Home
USER MANUAL THERMAL CAMERA KT-160
Contents
1. 3 9 Camera Settings M When the screen is not showing any menu press button and the following function selection will be displayed Parameter File Setup KT 160 USER MANUAL 21 Parameter At any time the user may exit setup menu by pressing the trigger button 10 After selecting the Setup button Pr L a sub menu is opened allowing user to set own camera parameters language temperature units time date type of lens type of video output signal temperature alarm thresholds or choose the default a The selection is done by using the arrow keys up or down buttons LE U VL Mi Restored Parametre 16 Defaull TimeDate EE mh Lene PA LINTSC AlarmTemp Mo i 3 9 1 Restoring default settings Select Default and accept it by pressing OK to go to menu Restoring default settings 22 KT 160 USER MANUAL F Ex Press Yes button to confirm default settings select No button Lak or press the trigger button 10 to m without saving changes After selecting default settings the following parameters are switched emissivity factor 0 98 ambient temperature measured automatically distance from the object 1 8 m colour palette 2 relative humidity 70 laser locator Off alarm temperature 100 C 212 F lens standard 11mm 3 9 2 Selection of the user interface language Select Language and accept it by pressing OK to go
2. Menu Measure command Show path view This command displays a graph of temperature changes for the displayed object point segment area in the real time For the point current temperature will be displayed For the sections and areas the maximum minimum or average temperature value will be displayed The command should be selected after locating selected object on image of the object for which the temperature will be analysed MIES al Sree J20 42 KT 160 USER MANUAL After clicking chosen object a window opens allowing the user to change the colour line and the transparency of selected object ck E A Shera wer pow E apr hr Three tumparatLen Fister fra ener Tere Targa 0 ce p Fae r PUPE Enia E hA ni bpe skure cw Double clicking with the left mouse button on window View path opens a dialogue box where the user can change its settings background colour the axis lines on the graph the maximum and minimum temperature on the axis To accept the changes click OK and to return to the previous settings select Cancel Tracz Firm JER lakk eig EE sem FA Fear A sm 0 T Flaa Tam hrs TE ki NOTE The chart line is in the same colour as the selected object s colour Because the colour of the graph line depends on the colour of an object we can analyse using a single window the temperature changes in many points and areas Pressing function key F11 on the PC keyboa
3. After selecting KT 160 and when properly connected a window is opened which shows a real time video image Analysis Play Pause Calibration ohiact Capture Full screen kidani 1978 Record 4 In the real time the user can start or stop recording manipulate and adjust the shutter Functions indicated by assigned shortcuts described in the video window b Plays the video During playback when pressed stops the video LE Stops playback Another pressing resume playback from the point where it was stopped 38 KT 160 USER MANUAL Pb During playback mode fast forwards frame by frame 4 in playback mode rewinds frame by frame Records video saving it in a continuous mode in the in the directory defined in settings The program names the file automatically After stopping and re pressing records another file NOTE The 9 button is used both to start and stop the recording of IR video sequences Additional features available from the computer function keys F2 Shutter operation F3 Focus adjustment zoom in F4 Focus adjustment zoom out NOTE After moving the cursor to any displayed point current temperature of that point is displayed 5 4 2 Commands available in IR video mode After performing the procedure described in section 5 4 1 the appearance of the menu bar changes upper part of Sonel ThermoAnalyze features specific for IR video mode are available Described below are the comm
4. 3 11 1 Using the AC adapter Connection of the AC adapter is indicated by the charging indicator 2 If the camera is turned off the indicator indicates battery charging status After switching the camera on press and hold button w for 2 seconds the indicator will flash for a while changing colour form green to red at a rate of 3 times per second and then during the self check it switches to continuous red light When the camera is turned off if the AC adapter with power supply is still connected the indicator will indicate the battery charging NOTE Do not connect the AC adapter if the camera is powered by non rechargeable batteries Connecting the AC adapter to such batteries creates the risk of explosion and damaging the camera 3 11 2 How to use batteries and rechargeable batteries After switching on the camera powered by batteries rechargeable batteries the indicator will flicker alternately in green red for a few seconds after turning on the camera During operation the indicator is blank NOTE Low level of batteries rechargeable batteries is indicated by message Battery low in the upper right corner of the screen 3 11 3 Charging rechargeable batteries When the camera is turned off and contains rechargeable batteries connecting the AC adapter and charging is indicated by a slower flickering approx 1 per second of the charging indicator 2 After rechargeable batteries are charged the indicator is
5. SSner USER MANUAL THERMAL CAMERA KT 160 SONEL SA ul Wokulskiego 11 58 100 Swidnica Version 1 03 19 07 2010 KT 160 Thermal Camera complies with current EU directives relating to electromagnetic compatibility and safety Thank you for purchasing our thermal camera KT 160 is a modern easy and safe measuring device Please acquaint yourself with the present manual in order to avoid measuring errors and prevent possible problems related to operation of the camera All products of Sonel S A are manufactured in accordance with Quality Management System which is approved to IS09001 2008 for the design manufacturing and servicing Due the continuous development of our products we reserve the right to introduce changes and improvements in the thermal imaging camera and in the software described in this manual without prior notice Copyrights Sonel S A 2010 All rights reserved This manual may not be copied reproduced translated or transferred to any electronic carriers or in machine readable form in whole or in part without the prior written consent of Sonel SA 2 KT 160 USER MANUAL 1 2 3 TABLE OF CONTENTS SAFETY ass ASA 5 FUNCTION BUTTONS AND MENU aicissctssisasscesscessctcesesccusicesenesscasscusccuscinasteractene 7 2 TOT v rteren 7 Ze SEN EEE EE ET RENE PET 7 CAMERA CONTROL AND ADJUSTMENT sessssvvvvvsvvssssssessssssnnnnnnnnsssssssssessseenee 9 3 1 SWITCHING THE CAMERA ON L OFF senil OR
