INSTALLATION MANUAL & OWNER'S GUIDE ULTRAVIOLET
Contents
1. Consult Factory to determine part number for applications other than 120V 60hz not shown RACK SYSTEM ASSEMBLY AND INSTALLATION PROCEDURES PREPARATION INSPECT ALL PARTS NOTE Read Assembly and Installation instructions on this page and UVBB System Installation and Activation Procedures on Page 6 before assembling Rack System NOTE Item numbers in the following table refer to Figures 4 and 5 Parts List Rack System Item Description Qty 1 Feet 18 46cm deep 2 2 Legs 42 107cm high 2 3 Leg Brace 34 1 4 87cm wide 1 4 Corner Braces 4 5 Top 34 1 4 87cm wide 1 6 Lock Nut 1 4 20 22 7 Flat Washer 1 4 44 8 Hex Bolt 1 4 20 x 1 22 9 Flat Washer 5 16 16 10 Lag Bolt 5 16 x 1 1 4 16 11 Mounting Adapter Plate 1t 12 Screw 6 32 x 3 8 4t t Per UV Control Module as specified for applicable configuration NOTE See Page 7 for UVBB detailed parts breakdown Refer to the label affixed to the UVBB mounting bracket to identify housing units to be installed on rack RACK ASSEMBLY NOTE Items in this section refer to Figure 4 CAUTION Maximum load for the Rack System is 750 Ibs 340 kg This system is designed for indoor use only NOTE Each UVBB 1 housing assembly can process up to 15 gpm 57 L min Up to four assemblies may be installed on the Rack System Four housing assemblies may be plumbed in par
2. O rings for damage i e nicks or scratches Replace damaged rings CAUTION Use care when cleaning UV head Do not get the UV control module or connectors wet 7 Clean sumps and heads inside and outside with washcloth and cleaning solution Do not use abrasive materials 8 Rinse sumps and heads with clean potable water 9 For UV20 Model only Clean and rinse the Stainless Steel Channeling Sleeve Item 3 and Sleeve Gasket Item 4 shown in Figure 2 10 Inspect head and sump ring groove area for damage i e nicks or scratches Replace damaged components 11 Place a small amount of silicone based ring lubricant on the filter sump ring Install the ring into the filter sump groove DISINFECTION PROCEDURE CAUTION WEAR SAFETY GLASSES AND SANITARY RUBBER GLOVES WHILE PERFORMING THIS PROCEDURE CAUTION EXCESSIVE CONCENTRATIONS OF BLEACH WILL DAMAGE PLASTIC AND RUBBER COMPONENTS Rinse all parts that contact bleach thoroughly with clean potable water CAUTION Read the WARNINGS on the bleach container before using CAUTION Handle sanitizing solution carefully Avoid contact with unprotected areas 1 Disconnect system from electrical outlet 2 Mix sanitizing solution a ForUVB UV1 and Addon Models only Mix 59 ml 1 4 cup of household bleach and 177 ml 3 4 cup of clean potable water in the bucket Mix the solution well b For UV20 and UVBB Mod
3. ACTIVATE SYSTEM CAUTION Verify that inlet and outlet ports are connected to appropriate inlet outlet pipes see Figure 3 1 Plug system into an electrical outlet If the LED Indicator Item 8 does not light up within one minute verify UV lamp is securely plugged into UV control module It is normal for the LED indicator to flicker slightly NOTE The UV lamp should remain on at all times during use because repeated starting of UV lamp shortens lamp life and UV lamp requires a warm up period of 1 2 minutes 2 Turn on water supply and check for leaks 3 Flush system connectors and water lines for several minutes to remove carbon fines NOTE When an ultraviolet water treatment system is unused for several hours water within system could become warm This is a normal condition To cool the water dispense water from system NOTE System is now ready for use Service Requirements Recommended Service Intervals To ensure the system operates at its optimum level certain routine maintenance must be performed Frequency of maintenance performance will depend on source water quality and level of system usage CLEAN Each time filters are replaced DISINFECT At least once a year UV lamp 20 Change Annually Quartz Sleeve 22 Clean when changing filters Replace only if damaged or cannot be cleaned by non abrasive methods Filters Normal life 4 6 months Filter life will vary due to water condition
4. UV light from the sun has long been known for its ability to destroy microorganisms However it has only been in recent years that equipment producing UV light has been manufactured for residential use WARNING NEVER LOOK DIRECTLY AT A LIGHTED UV LAMP ULTRAVIOLET RAYS CAN BE HARMFUL TO EYES UV energy is produced by low pressure mercury vapor enclosed in a tubular lamp While a UV lamp resembles a standard fluorescent lamp it is similar in appearance only Energy produced by the UV lamp has the ability to destroy microorganisms that can live in water There are five major groups of microorganisms that are altered by a specific spectrum of ultraviolet light viruses bacteria fungi algae and protozoa When these microbes are exposed to the proper amount of UV energy their DNA structure is scrambled and they are unable to reproduce Since the cell is now sterile or dead it is no longer a threat WHAT IS ACTIVATED CARBON Activated carbon has been used for hundreds of years to treat taste odor and color problems in water Activated carbon has been proven to be an excellent media to produce better tasting water and to remove harmful water contaminants at a reasonable cost Carbon used for filters may be manufactured from wood coal or coconut shells The raw carbon is ground up and activated by heating the granules at a controlled temperature and pressure This process causes the carbon granules to expand and create
5. filter head CAUTION DO NOT INSTALL A DAMAGED LAMP 5 Remove UV Control Module Item 10 from Mounting Bracket Item 6 6A or 6B by removing four Screws Item 11 NOTE Hold UV lamp by ceramic ends only Do not touch glass Clean it with isopropyl alcohol if necessary 6 Remove UV Lamp Item 16 from packing tube and inspect it for damage If damage is found contact the dealer for a replacement 7 Connect UV lamp into four pin socket located at the bottom of UV control module 8 Verify Safety Plunger Rod Item 18 is in place NOTE System with Light Out Circuit LOC does not have a safety plunger rod 9 Carefully insert the UV control module with UV lamp through mounting bracket into the quartz sleeve and replace screws removed in Step 5 ACTIVATE SYSTEM CAUTION Verify that inlet and outlet ports are connected to appropriate inlet outlet pipes see Figure 2 1 Plug system into an electrical outlet If the LED Indicator Item 8 does not light up within one minute verify UV lamp is securely plugged into UV control module and safety plunger rod is in place see Note in Step 8 above It is normal for the LED indicator to flicker slightly NOTE The UV lamp should remain on at all times during use because repeated starting of UV lamp shortens lamp life and UV lamp requires a warm up period of 1 2 minutes 2 Turn on water supply and check for leaks 3 Flush system connectors and water lines for sever
