Betriebsanleitung Operating instructions Mode d'emploi
Contents
1. The properly bared conductors of cables shall be connected with due regard to the respective regulations To maintain the explosion protection conductors shall be connected with special care The insulation shall reach up to the terminal The conductor itself shall not be damaged The minimum and maximum conductor cross sections that can be connected shall be observed see section 1 6 technical data All screws and or nuts of connection terminals including those not in use shall be tightened down securely Excessive tightening may affect or damage the connection The terminals are designed for the direct connection of conductors with copper wires If multi or fine wire connecting cables are used the wire ends shall be handled according to the applicable national and international regulations e g use of multicore cable ends The position of the terminals can be found in the wiring diagram of the switch insert on page 8 technical data To ensure a correct closing of the manual motor starter switching at the switch shaft of the switch insert when the apparatus is open is not permitted If to facilitate the feeding of conductors into the enclosure the switch insert is snapped out of the rail on the enclosure base by releasing the catches top or bottom on insert it shall be snapped back into position in the enclosure base before the electrical connection The end clamps on the DIN rail are used for fi
2. vu sur le lieu d installation log puissance de coupure du court circuit mesur gt 1 6 Classe de temperature et section de transversale du conducteur Plage de r glage Classe de temperature Section transversale min du conducteur Entr e Sortie 0 10A 0 75 mm 0 75 mm 1 60A 1 00 mm 1 00 mm 2 50A E 1 00 mm 1 50 mm2 4 00 A E 1 50 mm2 1 50 mm2 9 00 A ee 2 50 mm 2 50 mm 12 50 A een 2 50 mm 2 50 mm 20 00 A 4 00 mm 4 00 mm ee COOPER Crouse Hinds 1 7 Plage de r glage courant Courant de d clenchement Disjoncteurs moteur jusqu 25A GHG 635 Courant et temps de d clenchement 3 fois 4 fois G00 Al 135 00 12 50 Al 18750A T6 00A 24000 20 00 Af 300 00 25 00 Al 37500A 2 Consignes de s curit L e disjoncteur moteur ne convient pas l emploi dans la zone 0 et zone 20 Le groupe d explosion et la lasse de temp rature marqu s sur les appareils devront tre respect s Les exigences des EN 61241 0 et 1 en ce qui concerne des dep ts de poussiere d mesur s et une temp rature doivent tre consid r es par l utilisateur Il n est pas permis de transformer ou de modifier les disjoncteurs moteurs Seuls des appareils intacts et en parfait tat de marche devront tre employ s pour la fonction qui leur est d volue Seules des pi ces de rechange homolo gu es d origine COOPER Crouse Hinds devront tre utilis es comme remplacement et pour des r paratio
3. 6 4 Plaques brides Si les plaques brides doivent tre d mont es pour percage d entr es de c ble par exemple il faudra veiller lors du montage au maintien de l indice de protection en replacant correctement la plaque ainsi que les brides de serrage Des conducteurs PE amen s de l ext rieur doivent tre connect s la borne PE pr vue cet effet sur la bride Attention les brides m talliques les plaques de fond m talliques et les presse toupe m talliques doivent tre reli s au m me potentiel pour le moment pas encore certifi Cat gorie IID 6 5 Fermeture du dispositif Tout corps tranger doit tre te du dispositif La vis de r glage du courant nominal du socle s ajuste en fonction du courant nominal du moteur Le commutateur du couvercle du disjoncteur moteur doit tre dans la m me position que lors de l ouverture de l enveloppe Lors de la fermeture du couvercle on s assurera que l axe est introduit correctement dans l ouverture pr vue Afin de garantir l indice de protection minimum requis on s assurera que les vis du couvercle sont bien serr es Un serrage excessif des vis peut endommager l appareil e COOPER Crouse Hinds Disjoncteurs moteur jusqu 25A GHG 635 6 6 Mise en service Avant la mise en service de l appareil les v rifications sp cifi es dans les r glements nationaux individuels devront tre ex cut es De plus il faudr
4. 635 Contents Contents 2 Dimensional drawings 8 1 Technical data 8 1 1 Manual motor starters 8 1 2 Auxiliary contact 60 1 3 Undervoltage trip 8 1 4 Max rating current of short circuit back up fuse for max 50 KA sisissssssssessisssszss 9 1 5 Max rating current of short circuit back up fuse for max 100 KA 9 1 6 Temperature class and conductor cross section 9 1 7 Tripping current and time 10 2 Safety instructions 10 3 Conformity with standards 10 4 Field of application 10 5 Application Properties 10 6 Installation son Ul 6 1 le ie ul EE 11 6 2 Opening apparatus Electrical connection 11 6 3 Cable entry KLE blanking plug eee 6 4 Flanges and metal plates 6 5 Closing apparatus 12 6 6 Putting into operation 12 7 Maintenance Servicing 12 8 Repairs Modifications 12 9 Disposal Recycling 12 10 Declaration of conformity 18 Disjoncteurs moteur jusqu 25A GHG 635 pour atmospheres explosibles Contenu Contenu Plans cot s 1 Caract ristiques techniques 1 1 Disjoncteurs moteur 1 2 Contact auxiliaire 1 3 D clencheur sur baisse de t
5. Other temperatures possible for special versions Perm storage temperature in original packing Degree of protection acc to EN IEC 60529 Insulation class acc to EN IEC 61140 Cable entries 0 1A 6 3A 6 3A 25 0A with auxiliary contact undervoltage release Supply terminals Test torques Cap nut of the cable entry M 25 Cap nut of the cable entry M 32 Cover screws Terminals main contacts Terminals auxiliary contacts Terminals under voltage contacts Weight Standard design with auxiliary contact undervoltage release 1 2 Auxiliary contact Rated voltage Rated current AC 15 switching capacity DC 13 switching capacity Perm short circuit back up fuse Terminals 1 3 Undervoltage release Rated voltage Drop value Starting value Short circuit back up fuse Terminals Dimensions in mm X fixing dimensions 140 Il 2 G Ex ed II C T6 T5 amp Il 2 D Ex tD A21 IP66 80 C PTB 99 ATEX 1162 690 V 50 60 Hz 440 V DC upto 25A see point 1 4 and 1 5 page 4 690 V 25A Til see diagram 1 page 3 also point 1 7 page 5 20 C up to 40 C standard version 50 C to 80 C IP 66 standard version I device fulfil this requirement Il with metal flange standard version 2 x M25 for cable 2 x M82 for cable 1 x M25 in addition 2 x 0 75 4 0 mm or 8 17 mm 12 21 mm 1 x 10 mm 3 5 Nm 5 0 Nm 2 5 Nm 3 5 Nm 2 5 Nm 2 5 Nm approx 2 45 kg appro