6. a year or move to months settings then set the month and or move to day settings and then save the settings and exit the menu without saving them by pressing the trigger button 10 NOTE The date is displayed as month day year 3 9 5 Lens selection Lens option allows the user to choose between standard lens 11mm or additional telephoto lens 30mm Additional telephoto lens may be selected only after its installation After installing additional lens 30mm the camera automatically switches into the corresponding lens mode The use of an additional 30mm lens is described in chapter 9 1 NOTE Attaching detaching additional lens should be performed when the camera is switched off 3 9 6 External display and selection of video signal type Choosing PAL NTSC allows the user to switch the display from the LCD screen of the camera to an external display and to select the type of video signal PAL or NTSC External monitor should be plugged into the camera interface 12 using the supplied cable When you select this option the user may choose as follows After selection the user must confirm the choice by pressing Yes or No because after choosing PAL or NTSC the image is no longer displayed on the screen of the camera and is displayed only on a connected external display including menu bars and buttons 24 KT 160 USER MANUAL descriptions therefore if the user select PAL or NTSC an additional warn
7. addition vibrations cause the blurring of images Additional handle WAADASTATYW1 allows the user to mount the camera on a tripod 9 3 Working in conditions of intense illumination When working in bright places strong sunlight strong internal lighting the image on the screen becomes very difficult to see Additional lens hood WAPOZOSL2 mounted on the camera above the screen allows the user to work in such adverse conditions an E KT 160 USER MANUAL 53 10 Cleaning and maintenance NOTE Use only the following maintenance methods Camera housing all non optical surfaces of the camera can be cleaned when required with a soft cloth dampened with water and a standard mild detergent Do not use any solvents or cleaning agents which might scratch the casing powders pastes etc During cleaning the camera must be switched off The lens of an IR camera due to their anti reflective coating are the most sensitive and expensive part of the camera the lens is critical to the radiometric capabilities of the system Therefore after each use of the camera the lens cover must be attached The optical surfaces should be cleaned only when visibly dirty Do not touch exposed surfaces of the lens with fingers because dirt left by the fingerprints may be harmful to coatings and lens glass To clean the optical viewfinder and particularly camera s optics and accessories do not use any chemicals Use a clean dry and soft tissu
8. to sub menu Select user s interface language The user may choose between Polish English Spanish and LF Me Russian The choice is made by using the arrow keys buttons N and confirmed by pressing OK button LER 3 9 3 Selecting temperature units Select C F and accept it by pressing OK to sub menu Selecting temperature units LEA where the user can choose between C button degrees Celsius or F e i i button degrees Fahrenheit Pressing button or the trigger button 10 results the camera to exit the current setting without saving changes 3 9 4 Setting time and date Select Time Date and accept it by pressing OK to go to sub menu Setting time and date which allows the user to set the internal camera clock and calendar The files will be saved with date and time according to indications of the camera clock KT 160 USER MANUAL 23 LF After selecting Time a the camera switches into time regulation mode and buttons LE and kul allow the user to set the time Minutes option button j m Pr is used to set minutes where minutes may be set as described above or move to seconds settings After the clock is set it is displayed during adjustment above the menu bar the user may save chosen settings by pressing OK or exit the adjustment menu by pressing the trigger button 10 Similarly after selecting date setup the user may set and
9. 11 4 General principles regarding using Ni MH rechargeable batteries 29 KT 160 USER MANUAL 3 4 PRECISE TEMPERATURE MEASUREMENT Qseeeoooeeeeeeeeeeennnnennnennnnennennnnnnnneee 31 5 INFRA RED FILMING 2220020000000000000000000000000000000000000000000000000000000000000000000000 32 5 1 INSTALLING THE CAMERA DRIVER arrornrnernrnennrnennnnennnnennrnerernenennenennenennnnennnnennnnenenn 32 dd Hardware FEGUWEMENI usd oO lo Zd OE Alto 32 SWI Vil 32 3 2 INSTALLING SONEL THERMOANALYZE SOFTWARE vi cccccccccccccuccececcccucuscccuccucuseecuees 35 55 CONFIGURATION OF SONEL THERMOANALYZE SOFTWARE ccccccceccccecccceccecuceecess 36 5 4 RECORDING AND PLAYBACK OF IR VIDEOS ccccccccccccccuccuccucceccscuccucsucscuscuceusuccusencs 37 5 4 1 Infrared video in redl time mode uggs NAAS 32 5 4 2 Commands available in IR video mode cc cccccccccccuccuccuccucccccuccecuscuceucenss 39 5 4 3 Data record and analysis az dia Aa dA od ah 45 6 DATA TRANSMISSION AND ANALYSIS s oooosoooooooooooooooooo0o000000000000000 46 6 1 READING THE EXTERNAL MEMORY SD CARD serrrrrrnnnnnnnnnnnnnnnnrnnnnnnrrrrrnnnnnnnnnnnnnnnnr 46 6 2 USING THE INTERNAL UFLASH MEMORY cccccccececcccecuccccccececusscscscucusecuscseusususnees 46 6 3 VINN 47 7 TECHNICAL SPECIFICATIONS sun eeeeeere seeders ned 48 8 OVERVIEW OF EMISSIVITY FACTOR FOR VARIOUS MATERIALS 50 9 USE OF ACCESSORIES ske 51 9 1 TEEEPHOTO LENS INN OGR A NEA OO OKO AL
10. 50 MB JPG with thermograph data real view image File Format and voice annotation Voice Annotation up to 60 sec per image Power System AA rechargeable batteries with the option to use non Battery Type rechargeable AA alkaline batteries Charging System Built in camera charger Battery life Over 3 hours of continuous operation External power supply AC adapter 110 230 VAG 50 60Hz Environmental Specifications Operating temperature 10 C to 50 C Storage Temperature 20 C to 60 C Humidity Working and storage 10 to 95 non condensing Housing IP54 IEC 529 housing Shock Operating 25G IEC 68 2 29 Vibrations Operating 2G IEC 68 2 6 Communication Image Transfer thermal and real measurements and voice annotations to a PC transfer of live video Live transfer to a PC Physical Characteristics Weight 0 73 kg with batteries 141 mm x 124 mm x 240 mm KT 160 USER MANUAL 49 50 8 Overview of emissivity factor for various materials BIUMI IUIME surs t 0 05 oxidized aluminium eaaeaa aaa aan aaa anaanaanaanannanna 0 30 SPA sn 0 90 cement ana CONCICIC vasset en 0 90 ME 0 15 18a E ENEE EE EENE A E POE 0 09 PA AISNE 0 05 KOCZDRICK ste 0 93 EE AEE dO Er 0 40 9 LE 0 I EE EE TE 0 85 618 02 Jer O eee Rea 0 18 mMamesUN hvad 0 12 DESS 0 10 OXIOIZEG Dass ie OOO AEO POOL ee 0 61 BIE CINE 0 15 EET SE rece eee 0 16 OXMIJIZECAJCAO ind o RAE a 0 63 Pia un UNI Zayed Pa Z PRO R cmeetat
11. ANA GACKA OOOO 51 9 2 VEORKING ON A TRIPOD see eee 53 9 3 WORKING IN CONDITIONS OF INTENSE ILLUMINATION 0cccccececceccecceccecccuccuceececs 53 10 CLEANING AND MAINTENANCE ss ssoosooooooooo0000000000000000000000000000000000000000 54 IE CALIBRATION NNN 54 gt TORNER 54 I FOUIPMENP GAWRON 55 14 DISMANTLING AND UTILISATTION ss osoosoosoooooooooooooooooo0o000000000000000000 56 15 MANUBAG TURER na 56 4 KT 160 USER MANUAL 1 Safety Before you proceed to operate the camera acquaint yourself thoroughly with the present manual and observe the safety regulations and specifications defined by the producer Any application that differs from those specified in the present manual may result in a damage to the device and constitute a source of danger for the user The camera must not be used in rooms where special conditions are present e g fire and explosion risk It is forbidden to use damaged or malfunctioning camera When the camera is not used for a long time remove the batteries Battery spill and damage to the camera may occur if discharged batteries are left in the meter Do not use the camera with half closed or opened battery cover and do not use any other adapter than the one supplied with the camera Repairs may be carried out only by an authorised service point KT 160 Thermal Camera is designed to measure and record the images in the infrared The camera is constructed in a manner which gives you ma
