        Operating Instructions for FS 345 with FS 101 and CS300 FS
         Contents
1.              MFZ MFZOVITOR    The FS101 circuit board includes a charger for the rechargeable battery and a microprocessor for  controlling the auxiliary drive or the engine brake    The circuit board is connected to the CS300ME door control unit in the factory and if it is purchased  together with a door operator  the correct settings for that operator are also preset in the factory    All that remains to be connected is a fire alarm  and the rechargeable battery must be connected to the  FS101 circuit board via a plug                 lt                    Circuit board  FS101    Accu                Accu C p      To prevent deep discharge of the rechargeable battery  the battery should not be                               connected to the FS101 circuit board until the door is put into operation      gt         Warning   To ensure that the equipment functions properly  the following conditions must be assured     The door is installed and operational       The command and safety devices are installed and ready for operation     The control unit housing with the FS345 controls is installed     All motor connections are secured at the motor and the controls       All components to be connected to the controls must have at least one additional isolation with a  rated voltage of more than 230 V     Information   For the installation of the door and the command and safety devices  the relevant manufacturers          instructions must be adhered to     Mains connection   F   Danger
2.    To guarantee that the controls function properly  the following points must be  ensured      The mains voltage must correspond to the voltage stated on the type plate     For a permanent connection  an all pole mains switch must be used            MFZOVITOR    CS 300FS           o    Connect the controls to the mains supply     Connect the controls to the motor     a x                                                                                                                                                                                  Legend     Connection     Contactor CLOSED  Contactor OPEN    Motor    K1     K2     M1     The groups of cables must be fixed together     gt     Transformer    11   X1     close to their relevant terminals using a cable tie     Terminal block for mains connection    Terminal block for motor    X2     FS101     CS 300FS  prewired           r 190    RE TI    OO OO OO OOO FATE 0000000000  20000000 220000  2020022000        EXT  TASTEN min G  SEH  EE  TUNA     0 e    a NA ne  ALIF jme UE E                 MFZ MFZOVITOR    Connection arrangement for limit switches   CS 300FS terminals X11  X10 and FS 101 terminals X03  X05     X11 CS300 FS             r X03 FS101   X05 FS101                             X10 CS300 FS                 safety  circuit     CLOSE  OPEN     limit switch OPEN     limit switch CLOSE     additional limit switch CLOSE     additional limit switch OPEN      Thermal protection motor   factory provided  prewired      em
3.   Potential free relay    EMERGENCY MODE  Potential free relay    FAULT  Potential free relay    INPUT  FIRE ALARM      24 VDC   50mA      Please take the connection of the door operators FT3 and FDF6 from the attachment                  e  MEZ MFZOVITOR    Terminal strip X06  potential free continuous contact as normally open contact   X06 FS101 Dip 2   OFF       Fire alarm contact 6  C_T   5      41 T   X10 FS101   24 VDC   max  50mA 3     21M   Im    Fire alarm contact       X10 FS101   24 VDC   max  50mA  1    relay K10 for fault indication                  Terminal strip X07           kia XO7 FS101 Potential free switching contact indicates the following faults   2 Rechargeable battery fault   mains power failure  switches if  the battery is defective or if the battery voltage is less than  19V     Terminal strip X08   relay K11 for emergency closing   X08 FS101  Potential free switching contact for emergency operation is  active  Switches for emergency closing     K11    Terminal strip X04     relay KO6 door drive command    X04 FS101      Potential free switching contact for CLOSE or OPEN  command depending on DIP switches 1 and 3      See 12 and 13 1 for wiring and function     Terminal strip X09     relay K12 SKS    TEE Potential free switching contact  signalize    K12   the state from the safety edge              MEZ MFZOVITOR    With Timer 1  the controls can delay the automatic closing of the door after a mains power failure by a  set period  When set to 0  the d
4.   Terminal block X4  for pneumatic safety edge device     DW   X4 CS 300FS                               Limit switch half open           only effective in down direction        e  MEZ MFZOVITOR    Accu    o       Circuit board FS 101          X01  X02  X03   X04   X05   X06   X07   X08   X09   X10    AKKU    Time 1  Time 2   303  Reset  Test  F200  ON    KO4  KO5  KOG  KO7  KO8  KO9  K10  K11  K12           MFZ MFZOVITOR    Power supply 230V   PE   Limit switch connections   Outputs for the auxiliary motor  brake  auxiliary relay  Activation of the CS 300FS circuit board   Fire alarm connection   Potential free output for fault indicator   Potential free output for fire alarm   Potential free output for closing edge device   Input  external 24 V   Terminal block for battery pack    Time controlled closing if mains power supply fails  Timing element for door seal function   DIP switches   Button     switch off buzzer   Button for testing emergency operation   3 15 A fuse for battery charger   button    Relay secondary motor   Relay engine brake   Relay OPEN   CLOSE command  Relay limit switch OPEN   Relay limit switch CLOSE   Relay Stop   Relay Function   Error   Relay Emergency mode   Relay Closing edge                   e  MEZ MFZOVITOR    DPswich       Door closes if a fault occurs    5 OFF Door remains open if a fault occurs    6 ON Door operator types HY      6 OFF Door operator types FT    When making changes to the DIP switch settings  the following procedure must be o