6. f r Motorschutzschalter Ger tehalter f r Wand und Gitterrinnen befestigung Gr e 3 A Steckbefestigungspunkte f r Motorschutzschalter Motorschutzschalter bis 25A Angaben aus Punkt 3 und 4 sind bei der Verwendung zu ber cksichtigen Andere als die beschriebenen Anwendun gen sind ohne schriftliche Erkl rung der Fa COOPER Crouse Hinds nicht zul ssig Beim Betrieb sind die in der Betriebsanlei tung unter Punkt 7 genannten Anweisun gen zu beachten Die Verantwortung hinsichtlich bestim mungsgem er Verwendung dieser Motorschutzschalter unter Bezugnahme der in dieser Anleitung vorhandenen Rahmenbedingungen siehe technische Daten liegt allein beim Betreiber 6 Installation F r das Errichten Betreiben sind die relevanten nationalen Vorschriften z B Betri Si V Ger tesicherheitsgesetz in Deutschland sowie die allgemein anerkann ten Regeln der Technik ma gebend Unsachgem e Installation und Betrieb der Motorschutzschalter kann zum Verlust der Garantie f hren 6 1 Montage Die Montage der Motorschutzschalter kann ohne ffnen des Geh uses erfolgen Die Schalter d rfen bei der Direktmontage an der Wand nur an den vorgesehenen Befestigungspunkten eben aufliegen Die gew hlte Schraube muss der Befestigungs ffnung angepasst sein siehe MaBbild und sie darf die ffnung nicht besch digen z B Verwendung einer Unterlegscheibe Das Ger t ist mit mindestens 2 Schrauben diagonal
7. von COOPER Crouse Hinds oder einer qualifizierten Elektro fachkraft in bereinstimmung mit national geltenden Regeln durchgef hrt werden Vor Inbetriebnahme m ssen die Motor schutzschalter entsprechend der im Ab schnitt 6 genannten Anweisung gepr ft werden COOPER Crouse Hinds Alle Fremdk rper m ssen vor der ersten Inbetriebnahme aus den Ger ten entfernt werden Achtung Anschlussquerschnitte des Motorschutz schalters in Tabelle 1 6 Seite 4 beachten Beachten Sie die nationalen Sicherheits und Unfallverh tungsvorschriften und die nachfolgenden Sicherheitshinweise in dieser Betriebsanleitung die wie dieser Text in Kursivschrift gefasst sind 3 Normenkonformit t Das Betriebsmittel ist gem DIN EN ISO 9001 entwickelt gefertigt und gepr ft worden Es entspricht den in der Konformit tser kl rung aufgef hrten Normen 94 9 EG Ger te und Schutzsysteme zur bestimmungsgem en Verwendung in explosionsgef hrdeten Bereichen Weitere Anforderungen wie die EG Richtlinie Elektromagnetische Vertr glichkeit 2004 108 EG werden von den Steuerger ten erf llt 4 Verwendungsbereich Die Motorschutzschalter sind zum Einsatz in explosionsgef hrdeten Bereichen der Zonen 1 und 2 sowie der Zonen 21 und 22 gem IEC 60079 10 geeignet Die eingesetzten Geh usematerialien ein schlie lich der auBenliegenden Metallteile bestehen aus hochwertigen Werkstoffen die einen anwendungsgerechten Korr
8. 1 Zertifizierungsstelle Physikalisch Technische Bundesanstalt 0102 Notified Body of the certification Bundesallee 100 Organes Notifi et Comp tent D 38116 Braunschweig Konformit tsbewertungsstelle Physikalisch Technische Bundesanstalt 0102 Notified Body to quality evaluation Bundesallee 100 Organes d attestation de conformit D 38116 Braunschweig F r den Sicheren Betrieb des Betriebsmittels sind die Angaben der zugeh rigen Betriebsanleitung zu beachten For the safe use of this apparatus the informations given in the accompanying operating instructions must be followed Afin d assurer le bon fonctionnement de nos appareils pri re de respecter les directives du mode d emploi correspondent ceux ci CEAG e COOPER Crouse Hinds ei COOPER Crouse Hinds Cooper Crouse Hinds GmbH CZ Tento n vod k pou it si m Zete vy dat ve sv m mate sk m jazyce u p slu n ho zastoupen spole nosti Cooper Crouse Hinds CEAG ve va zemi DK Montagevejledningen kan overs ttes til andre EU sprog og rekvireres hos Deres Cooper Crouse Hinds CEAG leverand r E En caso necesario podr solicitar de su representante Cooper Crouse Hinds CEAG estas instrucciones de servicio en otro idioma de la Union Europea EST Seda kasutusjuhendit oma riigikeeles v ite k sida oma riigis asuvast asjaomasest Cooper Crouse Hindsi CEAG esindusest FIN Tarvittaessa t m n k ytt ohjeen k nn s on saatavissa toise
9. Aufrechterhaltung der Mindestschutzart auf den korrekten Sitz der Flanschplatte und den Sitz des Befestigungs b gels zu achten Von au en herangef hrte PE Leitungen sind auf die daf r vorgesehene PE Klemme am Flansch anzuschlie en Ist eine seperate Au enerdung am Kunststoff geh use angebracht darf dieser Anschluss mit einer Leitung von max 25mm angeschlossen werden Dieser Au enerdungsanschluss ist innen im Ge h use f r einen Kabelschuhanschluss mit einem Loch f r M6 ausgelegt siehe auch Bild 10 Achtung Metallflansche Metallplatten und Metallverschraubungen m ssen in den Potentialausgleich miteinbezogen werden z Zt nicht bescheinigt f r Kategorie II D 6 5 Schlie en des Ger tes Alle Fremdk rper sind aus dem Ger t zu entfernen Die Einstellschraube zur Nennstromeinstellung am Schalteinsatz ist auf den Motornennstrom einzustellen Der Schaltgriff am Deckel des Motorschutz schalters muss in der gleichen Stellung stehen die er beim ffnen des Ger tes innehatte Beim Aufsetzen des Geh usedeckels ist darauf zu achten dass die Schaltachse des Schalteinsatzes korrekt in die Mitnehmer ffnung des Schaltgriffes eingef hrt wird Zur Sicherstellung der erforderlichen Mindest schutzart sind die Deckelschrauben fest anzuziehen Bei berm igem Anziehen kann die Schutzart beeintr chtigt werden 6 6 Inbetriebnahme Vor Inbetriebnahme des Betriebsmittels sind die in den einzelnen nat
10. Temperature class Min conductor cross section Input Output 0 10 0 75 m T 60 1 00 mm 2 50 1 50 mm 7 00 3 1 50 mm 2 00 A 2 50 mm 1250 2 50 mm 20 00 A 1 4 00 mm e COOPER Crouse Hinds 1 7 Setting range A A A Manual motor starters up to 25A GHG 635 Tripping current and tripping time Tripping time in seconds for 3 fold 4 fold 3 00 A 4 80A 7 56 A 14 00 A 22 40 A 35 00 A Al 6000A A 94 501 Al 135 00 A 187 50 Al 24000A Al 30000A Al 37500A Safety instructions The manual motor starters are not suitable for zone 0 and Zone 20 hazardous areas The temperature class and type of protection stated on the apparatus shall be observed The requirements of the EN 61241 0 and 1 regarding excessive dust deposits and temperature to be considered from the user Modifications or changes to the manual motor starters are not permitted They shall be used for their intended purpose and shall be in a perfect and clean state Only original COOPER Crouse Hinds parts may be used as replacements and for repairs Repairs that affect the explosion protection may only be carried out by COOPER Crouse Hinds or by a qualified electrician in compliance with the respective national regulations Prior to being put into operation the manual motor starters shall be checked in accordance with the instructions as per section 6 Before initial operation any foreign matter shal
