1. CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit A CAUTION This device is intended for use in measuring blood pressure and pulse rate in the adult population Do not use this device on infants or persons who cannot express their intentions APPLYING THE CUFF ON THE LEFT ARM 1 Make sure the air plug is securely inserted in the main unit 2 Remove tight fitting clothing from your upper arm 3 Apply the cuff to your left upper arm so Left Arm the arrow is centered on the inside of your arm and aligned with your middle finger The air tube runs down the inside of your arm The bottom of the cuff should be approximately 1 2 above your elbow 1 2 inch 1 2 cm 4 Wrap the cuff firmly in place around your arm using the cloth fastening APPLYING THE CUFF ON THE RIGHT ARM When taking a measurement using the right arm use this instruction for Step 3 Apply the cuff to your right upper arm so Right Arm the arrow and the air tube runs along the inside of your arm The bottom of the cuff should be approximately 1 2 above your elbow Arrow NOTE Be careful not to rest your arm on the air tube This will restrict the flow of air to the cuff TAKING A MEASUREMENT 1 Sit on a chair with your feet flat on the floor Place your arm on a table so the cuff is level with your heart Keep still and do not talk during measurement 2
2. Self diagnosis and treatment using measured results may be dangerous Follow the instructions of your physician or licensed healthcare provider Omron Healthcare recommends you contact your physician if the Heartbeat Symbol 48 flashes on the display with your measurement values 1Canadian Hypertension Education Program 2006 Public Recommendations BATTERY INSTALLATION A CAUTION Use only 1 5V AAA alkaline batteries with this device 1 Press the A indicator on the battery cover and slide the cover off in the direction of the arrow 2 Install 4 AAA size batteries so the positive and negative polarities match the polarities of the battery compartment as indicated NOTE 4 AAA size batteries are not included in this unit 3 Replace the battery cover BATTERY REPLACEMENT xl Low Battery Indicator When the Low Battery Indicator appears on the display turn the monitor off and remove all the batteries Replace with four new batteries at the same time Long life alkaline batteries are recommended A WARNING If battery fluid should get in your eyes immediately rinse with plenty of clean water Contact a physician immediately A CAUTION Dispose of the device components and optional accessories according to applicable local regulations Unlawful disposal may cause environmental pollution APPLYING THE ARM CUFF
3. a a Battery Installation Device error Contact Customer Service TROUBLESHOOTING TIPS No power Replace all four batteries with new ones No display appears on the unit Check the battery installation for proper placement of the battery polarities Blood pressure varies constantly Many factors including stress time of day how you wrap the cuff may affect your blood pressure Review the sections Before Taking a Measurement and Taking a Measurement Measurement values appear too high or too low FCC STATEMENT Note POTENTIAL FOR RADIO TELEVISION INTERFERENCE for U S A only This product has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation The product generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If the product does cause harmful interference to radio or television reception which can be determined by turning the product on and off the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separ
4. OMRON INSTRUCTION MANUAL Automatic Blood Pressure Monitor Model BP710CAN 5328169 3A INTRODUCTION Thank you for purchasing the OMRON BP710CAN IntelliSense Automatic Blood Pressure Monitor Fill in for future reference DATE PURCHASED SERIAL NUMBER Staple your purchase receipt here Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement This means the monitor detects your blood s movement through your brachial artery and converts the movements into a digital reading An oscillometric monitor does not need a stethoscope so the monitor is simple to use The BP710CAN comes with the following components e Monitor Standard Adult Arm Cuff e Instruction Manual printed in English and French Quick Start Guide The BP710CAN IntelliSense Automatic Inflation Blood Pressure Monitor is intended for home use SAVE THESE INSTRUCTIONS SAFETY INFORMATION To assure the correct use of the product basic safety measures should always be followed including the warnings and cautions listed in this instruction manual SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL Indicates a potentially hazardous situation which if not avoided A WARNING could result in death or serious injury Indicates a potentially hazardous situation which if not avoided A CAUTION may result in minor or moderate injury to the user or patient or damage to the equipment or other
5. Press the START STOP button All symbols appear on the display The cuff starts to inflate automatically As the cuff inflates the monitor automatically determines your ideal inflation level Remain still and do not move your arm until the entire measurement process is completed PULSE min NOTE To stop the inflation or measurement push the START STOP button The monitor will stop inflating start deflating and will turn off 3 Inflation stops automatically and the measurement is started As the cuff deflates decreasing numbers appear on the display and the Heartbeat Symbol 48 flashes IZ J Jc a x 4 When the measurement is complete the arm cuff completely deflates Your blood pressure and pulse rate are displayed 5 Press the START STOP button to turn the monitor off NOTE The monitor will automatically turn off after five minutes SPECIAL CONDITIONS A CAUTION Inflating to a higher pressure than necessary may result in bruising where the cuff is applied If your systolic pressure is known to be more than 220 mmHg press and hold the START STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure Da JE mmo T a Dl p 8 x min L Q Co NOTES e Do not apply more pressure than necessary e The monitor will not inflate above 299 mmHg When the measurement is complete the arm cuff completely deflates Your blood pressure and
