Home
Service Manual Moffat
Contents
1. EN _ m ral E S Se Cas 4 ff 4 ES Ar NS S Ow as 2 E we SSL COMPRESSOR x RE a COMPLETE REFRIGERATION CYCLE COMPRESSION PHASE While the compressor is working the refrigerating in a gas stage is released into the condenser An expansion valve called capillary which is a small interior diameter tube connected to the condenser outlet limits the refrigerating flow from the condenser this makes the compressor increase the pressure to the condenser El especialista en servicio de linea blanca CONDENSATION PHASE The compressed refrigerating gas in the condenser is warmer than the temperature of the environment this is the reason why the heat of the high pressure gas is transferred to the metal of the condenser which yields it through convection to the surrounding air When loosing the heat the high pressure gas begins to condense the refrigerating liquid flows due to gravity and or the pressure difference to the final end of the condenser and at the time of being forced by the compressed gas contained in the condenser flows into the expansion valve capillary EXPANSION PHASE Due to the pressure is higher in the condenser than in the evaporator the refrigerating expands adiabatically in the capillary until it reaches the evaporator pressure EVAPORATION PHASE The refrigerating liquid at a high pressure and flowing from the capillary at a very high speed gets
2. 12 DEFROST CONTROL 13 DEFROST THERMOSTAT KLIXON 14 SOLID STATE RELATO 15 TERMIC PROTECTOR Ekoso 16 DEFROST RESISTANCE 16 ELECTRIC AND CONTROL SYSTEM DIAGRAM 17 IN pe M 19 AIR FLOW DIAGRAM 21 ELECTRIC DIAGRAM 22 GABINET SYSTEM om Eo ass 23 SUPERIOR HINGE 23 INTERMEDIATE HINGE ooo 23 INFERIOR HINGE 25 FAILURE LOCATION CHART stones mma 26 REPLACEABLE PARTS 28 El especialista en servicio de linea blanca mabe INTRODUCTION For a refrigerating system to work it is necessary to make refrigerating go repeatedly through a closed circuit that is basically compound of four phases Compression Condensation Expansion and Evaporation The refrigerating is circulating all the time when the compressor is working creating a pressure difference within the system LOW SIDE PRESSURE HIGH SIDE PRESSURE EXPANSION lr S VALVE 4 K S e 47 o SV S y qo pt 4 aN 4 a a y 28 Y c P 4 ES y X EVAPORATOR The heat flows from the The heat flows from the 7 CONDENSER room air to the refrigerant refrigerant to the room air ee a p i 4 SS A gt
3. SHAFT CONNECTED TO THE KNOB El especialista en servicio de linea blanca To replace the control of temperature follows these steps gt 1 Retire the bulb control of the cover duct with enough care not damaging the subjection flanges 2 Remove the protective lamp and the bulb to avoid damaging them 3 Unscrew the box control 4 Retires the control knob 5 Releases the control of temperature from the flanges of subjection of the box 6 Places the new control in the original position When the control of temperature is replaced it is very important the assembly and placement of the capillary tube for that it will be left exactly in the same position that the control that was replaced was CONTROL OF DEFROST The defrost control consists on a motor mounted in a plastic box that takes in its interior a revolvable levy and a switch a pole two shots type In the exterior it has 4 numbered terminals The motor is connected in series with the control of temperature and it only works when the contacts of this are closed terminals 1 and 3 to the terminal 2 the circuit is connected in heater series thermostat The terminal 4 is connected the terminal L of the device of outburst of the compressor The purpose of this control is to regulate the frequency and duration of the cycle of defrost The frequency is every 10 hours and its maximum duration of 30 minutes SWITCH CONTACTS GEARING OF THE MOTOR This elemen
4. mabe Service Manual Moffat MTRO9YATWW MTRO9YATSA MTRO9YATCS MTR10YATWW El especialista en servicio de linea blanca mabe INDEX INTRODUCTION 1 COMPRESSION PHASE 1 CONDENSATION PHASE 2 EXPANSION PHASE 2 EVAPORATION PHASE 2 REPAIRS P X 3 SED URITY ee 3 WARNING 3 CARE AND RECOMENDATIONS 3 BEFORE CONSIREDERING THAT A SEVICE HAS BEEN ACCOMPLISHED 3 RECOMENDATIONS TO USERS 4 INSTALLATION scs os se lne o supeo e pep keto 4 SYSTEM CHARACTERISTICS 5 REFRIGERATING UNIT SYSTEM 7 COMPRESSOR 7 AUXILIARY SERPENTINE TUBE 8 CONDENSADOR is 8 CONDENSER TUBE LOOP 8 9 CAPILLARY TUBE 2 9 EVAPORA TORA 9 SUCTION LINE AND HEAT EXCHANGER 10 REFRIGERATING UNIT DIAGRAM 11 ELECTRIC AND CONTROL SYSTEM 12 TEMPERATURE CONTROL
