        Operating Instructions for the ESL20 Electronic Safe Lock Contents
         Contents
1.    1 3 Dual Control  This feature provides for a higher level of security  where two different  combinations are required to open the safe  When set  the lock requires that two users  key their individual combinations  one after the other  before the lock will open  After the  first user keys a valid combination  a short warbling tone is sounded  and the second user    Document Part No  4305149  Revision C 18 Sept  2000    14    1 5    1 6    1 7    2 1    2 2    2 3    ALNGEMGAall OGCULILY FIUUULL UYU     is then required to key a valid code  If no second code is keyed within 10 seconds  the  lock goes to the resting condition and the process must be started again     Armored Car Time Delay Bypass  This feature allows Time Delay to be used under  normal access situations  but provides a means to bypass time delay when cash handling  methods require that an Armored Car courier can take deposits without waiting for the  delayed access  It still requires that a valid resident User be present to open the safe   The Armored Car Code  User 9  can be keyed in first  followed by a valid user code or   the Armored Car Code can be used during the Delay Period to stop the delay and then  the user can open the lock with a valid code     Duress Alarm  This feature requires that one of the optional Expansion Modules   ESL20EXP1  ESL20EXP2 or ESL20EXP3  be attached to provide electrical connection  to external systems like alarms and monitoring services  The feature allows a user to  secre
2.  Bypass   C   41       Master Code        0      5 6 External Control  Function 50   5 6 1 To Enable External Control   C     50        Master Code        1      5 6 2 To Disable External Control   C       50       Master Code     0    5 6 Subordinate User Combo Change  Function 60   5 6 1 To Enable Subordinate User Combo Change   C       60       Master Code     1    5 6 2 To Disable Subordinate User Combo Change   C       60       Master Code     0    5 7 Reset All Functions  Function 99   5 6 1 To Reset All Functions     C       99        Master Code     1    6 Mixed Operating Modes    Any combination of modes can be active at the same time  Here are some situations that are  possible and how they interact together     6 1 Dual Combo and Time Delay  Any one valid combo can start the Time Delay  but after the  Delay Period  two different valid combo   s are necessary to cause lock opening     6 2 Armored Car Code  Dual Combo and Time Delay  Armored Car TDL Bypass only allows the  bypassing of Time Delay  Two valid User codes are still necessary to open the lock even the  when Armored Car Code is used to bypass Time Delay     6 3 Duress Alarm output will be caused any time the Duress code is entered by any User during  opening or starting of Time Delay  Requires Expansion Module     6 4 Enabling Dual Combo Mode automatically adds a User 1  even if Multi User Mode is disabled   Don   t forget to set a Code for User 1 or there will not be two codes to open the lock     Documen
3.  a Delay Period of  1 to 99 minutes  If a user keys in a valid combination  a flashing of the LED lamp  approximately 2 times per second indicates the Delay Period  At the end of the Delay  Period  a long warbling tone is sounded to indicate the completion of the delay  An Open  Period begins timing after the completion of the Delay Period and is indicated by 4 beeps  and LED flashes every five seconds  During this period  the user must key a combination  and cause the lock to open  The open period can be set for 1 to 9 minutes long  Time  Delay can be canceled during the delay period by pressing    C      any number key             1 2 Multiple Users  Many cash handling methods require that several people have access to the  safe  With an electronic lock in multi user mode  there is no need for all users to share  the same combination  as is the case with a mechanical combination lock  This feature  also allows the supervisor the ability to control the subordinate users individually and  makes employee turnover easier to manage because individual users can be added and  deleted at will without affecting others  A    Poor Man   s Time Lock    effect can be  implemented daily where the Master User can disable the Multi User Mode at the end of  the day and then re enable the mode at the beginning of the next business day  This  causes the lock to reject all the Subordinate User Codes during off business hours  The  individual subordinate user codes are not lost  just disabled  