6. R CUSTOMER SERVICE Visit our web site at www omronhealthcare com Call toll free 1 800 634 4350 SPECIFICATIONS Model BP710CAN HEM 7113 CAN Display LCD Digital Display Measurement Range Pressure 0 to 299 mmHg Pulse 40 to 180 min Accuracy Calibration Pressure 3mmHg or 2 of reading Pulse 5 of reading Inflation Automatic by electric pump Deflation Automatic pressure release valve Rapid Air Release Automatic exhaust valve Pressure Detection Capacitive pressure sensor Measurement Method Oscillometric method Pulse Wave Detection Capacitance type pressure sensor 1 5V 4 AAA batteries Battery Life Approx 300 uses with 4 new alkaline batteries Operating Temperature 50 F to 104 F 10 C to 40 C 15 to 90 RH Humidity Storage Temperature 4 F to 140 F 20 C to 60 C 10 to 95 RH Humidity Air Pressure 700 1060 hPa Main Unit Weight Approximately 8 5 8 oz 245g not including batteries Main Unit Dimensions Approx 5 1 x 4 1 8 w x 2 1 2 b 128 mm x 104 mm x 64 mm Power Source Cuff Size Approximately 5 3 4 w x 17 1 2 1 146 mm x 446 mm Cuff tube 23 5 8 600 mm Cuff Circumference Fits arm circumferences 9 to 13 220 mm to 320 mm Memory Up to 14 readings Contents Main Unit Standard Adult Arm Cuff Instruction Manual and Quick Start Guide Optional Accessories Large Cuff 13 17 320 mm to 420 mm e Type B NOTE These specifications are subject to change without
7. ation between the product and the receiver e Connect the product into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Cet appareil num rique respecte les limites de bruits radioel ctriques applicables aux appareils num riques de Clase B prescrites dans la norme sur le materiel brouilleur Appareils Num riques ICES 003 dict e par le minister des communications Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment WARRANTY INFORMATION LIMITED WARRANTIES Your BP710CAN IntelliSense Automatic Blood Pressure Monitor excluding the arm cuff is warranted to be free from defects in materials and workmanship appearing within 2 years from the date of purchase when used in accordance with the instructions provided with the monitor The arm cuff is warranted to be free from defects in materials and workmanship appearing within one year from the date of purchase when the monitor is used in accordance with the instructions provided w
8. ith the monitor The above warranties extend only to the original retail purchaser We will at our option repair or replace without charge any monitor or arm cuff covered by the above warranties Repair or replacement is our only responsibility and your only remedy under the above warranties To obtain warranty service contact Customer Service by calling 1 800 634 4350 for the address of the repair location and the return shipping and handling fee Enclose the Proof of Purchase Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in transit Because of possible loss in transit we recommend insuring the product with return receipt requested ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THE APPLICABLE WRITTEN WARRANTY ABOVE Some provinces do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER INCIDENTAL CONSEQUENTIAL OR INDIRECT COSTS EXPENSES OR DAMAGES Some provinces do not allow the exclusion or limitation of incidental or consequential damages so the above exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which may vary from province to province FO
9. l C ma E displays with your measurement results pulee i i i we recommend you consult your physician Follow the directions of your Blood AINSI _SJ IJ pressure doctor HEARTBEAT SYMBOL HYPERTENSION INDICATOR 49 TAKING A MEASUREMENT The Heartbeat Symbol 48 flashes on the display during the measurement The Heartbeat Symbol 40 flashes at every heartbeat When the measurement is complete the Heartbeat Symbol 4 flashes on the display with your blood pressure and pulse rate if the reading is above 135 for the Systolic Blood Pressure value and or above 85 for the Diastolic Blood Pressure value USING THE MEMORY FUNCTION The Heartbeat Symbol 48 flashes when the blood pressure reading stored in the memory is above 135 for the Systolic Blood Pressure value and or above 85 for the Diastolic Blood Pressure value The Canadian Hypertension Society CHS recommends the following guideline for upper limit of normal for home blood pressure readings CHS Home Guideline for Upper Limit of Normal BP 135 mmHg 85 mmHg This is a general guideline because blood pressure depends on age and morbidity The CHS recommends a lower home blood pressure goal for certain patients including people with diabetes or kidney disease Systolic Blood Pressure Diastolic Blood Pressure A WARNING The monitor is not intended to be a diagnostic device A WARNING Contact your physician for specific information about your blood pressure
10. ment does not provide an accurate indication of your true blood pressure You need to take and record several readings over a period of time Try to measure your blood pressure at the same time each day for consistency A BW N aD KNOW YOUR UNIT Main Unit Display N Battery compartment BING START STOP seat Memory M button Air jack Components ae gt Ai soaaninonor Z gt GETTING A N Air tube E GETTING ii Te A a Air plug Standard Adult Arm Cuff Instruction Quick Start Manual Guide UNIT DISPLAY Systolic blood pressure al 4 ny E a N k il K l EE Jt m D lt cm a Diastolic blood pressure Memory symbol Heartbeat symbol Displayed when viewing values stored in memory aaa Of is a GUD SB K eo a Lt _ Pulse display PIIL Deflation symbol Irregular Heartbeat symbol Battery low indicator DISPLAY SYMBOLS IRREGULAR HEARTBEAT SYMBOL Q When the monitor detects an irregular rhythm two or more times during the measurement the Irregular Heartbeat Symbol will appear on the display with the measurement values wt P An irregular heartbeat rhythm is defined as a rhythm that is more than 25 slower or 25 faster from the average rhythm detected while the monitor is Normal Heartbeat measuring the systolic and diastolic pressure blood pressure If the irregular heartbeat symbo