5. BLUE SME TIMER AND COMPRESSOR UI BROWN __ ORANGE BLUE POWER SUPPLY N WHITE CORD HARNESS i TONAS 7 2 lt lt THERMAL PROTECTOR 20 El especialista en servicio de linea blanca mabe FAN The fan is the one in charge of moving the air inside the compartments freezer and cooler the form of making it is attracting the air of the compartments through the surface of the evaporator The cold air is suctioning by the cross and impelled by the diffusion grill toward the freezer another part of the air is impelled toward the cooler through the duct foam The air warms it directs toward the evaporator through return conduits The fan of circulation of air only works while the compressor works During the period of defrost none of both works since the timer opens the circuit that feeds them while it is carried out the unfreezing In these models the fan goes mounted on the baffle resistance that is part of the cover evaporator or Screen that it works like rear support takes a grommets couple or shocks to avoid transmitting vibration For the front a couple of screws are placed to hold it with a metallic front support After the front support the reel is placed end to end with the arrow of the motor and at last the diffusion grill mounted on the screen DEFLECTOR BACK BASE MOTOR FAN DIFFUSER koki GROMMETS GRID 21 El especialista en servicio de linea blanca mabe To replace
6. according to the diagram Verify voltage and indicate the client to modify his installation Replace Replace Replace Verify with an amperemeter and replace Compressor starts but immediately protects Plug false contact Clogged tubing False contact in component connection 4 Excessive power supply in the thermal 5 Excessive gas charge 6 Inadequate Compressor for the unit w N gt Correct plug 2 Replace or unclog the tubing Strengthen the connection o replace components Verify electric Diagram Provide adequate load Replace right compressor The compressor has short cycles Inadequate thermal protector Defective temperature control air flow on the obstructed condenser or dirty condenser Excessive gas charge PTC defective Low Voltage WON DO DO Replace the right one Replace Eliminate obstructions and clean condenser Provide right charge Replace Check voltage and Indicate the client to repair his installation 28 mabe El especialista en servicio de linea blanca 9 Air flow on the obstructed condenser or dirty condenser Restriction in the system Faulty control of temperature Wrong control of temperature or very cold graduation Refrigerator exposed excessive heat to 10 The interior light doesn t turn off
7. away from cutting edges high temperature components nor motion parts Make sure that al the electric ends without insulation connectors heaters etc are properly away form metal parts If the cables screws bases suspenders strips knots or ground connection used to end a line to ground are removed to initiate a service they should be placed back and adjusted properly El especialista en servicio de linea blanca ma be c RECOMENDATIONS TO THE USER The power cord of this appliance has a 3 prong grounding plug which must mates with the wall outlet to minimize the lt L possibility of electric shock Request that a qualified electrician verifies the wall outlet e and the electric circuit to make sure that the outlet where N your device will be connected is properly lined to ground Do not cut or remove the third prong ground of the power supply cord plug under any circumstances When a matching outlet is not available it is the user s obligation and responsibility to replace it for a grounded matching one Do not remove this prong of the plug GROUND It is not recommended the usage of electric extensions if used make sure that they are the same characteristics as the power supply cord of this device Never plug another device to the same outlet due to it may cause voltage variations INSTALLATION Remove the bases package and accessories Select the area to place the refrigerator this must
8. be GODO SECURITY IMPORTANT SECURITY WARNING Service Manuals are intended to be used by persons with a proper experience background on electricity electronics and mechanics Any attempt of repairing a devise without all this knowledge may result on personal injury and property damage The manufacturer and the retailer are not liable for the misunderstanding of its service manuals neither assumes any obligation related to their usage CARE AND RECOMENDATIONS Always unplug the product from the power supply or disconnect it at the household distribution panel by removing the fuse or switching off the circuit breaker before repairing If the usage of power supply is required by specific diagnosis for instance electrical tension etc connect the power supply only for the time required to perform such diagnosis and disconnect it immediately afterwards During such inspection make sure that not any other conducting parts panels etc or your self are exposed to energized metal parts Do not attempt to repair a product if you have any doubt about having the skills to carry it out safely Never disable or alter the right operation of a security device Consult the electric diagram on the back part of the refrigerator BEFORE CONSIDERING THAT A SERVICE WAS FINISHED Make sure that all the electric connections were made correctly and that they are firmly secured Make sure that all power conductors are properly insulated and firmly secured