12. O 9 5 2 FOM 9 3 3 TEMPERATURE RANGE eee 10 3 4 IMAGE MODES set GOA O AOR CE ces iii ia iii 12 A MANUAL CALIBRATION asd dA Olaa 15 3 6 ERT RR 15 5 7 CAPTURING AND RECORDING THE IMAGE WITH VOICE ANNOTATION 15 3 8 FUNCTION ENGS sara 17 3 8 I SELO ODI CCLCMISS VID APA AERO LAO at 18 3 0 2 Ambient temperature senn sr 19 3 8 3 Selecting the colour palette rrrrrrnnnnnnnnnnnnnnnnrnonrrrnnnnnrrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 19 3 8 4 Setting the distance from an object 21 3 8 5 TT re 21 3 8 6 ACUVATING the laser TOO mesire Eda AA dE stead ahaa 21 3 9 CAMERAS ETTING S ve eee 21 3 9 1 Restoring JA SENG see PE 3 9 2 Selection of the user interface language 23 3 9 3 Selecting temperature UNIS se 23 3 9 4 Selline time ANA GOL 3 sze naei E E a N a 23 3 9 5 VESLE EEE EE EE NE A ii 24 3 9 6 External display and selection of video signal type 24 3 9 7 Setting the value for temperature alarm 25 3 10 SETTING AND VIEWING FILES INFORMATION srrnrnnnrrrnnrnnnrnrnrnrnnrnnnrnrnsnrnnrnnnrnrnsenesenn 25 3 10 1 Preview of stored images and deleting single images from memory 26 BADD Ds N T IMAGES Wn OE l AJ LO AO A 3 1030 SCICCHNS GINCM ON moss SWR seni GEE aac UGA ASA Por DE ND 27 3 10 5 Information about hardware and software Version oee 27 SAL POWER SUPPLY BATTERY CHARGING Ave area EEE kes mates A SILI ghetto 28 3 11 2 How to use batteries and rechargeable batteries o on 28 3 11 3 Charging rechargeable batteries 28 3
13. alyze Sonel software e Wrist strap WAPOZPAS 1 e Case WAFUTM6 e Transport case WAWALL3 e External memory card reader with USB cable WAADAUSBMEM e Gloves cloth Optional accessories e Holder for mounting the camera on a tripod e Sun visor WAADASTATYW1 WAPOZOSL2 e elephoto lens 30mm WAADATO30 KT 160 USER MANUAL 55 14 Dismantling and utilisation Worn out electric and electronic equipment should be gathered selectively i e it must not be placed with waste of another kind Worn out electronic equipment should be sent to a collection point in accordance with the law of worn out electric and electronic equipment Before the equipment is sent to a collection point do not dismantle any elements NOTE Observe the local regulations concerning disposal of packages worn out batteries and accumulators 15 Manufacturer The manufacturer of the device which also provides guarantee and post guarantee service is the following company SONEL SA Wokulskiego 11 St 58 100 Swidnica Poland e mail export sonel pl Homepage www sonel pl NOTE Service repairs must be realised solely by the manufacturer Made in PRC 56 KT 160 USER MANUAL
14. ands related only to operation in the real time all commands including those related to playback and analysis of recorded data are described in detail in the operating instructions of supplied software Menu Video command Palette It allows the user to select the palette to be used for displaying infra red images in the real time There are nine colour palettes available The palette may be also changed using Image Palette window if it is not displayed it may be displayed after pressing button on the toolbar Image Palette ax Palette 45 bb KT 160 USER MANUAL 39 An exemplary images in different colours are shown in section 3 8 3 pallet 9 is a negative of pallet 1 Menu Video command Set automatically It allows the user to set automatically or manually set the colour range for temperatures In the automatic mode the system automatically selects the optimal settings In the manual mode the user can select the temperature range for the palette setting minimum and maximum temperature for displayed colours NOTE Any adjustment of the range see next command changes the range and switches the image into the manual mode Command Set automatically restores the automatic mode at any time Menu Video command Tool setup Activates the control of temperature colours for each open video file After selecting the function below the thermogram the adjustment bar appears as shown below it allow
15. are given in the Emissivity Table Section 8 Poorly chosen value of the emissivity factor may cause significant reading errors for the temperature therefore KT 160 camera allows the user to choose the emissivity factor within the range of 0 01 1 00 see chap 3 8 1 Measurement accuracy also depends on the ambient temperature he default temperature is the temperature measured by the camera and this value may be changed manually to compare and establish a proper relation between measured object s temperature and certain types of the ambient temperature e g sky snow Adjustment of the ambient temperature is described in Chapter 3 8 2 The influence of the distance from the object on the measurement accuracy may be significant depending on the medium in which the object is located air fog smoke and its impact on the attenuation of thermal radiation It is possible to adjust the default value 1 8 m in the range of 0 1 30m The method of the distance adjustment is described in chapter 3 8 4 Relative humidity may also influence the accuracy of measurement it is possible to change the default value 70 for a value from the range of O 100 the function described in section 3 8 5 In addition in order to get an accurate temperature reading the user must hold the camera steady and set the focus very well Section 3 2 KT 160 USER MANUAL 31 5 Infra red filming Infra red video can be recorded with KT 160 came
16. ased Still the area with the highest temperature and the central measurement point of analysed area are indicated the values of corresponding temperatures are shown in the bottom left corner max maximum temperature cen the temperature in the central point 14 KT 160 USER MANUAL Pressing button or the trigger button 10 results the camera to exit the current setting and enter into infra red image mode 3 5 Manual Calibration This camera during its operation regularly performs the calibration it is indicated by letter C in the green rectangle appearing in the upper left corner The calibration may be activated manually at any time When the screen is not showing any menu shortly press button and simultaneously press the trigger button 10 The calibration will be performed and indicated similarly to the automatic calibration 3 6 Laser locator Laser locator may be activated when the screen is not showing any menu by pressing and holding button activation occurs after about 1 5 seconds and it is turned off after releasing or pressing the trigger button NOTE The laser beam may damage your eyes in case of contact therefore DO NOT DIRECT YOUR EYES TOWARD THE LASER BEAM and do not direct the laser beam toward people and animals Pay particular attention as the laser beam can reflect off the shiny surfaces For security reasons the function is available if the laser has already been act
