ICI Installation Manual

image

Contents

1. Branch ID Pump No xcessive Flow Overflow 10 8 hold Branch No i Delay mins 1 e Master Valve CNE ENO Course Location r Rain Bird Messenger TM Page Pager Group Message 0 v Poll ICSEN Status OK Cancel Name the entry for easy identification Set the Address to the ICSEN address from the barcode label Set the Box number if shown to the ICI interface Set Group to the wire path to which the ICSEN is attached ICSEN Installation Guide 25 26 RAINS BIRD Use the Units Per Pulse Calculator to calculate or directly enter the Gallons per Pulse value Configure Flo Watch and Pump Monitor using normal Rain Bird central control procedures To verify ICGEN communication use the Poll ICSEN Status button as shown above ICSEN Installation Guide ICSEN Specifications Operating Temperature Storage Temperature Operating Humidity Storage Humidity Sensor Types Supported Voltage Current Contact Closure Pulse Counting Pulses in 10 Seconds Pulses per Second IC System Field Wiring Voltage ICSEN Installation Guide RAINS BIRD 14 F to 125 F 10 C to 5190 40 F to 150 F 402C to 65 5 C 75 max at 40 F to 108 F 4 4 C to 42 2 C 75 max at 40 F to 108 F 4 4 C to 42 2 C 0 10VDC 4 20mA DC 50 duty cycle 1kHz max 50 duty cycle 1kHz max 50 duty cycle 1kHz max 26 28 VAC ma
2. Interface Device This section explains how to install and configure the ICSEN device gt gt RRR NOTE The ICSEN device must be installed in compliance with all electrical codes NOTE The ICSEN device does not provide power for sensor devices The IC System wire path MAY NOT be used to power sensor devices Sensor devices requiring power must be connected to a suitable power source separate from the IC System wire path NOTE The installation of the ICSEN device should be performed with the IC System wire path unpowered NOTE For the first two minutes after the wire path has been reactivated there will not be any operation or response from the field ICSEN devices WARNING Field wire paths must be kept separate from other wire paths Do not connect the field wires together from different output group wire paths on the ICI Integrated Control Interface WARNING This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety WARNING Children should be supervised to ensure that they do not play with the appliance ICSEN Installation Guide 3 RAINS BIRD Compliance Information C US LISTED E41049 This device complies with Part 15 of the FCC rules subject to the following two condi
3. the Rain Can No using the buttons at the top of the dialog Set Box number to the correct ICI Set Group number to the ICI wire path to which the ICSEN is ICSEN Installation Guide 21 22 RAINS BIRD connected Set the Address to the ICSEN barcode address value Other options are set as normally for the Rain Bird central control software To verify ICGEN communication use the Poll ICSEN Status button as shown above ICSEN Installation Guide Configure Flo Watc RAINS BIRD h Sensors ICSEN Flo Watch sensors should be connected to flow sensors producing a series of pulses at a rate proportional to flow rate Pulse transmitters can be used to scale pulse rates appropriately for ICSEN ICSEN can handle input pulses at a maximum rate of 1kHz 1000 pulses second at 50 duty cycle To add a new Flo Watch sensor select Sensors and the Pulse Sensor tool a B Print Office Password FloManag Sensors Messenger Decoder Sensors x ICSEN Installation Guide 23 RAINY BIRD 2 Inthe Pulse Sensor Monitor window click the icon to add a new sensor through the Flow Sensor Setup dialog Pulse Sensor Monitor Pulse Sensors 24 ICSEN Installation Guide RAINY BIRD Sensor ID r Sensor Calibration Units Per Pulse Calculator Group Address sd Gallons per Pulse e Pump Monitor l FloWatch tm No Action
4. RAINS BIRD IC System ICSEN Sensor Interface Installation Guide Ulf August 2015 RAINS BIRD IMPORTANT NOTES INSTALLING THE ICSEN Integrated Control Sensor Interface Device 0000r0rnnnnvevenensnansrnrvovevnsnsnsnsnsove ven nsnsnsnsosn veve nensnsnsnsoveve ven nnsnsnsevevevenensnsnsnsevenenenn 3 Compliance Information gt gt sssasmmassmmmsmmesesneenmmeaneateansseansrateranssatetnn 4 ET EEG EE 5 Verify Contents of the Packing BOX reneamsenmemeneimnnjvveniedin ieirik naa 6 Choose Location to Install the ICSEN iccssntanctntesnsenninsasesnnenntonssntanataverntiersinsanctntasntenntasds 6 Gather Installation TONS sara nee asian iets ene 7 Connect IC System Field Wiring c cccccccccesesesecesesesesesesescsescsesesescstetssesesevsveseseveveseneces 7 Connect SENSO SOUCO NN E TER 9 Complete Installation sss iien EE 12 Configure Rain Bird Central Control Software aarrrnnnnnnnnnnnnannnrrnnnnnnnnnnnrnnnnnrrennnnnnnnnnn 13 Configure Programmable Sensors sara ANG 16 Configure Rain Watch SONSONS soi vcusisesiciasinins useiataditinedbensisesieutatnctnivatniededdtonudbnncininsiniantos 19 Configure Flo Watch S nSors cccsccccssessssesesesesesesssscsesesesesesussssssesesesesesesesicseseseseses 23 ISEN SETTE cause vncunacouncusncuiscnpacuidcusncuicnsddnideusncniendaduidensacninendddnisensaniasmcnises 27 2 ICSEN Installation Guide RAINS BIRD IMPORTANT NOTES INSTALLING THE ICSEN Integrated Control Sensor
