Home
        OneTouch® UltraMini® User Guide Canada English
         Contents
1.        LL mmol L M    Press W to move to the previous result stored in the meter  Then  press A or Y  to move forward or backward through all of your results  When you re finished  reviewing past results  press and hold W for two seconds until the meter turns off        NOTE  lf no results are currently stored in the meter                will appear on the display     REVIEWING PAST RESULTS  16       Downloading results to a computer    You can use your meter with OneTouch   Diabetes Management Software  DMS  for storing your records and to help you spot patterns for  planning meals  exercise  and medication  OneTouch   DMS puts information downloaded from the meter into charts and graphs  If you  are a current OneTouch   DMS user  additional software updates may be required for use with the OneTouch   UltraMini   Meter  Please  visit www OneTouch ca       Obtain the required software and cable  For order information and to learn more about OneTouch   Diabetes Management  Software visit www OneTouch ca        Install the software on a computer  Follow the installation instructions provided with the Software  If using a  OneTouch   Interface Cable  USB format   install the software driver  Interface Cable         A WARNING  To avoid a possible shock  Do Not insert a test strip  when the meter is connected to a computer with the OneTouch    Interface Cable           Get ready to transfer readings   Connect the OneTouch   Interface Cable to the COM or USB port on your computer  
2.     Repeat the test with a new test strip   Apply a blood or control solution  sample only after the flashing blood  drop icon    amp  appears on the display   If this message continues to appear   contact the OneTouch   Customer Care  Line at 1 800 663 5521     ERROR MESSAGES AND DETAILS ABOUT YOUR SYSTEM    25       What it means    One of the following may apply   You may have high glucose and have  tested in an environment near the  low end of the system   s operating  temperature range  6   44        or     There may be a problem with the test  strip  For example  it may have been  damaged or moved during testing   or     The sample was improperly applied   or     There may be a problem with the meter     The meter has detected a problem with  the test strip  Possible causes are test  strip damage or an incompletely filled  confirmation window     power to perform a test     The   icon flashes on the display by itself  when there is not enough battery power    to perform a test or view previous results     26    What to do    If you tested in a cool environment  repeat    the test in a warmer environment with  a new test strip  see Section 3  Testing  your blood glucose  If this error message  appears again  contact the OneTouch    Customer Care Line at 1 800 663 5521     If you tested in a normal or warm  environment  repeat the test with a new  test strip  see Section 3  Testing your blood  glucose  If this error message appears  again  contact the OneTouch   Customer 
3.  4 2  This meter has been tested for immunity  to radio frequency interference over the frequency range 80 MHz to 2 5 GHz at 3 V m as specified in IEC 61000 4 3  Degree of protection rating   Minimum of IP2X  This meter complies with CISPR 11 2003  Class B  Radiated Only   Emissions of the energy used are low and are not likely to  cause interference in nearby electronic equipment     TA CAN CSA  22 2 61010 1 04  UL 61010 1 04  IEC 61010 1 and IEC 61010 2 101   Cs    Guarantee  LifeScan guarantees that the OneTouch   UltraMini   Meter will be free of defects in material and workmanship for three years  valid from the date  of purchase  The guarantee extends only to the original purchaser and is not transferable     Notes    Your target ranges  from your healthcare  professional    Reminders    Time of day    Fasting  Before lunch or dinner  2 hours after meals    Between 2 a m  and 4a m        ERROR MESSAGES AND DETAILS ABOUT YOUR SYSTEM  28    
4.  Care Line at 1 800 663 5521     If you applied the sample incorrectly   review blood application  see Section 3   Testing your blood glucose  or control  solution testing  see Section 5  Control  solution testing  and repeat the test with a  new test strip  If the error message appears  again  contact the OneTouch   Customer  Care Line at 1 800 663 5521     If this error message appears again  contact  the OneTouch   Customer Care Line  at 1 800 663 5521     Repeat the test with a new test strip   Refer to blood application  see Section 3   Testing your blood glucose  or control  solution testing  see Section 5  Control  solution testing      Meter battery is low but there is enough    When the flashing battery icon first  appears  there is enough power for a  minimum of 100 more tests  Test results  will still be accurate  but replace the  battery as soon as possible     Replace the meter battery     ERROR MESSAGES AND DETAILS ABOUT YOUR SYSTEM       Detailed information about your system    Comparing meter and laboratory results   Test results with the OneTouch   UltraMini   Meter are plasma calibrated  This helps you and your healthcare professional to compare your  meter results with laboratory tests  If you have been using another type of meter   one that provides whole blood calibrated results   you  may notice that your test results with the OneTouch   UltraMini   Meter are approximately 12  higher  OneTouch   UltraMini   Meter test results  and laboratory test result
