1. Thermocouple block Tip over switch 3 While the heater unit does not require a filter the unit must be kept clean and the burner and pilot assembly must be kept free of dust and dirt to ensure optimal and safe operation at all times Store the unit in a clean environment and make sure that the unit is leak checked and cleaned before every use Do not clean the unit with volatile substances see maintenance on Page 3 PARTS LIST 2009 2010 FRHR 100N P RADIANT CONSTRUCTION HEATERS FRHP A OSRNG Burner Orifice NG FRHP O7RLP Burner Assembly LP FRHP O7RNG Burner Assembly NG FRHP 21 El Compression Nut amp Sleeve for Pilot 2009 1 FRHR 100 Parts List flagro INDUSTRIES HP LIMITED FRHR 100 Parts List INDUSTRIES ro E ae nen FRHR 100 Parts List flagro Ak LIMITED FRHR 100 Parts List flagro S IP LIMITED INDUSTRIE b c FRHR 100 Parts List Accessories HOSES Item Description P N Removable Screen Assy FRHP 12 FRHP 08R FHRP 10 49 6C Gas Control Valve FRHP 01 LP NG Green Control Knob Black Knob FRHP 23 FRHP 19 FRHP 03A 122 CD 100 506 122 DC 100 506 MANIFOLDS 48 6C Propane Burner Assy FRHP 07RLP ___ Natural Gas Burner Assy FRHP 07RNG 46 6C FRHP 09 FRHP 04A Main Burner Orifice NG___ FRHP 05RNG Main Burner Orifice LP___ FRHP 05RLP T 18 24 Not shown 26 Not shown Pilot Assembl
2. OPERATING INSTRUCTIONS MANUAL Please retain for future reference For FRHR 100N P RADIANT CONSTRUCTION HEATERS i F W a X hh AN XY 1 Li y h n l Pam E Wi Wi Pe Wi ON i t a CERTIFIED FOR USE IN CANADA AND U S A As per Standard ANSI Z83 7 2000 CSA 2 14 2000 Gas Fired Construction Heaters Unvented Unattended Type TER TE Fa CV us e 9 Nock He FLAGRO INDUSTRIES LIMITED ST CATHARINES ONTARIO CANADA GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRICAL SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNER DUST PARTICLES OR UNKNOWN CHEMICALS WARNING NOT FOR HOME OR RECREATIONAL VEHICLE USE This heater is designed and approved for use
3. as a construction heater under ANSI Z83 7 2000 and CSA 2 14 2000 Gas Fired Construction Heaters We cannot anticipate every use which may be made of our heaters CHECK WITH YOU LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS Other standards govern the use of fuel gases and heat producing products in specific applications Your local authority can advise you about these E WARNING INTENDED USE IS PRIMARILY THE TEMPORARY HEATING OF BUILDINGS UNDER CONSTRUCTION ALTERATION REPAIR OR EMERGENCIES ONLY ALWAYS PROVIDE ADEQUATE VENTILATION 1 SQ IN OF FRESH AIR MUST BE SUPPLIED FOR EVERY 1000 BTUH OF HEAT THIS HEATER SHALL BE INSTALLED SUCH THAT IT IS NOT DIRECTLY EXPOSED TO WATER SPRAY RAIN AND OR DRIPPING WATER MINIMUM CLEARANCE TO COMBUSTIBLES TOP 48 inches SIDES 30 inches BOTTOM 0 inches INLET PRESSURES FRHR 100N Natural gas MINIMUM Supply Pressure 7 W C MAXIMUM Supply Pressure 14 W C FRHR 100P PQD Propane MINIMUM Supply Pressure 11 W C MAXIMUM Supply Pressure 14 W C MAINTENANCE 1 This construction heater should be inspected before each use All burner ports should remain clear and the valve should be inspected for any possible damage The heater should be test fired before each use High pressure air may be used to blow out the inside of the burner 2 The heater should be inspected annually by a qualified service person 3 The heater must be kept clear and free from combu