5. The ICSEN device monitors the state of an external sensor of a certain type The sensor state or value can be used in Rain Bird central control software to adjust irrigation report flow etc Although various types of sensors may be connected the connections are made through the same two ICSEN inputs SENSOR and SENSOR CAUTION All electrical wiring connections and wiring runs must be made according to local building codes The drawing below shows a typical ICSEN application for Rain Can sensing The SENSOR and SENSOR inputs are connected to the Rain Can outputs To ICI i ICSEN F69400 TIPPING BUCKET Rain Can Mode Pulse RAIN CAN Red Red with White Strip Black Black with White Stripe ICSEN Installation Guide 9 RAINS BIRD The drawing below shows a typical ICSEN application for flow sensing The SENSOR and SENSOR inputs are connected to the flow sensor outputs To ICI Ty 10 ICSEN FlowM eter Mode Pulses Data Industrial in 10 Seconds SFS150P FlowSensor Black with White Stripe The ICSEN device should arrive from the factory with wire ends stripped If not strip approximately 1 of insulation from each wire Take care not to score the copper strands Strip approximately 1 of insulation from each external connection wire to be spliced with ICSEN Take care not to score copper conductors Connect the ICSEN red with white stripe SENSOR wire to appropriate sensor output
6. ation with easy access to external sensor power needed by your sensor if any NOTE This controller must be installed in compliance with all electrical codes ICSEN Installation Guide RAINS BIRD Gather Installation Tools a genie i Wire strippers a A Rain Bird DBRY splice kits 4 total splices 3 Connect IC System Field Wiring 1 The ICSEN device should arrive from the factory with wire ends stripped If not strip approximately 1 of insulation from each wire Take care not to score the copper strands 2 Strip approximately 1 of insulation from each MAXI wire IC System field wiring to be spliced with ICSEN Take care not to score copper conductor 3 Connect the ICSEN red wire to the MAXI red wire Do not connect the ICSEN red with white stripe wire at this step The ICSEN MAXI connection should be solid red ICSEN Installation Guide RAINS BIRD 4 Connect the ICSEN black wire to the MAXI black wire Do not connect the ICSEN black with white stripe wire at this step The ICSEN MAXI connection should be solid black 5 Add suitable protection to the splices For installation in a valve box use a Rain Bird DBRY splice kit for each splice securing the splice with the wire nut then inserting the splice completely into the grease cap Note that grease caps are single use do not attempt to reuse them 8 ICSEN Installation Guide RAINS BIRD Connect Sensor Source
7. int Office Password FloManag t Sensors MassengerDecoder 16 ICSEN Installation Guide RAINY BIRD 2 Click the icon to add a new sensor through the Sensor Setup dialog where you will enter the Name Box interface number Group Address and Type P cms mm to BS MTT EEA Comment Sensor Setup pe Som Box i Address Group i Sensor Type Power Source Interrupt System Enabled 7 High Threshold Ovols gt C Ab rolf IF Low Threshold Ovos gt 7 ci Poll ICSEN Status Ok Cancel Name the entry for easy identification Set the Address to the ICSEN address from the barcode label Set the Box number if shown to the ICI Set Group to the wire path to which the ICSEN is attached Set the Sensor Type based on the characteristics of the sensor connected to the ICSEN For example a flow meter ICSEN Installation Guide 17 RAINS BIRD should usually be set for Number of Pulses in 10 Seconds resulting in a rate of flow based on the number of gallons or liters or cubic meters per pulse 3 To verify ICSEN communication use the Poll ICSEN Status button ICSEN Status ICSEN Address Box 1 Group 1 Address bladd ICSEN Status Status Cancel Click Poll ICSEN Status should indicate OK or No Response If No Response check wire path group address and make sure that ICI power is applied for two minutes before testi
8. low the port number and box number are not critical but the ICI should be selected with a checkmark and the port should not be Demo System Settings ese l 60HZ C 50HZ ed Port JB Type f I Rain Sensor On Line COM14 Direct r C RainWatch x COME Direct Weather Station 1 COM3 NotFound Weather Station 2 oo Station 3 Mi If no ICI is configured refer to the IC System Installation instructions to complete this step 14 ICSEN Installation Guide RAINS BIRD 3 There are three classes of sensors that you may wish to add to Rain Bird central control programmable sensors including flow level contact closure or voltage Rain Watch sensors and Flo Watch sensors Programmable sensors can be used for monitoring applications and to trigger central control events like starting a program Rain Watch sensors are used specifically to monitor for rainfall and pause or stop irrigation based on detected rain Flo Watch sensors are used for flow monitoring and can be used to detect excessive flow conditions due to pipe breaks or other faults A single ICSEN should not be configured for multiple sensor classes Doing so will cause operational problems ICSEN Installation Guide 15 RAINY BIRD Configure Programmable Sensors 1 To add a new programmable sensor select Sensors then the Programmable Sensor tool as shown below DN gt ND Pr