5.  after completing a test  remove the test strip  at 1 800 663 5521        GETTING TO KNOW YOUR SYSTEM  3       Setting the time and date  and preparing for a test       Setting the time and date    Your OneTouch   UltraMini   Meter comes with the time  date and unit of measure pre set  Before using your meter for the first time or if  you change the meter battery  you should check and update the time and date  Make sure you complete steps 1 to 7 below to ensure your  desired settings are saved       A WARNING  If your display shows mg dL rather than mmol L  contact the OneTouch   Customer Care Line at  1 800 663 5521  You cannot change the unit of measure  Use of the wrong unit of measure may cause you to  misinterpret your blood glucose level  and may lead to incorrect treatment          Turn the meter on   Press and hold    for five seconds until the start up test screen appears    After the test screen  the pre set time and date will appear on the display for five  seconds  The hour will now start flashing     NOTE  lf a setting does not need to be updated  simply wait five seconds   The meter display will automatically advance to the next setting        Set the hour  With the hour flashing on the display  press and release A or W to go forward or  backward one hour  To move faster  hold the A or W buttons down        When the correct hour appears on the display  wait five seconds  Your entry will be saved  and you will move to the next setting  The minutes will now start 
6.  blood       approximate size  forms on your fingertip  If the blood smears or runs    Do Not use that sample  Wipe the area and gently squeeze another drop of blood  or puncture a new site     TESTING YOUR BLOOD GLUCOSE  9    Choosing the right sampling site at the right time   The OneTouch   UltraMini   Meter allows you to sample blood from your fingertip  forearm or palm  Forearm and palm sampling is also referred  to as    alternate site testing     AST   At times  results obtained at the forearm or palm may be different from a fingertip measurement  Talk to  your healthcare professional before you begin using your forearm or palm for sampling     If you are testing  Use blood sample from your     Routinely before meals   Prior to or more than two hours after     a meal Fingertip  forearm  or palm  e a rapid acting insulin injection or insulin pump bolus  e exercise    When your blood glucose is changing rapidly  such as   e within two hours after a meal  e within two hours after a rapid acting insulin injection or insulin pump bolus  or  e during or within two hours after exercise   When you are concerned about the possibility of hypoglycemia  low blood sugar     Fingertip      A CAUTION  Do Not test on your forearm or palm when    e You think your blood glucose is rapidly falling  such as within two hours of exercise or a rapid acting insulin injection or insulin pump  bolus  Testing with a fingertip sample may identify hypoglycemia or an insulin reaction sooner than te
7.  hands and forearm  if applicable   thoroughly with warm  soapy water  Rinse and dry            Lancing and sampling from your fingertip    Remove the blue  or black  cap by snapping it off          Insert a sterile lancet into the lancing device   Insert the lancet into the holder and push in firmly  Twist the protective disk  until it separates from the lancet and save the disk for later use    Do Not twist the lancet        Replace the blue  or black  cap by snapping it back on       Adjust the depth setting  The lancing device has nine puncture depth settings  numbered 1 through 9  The smaller numbers are for a  shallower puncture  and the larger numbers are for a deeper puncture  Shallower punctures work for children and  most adults  Deeper punctures work well for people with thick or callused skin  Twist the blue  or black  cap until  the correct setting appears     NOTE  A shallower puncture may be less painful  Try a shallower setting first and increase the depth until you  find the one deep enough to get a large enough drop of blood     approximate size         Cock the lancing device  Slide the cocking control back until it clicks  If it does not click  it may have been cocked when you inserted  the lancet        Puncture your finger  Hold the lancing device firmly against the side of your finger  Press the release button  Remove the lancing device  from your finger       Get a round drop of blood   Gently squeeze and or massage your fingertip until a round drop of
8.  meter       A CAUTION  Do Not swallow control solution  it is not for human consumption  Do Not apply control solution to the skin or eyes  as it may cause irritation        How to test with control solution    Start with the meter off  If you have turned the meter on to change settings or review past results  turn it off       Insert a test strip to turn on the meter  Make sure the three contact bars are facing you  Push the test strip in as far as it will go  Do Not bend the  test strip     The display will advance to the screen with the flashing blood drop icon               Mark the test as a control solution test  IMPORTANT    Mark all control solution tests with CtL  This will stop them from being  stored as blood glucose results   e Control solution results marked with CtL are not stored in the meter   s  memory  mmol L  Press A So that the control solution test symbol CtL appears in the upper right corner  of the display  You must mark the test before you apply control solution  Once you have  completed the test  you cannot change the marking  The meter is now ready to perform  a control solution test  If you decide not to do a control solution test  press    again to mmol L  remove CtL from the display        CONTROL SOLUTION TESTING  18       Prepare and apply control solution    oo    oo    a  Shake the control solution vial before each test  Remove the cap and squeeze the vial to S St  discard the first drop  Then wipe the tip with a clean tissue or cloth  Hold t