6. Being careful not to dislodge quartz sleeve install sump with filter sleeve assembly onto UV head 5 Loosen Screw Item 9 securing slotted side of UV Lamp Retainer Item 7 Remove the other screw securing the UV lamp retainer to UV head Rotate UV lamp retainer away from center of UV head CAUTION DO NOT INSTALL A DAMAGED LAMP NOTE Hold UV lamp by ceramic ends only Do not touch the glass Clean glass with isopropyl alcohol if necessary 6 Remove the UV Lamp Item 17 from packing tube and inspect it for damage If damage is found contact the dealer for a replacement 7 Connect UV lamp into the four pin socket that is connected to the UV Control Item 11 8 Carefully insert the UV lamp through mounting bracket into the quartz sleeve as far as possible NOTE End of UV lamp will touch bottom of quartz sleeve 9 Slide Finish Cap Item 13 on UV control cable and snap finish cap into Spacer Bushing Item 12 10 Rotate UV lamp retainer towards UV lamp such that the retainer will secure the UV lamp Replace the screw removed in Step 5 Tighten screw loosened in Step 5 ACTIVATE SYSTEM CAUTION Verify that inlet and outlet ports are connected to appropriate inlet outlet pipes see Figure 7 WARNING NEVER LOOK DIRECTLY AT A LIGHTED UV LAMP ALWAYS LOOK AT LAMP THROUGH FINISH CAP ONLY 1 Plug system into an electrical outlet The finish cap should illuminate within one minute indicating UV lamp is on If it d
7. UV COMPONENTS Refer to system Parts List for specific component part numbers Refer to system Parts List for specific component part numbers CLEANING PROCEDURE NOTE Refer to individual System Assembly and Activation Procedures to identify specific components matching the descriptions shown in this procedure 1 Disconnect system from electrical outlet 2 Mixamild cleaning solution of dish soap and clean potable water in the plastic bucket 3 Close feed water supply valve and open downstream faucet to relieve system pressure CAUTION Do not attempt to remove sumps until water flow stops This reduces pressure inside the system so sumps may be safely removed NOTE For UVB and UV1 Models only Remove and save Teflon Sleeve as it will be used again with replacement EPCB Carbon Filter 4 Remove each sump Remove each filter as its sump is removed Discard the filters Use sump wrench to remove stubborn sumps NOTE Use sanitary rubber gloves for this procedure to avoid contaminating cleaning solution or filters Wear gloves whenever cleaning components or handling new filters 5 Clean quartz sleeve carefully using vinegar to remove hardness Do not use abrasive materials Rinse sleeve thoroughly with clean potable water Replace any sleeve that is damaged or will not come completely clean 6 Remove sump O rings and wash with cleaning solution Rinse them well with clean potable water Inspect
8. bag with other hand to expose open end 3 Place a small amount of silicone based ring lubricant on the outside of the open end of the quartz sleeve only on the area that will engage with the O ring CAUTION Apply even pressure to push the quartz sleeve into the UV head To avoid breakage make sure quartz sleeve goes in straight by pushing it with a slight twisting motion 4 Insert quartz sleeve into the UV head As quartz sleeve passes both Rings Item 15 resistance will be felt Remove protective bag from quartz sleeve 5 Remove EPCB Carbon Filter Irem 3 and EPCB Sleeve Item 24 from sump and set aside 6 ForUVB2 and UVB3 Models only Remove Sump Item 1 from Filter Head Item 20 Remove Filters Items 21 and 23 from sump and set aside 7 Disinfect the system Pages 15 16 Steps 1 7 INSTALL ULTRAVIOLET LIGHT AND FILTERS 1 Remove Sump Item 1 from UV Head Item 5 NOTE Wipe all fingerprints and excessive lubricant from quartz sleeve with isopropyl alcohol 2 Install EPCB Sleeve Item 24 into EPCB Carbon Filter Item 3 as shown in Figure 1 3 Insert filter sleeve assembly into sump as shown in Figure 1 with both Filter Gaskets Item 4 in place CAUTION TIGHTEN SUMPS BY HAND ONLY Do not use tools as they will over tighten and may damage sump Take care not to cut or pinch Rings Item 2 Use sump wrench for removal only 4 Being careful not to dislodge quartz
9. cm x 5 5 14 0 cm 24 0 Ibs 10 9 kg 25 0 63 5 cm x 11 0 27 9 cm x 5 5 14 0 cm Flow Rate Gallons Per Minute Liters per Minute 2 gpm 7 6 L min 10 gpm 38 L min 32 0 Ibs 14 5 kg 25 0 63 5 cm x 16 0 40 6 cm x 5 5 14 0 cm 20 0 Ibs 9 1 kg 29 5 74 9 cm x 7 5 19 0 cm x 9 0 22 9 cm 35 0 16 15 9 kg 28 0 71 1 cm x 15 0 38 1 cm X 9 0 22 9 cm 53 Ibs 24 0 kg 28 0 71 1 cm x 23 0 58 4 cm X 9 0 22 9 cm 7 0 Ibs 3 2 kg 13 5 34 3 cm x 5 0 12 7 cm x 5 0 12 7 cm 5 0 Ibs 2 3 kg 12 0 30 5 cm x 4 0 10 2 cm x 3 5 8 9 cm 8 gpm 30 L min 15 gpm 57 L min 1 gpm 3 8 L min 1 gpm 3 8 L min Lamp Type amp Power Used Watts UV Lamp 11 14 Watts UV Lamp 20 22 Watts UV Lamp 20 22 Watts UV Lamp 10 10 Watts UV Lamp 10 10 Watts 7 0 Ibs 3 2 kg 22 5 57 2 cm x 4 0 10 2 cm x 3 5 8 9 cm t Female thread as recognized by United Sates National Pipe Thread Push in Quick Connectors or Quick Connectors QC All dimensions of system do not include inlet outlet piping connections and are rounded up to the nearest 1 2 3 gpm 11 4 L min UV Lamp 20 22 Watts Inlet Outlet WARNING NEVER LOOK DIRECTLY AT A LIGHTED UV LAMP ULTRAVIOLET RAYS CAN BE HARMFUL TO EYES ALWAYS SHUT OFF WATER TO SYSTEM AND DISCONNECT POWER WHEN SERVICING ASSEMBLY IS REQUIRED BEFORE INSTALLAT
10. last approximately four to six months Filter life will vary due to water conditions A reduced flow rate or deteriorating water quality indicates that filters must be changed Use only PURA filters PURA filters are specially designed to work in the ultraviolet disinfection process NOTE Presence of iron or general poor water quality will require frequent inspection and cleaning Use of non PURA filters voids the warranty CAUTION Use care when changing the filters to avoid Rings Lubricate each O ring with a silicone based ring lubricant to ensure a proper seal breaking the quartz sleeve UV Lamp Replacement Lamps must be changed every NOTE UV lamp should remain on at all times during use because repeated starting of UV lamp shortens lamp life and UV lamp requires a warm up period of 1 2 minutes twelve months While UV lamps rarely burn out they do lose their disinfection power Use only PURA UV lamps as they are specifically designed for the PURA system to deliver high quality drinking water PURA ULTRAVIOLET SPECIFICATIONS Dimensions Inches Centimeters Height x Width x Depth Shipping Weight Ibs Kg 10 0 Ibs 4 5 kg 15 0 38 1 cm x 5 5 14 0 cm x 5 5 14 0 cm 15 0 Ibs 6 8 kg 15 0 38 1 cm x 11 0 27 9 cm x 5 5 14 0 cm 24 0 Ibs 10 9 kg 15 0 38 1 cm x 16 0 40 6 cm x 5 5 14 0 cm 16 0 Ibs 7 3kg 25 0 63 5 cm x 5 5 14 0