5.  ON during open time   MOD17  Brake remains ON in open time and   while changing direction  in SKS  brake falls   down    MOD18  Red lights are flashing in prewarning  RELAY 4 MOD19  SKS MOD 19 MOD19  PRESSURE ON  PS testing is active ONOFF OFF    SENSOR TEST OFF  PS testing is inactive  DELAY OPEN ON  Forewarning before opening ONOFF OFF    OFF  immediate opening  SELF LOCK MOD1  Automatic operation MOD1   MOD3 MOD1  MOD2  Manual operation for OPEN and CLOSE  MOD3  Manual operation for CLOSE  SUMI MOD1  PART OPEN button at terminal X4 9 10  MOD1MOD2 MOD1  MOD2  PART OPEN selector switch at terminal  X4  9 10   When the selector switch is closed  all OPEN  commands go to the before end switch OPEN  REVERSE MOD1  It does not take place a reversion  if the MOD1MOD2 MOD1  additional limit switch is too operated   MOD2  It takes place a reversion  even if the  additional limit switch is too operated     RELAY 3 MOD1     MOD18 MOD1                   e  MEZ MFZOVITOR    The FS345 control unit has protection against deep discharge of the battery and can carry out regular  tests to check the condition of the battery     If  after being put into operation  the controls are operated for a longer period without the external  power supply  the control unit switches itself off after a specified length of time to prevent deep  discharge of the rechargeable battery  The length of time depends on the type of door operator and  thus on the external devices connected     DIP 1 ON switches off 
6.  must be fitted with appropriate suppressor elements  recovery  diodes  varistors  RC circuits     Potential free closed circuit contact  min  10mA  max  230V AC   4A   Once contacts have been used for power circuits  they can no longer  be used for extra low current circuits    Emergency operation output relay If inductive loads are connected  e g  further relays or brakes   these  must be fitted with appropriate suppressor elements  recovery  diodes  varistors  RC circuits     Potential free closed circuit contact  min  10mA  max  230V AC   16A    Once contacts have been used for power circuits  they can no longer  be used for extra low current circuits     Mounting Vertical mounting on the wall  minimum height above floor   1m  Housing  wxhxd 300mm x 600mm x 130 mm   Operating temperature  5  C      556   storage temperature  200      85T    Protection categor IP 54    Fuse provided on site Max  10 A K characteristic  Weight 10 5 Kg       
7. 1  Safety of machinery   Basic concepts  general principles for design   Part 1  Basic  terminology  methodology     Low voltage    EN 60335 1  Household and similar electrical appliances   Safety     EN 60335 2 103  Particular requirements for drives for gates  doors and windows     Professional association regulations D    BGR 232  Directive for Power driven Windows  Doors and Gates               MEZ MFZOVITOR    Product description  The FS345 controls can be used in connection with fire proof door drives     The FS345 controls consist of an CS300 door control unit  an FS101 auxiliary circuit board and a rechargeable  battery for the solenoid valves  magnetic clutch  DC motor and for 24V engine brakes     In the case of fire or power cuts  the emergency rechargeable battery provides the energy for the secondary motor  for closing the gate or for the engine brake for holding the gate     The fire mode is triggered by a continuous command in the fire alarm contact or is time activated if the mains  power supply fails  In the case of fire  the door closes with the closing edge system deactivated  or  optionally  with  the closing edge activated     Different models  The following models of the FS345 controls can be supplied     FS345 controls for dead man operation    F345 controls for automatic operation    FS345 controls for automatic operation with the closing edge system activated in the case of fire    The following housing models are available     Housing with OPEN   STO