9. be maintained clean and moisture free so rusting problems are avoided Avoid to place the refrigerator near heat sources such as ranges ovens heaters or to expose it to sunlight It is necessary to leave some space aside and above the refrigerator as well as to lain it on the wall In order to level the refrigerator use the screws inserted in the device The front part must be slightly higher that the back part to ease that the door closes by it self El especialista en servicio de linea blanca md be y CHARACTERISTICS OF THE SYSTEM This manual is focused on the refrigerators produced by Mabe Refrigerator Freezer kind with automatic defrosting called Moffat 2001 All the refrigerators with automatic defrosting have an electric circuit compound of a defrost control a heater and a thermostat A Refrigerator Freezer is such that has one compartment for food and another Freezer one at least both separated with average temperatures of 13 3 C or less in the Freezer Generally the user is able to adjust the temperature to 17 C or less Moffat 2001 refrigerator has a single evaporator that gets defrosted automatically within programmed intervals The evaporator is located in the bottom compartment that is separated from the fresh food compartment by a polyurethane foam wall The airflow over the evaporator and the refrigerating and freezing compartments is provided by a fan with alternating power motor More air
10. de linea blanca mabe SYSTEM CABINET p uu SUPERIOR HINGE The superior hinge is subject with three screws fixed one against metallic The design of this against it allows that their bores always coincide with the bores of the cabinet avoiding this way lack of alignment of the door freezer To retire this hinge the three screws of hexagonal head they should be removed used for their subjection INTERMEDIATE HINGE The intermediate hinge is made of colored steel of the color of the cabinet it is accompanied by a plastic butt with forced closing mounted in the end of the freezer door This butt helps maintain the door freezer closed and to avoid this way introduction of heat to the refrigerator To change this hinge it is necessary to retire the door freezer firstly and later on to remove the two hexagonal screws that hold it to the mullion of the cabinet The third screw should be loosened until the point where it allows retiring the hinge laterally 25 El especialista en servicio de linea blanca mabe Soc FIXING HOLES HINGE BASE INTERMEDIATE HINGE CLOSING STOPPER FORCED 26 El especialista en servicio de linea blanca mabe INFERIOR HINGE The inferior hinge is fastened under the refrigerator on a metallic reinforcement that allows to give rigidity to the cabinet and at the same time it works like hinge pinning To carry out the replacement of this hinge the following steps they s
11. epoxy sealed The connection cables welded to the internal terminals come out through the box TERMINALS _ P f Z 2 IF m Z CONTACTS BIMETALLIC CLIP b BRACKET SENSOR SURFACE When the frost has melted the temperature completely in the evaporator it begins to increase quickly the thermostat detects this change of temperature the bimetallic disk bends and pushes the fastener against the jetty of the switch and the contacts open up avoiding this way the step from the current to the Defrost heater In a contrary way when the temperature in the evaporator is the sufficiently cold the bimetallic disk bends in opposed direction and the jetty of the switch pushes the fastener and it closes the contacts allowing the current flow toward the defrost resistance The thermostat is located to the exit of the evaporator inserted firmly with a clip type band to maintain the contact with the tube evaporator El especialista en servicio de linea blanca mabe RELAY OF SOLID STATE PTC This relay called PTC for their initials in English Positive Temperature Coefficient Relay of Positive Coefficient of Temperature it consists on a tablet of solid state that to ambient temperature it has a low electric resistance from 3 to 25 Ohms The tablet is placed between two electric terminals that are connected to the compressor When voltage is applied to the circuit of the compressor the current flows for the work reel and
