Home

INSTALLATION AND OPERATING INSTRUCTIONS FOR Built

image

Contents

1. dry location Figure 1 Figure 2 Figure 3 Figure 4 FIREPLACE INSTALLATION BUILT IN BUILT IN A A CAUTION ul De Figure 5 Two people may be needed to per R form this installation 1 Prepare a wall with a framed opening to accomodate the size of your unit Figure 5 h WARNING Ensure that the Main ON OFF Switch is set to the OFF Position page 16 and that the circuit on which the fireplace is to be in stalled on has the power cut off at the service panel until instal lation is complete h WARNING Do not attempt to wire your own new outlets or circuits To reduce the risk of injury elec tric shock or fire use a licensed electrician 10 FIREPLACE INSTALLATION BUILT IN 38 N NOTE BEFORE YOU INSTALL 1 Lift fireplace and insert into opening Ad just the unit to achieve the desired amount of depth Figure 6 e For Glass front Models Units must stick out of the wall a minimum of 2 or 5 cm 2 Make sure that the power supply port is not behind the wall e For Stone and Steel front Models Units must stick out of the wall a 3 Level the fireplace minimum of 2 3 4 or 7 cm ee 4 Drive mounting screws into the mount ing brackets nailing flanges on the unit and the wall studs Figure 7 Figure 6 Mounting Bracket Power adaptor port Fire Glass Media Tray Figure 7 Power adaptor port 11 A FIRE
2. long an implied warranty lasts so the above limitation may not apply to the purchaser All other warranties expressed or implied with respect to the product its components and accessories or any obligation liabili ties on the part of Amantii are hereby expressly excluded Limitations to Coverage Under Limited Warranty This limited warranty does not apply to products that have been repaired except by Amantii or its authorized service representa tives or otherwise altered This limited warranty further does not apply to defects resulting from misuse abuse accident neglect incorrect installation improper maintenance or handling or operation with an incorrect power source Products made by other manufacturers sold with the product or thereafter are not covered by this limited warranty The use of unauthorized components will render this warranty null and void Service Under Limited Warranty Defects must be brought to the attention of Amantii Technical Service by contacting Amantii at 1 888 406 8764 or at 1503 7088 18th Avenue Burnaby British Columbia Canada V3N OA2 Please have your proof of purchase catalogue model and serial num bers available when calling any and all service under the limited warranty requires a proof of purchase of the product Defects Should a product or part covered by this limited warranty be proven to be defective in material or workmanship and during the one 1 year limited warranty period
3. recommended that two people install Figure 13 the front onto the appliance wear safety glasses and gloves when handling glass 1 Lift fireplace front Figure 13 and line up the brackets with the four 4 shoulder screws on the side of the appliance body Figure 14 or Figure 15 2 Attach the front to the unit Figure 14 Figure 15 Unit Unit Mounting bracket Shoulder Screw Shoulder Screw Wall Wall Built In Installation Wall Mount Installation 14 OPERATING THE UNIT GETTING POWER TO THE UNIT 1 Make sure the appliance is switched OFF refer to page 16 for instruction 2 Attach the provided adaptor to the power port on the right hand side of the unit Figure 16 3 Plug unit into electrical outlet WARNING Do not attempt to wire your own new outlets or circuits To reduce the risk of injury electric shock or fire use a licensed electrician Figure 16 Power adaptor port Wall 15 OPERATING THE UNIT CONTROLLING THE FIREPLACE Figure 17 BUTTONS AND INDICATORS There are three 3 buttons on the remote controller Figure 14 and three 3 on the control panel of the fireplace each pair of buttons with the same label perform the same function There are three buttons on the remote control Figure 17 lt ON OFF gt button controls the power to the appliance lt DIMMER gt button is used to adjust the brightness of simulated flames FLAME button is used to adjust the sp