9. ng 18 ICSEN Installation Guide RAINY BIRD Configure Rain Watch Sensors 1 ICSEN Rain Watch sensors should be connected to contact closure style Rain Cans To add a new Rain Watch sensor open System Settings C gt Danag 830 p EJ Program DryRun Monitor L FloGraph and check the RainWatch checkbox ICSEN Installation Guide RAINY BIRD System Settings ean EE 60HZ 50HZ D Pot YB Type al I Rain Sensor On Line COM14 Direct AC Painwatch X COME Direct Weather Station 1 COM3 NotFound Weather Station 2 Weather Station 3 ie ign port to selected device Por t COM Direct Assign ssn E If RainWatch is already active click the button to open the Rain Can Definition dialog 20 ICSEN Installation Guide RAINY BIRD 2 Use the Rain Can Definition window to set the Rain Can Number Box interface number Group number and ICSEN address as shown in the example below Rain Can Definition Rain Can No Ea 2 3 4 x Box MEEL Group Address 1 B14D5 Rain Can System Response v Rainwatch Window 6 hours Rain Can 0 01 in pulse Pause Threshold 0 1 inches Pause Time 60 minutes Rain Shutdown Threshold jos inches Rain Shutdown Time 124 hours Poll ICSEN Status Up to four Rain Cans may be defined in the system Configuration of each is accomplished by first selecting
10. tions 1 This device may not cause harmful interference and C 2 This device must accept any interference received including interference that may cause undesired operation This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations EN61000 6 1 1997 Class B EN61000 3 2 EN61000 3 3 EN61000 6 3 1996 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 EN61000 4 6 EN61000 4 8 EN61000 4 11 EN 60335 1 2010 Safety of household and similar electrical appliances 4 ICSEN Installation Guide RAINS BIRD Installation Checklist The following steps are recommended in order to properly install the ICSEN device For your convenience a check off box has been provided for each step Q Q Verify the contents of the packing box Choose a location to install the ICSEN It is advisable for serviceability to install the ICSEN in a valve box near the target sensor or immediately adjacent to the sensor Gather installation tools Connect IC System field wiring Connect sensor source Complete the installation ICSEN Installation Guide 5 RAINY BIRD Verify Contents of the Packing Box ICSEN Device Choose Location to Install the ICSEN Choose a location minimizing wiring length between ICSEN and target sensor Ideally the ICSEN should connect directly to the sensor output leads Choose a location with easy access to the IC System wire path Choose a loc
11. wire Connect the ICSEN black with white stripe SENSOR wire to appropriate sensor output wire Add suitable protection to the splices For installation in a valve box use a Rain Bird DBRY splice kit for each splice securing the splice with the wire nut then inserting the splice completely into the grease cap Note that grease ICSEN Installation Guide caps are single use do not attempt to reuse them ICSEN Installation Guide RAINY BIRD 11 RAINS BIRD Complete Installation Double check safety of all connections Assure that electrical codes have been followed and that no exposed wire ends are present Assure that ICSEN and the connections are suitably protected from surrounding environment Note the ICSEN address from the barcode label or use the tear off copy of the label for entry into Rain Bird central control software If using a sensor with external power supply apply sensor power Apply power to the IC System wire path Allow two 2 minutes for all IC System devices on the wire path to power up before performing operations ICSEN Installation Guide RAINY BIRD Configure Rain Bird Central Control Software 1 Launch Rain Bird Central Control software and select System Settings to check ICI configuration p FloGraph ICSEN Installation Guide 13 RAINY BIRD 2 Verify that the System Settings dialog box shows a configured ICI interface as shown be
12. x 27

Download Pdf Manuals

image

Related Search

Related Contents

COBY electronic DVD765 User's Manual  User Guide Adaption_IT.qxd:User Guide Adaption.qxd  Port Designs BERLIN  Benutzerhandbuch  Vosstronics EasyDog  BA COM Uni3, V1, 105x210 mm, 1c, Entwurf 01, CS2.indd  Questions que les membres des conseils d  Samsung LA26C360E1M User Manual  Agilent Technologies E6432A User's Manual  