12. front frame of the cabinet to the height of the compartment freezer It unites in their initial end with the condenser and in their final end with the dryer This component is not serviceable due to the foam that covers it El especialista en servicio de linea blanca DRYER Its primordial function is to retire the possible humidity contained in the coolant to avoid contamination of the system The humidity is absorbed by a material called silica which characteristic is the one of retaining with great speed the humidity also the solid pollutants are retained by a mesh that it is placed to the exit of the bulb The dryer is located to the exit of the condenser tube loop and the entrance of the capillary tube to replace it you must unsolder these unions MESH MESH Whenever it is carried out load of coolant the dryer will be replaced to avoid contamination in the system CAPILLARY TUBE The capillary one is a tube of very small diameter which main function is the one of to control and to regulate the flow of liquid coolant toward the evaporator The diameter of the capillary one is so small that it originates a reduction of pressure of the coolant liquid that helps to maintain a differential among the lines of high and low pressure necessary in the system during the work cycle The capillary one unites to the exit of the dryer and it is welded by the exterior of the suction line forming this way an interchanger of
13. heat The capillary one ends in the entrance of the evaporator EVAPORATOR The evaporator is the component in which the coolant liquid is transformed to the gassy state when absorbing the heat of the interior of the cabinet taking place with this the coolant effect Inside the evaporator a low pressure exists since the coolant liquid has gone by the capillary one this pressure drop causes that the liquid evaporates to a low temperature All the heat that is absorbed in this phase gets lost in the condensation phase El especialista en servicio de linea blanca The Evaporator is united in its initial end to the capillary tube and in its final end to an accumulator necessary in the system to store the coolant liquid that didn t reach to evaporate in this phase since for the efficient operation of the system should not pass liquid toward the suction tube nor the compressor UNSOLDER THESE TUBES PPER APPENDIX Zi COPPER APPENDIX EPOXY WELDING JJ alle ACCUMULATOR EPOXY WELDING ALUMINUM TUBE The evaporator is manufactured of aluminum tube with thorns or fins that in the exterior to increase its efficiency of absorption of heat When it is required to replace the evaporator it is necessary to do it together with the accumulator since the evaporator is together to the accumulator with epoxy welding not available for the technicians of service unsolder of the copper appendixes indicated in the figure SUCTION
14. in parallel it flows for the PTC and the outburst reel Then the resistance increases instantly and it reduces the current flow through the relay to an intermittent movement this intermittent movement of the current makes that the resistance of the tablet stays high and maintain open to the relay To verify the PTC with an ohmmeter it checks the resistance among the terminals 2 and 3 it will be from 3 to 25 Ohms to ambient temperature If the reading of the resistance is zero the PTC it is in short circuit If the reading of the resistance is infinite or very high the PTC is open TABLET TERMINALS TERMINALS El especialista en servicio de linea blanca THERMAL PROTECTOR The thermal protector is the device used to protect to the compressor against overload it opens up when there is excess of heat or current It has a small heater of integral reel that is connected in series with those reeled of outburst and the compressor start It is connected directly to the terminal common of the compressor To verify the thermal one the resistance between the terminal of the fluke and the terminal of the female peg should be of less than 1 Ohm to ambient temperature If the thermal one is open their resistance will be infinite DEFROST RESISTANCE The defrost resistance or heater it is designed to generate the enough heat to melt the frost formed in the evaporator during the 10 working hours of the compressor that precede
15. initial position El especialista en servicio de linea blanca AUXILIARY SERPENTINE TUBE This component is part of the condenser Their main function is to defrost water that accumulates in each cycle of unfreezing in the drain pan This serpentine receives the discharge of the compressor directly soothe temperature of the tube provides enough heat to carry out the evaporation of the water It is located inside the drain pan separated from her for shocks to avoid noise caused between both by the vibration during the step of coolant To replace it you must unsolder the joints with the discharge of the compressor and with the spare condenser and to remove it of the drain pan CONDENSER Their main function is the one of retiring the heat inside the system toward the atmosphere through its metallic walls since when the pressure in the condenser increases it also increases its temperature when it is higher than the air that surrounds it flows toward the environment When losing the contained heat the gas will change to the liquid state after leaving the condenser In the case that concerns us the condenser comes fastened with screws to the back cabinet it unites in their initial part to the auxiliary serpentine and for the other end to the condenser tube loop To replace it will be unscrewed of the back CONDENSER TUBE LOOP It is an extra part of the condenser that is good to avoid condensation in the mullion and in the