8. 1 1    TIAS    01            e  _ D010 Bod O             De   rs          The FS345 control unit is equipped with a row of LEDs that indicate the current operating status of the              MFZOVITOR    Code   Color   Description    Errordiagnosis    yellow LED Safety circuit LED ON OK   input X03 1 2  LED OFF   Missing mains supply   ACCU voltage  Safety circuit of the operator interrupted  pep emar LES amean   input X03 3 4 5  LED OFF   Limit switch OPEN confirmed  pe frm  agua ga  eos NA   input X03 6  7 8  LED OFF   Limit switch CLOSED confirmed  ep f  e  Eo  Re   output X04 1 2  LED OFF   Auxiliary motor 24V DC is not active  pep fete ia  makan   output X04 3 4  LED OFF   Engine brake is switched off  pe er LED Drive command LED ON Drive command open close at CS300FS active  open close LED OFF   Drive command open close at CS300FS is not   output X04  5 6  active  D07 yellow LED Limit switch OPEN LED ON Limit switch OPEN not confirmed   output X05 1 2  LED OFF     Limit switch OPEN confirmed    Emergency operation is active   output X05 3 4  LED OFF   Limit switch CLOSED confirmed    yellow LED Stop circuit LED ON OK   output X05 5 6  LED OFF   Missing mains supply   rechargeable battery  voltage   Safety circuit on drive unit interrupted    Emergency operation is active          yellow LED AS130 OPEN LED ON Door is moving towards OPEN in 400V operation   input X05 7 8  LED OFF   Door is not moving towards OPEN in 400V  operation  yellow LED AS130 CLOSE LED ON Door is m
9. MFZ Antriebe GmbH  amp  Co  KG  Neue M  hle 4    orton OY MEZOVITOR    Operating Instructions for FS 345 with FS 101 and CS300 FS       GB        e  MEZ MFZOVITOR    To enable fault free operation to be guaranteed  it is imperative that the  rechargeable battery be replaced after every two years of operation  If this  maintenance instruction is disregarded  the functional safety of the system  and thus also the safety of buildings and persons cannot be guaranteed     To ensure that the system always functions consistently  the fire alarm  function must be checked once every four weeks  In order to check at the  same time that the rechargeable battery also functions correctly  the controls  must be disconnected from the mains  In this way  the emergency function  can be checked to ensure that the door is closed automatically by the auxiliary  motor     Emergency operation is not possible if there is a fault in the safety circuit of  the door operator     To avoid a deep discharge of the rechargeable battery  the battery should not    be connected to the FS101 unit until the system is put into operation for the       first time     If deep discharge occurs  the battery cannot be recharged again and must be  replaced immediately                                      Table of contents   Key to symbols   General safety advice   Overview of product   Start up the emergency operation system  Start up     gate operation system   Connection examples   Products drawing  emergency operat
10. P   CLOSE buttons    Housing with ON   OFF key switch    Housing with mains switch    Housing with emergency OFF switch    The operating instructions describe the connection options and models of the FS345 controls            MEZOVITOR    Accumulator       fo o4  om    TIME  ol     TL loc    FS 101       100 0  o       BO ds     a      2 ngogog  el  cho 00 oe oo T me O    BO 2000000000                                                                                                                                                                   O U UV H BI B2 Mle 7 6 5 4 3 2 1 8 7 6 5 4 3 2   O  O O O TO  1  ololo ab ofofofofofofofo OIOIOIOIOIOIOIO  Ud DO a A  a 13 1 3 5 1 3 5 13 A EC O O                                                                                        O  0    o  O                   CS 300FS A EET O  O                                                                                                                          a Fl hoon Do    x9  F X7 X6    i    EXT  TASTEN SL   SCH  EXT  FUNK  o de     Le    x ie Q  g O BEFEHLSGERATE H4 FOTOZELLE SKS TOP    SCHLOSS  STOP   AUF JIMPULS  2U                                                                                         FOTO   8K2 7 OSE  HALBAUT  FUNK                  OIO    OIOIOIOOIOlIOlO                                                                               ojo OIOIOIOIOIOIOIOIOIO OIO                      O ua O  2304 7 400 AKKU X3 1 2 3 4 5 6 7 8 9 10 X44 2 3 4 5 6 7 8 9 10                    
11. after 8 hours without mains supply voltage  DIP 1 OFF Switches off after 48 hours without mains supply voltage    The buzzer sounds continuously for 60 seconds to signal that the battery  and therefore also the  control unit  has been switched off     If the timer 1 on Zero stands  no drive in the case of power failure  in dependence of the DIP switch 5  the gate is controlled closed or left alternatively open  Controlled keeping open is only with DIP 1 OFF  possible     DIP 5 ON Gate closes after the audio signal  accumulator control switches off  DIP 5 OFF Gate remains open  for accumulator control switches off       The controls can only be switched on again if the external voltage supply is reconnected     For FT types of operator  DIP 1 ON   if the mains supply has been interrupted for a  period of 8 hours or longer  the battery is charged for 30 minutes as soon as the mains    A voltage is switched back on  The door controls cannot operate during this charging  period     This charging status is indicated via the recharge LED and can be interrupted by  pressing the RESET button        flashing in  change                     e  MEZ MFZOVITOR    The FS345 control unit is able to test the condition of the battery automatically  In normal operation the  battery is disconnected from the controls once every 60 minutes and the battery voltage is checked     If the battery voltage falls below a specified value  this is recognized as a fault  which is then indicated  via the fau