9.  off by removing the test strip     Removing the used lancet   Remove the lancing device cap by snapping it off  Cover the exposed lancet tip before removing  the lancet  Place the lancet protective disk on a hard surface  Push the lancet tip into the disk  Remove  the lancet and place it in a container for sharp objects  Replace the cap     Disposing of the used lancet and test strip   It is important to discard the used lancet carefully after each use to avoid unintended lancet stick  injuries  Used test strips and lancets may be considered biohazardous waste in your area  Be sure to  follow your local regulations or your healthcare professional s recommendations for proper disposal        TESTING YOUR BLOOD GLUCOSE  15      Reviewing past results       Reviewing past results    The meter stores a maximum of 500 blood glucose test results  When the meter memory is full  the oldest result is dropped as the  newest is added  Results are stored automatically when you test  along with the time  date and unit of measure  You can review the  results stored in the meter memory  starting with the most recent     If your meter is off  press and release W to turn it on  After the start up test  screen  your most recent test result will appear on the display     M    also appears  to indicate memory mode        If you have just completed a test  leave the test strip in the meter and press Y  to enter the memory mode  Your most recent blood glucose test result appears  along with    M 
10.  on the test strip vial  Do Not use the  meter  the test strips  or the control solution  Call the OneTouch   Customer Care Line at 1 800 663 5521        CONTROL SOLUTION TESTING  19      Caring for your system       Replacing the battery    Your OneTouch   UltraMini   Meter uses one 3 0 Volt CR 2032 lithium battery  or equivalent   Replacement batteries can be found in  most stores where batteries are sold  Your meter comes with the battery already installed  A battery icon   appears in the far right   hand side of the meter display to indicate low battery     When there is enough power for a minimum of 100 more tests  the battery icon  will appear     After each test and when reviewing past results  the battery icon will now flash to  remind you to change the battery as soon as possible        When the battery icon is flashing by itself on the display  you cannot perform a  test  You must install a new battery before using your meter        Replacing the battery      Remove the old battery  Start with the meter off  Open the battery door and pull up on the battery ribbon        CONTROL SOLUTION TESTING  20      A WARNING  To avoid a possible shock  Do Not change the battery while the meter is connected to a computer with the    OneTouch   Interface Cable           Insert the new battery   With the         side facing up toward you  place the battery in the compartment within the fold of the ribbon   Push the battery until it snaps into place  Insert the two battery door tab
11.  smear the blood sample     NOTE    e You may need to wait a little longer to get a large enough drop of blood from the forearm or palm  Do Not squeeze the site excessively    e Ifthe sample drop of blood runs or spreads due to contact with hair or with a line in your palm  Do Not use that sample  Try puncturing  again in a smoother area    e Remember  You may have to adjust the lancing device to a deeper setting to get a large enough drop of blood     approximate size         Applying blood and reading results    Once you have a blood sample and your meter shows the screen with the flashing blood drop icon    amp    you are ready to obtain a blood  glucose result  If your meter does not show the screen with the flashing blood drop icon    amp    remove the unused test strip and re start the  test process  See Getting a blood sample in Section 3       Prepare to apply the sample  Keeping your finger extended and steady  move the meter and test strip toward the blood drop     Do Not apply blood on the top of the test strip   Do Not hold the meter and test strip underneath    the blood drop  This may cause blood to run into  the test port and damage the meter              When applying a drop of blood from your forearm or palm  keep your palm or  forearm steady and bring the top edge of the test strip to the drop of blood with your  other hand        Forearm Palm    TESTING YOUR BLOOD GLUCOSE  12       Apply the sample  Line up the test strip with the blood drop so that the nar
12. Make sure the meter is turned off  If you insert the  cable while the meter is already on  the meter will not respond to computer commands  Then connect the other end of the OneTouch    Interface Cable to the meter data port    2       Transfer data   Follow the instructions provided with OneTouch   DMS to download the results from the meter  Once the  command to start the download is sent from the computer to the meter  the meter display will show    PC     indicating that the meter is in communication mode  You will not be able to perform a test when the meter  is in communication mode        REVIEWING PAST RESULTS  17      Control solution testing    When to test with control solution       OneTouch   Ultra   Control Solution contains a known amount of glucose and is used to check that the meter and the test strips are working    properly    Do a control solution test    e to practice the test process instead of using blood  NOTE    e once a week  e Use only OneTouch   Ultra   Control Solution with your OneTouch     e whenever you open a new vial of test strips  UltraMini   Meter    e if you suspect the meter or test strips are not working properly  e Control solution tests must be done at room temperature   e if you have had repeated unexpected blood glucose results as  20   25  C   Make sure your meter  test strips  and control solution  described in Applying blood and reading results in Section 3  or are at room temperature before testing     e if you drop or damage the