11. protective bag from quartz sleeve NOTE Wipe all fingerprints and excessive lubricant from quartz sleeve with isopropyl alcohol 6 For UVBB 2 and UVBB 3 Models only Remove Sump Item 1 from Filter Head Item 20 Remove Filters Items 21 and 22 from sump and set aside 7 Disinfect the system Pages 15 16 Steps 1 7 INSTALL ULTRAVIOLET LIGHT AND FILTERS CAUTION TIGHTEN SUMPS BY HAND ONLY Do not use tools as they will over tighten and may damage sump Take care not to cut or pinch Rings Item 2 Use sump wrench for removal only 1 For UVBB 2 and UVBB 3 Models only Remove Sump Item 1 from Filter Head Item 20 Install Filters Items 21 and 22 as shown in Figure 3 Install sump onto filter head CAUTION DO NOT INSTALL A DAMAGED LAMP 2 Remove UV Control Module Item 10 from Mounting Bracket Item 6 6A or 6B by removing four Screws Item 11 NOTE Hold UV lamp by ceramic ends only Do not touch the glass Clean glass with isopropyl alcohol if necessary 3 Remove UV Lamp Item 16 from packing tube and inspect it for damage If damage is found contact the dealer for a replacement 4 Connect UV lamp into four pin socket that is connected to the UV control module by a cable that allows for correct insertion depth 5 Carefully insert the UV control module with UV lamp through mounting bracket into the quartz sleeve making sure the cable does not twist or curl Replace screws removed in Step 2
12. sleeve install sump with filter sleeve assembly onto UV head 5 ForUVB2 amp UVB3 Models only Remove Sump Item 1 from Filter Head Item 20 Install Filters Items 21 and 23 as shown in Figure 1 Install sump onto filter head CAUTION DO NOT INSTALL A DAMAGED LAMP 6 Remove UV Control Module Item 10 from Mounting Bracket Item 6 6A or 6B by removing four Screws Item 11 NOTE Hold UV lamp by ceramic ends only Do not touch the glass Clean with isopropyl alcohol if necessary 1 Remove UV Lamp Item 16 from packing tube and inspect it for damage If damage is found contact the dealer for a replacement 2 Connect UV lamp into four pin socket located at the bottom of UV Control Module Item 10 3 Verify Safety Plunger Rod Item 18 is in place NOTE System with Light Out Circuit LOC does not have a safety plunger rod 4 Carefully insert the UV control module with UV lamp through mounting bracket into the quartz sleeve and replace screws removed in Step 6 ACTIVATE SYSTEM CAUTION Verify that inlet and outlet ports are connected to appropriate inlet outlet pipes see Figure 1 1 Plug system into an electrical outlet If the LED Indicator Item 8 does not light up within one minute verify UV lamp is securely plugged into UV control module and safety plunger rod is in place see Note in Step 9 above It is normal for the LED indicator to flicker slightly NOTE The UV lamp should remain on at all
13. times during use because repeated starting of UV lamp shortens lamp life and UV lamp requires a warm up period of 1 2 minutes 2 Turn on water supply and check for leaks 3 Flush system connectors and water lines for several minutes to remove carbon fines NOTE When an ultraviolet water treatment system is unused for several hours water within system could become warm This is a normal condition To cool the water dispense water from system NOTE System is now ready for use Service Requirements Recommended Service Intervals To ensure the system operates at its optimum level certain routine maintenance must be performed Frequency of maintenance performance will depend on source water quality and level of system usage CLEAN Each time filters are replaced DISINFECT At least once a year UV Lamp 11 Change Annually Quartz Sleeve 11 Clean when changing filters Replace only if damaged or cannot be cleaned by non abrasive methods Filters Normal life 4 6 months Filter life will vary due to water conditions A reduced flow rate or deteriorating water quality indicates that filters must be changed SEDIMENT FILTER COMPONENTS UVB2 EPCB SD S 9505 0900 005 06 0004 0006694 90 055 00605 000 X zs 00 l es 90 R BERSSEBS XX e 90 600 e 05 S x lt gt
14. 000005 XXX 5255 eC 0060909 0650 re SRS lt x XXX S RS RS KOO SS ROKK 905055 09505 5 k gt S 99 5 aces es 9600050500005 ZZXX f UV COMPONENTS UVB1 EPCB CARBON FILTER COMPONENTS UVB3 EPCB GC SD Figure 1 Exploded Schematic PURA UVB Series Parts List UVB Series Item Description Part No Item Description Part No Item Description Part No 1 Sump 10 153001 06 7 Switch Safety 17 Sleeve Quartz 11 36003034 2 O Ring Sump 10 20 151120 8 Idicaton LED with Rings 3 Filter Carbon EPCB 33004030 9 Fuse 1A 31000006 18 Rod Safety Plunger 22401015 10 10 Module UV Control 11 40200116 19 Spacer Bushing 10 20 22401016 4 Gasket c w Filter 11 Screw 6 32 x 3 8 32701063 20 Head Filter 3 4 10 20 154017 5 Head UV 10 20 36005701 12 Screw 10 x 3 4 32701006 21 Filter Sediment 10 5 micron 33003051 6 Mounting Bracket 31910101 13 Screw 14 x 1 32701060 22 Nipple 3 4 33601023 1 Sump 14 Washer 14 Nylon 32800031 23 Filter GC 10 5 micron 33004024 Mounting Bracket 31910201 15 O Ring Quartz Sleeve 34202021 24 Sleeve Teflon 30120506 2 Sump Standard 2 25 Bushing 3 4 x 3 8 33300017 6B pow Br
15. 0600000600090 KK 0006000600060 Mete ete ete e e Mete ete e e e e S RRR KKK 0500000000 0606000060900 0000000909004 Mete ete e e e e 0600000000904 SLRS l E Figure 7 Exploded Schematic PURA UV1Series Parts List UV1 Series Item Description Part No Item Description Part No Item Description Part No 1 Housing UV1 Pura 92500 1 7 Retainer UV Lamp UV1 31910408 13 Cap Finish c w Control 2 O Ring UV1 Pura 92060 8 Washer 14 Nylon 32800031 14 Sleeve Quartz 10 36003033 3 Filter Carbon EPCB 10 33004030 9 Screw 10 16 x 1 32701007 with O Rings 4 Gasket c w Filter 10 Screw 10 x 3 4 32701006 15 Sleeve Teflon 30120506 5 Spacer UV1 Pura 32701010 11 UV Control 40200080 16 Ring Quartz Sleeve UV1 2 34202020 6 Mounting Bracket UV1 31910107 with Finish Cap 17 Lamp UV 10 36002016 Pura 12 Bushing Spacer 10 SL 22401017 t Consult Factory to determine part number for applications other than 120V 60hz 92500 1 includes Items 1 2 5 8 9 amp 16 11 ADDON SERIES SYSTEM ASSEMBLY AND ACTIVATION PROCEDURES PREPARATION INSPECT ALL PARTS NOTE Read Mounting Bracket and System Plumbing Installation instructions on Page 1 and all instructions on this page before installing system ADDON SERIES Addon Ultraviolet System Ultraviolet Lamp in pa
16. INSTALLATION MANUAL amp OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS UVB SERIES UV20 SERIES lo 8 o 0A n n m WR R RACK SYSTEM UVBB SERIES UV1 SERIES ADDON SERIES 00 36103017 Rev 2 08 INTRODUCTION INSTALLATION Hi 00 00 MAINTENANCE TABLE OF CONTENTS DESCRIPTIONS AND DEFINITIONS CONDITIONS FOR USE ROUTINE MAINTENANCE SPECIFICATIONS MOUNTING BRACKET AND PLUMBING UVB SERIES INSTALL QUARTZ SLEEVE AND DISINFECT SYSTEM INSTALL ULTRAVIOLET LIGHT AND FILTERS ACTIVATE SYSTEM SERVICE REQUIREMENTS AND RECOMMENDED INTERVALS PARTS ILLUSTRATION PARTS LIS