4. Amantii will replace such defective product or part without charge If Amantii is unable to replace such product or if replacement is not commercially practicable or cannot be timely done in its sole discretion Amantii may in lieu of replacement choose to refund the purchase price for such product or part Limitations In no event will Amantii including without limitation any of its directors officers shareholders employees consultants agents heirs executors administrators and assigns be liable to the purchaser or any third party whether in contract in tort or on any other basis for any indirect special punitive exemplary consequential or incidental loss cost or damage arising out of or in con nection with the sale maintenance use or inability to use the product even if Amantii including without limitation any of its direc tors officers shareholders employees consultants agents heirs executors administrators and assigns have been advised of the possibility of such losses costs or damages or if such losses costs or damages are foreseeable In no event will Amantii including without limitation any of its directors officers shareholders employees consultants agents heirs executors administrators and assigns be liable for any direct losses costs or damages that exceed the purchase price of the product Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above
5. PLACE INSTALLATION WALL MOUNT Figure 8 NOTE BEFORE YOU INSTALL WEM It is strongly recommended that the screws RUBRI NE be screwed into the wall studs where pos sible If the wall studs cannot be used ensure that plastic anchors are used Stakes for hanging 1 Affix the provided mounting bracket to the wall Figure 8 P Height from floor e Make sure it is level 2 Lift fireplace unit and insert the stakes for hanging into the keyholes on the back Floor of the unit Figure 9 Figure 10 3 Check the appliance for stability ensur ing that the appliance will not pull free from the wall Figure 9 Figure 10 Stakes for hanging Wall Back of unit o Side view 12 FIRE GLASS MEDIA INSTALLATION N NOTE BEFORE YOU INSTALL CLEANING THE MEDIA The media may contain a fine white dust that needs to be cleaned prior to installation Clean the media with soap drain rinse thoroughly and dry before placing into the tray 1 Choose the colour of Fire Glass Media you would like to use Figure 11 2 Place the Fire Glass Media into the Tray Figure 12 Built In installation shown Fire Glass Media installation is the same for both Built in and Wall Mount installation methods e t is not necessary to use all the media supplied Figure 12 Fire Glass Media Tray Figure 11 Hz 01 Clear Hz 32 Aqua A 13 FRONT INSTALLATION N NOTE BEFORE YOU INSTALL It is
6. VA ELECTRIC FIREPLACES INSTALLATION AND OPERATING INSTRUCTIONS FOR BUILT IN UNITS BLT IN 38 BLT IN 58 BLT IN 36 amp BLT IN 62 C El US Listed Intertek INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE BLT IN 36 SPECIFICATIONS l dance with the ETL Intertek Standards for fixed and location dedicated electric room appliances in the United States and Cana da If you need assistance during installa tion please contact your local dealer NOTE This appliance must be electrically local codes In the absence of local codes us the current CSA C22 1 Canadian Elec trical Code in Canada or the ANSI NFPA 70 National Electrical Code in the United States 36 indi 758 20 11 16 758 711 16 26 1 2 26 1 2 10 1 2 1 8 8 5 16 C ell US LISTED Intertek 247 16 INSTALLATION OVERVIEW SITE SELECTION Review and consider all of the following conditions for installation e Dimensions of the unit e Unit requires a minimum of two 2 wall studs in order to ensure a secure installation Two possible installation methods e Built In page 10 e Wall Mount Page 12 WARNING Ensure the power cord is not in stalled so that it is pinched or against a sharp edge and ensure that the power cord is stored or se cured to avoid tripping or snagging to reduce the ris
7. eed of the motor There are three indicators on the control panel 5 is the power indicator it lights up when the fireplace is working and turns out when the fireplace is off indicates the status of the simulated flame It lights up when the flame simula tor component is working and will be flash ing when you adjust the flame y SC indicates the speed of the motor It lights up when the flame simulator compo nent is working and will be flashing when you adjust the speed of the motor The red window on the control panel of the fireplace is the eye of the receiver do not cover Do not leave unit on and unattended 16 FIREPLACE MAINTENANCE h WARNING Disconnect power before performing any maintenance or cleaning to reduce the risk of fire electric shock or damage LED LIGHT BULB REPLACEMENT LED light bulbs are to be replaced by the manufacturer it s service agent or similar quali fied person in order to avoid hazard h WARNING Allow at least 5 minutes for LED bulbs to cool off before handling bulbs to avoid burns LED LIGHT BULB REQUIREMENTS Rating Voltage 12 Volts Rating Power 5 Watts BLT IN 38 3 Bulbs BLT IN 58 5 Bulbs BLT IN 36 3 Bulbs BLT IN 62 5 Bulbs A CAUTION Do not exceed 5 watts per bulb UNIT DISPOSAL Do not dispose with other household wastes To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly
8. k of fire electric shock or injury to persons Construction and electrical out let wiring must comply with local building codes and other applica ble regulations to reduce the risk of fire electric shock and injury to persons 38 e N NOTE BEFORE YOU INSTALL A 15 Amp 120 Volt circuit is required A dedicated circuit is preferred but not essential in all cases 1 Select a location that is not suscep tible to moisture dust and is away from high traffic locations and things that many catch fire or block openings such as drapes pillows furniture etc 2 If possible select a location near an existing electrical outlet for ease of electrical hook up 3 Remove fireplace front fireglass media and all hardware from box and remove all packaging related materials prior to installation Figures 1 2 3 4 4 Plug in the unit to ensure the LED lights are working correctly See page 15 5 Store the fireplace in a safe dry and dust free location until you are ready to install the fireplace ADDITIONAL HARDWARE MAY BE REQUIRED e Wall Mount Method Approx Twelve 12 6 Wood screws e Built In and Wall Mount Methods Plastic wall anchors where studs are not available INSTALLATION OVERVIEW Locate fire glass media and set aside for later installation See Page 13 Remove sides of box Remove packaging surrounding the unit and front Discard packaging materials and store fireplace in a safe
9. limitation or exclu sion may not apply to the purchaser Application of Provincial and State Law This limited warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction The provisions of the United Nations Convention on Contracts for the Sale of Goods shall not apply to this limited warranty or the sale of products covered by this limited warranty General Amantii reserves the right to make changes at any time without notice in design material specifications prices and the right to discontinue styles and products Amantii ELECTRIC FIREPLACES WWW amantii com Date of Purchase Dealer Information
10. to promote the sustainable reuse of material resources Contact your local landfill for appropriate disposal instruction 17 WARRANTY Amantii Imports Corp Amantii warrants that your newly purchased Amantii electric fireplace is free from manufacturing and material defects for a period of one 1 year from the date of the first purchase subject to the conditions and limitations contained below Warranty Application amp Exclusions This limited warranty applies to your newly purchased Amantii electric fireplace the limited warranty s application is limited to purchases made in any province of Canada or in any of the 52 States of the United States of America including the District of Co lumbia Only the original purchaser of the product is eligible for coverage under this limited warranty the warranty is not transfer able Light bulbs are not covered by this limited warranty and are the sole responsibility of the owner purchaser Warranty Coverage and Term Products covered by this limited warranty have been tested and inspected prior to shipment and subject to the provisions of this warranty Amantii warrants such products to be free from defects in material and workmanship for a period of one 1 year from the date of the first purchase of such products The limited one 1 year warranty period for products also applies to any implied warranties that may exist under applicable law Some jurisdictions do not allow limitations on how

Download Pdf Manuals

image

Related Search

Related Contents

PHYGROW - Center for Natural Resource Information Technology  PCF50633  MTG-108 取扱説明書  IT systems for SMEs 500 to 2000 VA  2008.7 - VAIO  Bedienungsanleitung - Psn  KOHLER K-CB-CLC2026FS Instructions / Assembly  Kingston Technology 4GB microSDHC  UMC800 Control Builder Funktionsblock  KX-FKN518 - Panasonic  