in all  installations in which the vent terminates in a vertical  orientation  The cap provides necessary protection ofthe  vent system from rain and other elements    To Install  Push the cap down onto the section of Model  VP until the spring clips engage  No additional attachment  is required   See Fig  5    TERMINATION HEIGHT ABOVE ROOF   The  termination of Model VP should be located a sufficient    distance from the roof so that the discharge opening is at  least two  2  feet above the roof surface  or nearby    structure   HORIZONTAL DECORATIVE CONE CAP  4DT DCC     The Decorative Co
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
JOURNAL OFFICIEL - Secrétariat général du gouvernement  josé daniel jales silva - eBiblio  Addendum to TC1766 User`s Manual V2.0    MapKing Pro 2.0.0.1 User Manual  Intermatic T1975R Instructions / Assembly  Operating instructions Robot vacuum cleaner Mode d`emploi du  FRONTLINE TEST SYSTEM™ - Frontline Test Equipment  ASUS B53S User's Manual  Cognac Mag 53 nov-dec 2013    Copyright © All rights reserved. 