1. Upgrade Port License Check for Updates Navigation Bar Machine List window CNC Machine Name State Operation Fort Settings File Send Progress File Receive Progress Machine Type samien Off in ARA Osytes Receives NN The default machine Sample 1 is listed and is shown as offline When machines are setup on AxDNC you will see 1 Page ao ob ae SS CNC Machine Name Current state On Line or Off Line Operation Port Settings File Send Progress File Receive Progress Machine Type Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca 16 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc Adding a Machine Before you can add a machine to which you can connect you must first install the machine AxDNC will support direct serial connected machines However the purpose of this Quick Start Manual is to connect AXDNC to the Mx1053 universal network interface via TCP IP Once you have installed the Mx1053 UNI and confirmed that the interface is set up and visible on the network you can add the Mx1053 equipped machine tool to AxDNC NOTE If you are running the unregistered evaluation copy of AXDNC a sample machine already exists The sample cannot be deleted in this mode Therefore you will modify the existing Sample machine record If you have a multiport license then you can create a
2. Rename File Edit EventLogs M em P gt CNC Machine Name Ysamiet Add Delete Edit Ctrl A Del Ctril E Rename Copy Backup Settings Restore Settings Show Machine Rename the machine to whatever you want Do not use spaces or special characters such as underlines 5 N Rename N Current machine name Sample New machine name Fanuct5T Click OK Machine Type Mill Lathe Etc Mill Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 22 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc A Ax DNC V1 1 0 6 Unregistered Version used are 1 30 1 Port License File Edit EventLogs Machine Connection Operation Help a TOLER CNC Machine Name State Operation Port Settings File Send Progress File Receive Progress Machine Type J FANUCIST Fin Remote idle 10 10 1 39 4444 0 Bytes Received MILL E The new name is now displayed You have now setup a machine using a Mx1053 UNI connecting to AXxDNC software Details of settings can be found in the full user manuals for the respective software or devices This completes the installation and basic configuration of AXDNC Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca P
3. INC SOFTWARE PRODUCT LICENSE The SOFTWARE PRODUCT is protected by copyright laws and international copyright treaties as well as other intellectual property laws and treaties The SOFTWARE PRODUCT is licensed not sold If you accept the terms of the agreement dick I Agree to continue You must accept the agreement to install AxDNC Astrix Networks Inc Installer Please review the End User License Agreement content To continue click I Agree button You will be presented with the file location window Choose Install Location ASTVix Choose the folder in which to install AxDNC networks Setup will install AxDNC in the following folder To install in a different folder dick Browse and select another folder Click Install to start the installation Destination Folder C Program Files x86 AxDNC Space required 17 7MB Space available 30 1GB The Destination Folder contains the Default file location This can be changed by clicking on the Browse button and selecting a new file location creating a new folder if desired and clicking OK Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 12 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc d Config Msi gt ae Documents and Settings gt bb easy rsa gy found 000 M GameHouse Games i db inetpub ad Intel J Intuit I
4. L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 19 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc E fai Machine Properties for Samplel lem SerialPort Files Send Receive Delay Timers TCP IP Options Commands Messages Directories Primary send Folders for files to be sent to the machine CA Secondary send Folders for files to be sent to the machine ie NC CNC NWD leave blank for no EXT If there is only one send folder used then set both the primary and secondary send folder to the same folder If there is only one receive folder used then set both the primary and secondary receive folder to the same folder Set the default file extension used for NC part program files r z lai Machine Properties for Sample1 neo Serial Port Files Send Receive Delay Timers TCP IP Options Commands Messages A Set EDE on send f CRILF LF CR LFYCR LFICRCR CRCRILF f None Start of program End of progra Skip lines that start with i co Po Transmit before sending Tile Skip lines that contain ASCII Chart ASCII Chart Translations Transmit after sending file Set the correct delimiters used in the existing NC part program files Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 20 of 25 ISO9000 DOCs M100728F UNI Pictori