16. into the tube considerably long of the evaporator The evaporator is at a low pressure because of the suction inside the compressor this way the spontaneous pressure decrease causes that the liquid gets vaporized and absorbs heat The heat in the interior of the cabinet is transferred through convection to the evaporator because the evaporator temperature is lower than the airs At the moment of flowing out from the evaporator all the refrigerating liquid has been evaporated so only saturated or slightly overheated vapor returns to the compressor through suction REPAIRS This manual is intended to explain how the main components work and how to replace them in case they are replaceable parts and also some general recommendations to detect certain failures considering that each service requires a particular diagnosis depending on the failure description besides the assumption that the technician has the proper knowledge for diagnosing and repairing the failure This manual must only be used as a guide For the replacement of components of the refrigerating unit or the electric system it is assumed that the technician has disconnected the unit form the power before to initiate any repairs besides he has unsoldered the necessary joints as well as welded them again to finish the service and also that the refrigerating of the unit has been emptied from or loaded to the unit whenever required El especialista en servicio de linea blanca md
17. the motor or the reel fan is not necessary to retire the screen since one can have access removing the diffuser grill To replace the components shown in the figure they will be retired in the suitable order 1 Retire diffuser grill 2 Retire reel fan 3 Retire frontal support removing the screws 4 Retire motor fan with shocks and disconnect cables The diffuser grill has two subjection clips to fasten it to the screen to retire this grill locate these clips at the end of the veins indicated in the figure and with a straight screwdriver press laterally in one of them at the same time pull the grill toward you VEIN COOLER FLOW OPE mabe El especialista en servicio de linea blanca Yep rs DIFFUSER AIR FLOW _ FAN Pa _ EVAPORATOR FOAM DUCT A PITT eo COULDAIR w BRI WARM AIR 2 __ AIR MIXTURE 23 El especialista en servicio de linea blanca mabe ELECTRIC DIAGRAM FOOD m FUSE DEFROST DEFROST TIMER O lt INTERRUPTOR 0 ROJO NARANJA JE AMAR YELI PROTECTOR TERMICO GR a LU E e CTION RIQUE EMARRAGE ERMIQUE 24 El especialista en servicio
18. to the defrost cycle In the terminals of the heater they are connected fusible of 5 Amps to prevent a overheating FUSES HEATER If the defrost resistance ends up failing a blockade will be presented in the evaporator by frost excess or formed ice To verify the operation of the heater the continuity it will be checked of this El especialista en servicio de linea blanca mabe YELLOW ORANGE BLUE MOTOR FAN KLIXON THERMOSTAT RED GREEN GROUND N o PINK WHITE FUSE DEFROST HARNESS _ 2 RESISTANCE RED ORANGE FAN INTERRUPTER POWER PINK SUPPLY CORD BLACK BLACK m BROWN BULB INTERRUPTER GREEN GROUND TEMPERATURE jj CONTROL E GREEN GROUND A BULB n bod C PINK NS WHITE DEFROST TIMER PROTECTION wam lt POWER SUPPLY CORD TO CABINET HARNESS ORANGE 7 CONNECTION Bon Sf SEE NEXT PAGE El especialista en servicio de linea blanca mabe CABINET HARNESS BLUE KLIXON YELLOW TESTS IN SILVERY ORANGE FAN INTERRUPTER BLACK BULB INTERRUPTER WHITE BULB BLACK TEMP CONTROL WHITE RESISTANCE AND FAN BROWN TEMP CONTROL BROWN TIMER 3 BLACK NEUTRAL BLACK EINE BLACK TIMER 4 apne i N ORANGE TIMER 1
19. 11 Large amount of foods 12 Motor fan does not work PROBLEM CAUSE SOLUTION The refrigerator does 1 Deficiency of coolant 1 Verify if there is a leak and not shut off make the right load 2 Inadequate compressor for 2 Replace the unit 3 The doors dont close 3 Adjust doors or replace them if properly necessary 4 Evaporator blocked 4 Defrost and look up the flaw of 9 10 Verify interrupter y correct 11 Inform the client 12 Verify the interrupter activates Eliminate obstructions y clean Restart the system and replace Replace Replace or change to normal the blockade condenser filter position Inform the client and change the place the fan or replace the motor Refrigerator does not cool 1 2 3 Temperature control not calibrated Compressor damaged Capacity of compressor inferior than required Gas leak in the system 5 The motor fan does not work 6 Reels in wrong position 7 Excessive frost in the evaporator 8 Air flow on the obstructed condenser or dirty condenser 9 The doors dont close properly 10 Temperature control bulb placed incorrectly 11 Filter or capillary blocked 1 2 3 8 9 10 the right position 11 Restart the system and replace Repair the leak and charge Verify the interrupter activates Place the reels correctly Verify defrost system and correct Eliminate obstructions