12. bserved   1  Switch off the mains voltage   Switch off the rechargeable battery voltage   Change the DIP switch position as required   Switch on the rechargeable battery voltage   Switch on the mains voltage       QUE PS      only with version HY    The FS345 controls are designed for use with different types of door operator     DIP 1 ON and DIP 6 OFF  1  FT door operators with 24V DC engine brake   In emergency mode  the door closes under its own weight     The weight of the door is held by the engine brake  which is still supplied with electricity   The power supply comes from the mains adapter on the FS101 circuit board  if the mains  power is interrupted  power is supplied from the rechargeable battery      DIP 6 ON is needed for the version HY                                                                             ON OFF  DIP 1 OFF  1  FD  FDF  FTA  FDS  door operators with 24V DC secondary motor and 24V DC  engine brake  FDF 5   In emergency mode  the door closes with the 24V DC secondary  motor    The power supply comes from the mains adapter on the FS101 circuit board  if the mains  power is interrupted  power is supplied from the rechargeable battery                                                                                                                 X09  X08  X07  X06  X10  X04                    Potential free relay  OPEN CLOSE command    d Engine brake at FT  FDF door operators       M  secondary motor            MEZ MFZOVITOR    CESD  closing edge 
13. controls  this function is time controlled and is set using  TIMER 2  A value of 0 to 5 seconds can be selected     Prerequisites     Door operator type FT  DIP 1 ON       The system has been set in operation     and the limit switches have been set     Settings    OPEN and CLOSE limit switches are set for normal door operation    Set Timer 2 to the mid range value of 2 5 seconds    Drive the door to the OPEN end position    Switch off the mains voltage supply and press the TEST button    The door runs to the CLOSED end position in emergency operation mode     6  The dooris then driven beyond the CLOSE limit switch for 2 5 seconds  Only then  is power supplied to the engine brake again and the door is held in position     7  Repeat steps 2 to 6 entering different values for Timer 2 until optimum results are achieved   8  The CLOSE safety limit switch must be set accordingly     So kag           MFZ MFZOVITOR    To ensure that the system functions properly at all times  it is necessary to check the fire  alarm function at intervals of four weeks  In order to check at the same time that the    rechargeable battery functions properly  the controls must be switched off when carrying  out this test  This is the only way to demonstrate that the emergency function is operational  and that the door closes automatically via the auxiliary motor        Procedure   1  Drive the door to the OPEN end position   2  Switch off the mains voltage power supply   3  Press the TEST button  emerge
14. ct free of potential        Page 34 of 36     FS 345 FS101 CS300FS   Rev  01              MFZ MFZOVITOR             2 2  Limit switch OPEN green  3 3  Safety limit switch OPEN red  4 4  Safety limit switch CLOSED red  5 5  Limit switch CLOSED white  6 6  Additional limit switch CLOSED white       1  Drive the gate to wished CLOSED position   2  Set the control cam 5  white  the way that the limit switch is operated     3  Tighten the fixing screw A              4  Fine adjustment is done with the screw B   5  Drive the gate to wished OPEN position    6  Set the control cam 2  green  the way that the limit switch is operated   7  Tighten the fixing screw A     8  The safety limit switches 3 and 4  red  must be set the way that they react directly after passing    the control limit switch   9  After the operation test  control the fixing screw     10  The additional limit switches 1 and 6 have change over contact free of potential            MEZ MFZOVITOR    Supply voltage 3  400VAC  50 Hz      10  STANDARD  3  230VAC  50 Hz      10  SPECIAL VERSION    Further voltages on request  Power input Max  2 2 KW  Maximum power consumption of the CS300FS controls themselves    250mA  secondary  Maximum power consumption of the FS101 controls themselves      200mA  secondary    Motor data Max 2 2 KW   3 2 A   Controls voltage 24 VDC   Batteries Maintenance free batteries with VdS certification   Fault output relay lf inductive loads are connected  e g  further relays or brakes   these   
15. ction  ADVANCE The traffic light flashes before the door starts to 0   120 Seconds 0   OFF  WARNING TIME move downwards  The programmed forewarning   time is only active if the open time  gt  0 or if in    radio impulse operating mode    TURNAROUND Standing time at every change of direction 0 1   2 0 Seconds 0 3 Seconds   TIME  in 1 10 Seconds    MOD1 3 MOD1  in non operative state OFF MOD1 MOD1   RESTING MOD2  in non operative state ON MOD2   QUICK CLOSE ON  The open time is cut short after the ON OFF  photoelectric barrier has been passed  door OFF    closes immediately   OFF  The open time continues as usual  RELAY 1 First 3 Relays can be allocated to a relay mode of  MOD1     MOD18 MOD6   1 18  MOD1  Red lights while the gate moves and  flashing in prewarning mode  MOD2  Red lights are flashing while the gate  moves and flashing in prewarning mode  MODS  Red lights while the gate moves and in  prewarning  The parameter M1 3 non operative state takes   effect at these 3 MOD              MEZ MFZOVITOR    Function Description setting options Factory setting  RELAY 2 MOD4  Impulse at OPEN order MOD1     MOD18 MOD7   MODS  Error message   MOD6  OPEN end position   MOD7  CLOSE end position   MOD8  Final position OPEN denied   MODO9  Final position CLOSED denied   MOD10  Before end position OPEN   MOD11  Before end position CLOSE   MOD12  From before CLOSE position to CLOSE   position   MOD13  Magnetic locking function   MOD14  Brake   MOD15  Brake negated   MOD16  Brake remains
