Home
Intelligent Plus User's Manual.cdr
Contents
1. adjusts the turbo fan speed to the temperature outside the vehicle Select this function with the menu key and wait for 3 seconds RUTOMATIO MODE E If automatic mode is active a flashing will appear to the left of temperature in the L C display Pressing the system on off switch will cancel Sdll Sea A PERA eau BC 16 68 automatic mode and turn the turbo fan off Note In automatic mode the system water pump and turbo fan is always on lf temperature outside is very low the turbo fan will work at minimum speed 7 9 e C C C C C C E ar re CT ase Due 5 29 28 2 21 1 26 25 1 24 5 23 22 2 X VIESA Temperature This function allows selecting the outside temperature display in degree T THOCGOTIIGE Celsius C or Fahrenheit F Select this EA function with the menu key and wait for 3 seconds ap Press key Q or to select C or F and wait for 3 seconds Note Below 5C 23F or above 70C 158F the display will show The temperature sensor is placed inside the system s roof mounted unit Important If the temperature sensor is not connected the following message will appear on the display GEL JE M VIESA MAINTENANCE The equipment will delay in cooling until the evaporator is totally wet Do not use fuses higher than 15 Amp The equipment will deactivate automatically due to low tens
2. any other incidental punitive or consequential damages The Manufacturer reserves the right to make the final decision on any warranty claim that may be questionable This warranty is not transferable EXCEPT AS PROVIDED HEREIN THIS WARRANTY EXPRESSLY EXCLUDES De i all warranties and conditions whether express implied or statutory including but not limited to warranties and conditions of merchantability for a particular purpose and ii any agreements representations affirmations warranties or conditions whether oral or written made by any agent employee or representative of seller This warranty sets forth the entire responsibility of Manufacturer and Distributor with respect to the Product The buyer s exclusive remedy is repair or replacement as stated herein In no event shall Manufacturer or Distributor s liability exceed the cost of correcting defects as provided herein and any such liabilities will terminate upon expiration ofthe two year warranty period USER S MANUAL VIESA INTELLIGENT PLUS REVISION 003 1 2012 RCR Systems P O Box 1352 1500 Avenue Road Toronto Ontario M5M 0A1 CANADA Ruta 11 Km 814 Guadalupe Norte Prov de Santa Fe S3574XAB ARGENTINA ORDER ON LINE www viesa ca 1 888 438 8444
3. Me VIESA ECOLOGICAL COOLERS INTELLIGENT PLUS User s Manual www viesa ca 1 888 438 8444 M VIESA IMPORTANT Installation requires an experienced mechanic with specific knowledge in the installation of the VIESA Ecological Cooler Installation disassembly repairs and maintenance must be performed by an Authorized Installer Authorized Installer must use proper protective equipment when installing the system Improper installation or use of unauthorized parts can cause malfunctions loss of battery life or other consequences which may result in serious injury Manufacturer or Distributor will not be responsible for injuries or damages resulting from misuse of equipment use contrary to operating instructions or installation by any person other than an Authorized Installer Information contained in this manual is subject to change Manufacturer reserves the right without notice to make changes in equipment design or components as progress in engineering manufacturing or technology may warrant World wide Patents VIGIA is a trademark of Col Ven S A Mx VIESA Function VIESA Intelligent Plus is a roof mounted cab cooler that delivers cool air to the truck s cabin using evaporative cooling and without running the truck s engine O peration Cooling is generated by vaporized cool water delivered by a self contained electrical motor During operation it only consumes water and it makes no use of internal combustion
4. away from children Wrong use may cause fire or burns Do not recharge or heat batteries Dispose dead batteries according to local laws Replace batteries with the same type AAA Batteries may explode if not correctly inserted Immediately dispose of dead batteries Do not throw them into fire LEFT AND RIGHT LIGHT SWITCHES 1 ON DIM 2 ON BRIGHT 3 OFF M VIESA DISPLAY INDICATIONS Permanent Information 1 2V 30 AG 1 0 00 D Baitery voltage O External temperature C or F i 3 Clock 24H 24 hours or 12H AM PM Language Selection Press the button The display will show LAHGUAGE Wait for 3 seconds the word ENGLISH will appear Select language by pressing the Q or key English French FRANCAIS Portuguese Germany Italian TAL PARO Spanish Dutch NEDERLANDS New language is stored after the desired language is selected and no other key is pressed for 3 seconds Example to select Spanish language Press the bottom The epa will show LANGUAGE Wait for 3 seconds the word will appear Pressthe orthe Y key until the display shows Wait for 3 seconds Spanish language is now stored m uy RR et ii Important If the Viesa system is disconnected from the vehicle s battery all set up functions will revert to default X VIESA Please refer to the list below to
