User Manual NC9100 NC9200 NC9300
Contents
1. Port 1 2 F lt V rde Beskrivning p 10001 10002 Local TCP port a 0 0 0 0 Remote IP address r 10001 10002 Remote TCP port b 9600 Baud rate t 10 Receive timeout bits d 10 RS485 timeout ms 5 00 Start character E 00 End character op 0 Serial Option Enable Parity 0 Serial Option Enable Odd od 1 Serial Option Enable 8 Databits os 0 Serial Option Enable 2 Stopbits oc 0 Serial Option Enable Flow Control oa 0 Serial Option Enable AT Command oh 0 Serial Option Enable ATH Command ot 0 Serial Option Enable Close via DTR or 1 Serial Option Enable Remote connect ol 1 Serial Option Enable Local connect ok 0 Serial Option Enable Break signal ob 0 Serial Option Enable RS485 om 0 Serial Option Enable RS485 Multi point of 0 Serial Option Enable RS485 Half Duplex 0 Serial Option Enable Termination Rcv 02 0 Serial Option Enable Termination Snd 0 Serial Protocol Enable Text code AT V1 cx 0 Serial Protocol Enable Extended code AT X1 ca 0 Serial Protocol Enable Code AT CONNECT 1200 cc 0 Serial Protocol Enable Control header ch 0 Serial Protocol Enable Handshaking ce 0 Serial Protocol Enable Exomatic cn 0 Serial Protocol Enable Nova Tune 22 NET CONTROLLER E User Manual NET CONTROLLER 15 Reset button R 16 LED function P H A T R TRANSMIT DATA 2 Yellow blinking Serial port 2 Transmit RECEIVE DATA 2 Yellow blinking Serial port 2 Receive 17 Power PW Terminal T4 c
2. Enable Encryption 64 Bits encryption of the data MAIN o e 1 Main Option Enable Permission Enable permission control for extern connection via IP Control against Remote IP Adress MAIN o p 1 Main Option Enable Web Enable start of Web Server MAIN gt 0 w 1 16 NET CONTROLLER E User Manual NET CONTROLLER Select port 1 menu Select port 1 menu MAIN gt 1 PORT 1 gt Select port 2 menu Select port 2 menu MAIN gt 2 PORT 2 gt Submenu for port 1 and port 2 Show menu Show a list of commands for port 1 and port 2 PORT 1 gt Port menu p nnnnn Local TCP port a nnn nnn nnn nnn Remote IP address rnnnnn Remote TCP port b nnnnn Baud rate snn Start character enn End character t nnn Serial recieve timeout ms d nnn RS485 timeout ms Enable Parity Serial option o 0 1 Enable Odd parity o d 1 Enable 8 Databits 08 Enable 2 Stopbits oc l Enable Flow Control o 1 Enable AT commands o h 1 Enable ATH commands ot l Enable Close via DTR or 1 Enable Remote connect o 1 1 Enable Local connect o k 1 Enable Break signal o b 1 Enable RS485 o m 1 Enable Multipoint f 1 Enable Half duplex ox 1 Enable Termination 120 ohm 0 z 1 Enable Termination Snd 120 ohm c v Enable Text code AT V1 c x Enable Extended code AT X1 ca l Enable Code AT CONNECT 1200 1 Enable Control header c h 1 Enable Handshaking 1 Enable Exomatic c n 1 Enable Nova tune Back Return to main menu from port 1 or por
3. Port 2 3 TCP c nnn Connect timeout sec v nnn Activity timeout milisec 7 Restore to default values 8 Store to flash memory r Reset b Show statistics d Start download x Exit 1 Select port 1 menu 2 Select port 2 menu ou l Enable UDP Main option 14 NET CONTROLLER E User Manual NET CONTROLLER oe l Enable Encryption o p 1 Enable Permission o w 1 Enable Web Restore to default value Restore the parameters to default values MAIN gt z Warning Restore configuration to Flash Confirm with y MAIN gt y Store to Flash Exiting Configuration Store to flash memory Store the changes to the Flash memory MAIN s Warning Store to Flash Confirm with y MAIN y Store to Flash Exiting Configuration Show statistic Show statistics for the network MAIN gt b Received packets 10 Transmitted packets 10 Droped packets 0 Error packets 0 Port 1 Closed Port 2 Closed Start download Set Net Controller into waiting for download of new software Firmware Start download from NCsetup with selected file MAIN d Start Download Exit Finish configuration mode and return to data mode MAIN gt x Exit Configuration Enable service flag Enable service functions make it possible to change protected parameters 1 Ethernet MAC address Show Ethernet MAC address The address is unique for each Net Controller The address is printed on the label outside the Net Controller Serial number S