17. continuously green Quick flickering of the indicator during the charging process indicates an irregularity e g reverse battery position or damage in such a situation it is essential to stop charging and check the cause of an irregularity In the case where only irregularity is a high battery temperature loading should be stopped until batteries are cool Ni MH batteries do not require full charging discharging during the operation but it is recommended to charge them fully during the first 3 charges Rechargeable batteries should be replaced all at once do not use new batteries together with used do not use batteries of different types 28 KT 160 USER MANUAL NOTE Use only the AC adapter supplied with the camera NOTE Never remove rechargeable batteries from the camera while charging NOTE Pay attention to the polarity of rechargeable batteries standard batteries while inserting them into the camera NOTE Charging batteries should be carried out at the temperature of 0 40 C 3 11 4 General principles regarding using Ni MH rechargeable batteries When the camera is not used for a long time remove the batteries and store them separately Store the rechargeable batteries in a dry cool and well ventilated place and protect them from direct sunlight The temperature of the environment in the case of prolonged storage should not exceed 30 C If the rechargeable batteries are stored for a long time in a high tempe
18. e is 0 98 Sample values of emissivity for various materials are given in Chapter 8 3 8 2 Ambient temperature settings Select Tamb and accept it by pressing OK to go to sub menu Setting ambient Pry er temperature By pressing Setup Pal the camera is switched into the manual mode F Me where the or buttons Fs z Mish are used to decrease increase the value of the ambient temperature within the range of 40 0 85 0 C By pressing the OK Pa the user accepts a new value This function allows the user to set the proper relation between the ambient temperature and the temperature of tested objects it is useful when measurements are made from a distance for example from a room with a different temperature than the ambient temperature of the measured object Further activation of this function and exiting it causes the camera to switch into the automatic mode For most measurements there is no need for manual adjustment 3 8 3 Selecting the colour palette Select Palette and accept it by pressing OK to go to sub menu Selecting one of eight F M pallets By pressing lt or gt button Mi the user may select one desired pallet to represent temperature mapping Changes are confirmed by pressing OK Pe KT 160 USER MANUAL 19 Available colour palettes e 2 Pe F x ed ij Ae gg g m The default palette is no 2 20 KT 160 USER MANUAL 3 8 4 Setti
19. e to clean the body of the viewfinder and only supplied tissue to clean optical part of the lens 11 Calibration To ensure the accuracy and reliability of thermal imaging camera it is recommended to calibrate the device every 12 months Detailed information on laboratory services may be obtained by calling 74 85 83 879 or via e mail serwis sonel pl NOTE KT 160 Thermal camera has no parts that could be repaired by the user Do not attempt to disassemble or modify the camera Opening the device will void the warranty 12 Storage In the case of storage of the device the following recommendations must be observed e make sure that the camera and its accessories are dry e during prolonged storage remove the batteries e storage temperatures must be in accordance with those defined in technical specifications e in order to prevent total discharge of the rechargeable batteries during prolonged storage charge them from time to time 54 KT 160 USER MANUAL 13 Equipment Standard set of equipment supplied by the manufacturer includes e KT 160 Camera WMPLKT160 e nfra red lens focal length of 11mm with a protective cap mounted on the camera e Front cover WAPOZOSL1 e SD Memory Card 2GB WAPOZSD1 e 12 AA rechargeable batteries e Universal AC adapter 110 230V WAZASZ8 e USB cable WAPRZUSBMNIBS5 e Video cable e CD containing Sonel ThermoAnalyze software and the driver e User manual e User Manual for ThermoAn
20. emperature Tmax 10 KT 160 USER MANUAL S Hup cha Uper Limit of he T mperabure Tmax LF M By pressing buttons or the user increases decreases the upper temperature range shown on the thermogram changing value is additionally marked with a red line 1 Pressing button LSA causes switching into the mode for setting the lower limit temperature which can be adjusted in the same way as the upper limit temperature Fu Mi j using Fa buttons and M Setup tho Lower Limit o f Temperature Tmln Pr Pressing button gt causes switching into the mode for setting the upper limit temperature By pressing the trigger button 10 the user accepts the temperature range selected manually KT 160 USER MANUAL 11 After choosing the automatic or manual range information about this appears for 2 seconds in the upper left corner of the screen message on a green background In addition when manual range is chosen digits on the temperature range bar will be shown in brown in automatic mode in white 3 4 Image modes Pi When the screen is not showing any menu press and shortly hold button Pa It results in displaying the selection screen for selecting one of the three picture modes ee Visual 1 If you select Visible button the camera will show on the screen only the visible image In order to return to infra red image mode press the trigger button 10 2 Point function
21. enables user to change the location of the point the centre of the screen is its default location for which the temperature value is always read and shown After selecting this function pressing button t the screen looks as follows 12 KT 160 USER MANUAL UpiDown Fa Pressing button Fa causes the temperature reading point to shift left while pressing M H button to right new coordinates in relation to the centre of the screen are displayed Pi and the point is marked with blue lines pressing switches into the mode Up Down where buttons 5 Me change the location of the point vertically and button pri switches into Left Right mode Regardless of the change in the position of the centre point the screen continuously displays the indicator of the maximum temperature Pressing the trigger button 10 causes the camera to exit Point mode and return the temperature reading point to the centre of the screen KT 160 USER MANUAL 13 3 Fusion Mode Pa After choosing Fusion mode button Pal the screen shows a visual visible image combined with the thermal image in such a manner that the thermal image is in the centre of the screen cen 30 5 The bottom of the screen displays a slide bar representing the proportion of combined images when it is moved to the left button the intensity of the thermal image is reduced and moving it to the right Pal the intensity is incre