17. ION FRAGILE PARTS INSIDE FOLLOW INSTRUCTIONS CAREFULL Y The system must be installed in accordance with applicable city country and local plumbing codes PURA products are designed to provide years of trouble free service if properly maintained Retain these instructions for future reference MOUNTING BRACKET AND SYSTEM PLUMBING INSTALLATION This Guide covers installation and maintenance of a basic generic system Installer determines configuration of each system and must adapt these instructions to meet the specific requirements for that configuration Specific component and assembly information is provided only for components that are unique to PURA systems All inter component connections use standard plumbing components and tools INSTALL MOUNTING BRACKET CAUTION Do not use any damaged component If damage is found contact your dealer before proceeding 1 Unpack boxes and verify that all required components have been received see Preparation section for your particular series 2 Inspect each component for damage 3 Determine location for installation of the UV system a The PURA UV System should be installed with the sumps oriented vertically CAUTION The UV system may be installed horizontally but the quartz sleeve will be in a position that makes it susceptible to breakage b Mounting point should allow sufficient room above and below UV system to service the sumps and UV lamp without removing the U
18. N TIGHTEN COLLAR BY HAND ONLY Do not use tools as they will over tighten and may damage sump Take care not to cut or pinch Addon Sump Gasket Item 2 1 For ADDON 1GPM Model Only Remove Collar Item 15 from UV Head Item 5 NOTE Wipe all fingerprints and excessive lubricant from quartz sleeve with isopropyl alcohol 2 Disinfect the system Pages 15 16 Steps 1 7 INSTALL ULTRAVIOLET LIGHT CAUTION DO NOT INSTALL A DAMAGED LAMP NOTE Hold UV lamp by ceramic ends only Do not touch the glass Clean glass with isopropyl alcohol if necessary 1 Remove the UV Lamp Item 16 or 16A from packing tube and inspect it for damage If damage is found contact the dealer for a replacement 2 Connect UV lamp into the four pin socket that is connected to the UV Control Item 10 3 Carefully insert the UV lamp through Ring Retainer Item 11 into the quartz sleeve as far as possible NOTE End of UV lamp will touch the bottom of quartz sleeve 4 Slide Finish Cap Item 12 on UV control cable and snap finish cap into O Ring Retainer Item 11 INSTALL TUBING PLASTIC TUBING 1 Cuttube ends square and straight Do not deform tube i e cause tube to compress its diameter so it is no longer round 2 Make sure outer surface of tube is clear of marks or scratches for a length equal to twice tube diameter This allows O rings to seat properly against tube 3 Avoid sharp changes in direction when routing
19. T UV20 SERIES INSTALL QUARTZ SLEEVE AND DISINFECT SYSTEM INSTALL ULTRAVIOLET LIGHT AND FILTERS ACTIVATE SYSTEM SERVICE REQUIREMENTS AND RECOMMENDED INTERVALS PARTS ILLUSTRATION PARTS LIST UVBB SERIES INSTALL QUARTZ SLEEVE AND DISINFECT SYSTEM INSTALL ULTRAVIOLET LIGHT AND FILTERS ACTIVATE SYSTEM SERVICE REQUIREMENTS AND RECOMMENDED INTERVALS PARTS ILLUSTRATION PARTS LIST RACK SYSTEM UV1 SERIES DISINFECT SYSTEM INSTALL ULTRAVIOLET LIGHT AND FILTERS ACTIVATE SYSTEM SERVICE REQUIREMENTS AND RECOMMENDED INTERVALS PARTS ILLUSTRATION PARTS LIST ADDON SERIES DISINFECT SYSTEM INSTALL ULTRAVIOLET LIGHT INSTALL TUBING ACTIVATE SYSTEM SERVICE REQUIREMENTS AND RECOMMENDED INTERVALS PARTS ILLUSTRATION PARTS LIST CLEANING AND DISINFECTION FILTER REPLACEMENT UV LAMP REPLACEMENT aoa 5 A CQ MN MN NM N 000 Oo 10 10 10 10 11 11 12 12 12 13 13 13 14 14 15 16 16 16 INTRODUCTION DESCRIPTIONS AND DEFINITIONS You have purchased one of the most technologically advanced Ultraviolet Water Treatment System available anywhere in the world It has been designed with you the consumer in mind PURA products are lightweight easy to use and simple to maintain PURA products will provide you with healthy clean drinking water for years to come WHAT IS ULTRAVIOLET Ultraviolet
20. V system The minimum space is UVB 11 above and below UV20 UVBB 20 above and below UV1 10 above and below ADDON 10 or 20 above by model 4 Forease of mounting reduce the weight of the larger systems by removing the sumps and filters prior to installing the mounting bracket 5 Select a location and install the mounting bracket using the provided screws INSTALL SYSTEM PLUMBING CAUTION Water pressure must not exceed 75 psig 517 kPa or a pressure regulator must be used CAUTION Do not install pump on outlet side of system as damage to the quartz sleeve may occur If pump is required install it on inlet side of system and verify output pressure does not exceed 75 psig 517 kPa CAUTION Warranty is void if the unit is used with pressure exceeding 75 psig 517 kPa Higher pressures may damage equipment and may not allow for proper exposure time with UV lamp or both CAUTION The system will not function properly if water flow is reversed See the Exploded Schematic for your model on the following pages to ensure proper flow direction 1 Turn off source water supply CAUTION PURA recommends using only plastic fittings to connect the inlet and outlet ports of the PURA system Use of metal male fittings inside of plastic female threaded heads voids the warranty CAUTION Do not over tighten fittings connected to inlet outlet ports of the PURA system 2 Connect inlet of UV system to source wate
21. acket 31910301 16 Lamp UV 11 36002017 n st Wrench Sump 10 20 150295 t Consult Factory to determine part number for applications other than 120V 60hz not shown UV20 SERIES SYSTEM ASSEMBLY AND ACTIVATION PROCEDURES PREPARATION INSPECT ALL PARTS NOTE Read Mounting Bracket and System Plumbing Installation instructions on Page 1 and all instructions on this page before installing system UV20 SERIES UV20 Ultraviolet System Ultraviolet Lamp 20 in packing tube Quartz Sleeve 20 in packing tube Mounting Screws 2 4 pieces varies with model Installation Manual and Owners Guide Sump Wrench 710 20 NOTE See Page 5 for UV20 detailed parts breakdown Refer to the label affixed to the mounting bracket to identify filter s to be installed with UV module INSTALL QUARTZ SLEEVE AND DISINFECT SYSTEM CAUTION QUARTZ SLEEVE IS VERY FRAGILE For safety wear a protective glove when handling quartz sleeve Do not touch quartz sleeve or UV lamp with bare hands Fingerprints will reduce the effectiveness of the light NOTE All Items refer to Figure 2 1 Remove Sump Item 1 from UV Head Item 5 NOTE Do not remove protective plastic bag from quartz sleeve until so instructed 2 Remove Quartz Sleeve Item 17 from packing tube While holding middle of quartz sleeve with one hand slide protective bag with other hand to expose open end 3 Place a small amount of silicone
22. active sites where pollutants can be collected by adsorption These new sites dramatically increase the total surface area and capacity of each granule WHAT IS ADSORPTION Adsorption is the physical process where certain water pollutants are attached to the surface of carbon particles as the water flows through the filter The pollutants are removed from the water and locked into the carbon granule Activated carbon is also able to filter out sediment through a process of mechanical filtration The particles are captured in the spaces between carbon granules PURA SYSTEMS PURA recommends that all UV systems include pre filters to process the water before it reaches the UV lamp This will ensure that maximum UV exposure is achieved PURA UVB UV20 and UVBB series offers integrated filters in a single system These integrated systems use a two stage filtration process First a string wound filter removes the suspended solids that may shield the microbes and make it difficult to obtain sufficient UV exposure Second an activated carbon filter removes unpleasant tastes and odors PURA Ultraviolet Water Treatment Systems are designed for indoor use only PURA Systems are designed to provide complete water treatment in a compact easy to use package Please follow the directions in this Guide exactly when installing your PURA System to ensure that it operates correctly The UV lamp requires a start up period of one to two minutes