20. Each 10 Compressor Work hrs 30 min 2 C 13 99C 15 6 3 9 280W 120V 58 Ohms 90 Ohms 5 a 21 C 7 5W 2500 rpm Contra las manecillas del reloj 120V CA a 60Hz 0 12 18 C Reciprocating 8 9 127V 60Hz R 134a 128 gr Polyester Emkarate RL15HBE 320 ml PTC 8EA903 901 4TM408RHBYY 53 CBZN122L7G 615 El especialista en servicio de linea blanca mabe SYSTEM COOLANT UNIT COMPRESSOR It takes charge of pumping the coolant gas to the system which receives it from the evaporator that is to low pressure and it gives it to the condenser causing a high pressure in the coolant that increases its temperature in its turn The compressor is the heart of all refrigeration system LIFT THE CLIP BY USING A SCREW DRIVER SHOCK ABSORBER SOLID AXLE E AXLE 9 SCREW In these models the compressor rests on four shocks guided by a solid axle screwed under the support compressor the subjection provides it a steel clip that hooks to the axle in the superior part To replace the compressor once the refrigerator is disconnected of the electric current and the necessary tubes unsoldered follow these steps 1 Pull the subjection clip by lifting the hinge of the clip with a straight screwdriver 2 Remove the compressor damaged together with the shocks 3 Change the shocks to the new compressor and place it in the original position on the axles 4 Insert the subjection clips in their
21. LINE AND HEAT EXCHANGER The suction tube is the component of the system for which the coolant one circulates in gassy state of the evaporator toward the compressor completing this way the refrigeration cycle The interchanger of heat is formed by the assembly of the suction tube with the capillary soldered to it for the external wall its function is the one of transferring heat of the hot liquid that is inside the capillary one toward the contained cold vapor in the suction tube improving the efficiency of the system when being increased the heat in the suction tube it increases the flow that enters to the compressor El especialista en servicio de linea blanca mabe REFRIGERANT UNIT SUCTION LINE EVAPORATOR CONDENSER TUBE LOOP SERPENTINE TUBE AUXILIARY HEAT EXCHANGER CONDEN
22. Resistance 162D6022P006 Defrost Timer 238C1015P002 Defrost Thermostat 200D3568P003 Temperature control 221C5100P002 Dryer These numbers of the spare parts can change with the time they are only like reference to see the total of spare parts and their last update you must refer to the catalog of spare parts and the system of visualization of Serviplus 30
23. SER COMPRESSOR CAPILLIARY 13 El especialista en servicio de linea blanca ELECTRIC AND CONTROL SYSTEM CONTROL OF TEMPERATURE This element controls the temperature of the interior of the apparatus automatically maintaining it inside the preset limits The electromechanical control is able to control the temperature by a bulb sensitive hole capillary and full with coolant which contracts or expands according to the temperature that is measuring When contracting or expanding the coolant one it makes a bellows that is inside the control to work and in turn this bellows disconnects or it connects respectively by means of some contacts a circuit that sends current to the compressor When in the control knob a certain position is indicated the refrigerator begins to work and when the temperature of the evaporator reaches a certain value the coolant one in the control has contracted enough to open the circuit and to stop the compressor When stopping the compressor it stops cooling and the evaporator begins to warm until a certain value of temperature that makes that the gas expand and connect the compressor again Those temperatures which the control stop or pulls up the compressor they call themselves respectively court temperature and outburst temperature and they are those that should be revised with a thermometer to see if the control is well gauged or it is not COULD AIR CAPILLARY BELLOWS CONTACTS