5. new machine For this quick start manual you will modify the Sample Click the Machine Connection menu item and then click Edit Machine Connection Operation Help j Add Ctr A i Delete Del Edit Ctrl E E Rename fie E coy Backup Settings p The machine Properties window will appear cA Machine Properties for Samplel AAAA l Serial Port Files Send Receive Delay Timers TCPIP Options Commands Messages Serial port Machine protocols e Noa o Connection parameters Software control Baud rate 350 an Buffer Size 1024 Special Protocol Data bits a Bits No Protocol l send Type Line Parity None ha XON J XOFF Stop bits 1 stop Bit Serial data flow control None DC1 DC3 Wait for XON Cancel Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 17 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc Select the TCP IP tab displayed across the top of the Properties Window A Machine Properties for Samplel 0020200000 l m i Serial Port Files Send Receive Delay Timers TCP IP Options Commands Messages TCPAP Information TEP IP Address 0 0 0 0 Port rr 2 Use TCP Use TCP Poll Keep Alive Foll interwal 2000 ms Reconnect Interval 10 Secs Cancel There are 6 parameters w
6. 0 Requesting setting 1 A9150 Serial Forts Settings Unavailable AHS 2200 Requesting setting 2 l AHS 2200 Requesting setting 3 COM Pott CNC ONC WAND AeHS2200 configuration receiwed BAUD 49750 Requesting setting 1 260 J500 S600 A9150 not availabl Sarena Fma Flow Contro Hw Clsw C HW Swe Hw CSW Current File Status Configuration recetved The IP address is now displayed for the device to be setup Note the IP address for setup in AxDNC AgHS2200 Serial Port Settings COM Fort WAND BAUD 3600 Flow Contro Ha Sw CNC S600 m Hw O sw E Configure the settings shown above to set the serial port settings for this Mx1053 Use Config gt Write All to save any changes to the Mx1053 Click exit when finished to disconnect to the board Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 10 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc Installing AXDNC Locate the AxDNC installer file 9 rP r P P P P J s Computer Local Dik C gt Users Downloads o OO e File Edit View Tools Help Organize Open Share with Burn New folder Sr Favorites Name Date modified Type Size 5 Recently Changed EX axDNC Setupli06ee 442 10 2010947AM Application 6 948KB P pp E Phir vinan o ADMON AM WinRAR 7D arhi ATIATI ER Double Cli
7. 0 COM Pi x93150 BAL MAC Address O0 20 44 9F Ce 6 Hast Hame YOUR Forrr Flow Cont IF For Lantronis Network Settings mis Click Config gt Read gt All The status window will refresh and the device will respond in the list Note This will fail to connect to the AXHS2200 if other application is currently connected to this machine s 4444 port such as AXDNC You must disconnect or turn off the other application in order to configure the board Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 9 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc oe a a ee Exit File Contig Lantronia Network identification Lantronit Serial Port Settings COM Fort PACE Default DNC Host Default BAUD 9600 a00 115200 230000 Format Borne 1 BM ore ronis Network Settings Flow Control Hw Sw Hii Hw Sw HW os ak PAddess 10 4 oH me IF Port 1234 gt 1234 4444 4444 Host Name YOUR CHOICE MAC Address O0 20 44 9F C8 76 Net Mask 255 255 AKHS2200 Serial Port Settings COM Port WAND CHC BAUD S600 S600 Format OM ore 1 Lantronia Sending request for record 3 Lantronia Sending request for record 4 low Control Hw Sw Hw sw one Lantronis Sending request for record 5 Lantronix configuration recerved i AsHS220
8. 3 see Item 3 below 18 24 VDC Mx1053 Terminal Block for 18 24 VDC or 5VDC Option J7 8 Jumper Setting JP1 PWR DB9 COM1 Routes 24 VDC from Pin 9 of COM1 DB9 connector to provide power to the board Set jumper setting to OFF position if 24VDC is not being routed through DB9 Connector Note The option to use 24V on the CNC COM1port is available if 24VDC has been routed through the cable from the Control s RS232 connector Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 5 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc Option 3 External 5 VDC applied to the J7 Terminal Block Header located to the right of DB9 COMS serial port JP10 Reg ENBL does not need to be jumpered if 5VDC is to be used for the main power supply 6 Jumper Setting JP10 REG ENBL Enables the 5V DC Voltage Regulator to provide power to the Ethernet module Set jumper setting to OFF position 7 Terminal Block for Power J7 Route external power to provide power to the Mx1053 5 VDC on Pin 2 see Item 2 below and GND on Pin 3 see Item 3 below 18 24 VDC Mx1053 Terminal Block for 18 24 VDC or 5VDC Option J7 8 Jumper Setting JP1 PWR DB9 COM1 Routes 24 VDC from Pin 9 of COM1 DB9 connector to provide power to the board Set jumper setting to OFF position if 24VDC is not being routed through DB9 Connector