16. e to a fault    3 flashes    Color Description Error diagnosis  LEDON OK  LED          green D LED   connecting block is interrupted  9 OFF   connecting block is defective  Fault   error message Cause Rectification    System does not respond   No voltage supply   Gheck the voltage supply of the  drive and the controls     Check the rotating field and  establish clockwise rotating field if  necessary     check terminal X11 connection      check limit switch connection    Door travels to the CLOSE   Rotating field is connected  end position when the OPEN wrongly   button is pressed   ERROR END POSITION   The limit switches OPEN    and CLOSE are both open              ERROR RUN TIME    ERROR CESD    ERROR PRESSURE  SENSOR TESTING    but once have to be closed     The programmed running  time has been exceeded     The safety edge protection  is faulty     Safety edge protection was  triggered     The PS switch is not  activated at the CLOSE end  position      check limit switch adjustment     check the path of the door     Re program the running time     check the safety edge protection  and the spiral cable     Remove obstruction from path  of door     check the PS switch  spiral  cable and profile     check the setting for the CLOSE  end position         e  MEZ MFZOVITOR                                   Legend   A  Operating mode   diagnostic info  B  Parameters   diagnostic info  C    button  In      TI   D      button  RUHESTELLUNG F E  P button    F  value   status    G  va
17. ergency operation  opener     factory provided  prewired if delivered with drive        safety limit switch CLOSE     safety limit switch OPEN    The limit switches  excluding the additional limit switch  are analyzed by the FS101 circuit board and  the values are passed on to the CS300FS circuit board     The allocation of terminal X11  limit switch  was changed in relation to the allocation of  terminal of CS300FS  This must be considered during back fitting           e  MEZ MFZOVITOR    Command and safety devices can be connected via terminals X3 and X4          X3 CS 300FS X6 CS 300FS      1   terminal block for    EE on 2 internal on off switch    IMPULSE button X7 CS 300FS   terminal block for    OPEN butt internal 3 button input unit  utton    l STOP    STOP button   OPEN  Sll   emergency off  slack rope switch  5 LOSE    wicket door contact  draw in protection 6          OPEN   STOP   CLOSE button OPEN   STOP   CLOSE button     for solution with 6 leads   for solution with 4 leads          S      Cc    c 6  2 g E 2 E    a a a 2 2 5  E A JJ E A   l  0 O O 0 O O  Key switch OPEN   CLOSE Impulse button     sequence button        AUF  ZU    IMPULSE  button              0  MEZOVITOR    Terminal block X4  8 2 kOhm safety edge device   X4 CS 300FS             Photocell drive through barrier        Safety edgedevice 8 2 kOhm                    Limit switch half open       Terminal block X4  for opto electronic safety edge device     X4 CS 300FS                                
18. ion   Key to FS101   DIP switch functions   Types of door operator   Connection options FS 101   Adjustment options TIMER 1   Automatic operation with active CESD in emergency mode  Emergency closing with door operator   Door sealing function   Checking the rechargeable battery and emergency operation  Integrated buzzer   Fault indicator and diagnostic LED   Display function CS 300 FS   Protective functions and charging the battery  Special interconnecting   Adjustment of limit switch   Technical data    OONO OR O Ny      Danger of personal injury   The safety instructions must be observed     Warning  Danger to property   The safety instructions must be observed     Information  I   Indicates a reference to other sources of information    4    Guarantee    instructions are adhered to     Use fort he intended purpose        e  MEZ MFZOVITOR    The function and safety of the equipment is only guaranteed if the warnings and safety advice in these operating    The FS 345 controls are intended exclusively for controlling door systems with mechanical limit switches                     MEZ MFZOVITOR    Target group   Only qualified and trained electricians may connect  program and service the controls   Qualified and skilled electricians must      have knowledge of the general and specific safety and accident prevention regulations     have knowledge of the relevant electrical regulations      be trained in the use and care of appropriate safety equipment and clothing      be capab