5. change LANGUAGE to ENGLISH English French LANGUE Portuguese German Italian Spanish Duch Turbo Fan FOH ON AT By pressing the ON OFF switch O turbo fan and water pump are activated The L C display will show FAN ON and speed F AN ON AS There are 8 fan speeds which can be selected Pag UN do by pressing the QU keys FF OAS By pressing again the ON OFF switch n the system will turn off Water Pump The water pump will be disconnected by pressing the Q key PUMP OFF A PE The water pump will re connect when pressing PUMP OH the key again Note The key Q will connect or disconnect the water pump even if the system is off If the water tank is empty the pump will not operate and a message and sound alarm will result To turn off the alarm and message add water to the tank or press the water OQ pump key Important Alarm and message will disappear approximately 3 minutes after water is added to tank M VIESA If the water pump is disconnected a message and sound alarm will result Alarm and message will disappear as soon as the pump is re connected or the pump on off G switch is pressed DI ihe le Important WATER TANK EMPTY and PUMP DISCONNECT messages and alarm will only appear with the water pump ON Light Control Every time the light switch Q left or right
6. d self power on are active d and e will flash alternatively In 24H mode self power on is cancelled by entering zero values for hours and minutes Hill He Fam aa In 12H mode self power on is cancelled by ale entering a12 00 Note Self power can be programmed even with the system turned off Self Power Off This function allows turning the system off automatically at a predetermined time The following explanation is for 24H mode Select this function with the menu key O and wait for 3 seconds The hour flashes press the AT keys to set the hour Ni Wait for 3 seconds or press the menu key to move to minutes Press the Q keys to set the minutes and wait 3 seconds or press the menu key to finish Note To fast scroll press and hold the up or down key YY M VIESA If self power off is active a flashing a will appear instead of the semi colon in the L C display clock AU SEC ELI Note When alarm clock self power on and self power off are all active a d and e will flash alternatively no i fl In 24H mode self power off is cancelled by Yi entering zero values for hours and minutes In 12H mode self power off is cancelled by entering a12 00 EN Note Self power can be programmed even with the system turned off Automatic Mode This function automatically
7. e VIESA ECOLOGICAL CAB COOLER the e dd by Col Ven S A the Manufacturer and distributed by RCR Systems Limited the Distributor The warranty period is two years from date of original purchase by the buyer During this period if the product is found to be defective in mechanical or electrical materials or workmanship during normal use it will be repaired or replaced at no charge to the buyer The buyer will be required to show date and proof of purchase and to return the Product pre paid to an Authorized Dealer THIS LIMITED WARRANTY DOES NOT COVER AND MANUFACTURER OR DISTRIBUTOR WILL NOT BE RESPONSIBLE FOR THE FOLLOWING Normal wear of parts l Failures or defects due to negligent use misuse neglect abuse use on improper voltage or current use contrary to operating instructions accidents alterations disassembly installation repair or alteration by any person other than an Authorized Dealer fire floods or acts of God Products or accessory equipment not manufactured by the Manufacturer a ermana of Product when used in combination with other products or equipment not manufactured by the anufacturer Payments for labour or service to unauthorized representatives or service agents Manufacturer or Distributor will not be responsible for loss of time inconvenience loss of use of the Product injury to buyer or other persons or damage to vehicle or property caused by the Product or by its failure to work or for