22. end Santee 0 10 SOO ER 0 95 NE PERON 0 03 FDIC PORA 0 85 HAN vaere Nese 0 30 OR 0 90 WOM AM solace corkse Grek on ec acts te enced cared ose raked 0 13 oxidized wolfram uaau aaa aaa aaa aaa aanaanaaaaaasaasaana 0 11 SO eat ct EO al 0 02 iron and steel aaeaa aaa aan aan aaa aaa N E E 0 16 oxidized iron and steel usaaaanaanaasansanaa 0 85 KT 160 USER MANUAL 9 Use of accessories The user may use additional accessories for measurements In order to purchase them please contact the manufacturer or the distributor of Sonel SA equipment The list of standard and additional accessories is presented in chapter 13 9 1 Telephoto lens 30mm Additional Telephoto lens WAADATO30 may be useful in situations where the user can not approach the object and obtain a distance sufficient for measurements Below there is an example of such a situation where the test object was at a significant height Thermogram and InfraFusion image captured with a standard lens 11mm RUSE ey inja trinn im eg ae ee ome Characteristics of 11mm lens Lens 11mm ee KT 160 USER MANUAL 51 Thermogram capture with an additional lens 30mm A AJ m m 4 2 jer FAWL 31 1 27 7 G B Characteristics of 30mm lens Lens 30 mm 52 KT 160 USER MANUAL 9 2 Working on a tripod Prolonged holding the camera during the work may be tiring in
23. ermines the number of recorded frames per second default 25 Default Palette sets the palette used in video mode Kinescope rate determines which frame of the image is stored e g 1 each 5 one in five In some situations there is no need to record all frames it helps to save disk space Update path view data refreshing rate for each point 5 4 Recording and playback of IR videos 5 4 1 Infrared video in real time mode Command Firewire Video enables the user to download video directly from the camera kraj CH C E E EEE FI ae ae OURDIDIE2 bg i zc noe _ TM py 2 20050 8 Em EE gen ROBA pg r Ea I Piima Caisin ar BOI S KE Rg T SKE TER Ax E SG The camera must be connected to a computer using USB cable supplied through the USB Interface 11 Camera should operate in real time mode no menu command may be displayed REMARKS Before connecting the camera it must be switched on and pass self checks it is recommended to connect the camera to a computer before running the program When the camera operates in video mode it can not use the SD memory card before starting the work in video mode and connecting the camera to the computer remove the KT 160 USER MANUAL 37 card or switch the camera to its internal memory Uflash p 3 10 3 Select Device Type z Please select the thermal image device type kT160 Cancel
24. et select Not this time and click Next Then let the PC search the driver automatically the program will check data storage devices in the search for the driver 32 KT 160 USER MANUAL Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update web site with pour permission Read our privacy policy Can Windows connect to Windows Update to search for software Ol Yes this time only res now and every lime connect a device Click Hest to continue If the driver is not found automatically then select Install from a list or specific location Advanced Found New Hardware Wizard This wizard helps you install software for USB Device 6 If your hardware came with an installation CD a or floppy disk insert it now What do pou want the wizard to do O Install the software automatically Recommended Click Hest to continue Select the folder drive which contains the driver files and click Next to continue KT 160 USER MANUAL 33 Found New Hardware Wizard Please choose your search and installation options 8 Search for the best driver in these locations Use the check boses below to limit or expand the default search which includes local paths and removable media The best diver found will be installed Search removable media
25. floppy CO ROM Include this location in the search s Browse Don t search will choose the driver to install Choose this option to select the device driver from alist Windows does not guarantee that the driver vou choose will be the best match for your hardware The installation begins After reaching the stage shown below select Continue Anyway Found New Hardware Wizard Please wait while the wizard installs the software i SONEL IR Camera Hardware Installation The software wou are installing for this hardware SONEL IR Camera has not passed Windows Logo testing to verify its compatibility with windows AP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway STOP Installation After installation is completed an adequate message is displayed press the Finish 34 KT 160 USER MANUAL Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for g SONEL IR Camera Click Finish to close the wizard zza z Cancel 5 2 Installing Sonel ThermoAnalyze software Before installation it is rec
26. ing KT 160 Camera may operate in either automatic or manual focus mode To change between focus modes shortly press button when the screen is not showing any menu The screen displays the following menu where the function keys have assigned functions according to the bar displayed at the bottom of the screen objects while pressing results in zooming in focusing on closer objects Pressing Py button switches the focus mode into auto focus After pressing the trigger button the camera will remember the settings and exit the function During operation if the focus is not sufficient after using automatic mode point the KT 160 USER MANUAL 9 camera at a target object activate the focus short press button Fa and then by Pig ha pressing button Pa activate the auto focus again or press Fa lt 1 buttons to set the focus manually 3 3 Temperature range Pia When the screen is not showing any menu press and hold button Pa for approximately 1sec Pressing button results in automatic selection of the displayed temperature range maximum and minimum temperatures will be adjusted in the course of the measurement automatically by the device depending on the detected temperature range in the observed area TE Pressing button Pa results in switching into manually selected temperature range Choosing this mode causes switching into the mode for setting the upper limit t
27. ing is displayed Mol pross TES TAO screen will be black Yes After the selection is confirmed the camera switches its image to an external display PAL or NTSC or to the camera screen LCD Select No to return to the selection screen pressing the trigger button 10 exits the menu without saving changes After the selection and approval the camera remains in selected mode PAL LCD NTSC and the user may exit it by pressing the trigger button Until then if the user selects an external monitor and there are problems with displaying the image pressing button and then LF the user may return to displaying the image on the camera screen NOTE It is recommended to switch the camera off before connecting disconnecting an external display 3 9 7 Setting the value for temperature alarm After choosing in Setup the option called Alarm Temp the user may select the temperature above which the camera will emit a warning beep The temperature value may be selected within the range 0 1 250 C 100 C by default 3 10 Setting and viewing files information M When the screen is not showing any menu press button M and the following function selection will be displayed Parameter KT 160 USER MANUAL 25 At any time the user may exit setup menu by pressing the trigger button 10 M After selecting File button 3 a sub menu is opened with options related to the stored images and information Pra