24. and Calibrate control Replace Replace for an adequate the fan or replace the motor clean condenser Adjust the doors or replace them if necessary filter 29 mabe El especialista en servicio de linea blanca Tes PROBLEM CAUSE SOLUTION The refrigerator does not cool in the fresh food compartment but it freezes in excess in The motor fan does not work 1 1 2 Reels in wrong position 3 Air duct blocked 4 Defrost Timer does not work 5 6 Place them in the right position Remove obstructions Verify the interrupter activates the fan or replace the motor 2 3 the freezer 5 Defrost Resistance opened 4 Replace compartment Defrost thermostat opened 5 Replace 6 Replace Noise 1 Loose fixations 1 Locate and adjust fixation 2 Reel fan produces vibration 2 Replace reel 3 Fan cushion worn 3 Replace motor fan 4 Compressor Installed with 4 Replace right shocks different shocks 5 Contact between tubing 5 Adjust tubes so that they are not 6 Compressor with internal in contact among them noise 6 Replace 7 Compressor works with high 7 Place external muffle pressure SERVICEABLE PARTS PART No Description 20601112199 Compressor CBZN122L7G 00000206010 Thermal Protector 4TM408RHBY 53 00000206007 PTC 8EA903 200D2940P002 Motor fan 186D2838G001 Evaporator 221C7058P001 Defrost
25. flows in the freezer than in the refrigerator to provide optimal temperature in both compartments Three different capacities of this refrigerator are manufactured 8 9 and 10 cubic feet designed to operate with a voltage range from 103V to 127V at an operation frequency of 60hz The temperatures in the food compartment must be from 1 C to 7 C in a mid position and in the freezer from 13 C or less depending on the environmental conditions and the food load mabe El especialista en servicio de linea blanca o 0O00 SYSTEM CHARACTERISTICS TEMPERATURE CONTROL tarting temperature Cut Temperature Refrigerant type Defrost time Cycle og Sm 212 dE ge ai 3 m 4 o C dE m a o Q o 2 2 O o 2 3 D z a c D koj U m n A O 0 E m gt m A otency ower RPM s Rotation Voltage Amperage ity cubic feb ODO UU O lo gt o 5 5 ko A o o 9 5 iS o Tlo lao A 5 5 m Sla 9 o o O 5 lo o x 39 O lo O o 7 D alo a KE fficiency BTU hr A 5 ype of Refrigerant m SIZ SIE 2 lo 0 Q 4 Oil type Oil load tart TC No hermal protector No 2 gt 2 D z 2 mt a Environmental with thermal mass 1 ee ee 10 8 16 9 R 1349
26. hould be carried out once you have removed the cooler door INFERIOR HINGE FIXING HOLES 1 Retire the leveling screw 2 Using a 5 16 wrench or Phillips head screwdriver remove the three subjection screws and remove the old hinge 3 Place the new hinge using the bores indicated in the figure making sure that the three screws are tightened 4 Place the leveling screw again 5 Level the refrigerator using both leveling screws and set the apparatus on to make sure that vibration caused by this substitution doesn t exist LEVELING SCREW HOLE 27 mabe TROUBLESHOOTING CHART El especialista en servicio de linea blanca S000 not work PROBLEM CAUSE WHAT TO DO Compressor does 1 Not enough tension the 1 Verify Voltage in the plug operate plug it doesn t emit any 2 Power plug pinched 2 Replace noise 3 Faulty thermal protector 3 Replace 4 Inadequate connection 4 Verify in the diagram 5 Compressor coil opened 5 Check continuity of the coil and replace 6 Temperature Control does 6 Replace start it protects Low or wrong tension Compressor short circuit PTC defective wrong Thermal protector wrong Compressor motor forced 7 Control temperature knob 7 Move knob position position 0 8 Defrost control stuck in 8 Replace defrost Compressor does not 1 Inadequate connection 1 Check connection
27. t is located in the rear part of the refrigerator protected with a metallic box screwed to the bottom back cabinet El especialista en servicio de linea blanca After each 10 compressor working hours the levy has rotated until a point where a couple of contacts of the switch opens up interrupting the electric power feeding to the compressor and it closes the couple that feeds to the circuit thermostat heater The defrost cycle begins when the levy has rotated until the position where the jetty of the contact corresponding to the terminal 4 stops to make contact with the lobe of the levy and he she falls in a notch this opens the first couple of contacts terminals 3 and 4 and the second couple closes terminals 3 and 2 When continuing its turn the levy will reach a point where the jetty with double contact of the terminal 3 will also fall in the notch this opens the second couple of contacts terminals 2 and 3 and he she closes the first one terminals 3 and 4 with that which finishes the defrost cycle THERMOSTAT OF DEFROST KLIXON The defrost thermostat or Klixon are a sensor device of temperature connected in series with the timer and the defrost resistance it detects the increase of temperature of the evaporator during a defrost cycle and it disconnects the resistance once he she comes undone the whole frost It consists on a switch of simple pole a bimetallic disk and a push fastener encapsulated in a metal box and plastic
Download Pdf Manuals