11. a v rifier son fonctionnement et installation corrects en conformit avec ce mode d emploi et avec d autres r glements applicables L utilisation incorrecte de ces commutateurs peut annuler la garantie 7 Maintien Entretien La r glementation nationale en vigueur pour le maintien et entretien du mat riel lectrique pour atmosph re explosive doit tre respect e EN 60079 17 Avant ouverture de l enveloppe mettre l appareil hors tension et prendre les mesures pr ventives appropri es La fr quence des travaux d entretien requis d pendent de l emploi sp cifique et devront donc tre fix s par l utilisateur en tenant compte des conditions d utilisation Lors de l entretien des disjoncteurs surtout les composants qui sont essentiels leur mode de protection contre l explosion doivent tre v rifi s par ex int grit de composant antid flagrants et du boitier efficacit des joints de couvercle et resserrement des entr es de cable La fonction de remise du garrot de commutation doit galement tre v rifi e Si lors d un entretien on constate que des travaux de remise en tat sont n cessaires il faudra suivre le point 8 de ce mode d emploi 8 R parations Remise en tat Des r parations ne doivent tre ex cut es qu l aide des pi ces de rechange d origine COOPER Crouse Hinds En cas de d fauts sur l enveloppe antid flagrante seul un remplacement est admis
12. air Repairs that affect the explosion protection may only be carried out by COOPER Crouse Hinds or by a qualified electrician in compliance with the respective national regulations EN 60079 17 EN 60079 19 Apparatus modifications or design changes are not permitted excepted from this is the fitting of additional cable entries within the scope of the apparatus approvals 9 Disposal Recycling The respective valid national regulations for waste disposal shall be observed when disposing of apparatus To facilitate recycling of individual parts parts made of moulded plastic shall bear the marking for the type of plastic used The product range is subject to changes and additions COOPER Crouse Hinds Disjoncteurs moteur GHG 635 Pi Diagramme 1 Multiple de l intensit regl e d clenchement thermique d clenchement lectromagn tique Sch ma des connexions 40 DI dra 0 10 Td do Re N w N N AO e S COOPER Crouse Hinds Disjoncteurs moteur jusqu 25A GHG 635 1 Caract ristiques techniques 14 Disjoncteurs moteur GHG 635 Marquage selon 94 9 CE Classe de temperature voir point 1 6 page 4 Attestation d examen CE de type Tension nominale Courant nominal Fusible de court circuit Puissance de coupure AC 3 Caract ristique du d clenchement thermique Temp s de d clenchement Temp rature ambiante admissible D autres t
13. aubungen oder andere geeignete Einf hrungen mit zus tzlicher Zug entlastung zu verwenden Beim Einsatz von KLE mit einer niedrigeren als der f r das Ger t zutreffenden IP Schutzart siehe Seite 3 4 technische Daten wird die IP Schutzart des gesamten Ger tes reduziert Die f r die eingesetzten KLE ma gebenden Montagerichtlinien sind zu beachten Um die Mindestschutzart herzustellen sind nicht benutzte Einf hrungs ffnungen mit einem bescheinigten Verschluss Stopfen zu verschlie en Es ist darauf zu achten dass bei der Installati on der KLE die f r den Leitungsdurchmesser geeigneten Dichtungseins tze verwendet werden Bei ausschneidbaren Dichtungseins tzen ist sicherzustellen dass der Einsatz ordnungsge m dem Leitungsdurchmesser angepasst wird Zur Sicherstellung der erforderlichen Mindest schutzart sind die KLE fest anzuziehen Bei berm igem Anziehen kann die Schutzart beeintr chtigt werden Achtung Beim Anziehen der Hutmutter der Metall KLE z B Typ ADL ADE ist die Verschraubung mit einem geeigneten Werkzeug gegen Verdrehen zu sichern Alle nicht benutzten metrischen COOPER Crouse Hinds KLE sind mit dem bescheinig ten Verschluss f r metrische KLE zu ver schlie en e COOPER Crouse Hinds Motorschutzschalter bis 25A 6 4 Flansche Metallplatten und AuBenerdung M ssen Flanschplatten demontiert werden z B zum Bohren von Einf hrungs ffnungen ist bei der Montage zur
14. ausf hrung wird von den Ger ten erf llt Il mit Metallflansch Listenausf hrung 2x M25 f r Leitungen von 8 17mm 2 x M82 f r Leitungen von 12 21mm zus tzlich 1 x M25 2 x 0 75 4 Omm oder 1 x 10mm M20 M25 M32 M40 3 50 5 00 8 00 11 0 2 50 3 50 5 00 5 00 2 5 Nm 3 5 Nm 2 5 Nm 2 5 Nm ca 2 45 kg ca 2 55 kg bis 400V AC bis 2A 230V 2 A 400V 0 5 A 60V 2A 230V 0 25 A max 10 A gL 2 x 0 75 2 5 mm 110 V 230 V 400 V 500 V 50 60 Hz 35 75 von U gt 85 von U nicht erforderlich 2 x 0 75 2 5 mm m IM Motorschutzschalter bis 25A GHG 635 1 4 Gr ter Bemessungsstrom der Kurzschlussvorsicherung bei max 50 kA wenn lec gt les Kurzschlussfestigkeit und max Vorsicherung Einstellbereich 240 V AC 400V AC 500V AC 690V AC gL aM gL aM gL aM gL aM keine Vorsicherung notwendig bis I 50 kA 50A 80A 80A 25 kA 100A 22 kA 100A 20 kA 125A gt 13 1 5 Gr ter Bemessungsstrom der Kurzschlussvorsicherung bei max 100 kA wenn loc gt les Kurzschlussfestigkeit und max Vorsicherung Einstellbereich 240 VAC 400V AC 500V AC 690V AC gL aM gL aM gL aM gL aM keine Vorsicherung notwendig bis I 100 kA 40 kA TOKA 40 kA 50A 7 KA 30 kA 80A 5 kA 80A 27 kA 80A 4 5 kA 60 kA 100A 25 kA 100A 4kA 55 kA 100A 22 kA 100A 3 5 kA 50 kA 125A 20 kA 125A 3 kA i loc prospectiver Kurzschlussstrom am Einbauort log Bemessungsbetriebskurzschlussa
15. chnung nach 94 9 EG i Temperaturklasse siehe Punkt 1 6 Seite 4 EG Baumusterpr fbescheinigung Nennspannung Nennstrom Kurzschlussvorsicherung Schaltverm gen AC 3 Thermische Ausl secharakteristik Ausl sezeit Zul ssige Umgebungstemperatur Abweichende Temperaturen sind bei Sonderversionen m glich Zul Lagertemperatur in Originalverpackung Schutzart nach EN IEC 60529 Schutzklasse nach EN IEC 61140 Leitungseinf hrung 0 1A 6 3A 6 3A 25 0A mit Hilfskontakt Unterspannungsausl ser Anschlussklemme Pr fdrehmomente Druckschraube der KLE f r min Kabel in Nm f r max Kabel in Nm Deckelschrauben Anschlussklemmen Hauptkontakte Anschlussklemmen Hilfskontakte Anschlussklemmen Unterspannungsausl ser Gewicht Standardausf hrung mit Hilfskontakt Unterspannungsausl ser 1 2 Hilfskontakt Nennspannung Nennstrom Schaltverm gen AC 15 Schaltverm gen DC 13 Zulassige Kurzschlussvorsicherung Anschlussklemmen 1 3 Unterspannungsausl ser Nennspannungen Abfallwert Anzugswert Kurzschlussvorsicherung Anschlussklemmen Ma angaben in mm X Befestigungsma e I GHG 635 II 2 G Ex ed Il C T6 T5 amp Il 2 D Ex tD A21 IP66 80 C PTB 99 ATEX 1162 690 V 50 60 Hz 440V DC bis 25A siehe Punkt 1 4 und 1 5 Seite 4 690 V 25A TII Siehe Diagramm 1 S 3 sowie Punkt 1 7 S 5 20 C bis 40 C Listenausf hrung 40 C bis 80 C IP 66 Listen
16. emp ratures sont possibles avec des modeles sp ciaux Temp de stockage dans l emballage original Indice de protection selon EN CEI 60529 Classe d isolation selon EN CEI 61140 Entr es de cable 0 1A jusqu 6 3A 6 3A jusqu 25 0A avec contact auxiliaire d clencheur sur baisse de tension Bornes de connexion Couples de serrage test s Ecrou borgne bas de l entr e de cable M 25 Ecrou borgne bas de l entr e de cable M 32 Vis du couvercle Bornes de connexion principaux contact Bornes de connexion auxiliaires contact Bornes de connexion d clencheur min de tension Poids a vide mod le de standard avec contacts aux declencheur sur baisse de tension 1 2 Contacts auxiliaires Tension nominale Courant nominal Puissance de coupure AC 15 Puissance de coupure DC 13 Fusible de court circuit adm plac en amont Bornes de connexion 1 3 D clencheur a minimum de tension Tension nominale Valeur de chute Valeur d actionnement Fusible de court circuit adm plac en amont Bornes de connexion Dimensions en mm 140 X dimensions de fixation m II 2 G Ex ed Il C T6 T5 Il 2 D Ex tD A21 IP66 80 C PTB 99 ATEX 1162 690 V 50 60 Hz 440V DC jusqu 25 A voir point 1 4 et 1 5 page 4 jusqu 690 V 25 A Til voir diagramme 1 p 3 et point 1 7 p 5 20 C a 40 C modeles standard 50 C 80 C IP 66 mod les standard le dispositif rempli