19. le of recognizing the dangers associated with electricity     Instructions for installation and connection      Before commencing electrical works  the system must be disconnected from the mains electricity supply and  from the emergency rechargeable battery  Measures must be taken to ensure that the electricity supply remains  disconnected for the duration of the works       Local safety regulations must be observed     Mains cables must be laid separately from control cables     Regulations and bases for testing  For connecting  programming and servicing  the following regulations must be observed  the list is not exhaustive      Construction product standards    EN 12453  Safety in use of power operated doors   Requirements       EN 12978  Safety devices for power operated doors and gates   Requirements and test methods     Electromagnetic compatibility  EMC       EN 50014 1  Emission  household appliances      EN 61000 3 2  Disturbances in supply systems   harmonic currents      EN 61000 3 3  Disturbances in supply systems   voltage fluctuations      EN 61000 6 2  Electromagnetic compatibility  EMC    Part 6 2  Generic standards   Immunity for  industrial environments      EN 61000 6 3  Electromagnetic compatibility  EMC    Part 6 3  Generic standards   Emission    standard for residential  commercial and light industrial environments     Machinery guidelines    EN 60204 1  Safety of machinery  electrical equipment of machines  Part 1  General requirements       EN 12100 
20. lt relay  the buzzer and the diagnostic LED  It could be that proper operation in emergency  mode is then no longer possible     DIP switch 5 can be set to specify whether the door closes or stays open in this case     DIP 5 ON The door closes  the battery switches off  DIP 5 OFF The door stays open  the battery switches off       Verbindung CS300FS   FS101 DIP 5 ON  ON OFF       CS 300FS FS101                                                                Advice on recharging maintenance free lead acid batteries    Before longer periods of non usage  two options     Disconnect your battery from the charger and store it fully charged     If the periods of non usage last for more than three months  charge the battery for  at least 36 hours       Itis also possible to continue to charge your battery for an unlimited period  trickle  charging  with the charger switched on  It is advisable to store the battery in a cool room     High temperatures   Charging the battery at ambient temperatures greater than 30  C is not recommended   Your charger is set in the factory to a charging voltage that is designed for an ambient  temperature of 20  C     Low temperatures  Charging the battery at temperatures lower than 10  C is not recommended  The available  Capacity is reduced at lower temperatures     Deep discharge  Please avoid deep discharge of the battery  Should this occur  recharge the battery as soon  as possible for a period of 24 hours         e  MEZ MFZOVITOR    Battery charge
21. lue   status  H  jumper    The control has four modes of operation with the LCD monitor  When the jumper H is pulled  the      button  the     button and the  P  button have no function  The display still functions     Operating mode 1  AUTOMATIC  In the AUTOMATIC operating mode the door system is operated   Display    displays the function being carried out     displays any error massages    Advice  If the    self locking    parameter is set to MOD2 or MODS in the input menu  the display changes  from AUTOMATIC to MANUAL OPERATION  The buttons   and     are without function     Operating mode 2  ADJUSTMENT    In the ADJUSTMENT mode  the OPEN CLOSED end position settings in dead man mode are adjusted  with using the   and   buttons     Display     displays the operating mode  Advise  The external buttons are without function     Operating mode 3  INPUT  In the INPUT operating mode  the values of various parameters can be altered   Display    displays the selected parameter     displays the programmed value status    Operating mode 4  DIAGNOSIS   In the DIAGNOSIS operating mode  door specific checks can be queried   Display    displays the check     displays the status           MEZOVITOR    AUTOMATIC uU  RESTING    Push P button  gt  1 sec     ADJUSTMENT XXXX   Push   button  Position MANUAL ADJUSTMENT Save door position   RESTING DOOR OPEN OPEN Push P and   button  gt  1 sec       Push   button  Position MANUAL ADJUSTMENT Save door position   DOOR CLOSED DOWN Push P and   bu
22. ncy operation  Should commence after a delay of 2 seconds        Check   After pressing the TEST button    mb       Battery test has started     LED display       flashing on off    2  The integrated buzzer sounds  M    3  After 2 seconds  the door moves to the CLOSED M  end position     4  The buzzer stops buzzing  M      5    LED display       6  The buzzer sounds once  M on Flashes for    5 sec     7  The test is complete  M                   e  MFZ MFZOVITOR    The FS345 control unit has an integrated buzzer that gives an acoustic signal to indicate emergency  operation and the condition of the rechargeable battery     The buzzer sounds with a frequency of 1 Hz during the closing phase in  emergency mode   The buzzer stops sounding when the door is in the CLOSED end position     If a defective battery is detected during operation or during a test  the buzzer  sounds with a frequency of 3 Hz        CLOSED end position  The rechargeable battery must be replaced     Buzzer    1 note sounds at intervals 0f 5 seconds No mains voltage    4 short notes Warning before emergency closin    The acoustic warning signal can be switched off by pressing the RESET button when the door is in the    1 note sounds at intervals of 1 2 second Rechargeable battery is defective           1 note sounds at intervals of a second Emergency closin           system and signal any faults that may occur  The following table gives an overview of the different  faults and status conditions        FS101 P