9. Mx1053 UNI Installation Manual Ax2200 Board The Universal Network Interface UNI is connected to a CNC control The UNI virtualizes the local serial port to an IP Address amp TCP port for remote access by Ethernet enabled software On the UNI COM1 is reserved for the serial port to the control also called Port D internally All ports have pin 9 capable of bringing in power 12 24VDC see Jumper JP33 The usual order of installation is as follows 1 With the power off install the UNI noting the power supply and cable connections Usually a serial cable will be supplied but in case it is not the DB9 on the UNI is like a standard PC serial port with pin 9 being a power input or output Mx1053 Universal Network Interface Rev 7 2 Connect the UNI RJ 45 Ethernet port up to a working CAT5 cable connected to the corporate LAN 3 On your DNC server load the supplied software a Install the AxHDU Utility from the CD and configure the Ax2200 then install i AxDNC Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 1 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc Connecting Power to the Mx1053 The Mx1053 UNI can be powered by three methods as follows 1 24 VDC from the COM1 CNC serial port on Pin 9 of the incoming female DB9 connector attached to the CNC data port of the control COM1 CNC Connec
10. Note The option to use 24V on the CNC COM1port is available if 24VDC has been routed through the cable from the Control s RS232 connector Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 6 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc Use AxHDU To Configure The UNIs Over the LAN Mx1053 Ax2200HS Configuration Summary 1 Ata PC station if the AxHDU High Speed Deployment Utility software is not already installed please install it now 2 Launch the AxHDU software 3 Click on the Search button to search for any Mx1053s on the Network The Mx1059 is shipped using DHCP mode 4 Click on the Device with the appropriate MAC address to highlight it and click on setup This will bring up a window that will provide information on the serial configuration of the Mx1053 and the Network information of the Ax2200HS device To change the IP address to a Static IP address uncheck Enable DHCP and insert the IP Address Subnet Mask and Gateway Address Note It is advisable to change the IP address from DHCP to a static IP address once it is seen on the network For the Serial port settings the CNC setting for the Ax2200HS is the only section that needs to be modified It needs to match the control that the Mx1053 is attached to Serial Baud Rate Data Bits Parity Bits Stop Bits Flow Control Wait for
11. XON o29Q29T0p After the Serial and Network Settings has been updated write the configuration to the Mx1053 by going to the top left of the configuration menu and clicking on Config gt Write gt All Click on Exit to leave the configuration menu 5 The serial and network configuration has now been completed Using the AXHDU Utility Go to Start gt Programs gt AXHDU and click on the menu item AxHDU Uninstaller RU AxHDU di AxOEE Manager di BarTender 9 3 BerBible Folder di Bomgar 4 Back Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 7 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc The UMI HS Deployment utility s search window will appear UMI HS Deployment Utility Version 1 0 4 Hetwork Options O0 20 44 9F 42 FF JJA4 10 10 1251 255 255 255 0 4444 O0 20 44 9F 45 B4 MACSIMOO 10 10 1 244 255 255 255 0 4444 00 20 44 9F C8 76 YOUR CHOICE 10 10 1 39 O0 20 44 9F FE 32 MACSIMOT 10 10 1 242 255 255 255 0 4444 00 20 44 56 3 65 56 WAC 205ip 248 10 10 1 248 256 255 2550 4444 Time out 5 Use Broadcasts Use IF Scars Network Adaptor 10 10 1 57 Ww MAC Address O0 1F 30 43 24 49 Search Time Devices Found D al Click on Search to poll the network for Ax2200 network modules attached to the Mx1053 UNI and display a list of devices found Identify the dev