17. ension 13 1 4 Courant max de court circuit du fusible pour max 50 KA 14 1 5 Courant max de court circuit du fusible pour max 100 KA 14 1 6 Classe de temp rature et diametre des conducteurs 14 1 7 Courant et temps de d clenchement 15 2 Consignes de s curit 15 3 Conformit avec les elen 15 4 Domaine d utilisation 2 15 5 Utilisation Propri t s 15 6 Installation a 16 6 1 Montage EE 16 6 2 Ouverture de l appareil Raccordement lectrique 16 6 3 Entr es de cable KLE bouchons de fermeture a 6 4 Plaques brides 6 5 Fermeture de l appareil Fermeture du couvercle 17 6 6 Mise en service a 7 7 Maintien Entretien 17 8 R paration Remise en tat Modifications 17 9 vacuation des d chets Recyclage a 17 10 D claration de conformite 18 COOPER Crouse Hinds Motorschutzschalter GHG 635 Ta Diagramm 1 f 8 BA EE LE 5 N oO Hd 0 a lt NZ HARRIS ALL UI Vielfaches des Einstellstromes te 1 thermische Ausl sung 2 elektromagnetische Ausl sung Anschlussbild 40 si dr 0 10 Td do Re N Di N N AO e S COOPER Crouse Hinds Motorschutzschalter bis 25A 1 Technische Angaben 1 1 Motorschutzschalter GHG 635 Geratekennzei
18. functioning of the apparatus and installation of the apparatus shall be checked in accordance with these operating instructions and other applicable regulations The improper operation of manual motor starters may result in the invalidation of the guarantee 7 Maintenance Servicing The valid national regulations for the servicing maintenance of electrical apparatus for use in potentially explosive atmospheres shall be observed EN 60079 17 Prior to opening the enclosure it is necessary to ensure that the voltage supply has been isolated or to take suitable protective measures The necessary intervals between servicing depend upon the specific application and shall be stipulated by the operator according to the respective operating conditions During servicing above all the parts on which the explosion protection depend e g intactness of the flameproof components the enclosure the seals and cable entries and the reset function of the switch handle shall be checked If in the course of servicing it is ascertained that repairs are necessary section 8 of these operating instructions shall be observed 8 Repairs Overhaul Modification Only original COOPER Crouse Hinds parts shall be used for carrying out repairs In the event of damage to the flameproof encapsulation replacement of these components is mandatory In case of doubt the respective apparatus shall be sent to COOPER Crouse Hinds for rep
19. ie Aderenden entspre chend den geltenden nationalen und interna tionalen Vorschriften zu behandeln z B Verwendung von Aderendh lsen Die Lage der Anschlussklemmen entnehmen Sie dem Anschlussbild des Schalteinsatzes und der Darstellung Seite 3 technische Daten Um ein korrektes Schlie en des Motorschutz schalters zu gew hrleisten ist ein Schalten an der Schaltachse des Schalteinsatzes bei ge ffnetem Ger t nicht zul ssig Wird der Schalteinsatz zum leichteren Einf hren der Anschlussleitungen in das Geh use an den Schnappriegeln oben oder unten am Einsatz aus der Profilschiene am Geh useboden ausgeschnappt muss vor dem elektrischen Anschluss der Schalteinsatz wieder ordnungsgem in das Geh useunter teil eingeschnappt werden Der Endhalter auf der Profilschiene dient zur Fixierung des Schalteinsatzes auf der Schiene und darf auf keinen Fall demontiert werden Der Anschluss des Unterspannungsausl sers ist generell auf separate Klemmen gef hrt siehe Anschlussplan Seite 3 technische Daten Die daf r vom Einsatzfall abh ngige Verdrahtung des Unterspannungsausl sers ist vom Anwender durchzuf hren COOPER Crouse Hinds AuBenerdung Geh use innenwand bee Erdungsplatte Innenerdungs anschluss 6 3 Kabel undLeitungseinfi h rungen KLE Verschluss Stopfen Es d rfen generell nur bescheinigte KLE und Verschluss Stopfen verwendet werden Fur bewegliche Leitungen sind Trompeten verschr
20. ionalen Bestimmungen genannten Pr fungen durchzuf hren Ausserdem ist vor der Inbetriebnahme die korrekte Funktion und Installation des Betriebsmit tels in bereinstimmung mit dieser Betriebsanlei tung und anderen anwendbaren Bestimmungen zu berpr fen Unsachgem er Betrieb der Motorschutz schalter kann zum Verlust der Garantie f hren GHG 635 7 Instandhaltung Wartung Die f r die Wartung Instandhaltung von elektrischen Betriebsmitteln in explosions gef hrdeten Bereichen geltenden nationa len Bestimmungen sind einzuhalten EN 600079 17 Vor ffnen des Geh uses Spannungs freiheit sicherstellen oder geeignete Schutzma nahmen ergreifen Die erforderlichen Wartungsintervalle sind anwendungsspezifisch und daher in Abh ngigkeit von den Einsatzbedingungen vom Betreiber festzulegen Im Rahmen der Wartung sind vor allem die Teile von denen die Z ndschutzart abh ngt zu pr fen z B Unversehrtheit der druckfesten Komponen ten des Geh uses der Dichtungen und der Kabel und Leitungseinf hrung sowie die R ckstellfunktion des Schaltgriffes Sollte bei einer Wartung festgestellt werden dass Instandsetzungsarbeiten erforderlich sind ist Abschnitt 8 dieser Betriebsanleitung zu beachten 8 Reparatur Instand setzung nderungen Instandsetzungsarbeiten Reparaturen d rfen nur mit COOPER Crouse Hinds Originaler satzteilen vorgenommen werden Bei Sch den an der druckfesten Kapselung ist nu
21. is et ou crous des bornes de connexion ainsi que celles des bornes non utilis es doivent tre serr es a fond Un serrage excessif des vis peut endommager l appareil Les bornes sont pr vues pour le raccordement de conducteurs en cuivre En cas d utilisation de cables de connexion multifilaires ou a fils de petit diametre les extremites de fil doivent amp tre trait selon la reglementation nationale et internationale applicable par ex emploi des embouts La disposition des bornes de connexion est repr sent e par la figure des connexions du socle et par celle de la page 13 Caract ristiques techniques Afin de s assurer une fermeture correcte du disjoncteur moteur une commutation de Taxe du socle n est pas permise Si du fait de l introduction des conducteurs dans l enveloppe le socle venait a amp tre legerement deloge vers le haut ou le bas de son rail de fixation celui ci devrait tre remis en place correctement sur ce rail avant toute connexion lectrique Le support du rail sert a la fixation du socle de l interrupteur sur ce dernier et ne doit en aucun cas tre d mont Le raccordement du d clencheur sur basse tension se fait de mani re g n rale sur des bornes a part voir plan de raccordement page 3 Caract ristiques techniques Le cablage du d clencheur sur basse tension variable selon l utilisation sera effectu par l utilisateur lui m me 6 3 Entr es de c b