4.  when there have been no changes or after a Function Reset  F99  has been executed   They are as follows     Function Code List Enable 1  Disable 0    Setting  Function   Function Description Range Default      01   Time Delay Mode Enable Disable   tor   0      External Control Port Enable Disable    60   Subordinate User Combo Change Enable Disable    99   Reset All Functions to Default settings       AGNA OGCULILY FIUUULL UYU     A function is set in the following standard format     C        2 Digit Function Code         Master User Code         Function Setting        TsecT Tsact Tsact TLGCT  After each          a Short Good Combo Tone  SGCT  will be given  until the last         of the sequence is  pressed  at which time it gives a Long Good Combo Tone  LGCT  indicating the successful setting  of a function  Any time during the sequence  if incorrect numbers are pressed  a Bad Combo Tone   4 short beeps  will sound and the lock will go to rest  A function that has an on off condition rather  than a numeric setting requires a 1  on  or a 0  off  as the Function Setting     Note  If a default setting is what is desired  then the setting of that function is not necessary     5 1 Time Delay Settings  Functions 01  02  amp  03   5 1 1 To Enable Time Delay   C    01     Master Code     1    5 1 2 To Disable Time Delay   C     01       Master Code     0    5 1 3 To set the Delay Period   C      02       Master Code         Delay Period  1 99 minutes       5 1 4 To set the Open 
5. 14   121314      2  Then  Add User 3 with  3  And finally set a combo for User 3       5 3 Duress Alarm  Function 20   5 3 1 To Enable Duress Mode   C       20        Master Code        1      5 3 2 To Disable Duress Mode   C       20        Master Code        0      5 4 Dual Combo  Functions 30  amp  31   5 4 1 To Enable Dual Combo Mode   C       30        Master Code        1     Note  Enabling Dual Combo Mode turns on  enables  User 1 if a User 1 is not already active in  Multi User mode  The User 1 combo must be set before this feature will function  See  Section 4 for changing instructions   5 4 2 To Disable Dual Combo Mode   C       30       Master Code        0      5 4 3 To Enable 2 Subordinate User Opening in Dual Combo Mode   C    31     Master Code     1    5 4 4 To Disable 2 Subordinate User Opening in Dual Combo Mode     C     31        Master Code     0      5 5 Armored Car TDL Bypass  Functions 40  amp  41   5 5 1 To Enable Armored Car TDL Bypass   C     40       Master Code     1    Note  Enabling Armored Car Bypass turns on  enables  User 9  which is the Armored Car User     The User 9 combo must be set before this feature will function  See Section 4 for  changing instructions     AGNA OGCULILY FIUUULL UV     5 5 2 To Disable Armored Car TDL Bypass   C     40       Master Code        0      5 5 3 To Enable Subordinate Authorizing User Armored Car TDL Bypass   C     41       Master Code       1     5 4 4 To Disable Subordinate Authorizing User Armored Car TDL
6. AGNA OGCULILY FIUUULL UV     Operating Instructions for the ESL20 Electronic Safe Lock    Your AMSEC ESL20 Electronic Safe Lock has a Master Combination of  C 1 2 3 4 5 6      To open the lock  simply press the    C    key to clear and wake up the electronics  Now press the  keys of the combination one at a time and finish with the         key  If the combination keyed is  correct  the lock will cycle open for three  3  seconds  During this 3 second period  turn the handle  of the safe to the unlocked position and pull the door open     Contents    Section Description Page  1 ESL20 Lock Features   A few things to remember about using the ESL20 Safe Lock   Users   Combination Changing   Lock Feature Setting and Function Codes   Mixed Operating Modes   Record Keeping    NOOR WP  ONoaRWD        1   ESL20 Lock Features    The ESL20 Electronic Safe lock has many advanced features used in commercial applications   These features offer the Supervisor  referred to as the Master User  the ability to manage access to  the safe in many ways  The features are     1 1 Time Delay  Time delay forces the user to wait a pre determined time period before the  safe can be opened  This feature is a robbery deterrent  whereby the user can cooperate  with a robber in opening the safe  but forces the robber to wait before access is granted   The idea is that a robber is too impatient to wait that long and gives up  Time delay  periods are typically set for 10 or 15 minutes  The ESL20 can be set for