4. if manual or automatic IP setting shall be used Automatic IP setting is set as default in Net Controller IP address is 0 0 0 0 If manual IT setting ask for the IP settings from the network administrator such as IP address netmask and deafult gateway On connection check the LED P Power green is on power and started LED A Active Link yellow is on valid link for the network LED H High speed green is on if 100 Mbps link On automatic IP setting the network have a DHCP server to assign the Net Controller the MAC address is factory labelled on Net Controller Manuel IP settings is managed over the network with Web browser Telnet or via the serial port with Terminal utility software NCsetup Terminal Connect an Terminal PC to serial port 51 and start the NCsetup or a terminal program 1 Start the configuration by pressing the button R Reset long press The following text shows Configuration mode Net Controller NC200 STD 01 00 Enter password gt 3 Enter the password with command gt j control 4 The following text shows Configuration open MAIN gt 5 Enter the IP address with a command MAIN gt a 192 168 0 1 6 Store the changes to Flash memory with s command MAIN s 7 following text shows MAIN gt Warning Store Configuration to Flash Confirm with y 8 Confirm with y MAIN y 9 The following text shows to Flash Exiting Configuration Net Controller has assigne
5. 1 gt c v 1 Protocol Enable Extended code AT X0 1 Sets the default value for AT command Extension response codes 0 X0 basics 1 X1 X2 X3 X4 extended codes PORT 1 c 1 Protocol Enable Code AT CONNECT 1200 Sets the default value for response code 0 Standard 1 CONNECT 1200 response code PORT 1 gt c 1 Protocol Enable Control header Enable protocol header PORT 1 gt c c 1 Protocol Enable Handshaking Enable handshaking using signals RTS and CTS PORT 1 c h 1 Protocol Enable Exomatic Enable Exomatic filter for serial port PORT 1 gt c e 1 Protocol Enable Nova tune Enable Nova tune protocol for serial port PORT 1 c n 1 20 NET e CONTROLLER User Manual E NET CONTROLLER 14 Default value After clear the parameter has following values Main F lt V rde Beskrivning e 00 02 B8 00 00 01 Ethernet MAC address i NC910001 Identity typ mac p Control Password a 0 0 0 0 Local IP address m 255 255 255 0 Netmask g 255 255 255 255 Gateway IP address k 12345678 Encryption key L 3 Log level h 0 Log port C 10 Connection timeout sec V 0 Activity timeout min ou 0 Option Enable UDP oe 0 Option Enable Encryption op 0 Option Enable Permission ow 1 Option Enable Web NET CONTROLLER 21 E NET CONTROLLER User manual
6. DCD Off O Go on line and force to data state Response with CONNECT Vn Verbose response codes VO Numeric V1 Text Response with OK Xn Extended response codes XO Standard X1 X2 X3 X4 Extended Response with OK Escape sequence force to command state Response with OK DTR Off disconnect and force to command state Response with NO CARRIER and set DCD Off DTR On availble for command and listen for connect Ring and force to data state Response with RING CONNECT and set DCD On Response code Code Text X setup LOK 04 1 CONNECT 7 9 2 RING 7 04 3 NOCARRIER 0 4 4 ERROR 1094 1 CONNECT 9600 CONNECT 19200 4 4 CONNECT 4800 4 4 NET e CONTROLLER 5 E CONTROLLER User manual Example on AT strings Example on useable AT strings Init string for extended numerical response codes 2 Connect with IP address 192 168 0 1 ATDT192168000001 CONNECT Connect with IP address 192 168 0 2 and TCP port number 10002 ATDT192168000002 10002 CONNECT Disconnect ATHO OK Entering Command state and keeping the Data connection AT ATO OK CONNECT Figure of Serial port RS232 Signal names defined with Net Controller as DCE Data Communication Equipment 6 NET e CONTROLLER E User Manual CONTROLLER 4 Serial port RS422 RS485 Selectable for 4 wire and 2 wire with half or full duplex and multipoint 2 wire use half du