22. l be removed from the apparatus Warning Observe the terminal cross sections of the manual motor starters in table 1 6 page 9 The national safety rules and regulations for the prevention of accidents as well as the safety instructions included in these operating instructions that like this text are set in italics shall be observed 3 Conformity with standards The apparat is conform to the standards specified in the EC Declaration of conformity It has been designed manufactured and tested according to the state of the art and to DIN EN ISO 9001 94 9 EC Equipment and protective systems intended for use in potentially explosive atmospheres The control units fulfil further requirements such as the EC directive on electromagnetic compatibility 2004 108 EC 4 Field of application The manual motor starters are suitable for use in zone 1 2 and 21 22 hazardous areas acc to IEC 60079 10 The enclosure materials employed including the exterior metal parts are made of high quality materials which ensure a corrosion protection and resistance to chemical substances corresponding to the requirements in a normal industrial atmosphere glass fibre reinforced polyester impact resistant polyamide special steel AISI 316 L In case of use in an extremely aggresive atmosphere please refer to manufacturer fold setting current 5 fold 6 fold 8 fold 5 Application Properties The manual motor
23. le Bouchons de fermeture G n ralement seuls des bouchons de fermeture et des entr es de c ble certifi s doivent tre utilis s Pour des c bles flexibles il faudra utiliser des presse toupes en forme de trompette ou d autres entr es appropri es avec d charge de traction suppl mentaire Lorsque des entr es de c ble avec un indice de protection IP inf rieur celui de les disjoncteurs moteurs sont employ es voir page 3 l indice de protection IP de l ensemble sera r duit Les directives pour le montage qui s appliquent aux entr es de c ble utilis es doivent tre respect es e COOPER Crouse Hinds Les entr es non utilis es doivent tre ferm es avec un bouchon de fermeture certifi pour tablir l indice de protection minimum Lors du montage des entr es de cable il faudra veiller a ce que des garnitures d tanch it correspondant au diam tre du cable soient utilis es Si les garnitures doivent amp tre coup es sur mesure il faudra veiller a ce que celles ci s adaptent parfaitement au diam tre du cable Les entr es de cable doivent tre serr es a fond pour maintenir l indice de protection minimum Au cas ou elles seraient forc es cela pourrait tre nuisible a l indice de protection Toutes les entr es de cable m triques COOPER Crouse Hinds non utilis es doivent tre ferm es avec un bouchon de fermeture certifi pour des entr es de c ble m triques
24. ll A CEAG Betriebsanleitung Explosionsgesch tzte Motorschutzschalter bis E 25A GHG 635 Operating instructions Explosion protected manual motor starters up to 25A GHG 635 Mode d emploi Disjoncteurs moteur jusqu 25A GHG 635 pour atmospheres explosibles COOPER Crouse Hinds GHG 630 7011 P0003 D E F E Explosionsgeschutzter Motorschutzschalter bis 25A GHG 635 Inhalt nn A 5 amp D 1 5 10 Technische Angaben a3 Motorschutzschalter 50 Hilfskontakt 3 Unterspannungsausl ser 3 Gr ter Bemessungsstrom der Kurzschlussvorsicherung bei max 50 KA eee 4 Gr ter Bemessungsstrom der Kurzschlussvorsicherung bei max 100 KA 4 Temperaturklasse und Verdrahtungsquerschnitt 4 Ausl sestrom und Ausl sezeit tri Sicherheitshinweise Normenkonformitat Verwendungsbereich Verwendung Eigenschaften 9 Installation i 6 Montage EE 6 ffnen des Ger tes Elektrischer Anschluss 6 Kabel und Leitungs einf hrung Verschluss ele 6 7 Flansche und Metallplatten 7 Schlie en des Ger tes Inbetriebnahme Instandhaltung Wartung Reparatur Instandsetzung nderungen s s ssssiesirsrrsneneene 7 Entsorgung Wieder Verwertung Konformit tserkl rung Explosion protected manual motor starters up to 25 A GHG
25. lla EU n kielell Teid n Cooper Crouse Hinds CEAG edustajaltanne GR Eav xpeiao8el pera paon TWV O NYIWV XPNOE Ws o aAAn y wooa Tng EE prope va Zntnde atto tov AVTITPOOWTTO Tng Cooper Crouse Hinds CEAG H A kezel si tmutat t az adott orsz g nyelv n a Cooper Crouse Hinds CEAG c g helyi k pviselet n ig nyelheti meg I Se desiderate la traduzione del manuale operativo in un altra lingua della Comunit Europea potete richiederla al vostro rappresentante Cooper Crouse Hinds CEAG LT ios naudojimo instrukcijos i verstos J s gimtaja kalb galite pareikalauti atsakingoje Cooper Crouse Hinds CEAG atstovybeje savo alyje LV o ekspluat cijas instrukciju valsts valod varat piepras t jusu valsts atbildigaj Cooper Crouse Hinds CEAG p rst vniec b M Jistg u jitolbu dan il manwal fil lingwa nazzjonali tag hom ming and ir rappre entant ta Cooper Crouse Hinds CEAG f pajji hom NL Indien noodzakelijk kan de vertaling van deze gebruiksinstructie in een andere EU taal worden opgevraagd bij Uw Cooper Crouse Hinds CEAG vertegenwoordiging COOPER Crouse Hinds GmbH Neuer Weg Nord 49 D 69412 Eberbach Germany Fone 0049 0 6271 806 500 Fax 0049 0 6271 806 476 Internet www ceag de E Mail Info ex ceag de P Se for necess ria a tradu o destas instrug es de operac o para outro idioma da Uni o Europeia pode solicita la junto do seu representan
26. ns Des r parations portant sur la protection contre l explosion ne devront tre ex cut es que par COOPER Crouse Hinds ou par un lectricien qualifi en conformit avec la r glementation nationale en vigueur Avant la mise en service les disjoncteurs moteurs doivent tre v rifi s selon les instructions expos es donn e dans la section 6 Avant la premi re mise en service tout corps tranger doit tre te de l appareil Attention Respecter les sections de raccord du disjoncteur moteur selon le point 1 6 page 15 Respectez les prescriptions nationales de s curit et de pr voyance contre les accidents ainsi que les consignes de s curit qui suivent dans ce mode d emploi et qui sont mises en italique comme ce texte e COOPER Crouse Hinds 3 Conformit avec les normes Les bo tes bornes ont t con ues fabriqu es et contr l es suivant DIN EN ISO 9001 Les Appareils sont conformes aux normes reprises dans la d claration de conformit 94 9 CE Appareils et syst mes de protection destin s tre utilis s en atmosph re explosible De Appareils de commande r pondent d autres exigences comme par exemple celles de la directive CE Compatibilit lectromagn tique 2004 108 CEE 4 Domaine d utilisation Les disjoncteurs moteur conviennent a l emploi en zones 1 2 et 21 22 d une atmosph re explosive selon CEI 60079 10 Pour l enveloppe et les pieces m