7. Period   C      03       Master Code         Open Period  1 9 minutes         Time Delay Setting Example  To set Time Delay for 12 minutes  Open Period to 4 minutes and  the Master Combo is 159260  you must execute 3 function codes as follows     1  First  Enable the Time Delay with  2  Then  set the Delay Period with  3  And finally set the Open Period with    C   01   159260   1    C   02   159260   12    C   03   159260   4         5 2 Multiple User Settings  Functions 10  11  12  amp  13    5 2 1 To Enable Multiple User Mode   C   10     Master Code     1     5 2 2 To Disable Multiple User Mode   C   10     Master Code     0     5 2 3  To Add or Enable a Subordinate User   C    11     Master Code        User Number  1 8        5 2 4 To Disable a Subordinate User     C    12     Master Code        User Number  1 8         Document Part No  4305149  Revision C 18 Sept  2000    AGNA OGCULILY FIUUULL UV     5 2 5 To Disable all Subordinate Users  1 8    C   13     Master Code     1    Note  Disabling a Subordinate User does not erase the combo associated to that user  so if you    re enable that User number it is not necessary to re enter a combo for it unless you are  treating it as a new user     Enabling Multi User Mode and Adding a New User Example  To add a User 3 and set a  combination for that User  the Master Combo is 159260 and set User 3 combo to 121314     1  First  Enable Multiple User Mode with C   10   159260   1      C   11   159260   3    C   3   159260   1213
8. eir own combination   b  Two Subordinate Users opening the safe in Dual Combo Mode   c  The Subordinate User authorizing Armored Car Time Delay Bypass     Reset All Functions  A function has been provided to reset all the functions to what is  considered    default    settings  It disables all the various modes  deletes all the users  their  codes  and cleans up any unknown settings  This is useful to get a fresh start after  programming has been lost track of or for personnel changes at the Master User level     A few things to remember     With each keystroke the red lamp on the keypad will flash and a chirp can be heard     If 4  four  incorrect combinations are entered  the lock will go into a    Penalty Lockout    for 15  minutes to prevent trial and error manipulation attempts at opening the lock  The red lamp will  flash once every 5 seconds during the penalty period  If you press any key during the lockout  period  the red lamp will flash with a chirp 8 times rapidly to indicate the lockout condition   Note that removing power during lockout will only re start the penalty timing     Before keying the combination  be sure that the handle of the safe is in the fully locked  position to allow the lock to open freely     AINGMGAall OGCULILY FIUUULL UV     2 4 If the lock fails to open or acts strange  replace the batteries with good quality fresh alkaline 9   volt batteries  To replace the batteries  simply turn the keypad housing counter clockwise to  the stop and pull i
9. me  the Master User combo can be changed by keying   C        Old Master Code         New Master Code         New Master Code         4 2 Multiple User Mode Change and F60 1  Changing of any combination  including the Master  User Code  can be changed by the following sequence     C      User No          Old User Code         New User Code         New User Code         4 3 In the event Function 60 is Disabled  F60 0  or you are adding a new User  then the combo  change must be authorized with the Master User s code     C       User No          Master Code         New User Code         New User Code         Combination Change Examples    The Master Combo is 159260 and you wish to change it to 918273  Do the following   C   0   159260   918273   918273   or C   159260   918273   918273     User 5   s combination is 342312 and you wish to change it to 768798  C   5   34231 2   768798   768798     User 5   s combination is unknown and you wish to set it to 768798  the Master Combo is 159260  C   5   159260   768798   768798         5 Lock Feature Setting and Function Codes     The ESL20   s advanced features are controlled only by the Master User  and are set using Function  Codes  A function can be turned on and off  or set  using the Function Code with the Master User  code as authorization for changing or setting the function  A Function Code is a 2 digit code that  associates to a particular setting  Each Function Code has a default  or standard setting  which is in  the lock
10. sible  The Master User  User 0  is the one and only code that  is allowed to control all the other users  their access privileges and function setting  Users 1 8 are  only active if Multi User mode is Enabled and the individual User Number has been Enabled and a  combination entered for that user by the Master User     3 1 User0  Designated the Master User  Has control over all Subordinate Users and setting of  all functions     3 2 Users 1 through 8  Referred to as Subordinate Users  They only have access and privileges  as the Master User assigns them     3 3 User9  Armored Car Code  This is a special code used only for the purpose of bypassing  the Time Delay  This code will not open the lock alone  only authorize an opening when Time  Delay is active     4 Combination Changing    One of the strengths of an electronic safe lock is the quick and easy changing of the  combination s   This adds to security because you can change it at will if you suspect your  combination is known by others     The combination change method for the Primary code  Master User  can be done two ways  with or  without a User Number  All combination changes require and authorization code and two entries of  the new combo as verification     Note  In the event that Function 60  Subordinate Combo Change  is set to Disable  F60 0   only  the Master Code will authorize a change     Document Part No  4305149  Revision C 18 Sept  2000    AGNA OGCULILY FIUUULL UV     4 1 Master User Code change  At any ti