13. ONE  OUCH  UltraMini    Blood Glucose Monitoring System    USER GUIDE       AW 06720301A    Contents       Getting to know your system 1       2  Setting the time and date  and preparing for a test    3 Testing your blood glucose         Reviewing past results      Control solution testing    Q Caring for your system    7  Error messages and details about your system       Patent information   The system described herein is covered by one or more of the following U S  patents  5 708 247  5 951 836  6 241 862  6 284 125   7 112 265 and D546 216  Use of the monitoring device included herein is protected under one or more of the following U S  patents   6 413 410  6 733 655  7 250 105  7 468 125  Purchase of this device does not act to grant a use license under these patents in any  jurisdiction outside Canada  A license for use in Canada is granted only when the device is used with OneTouch   Ultra   Test Strips    No test strip supplier other than LifeScan is authorized to grant such a license  The accuracy of results generated with LifeScan meters  using test strips manufactured by anyone other than LifeScan has not been evaluated by LifeScan     OneTouch   Customer Care Line   Monday Friday 9am 8pm Eastern Time  6am 5pm Pacific Time  Canada 1 800 663 5521   USA 1 800 227 8862    Or   Visit us at www OneTouch ca    If you cannot reach the OneTouch   Customer Care Line  contact your healthcare professional for advice     Manufactured by  Distributed by   LifeScan Europe LifeSc
14. an Canada Ltd   Division of Cilag GmbH International Burnaby  B C  V5C 6C6  6300 Zug  Switzerland  Pa ie CHAN   amp  LIF  ES    2010 LifeScan  Inc     afohmonsfohwon company Trademarks owned by Johnson  amp  Johnson and used under license     Before you begin   Before using this product to test your blood glucose  carefully read this User Guide and the inserts that come with the OneTouch    Ultra   Test Strips and OneTouch   Ultra   Control Solution  Take note of warnings and cautions throughout this User Guide  which are  identified with A  Many people find it helpful to practice the test with control solution before testing with blood for the first time   See Section 5  Control solution testing     Intended use  The OneTouch   UltraMini   Blood Glucose Monitoring System is intended to be used for the quantitative measurement of glucose     sugar  in fresh capillary whole blood  The OneTouch   UltraMini   System is intended for self testing outside the body  in vitro  diagnostic use  by people with diabetes at home and by healthcare professionals in a clinical setting as an aid to monitor the  effectiveness of diabetes control  It should not be used for the diagnosis of diabetes or for testing newborns     Test principle   Glucose in the blood sample mixes with special chemicals in the test strip and a small electric current is produced  The strength  of this current changes with the amount of glucose in the blood sample  Your meter measures the current  calculates your bloo
15. d  glucose level  displays the result  and stores it in its memory          Getting to know your system       The OneTouch   UltraMini   Blood Glucose Monitoring System    Included with your kit     a  OneTouch   UltraMini   Meter  battery included     b  Lancing Device  c  Sterile Lancets  d  Carrying Case       If any of these items are missing from your kit  call  OneTouch   Customer Care Line 1 800 663 5521     Available separately     e  Blue OneTouch   Ultra   Test Strips  f  OneTouch   Ultra   Control Solution  g  Clear Cap for AST testing    Ask for control solution where you buy  your test strips or call the OneTouch    Customer Care Line at 1 800 663 5521        b OS       J      A WARNING  Keep the meter and testing  supplies away from young children  Small  items such as the battery door  battery     test strips  lancets  protective disks on the  lancets and control solution vial cap are  choking hazards        GETTING TO KNOW YOUR SYSTEM    1    Getting to know your system       Up and down buttons  Turns the meter on or off    Test port Display mmol L is the pre   Insert test strip here to set unit of measure  turn meter on for testing            Select or change information         METER   ONETOUCH          Lltralini       ONE cH tre Contact bars  ans UC ra     TEST STRIP et a9 ON EW ci o n Insert into test port  Actual test strip is blue apply sample TO i   Confirmation  window    GETTING TO KNOW YOUR SYSTEM  2    Turning your meter on    gt   lt        D  To 
16. e immediate  treatment according to your  healthcare professional   s  recommendations  Although this  message could be due to a test error   it is safer to treat first and then do  another test     Re check your glucose level  If the  result is HI again  obtain and follow  instructions from your healthcare  professional without delay     Repeat the test after the meter and  test strips have reached a temperature  within the operating range     Repeat the test after the meter and  test strips have reached a temperature  within the operating range     ERROR MESSAGES AND DETAILS ABOUT YOUR SYSTEM    24    mmol L M    No result in memory  such as the first  time use of the meter    Or    Your meter was unable to recall this  result     Error message indicates there is a  problem with the meter     Error message could be caused either  by a used test strip or a problem with  the meter     Error message indicates that the blood  or control solution sample was applied  before the meter was ready     You can still perform a blood glucose  test and get an accurate test result   Contact the OneTouch   Customer Care  Line at 1 800 663 5521 to report this  occurrence if this is not your first time  use of the meter     Do Not use the meter   Contact the OneTouch   Customer Care  Line at 1 800 663 5521     Repeat the test with a new test strip   see Section 3  Testing your blood  glucose  If this message continues   to appear  contact the OneTouch    Customer Care Line at 1 800 663 5521 