12. age 23 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc Troubleshooting Q Why can t find the Ax2200HS on the network when do a Search using Broadcast A Use IP Scan to scan for a particular IP Range and identify the Lantronix device on the Ax2200HS 1 Open AxHDU a UMI HS Deployment Utility Version 1 0 4 Exit Tools 00 20 44 96 44 BC SISOHSW2 10 10 1 240 DHCP 4444 00 20 44 SF 42 FF JJR3 10 10 1 251 255 255 255 0 4444 00 20 44 B3 68 56 10 10 1 248 255 255 255 0 4444 i IP Scanner Settings xX Time out 5 IP Address Scan Range _ Use Broadcasts C Starting Address UselPScan 10 4 10 4 14 58 H lt Ending ddress gt IP Scan Settings z 5 OEEIEEIEGE Network Adaptor 00 1F 29 38 F0 1 E Status Search Time 0 Devices Found 3 Diagram H 1 AxHDU Using IP Scan 2 Default search configuration is to Use Broadcast Select Use IP Scan see Item 1 Diagram H 1 above The IP Scan Setting can now be selected Click on IP Scan Setting see ltem 2 Diagram H 1 above 3 The IP range can then be set to a particular range to search for a Lantronix device see Item 3 and 4 Diagram H 1 above For example if the local PC IP is set to 10 10 1 5 a Lantronix device could have been provided by the DHCP server for a range between 10 10 1 1 up to 10 10 1 255 The search can be expanded by modifying the start and end IP addresses 4 Cl
13. al Installation Manual MAI doc ES Machine Properties for Sano iim Serial Port Files Send Receive Delay Timers TCPAP Options Commands Messages Remote Commands UMI Send Commands Start End Enable Befi Send ae ienr Bune MXCLEAR E E Autoname IY Use Auto Naming cl E The remote call and remote request commands used on the target control must be duplicated in the fields indicated above on the Commands tab Remote Commands End File Send SEND File Receive RECV mm Reset RESET o Proper syntax is required for the DNC software to process a file punched from the control Click the OK button on the Machine Properties window Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 21 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc 0 1 Port License File Edit Event Logs Machine Connection Operation Help You will be returned to the AXDNC main window Click on the icon indicated by 1 This is the connect to machine icon It will grey out and the disconnect machine icon will become visible The machine will now change it s state from off line to In Remote The machine is now online To rename the listed machine from Sample to a name more relevant click on the Disconnect machine icon to take it offline Then click on Machine Connection gt
14. ck on the file AXDNC_Setup_x x x x exe If prompted by your security Open File Security Warning el The publisher could not be verified Are you sure you want to run this software Name Users tims Downloads AxDNC_Setup_1 1 0 6 exe Publisher Unknown Publisher Type Application From C Users tims Downloads AxDNC_ Setup_1 1 0 6 V Always ask before opening this file re This file does not have a valid digital signature that venfies its x publisher You should only run software from publishers you trust N How can decide what software to un Select the preferred language and click OK The Welcome setup screen will appear Welcome to the AxDNC Setup Wizard This wizard wil guide you through the installation of AxDNC it is recommended That you dose al other apobcadons befere starting Setup This wi makr it posse to update relevent system fies without having to reboot you Computer Chick Next to continue Click Next Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 11 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc The software license agreement window will appear A a rN Ast x Please review the license terms before installing AxDNC networks Press Page Down to see the rest of the agreement END USER LICENSE AGREEMENT FOR MEMEX AUTOMATION INC ASTRIX NETWORKS
15. dministrative Tools gt di BRC Tools di Burrrn Korr Help and Support 4 Back aaa A Search programs and files Hibernate gt File Edit Event Lo Edit EventLogs Machine Connection Operation Help ca mm Ff 7288 CNC Machine Name State Operation Port Setings Fie Send Progress Fie Receive Progress f JSampiet J OrrLine None _ Cont 9600 n 6 1 0 byics Recoves A Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 14 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc Menu Bar File Edit EventLogs Machine Connection Operation Help File Edit Event Loc View Edit Machine Protocols Event Logs Fo Ax DNC V1 1 0 6 Unr ae ersi 6 nreg Merion a I Eie Edit Trace Logs Machine Connectior Operation Ctri A Del Ctrl E CNC Machine Name 8 gs Sample Backup Settings Restore Settings Show Machine Operation Auto Start Machines Shut Down All Remote Machines Remote ON Remote OFF Launch AxFMServer Launch Multi Pol Launch AxFTPClient Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 15 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc Help Ax DNC Help Topics About Register