4. stible materials gasoline and other flammable vapors and liquids 4 The hose assembly shall be visually inspected prior to each use of the heater If it is evident there is excessive abrasion or wear or the hose is cut it must be replaced prior to the heater being put into operation The replacement hose assembly shall be supplied by Flagro Industries Limited Please see Parts List INSTALLATION All natural gas heaters must be installed by a qualified gas fitter and must conform to local installation codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 and the Natural Gas and Propane Installation Code CSA B149 1 The natural gas heater is provided with a Y2 male quick disconnect fitting The hose assembly used to install this heater must be a Type I CGA AGA approved hose assembly equipped with a 12 female quick disconnect socket to mate with the inlet fitting Before lighting the heater all connections must be leak checked using a soap and water solution The heater must be installed on a level surface FOR A HEATER CONNECTION TO AN LP GAS SUPPLY CYLINDER 1 The installation must conform with local codes or in the absence of local codes with the Standard for the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and the Natural Gas and Propane Installation Code CSA B149 1 Ze The hose assembly used to install this heater must be a Type I CGA AGA approved hose assembly The heater mus
5. t be located at least 20 ft 6 10m from any LP gas cylinder 3 The heater should be installed using a LP gas cylinder with a minimum capacity of 30 Ibs up to a maximum capacity of 100 Ibs 4 The cylinders used to supply this heater must provide for vapor withdrawal only 5 The heater must be connected with a low pressure regulator and POL inlet fitting The POL fitting 1s connected to the LP gas cylinder by turning the POL nut counter clockwise and tightened using a wrench All connections must be checked for leaks using a soap and water solution or approved leak detector solution Use a wrench and turn the POL nut clockwise to disconnect the heater from the cylinder 6 The cylinder must be disconnected from the heater when not in use 7 The heater is to be stored indoors the connection between the LP gas supply cylinder s and the heater must be disconnected and the cylinder s removed from the heater and stored in accordance with Chapter 5 of the Standard for the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and CSA B149 1 Natural Gas and Propane Installation Code LIGHTING INSTRUCTIONS Ensure the heater is connected to the proper source of gas and proper inlet pressures are supplied The heater must be installed by a qualified installer Set thermostat knob green button to high position Rotate the control knob black counter clockwise to PILOT position Depress and hold control knob Light the pilo
6. t burner using a long reach lighter through lighting hole provided Release the knob after 60 seconds Pilot will remain lit Main burner will remain off Turn control knob counterclockwise to ON position Main burner will light If the main burner fails to light turn the control knob clockwise to the OFF position wait 5 minutes and repeat step 3 The green knob controls the thermostat option This will light and extinguish the main burner as the temperature fluctuates A AA TES 34 ypa i L J EP 9 SHUT OFF INSTRUCTIONS 1 Turn the control knob clockwise to the OFF position Both main burner and pilot burners will extinguish 2 Turn off source of fuel IMPORTANT NOTES FOR SUCCESSFUL LIGHTING AND OPERATIONAL SAFETY 1 For safety purposes this heater model is equipped with a tip over switch which will prevent the heater from operating or being lit if it is bumped jarred knocked over or positioned on an angle In order to light and operate properly this heater MUST be placed on a flat horizontal surface in an upright position ee n m VE wt a ra TM i o id fd LA j f A1 M0 x D M n il i D EU CORRECT POSITION INCORRECT POSITION 2 The tip over switch is interlocked with the thermocouple The connections on the thermocouple block must be kept clean and tight at all times to ensure proper operation of these components
7. y LP FRHP 02LP RHP 02NG SOFTPropane Hose FRHP 101600LP FRHP 101 MAN UI MAN U2 WOlLOI mW an MW BRiO Tmo m m i AIw wINI o Enbridge Manifold MAN E1 Enbridge Double Manifold MAN E2 Enbridge Nipple MAN NP Enbridge Meter Key MAN Key