11. ne batteries with this device Do not use other types of batteries This may damage the unit CARE AND MAINTENANCE A Do not subject the monitor to strong shocks such as dropping the unit on the floor A Do not submerge the device or any of the components in water A Store the device and the components in a clean safe location A Changes or modification not approved by the manufacturer will void the user warranty Do not disassemble or attempt to repair the unit or components BEFORE TAKING A MEASUREMENT To ensure a reliable reading follow these recommendations 1 Avoid eating drinking alcohol smoking exercising and bathing for 30 minutes before taking a measurement Rest for at least 15 minutes before taking the measurement Stress raises blood pressure Avoid taking measurements during stressful times Measurements should be taken in a quiet place Remove tight fitting clothing from your left arm Sit on a chair with your feet flat on the floor Rest your left arm on table so that the cuff is at the same level as your heart Remain still and do not talk during the measurement Wait 2 3 minutes between measurements The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement You may need to increase the wait time depending on your individual physiological characteristics 8 Keep a record of your blood pressure and pulse readings for your physician A single measure
12. not use any abrasive or volatile cleaners Do not attempt to clean the cuff A CAUTION Do not submerge the device or any of the components in water Do not subject the monitor to extreme hot or cold temperatures humidity or direct sunlight A CAUTION Store the device and the components in a clean safe location A CAUTION Do not subject the monitor to strong shocks such as dropping the unit on the floor Remove the batteries if the unit will not be used for three months or longer Always replace all the batteries with new ones at the same time Use the unit consistent with the instruction provided in this manual Use only authorized parts and accessories Use the unit in a manner consistent with the instructions provided in this manual A CAUTION Use only Omron authorized parts and accessories Parts and accessories not approved for use with the device may damage the unit A CAUTION Changes or modification not approved by the manufacturer will void the user warranty Do not disassemble or attempt to repair the unit or components ERROR INDICATORS SYMBOL CAUSE CORRECTION Take another measurement and remain still until the measurement is complete Monitor could not detect pulse wave Cuff under inflated Cuff not applied Remove the arm cuff correctly Read Taking a Measurement E Cuff over inflated Wait 2 3 minutes Take another measurement Replace the four batteries Refer to Batteries are worn
13. notice OMRON HEALTHCARE INC 1200 Lakeside Drive Bannockburn Illinois 60015 www omronhealthcare com Copyright 2009 Omron Healthcare Inc Made in China
14. property OPERATING THE DEVICE A Contact your physician for specific information about your blood pressure Self diagnosis and treatment using measured results may be dangerous Follow the instructions of your physician or licensed healthcare provider A The monitor is not intended to be a diagnostic device A If battery fluid should get in your eyes immediately rinse with plenty of clean water Contact a physician immediately A Read all of the information in the instruction manual and any other literature in the box before operating the unit A This device is intended for use in measuring blood pressure and pulse rate in the adult population Do not use this device on infants or persons who cannot express their intentions A Read the Special Conditions section of the instruction manual if your systolic pressure is known to be more than 220 mmHg Inflating to a higher pressure than necessary may result in bruising where the cuff is applied A Operate the device only as intended Do not use the device for any other purpose A Dispose of the device components and optional accessories according to applicable local regulations Unlawful disposal may cause environmental pollution A Do not use a cellular phone near the device It may result in an operational failure A Use only Omron authorized parts and accessories Parts and accessories not approved for use with the device may damage the unit A Use only 1 5 V AAA alkali
15. pulse rate are displayed USING THE MEMORY FUNCTION Every time you complete a measurement the monitor stores the blood pressure and pulse rate in the memory The monitor automatically stores up to 14 sets of measurement values systolic pressure diastolic pressure and pulse rate When 14 sets of measurement values are stored the oldest record is deleted to save the most recent values 1 Press the Memory M button The most recent set of measurement values appears on the display The values are displayed from the most recent to the oldest NOTE The number of the reading stored in the memory appears for a second before the pulse rate is displayed The newest set is numbered 1 2 Press the START STOP button to turn the unit off TO DELETE ALL THE VALUES STORED IN MEMORY You cannot partially delete values stored in the memory All values will be deleted 1 Press the Memory M button Then while holding it down press the START STOP button down for more than 2 seconds until the display appears as illustrated below a V 2 Press the START STOP button to turn the unit off NOTE The monitor will automatically turn off after five minutes CARE AND MAINTENANCE To keep your digital blood pressure monitor in the best condition and protect the unit from damage follow the directions listed below Do not forcefully bend the arm cuff or air tube Do not fold tightly Clean the monitor with a soft dry cloth Do