17. end of the operating range  6   44  C  and your glucose is high  over 10 0 mmol L   the  reading on your meter may be lower than your actual glucose  In this situation  repeat the test in a warmer environment  with a new test strip as soon as possible       A WARNING  If mmol L does not appear with the test result  call the OneTouch   Customer Care Line at  1 800 663 5521  Use of the wrong unit of measure may cause you to misinterpret your blood glucose level   and may lead to incorrect treatment        Error messages  If you get an Er message on your screen rather than a result  see Understanding error and other messages in Section 7     Unexpected test results  Refer to these cautions Z  whenever your results are lower than  higher than  or otherwise not what you expect     TESTING YOUR BLOOD GLUCOSE  14      A CAUTION  Dehydration and low glucose results  Severe dehydration resulting from excessive water loss may cause false low results  If you think you are suffering from severe  dehydration  contact your healthcare professional immediately       A CAUTION  Low glucose results   If your test result is lower than 3 9 mmol L or is shown as LO  it may mean hypoglycemia  low blood glucose   This may  require immediate treatment according to your healthcare professional   s recommendations  Although this result could be  due to a test error  it is safer to treat first  then do another test       A CAUTION  High glucose results   If your test result is higher than 10 0 mmol L  
18. flashing        Set the minutes  Press  amp  or W to change the minutes  When you have the correct minutes on the  display  wait five seconds to move to the next setting  AM or PM will now start flashing        GETTING TO KNOW YOUR SYSTEM  A       Set AM or PM      AM    or    PM    will be displayed next to the minutes  Press A or W to set AM or PM  then  wait five seconds to move to the next setting  The year  last two digits only   month and day  appear on the display and the year flashes        Set the year  Press A or Y to change the year  When you have the correct year on the display  wait five  seconds to move to the next setting  The month will now start flashing        Set the month  Press A or W to change the month  When you have the correct month on the display  wait  five seconds to move to the next setting  The day will now start flashing       Set the day  Press A or W to change the day  When you have the correct day on the display  wait five  seconds to move to the next screen     Your time and date settings will be displayed for five seconds  After the five seconds  the  settings will be saved and the meter will then turn off  If you want to adjust your settings   press A or W while the time and date are still on the display  You will be returned to the  first set up screen where you can begin with the hour     GETTING TO KNOW YOUR SYSTEM    5    N                  l     ION          Preparing for a test    Have these things ready when you test your blood gluc
19. he vial upside Edae    down and gently squeeze a hanging drop  Touch and hold the hanging drop of control ge A  solution to the narrow channel in the top edge of the test strip  Make sure the confirmation Narrow Channel  window fills completely  Control solution should not be applied to the flat face of the Apply drop here       test strip        Read your result  When the confirmation window is full  the meter will count down from 5 to 1  Your result will then Confirmation  appear on the display  along with CtL and the unit of measure  Window             Check if the result is in range   Compare the result displayed on the meter to the control solution range printed on the test strip vial  Each vial of  test strips may have a different control solution range  If the results you get are not within this range  the meter and  test strips may not be working properly  Repeat the control solution test     Out of range results may be due to   e not following the instructions detailed in steps 1   5   e expired or contaminated control solution   e expired or damaged test strip   e use of a test strip or control solution past its discard date  or  e a problem with the meter        5 5 7 4 mmol L   Example       A CAUTION  The control solution range printed on the test strip vial is for OneTouch   Ultra   Control Solution only  It is nota  recommended range for your blood glucose level       A CAUTION  If you continue to get control solution results that fall outside the range printed