8. e alarm clock is active a flashing d will appear instead of the semi colon in the L C display clock 4 SBc 16408 Important While the alarm clock is active all other alarm sounds are cancelled LCD messages will continue M VIESA Note When the alarm clock is activated both system lights will turn on automatically in the dim position for one minute and then turn off To switch lights off immediately press any key on the control panel or remote control and use the Q key In 24H mode the alarm clock is cancelled by entering zero values for hours and minutes TE Aa In 12H mode the alarm clock is cancelled by entering a12 00 Note The alarm clock cannot be set to 00 00 or a12 00 Self Power On This function allows turning the system on automatically at a predetermined time The following explanation is for 24H mode Select this function with the menu key O and wait for 3 seconds TELE gn The hour flashes press the QU keys to set the hour afl GA Wait for 3 seconds or press the menu key to move to minutes Press the YU keys to set the minutes and wait 3 seconds or press the menu O key to finish Note To fast scroll press and hold the up or down key YY X VIESA 241 Da If self power on is active a flashing e will NAAA appear instead of the semi colon in the L C display clock Note When both alarm clock an
9. engines nor does it use chemical coolants or emit gases into the atmosphere The unit is equipped with a water pump located in an auxiliary tank which takes water to the evaporator A biturbo blower pushes the exterior air to the interior of the truck forcing the air through the evaporator and therefore cooling the warm air The exceeding water backs to the water tank Application Applied to any vehicle withan operating voltage of 12 V M VIESA BOARD INDICATIONS Important before switching on the equipment With parked vehicle Open one of the windows 2 to 3 cms With the vehicle in motion Open one of the windows 2 to 3 cms and close all other air entrances to the cabin so that hot air does not enter from exterior BOARD SYSTEM ON OFF SWITCH Q TURBO FAN SPEED CONTROLS IN MENU SET UP MODE PRESS TO SCROLL FUNCTIONS WATER PUMP ON OFF SWITCH LANGUAGE TIME ALARM CLOCK SELF POWER ON SELF POWER OFF AUTOMATIC MODE TEMPERATURE MENU FUNCTION SET UP L C DISPLAY BATTERY VOLTAGE OUTSIDE TEMPERATURE CLOCK Note time is expressed in 24H mode Keys must be held pressed for 1 second A beep will be heard every time a key is pressed By default language is ENGLISH time is in 24H format and temperature is shown in REMOTE CONTROL Performs all the functions explained before except when the equipment is off Keep the batteries of the remote control
10. ion so as to prevent damages to the battery Use only clean water Foresee replenishment of water taking into account that the equipment consumes between 2 and 5 litres per hour depending on the ambient temperature During short stops leave the equipment on so as to keep the cabin VIESA SCENTED FLUID EVERY 200 HOURS OF USE fresh System must be turned off when exhaust fumes or toxic particles could enter the cab through the system A When performing maintenance of the equipment or if the evaporator unit s cover or the upholstery cover are removed the system MUST NOT BE SWITCHED ON and you must not switch it on with any of these elements removed Keep the tank clean Every 200 hours of use Drain all the water from the tank by removing the drain plug Rinse with clean water thoroughly Pour one bottle of Viesa Scented Cleansing Fluid Fill up the tank with clean water Each 6 months change the package of granulated C alfa Bas crystals Do not use chemical products to clean the control panel Every 2 months or according to working conditions Submerge the evaporator in water with bleach 1 Clean the grids of the air entrances 2 Clean the filter of the collector tray 3 Once a year replace the evaporator 1 Reconnect water returning hose to the filter of the collector tray according to the figure x VIESA LIMITED WARRANTY This limited warranty is provided to the anginal buyer only and covers th
11. is pressed the corresponding light changes according to the following cycle ON dim ON bright OFF FUNCTIONS To set up menu functions press the menu key and scroll to the desired function Wait for 3 seconds on the selected function and the programming mode will start Language see Language Selection before Time Alarm clock Self power on Self power off Automatic mode Temperature Time Setting Select this function with the menu key and wait for 3 seconds The following explanation is for 24H mode SET TIME sau an am The 24H mode flashes press the AQ key if you want the 12H mode instead The hour flashes press the aly keys to set the hour X VIESA Sal an an Wait for 3 seconds or press the menu key to move to minutes Press the keys to set the minutes and wait 3 seconds or press the menu key to finish Note To fast scroll press and hold the up or down key AY Alarm Clock To set the alarm clock select this function with the menu key and wait for 3 seconds The following explanation is for 24H mode ALARM CLOCK The hour flashes press the QU keys to set the hour ct mo Wait for 3 seconds or press the menu key to move to minutes Press the QO keys to set the minutes and wait 3 seconds or press the menu Q key to finish Note To fast scroll press and hold the up or down key QU If th