23. al minutes to remove carbon fines NOTE When an ultraviolet water treatment system is unused for several hours water within system could become warm This is a normal condition To cool the water dispense water from system NOTE System is now ready for use Service Requirements Recommended Service Intervals To ensure the system operates at its optimum level certain routine maintenance must be performed Frequency of maintenance performance will depend on source water quality and level of system usage CLEAN Each time filters are replaced DISINFECT At least once a year UV Lamp 20 Change Annually Quartz Sleeve 20 and Channeling Sleeve Clean when changing filters Replace only if damaged or cannot be cleaned by non abrasive methods Filters Normal life 4 6 months Filter life will vary due to water conditions A reduced flow rate or deteriorating water quality indicates that filters must be changed UV COMPONENTS UV20 1 SEDIMENT FILTER COMPONENTS UV20 2 SD CARBON FILTER COMPONENTS UV20 3 CB20X SD Figure2 Exploded Schematic PURA UV20 Series Parts List UV20 Series Item Description Part No Item Description Part No Item Description Part No 1 Sump 20 153013 7 Switch Safety e 16 Lamp UV 20 36002018 2 O Ri
24. allel See Figure 6 to obtain a maximum flow of 60 gpm 227 L min NOTE Each attachment point requires a Bolt Item 8 two Flat Washers Item 7 and a Nut Item 6 1 Attach the Feet Item 1 to the bottom of each Leg Item 2 NOTE Snug but do not tighten the bolts and nuts connecting the legs and top to the Corner Braces Item 4 until assembly has been squared Attach two corner braces to the upper end of each leg Attach the Leg Brace Item 3 to the back of each leg Attach the Top Item 5 to the corner braces a a V N Square top to the legs Tighten all 16 nuts securing corner braces INSTALL UV SYSTEM TO RACK NOTE Items in this section refer to Figure 5 NOTE Figures 5 and 6 provide examples of configurations that may be applied to your PURA system These configurations are not intended as a representation of a specific system to be installed 1 Determine location for installation of the Rack System with housing assemblies Three requirements for consideration are access to cold water line access to power and proper inlet outlet connection for each housing assembly NOTE Each UV control module has its own cord A power strip may be required if multiple UV control modules are installed on Rack System 2 Install the Rack System Unit may be attached to surface or left freestanding 3 Secure each Mounting Adapter Plate Item 11 and UV head to Rack System with Lag Bolts Item 10 and Flat Washer
25. ated starting of UV lamp shortens lamp life and UV lamp requires a warm up period of 1 2 minutes 2 Turn on water supply and check for leaks If there are leakages in the quick connect fittings check for the ring placement and make sure that the tube is inserted properly refer to Figure 8 3 Flush system connectors and water lines for several minutes to remove carbon fines NOTE When an ultraviolet water treatment system is unused for several hours water within system could become warm This is a normal condition To cool the water dispense water from system NOTE System is now ready for use Service Requirements Recommended Service Intervals To ensure the system operates at its optimum level certain routine will depend on source water quality and level of system usage CLEAN Every 3 to 6 months DISINFECT At least once a year maintenance must be performed Frequency of maintenance performance UV lamp 10 or 20 Change Annually Quartz Sleeve 11 or 20 Clean when changing lamp Replace only if damaged or cannot be cleaned by non abrasive methods 13 UV ADDON 1GPM 14A _1 UV ADDON 3GPM 16A Figure 9 Exploded Schematic PURA ADDON System Parts List UV ADDON Item Description Part No Item Description Part No Item Description Part No 1 Sump 1gpm Addon 31910007 6 Mounting Bracket A
26. based ring lubricant on the outside of the open end of the quartz sleeve only on the area that will engage with the ring CAUTION Apply even pressure to push the quartz sleeve into the UV head To avoid breakage make sure quartz sleeve goes in straight by pushing it with slight twisting motion 4 Insert quartz sleeve into the UV head As quartz sleeve passes both Rings Item 15 resistance will be felt Remove protective bag from quartz sleeve 5 For UV20 2 and UV20 3 Models only Remove Sump Item 1 from Filter Head Item 20 Remove Filters Items 21 and 23 from sump and set aside 6 Disinfect the system Pages 15 16 Steps 1 7 INSTALL ULTRAVIOLET LIGHT AND FILTERS 1 Remove Sump Item 1 from UV Head Item 5 NOTE Wipe all fingerprints and excessive lubricant from quartz sleeve with isopropyl alcohol 2 Verify Stainless Steel Channeling Sleeve Item 3 and Sleeve Gasket Item 4 are in sump as shown in Figure 2 CAUTION TIGHTEN SUMPS BY HAND ONLY Do not use tools as they will over tighten and may damage sump Take care not to cut or pinch Rings Item 2 Use sump wrench for removal only 3 Being careful not to dislodge quartz sleeve install sump with stainless steel channeling sleeve and sleeve gasket onto UV head 4 For UV20 2 amp UV20 3 Models only Remove Sump Item 1 from Filter Head Item 20 Install Filters Items 21 and 23 as shown in Figure 2 Install sump onto
27. cking tube 10 or 20 varies with model Quartz Sleeve in packing tube only for 20 3GPM Model Mounting Screws 2 pieces Installation Manual and Owners Guide NOTE See Page 14 for Addon detailed parts breakdown INSTALL QUARTZ SLEEVE ONLY FOR 3GPM MODEL NOTE Quartz sleeve Item 13 is factory installed for the 1GPM model only NOTE All Items refer to Figure 8 CAUTION QUARTZ SLEEVE IS VERY FRAGILE For safety wear a protective glove when handling quartz sleeve Do not touch quartz sleeve or UV lamp with bare hands Fingerprints will reduce effectiveness of the light 1 Remove Collar Item 15 from UV Head Item 5A NOTE Do not remove protective plastic bag from quartz sleeve until so instructed 2 Remove Quartz Sleeve Item 13A from packing tube While holding middle of quartz sleeve with one hand slide protective bag with other hand to expose open end 3 Place a small amount of silicone based ring lubricant on the outside of the open end of the quartz sleeve only on the area that will engage with the ring CAUTION Apply even pressure to push the quartz sleeve into the UV head To avoid breakage make sure quartz sleeve goes in straight by pushing it with slight twisting motion 4 Insert quartz sleeve into the UV head As quartz sleeve passes both Rings Item 9 resistance will be felt Remove protective bag from quartz sleeve 12 DISINFECT SYSTEM CAUTIO