16. hich are available on the TCP IP tab view 1 TCP IP address 2 Port assignment Default port is 4444 3 Poll interval in milliseconds 1 1000 of a second Default is 2000 ms which is 2 seconds 4 Reconnect Interval in seconds Default 10 seconds 5 Use TCP 6 Use TCP Poll Keep Alive Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 18 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc la Machine Properties for Samplel bi sa Serial Fort Files Send Receive Delay Timers TCP IP Options Commands Messages TCPAP Information TCP IP Address 10 10 1 39 Port rr 7 Use TCP Poll Keep Alive Foll interwal 2000 ms Reconnect Interval 10 secs in as The 6 parameters can now be populated on the TCP IP tab view 1 TCP IP address the address reported in the UMI deployment utility which in this case was 10 10 1 39 2 Port assignment Default port is 4444 3 Poll interval in milliseconds 1 1000 of a second Default is 2000 ms which is 2 seconds Reconnect Interval in seconds Default 10 seconds Use TCP check marked ame 6 Use TCP Poll Keep Alive unchecked unless network timeouts are a problem Before the machine setup is complete the following tabs need to be populated Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada
17. ice to be configured on the Device list by comparing the MAC address display to the one printed on the Mx1053 Silver Lantronix module Click on the device on the list and click on Setup button to open its configuration window Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 8 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc The Setup utility window appears ee a o S Exit File Config Lantronis Network Identification Lantronis Serial Port Settings COM Fort FACE Default DNC Host Default BAUD S600 S600 115200 230000 MAC Address O0 20 44 9F CA 76 Format A Mone l Sore Flow Control Hw Sa Hii Hiw Su Hi a IP PortH 1234 1234 4444 ddd Host Mame YOUR CHOICE Lantronia Network Settings IF ddress 10 10A 1s 39S Net Mask 2556 255 255 4 255 2 AHS 2200 Serial Port Settings COM Port WAND CHC Enable DHCP BAUD 9600 38400 b AHS 2200 Attempting to connect ta 10 10 1 39 AHS 2200 Requesting setting 1 Flow Contro Hw Sw nw sw E Timeout occured Gateway 0E gl gle ae 429750 Serial Ports Settings COM Port CHC DNC WARD BAUD 9600 9600 S600 Flow Contro Hw Swe OTH Swe Hw Si Status Timeout occured beme Setup Utility ow lt o d Exit File Config Lantronix Lantron Hs270
18. ick on Set see Item 5 Diagram H 1 above to accept the settings and click on Exit see Item 6 Diagram K 1 above to return to the main AXHDU window 5 At this point click on Search to initiate a poll of the Lantronix devices on the network based on the IP address provided in IP Scan Settings Once the search has been completed a list of the Lantronix devices will be shown under the Device List Choose the appropriate device by referring back to either the MAC address of the device or the unique Hostname given to the device Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 24 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc EME AUTOMATION Memex Automation Inc 200 3425 Harvester Rd Burlington Ontario Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca support memex ca 905 635 3041 sales memex ca 905 635 3043 Thank you for using Memex products Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 25 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc
19. nstalling ASM XX Please wait while AxDNC is being installed networks Extract NetONCMsg dll 100 Extract AxDNCConfig ini 100 Extract Protocols ini 100 Extract Messages INI 100 Extract AXDNC dat 100 Extract Ax DNC exe 100 Extract AxUpdate exe 100 Extract AxDNCUpdate ris 100 Registering C Program Files x86 AxDNC DNCServer dll Registering C Program Files 86 AxDNC GenLib dll Astrix Mektworks Inc Installer You are presented with an installation progress window which displays the files being installed Once complete you will be presented with the following window Completing the AxDNC Setup Wizard AxDNC has been installed on your computer Click Finish to dose this wizard V Run AxDNC Click Finish to close the installer and run the AXDNC application for the first time Uncheck mark the Run AxDNC radio button if you do not want to run AxDNC at this time Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 13 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc Running AxDNC for the first time To run AxDNC click on the AxDNC icon created on your desktop P P Microsoft PowerPoint 2010 Wa Control Panel Uninstall _ Website Devices and Printers M AxOEE Manager ad BarTender 9 3 Default Programs a BerBible Folder a Bomgar A