7. IP 0 0 0 0 gt 0005 Netmask 255 255 255 0 gt 0006 Gateway 255 255 2552255 gt 0007 Serial 1 9600 gt 0008 port 1 Listen 10001 gt 0009 Serial 2 9600 gt 0010 port 2 Listen 10002 gt 0011 DHCP start gt 0012 DHCP stop 192 168 0 168 0001 Shows connection gt 0039 port 1 Connect from 192 168 0 100 20040 port 1 Connect 10001 Send Receive Shows send and receive of data 20020 port 1 1 20021 port 1 Send 1 20022 port 1 1 20023 port 1 Send 1 Close Shows close 20045 port 1 Close 10001 AT command connect Shows connect with adtd Response code 1 Connect 20044 AT Command atdt192168000001 20044 AT Response 1 AT command disconnect Shows disconnect Response code 3 No Carrier 20044 AT Response 3 8 NET CONTROLLER User Manual E NET CONTROLLER 6 Ethernet TCP IP Communication protocol for the network is TCP IP Has support for the following protocols 7 ARP Address Resolution Protocol IP Internet Protocol ICMP Internet Control Message Protocol UDP User Datagram Protocol TCP Transmission Control Protocol DHCP Dynamic Host Configuration Protocol HTTP Hyper Text Transfer Protocol Gateway Net Controller has one default Gateway 8 Web Server Net Controller has an web server for homepages used for configuration NET CONTROLLER E NET CONTROLLER User manual 9 Installation Check with the network administrator
8. Local connect Enable to allow local connection on received characters on serial port If disabled the connection can only be made by remote host Aktiverar lokal anslutning f r serieport 1 Tillater anslutning via serieport 0 Ingen anslutning till ten 1 gt l 1 Serial Option Enable Break signal Enable to send receive BREAK signal over the network for serial port PORT 1 0 k 1 Serial Option Enable RS485 Enable RS422 RS485 interface for serial port OZRS232 1 RS422 RS485 1 gt b 1 Serial Option Enable 485 Multipoint Enable Z state The transmit line is in high impedance if nothing has to sent Used in multipoint environment 1 gt m 1 Serial Option Enable 485 Halfduplex Enable halfduplex The receiver is turned off if a transmit is going on Used in half duplex environment In full duplex mode the receiver is always turned on 0 Full 1 Half duplex 1 gt fz1 Serial Option Enable Termination Rcv Enable low impedance termination 120ohm for receive RS485 0 High termination 1 Low termination PORT 1 gt 0 x 1 Serial Option Enable Termination Snd Enable low impedance termination 120ohm for transmit RS485 O High termination 1 Low termination 1 gt z 1 NET e CONTROLLER 19 E NET CONTROLLER User manual Protocol Enable Text code AT V0 1 Sets the default value for AT command Verbose response codes 0 VO numeric codes 1 V 1 text codes PORT
9. N Hex 00 ff MAIN e 00 02 b8 00 02 01 Identity Identity 8 characters fill out with space Used to give every Net Controller a unique id MAIN iNC9100 Password Password 8 characters fill out with space Used to login for configuration NET CONTROLLER 15 E NET CONTROLLER User manual MAIN gt p control_ Local IP address Net Controller s own IP address Point notation MAIN gt a 192 168 0 10 Netmask Net Controller s own netmask Point notation MAIN gt m 255 255 255 0 Gateway IP address Net Controller s default gateway IP address Point notation MAIN g 255 255 255 255 Encryption key Encryption key 8 digits 64 bits key gt 12345678 Log port Output port for log 0 Turned off 1 Serial port 1 2 Serial port 2 3 Telnet MAIN gt h 1 Log level Level for log Selects level for the printouts 0 Nothing 1 Errors 2 Connections 3 4 Network MAIN gt 1 3 Connect timeout Sets the time for disconnect on idle line in seconds If the communication is hold longer then the selected time the line is disconnected 0 255 Seconds 0 Disabled MAIN gt c 100 Activity timeout Sets the time for restart on idle activity in minutes If the communication is hold longer than the selected time the Net Controller is reset 0 255 Minutes O disabled Main Option Enable UDP Enable UDP instead of TCP Protocol OZ TCP 1 UDP MAIN o u 1 Main Option Enable Encryption
10. and Timeouts is managed over the network with Web browser Telnet or via the serial port with Terminal utility software NCsetup Has Flash memory for easy update of the Net Controller software via the serial port NET e CONTROLLER 3 e NET CONTROLLER User manual 2 Reset button The Reset button R with two functions a short press make a reset and a long press at least in 5 sec start the configuration 3 Serial port RS232 The serial port can be setup with speed data format and control See parameter Baud rate Serial Option Flags Enable 8 Databits Enable Parity Enable Odd parity Enable 2 Stopbits Terminate with character or timeout Received characters is buffered until a defined termination character or a time gap is discovered and thereafter is send via TCP IP The character and the time gap is selectable Default time is 2 characters gap See parameter Serial Receive timeout End character Flow Control For flow control the RTS and CTS is used Normal no flow control is used With this option the RTS control the flow from Net Controller and CTS control the flow to Net Controller See parameter Serial Option Flags Enable flow control Modem mode In modem mode the Net Controller acts as Modem Make it possible to connect with AT command and use IP address instead of telephone number simulate a Modem See parameter SerialOption Flags Enable AT mode Enable ATH command Enable Close via DTR AT 0 1 Def
