Operating instructions AS-i Ethernet/IP gateway

image

Contents

1. i a gt Ensure a low resistance connection of the data decoupling terminal FE to the ground of the installation The gateway and both AS i lines are supplied via one power supply PELV 21 5 V 31 6 V AS i or AUX The AS i lines have a thermal short circuit protection 4A Several gateways can be supplied by one powerful power supply 5 2 Wiring Terminal X1 Combicon Terminal X2 Combicon Pin Description or AUX jumper Terminal X3 RJ 45 Configuration interface Terminal X6 RJ45 Ethernet IP interface 2 Terminal X7 RJ45 Ethernet IP interface 1 6 Operating and display elements 6 1 Operating elements OG OD Device LEDs H1 green yellow red Softkeys Navigation buttons Combicon connector X1 Combicon connector X2 or AUX jumper Front flap Slot for SD card Configuration interface X3 RJ45 Ethernet IP interface 1 X7 RJ45 10 Device LED H3 H5 11 Ethernet IP interface 2 X6 RJ45 12 Device LED H2 H4 O CON DM OF WN 6 2 LED indicators 6 2 1 Device LED H1 A diagnostic LED on the AS i Ethernet IP gateway informs you of the state of the device and the connected systems The green LED is lit gt Device has been started gt There is no warning message gt There is no error message Yellow LED flashes slowly 0 5 Hz gt There is a warning message gt There is no error message Red LED flashes quickly 2 Hz 6 2 2 Device LE
2. It visualises sensor actuator data on the integrated WEB server e It allows device configuration via the WEB server 3 1 Configuration interface X3 e 10 Mbps and 100 Mbps e TCP IP Transport Control Protocol Internet Protocol UDP User Datagram Protocol IT functionality HTTP server e RJ45 twisted pair 3 2 Fieldbus interface X6 and X7 Ethernet IP e 10 Mbps and 100 Mbps 3 3 Electrical supply e the unit can be supplied either from 24 V AUX or from AS i e AS i power 24 V compatible 4 Installation gt Fix the AS i Ethernet IP gateway onto a 35 mm raised rail The protection rating of the unit is IP 20 therefore it should be mounted in a protected location e g control cabinet Ensure a condensation free environment Avoid excessive dust vibration and shock The air circulation through the vents must not be impeded Avoid installation in direct vicinity of frequency inverters or other interfering sources 5 Electrical connection The unit must be connected by a qualified electrician gt Disconnect power before connecting the device gt Observe the national and international regulations for the installation of electrical equipment gt Connect the device as indicated on the terminals gt Ensure an electrical connection between the AS i Ethernet IP gateway terminal FE and the ground of the installation gt Only insert or remove the AUX jumper when the device is disconnected Otherwise a device fa
3. CE 7390927 00 04 2014 ifm electronic Operating instructions ecomoakaoo AS i Ethernet IP gateway AC1421 AC1422 Contents 1 Preliminary note arrrsrrrnrons vors vnr vnr rn rn nrrsnrrnnrrsnnrnnvrnn vann vers nrnn vnr nnns vnr vnr nen nn 4 1 1 Notes on this COCUMENL cccccccccccccssesccceccceeesececeucuaesececuucanssseeeeutaanenssess 4 1 2 Symbols used rrrrrnrrnrrrsrrrnrorvrervrrsvrrsvrrnrernrrsvrrnvrrnrennrennresversrnsnrsrnrssvrssvessnennn 4 2 Safety instructions oo ce ccecsecssessecsescseesescseseecsesseecseseeceeseeeceesaesaescaeseuseaeeeeeees 4 2 1 General r rrsrrrrmmrrmmmmnmmmssserereersrrrrsrsnnsssesssssssseeene 4 2 2 Installation and CONNECTION cccccccccccceececcccccceeescccccceuuecececcueeaeeseeeuetaneeseess 4 2 3 Tampering with the device n srrasrrrnrrrnrersrrrn vors rrrsvrrsvrrnvrrsnresnrsrnrsrnrernvernnennn D 3 Functions and features cccccccccccccceessseccccececceeeeseeeeceuueceueesseeeeeueueeanenessuesennnes 5 3 1 Configuration interface X3 rrrsrrrnrrenvrrvrrrvrrrvernverrrrvrrsversvernrenvessversveesveenvesnnn 5 3 2 Fieldbus interface X6 and XT ccccccccssesecccccccecccceeccecececeuceuaesseseceeeuueausaesseseess 5 3 3 Electrical SUPPLY ccccccscssssescsrscsrscsrscsescsrecsrecseecsseceresseesseeseatseateanseateeatees 5 PSCC ee i re en 6 5 Electrical CONNECTION cccccccccceeecccccccssecccccueccececcueceeececauseeeeueueseeeusuaeseeeusa
