1. 3 Proceed with steps 5 to 12 above 4 Secure gas supply line to wall up to outlet gt Pipe to Protrude to 1 1 8 Seal Piping Pull out Pipe Do NOT fasten riser Clearance Hole OPERATING INSTRUCTIONS 1 Turn off the 1 4 turn shut off valve by moving the valve handle in the direction of the arrow WARNING Do not connect coupler plug N3 that is not properly attached to a a appliance with a connector or grill hose as will escape if plug N3 alone is attached and 4 turn valve is opened 2 Connect gas appliance plug N3 to outlet N1 by sliding outlet socket sleeve away from plug and inserting plug into socket Push plug into socket until sleeve snaps forward to lock the assembly together DISCONNECTING GAS APPLIANCE FROM OUTLET 1 Turn gas control knobs of appliance to off position OFF a 2 Turn gas supply off at the turn shut off valve of gas outlet 3 Disconnect plug N3 by sliding back gas outlet N1 socket sleeve away from the plug and pulling plug out Specifications Retract f Rated flow at 6 w c pressure drop 75 000 B T U Hr Natural Gas 100 000 B T U Hr Propane Sleeve to f Non Maximum working pressure not to exceed 5 P S I G Gas Outlet N1 is equipped with a thermal device which automatically shuts off gas flow when 250 121 C is exceeded Operating Temperature 40 F 40 C to 200 F 93 C Kit Contents D FAIRVIEW FITTINGS amp
2. MFG Hea orrices Form PM INSTAUCF NGO e 449 Attwell Drive Toronto Ontario M9W 5C4 e 2245 Kenmore Avenue Buffalo New York 14207 Tel 416 675 4233 Fax 416 675 9416 Tel 716 874 2490 Fax 716 874 0413 VU Cd rL0 R by Fairview MODE D INSTALLATION ET D EMPLOI DES SORTIES DE GAZ NATUREL PROPANE A L EXTERIEUR INTERIEUR DANGER D FAUT DE SUIVRE LES INSTRUCTIONS CI DESSOUS UNE EXPLOSION OU UN INCENDIE POURRAIT SE DECLARER CAUSANT DES DOMMAGES MATERIELS SERIEUX DES BLESSURES GRAVES OU MEME LA MORT ATTENTION __ SEUL UN MONTEUR D INSTALLATIONS AU GAZ AGR DOIT POSER CETTE SORTIE ET LA ANSI Z21 90 2001 CSA 6 24 2001 Normes ANSI et CSA pour les prises US d alimentation de gaz CONDUITE DE GAZ PERMANENTE RATTACHEE CE DISPOSITIF DOIT ETRE INSTALLE CONFORMEMENT AUX REGLEMENTS MUNICIPAUX OU EN L ABSENCE DE TELS REGLEMENTS SELON LE U S A NATIONAL FUEL GAS CODE NFPA 54 ANSI 2223 1 OU CAN CGA B149 1 OU DU CODE D INSTALLATION DU GAZ NATUREL OU GAZ NATUREL ET GAZ PROPANE DU CODE D INSTALLATION CSA B149 1 S IL Y A LIEU 1 LIRE TOUTES LES INSTRUCTIONS AVANT L INSTALLATION ET L UTILISATION de ce dispositie 2 NE PAS modifier ce dispositif V rifier les raccords S ils sont endommag s les retourner au marchand et changer le tout pour un nouveau dispositif complet 3 Ces instructions s appliquent l utilisation de tuyaux en fer noir pour l alimentation en gaz Cette sortie de gaz peut tre util
3. conduite d alimentation de gaz vers l ext rieur Fig B et installer le raccord 9 Repousser le raccord jusqu ce qu il s embo te dans la base du bo tier 10 Purger et mettre la conduite de gaz en pression V rifier tous les raccords qui n ont pas subi d essai d tanch it auparavant 11 Sceller l ouverture du mur autour de la conduite d alimentation de gaz et du bo tier N2 tel que requis afin d emp cher toute fuite de gaz de p n trer dans le vide int rieur du mur 12 Fixer le couvercle du bo tier et aligner le bouton de commande face au trou sur le couvercle Fig C INSTALLATION SUR LE COTE 1 Installer une conduite d alimentation permanente moins de 24 pouces de l emplacement de la sortie sans fixer la conduite au mur Percer l entr e d fon able sur le boitier N2 Proc der aux tapes 5 12 ci dessus Fixer la conduite d alimentation de gaz au mur jusqu la sortie en Tuyau depassant Montants de 1 a 1 1 8 pouce Vea Mur Sceller les ouvertures Tirer la conduite vers l exterieur 24 pouces NE PAS fixer minimum la colonne montante Trou de passage MODE D EMPLOI 1 Fermer la soupape d arr t 1 4 de tour en d pla ant le bouton de commande dans le sens de la fl che ATTENTION Ne pas brancher le raccord de s ret N3 s il n est pas correctement fix a un appareil gaz muni d un raccord ou d un tuyau Le gaz s chappera si seul le raccord de s ret N3 est fix e
4. in the wall Gas supply line must be able to move freely during outlet installation 5 Pressure test the permanent gas line to outlet in accordance with all applicable codes and regulations 6 Place enclosure N2 over pipe Align valve connection N1 with gas supply line ensuring valve handle will protrude properly through outlet cover Mark screw holes Fasten base to wall Fig B using 10 x 2 wood screws on stud side and standard wall screws with anchors on cavity side 3 16 x 2 4 self tapping concrete anchors on outdoor installations Note equivalent strength fasteners can be used at gas fitter s determination AVOID OVER TIGHTENING OF FASTENERS TO PREVENT DAMAGE TO ENCLOSURE 7 If required cut spacers from rigid tube N4 provided and install mounting screws through spacer holes 8 Remove valve from mounting bracket pull out Gas supply line Fig B and install valve 9 Push back valve until it snaps into enclosure base mounting bracket 10 Purge and pressurize gas line checking all connections not previously leak tested 11 ean np Opening around gas supply line and the enclosure N2 as required to prevent any leaking gas from entering the wall cavity 12 Attach enclosure cover aligning valve handle with cover hole Fig C FOR SIDE MOUNTING INSTALLATION 1 Install a permanent gas line to outlet location leaving line unsecured to wall within 24 of outlet location 2 Remove appropriate enclosure punch out see N2