11. ault value for 0 1 is selectable by this option With AT command VO or selects response code in numeric form VO or text form See parameter Serial Protocol Flags Enable Text code AT VO I AT X0 1 Default value for X0 1 is selectable by this option With AT command or selects response code in standard XO or extended See parameter Serial Protocol Flags Enable Extended code AT X0 X1 ATH Allow disconnect by and ATH command If disabled only disconnect can be made by control signal DTR or timeout See parameter Enable ATH command Enable Close via DTR 4 NET CONTROLLER E User Manual NET CONTROLLER Modem command and data state In modem mode the Net Controller is in command or data state In Command state it is possible to send instruction AT commands In Data state everything is accepted as data Command state Net Controller is shifted to Command state on power up disconnect DTR off and on escape sequence Data state Net Controller is shifted to Data state on connect and ATO Commands AT Command prefix A AT command string must start with this characters except escape DT Connect with IP address The address must be 12 digits without any dots All the digits in the group must be filled out with zeros to three digits number IP Adress192 168 0 1 will be 192168000001 and force to data state Response with CONNECT and set DCD On HO Disconnect Response with OK and set
12. d an IP setting 10 NET CONTROLLER E User Manual NET CONTROLLER Telnet Web browser Make sure your PC is connected to the same subnetwork The Ethernet MAC address of the Net Controller is printed on a label outside of the Net Controller serial number S N 1 Enter IP and MAC address with the arp command use command gt ARP S 192 168 0 1 00 02 B8 00 00 01 2 Start the web browser with the assigned IP address http 192 168 0 1 The start page is showed 3 Enter the password control in Enter password field and click on Ok The IP Settings is showed 4 Select IP settings on the menu Enter the IP address in Local IP field and click on Ok 5 Select Store to Flash memory on the menu Enter yes in Confirm yes no field and click on Ok Net Controller has assigned an IP setting NET CONTROLLER 11 E NET CONTROLLER User manual 10 Test To verify the Net Controller is configurated for the network standard software can be used Ping to verify the IP settings Telnet to verify TCP communication and Terminal to verify the serial port and modem connection IP address 1 Run ping command with the IP address to verify Net Controller is answering if the IP address is correct gt ping 192 168 0 1 example of assigned IP address Verify network communication LED A Active Link yellow blinking TCP 1 Run Telnet with the IP address and the TCP port number that the serial port is assigned to gt tel
13. ers Flash for easy update of software Ethernet IEEE 802 3 10 100Mbps 10Base T 100Base TX RJ45 Serial port RS232 RS422 RS485 complet control signaler DB9F Low power arkitecture with 3 3V logic Watchdog for program execution and restart on fault Integrated power supply for external AC adapter Power indicator green LED o indicate power and started High speed indicator with green LED to indicate 100 Mbps network communications Link Activity indicator with yellow LED to indicate link and network communications Serial indicator R1 and T1 with yellow LED to indicate serial communication TCP IP protocol with support for protocols ARP IP ICMP TCP UDP DHCP and HTTP Power requirements 12 48V AC DC 80mA Physical dimensions NC9100 100 x 95 x 21 mm NC9200 100 x 95 x 38 mm NC9300 88 x 71 x 18 mm Weights NC9100 150 g NC9200 240g NC9300 86 g Ambient temperature 5 50 C normal 40 80 C stock Relative humidity 5 95 none condensing Assembled with case feet case hole or DIN rail CE confirms the requirements for Electromagnetic Compatibility according to EMC directive NET CONTROLLER 27