23. nfirmed   ON  not confirmed  P E BARRIER Photoelectric drive through barrier ON  closed   OFF  interrupted  fault   STOP CIRCUIT    Stop button of controls ON  closed     Stop button of drive OFF  interrupted  fault    BES OPEN Additional limit switch OPEN OFF  confirmed   ON  not confirmed  BES CLOSE Additional limit switch CLOSE OFF  confirmed    ON  not confirmed  CYCLE Door cycle counter Displays the door cycles         e  MFZ MFZOVITOR                Display Description    AUTOMATIC The door is driven to the OPEN end position   OPEN   AUTOMATIC The door is driven to the CLOSED end position   CLOSE   AUTOMATIC The door stands between the end position   RESTING   AUTOMATIC O The door stands at the OPEN end position   RESTING   AUTOMATIC O The door stands at the position PART OPEN   before end position    up   RESTING   AUTOMATIC U The door stands at the CLOSED position   RESTING   AUTOMATIC u The door stands at the position PART CLOSED     before end position     RESTING down                          Function Description Setting options Factory setting  DEUTSCH Select the menu language DEUTSCH  ENGLISH  DEUTSCH  FRANCAIS  ESPANOL   NEDERLANDS  POLSKI     CESKY  RUNNING TIME Monitoring the max  running tine for an open and 1     250 Seconds 60 Seconds  close movement  OPEN TIME After the door has opened  it runs in the CLOSE 0     600 Seconds 0   auto drive OFF    direction again after the set time has elapsed    Open time  gt  0   impulse functions only work in   OPEN dire
24. oor does not close automatically in the event of a mains failure    If the timer is set so 0 and the mains supply is cut off for a longer period  the deep discharge protection  system of the controls comes into play  See 17 1            No automatic closing in the event of mains failure Timer 1    Inthe event of mains failure  door closes after 5 seconds     Inthe event of mains failure  door closes after 15 seconds     Inthe event of mains failure  door closes after 30 seconds     Inthe event of mains failure  door closes after 1 minute    In the event of mains failure  door closes after 2 minutes      Inthe event of mains failure  door closes after 5 minutes      Inthe event of mains failure  door closes after 15 minutes     Inthe event of mains failure  door closes after 30 minutes     Inthe event of mains failure  door closes after 60 minutes        O ON OOF    D   O  1               lt is possible to monitoring the emergency closing procedure via an electrical contact bar  The door  continues to close if the bar is no longer activated and if a delay period of 2 seconds has elapsed  No  reversing takes place  The closing edge safety device  CESD  is checked when it reaches the upper  end position  If a fault is detected  emergency operation takes place without evaluation of the CESD     Prerequisites     Connection made between CS300Fs and FS101  see drawing       Adjust relay mode 19 for relay 4  factory setting     FS101 DIP switch 4 ON  disconnect main power and batter
25. oving towards CLOSED in 400V   input X05 9  10  LED OFF   operation  Door is not moving towards CLOSED in 400V  operation    yellow       LED Fire detector LED ON Fire detector is closed   input X06 1 2  LED OFF   Fire detector is open  yellow LED Operation   fault LED ON operation   no fault   output X07 3 4  LED OFF   Battery fault  mains  yellow LED Emergency operation   LED ON Emergency operation is active   output X08 1 2  LED OFF Emergency operation is not active  yellow LED CESD LED ON CESD is OK   output X09 1 2  LED OFF   CESD is interrupted  green LED charge maintenance LED ON ACCU is charged  maintenance phase  LED OFF   ACCU is charging  yellow LED charge status LED ON Charging period  LED OFF Not charging period  ACCU is charged    red LED ACCU fault LED ON ACCU defective  CHANGE ACCU    LED OFF   ACCU OK    D017    D018                     e  MEZ MFZOVITOR    Code D 019  color red    Diagnostic LED Fault Action     red  ee  1 flash Battery fault Rechargeable battery is    defective  replace  2 flashes Mains power failure Battery charger defective   FS101 fuse F2 defective    Command received from fire alarm or from  T1    the door should close   4 flashes Door has been closed by the fire alarm or    by  5 flashes Safety circuit input X03 1 2 has been Check the safety circuit of the    interrupted door operator  6 flashes HY Leak  only version FS345 HY   Check the hydraulic system    7 flashes CESD defective at OPEN end position  8 flashes Door has been closed du