27. ontage des disjoncteurs moteurs peut se faire sans ouvrir l enveloppe Dans le cas d un montage directement au mur les disjoncteurs moteurs ne doivent reposer au niveau du mur que sur les points de fixation pr vus La vis choisie doit amp tre en rapport avec le trou de fixation voir plan cot et ne doit pas avarier le trou par ex emploi d une rondelle L appareil doit amp tre fix en diagonale avec au moins 2 vis Un serrage excessif des vis de fixation peut endommager l appareil Le montage des disjoncteurs moteur se fait sur les plaques de fixation COOPER Crouse Hinds taille 3 par insertion par le haut dans les encoches pr vues a cet effet Reportez vous a la notice de montage correspondante 6 2 Ouverture de l appareil Raccordement lectrique Avant ouverture de l enveloppe mettre l appareil hors tension et prendre les mesures pr ventives appropri es Le raccordement lectrique de l appareil ne doit se faire que par un personnel qualifi Le raccordement des cables d nud s se fera selon les r glements correspondants Afin de maintenir le mode de protection la connexion des conducteurs doit se faire tr s soigneusement L isolation doit couvrir le conducteur jusqu a la borne Le conducteur lui m me ne doit pas tre endommag Les sections minimales et maximales admissibles des conducteurs doivent tre respect es voir caract ristiques techniques point 1 6 Toutes les v
28. or these metric cable entries 6 4 Flange and metal plates If flange plates have to be dismantled e g to drill entry holes when replacing the plates in order to maintain the minimum degree of protection it is necessary to ensure that the flange plate and the fixing clamp fit correctly PE conductors fed from outside shall be connected to the PE terminal provided on the flange Warning Metal flanges metal plates and metal glands shall be incorporated in the potential equalization not yet certified for category IID 6 5 Closing apparatus Cover closure Any foreign matter shall be removed from the apparatus The setting screw on the switch insert for setting the rated current shall be set to the rated motor current The switch handle on the cover of the manual motor starter shall be in the position it had when the apparatus was opened When fitting the apparatus cover care shall be taken to ensure that the switch shaft of the switch insert engages correctly in the carrier hole of the switch handle To ensure the required minimum degree of protection the cover screws shall be tightened down Overtightening may impair the degree of protection Manual motor starters up to 25A GHG 635 6 6 Putting into operation Before putting the apparatus into operation the tests specified in the individual national regulations shall be performed In addition to this before being put into operation the correct
29. osionsschutz und Chemikalienresistenz in normaler Industrieatmosph re gew hrleisten schlagfestes Polyamid glasfaserverst rktes Polyester Edelstahl AISI 316 L Bei einem Einsatz in extrem aggressiver Atmosph re k nnen Sie zus tzliche Informa tionen ber die Chemikalienbest ndigkeit der eingesetzten Kunststoffe bei Ihrer zust ndi gen Cooper Crouse Hinds Niederlassung erfragen 5 Verwendung Eigenschaften Die Motorschutzschalter dienen zum Schutz von explosionsgesch tzten Motoren in jeder Z ndschutzart vor berlast und Phasenaus fall Temperaturklasse Explosionsgruppe Ausl secharakteristik und zul ssige Umgebungstemperatur sowie das Ausl se diagramm sind aus den technischen Daten zu entnehmen Durch das AC 3 Motorschaltverm gen der Motorschutzschalter ist eine sichere Trennung Schalten auch w hrend des Betriebes m glich Die Verwendung eines Unterspannungs ausl sers verhindert das selbstst ndige Anlaufen des Motores Dar ber hinaus kann der Unterspannungsausl ser zur Abschaltung im Not Aus Stromkreis verwendet werden Der Hilfskontakt optional dient haupts chlich zur Signalgebung des Motorschutzschalter betriebszustandes Der Motorschutzschalter kann in AUS Stellung mit 3 Vorh ngeschl sser gegen unbefugtes Schalten gesichert werden B geldurchmesser der Vorh ngeschl sser von 4 6mm siehe Bild 1 Ger tehalter f r Rohrbefestigung Gr e 3 A Steckbefestigungspunkte
30. pe fixing size 3 A fixing point for manual motor starter Apparatus holder for wall and channel fixing size 3 A fixing points for manual motor starter S COOPER Crouse Hinds Manual motor starters up to 25A GHG 635 6 Installation The relevant national regulations e g Elex V the equipment safety law for Germany and the generally recognized rules of engineering apply for the installation and operation The improper installation and operation of manual motor starters may result in the invalidation of the guarantee 6 1 Montage The manual motor starter can be mounted without opening the enclosure When the manual motor starters are mounted directly onto the wall they shall rest evenly only on the fastening points provided for this purpose The screw chosen shall fit the fixing hole see dimensional drawing and shall not damage the hole e g use of a washer If the screws are overtightened the apparatus may be damaged The manual motor starters are suited for plug in mounting on COOPER Crouse Hinds apparatus holders size 3 whereby they are pushed into the guide groove from the top of the apparatus holder See the respective mounting instructions 6 2 Opening apparatus Electrical connection Before opening the apparatus it is necessary to ensure that there is no voltage or to take suitable protective measures The electrical connection of the may only be carried out by specialists
31. r ein Austausch zul ssig Im Zweifels falle ist das betroffene Betriebsmittel an COOPER Crouse Hinds zur Reparatur zur ckzugeben Reparaturen die den Explosionsschutz betreffen d rfen nur von COOPER Crouse Hinds oder einer qualifizierten Elektrofachkraft in bereinstimmung mit national geltenden Regeln durchgef hrt werden EN 60079 17 EN 60079 19 Umbauten oder nderungen am Betriebsmittel sind nicht gestattet ausgenommen ist das Anbringen von zus tzlichen KLE s im Rahmen der Zulassung des Betriebsmittels 9 Entsorgung Wiederver wertung Bei der Entsorgung des Betriebsmittels sind die jeweils geltenden nationalen Abfallbeseitigungs vorschriften zu beachten Zur Erleichterung der Wiederverwertbarkeit von Einzelteilen sind Kunststoffteile mit dem Kennzei chen des verwendeten Kunststoffes versehen Programm nderungen und erg nzungen sind vorbehalten Manual motor starter GHG 635 Tripping tim CoA UTE TTT UR IO WET TR IL TI ILT d i Multiple of setting current thermal tripping electromagnetic tripping Manual motor starters up to 25A GHG 635 1 Technical data 1 1 Manual motor starters GHG 635 Marking acc to 94 9 EC iz Temperature class see 1 6 page 9 EC type examination certificate Rated voltage Rated current Short circuit back up fuse AC 3 switching capacity Thermal tripping characteristic Tripping time Perm storage temperature in original packing