20. it may mean hyperglycemia  high blood glucose   If you are uncertain about  this test result  consider re testing  Your healthcare professional can work with you to determine what actions  if any  you  should take if your results are higher than 10 0 mmol L     If your meter displays HI  you may have a very high blood glucose level  severe hyperglycemia  exceeding 33 3 mmol L   Re check your glucose level  If the result is HI again  this may indicate a severe problem with your blood glucose control and  it is important you obtain and follow instructions from your healthcare professional without delay       A CAUTION  Repeated unexpected glucose results   If you continue to get unexpected results  check your system with control solution  See Section 5  Control solution testing   If you are experiencing symptoms that are not consistent with your blood glucose results and you have followed all  instructions in this User Guide  call your healthcare professional  Never ignore symptoms or make significant changes to  your diabetes control program without speaking to your healthcare professional       A CAUTION  Unusual red blood cell count  A hematocrit  percentage of your blood that is red blood cells  that is either very high  above 55   or very low  below 30    can cause false results        After getting a result   Once you have read your result  you may    e Review your meter memory by pressing W to enter memory mode  see Section 4  Reviewing past results  or  e Turn the meter
21. lary blood obtained from the fingertip      Do Not eat for at least eight hours before you test your blood  e Follow all instructions in this User Guide for performing a   e Take your meter with you to the lab  blood glucose test with your meter     1  Sacks  D B      Carbohydrates     Burtis  C A   and Ashwood  E R   ed    Tietz Textbook of Clinical Chemistry  Philadelphia  W B  Saunders Company  1994   959     Technical specifications    Reported result range 1 1   33 3 mmol L Memory 500 blood glucose test results  Calibration Plasma equivalent Automatic shutoff 2 minutes after last action  Sample Fresh capillary whole blood Size 10 8 x 3 20 x 1 70 cm  Test time 5 seconds Weight Approximately 40 grams  with battery  Assay method Glucose oxidase biosensor Operating ranges Temperature  6   44  C  Meter power source One replaceable 3 0 Volt CR 2032 Altitude  up to 3048 meters   lithium battery  or equivalent  Relative humidity  10   90   Unit of measure mmol L Hematocrit  30 55    Battery ratings One 3 0 V d c   3 mA   one CR 2032 battery         direct current    ERROR MESSAGES AND DETAILS ABOUT YOUR SYSTEM  27    Symbols    A Cautions and Warnings  Refer to safety related notes in the User Guide and inserts that came with your meter and testing supplies         Direct current Low battery  SN  Serial Number In vitro diagnostic medical device    Electrical and safety standards   The meter has been tested for immunity to Level 4 electrostatic discharge as specified in IEC 61000
22. ntamination or damage  Store test strips only in their original vial     Checking for expiration or damage to test strips and control solution  Test strips and control solution have expiration dates printed on their vials  When you first open a test strip or control solution vial  you must  record the discard date in the space provided on the label     e Test Strips  date opened plus six  6  months  e Control Solution  date opened plus three  3  months      A CAUTION  Do Not use the test strips or control solution after the expiration date printed on the vial or the discard date  whichever  comes first  or your results may be inaccurate       A CAUTION  Do Not use your test strips if your vial is damaged or left open to air  This could lead to error messages or tests that read  higher than the actual value  Call the OneTouch   Customer Care Line at 1 800 663 5521 immediately if the test strip vial is damaged        CONTROL SOLUTION TESTING  22    Cleaning your meter  To clean your meter  wipe the outside with a soft cloth dampened with water and mild detergent  Do Not use alcohol or another solvent to clean  your meter     Do Not get any liquids  dirt  dust  blood  or control solution inside the meter through the test port or the data port  Never spray cleaning solution  on the meter or immerse it in any liquid     Cleaning your lancing device and clear cap  To clean these items  wipe them with a soft cloth dampened with water and mild detergent  Do Not immerse the lancing de
23. ose level     e OneTouch   UltraMini   Meter e Lancing device e OneTouch   Ultra   Control Solution  e OneTouch    Ultra   Test Strips e Sterile lancets with protective disks  NOTE     e Use only OneTouch   Ultra   Test strips   the blue strip with the OneTouch   Ultra   logo on the front   with your OneTouch   UltraMini   Meter   e Unlike some blood glucose meters  no separate step to code your OneTouch   UltraMini   Meter System is required  The code on the  test strip vial does not apply to this meter   e Make sure your meter and test strips are about the same temperature before you test   e Testing must be done within the operating temperature range  6   44  C   For the most accurate results  try to test as close to room  temperature  20   25  C  as you can       A CAUTION  If you cannot test due to a problem with your testing supplies  contact your healthcare professional or the OneTouch    Customer Care Line at 1 800 663 5521  Failure to test could delay treatment decisions and lead to a serious medical condition       A CAUTION  The test strip vial contains drying agents that are harmful if inhaled or swallowed and may cause skin or eye irritation        GETTING TO KNOW YOUR SYSTEM  6    Insert a test strip to turn on the meter   Start with the meter off  If you have turned the meter on to change settings or review past results  turn  it off  Remove a test strip from its vial  With clean  dry hands  you may touch the test strip anywhere on  its surface  Do Not bend  cu