5. 716 874 2490 Fax 716 874 0413
6. A U ay C43 rLO C by Fairview INSTALLATION amp OPERATING INSTRUCTIONS FOR NATURAL GAS PROPANE INDOOR OQUTDOOR APPLIANCE OUTLET DANGER FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN AN POR DEATH Qu FIRE THAT MAY CAUSE PROPERTY DAMAGE SERIOUS INJURY OR DEATH ANSI Z21 90 2001 De CSA 6 24 2001 American National Standard CSA Standard US for Gas Convenience Outlets CAUTION YOU MUST BE A QUALIFIED GAS FITTER TO INSTALL THIS OUTLET ASSEMBLY AND THE PERMANENT GAS LINE THAT ATTACHES TO IT THIS DEVICE SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES IN ACCORDANCE WITH U S A NATIONAL FUEL GAS CODE NFPA 54 ANSI Z223 1 OR NATURAL GAS AND PROPANE INSTALLATION CODE CSA B149 1 AS APPLICABLE 7 1 READ ALL INSTRUCTIONS PRIOR TO INSTALLATION AND USE of this outlet assembly 2 DO NOT make modifications to this outlet assembly Examine fittings for damage If damaged return to place of purchase and exchange for a complete new outlet assembly 3 These instructions are based on the use of black iron gas supply piping This gas outlet can be used with all approved gas piping systems however the gas outlet must be securely mounted to the building or structure This mounting may rely on the enclosure or on the piping system if said enclosure or piping system is sufficiently strong and secure for the purpose 4 Install a permanent gas line as per Fig A Note DO NOT fasten the riser or elbow
7. is e avec tout type de tuyauterie de gaz cependant la sortie de gaz doit tre fix e solidement au mur ou la structure Le dispositif peut tre fix sur l enceinte ou le syst me de tuyauterie si ces derniers sont suffisamment robuste et s curitaire pour cet usage 4 Installer une conduite de gaz permanente tel qu illustr a la Figure A Note NE PAS fixer la colonne montante ou le coude au mur La conduite d alimentation doit pouvoir bouger librement pendant l installation de la sortie 5 Effectuer une preuve de pression sur la conduite de gaz permanente conform ment tous les codes et r glements applicables 6 Placer le bo tier N2 par dessus le tuyau Aligner le raccord N1 avec la conduite d alimentation de gaz et s assurer que le bouton de commande d passe suffisamment le trou du bo tier Marquer les trous de vis Fixer le bo tier au mur Fig B l aide de dix 10 vis bois de 2 1 2 pouces sur le montant et de vis standard avec ancrage dans le vide int rieur du mur vis d ancrage b ton autotaraudeuse de 3 16 x 2 1 4 pour les installations ext rieures Note des vis d assemblage de force quivalente peuvent tre utilis es selon le jugement de l installateur NE PAS TROP SERRER LES VIS POUR NE PAS ENDOMMAGER LE BOITIER 7 S il y a lieu couper les carteurs du tuyau rigide N4 fourni et installer les vis a travers les trous situ s sur l carteur 8 Retirer le raccord du support de fixation puis tirer la
8. t la soupape d arr t 1 4 de tour est ouverte 2 Poser le raccord de s ret N3 sur la sortie N1 en faisant glisser le manchon sur le raccord de sortie vers l arri re et en poussant le raccord vers l avant Pousser le raccord jusqu ce que le manchon s emboite vers l avant pour verrouiller I S E parties ensemble DEBRANCHEMENT DE L APPAREIL A GAZ DE LA SORTIE an i 1 Placer le bouton de commande du gaz la position OFF 2 Couper l alimentation du gaz la soupape d arr t 1 4 de tour de la sortie de gaz 3 D brancher le raccord de s ret N3 en faisant glisser le manchon sur le raccord de sortie N1 vers l arri re et en tirant sur le raccord de s ret Fiche technique douille pour D bit nominal 6 po de chute de pression de la colonne d eau 75 000 Btu h gaz naturel 100 000 d brancher propane La pression de service maximale ne doit pas d passer 5 psig Le boitier est pourvu d un dispositif lequel ferme automatiquement le debit de gaz lorsque la temp rature atteint 250 F 121 C Temp rature d op ration 40 F 40 C 200 F 93 C Contenu NA d une trousse z Entr e d fon able Sortie de gaz Couvercle de la sortie Bouchon de l appareil Tube s parateur g FAIRVIEW FITTINGS amp MFG Hean orrices Fmuare nsraucracoe 449 Attwell Drive Toronto Ontario M9W 5C4 e 2245 Kenmore Avenue Buffalo New York 14207 Tel 416 675 4233 Fax 416 675 9416 Tel