28. ctions on this page before installing system UV1 SERIES UV1 Ultraviolet System Ultraviolet Lamp 10 in packing tube Mounting Screws 2 pieces Installation Manual and Owners Guide NOTE See Page 11 for UV1 detailed parts breakdown Refer to label affixed to mounting bracket to identify filter to be installed DISINFECT SYSTEM CAUTION QUARTZ SLEEVE IS VERY FRAGILE For safety wear a protective glove when handling quartz sleeve Do not touch quartz sleeve or UV lamp with bare hands Fingerprints will reduce the effectiveness of the light NOTE Sump wrench not included NOTE Quartz sleeve Item 14 is factory installed NOTE All Item callouts refer to Figure 7 1 Remove Sump Item 1 from UV Head Item 5 2 Remove EPCB Carbon Filter Item 3 and EPCB Sleeve Item 15 from sump and set aside 3 Disinfect the system Pages 15 16 Steps 1 7 INSTALL ULTRAVIOLET LIGHT AND FILTERS 1 Remove Sump Item 1 from UV Head Item 5 NOTE Wipe all fingerprints and excessive lubricant from quartz sleeve with isopropyl alcohol 2 Install EPCB Sleeve Item 15 into EPCB Carbon Filter Item 3 as shown in Figure 7 3 Insert filter sleeve assembly into sump as shown in Figure 7 with both Filter Gaskets Item 4 in place CAUTION TIGHTEN SUMPS BY HAND ONLY Do not use tools as they will over tighten and may damage sump Take care not to cut or pinch Rings Item 2 4
29. ddon 31910401 13 Sleeve Quartz 11 36003034 1A Sump 3gpm Addon 31910006 7 Screw 10 x 3 4 32701006 with O Rings 2 Gasket Sump Addon 21001004 8 Screw 10 x 5 8 00318526 13A Sleeve Quartz 20 36003035 3 Plug Bottom 22401031 9 O Ring Quartz Sleeve 34202021 with O Rings 4 O Ring Bottom Plug 34202037 Standard 2 14 Tube Delivery 1gpm 35817019 5 Head UV Addon 44301002 10 UV Control 40200080 14A Tube Delivery 3gpm 22403202 White 1gpm 15 Collar Addon White 22401011 5A Head UV Addon 44301005 11 Refainer O Ring 22401012 16 Lamp UV 10 36002016 White 3gpm 12 Cap Finish c w Control 16 Lamp UV 20 36002018 Part also available in black Consult Factory to determine part number for applications other than 120V 60hz 14 CLEANING DISINFECTING AND ROUTINE MAINTENANCE PROCEDURE RECOMMENDATIONS HAVE ALL COMPONENTS ON HAND AND READY BEFORE BEGINNING PROCEDURE A CLEAN WORK AREA AND EQUIPMENT ARE ESSENTIAL TO PROPERLY CLEAN AND OR DISINFECT THE SYSTEM i e CLEAN HANDS TOOLS WORK SURFACE AND CONTAINERS EQUIPMENT NEEDED Safety Glasses Rubber Gloves Sanitary Wash Cloth Clean and Lint Free Liquid Dish Soap Household Bleach Unscented Only 5 7 Sodium Hypochlorite Plastic Bucket Ring Lubricant Silicone Based REPLACEMENT FILTERS REPLACEMENT
30. els only Mix 237 ml 1 cup of household bleach and 237 ml 1 cup of clean potable water in the bucket Mix the solution well CAUTION Use care when sanitizing UV head Do not get the UV control module or connectors wet CAUTION TIGHTEN SUMPS BY HAND ONLY Do not use tools as they will over tighten and may damage sump Take care not to cut or pinch rings or gaskets Use sump wrench for removal only 3 Addsanitizing solution into system a ForUVB UV1 and Addon Models only Add 237 ml 1 cup of sanitizing solution to the sump that contains the UV lamp b ForUV20 and UVBB Models only Add 473 ml 2 cups of sanitizing solution to the sump that contains the UV lamp 4 Slowly open the feed water supply valve 5 Open all downstream faucets Keep faucets open until a chlorine smell is detected at each faucet then close faucets NOTE Water lines downstream from UV housing must be disinfected to destroy any bacteria that might remain in the pipes 6 Verify disinfection solution has reached every water outlet downstream of UV system Solution must remain in the system for at least four hours 7 Open outlet valve and let water flow for 5 minutes to flush disinfection solution from the water lines ROUTINE MAINTENANCE FILTER REPLACEMENT PROCEDURE 1 Perform Cleaning Procedure Page 15 step1 11 NOTE Do not remove protective plastic bag from filters Open bottom of bag only enough to expose bo
31. in order to achieve full intensity Repeated starting of the UV lamp will shorten its life Therefore it is recommended that the UV lamp remain on at all times during use Source Water Supply Profile Feed Water Pressure CONDITIONS FOR USE Chemical Parameters Max mg L 38 105 gt 3 3 40 5 Iron a lt 5 lt 120 7 gpg lt 0 3 Feed Water Temperature pH Range Total Dissolved Solids Total Suspended Solids Turbidity T Water Pressure must not exceed 75 psig 517 kPa or a pressure regulator must be installed ROUTINE MAINTENANCE It is important that any water treatment system be properly maintained to ensure consistent water quality The information provided on this page is of a general nature See Cleaning Disinfecting and Routine Maintenance Procedure on Page 14 for detailed information Refer to Mounting Bracket and System Plumbing Installation Instructions on Page 1 and the appropriate System Assembly and Activation Procedures for detailed information to install your specific PURA system Cleaning The inside of the system and the quartz sleeve should be cleaned each time the filters are changed Clean all parts except the filters and electronic parts with soap and rinse them thoroughly with clean potable water Dry the inside of the quartz sleeve thoroughly before re assembling system Filter Replacement Filters will normally
32. kdown Refer to label affixed to the mounting bracket to identify filter s to be installed with UV module INSTALL QUARTZ SLEEVE AND DISINFECT SYSTEM CAUTION QUARTZ SLEEVE IS VERY FRAGILE For safety wear a protective glove when handling quartz sleeve Do not touch quartz sleeve or UV lamp with bare hands Fingerprints will reduce the effectiveness of the light NOTE All Items refer to Figure 3 1 Remove UV Sump Item 1 from UV Head Item 5 NOTE of Red Tape Item 23 is affixed to quartz sleeve approximately 3 from the top Do not remove this tape until so instructed Do not remove protective plastic bag from quartz sleeve until so instructed 2 Remove Quartz Sleeve Item 17 from packing tube While holding middle of quartz sleeve with one hand slide protective bag with other hand to expose open end 3 Place a small amount of silicone based ring lubricant on the outside of the open end of the quartz sleeve only on the area that will engage with the ring CAUTION Apply even pressure to push the quartz sleeve into Quartz Adapter Sleeve Item 4 To avoid breakage make sure quartz sleeve goes in straight by pushing it with a slight twisting motion 4 Insert quartz sleeve into quartz adapter sleeve until the top of red tape meets the bottom of the quartz adapter sleeve NOTE Quartz Adapter Sleeve Item 4 is factory installed into the UV Head Item 5 5 Remove Red Tape Item 23 and