32. s cette condition Il avec plaque m talique modeles standard 2 x M25 pour c bles de 8 17 mm 2 x M32 pour cables de 12 21 mm 1 x M25 en suppl ment 2x0 75 4 0mm ou 1 x 10 mm 3 5 Nm 5 0 Nm 2 5 Nm 3 5 Nm 2 5 Nm 2 5 Nm env 2 45 kg env 2 55 kg jusqu 400 V AC jusqu 2A 230V 2A 60V 2A 10 A gl maxi SU ZIO ine 400 V 0 5 A 230V 0 25 A 110 V 230 V 400 V 500 V 50 60 Hz 35 75 von U gt 85 von U non n cessaire 2 x 0 75 2 5 mm 225 x 197 Disjoncteurs moteurs jusqu 25A GHG 635 1 4 Courant max de court circuit du fusible pour max 50 kA pour Icc gt Ics R sistance aux court circuits et fusible maximum plac en amont Plage de r glage 240 V AC 400V AC 500V AC 690V AC gL aM gL aM gL aM gL aM R sistant aux courts circuits fusible plac en amont non n cessaire jusqu I 50 kA 50A 80A 80A 25 kA 100A 22 kA 100A 20 kA 125A SIS 1 5 Courant max de court circuit du fusible pour max 100 kA pour Icc gt Ics R sistance aux court circuits et fusible maximum plac en amont Plage de r glage 240 V AC 400V AC 500V AC 690V AC gL aM gL aM gL aM gL aM R sistant aux courts circuits fusible plac en amont non n cessaire jusqu I 100 kA 40 kA TOKA 40 kA 50A 7kA 30 kA 80A 5 kA 80A 27 kA 80A 4 5 kA I soka 1004 25kA 100A 4 KA I 55kA 100A 22kA 100A 3 5 KA I 50kA 125A 20kA 125A 3 kA loc courant de court circuit pr
33. sible Dans le doute l appareil d fectueux devra tre renvoy COOPER Crouse Hinds pour tre r par Des r parations qui portent sur la protection contre l explosion ne devront tre ex cut es que par COOPER Crouse Hinds ou par un lectricien qualifi en conformit avec la r glementation nationale en vigueur EN 60079 17 EN 60079 19 Il n est pas permis de transformer ou de modifier ces appareils sauf pour le montage des entr es de c ble suppl mentaires en conformit avec leur homologation 9 vacuation des d chets Recyclage Lors de l vacuation de ce mat riel lectrique la r glementation nationale respective en vigueur devra tre respect e Pour faciliter la r utilisation des composants individuels les pi ces en plastique ont t rep r es de la marque distinctive de la mati re plastique employ e Sous r serve de modification ou d informations suppl mentaires EG Konformitatserklarung EC Declaration of conformity CE D claration de conformite PTB 99 ATEX 1162 GHG 900 1000 P0029 C Cal COOPER Crouse Hinds Wir we nous Cooper Crouse Hinds GmbH Neuer Weg Nord 49 D 69412 Eberbach erkl ren in alleiniger Verantwortung dass die Motorschutzschalter hereby declare in our sole responsibility that the manual motor starters d clarons de notre seule responsabilit que le disjoncteurs moteur commande manuelle 112G Exe dilC T5 bzw T6 Typ GHG 63 1 R 112D E
34. starters are used for the protection of explosion protected motors regardless of the explosion category against overload and phase failure The temperature class explosion group tripping characteristic and permissible ambient temperature can be found in the technical data Due to the AC 3 motor switching capacity of the manual motor starter a safe and reliable isolation switching is also possible during operation The use of an undervoltage trip prevents the self starting of the motor In addition the undervoltage trip can be used for disconnecting emergency circuits The auxiliary contact optional is mainly used for signalling the operating state of the manual motor starter To safeguard the manual motor starter against unauthorized use it can be locked in the OFF position by means of 3 padlocking facilities shackle diameter of padlocks up to 5 mm The data according to sections 3 and 4 shall be taken into account during use Applications other than those described are not permissible without a written declaration of consent from Messrs COOPER Crouse Hinds During operation the instructions stated in section 7 of the operating instructions shall be observed The sole responsibility with respect to the suitability and proper use of the manual motor starters with regard to the basic requirements of these instructions see technical data lies with the operator ee COOPER Crouse Hinds Apparatus holder for pi
35. tact auxiliaire en option sert principalement a donner un signal relatif a l tat de fonctionnent du disjoncteur moteur Le disjoncteur moteur peut en position OFF tre dot de trois cadenas pr venant ainsi tout risque de mise hors tension non autoris e diam tre de l trier jusqu a 5mm Pour l emploi les consignes des sections 3 et 4 devront tre respect es Des emplois autres que ceux d crits ne sont admis qu avec l approbation crite de COOPER Crouse Hinds Lors de l utilisation les instructions selon point 7 de ce mode d emploi doivent tre respect es Seul l utilisateur est responsable de l emploi comme pr vu de disjoncteur moteur en tenant compte des conditions g n rales existant dans l tablissement voir Caract ristiques techniques Plaque de fixation sur tube taille 3 A points de fixation pour disjoncteurs moteur Plaque de fixation au mur sur grillage taille 3 A points de fixation pour disjoncteurs moteur Disjoncteurs moteur jusqu 25A GHG 635 6 Installation Pour l installation et l exploitation de ces appareils la reglementation nationale en vigueur en Allemagne par ex ElexV loi de s curit des appareils ainsi que les r gles de la technique g n ralement reconnues devront tre respect es L installation ou l utilisation incorrecte de ces disjoncteurs moteurs a bornes peut entrainer la perte de la garantie 6 1 Montage Le m
36. talliques exterieures des matieres de qualit sup rieure qui assurent une protection appropri e contre la corrosion et une r sistance contre des agents chimiques en atmosph re industrielle normale ont t employ es polyester charg verre polyamide anti choc acier special AISI 316 L En cas d utilisation en atmosph re extremement corrosive vous pouvez obtenir des informations compl mentaires sur la r sistance chimique des plastiques utilis s chez la succursale Cooper Crouse Hinds de votre r gion Temps de d clenchement en sec selon la multiplicit du r glage du 5 fois 6 fois 8 fois 5 Utilisation Propri t s Les disjoncteurs moteur servent a prot ger les moteurs Ex pour tout type de protection contre explosion d ventuelles surcharges et pertes de phase Les informations relatives a la classe de temp rature au groupe d explosion aux caract ristiques de d clenchement a la temp rature ambiante admise ainsi que le diagramme de d clenchement figurent dans les donn es techniques Avec la puissance de coupure AC 3 du disjoncteur moteur une disjonction peut tre effectu e en toute s curit pendant le fonctionnement de l installation lectrique L utilisation d un d clencheur sur baisse de tension emp che un demarrage ind pendant du moteur En outre le d clencheur sur baisse de tension peut tre employ pour mettre hors circuit sur le mode arr t d urgence Le con
37. te Cooper Crouse Hinds CEAG PL Niniejszainstrukcj amp obstugi w odpowiedniej wersji jezykowej mo na zam wi w przedstawicielstwie firmy Cooper Crouse Hinds CEAG na dany kraj S En vers ttning av denna montage och sk tselinstruktion till annat EU spr k kan vid behov best llas fr n Er Cooper Crouse Hinds CEAG representant SK Tento n vod na obsluhu V m vo Va om rodnom jazyku poskytne zast penie spolo nosti Cooper Crouse Hinds CEAG vo Va ej krajine SLO Navodila za uporabo v Va em jeziku lahko zahtevate pri pristojnem zastopni tvu podjetja Cooper Crouse Hinds CEAG v Va i dr avi GHG 630 7011 P0003 D E F E Auflage 05 08 Zi