28. ivated in the settings menu parameters see section 2 9 Settings 3 7 Capturing and recording the image with voice annotation The camera displays the image in a continuous manner refreshing it 30 times per second In order to capture an image press the trigger button 10 and this will capture the image and display the menu on the screen KT 160 USER MANUAL 15 Pressing Save Fe button saves the captured image without voice annotation and return to real time mode Pressing Visible Fa button switches the camera screen into the visible image mode captured still image is shown which corresponds to captured infra red image re pressing Pa button or the trigger button 10 switches the screen back to the still infra red image M Pressing Voice Fi button switches into recording mode for voice annotation up to 1 minute Selecting Record button LF starts recording a voice annotation During the recording a time bar located above the command bar displays the current length of the recording in seconds The user may stop recording by pressing the trigger button 10 then the camera returns to Save Voice Visible menu Record without saving a voice annotation 16 KT 160 USER MANUAL Pressing Stop r stops recording the voice annotation Note such action must take place within 60 seconds from the start Recorded annotation may be played Play button Pal thr
29. les stored in the memory To delete some files proceed in accordance with section 3 10 1 The camera may be disconnected from the computer only after closing window KT 160 Manager 6 3 Data Analysis Sonel ThermoAnalyze software supplied with the camera allows the user to perform detailed analysis of the recorded thermal images completed by the report A detailed description is contained in software manual KT 160 USER MANUAL 47 7 Technical specifications Imaging Characteristics THERMAL Detector Type Uncooled FPA microbolometer 160x 120 pixels 25um Spectral Range 8 14um Thermal sensitivity lt 0 1 C at 30 C Field of view 20 6 X 15 5 11mm standard lens focal length Aes Automatic or manual VISUAL Rek WEGA CMOS sensor 1600x1200 pixels true colours mode 24 bit Image Presentation PASA 3 6 TFT LCD display Video Output PAL NTSC Technology Visual and IR blending InfraFusion Temperature range 20 C to 250 C Accuracy 2 C or 2 of reading Emissivity Correction Variable from 0 01 to 1 00 in 0 01 increments Measurement Automatic correction based on distance relative humidity Features atmospheric transmission and external optics Optics Transmission p Automatic based on signals from sensors Correction 48 KT 160 USER MANUAL Laser Locator Classification A1 GalnP semiconductor diode laser Store images Removable SD memory card 2GB Carrier type built in memory 1
30. ng the distance from an object Select Distance and accept it by pressing OK to go to sub menu Setting the distance FA M from an object By pressing the or buttons Bred the user may set the distance between the camera and measured object within the range 0 1 30 meters Changes are confirmed by pressing OK L Setting the distance helps to correct the effects of the medium air pollution haze smoke gases in which the radiation propagates on the accuracy of the measurements The default value is 1 8 m 3 8 5 Setting relative humidity Select Relhum and accept it by pressing OK to go to sub menu Setting ambient re e M relative humidity By pressing the or buttons L fyl the user may set the value of relative humidity depending on environmental conditions in the range O 100 Changes are confirmed by pressing OK LA The default value is 70 3 8 6 Activating the laser locator Laser option allows the user to block or make available the possibility of switching on the laser locator After entering sub menu Switching the laser locator on off the user may Fa Fra activate or block the laser locater by using buttons LR current status of the locator is displayed above the menu bar After selection for an additional information is displayed for two seconds in the upper left corner indicating the current status of the laser By default the laser is turned off
31. ns Access to the camera functions is available by operating buttons 3 located below LCD display 1 and the trigger button 10 2 2 Screen During the operation camera displays infrared image on the screen 1 in the real time mode refreshed 30 times per second On the right side of the screen a temperature range bar is displayed with colours assigned to different temperatures In the centre of the screen the temperature value is continuously displayed along with the selected point of maximum temperature on the observed area KT 160 USER MANUAL T After choosing a function or completing the measurement at the bottom of the screen a menu appears where each option may be performed using one out of the three buttons In the above example the left key F is assigned to zoom out command the middle key M to zoom in command and the right key P is assigned to Autofocus command 8 KT 160 USER MANUAL 3 Camera control and adjustment 3 1 Switching the camera on off In order to switch the camera on press and hold button for more than 3 sec The screen displays welcome logo after which a self check of the camera is carried out the results of consequent tests are displayed on the screen after completing the self check the camera is ready to work and enters the infrared image display mode in real time In order to switch the camera off press and hold button S until the screen goes out 3 2 Focus
32. ommended to close all running programs After inserting the software CD supplied came with the camera into your CD ROM drive when the installation does not start automatically run setup exe Then follow the prompts on the screen NOTE If the user selects a different folder than the default the program will be installed in the folder C Program FilesiSonel ThermoAnalyze During the installation shortcuts will be created on the desktop and in the Start Menu KT 160 USER MANUAL 35 5 3 Configuration of Sonel ThermoAnalyze software NOTE Described below are just some features of Sonel ThermoAnalyze software containing instructions directly related to the infra red filming detailed description of all the features Sonel ThermoAnalyze software may be found the software manual The command Storage menu File is used to define the storage place for recorded movies and images and other parameters related to filming eS ft TOG m ia jk pps ere mH ii ferii gay Farsz LEDE pu FE ee m ger DOM PE wj Fe AMS PER ma Fin Path KUER Caption huge Sv ts TET oy PG Meany AF opm sa raw RE or PG Pia O zy 6 IK EG and open ase td ven ma Dets Pate ae 36 KT 160 USER MANUAL Film Path Sets the directory where the video files will be stored default subdirectory IRVideo folder where the program is installed Capture saved sets the directory for captured images Frame rate det