24. perform a test  insert a test strip as far as it will go  The display will turn on and    I f pie   the meter will briefly perform system checks  Or  to change the time and date  ee E ar  start with the meter off  then press and hold W for five seconds until the start u   I i      mg d L  RNP i Up  Ta a    ees MMOol  LM  test screen appears  After the start up test screen  the pre set time and date will  appear on the display  Or  if you want to turn the meter on to review past results   start with the meter off  then press and release W     z oo  Iu    a a   UD   lt E          Start up Test Screen    Every time you turn your meter on  a start up test screen will appear for two seconds  All segments of the display should appear  briefly on the start up test screen to tell you that the meter is working properly  To check that all display segments are working  as  soon as the start up test screen appears  press and hold A to keep the start up test screen display on  Release    to proceed to the  next step  If the meter does not power on  try changing the meter battery  See Replacing the battery in Section 6     Turning your meter off   There are several ways to turn your meter off    A CAUTION  If any information is missing from the  e Press and hold W for two seconds  when reviewing past results  Start up test screen  there may be a problem with   e Your meter will turn off by itself if left alone for two minutes  the meter  Call the OneTouch   Customer Care Line   e Before or
25. row channel on the edge of  the test strip is almost touching the edge of the blood drop        Narrow Channel    Gently touch the channel to the edge of the blood drop     Be careful not to push the test strip against your fingertip or the test strip may  not fill completely        NOTE    e Do Not smear or scrape the drop of blood with the test strip    e Do Not apply more blood to the test strip after you have moved the drop of blood away   e Do Not move the test strip in the meter during a test       A CAUTION  You may get an Er 5 message or an inaccurate result if the blood sample does not fill the confirmation window  completely  See Understanding error and other messages in Section 7  Discard the test strip and re start the test process         1O Q  r   d            Wait for the confirmation window to fill completely  The blood drop will be drawn into the narrow channel and the confirmation  window should fill completely         When the confirmation window is full  this means you have applied enough  blood  Now you can move the test strip away from the blood drop and wait  for the meter to count down from 5 to 1     Full Not Full       Confirmation Window    TESTING YOUR BLOOD GLUCOSE  13       Read your result on the meter   Your blood glucose level appears on the display  along with the unit of  measure  and the date and time of the test  Blood glucose results are  automatically stored in the meter   s memory         Example       A CAUTION  If you test at the low 
26. s both are expressed in plasma equivalent units  However  your meter result may differ from your laboratory result  due to normal variation  Meter results can be affected by factors and conditions that do not affect laboratory results in the same way     Your OneTouch   UltraMini   Meter glucose value is considered accurate when it is within  20  of the laboratory measurement  There are some  specific situations that could cause a difference of more than  20      e You have eaten recently  The blood glucose level from a fingertip can be up to 3 9 mmol L higher than blood drawn from a vein  venous  sample  used for a lab test       e Your hematocrit  percentage of blood that is red blood cells  is high  above 55   or low  below 30      e You are suffering from severe dehydration    e You tested at a temperature near the low end of the operating range  6  C  and you get a high glucose result  i e   greater than 10 0 mmol L    In this situation  repeat the test in a warmer environment with a new test strip as soon as possible     For accuracy and precision data and for important information on limitations  see the insert that comes with your test strips  To maximize your  chances of an accurate comparison between meter and laboratory results  follow a few basic guidelines     Before going to the lab While at the lab   e Perform a control solution test to make sure the meter is e Conduct your meter test within 15 minutes of the lab test   working properly  e Use only fresh  capil
27. s into the matching holes  and push  down until you hear the door click into place     If the meter does not power on after you have replaced the battery  check that the battery is correctly  installed with the         side up  If the meter still does not power on  call the OneTouch   Customer Care Line  at 1 800 663 5521           Check the time and date   After replacing the battery  turn the meter on by pressing and holding the W button for five seconds to access the set up mode  The start up  test screen will be briefly displayed  then the date and time will appear in the top right corner of the display  Check that the time and date  are set correctly  If they are not  use the    and    buttons to re set the meter before testing  See Setting the time and date in Section 2     NOTE  Removing the meter battery will not affect your stored results  However  you may need to re set the time and date        Dispose of batteries according to your local environmental regulations    CONTROL SOLUTION TESTING  21       Caring for your system    Your OneTouch   UltraMini   Blood Glucose Monitoring System does not need any special maintenance     Storing your system   Store your meter  test strips and control solution in your carrying case after each use  Store each item in a cool  dry place below 30  C  but  Do Not refrigerate  Keep all items away from direct sunlight and heat  Tightly close the cap on the test strip vial and or control solution vial  immediately after use to avoid co