33. le or connectors wet 3 Remove sump from UV head and set aside CAUTION Do nottouch quartz sleeve or UV lamp with bare hands Fingerprints will reduce the effectiveness of the light WARNING Do Not Attempt to Remove Quartz Sleeve Damage to system and personal injury may occur if the sleeve is removed incorrectly Contact your dealer if quartz sleeve is broken or needs replacement 4 Clean quartz sleeve carefully using vinegar to remove hardness Do not use abrasive materials Rinse sleeve thoroughly with clean potable water Replace any sleeve that is damaged or that will not come completely clean 5 Gain access to UV lamp a For UVB UV20 UVBB Models only Remove UV Control Module Item 10 from Mounting Bracket Item 6 6A 6b by removing four Screws Item 11 b ForUV1 Model only Loosen Screw Item 9 securing slotted side of UV Lamp Retainer Item 7 Remove other screw securing UV lamp retainer to UV head Rotate bracket away from UV lamp Remove and slide Finish Cap Item 12 on cable towards UV control 6 Remove UV lamp from system being careful not to break UV lamp or dislodge quartz sleeve a ForUVB and UV20 Models only Remove UV control module with UV lamp by gently lifting control module straight up from mounting bracket Grasp UV lamp firmly and remove lamp from the four pin socket b ForUVBB Model only Remove UV control module with UV lamp by lifting the control module straight up from mou
34. ng Sump 10 20 151120 8 Indicator LED fw 17 Sleeve Quartz 20 36003035 3 Sleeve Channeling 5 5 44301007 9 Fuse 1A Type 31000006 with Rings 20 10 Module UV Control 20 40200116 18 Rod Safety Plunger 22401015 4 Gasket Sleeve 36099205 11 Screw 6 32 x 3 8 32701063 19 Spacer Bushing 10 20 22401016 5 Head UV 10 20 36005701 12 Screw 10 x 3 4 32701006 20 Head Filter 3 4 10 20 154017 6 Mounting Bracket 31910101 13 Screw 14 1 32701060 21 Filter Sediment 20 5 micron 33003033 1 Sump 14 Washer 14 Nylon 32800031 22 Nipple 3 4 33601023 Mounting Bracket 31910201 15 Ring Quartz Sleeve 34202021 23 Filter Carbon Block 20 EPM 33004022 2 Sump Standard 2 10 micron 6B Mounting Bracket 31910301 n s Wrench Sump 10 20 150295 3 Sump t Consult Factory to determine part number for applications other than 120V 60hz not shown UVBB SERIES SYSTEM ASSEMBLY AND ACTIVATION PROCEDURES PREPARATION INSPECT ALL PARTS NOTE Read Mounting Bracket and System Plumbing Installation instructions on Page 1 and all instructions on this page before installing system UVBB SERIES UVBB Ultraviolet System Ultraviolet Lamp 20 in packing tube Quartz Sleeve 22 in packing tube Mounting Screws 2 4 pieces varies with model Installation Manual and Owners Guide Sump Wrench 20 NOTE See Page 7 for UVBB detailed parts brea
35. nted component is found defective the manufacturer at its sole option will repair or replace such Product or warranted component or will refund all or a pro rata portion of the Product s purchase price You pay only freight for repaired or replaced parts from our factory and local dealer charges including but not limited to labor charges travel and transportation expenses and handling fees This warranty shall not apply to any part damaged by accident fire flood freezing Act of God bacterial attack filter fouling and or scaling sediment misapplication neglect alteration installation or operation contrary to our printed instructions or by use of accessories or components which do not meet PURA specifications If the drinking water system is modified by anyone other than an authorized PURA dealer the warranty shall be void ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE PERIOD SPECIFIED ABOVE FOR PRODUCT AND COMPONENTS DESCRIBED IN THIS LIMITED WARRANTY As a manufacturer we do not know the characteristics of your water supply The quality of water supplies may vary seasonally or over a period of time Your water usage may vary as well Water characteristics can also change if the Product is moved to a new location For these reasons we assume no liability for the determination of the proper equipment necessary to meet your requiremen
36. nting bracket The four pin socket is attached to the UV control module by a short cable that allows for correct insertion depth Grasp UV lamp and four pin socket firmly and separate lamp from connector c ForUV1 and Addon Models Only Remove UV lamp by gently lifting the cable connecting the four pin Socket to the UV lamp Grasp UV lamp and four pin Socket firmly and separate lamp from connector During replacement be sure UV lamp is inserted as far as possible into the quartz sleeve NOTE Theinside of quartz sleeve must be completely dry before installing the replacement UV lamp NOTE Hold replacement UV lamp by the ceramic ends only Do not touch the glass Clean glass with isopropyl alcohol if necessary T Install the replacement UV lamp by reversing steps 5 and 6 of this procedure 16 2008 WATERGROUP INC Manufactured by WaterGroup Companies Inc PURA LIMITED WARRANTY Subject to the conditions and limitations described below the manufacturer warrants its ultraviolet drinking water systems Product excluding filters when installed in accordance with PURA specifications to be free from defects in materials and workmanship under normal use within the operating specifications for a period of 3 years from the date of purchase with the exception ofthe electrical components which are warranted for 1 year This warranty shall apply only to the original end user of the Product If the Product or any warra
37. oes not unplug system verify the UV lamp is securely plugged into four pin socket and repeat this Step NOTE UV lamp should remain on at all times during use because repeated starting of UV lamp shortens lamp life and UV lamp requires a warm up period of 1 2 minutes 2 Turn on water supply and check for leaks 3 Flush system connectors and water lines for several minutes to remove carbon fines NOTE When an ultraviolet water treatment system is unused for several hours water within system could become warm This is a normal condition To cool the water dispense water from system NOTE System is now ready for use Service Requirements Recommended Service Intervals To ensure the system operates at its optimum level certain routine maintenance must be performed Frequency of maintenance performance will depend on source water quality and level of system usage CLEAN Each time filters are replaced DISINFECT At least once a year UV lamp 10 Change Annually Quartz Sleeve 10 Clean when changing filters Replace only if damaged or cannot be cleaned by non abrasive methods Filter Normal life 4 6 months Filter life will vary due to water conditions A reduced flow rate or deteriorating water quality indicates that filters must be changed 10 RR e RRR Ne e 6 6 6 0 0 0 RK KK Mete ete ete e e e