33. or on a removable SD card After selecting Memory the current status is displayed above the menu bar e g F Memory Uflash The selection is made using buttons LE land pit corresponding to the choice of Uflash or SD Card Selecting SD Card in the absence of the card in the camera s card slot 14 results in displaying the message No SD card Pressing button or the trigger button 10 results the camera to exit the current setting without saving changes Remarks Once SD card is inserted into the slot 14 the camera automatically switches its memory to SD card The camera may use a SD card with a storage capacity up to 2GB Built in Uflash memory 150MB allows the user to store up to 120 images 3 10 4 Help Select Help to display abbreviated reference guide containing basic information related to the camera operation 3 10 5 Information about hardware and software version Select Info to display information about camera s hardware and software version at the top of the screen 3 11 Power supply battery charging The camera is powered by six AA alkaline batteries or AA rechargeable batteries ant it may be also powered using AC adapter KT 160 USER MANUAL 27 Rechargeable batteries are charged without the need to remove them from the camera To start charging rechargeable batteries connect AC adapter to the camera terminal 13 Charging also takes place during operation of the camera
34. ough the speaker 5 or recording process may be repeated button LF Pressing Save Mish saves captured thermal image with the voice annotation REMARKS A voice annotation can be added only BEFORE final saving of the image If the recording time exceeds 60 seconds the recording will be stopped and the annotation will not be saved Pressing the trigger button 10 results in returning to the real time infra red mode without saving the captured image 3 8 Function Settings When the screen is not showing any menu press button L5 and the following function selection will be displayed Er uwa w gt gt Parameter At any time the user may exit function settings menu by pressing the trigger button 10 Fie After selecting Parameter button 1 a submenu is opened to set the parameters of KT 160 USER MANUAL 17 the camera Sai tha Emlash ity ol fe Target Tamb Distance RelH um Laser TB name of the parameter is displayed After accepting OK button LE a sub menu opens allowing the user to adjust given parameter 3 8 1 Setting object emissivity Select Emis and accept it by pressing OK to go to sub menu Setting object Fr IM emissivity By pressing the or Ley LL the emissivity factor may be decreased 18 KT 160 USER MANUAL increased within the range of 0 01 1 00 By pressing the OK Pal the user accepts a new value The default valu
35. ra when it is connected to a computer via USB 2 0 connection registration takes place in the computer memory hard disk this makes the record length limited to the capacity of the computer s hard drive 1 minute of IR video recording is about 25MB IR video stored in a computer may be analysed both during recording and later when read from the disk Operation of the camera in the video mode recording and analysis is done using software supplied with the camera Sonel ThermoAnalyze Infra red filming is possible after installation of the driver supplied on the software CD with the camera 5 1 Installing the camera driver 5 1 1 Hardware requirements Operating System Microsoft Windows 2000 or higher IE5 0 or higher Processor Pentium 4 2 4GHz or more RAM at least 512M 5 1 2 Installation Place the CD with the controller software in your PC s drive and run the program in the folder After the drivers are installed connect the camera to the USB port of your computer The camera must be switched on in the thermal image display mode real time it must not display any menu It is recommended that the SD card is removed from the slot for the time of installation 14 The camera should be detected and installed automatically If this does not happen follow the instructions below The Installation Wizard will start in order to install new hardware when asked about searching appropriate driver in the Intern
36. rature then the occurring chemical processes may reduce their lifetime Ni MH batteries withstand normally 500 1000 charging cycles These batteries reach their maximum capacity after being formatted 2 3 charge discharge cycles The most important factor which influences the lifetime of rechargeable batteries is the level of their discharge The deeper the discharge level of the batteries the shorter their lifetime The memory effect is limited in case of Ni MH batteries These batteries may be charged at any point with no serious consequences However it is recommended to discharge them completely every few cycles During storage of Ni MH batteries they are self discharged at the rate of approximately 30 per month Keeping rechargeable batteries at high temperatures may accelerate this process even 100 In order to prevent excessive discharge of rechargeable batteries after which it would be necessary to format them it is recommended to charge them from time to time even if they are not used Modern fast chargers detect both too low and too high temperature of rechargeable KT 160 USER MANUAL 29 batteries and react to the situation adequately Too low temperature should prevent starting the process of charging which might irreparably damage rechargeable batteries An increase of the temperature of the rechargeable batteries is a signal to stop charging and is a typical phenomenon However charging at a high ambient temperature apart f
37. rd allows the user to save the current view of Path view window as a JPG file in the directory where the captured video images are stored see section 5 3 Menu Measure command Histogram Selecting command Image histogram or Other histogram enables user to display the KT 160 USER MANUAL 43 percentage distribution of temperatures in the real time for the whole thermal video image or for a specific area A UJ s mE 430 C 5 13 8 2147 29 7 377 45 8 Histogram C1 35 490 17 7 21 0 24 3 27 5 30 8 44 1 NOTE A detailed description of commands enabling the user to enter and manipulate analysed areas and description of analysing options for thermal images is presented in Sonel ThermoAnalyzee manual NOTE In the video mode isotherm command is not available Menu Tools command Temperature alarm This function allows the user to activate the alarm when a defined temperature is exceeded Command Alarm Setup sets the temperature which when exceeded activates the alarm After selecting Max the alarm is activated when the temperature exceeds defined temperature After selecting Min the alarm is activated also for temperatures lower than defined in Min field 44 KT 160 USER MANUAL Alarm Temperature value f Max 20 0 a f Min foo C Save pictures Interval 6 SEC Cancel If the user selects box Save Image at a time when the temperature alarm is activa
38. rom reducing batteries lifetime causes an accelerated increase of their temperature and the result is that the batteries are not charged to their full capacity Please note that when the batteries are charged with a fast charger they are charged only to approx 80 of their capacity better results can be achieved by continuing charging the charger enters trickle charging mode and during the next few hours batteries are charged to their full capacity Do not charge or use the batteries in extreme temperatures Extreme temperatures reduce the lifetime of batteries and rechargeable batteries Avoid placing devices powered by rechargeable batteries in very hot environments The nominal working temperature must be absolutely observed 30 KT 160 USER MANUAL 4 Precise temperature measurement Temperature measurement accuracy depends on many factors among others emissivity background temperature the distance from the object relative humidity During the measurements the camera makes the correction based on signals read from the sensors For some situations and materials it may be necessary to manually adjust the parameters Emissivity Infra red measurements base on receiving the infra red radiation emitted by objects The amount of radiation energy is based on two main factors surface temperature and emissivity of the object s surface Default emissivity is 0 98 and it applies to most surfaces The values of emissivity for some materials