28. sting with a forearm or palm  sample     e It has been less than two hours after a meal  a rapid acting insulin injection or insulin pump bolus  physical exercise  or you think your  glucose level is changing rapidly    e You are concerned about the possibility of hypoglycemia or an insulin reaction  such as when driving a car  This is especially important if  you suffer from hypoglycemia unawareness  lack of symptoms to indicate an insulin reaction         TESTING YOUR BLOOD GLUCOSE  10    Remember  Consult with your healthcare professional before using your forearm or palm for testing     Choose a different puncture site each time you test  Repeated punctures in the same spot may cause soreness and calluses  If bruising occurs at  an alternate site or you have difficulty getting a sample  consider sampling from a fingertip instead  You may want to review the choice of sites  with your healthcare professional     Lancing and sampling from an alternate site   Sampling from your palm or forearm allows you to use your fingertips less often  You may find that obtaining a blood sample from an  alternate site is less painful than using a fingertip  Getting a blood sample from your forearm or palm is different than getting a sample from  your fingertips     Forearm sampling   Choose a fleshy area of the forearm away from bone  visible veins and hair   Sometimes there is less blood flow to the forearm than to the fingertips  To help you  get a large enough drop of blood  you may gen
29. t or modify the test strips in any way  Use each test strip immediately after  removing it from the vial        Hold the meter as shown and insert the test strip into the test port  Make sure the three contact bars are  facing you  Push the test strip in as far as it will go  Do Not bend the test strip     The display will advance to the screen with the flashing blood drop icon  amp           A CAUTION  OneTouch   Ultra   Test Strips are for single use only  Never re use a test strip that had either blood or control       solution applied to it     GETTING TO KNOW YOUR SYSTEM  7       Testing your blood glucose       Getting a blood sample    Overview of the Lancing Device    Clear Cap    for alternate site sampling   Release button        Cocking control            Blue  or black  cap        for fingertip sampling   Sterile lancet  Lancet point     The blue  or black  cap and clear cap are also used for depth adjustment  NOTE   f you do not have a lancing device  please refer to the instructions that came with your lancing device       A CAUTION  To reduce the chance of infection   Make sure to wash the puncture site with soap and water before e Always use a new  sterile lancet   lancets are for single use only     sampling  e Keep your meter and lancing device clean  See Caring for your  e Never share a lancet or a lancing device with anyone  system in Section 6        TESTING YOUR BLOOD GLUCOSE  8    Preparing your sample site  Before you test your blood glucose  wash your
30. tly massage or apply warmth to the  site to increase blood flow     Palm sampling  Choose a fleshy area on the palm below your thumb or little pinky finger  Select a  spot with no visible veins and away from deep lines  which may cause your blood  sample to smear        Forearm Palm    The clear cap is used for forearm and palm sampling only  Replace the blue  or black  cap with the clear cap     Insert a sterile lancet and snap on the clear cap       Adjust the depth setting   You may have to adjust the lancing device to a deeper setting to get a large enough  drop of blood from your forearm or palm  Twist the clear cap toward the larger  numbers to increase the depth        Be sure to cock the lancing device        Puncture your forearm or palm   Firmly press and hold the lancing device against your forearm or palm for a few  seconds  Wait until the skin surface under the clear cap changes color    as blood collects beneath the skin   This tells you there is enough blood  flow for a good sample  Then press the release button while continuing to apply  pressure  Keep holding the lancing device against your skin until a round drop of  blood forms under the cap  Forearm Palm       TESTING YOUR BLOOD GLUCOSE  11    When sampling blood from your forearm or palm  make sure the drop of blood is large enough     approximate size  before you release  pressure and remove the lancing device        Remove the lancing device  Carefully lift the lancing device away from your skin  Do Not
31. vice in any liquid     To disinfect these items  prepare a solution of one part household bleach to ten parts water  Wipe the lancing device with a soft cloth dampened  with this solution  Immerse the caps only in this solution for 30 minutes  After disinfecting  rinse briefly with water and allow both to air dry     CONTROL SOLUTION TESTING  23    7  Error messages and details about your system       Understanding error and other messages    The OneTouch  UltraMini   Meter displays messages when there are problems with the test strip  with the meter  or when your  blood glucose levels are higher than 33 3 mmol L or lower than 1 1 mmol L  Messages do not appear in all cases when a problem  has occurred  Improper use may cause an inaccurate result without producing a warning message     Message What it means       level  severe hypoglycemia   lower  than 1 1 mmol L     mmol L    You may have a very high blood    mm   D   gt        over 33 3 mmol L        mmol L    The meter has detected that the  temperature is above the system  operating range  Do Not perform a  test until the meter and test strips  reach a temperature within the  operating range of 6   44  C     The meter has detected that the  temperature is below the system  operating range  Do Not perform a  test until the meter and test strips  reach a temperature within the  operating range of 6   44  C     M  You may have a very low blood glucose    glucose level  severe hyperglycemia      What to do    This may requir
    