11. t Part No  4305149  Revision C 18 Sept  2000    AGNA OGUCULILY FIUUULL UV     7 Record Keeping Aids    Use this table to track Function Settings               Date      Date    F   Function Description   range     T T T T    01   TimeDelayMode   toro   TT T    T      02   Time Delay Period S  19   TT T T       03   OpenPeriod   to      T T T      10   Multiple User Mode   toro      T T T     Duress Mode ioro f T T T T      30   Dual Combo Mode   toro       T T T T     Two Subord  Combos Open   toro   J J J T J  Armored Car TDL Bypass aoro f T T T T ee    41   Subord  Auth  of TDL Bypass   toro      1 T T T    External Control Port   toro   f T T T T       60   Subord  User Combo Change   toro     T1 T1 T T      Use this table to track Users    Assigned To Assigned To Assigned To  No                      
12. t away from the base  Un snap the old batteries and clip on the new ones   Position them in the pocket at the bottom of the housing and replace it  watching that the wires  are not pinched  You should replace your batteries once a year to prevent corrosion damage  from leaking batteries     2 5 During any input sequence  if you make a mistake  you can press    C    to clear the previous  input and start over again     2 6 The ESL20 uses a fixed length 6  six  digit combination     2 7 Use only your fingers to key the combination  Sharp objects will result in damage  which is not  covered by the warranty     2 8 If at any time during opening or combination changing the unit is left without input for 10  seconds  it returns to a resting condition  If this occurs during a combination change  the Old  Combination is retained     2 9 At any time during opening or combination changing the unit will register the first 5 digits of the  combination into the    buffer    that receives input  The 6  digit will be the last numeric key  pressed  For example  if your press C 1 2 3 4 5 7 4 5 2 7 6   the program recognizes only  the C 1 2 3 4 5 6   input  The last numeric key pressed continues to replace the one prior  until the         key is pressed to indicate completion  This is a security feature that allows you to  baffle an on looker that may be trying to memorize your combination  This is the electronic  equivalent to a Spy proof Dial     3 Users    There are 10 User Combinations pos
13. tly signal that they are under duress  or being forced to open the safe in a robbery  situation  When a user keys a combination  finishing with the last number of the  combination 1 digit high or 1 digit low  a one second contact closure of the output relay is  caused  This contact closure is the same as if someone had pushed a    panic    button to  summon help  By signaling secretly at the safe  the user doesn   t risk angering the robber  and possible injury     External Control  This feature allows the ESL20 to be disabled and enabled by an auxiliary  device like an Access Manager  Key Switch  external Alarm System  etc  The Expansion  Modules  ESLAC  ESL20EXP1 and ESL20EXP2  provide terminals for external device  connection  When the External Control Mode is enabled and the Lock Enable input loop  is open  the lock will not open when a combo is entered  it will indicate with a quick 4  beep flash  The Factory Reset Code will clear this condition if it was set accidentally     Auxiliary AC Power  The ESL20 can utilize an external power source to operate at  optimum performance with the batteries acting as a backup system in the case of power  failure  This feature requires one of the Expansion Modules  ESLAC  which includes a  transformer  or an ESL20EXP1 or ESL20EXP2 with the ESLTFMR added     Subordinate User Control  The Master User has the option of allowing or not allowing  certain capabilities of the Subordinate Users as follows   a  The Subordinate User changing th
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
USER`S MANUAL - Icon Heath & Fitness  Oracle Audio Technologies B31003-01 User's Manual  Samsung Galaxy Tab 2 (10.1, 3G) Vartotojo vadovas  I -MANUALE DI ISTRUZIONE PER APPARECCHIO DI TAGLIO AL  Numero Completo - Diocesi di Como  Parcan 16 - Controllux  Dicota Lid Cradle  Información del Documento Original    DO MORE WITH YOUR HOME PHONE    Copyright © All rights reserved. 