4. Ds H2 and H4 LED status Yellow LED flashes Receipt of data 6 2 3 Device LEDs H3 and H5 LED status The green LED is lit Physical connection ok 7 Operation 7 1 Settings EN During operation the display is switched off after 10 minutes without operati on gt Activate the display by pressing any desired button 0 7 1 1 Language selection gt Change the user language of the device by pressing the button and the A button or Y button simultaneously OnO ay BE 7 2 Navigation 7 2 1 Navigation elements Oo 1 User level 2 Focus 11 CO N 3 71 amp amp Operating area Softkey labelling Navigation compass Navigation status bar Main navigation bar Info bar 7 2 2 Pictograms and main navigation 4 pr A 12 Quick setup Summary of the menu points required for a basic configura tion Project all Projection adaptation for AS i master 1 and AS i master 2 only AC1422 e Operating mode Selection of the operating modes for AS i master 1 AS i master 2 only AC1422 System gateway manual e Fieldbus Display modify the parameters of the Ethernet IP interface P address subnet mask gateway address e Configuration interface Display modify the parameters of the Ethernet configuration interface DHCP IP address Subnet mask Gateway address e Addressing 1 Slave overview AS i line 1 with the option to change AS i address
5. aeneeeens 6 5 1 Device supply cccececssecssesesrecssecssescssecsseeceesesseeeescssessaesentsessesateessesateentes 6 0 1 1 Device supply via AUX AS i supply via AS i power supply 6 6 5 1 2 Device and AS i supply via AS i power supply sesser r 5 1 3 Device and AS i supply via one common power supply rsvrrrvrrnvrnrn if SJ VG ME 8 6 Operating and display elements rrrsrronrrrvrrnrorvrrnrrrvrrsvervrrrrernresnrrnrrsvernrerseenen 9 6 1 Operating elements rorvrrrvrrnrrnnrrrvrrrvrnsvrrnvrnnvrrnrrsvrrsvrrnrernresnrssvrssversvennvennnn 9 6 2 LED indicators SE 10 6 2 1 Device LED Hl rannnnrrrorovrvvvvvrvrrrnnnnnnnssssssssrsevsrrrrrssnnsssesssssseeeerrrrrrsnnn 10 6 2 2 Device LEDs H2 and H4 10 6 2 3 Device LEDs H3 and HB 10 TN 10 Ph SUS means 10 7 1 1 Language selection nrrsrrrnvrnsvrrnnrrnnvrrnnrersvrrnnrennrersvrssnvrnsvessvrsnnveen nen 11 1 2 Navigation s oer eeerernrvneneemnvrnvenenrenrveerrrerrrerrrerrrrrrrrervrrrrrerrnnn 11 7 2 1 Navigation elements rrwrnrrrsvrrrnrrnnvrrnnrersvrrsvrernrrrsvrssnrsenversvrensveen nen 11 7 2 2 Pictograms and main NAVIGATION ssrrsvrrrnvrrsvrrrnrrrsvrrrnvennvrrsvrernrres nen 12 8 Diagnosis rrrrrnrrrvrrsvrrsvrrnvernrrsvrrsvrrnrernresnresversrernrernresnrrsvernresnresnrssrrrsrernresnnennen 13 9 Technical data esesvrnrrrrsnrnnnnnnnnnsrerssrrnnnnnnssssrsrsrrnnnnsnnsssrerrrrnnnssesssrernrrnnunssnssseee 13 2 9 1 Data S
6. es e Addressing 2 Slave overview AS i line 2 with the option to change AS i addresses AS i 1 e AS i master settings e AS i diagnosis AS i slaves AS i 2 AS i master settings e AS i diagnosis AS i slaves i System Information e Settings e Diagnosis interfaces Settings and information of the configuration interface Settings and information of the Ethernet IP interface a OSC Online Support Center e Display of plain text messages with time stamp information Further details see programming manual chapter 9 2 8 Diagnosis Any warning or error message is indicated in the display of the device The pictogram of the function unit concerned is superposed by a warning or error symbol If for one function unit a warning and an error message exist at the same time only the error symbol is displayed i Warning message Error message All messages are displayed in plain text and in the Online Support Center OSC 9 Technical data 9 1 Data sheets E Data sheets can be found at www ifm com Data sheet search gt AC1421 AC1422 19 9 2 Programming manual EN The programming manual can be found at www ifm com Data sheet search AC1421 AC1422 Operating instructions 10 Maintenance repair and disposal gt Replace the buffer battery of the real time clock as required type CR2032 gt Dispose of the device in accordance with the national environmental regulat