20. ower options Please choose the option that best describes your scenario Option 1 24 VDC from the COM1 CNC serial port on Pin 9 of the incoming female DB9 connector attached to the CNC data port of the control COM1 CNC Connector 6 Jumper Setting JP10 REG ENBL Enables the 5V DC Voltage Regulator to provide power to the Ethernet module Set jumper setting to ON position 7 Terminal Block for Power J7 Do not connect any POWER to this connector 18 24 VDC Mx1053 Terminal Block for 18 24 VDC or 5VDC Option J7 8 Jumper Setting JP1 PWR DB9 COM1 Routes 24 VDC from Pin 9 of COM1 DB9 connector to provide power to the board Set jumper setting to ON position if routed through DB9 COM1 cable Note The option to use 24V on the CNC COM1port is available if 24VDC has been routed through the cable from the Control s RS232 connector Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 4 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc Option 2 External 18 24 VDC applied to the J7 Terminal Block Header located to the right of DB9 COMS serial port 6 Jumper Setting JP10 REG ENBL Enables the 5V DC Voltage Regulator to provide power to the Ethernet module Set jumper setting to ON position 7 Terminal Block for Power J7 Route external power to provide power to the Mx1053 18 to 24 VDC and GND on Pin
21. tor NOTE Use this option for Fanuc Controls 2 External 18 24 VDC applied to the J7 Terminal Block Header located to the right of DB9 COMS serial port 3 External 5 VDC applied to the J7 Terminal Block Header located to the right of DB9 COMS serial port JP 10 Reg ENBL does not need to be jumpered if 5VDC is to be used for the main power supply Warning Do not use both 5VDC and 18 to 24 VDC for external power Only one type must be used to power the board Warning Do not use both 24VDC from COM1 CNC serial port and external power Only one type must be used to power the board To set the jumper settings on the Mx1053 upon which the Ax2200HS has been placed follow the instructions 1 to 8 below Js 1 sabt bud 0 4 2 Steh i I a a nro ETHE RNET RESET ANAT a TT l __ OPT JPRS ONO U Dn MEMEX ETHERNET MODULE NET2ETR NET2ZCOM BTR2COM M sia ie E Ej nit gaga Mmmm 2 COMJ RJ arun as o Wma ummu Er nmo o lr s nines eg ais eee a te Gel eu recor o MINU Pe Td sel rue amp 3 pcom p conz H z mm mm N r a IZVDC 2 RESETABLE a nl en oe a wree eceturetew SELF COM2 3 FUSE 500 meo E ci S N 100111 JPI PWR DS9 CON Db i eo m Beeeeeeeeen Mx1053 Power and Jumper Setting 43 COMS oB9 JP33 N il Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fa
22. x 905 631 9640 www memex ca Page 2 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc 1 Jumper Setting JP31 and JP32 Set jumper setting to B position in order to route the com port of the Ethernet module to the COM1 CNC port see diagram below JPS1 JP32 Mx1053 Jumper Setting for JP31 and JP32 2 CNC COM1 A standard Fanuc DB9F to DB25M with 24V routed through pin 9 on the DB9 and pin 25 on the DB25 can be supplied with the Mx1053 The DB9F of the cable is connected to the CNC port of the Mx1053 and the DB25M is connected to the DB25F RS232 serial port of a Fanuc CNC machine 3 Jumper Setting P1 P3 P4 and P5 Reroutes the RJ12 Mx2000 HOI Terminal Signal to COM2 as well as COM3 Set jumper setting to D position see diagram below as i Mx1053 RJ12 Jumper Setting for P1 P3 P4 and P5 4 Jumper Setting JP16 24 TR Routes 24 VDC to provide Power to the Mx1053 if a tape reader is being used Set jumper setting to OFF position 5 Jumper Setting JP33 COM3 RJ12 PWR Routes 9 VDC to COM3 for the Mx2000 Terminal 9VDC 350 mA Set jumper setting to OFF position If an Mx2000 Terminal is to be used set jumper setting to ON position Memex Automation Inc 200 3425 Harvester Rd Burlington ON Canada L7N 3N1 Phone 905 635 1540 Fax 905 631 9640 www memex ca Page 3 of 25 ISO9000 DOCs M100728F UNI Pictorial Installation Manual MAI doc Described below are the three p

Download Pdf Manuals

image

Related Search

Related Contents

TDSH ー BA 東芝電球ペンダント取扱説明書 保管用  Axor Citterio 41730XX0 User's Manual  15炎月CT 取扱説明書 - SHIMANO  デジタル顕微鏡 取扱説明書  Elektro-Kettensäge Motosega elettrica Elektrische  STT850 Series HART/DE Option User`s Manual  要求水準書(案)<H15.3.13>[PDF形式:274KB]  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.