38. r supply using proper fittings and thread sealing tape 3 Connect outlet of UV system to water distribution lines using proper fittings and thread sealing tape 4 See appropriate System Assembly and Activation Procedures for your system to complete installation UVB SERIES SYSTEM ASSEMBLY AND ACTIVATION PROCEDURES PREPARATION INSPECT ALL PARTS NOTE Read Mounting Bracket and System Plumbing Installation instructions on Page 1 and all instructions on this page before installing system UVB SERIES UVB Ultraviolet System Ultraviolet Lamp 11 in packing tube Quartz Sleeve 11 in packing tube Mounting Screws 2 4 pieces varies with model Installation Manual and Owners Guide Sump Wrench 10 20 NOTE See Page 3 for UVB detailed parts breakdown Refer to the label affixed to the mounting bracket to identify filter s to be installed with UV module INSTALL QUARTZ SLEEVE AND DISINFECT SYSTEM CAUTION QUARTZ SLEEVE IS VERY FRAGILE For safety wear a protective glove when handling quartz sleeve Do not touch quartz sleeve or UV lamp with bare hands Fingerprints will reduce the effectiveness of the light NOTE All Items refer to Figure 1 1 Remove Sump Item 1 from UV Head Item 5 NOTE Do not remove protective plastic bag from quartz sleeve until so instructed 2 Remove Quartz Sleeve Item 17 from packing tube While holding middle of quartz sleeve with one hand slide protective
39. s A reduced flow rate or deteriorating water quality indicates that filters must be changed UVBB 1 UV COMPONENTS UVBB 3 CARBON FILTER COMPONENTS Figure3 Exploded Schematic PURA UVBB Series Parts List UVBB Series Item Description Part No Item Description Part No Item Description Part No 1 Sump UV 20 BB 153070 6A Mounting Bracket 31910202 15 O Ring Quartz Sleeve BB 2 34202022 2 O Ring Sump BB 151122 2 Sump BB 16 Lamp UV 20 36002018 Sleeve Teflon Delivery BB 44301015 6B Mounting Bracket 31910302 17 Sleeve Quartz 22 36003036 c w clamp 3 Sump BB with Rings 4 Sleeve Quartz Adapter 44301009 7 Swith Safety 18 Sleeve BB 20 S S 36099105 sl win Rings 8 Indicator LED 19 Nipple 1 1 2 33601024 n s E MERE 34202022 9 Fuse 1A Type 31 999099 20 Head Filter 1 1 2 BB 154078 eeve Inner 2 pieces 10 Module UV Control BB 44302403 21 Filter Sediment 20 33003117 n s O Ring Quartz Adapter 34201039 41 Screw 6 32 x 3 8 32701063 5 micron BB Sleeve Outer 2 pieces n Eod UV H0 BB AE 12 Screw 14 x 1 32701060 22 Filter Carbon Block 20 33004015 13 Screw 5 16 x 1 1 4 32701074 10 micron BB EPM 6 Un Bp 31910102 44 washer 5 16 32800029 n s Wrench Sump 20 BB 144368 23 RedTape
40. s Item 9 NOTE Toinstall a system in SERIES as shown in Figure 5 connect all heads together with nipples prior to installing heads on Rack System 4 Plumb heads for specific configuration using proper fittings and thread sealing tape NOTE See Page 6 for UVBB Assembly and Activation Procedures to complete installation Figure 4 Rack Components and Location SERIES mI tL i PARALLEL tt PARALLEL TO SERIES W 1 LLL LL Figure 5 Module Attachment Points Figure 6 UVBB Rack System Configurations DATE INSTALLED SYSTEM OUTPUT RATING LPM GPM CONFIGURATION SERIES SERIES TO PARALLEL PARALLEL PARALLEL TO SERIES MODULE 1 PURA PART NUMBER MODULE 2 PURA PART NUMBER MODULE 3 PURA PART NUMBER MODULE 4 TYPE PURA PART NUMBER Table 1 System Configuration and Component Parts Initial Installation UV1 SERIES SYSTEM ASSEMBLY AND ACTIVATION PROCEDURE PREPARTATION INSPECT ALL PARTS NOTE Read Mounting Bracket and System Plumbing Installation instructions on Page 1 and all instru
41. ts and we do not authorize others to assume such obligations for us Further we assume no liability and extend no warranties expressed or implied for the use ofthis product with a water source that does not meet the Conditions For Use in the Installation Guide amp Owner s Manual THE MANUFACTURER S OBLIGATIONS UNDER THIS WARRANTY ARE LIMITED TO THE REPAIR OR REPLACEMENT OF THE FAILED PRODUCT OR COMPONENTS OR THE REFUND OF THE PURCHASE PRICE AT WATERGROUP S OPTION AND WE ASSUME NO LIABILITY WHATSOEVER FOR DIRECT INDIRECT INCIDENTAL CONSEQUENTIAL SPECIAL GENERAL OR OTHER DAMAGES WHETHER FROM CORROSION OR OTHER CAUSES Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Similarly some states do not allow exclusion of incidental or consequential damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Consult your authorized PURA Dealer for warranty and service information WaterGroup Inc WaterGroup Companies Inc For parts and service contact 193 Osborne Road 580 Park Street 265 Industrial Road Fridley MN Regina SK P O Box 5000 U S A 55432 Canada S4N 5A9 Cambridge ON Canada N3H 5N3 U S Patent 46 740 235 2008 WATERGROUP INC Manufactured by WaterGroup Companies Inc
42. ttom of filter NOTE Refer to Exploded Schematic for your system to ensure each filter is installed in the correct position NOTE For UVB and UV1 Models only Refer to the Exploded Schematic to ensure proper position of Teflon Sleeve removed in Cleaning Procedure 2 Install the filters into the appropriate sump Hold filter by its protective plastic bag and insert the filter into the sump CAUTION For UVBB Model only Be sure sump with metal liner is installed onto UV head CAUTION TIGHTEN SUMPS BY HAND ONLY Do not use tools as they will over tighten and may damage sump Take care not to cut or pinch rings or gaskets Use sump wrench for removal only 3 Slide bag from filter and discard Replace each sump as each filter is installed 4 Plug system into electrical outlet Turn on water supply and check for leaks Flush system for several minutes to remove carbon fines ROUTINE MAINTENANCE UV LAMP REPLACEMENT PROCEDURE NOTE Refer to individual System Assembly and Activation Procedures to identify specific components matching the descriptions shown in this procedure 1 Disconnect system from electrical outlet 2 Shutfeed water supply valve and open downstream faucet to relieve system pressure CAUTION Do not attempt to remove sumps until water flow stops This reduces pressure inside the system so sumps may be safely removed CAUTION Use care when sanitizing UV head Do not get the UV control modu
43. tubing Sharp turns case tubing to flex and deform which reduces flow capacity and may increase lateral stress on the fittings causing leakage ADDON SERIES SYSTEM ASSEMBLY AND ACTIVATION PROCEDURES CONT D INSTALL TUBING cont d QUICK CONNECT FITTINGS Fittings consist of two parts a Body and a collet 1 To install a tube push it through Collet until it seats firmly at the bottom of fitting Figure 8 A and 8 B 2 Toremove a tube push and hold Collet against Body while pulling tube out Figure 8 C TUBE O RINGS ZZ yS R o coust 177 M BODY A Push tube through Collet into Body Ua Tube must seat firmly at bottom of fitting d 4 AUR C Push Collet against Body to release tube Figure 8 How to Use Quick Connect Fittings ACTIVATE SYSTEM CAUTION Verify that inlet and outlet ports are connected to appropriate inlet outlet pipes see Figure 8 WARNING NEVER LOOK DIRECTLY AT A LIGHTED UV LAMP ALWAYS LOOK AT LAMP THROUGH FINISH CAP ONLY 1 Plug system into an electrical outlet The finish cap should illuminate within one minute indicating UV lamp is on If it does not unplug system verify the UV lamp is securely plugged into four pin socket and repeat this Step NOTE UV lamp should remain on at all times during use because repe