7. heets rrrsssrrrrrrrrrrrrnsnnnssrsrrrrrrrrnnsensssrrrrrrrnnsssesssererrrrnnsssessssrerrrsnnnsenn 13 9 2 Programming manual cccscscsscessessrssrsseesseesssesersseesseesseesreseesseeserens 14 10 Maintenance repair and disposal mmrnrrvrrrsverrvrrrrvrrrrvrrerverrsrerssrersvreenvrernnnn 14 11 Approvals standards ssrenvvrnvvrsvornrorsversversversversvresvevsversvresvrervresvreesrersrernreens 14 12 Scale drawing ccccceccscsssccseccseecseessesseecsesceeseeseeeceescnescaeseeeseeseeeseaeseaeseseeaseeas 14 1 Preliminary note 1 1 Notes on this document This document applies to devices of the type AS i Ethernet IP gateway art no AC1421 AC1422 It is part of the device and contains information about the correct handling of the product This document is intended for qualified electricians These specialists are people who are qualified by their training and their experience to recognise and to avoid possible hazards that may be caused during operation of the device gt Read this document before using the device Keep this document during the service life of the device 1 2 Symbols used gt instructions gt Reaction result Designation of pushbuttons buttons or indications Cross reference Important note Non compliance can result in malfunction or interference EN Information Supplementary note 2 Safety instructions 2 1 General gt Observe these operating instructio
8. ilure may occur 5 1 Device supply EN To operate an AS i system an AS i power supply e g AC1236 or the data decoupling module AC 1250 not supplied with a DC power supply is required gt Supply the device with one of the following versions 5 1 1 Device supply via AUX AS i supply via AS i power supply gt Supply the device with a voltage of 24 V DC 18 32 V PELV e g from the 24 V DN3011 power supply of ifm electronic The connection is made to the terminals X2 gt Pull out the AUX jumper gt To supply the AS i lines connect the terminals X1 to one or two AS i power supplies AC 1421 one AS i master AC1422 two AS i masters gt Ensure a low resistance connection of the symmetry point of the device terminal X1 5 FE to the ground of the installation 5 1 2 Device and AS i supply via AS i power supply gt To supply the AS i lines connect the terminals X1 to one or two AS i power supplies AC 1421 one AS i master AC1422 two AS i masters gt Ensure a low resistance connection of the symmetry point of the device terminal X1 5 FE to the ground of the installation EN The AUX jumper is plugged onto the connector X2 factory setting the device is supplied via AS i line 1 X1 3 and X1 4 UK 9 1 3 Device and AS i supply via one common power supply gt Plug the data decoupling module AC1250 not supplied into the terminals X1 and X2 to supply the device and the connected AS i lines AC142x AC1250
9. ions 11 Approvals standards EN The EC declaration of conformity and approvals can be found at www ifm com Data sheet search AC1421 AC1422 Approvals 12 Scale drawing 14
10. ns gt Adhere to the warning notes on the product Non observance of the instructions operation which is not in accordance with use as prescribed below wrong installation or incorrect handling can affect the safety of operators and machinery 2 2 Installation and connection The device must only be installed connected and put into operation by a qualified electrician as the safe function of the device and machinery is only guaranteed when installation is correctly carried out The installation and connection must comply with the applicable national and international standards Responsibility lies with the person installing the device 4 This is a class product The unit may cause radio interference in domestic areas In this case it can be necessary for the user to take appropriate measures 2 3 Tampering with the device Tampering with the device is not allowed and will lead to an exclusion of liability and warranty Tampering with the device can affect the safety of operators and machinery gt Do not open the device Do not insert any objects into the device UK gt Prevent metal foreign bodies from penetrating 3 Functions and features The AS i Ethernet IP gateway includes one AC1421 or two AC1422 AS i masters one WEB server and an Ethernet IP interface with 2 port switch e It controls the exchange of data to the sensor actuator level e It communicates with the superior control level via Ethernet IP e