14. n NET CONTROLLER User Manual NC9100 NC9200 NC9300 Ver 0 4 319001 2004 09 14 E NET CONTROLLER User manual Contents 1 Introduction 3 2 Reset button 4 3 Serial port RS232 4 4 Serial port RS422 RS485 7 5 Log 8 6 Ethernet TCP IP 9 7 Gateway 9 8 Web Server 9 9 Installation 10 10 Test 12 11 Net Controller Program download 13 12 NCsetup Windows 13 13 Configuration 14 14 Default value 21 15 Reset button R 23 16 LED function P H A T R 23 17 Power PW Terminal T4 connector NC9100 NC9200 23 18 Power PW Jack connector 23 19 Network port TP RJ45 connector 23 20 Serial S1 DB9F connector S2 NC9200 24 21 Digital I O Terminal T6 connector NC9200 24 22 Connectors NC9100 NC9200 25 23 Connectors NC9300 25 24 Cable RS232 NC PC 26 25 Technical data 27 Restricted Rights Legend Copyright 1997 2004 WHI Konsult AB All rights reserved No part of this publication may be reproduced transmitted or translated in any form or by any means electronic mechanical manual optical or otherwise without prior written permission of WHI Konsult AB 2 NET CONTROLLER E User Manual NET CONTROLLER 1 Introduction By using Net Controller equipment s with serial communication by RS232 RS422 RS485 be connected to a standard Ethernet network with TCP IP The communication is completel
15. net 192 168 0 10 10001 example of assigned IP address and TCP port number Verify that it connects 2 Send receive data by pressing a character key Do loopback test by connecting TD RD on the serial port gt 112233445566778899 Local Echo on Serial port 1 Run Terminal program and choise a com port with Modem You have to use a Modem it is not possible to enter the AT command characters one by one If no Modem is installed choise a standard Modem 9600 Enter the Net Controllers IP address as telephone number You have to use fix length on the number fill out with leading zeros on each group so the number 12 digits 192 168 0 1 etc 192168000001 2 Connect with IP address as Telephon number After connection all characters is send 3 Disconnect Network Serial port Verify the communication via the network and the serial port by running both the Telnet and Terminal together 1 Run the Telnet via the network 2 Run the Terminalprogrammet via the serial port 3 Connect the Telnet to Net Controller s IP address and TCP port 10001 4 Enter character from the Telnet and they will be showed on the Terminalen and reversed 12 NET CONTROLLER E User Manual NET CONTROLLER 11 Net Controller Program download Download of new software Firmware to upgrade the Net Controller The software file type is ihx The download can only be done via the serial port with NCsetup The latest version for the Net Con
16. onnector NC9100 NC9200 Pin Text Name Decsription 18 Power PW Jack connector P ume eei m 12 48V AC DC 19 Network port TP RJ45 connector 10Base T 100Base TX NET e CONTROLLER 23 E NET CONTROLLER User manual 20 Serial S1 DB9F connector S2 NC9200 are ype Input ome 21 Digital I O Terminal T6 connector NC9200 no mu oma ours output Dual out ours output Dutt out Digital in 1 catode OUTO Digital out 0 OUT1 Digital out 1 6 jop Ground Signal ground Position top of terminal 24 NET CONTROLLER E User Manual NET CONTROLLER 22 Connectors NC9100 NC9200 Figure on connections for serial ports Figure on connections for Power T O port and TP port 23 Connectors NC9300 Figure on connections for serial port and power Figure on connections for TP port A TP H R NET e CONTROLLER 25 E NET CONTROLLER User manual 24 Cable RS232 NC PC 31 60 01 RS232 cable NC PC Serial cable for RS232 to PC DB9M Male DB9F Female DB9M DB9F 1 gt DCD black 1 2 gt RD brown 2 3 lt TD red 3 4 lt DTR orange 4 5 GND yellow 5 6 gt DSR green 6 7 lt RTS blue 7 8 gt CTS violette 8 9 gt RI grey 9 26 NET e CONTROLLER User Manual E NET CONTROLLER 25 Technical data Processor 32 bits Risc 33 MHz Data memory 256 Kbytes SRAM for stack and buff