38. usschaltverm gen 1 6 Temperaturklasse und Verdrahtungsquerschnitt Einstellbereich Temperaturklasse Mindestanschlussquerschnitt Zugang Abgang 0 10A 0 75 mm 0 75 mm 1 60 A 1 00 mm 1 00 mm 2 50A ae 1 00 mm 1 50 mm 4 00 A ee 1 50 mm2 1 50 mm 9 00A ee 2 50 mm 2 50 mm 12 50A een 2 50 mm 2 50 mm 20 00 A 4 00 mm 4 00 mm ee COOPER Crouse Hinds Motorschutzschalter bis 25A GHG 635 1 7 Ausl sestrom und Ausl sezeit Einstellbereich Ausl sezeit in Sekunden bei fachen des Einstellstromes 3 fach 4 fach 5 fach 6 fach 8 fach 0 16 A 1 92A 0 25 A 0 40 A 0 63 A 3 00 A 4 80A 7 56 A 1 00 A 14 00 A 1 60 A 2 50 A 22 40A 35 00 A A00Al 60 00 530Al 94 50 B00 Al 135 00 T250 A 187 50 16 00A 24000 20 00 Al 300 00 25 00 Al 37500A 2 Sicherheitshinweise Die Motorschutzschalter sind nicht f r Zone 0 und 20 geeignet Die auf den Ger ten angegebene Temperaturklasse und Z ndschutzart ist zu beachten Die Anforderungen der EN 61241 0 und 1 u a in Bezug auf berm ige Staubab lagerungen und Temperatur sind vom Anwender zu beachten Umbauten oder Ver nderungen an den Motorschutzschaltern sind nicht gestattet Sie sind bestimmungsgem in unbesch digtem und einwandfreiem Zustand zu be treiben Als Ersatz und zur Reparatur d rfen nur Originalteile von COOPER Crouse Hinds ver wendet werden Reparaturen die den Explosionsschutz betreffen d rfen nur
39. x 2 55 kg up to 400V AC up to 2A 230V 2A 60V 2A max 10 A gL 2 x 0 75 2 5 mm 400 V 0 50 A 230 V 0 25 A 110 V 230 V 400 V 500 V 50 60 Hz 35 75 E gt 85 Ec not necessary 2 x 0 75 2 5 mm Cc Wiring diagram X 126 i a g 225 X 197 I I b e EE D eeh O cuni o 0 1 g mn gt N N w N N gt e e COOPER Crouse Hinds Manual motor starters up to 25A GHG 635 1 4 Maximum rating current for short circuit back up fuse for max 50 KA if loc gt les Short circuit protection and max back up fuse Setting range 240 V AC 400V AC 500V AC 690V AC gL gG gL gG gL gG gL gG Short circuit proof no back up fuse required up to I 50 kA 50A 80A 80A 25 kA 100A 22 kA 100A 20 kA 125A SIS 1 5 Maximum rating current for short circuit back up fuse for max 100 kA if loc gt les Short circuit protection and max back up fuse Setting range 240 VAC 400V AC 500V AC 690V AC gL gG gL gG gL gG gL gG Short circuit proof no back up fuse required up to I 100 kA 40 kA TOKA 40 kA 50A 7 KA 30 kA 80A 5 kA 80A 27 kA 80A 4 5 kA 60 kA 100A 25 kA 100A 4kA 55 kA 100A 22 kA 100A 3 5 kA 50 kA 125A 20 kA 125A 3 kA log Prospective short circuit current at installation location log Rated short circuit breaking capacity 1 6 Temperature class and conductor cross section Setting range
40. x tD A21 IP66 T 80 C auf die sich diese Erkl rung bezieht mit den folgenden Normen oder normativen Dokumenten bereinstimmen which are the subject of this declaration are in conformity with the following standards or normative documents auquel cette d claration se rapporte est conforme aux nomes ou aux documents normatifs suivants Bestimmungen der Richtlinie Titel und oder Nr sowie Ausgabedatum der Norm Terms of the directive Title and or No and date of issue of the standard Prescription de la directive Titre et ou No ainsi que date d mission des normes 94 9 EG Ger te und Schutzsysteme zur bestimmungs EN 60 079 0 2006 gem en Verwendung in explosionsgefahrdeten EN 60 079 1 2004 Bereichen EN 60 079 7 2007 EN 61 241 0 2006 94 9 EC Equipment and protective systems intended for EN 61 241 1 2004 use in potentially explosive atmospheres EN 60 529 1991 A1 2000 EN 60 999 1 2000 94 9 CE Appareils et systemes de protection destin s a EN 60 947 3 1999 A1 2001 A2 2005 tre utilis s en atmosph re explosibles 2004 108 EG Elektromagnetische Vertr glichkeit EN 60 947 1 2004 Corr 2004 2004 108 EC Electromagnetic compatibility 2004 108 CE Compatibilit lectromagn tique Eberbach den 14 04 2008 iA R Brandel Ort und Datum Leiter Labor Place and date Head of Laboratory Head of Approval office Lieu et date Chef du d pt Laboratoire Chef du d pt approbation PTB 96 ATEX Q 1 4 Q001
41. xing the switch insert on the rail and shall not be dismounted under any circumstances The undervoltage trip is generally connected to separate terminals see wiring diagram on page 8 technical data Wiring of the undervoltage trip according to the individual application shall be carried out by the user 6 3 Cable entries KLE blanking plugs Generally only certified cable entries and blanking plugs may be used Flexible cables shall be used with trumpet shaped cable glands or other suitable entries with additional pull relief When using cable entries with a degree of protection that is lower than the IP protection of the apparatus see page 8 the degree of IP protection for the complete unit is reduced The relevant mounting directives for cables entries being used shall be observed In order to ensure the minimum degree of protection any unused entry holes shall be sealed with certified blanking plugs When fitting cable entries care has to be taken that the sealing inserts are suitable for the cable diameter In the case of sealing inserts that are cut out it is necessary to ensure that the insert is properly adapted to the cable diameter In order to ensure the required minimum degree of protection the cable entries shall be tightened down securely Overtightening can impair the degree of protection Any unused metric COOPER Crouse Hinds cable entries shall be sealed with the blanking plug certified f
42. zu befestigen Bei berm igem Anziehen der Befestigungsschrauben kann das Ger t besch digt werden Die Motorschutzschalter sind zur Steck befestigung auf dem COOPER Crouse Hinds Ger tehalter Gr sse 3 durch Einschieben in die F hrungsnut von oben des Ger tehalters geeignet Die betreffende Montageanleitung ist zu beachten 6 2 ffnen des Ger tes Elektrischer Anschluss Vor ffnen der Ger te ist die Spannungs freiheit sicherzustellen bzw sind geignete Schutzma nahmen zu ergreifen GHG 635 Der elektrische Anschluss des Betriebsmit tels darf nur durch Fachpersonal erfolgen Die ordnungsgem abisolierten Anschluss leitungen der Kabel sind unter Ber cksichti gung einschl giger Vorschriften anzuschlie en Zur Aufrechterhaltung der Z ndschutzart ist der Leiteranschluss mit besonderer Sorgfalt durchzuf hren Die Isolation der Anschlussleitungen muss bis an die Klemme heranreichen Der Leiter selbst darf nicht besch digt sein Die minimal und maximal anschlie baren Leiterquerschnitte sind zu beachten siehe Punkt 1 6 technische Daten Alle Schrauben und oder Muttern der Anschlussklemmen auch die der nicht benutzten sind fest anzuziehen Bei berm igem Anziehen kann der Anschluss beeintr chtigt oder besch digt werden Die Anschlussklemmen sind f r den Anschluss von Kupferleitern ausgelegt Bei der Verwen dung von mehr oder feindr htigen Anschluss kabel leitungen sind d