26. ower rela  motor p y    secondary motor         Lomme           CS 300FS       Erklarung    K1  contactor CLOSED   K2  contacto OPEN   M1  motor   T1  Transformer 230V   X1  terminal strip mains connection    X2     terminal strip motor           MFZ MFZOVITOR    230V   50Hz 3 N PE    o  ejej    Connection      gt      gt      gt     Connect the control to the mains    Connect the control to the motor    Short before the corresponding screw terminals   groukps of cables should be make safe by means  of straps     9  MFZOVITOR    GB 22 Adjustment of limit switch FDF   FTA   FDS    1 2 3 4 5 6                            Tae nee   2  WAY OA Ie     th    3  4  5  6  FDF FTA   FDS  1  Additional limit switch OPEN green  2  Limit switch OPEN green  3  Safety limit switch OPEN red  4  Safety limit switch CLOSED red  5  Limit switch CLOSED white  6  Additional limit switch CLOSED white  1  Drive the gate to wished CLOSED position   2  Set the control cam 5  white  the way that the limit switch is operated   3  Tighten the fixing screw A   4  Fine adjustment is done with the screw B   5  Drive the gate to wished OPEN position   6  Set the control cam 2  green  the way that the limit switch is operated   7  Tighten the fixing screw A   8  The safety limit switches 3 and 4  red  must be set the way that they react directly after passing    the control limit switch   9  After the operation test  control the fixing screw     10  The additional limit switches 1 and 6 have change over conta
27. r    AN Caution     Hazards can arise when operating battery chargers       Danger of explosion  due to the build up of explosive gases when  charging the lead acid rechargeable battery       Danger of fire and short circuiting  due to electric shocks in moist  conditions     To prevent hazards arising   e Ensure that there is sufficient ventilation   e Avoid open lights and fire   e Only use the charger in dry rooms   e Protect the charger against moisture     Safety advice    The battery charger of the FS101 circuit board is only suitable for  charging maintenance free lead acid batteries  Only qualified persons  may open the charger and it must never be operated when opened   The charger may only be used in the FS345 control unit  The  guarantee is no longer valid if the charger is damaged as a result of  being opened incorrectly  Before putting the charger into operation   ensure that there is sufficient ventilation  The charger may only be  used in closed rooms and must not be subjected to moist conditions     Any alterations made to the charger shall render the equipment  approval invalid                0  MEZOVITOR    DJ       4  O  OOo 00    0 0 OO OO    Or 10 000000000  Zooccococcloooocooccoocococcocococol      2 3 4 5 6 8 1 2 3 4 5 6 1 2 3 4 5 6 7 8 3 10    1  gt        CS 300 FS Additive power  supply unit    24V DC    K14    K13    engine brake 24V Dc        NN               MEZOVITOR    Accumulator FDF  6    Ju    EE EE  aoe 220000 22200020006       secondary    
28. tton  gt  1 sec   Push   and     gt  2 sec  INPUT Scroll up through menu   GERMAN   gt 2Sec    Push P button  gt  1 sec     Scroll down through menu     INPUT   RUNNING TIME 6   gt 2 Sec    INPUT   TIME OPEN 0 Select value  P  gt  1 Sec   INPUT   FOREWARNING 0 Increase value       INPUT    0  INPUT Decrease value     AROUND TIME 3 Save value  P  gt  1 Sec     MOD1 3 RESTING MODI Return to    INPUT    QUICK CLOSE    INPUT  RELAY 1    INPUT  RELAY 3  INPUT  RELAY 4    INPUT    and    gt  1 Sec   OFF    MOD6    MOD7    MOD1    MOD19    INPUT  SENSOR TEST OFF  INPUT  DELAY OPEN OFF    INPUT    SELF LOCK    INPUT  SU WI  INPUT    REVERSE    INPUT  RELAY 2    MOD1    MOD1    MOD1               MEZ MFZOVITOR            Push P button  gt  1 sec     Scroll up through menu   ES DOWN    gt  2 Sec   Scroll down through menu   PART OPEN    2 Sec       CESD dE Return to    STIMER   Only inquiry possible  STOP CIRCUIT  BES CLOSE       Push P button  gt  1 sec                        Displa Meanin Status  ES OPEN OPEN end position OFF  confirmed    ON  not confirmed  ES CLOSE CLOSE end position OFF  confirmed   ON  not confirmed  OPEN BUTTON OPEN button OFF  confirmed   ON  not confirmed  PART OPEN PART OPEN button  X4   9   10  OFF  confirmed   ON  not confirmed  CLOSE CLOSE button OFF  confirmed  BUTTON ON  not confirmed  CESD Safety edge protection ON  System is closed   OFF  System is interrupted  fault   IMPULS Impulse button OFF  confirmed   ON  not confirmed  TIMER Weekly timer OFF  co
29. y voltage     CESD has to be connect to terminal X 4    Connection CS 300FS   FS101 DIP 4 ON    ON OFF  FS101 CS 300FS  ACCU       NO  iN   lt   U  O    Mw 0 0                         af   k                                   e  MEZ MFZOVITOR    lt is possible for the door to be closed using the door operator when the fire alarm is activated     Prerequisites  Connection between CS 300FS   FS101    CS300FS X3 9 10 are connected to FS101 X04 5 6 CS 300 FS ES101    DIP switch 3 is set to ON X3 X04     Disconnect main power and battery voltage     In this case  if the fire alarm is activated and the mains voltage is  available  the FS101 circuit board sends a DOWN impulse to the    CS300FS circuit board via X06     X3 connection    The door is the driven to the CLOSED end position in impulse mode   The safety elements connected to the system are active    Once the CLOSED end position has been reached  the door cannot be  opened again  If the CESD is activated during the closing phase  the  door reverses and stops at the OPEN end position  After 30 seconds a  further DOWN impulse is sent  If the CESD interrupts the closing  phase again  the process is repeated 3 times in total  If the CLOSED  end position has not been reached after 120 seconds  the door is then  closed via emergency operation mode                                To ensure that the sections of the door close together tightly in emergency  mode  the door must be driven beyond the CLOSE limit switch    With the FS345 
    