17. parity PORT 1 gt 0 o 1 Serial Option Enable 8 Databits Select the number of data bits for the serial port between 7 or 8 027 Data bits 0 8 Data bits gt d 1 Serial Option Enable 2 Stopbits Select the number of stop bits for the serial port between 1 or 2 0 1 Stop bit 1 stop bits PORT 1 gt 0 s 1 Serial Option Enable Flow conirol Enable the flow control for serial port On flow control the control signal RTS is used for data from Net Controller and CTS is used for data to Net Controller PORT 1 0 c 1 18 NET CONTROLLER E User Manual NET CONTROLLER Serial Option Enable AT mode Enable Modem mode and use AT commands All command strings must start with the prefix AT DTR must be On The line goes disconnected by ATH command or set the DTR Off 1 gt a 1 Serial Option Enable ATH command Enable detect of ATH command In this option the Net Controller is disconnect by timeout or control signal DTR PORT 1 gt 0 h 1 Serial Option Enable Close via DTR Enable close with control signal DTR By set DTR Off the Net Controller disconnect PORT 1 o t 1 Serial Option Enable Remote connect Enable to allow remote connections from remote host If disabled the connection can only be made locally by received characters on serial port Aktiverar anslutning externt f r serieport 1 Till ter anslutning till TCP port 0 Ingen anslutning till ten 1 gt r 1 Serial Option Enable
18. plex and multipoint select b 1 m 1 f 1 Signal levels Mark 1 T R T R idle Space 0 T R T R See parameter Serial Option Flags Enable RS485 RS485 Interface For DIN rail model the option for RS485 must be set Se parameter Option RS485 Interf Halfduplex When half duplex is set it shifts between Transmit and Recive It is used for 2 wire system See parameter Serial Option Flags Enable 485 Halfduplex Multipoint Activate Transmit in none active state free when data s not transmitted It is used for 2 wire system See parameter Serial Option Flags Enable 485 Multipoint Low high impedance The termination can be selected to low 120 ohm or to high 12 k ohm impedance terminating See parametrar Serial Option Flag Enable Terminate Snd och Enable Terminate Figure of serial port RS422 RS485 Shows 4 wire and 2 wire NET e CONTROLLER 7 E NET CONTROLLER User manual 5 Log To monitoring what the Net Controller is doing the log output can be used It is possible to select output port and log level The output can be serial port or Telnet To select the port 1 Serial port 1 2 Serial port 2 3 Telnet To select level 0 Nothing 1 Errors 2 Mini 3 4 Network See parameter Log Port Log Level Example on output Start Shows version and IP settings gt 0002 NC200 STD 0 72 gt 0003 Ethernet 00 02 b8 00 11 89 gt 0004 Local
19. s is managed over the network with Web browser Telnet or via the serial port with Terminal utility software NCsetup To start configuration via the serial port 2 press the button R Reset long press After the configuration is completed the Net Controller is turned back to data mode by either storing the parameter or by pressing the R Reset button short press To configurate with Telnet or Webserver over the network start either Telnet with telnet port or web browser Terminal and Telnet use the same command syntax CMD Command language CMD Configuration via Terminal or Telnet use the same command syntax CMD Each command consist of one command letter and argument and value To only show the parameter enter only the command With command shows a list of all commands Setting of the serial port is done by a sub menu 1 it also has ti s own list of commands 2 Back to the main menu by the key Esc To make changes a login must first be done Finish the configuration with Store to Flash or Exit Login Login with password control Show menu Show a list of commands MAIN gt Main menu NC200 STD 00 72 j nnnnnnnn Check password f Enable service enn nn nn nn nn nn Ethernet MAC address i nnnnnnnn Identity p nnnnnnnn Password a nnn nnn nnn nnn Local IP address mnnn nnn nnn nnn Netmask gnnn nnn nnn nnn Gateway IP address k nnnnnnnn Encryption key Log level 0 7 0 Off hn Log port 1 Port 1 2
20. t 2 menu PORT 1 gt Esc MAIN gt Baud rate Set communication speed for serial port Speed 300 115200 bps PORT 1 gt b 9600 NET CONTROLLER 17 e NET CONTROLLER User manual Serial recieve timeout Sets the time for received time gap for serial port Time value x 4 x Bit period 0 255 0 disabled PORT 1 gt t 10 RS485 timeout Sets the time for activate Receive after Send for serial port RS485 in milliseconds 1 255mS O disabled PORT 1I gt t 5 Local TCP port Net Controllers own TCP port number for serial port Use number higher then 5000 PORT 1 gt p 10001 Remote IP address IP Address for the remote connection for serial port Is the host the Net Controller is connected to on data received on serial port Point notation PORT 1 a 192 168 0 200 Remote TCP port TCP port number for the remote connection for serial port Is the host the Net Controller is connected to on data received on serial port Use number higher then 5000 PORT 1 p 10001 Start character Not used PORT 1 gt s 02 Stx End character Set the terminating character for received messages The received character is buffered until a termination character or a time gap obtained PORT 1 e 03 Etx Serial Option Enable Parity Enable the parity for the serial port Aktiverar paritetskontroll f r serieport PORT 1 0 p 1 Serial Option Enable Odd parity Select the parity for the serial port between odd even 0 1 odd
21. troller can be dowloaded from our website www whi se Download Connect an Terminal PC to serial port S1 and start the NCsetup 1 Start the configuration by pressing the button R Reset long press 2 The following text shows Configuration mode Net Controller NC200 STD 01 00 Enter password J gt 3 Enter the password with command gt j control 4 following text shows Configuration open MAIN gt 5 Set the Net Controller in waiting state for download with the d command MAIN d 6 The following text shows Waiting for download 7 Select File Download in NCsetup menu Choose the download file in file window and click Ok NC200 STD 00 72 ihx 8 Platform and current version shows in Download window Click on Start The download is started 9 The download is completed then the Download window is closed Net Controller restarts If wrong download file is loaded and the Net Controller fault to start it is possible to force the Net Controller into waiting for download by pressing the R Reset button at the same time power is connected 12 NCsetup Windows NCsetup is a terminal program used to communicate with the Net Controller via the serial port Install Unpack and copy the file ncsetup zip to a map Consist of one file ncsetup exe NET e CONTROLLER 13 E NET CONTROLLER User manual 13 Configuration Configuration of parameters such as IP addresses TCP ports Serial communication and Timeout
22. y transparent Ethernet with TCP IP offers a well thought and open architectur for communication on different platforms regarding computers and operating systems Gives advantage in form of easy integration By using the network instead of own serial cables and telephone line for modem it is possible to reduce the costs for installation and maintain Net Controller is a general standalone product and easy to integrate in systems Two models is available table and DIN rail model Is power supplied With 12 48V AC DC Direct or with an AC adapter Each Net Controller has its own IP address and each serial port has its own TCP port number Handle subnets with one standard Gateway and Netmask addressing Net Controller has two serial ports it can be used for different equipment with separate remote IP address connection The communication is completely transparent The serial port has following signals GND Ground RD Receive Data TD Transmit Data DSR Data Set Ready DTR Data Terminal Ready RTS Request To Send CTS Clear To Send DCD Data Carrier Detect RI Ring Switchable between RS232 and RS422 RS485 interface RS422 RS485 can handle 4 wire and 2 wire connections In modem mode it can simulate Modem with AT commands This function makes it possible to replace a Modem with a Net Controller and connect is made with IP address instead of telephone number Configuration of parameters such as IP addresses TCP ports Serial communication
Download Pdf Manuals
Related Search
Related Contents
Universal H-Series Troubleshooting Guide 800 SX-R JET SKI®Watercraft Service Manual UBCINET TRE Supermicro SuperServer 7044H-82R+B, Black about the leroy package for sibelius DULCODOS® Pool DSPa: DH1 Bedienungsanleitung Manual del usuario User`s Manual - Trail Tech Gallery Copyright © All rights reserved.