39. s the user to adjust the range of displayed temperatures Ante The user can always restore the optimal settings by pressing Cancel button or command Set automatically see above NOTE The adjustment bar appears disappears also after double clicking the video thermogram area Command KT 160 control It allows the user to control the camera using buttons as described in sec 5 4 1 40 KT 160 USER MANUAL Be tone Took fen rn Het MR mette tar EE GEN bh KEM Bl re due mu o len xi ee Putin ee E gig gi Ted db Gobo BS Menu Measure command Temperature unit It allows the user to select the temperature unit Celsius or Fahrenheit 19 Sonel ThermoAnalyze IRYideo1 318 ar lei R Temp Unit Celsius Fahrenheit Measure Tools View Window Help Show MaxTemp Pos Show MinTernp Pos Show Track view Isotherm Hirkrar sara Menu Measure command Show Tmax position and Show Tmin position After selecting each of these command on the video thermogram area the following will be marked with x symbol the point of the highest temperature with symbol the point of the lowest temperature values of these temperatures will be also displayed KT 160 USER MANUAL 41 iela nu MER EG 4 F F PZ EL mj pa R OG a Fi a p 4 i p M nel Tr TE ZE 1 1 F
40. s inserted in the slot 14 and selected in the menu see 3 10 3 then after connecting the camera to PC the content of the SD memory card is seen as another drive installed on the computer Files containing thermograms are located in PICTURE directory Remarks To perform data transmission in the manner described above Sonel ThermoAnalyze software must not be running When connecting the camera to the computer when the SD memory card is selected it is impossible to operate the camera The SD memory card may also be read using an external card reader installed on the computer the card reader is supplied with the camera 6 2 Using the internal Uflash memory Reading data from the internal memory Uflash is possible only using ThermoAnalyze Sonel NOTE Reading data from the internal memory is possible only if the SD memory card is not inserted in the camera s slot 14 and Uflash memory is selected as the default memory see 3 10 3 In order to read copy recorded thermal images run the program and connect the 46 KT 160 USER MANUAL camera camera must be switched on without any menu displayed Then from the top menu File select command KT 160 Camera 172 a4 Sb 7 BE m ne Pop up window will appear enabling the user to download the files all or some of them recorder in Uflash memory to a chosen directory Remarks This function also enables the user to delete all fi
41. ted then the image will be recorded and stored in the same directory where the captured images are stored see 5 3 The recording will be repeated as long as the temperature is exceeded at the intervals specified in Interval field This function is activated by clicking Activate alarm in the menu A 60 Sonel ThermoAnalyze Lutownical iry 318 File Video Help Window Measure Auto Capture re Record Snalysis Data Activated alarm is indicated by mark V The way to change the sound of the temperature alarm is described in the software manual NOTE The command maybe also activated by the key combination Ctrl A 5 4 3 Data record and analysis Command Save data for analysis menu Tools allows the user to export the results of real time analysis of the temperature in the form of a TXT file or a diagram It is possible to display the minimum average and maximum temperature in the form of a dot line or surface diagram in accordance to selected time intervals Detailed description and an example of completed analysis is presented in the software manual KT 160 USER MANUAL 45 6 Data transmission and analysis To perform the transmission of thermal images recorded with the camera PC must have the driver when the internal memory is used and Sonel ThermoAnalyze software installed on its hard disk see section 5 1 5 2 6 1 Reading the external memory SD card When the SD card the i
42. urement and even damage camera s IR detector FPA setting FPA Focal Plane Array in order to ensure accurate temperature measurement the FPA detector was calibrated in different temperature points 7 KT 160 USER MANUAL 5 17 27 37 For example when the camera is turned on at O after some time the temperature of the camera detector will gradually increase and when its internal temperature exceeds 7 an automatic FPA will take place and will last for about 30 sec During the FPA setting the camera will not response to any operations This action will be repeated when the temperature exceeds 17 camera etc NOTE Use only standard and additional accessories listed in Equipment section Using other accessories does not ensure proper operation of the camera and may cause its damage NOTE Due to the continuous development of the device the design of the display and its certain features may be slightly different than presented in this manual NOTE KT 160 Thermal camera has no parts that could be repaired by its user Never attempt to dismantle or modify the camera Opening the unit invalidates the warranty NOTE Laser locator installed in the camera may be dangerous to eyes in case of direct contact DO NOT DIRECTED THE LASER BEAM TOWARDS OTHER PERSONS OR ANIMALS Please note that the laser beam may reflect off shiny surfaces KT 160 USER MANUAL 2 Function buttons and menu 2 1 Layout of butto
43. ximum performance and safety at work but the following precautions must be adhered to at all times in addition to any advised precautions applicable at the relevant work site or work area Keep the camera steady during operation Do not use the camera in temperature exceeding its working and storage temperature ranges Do not direct the camera toward very high intensity radiation sources such as the sun lasers or welding arcs etc Do not expose the camera to dust and moisture When operating the device near water ensure that it is adequately guarded against splashes When the camera is not in use or is to be transported ensure that the unit and its accessories are stored in the protective carry case Do not jam the holes or loudspeaker on the camera body Do not re switch on the camera until 15 seconds later after switching it off Do not throw knock or shake intensely the camera and its components in order to avoid the damage Do not attempt to open the camera body as this action will void the warranty Keep the SD memory card for the exclusive use of the camera During operation if the camera is to be moved from hot cold place to cold hot place e g from inside outside to outside inside of a room switch off the camera and leave it in the new workplace for 20 minutes then turn it on and start normal operation with an accurate temperature measurement Sudden and rapid changes in ambient temperature may cause fault temperature meas
44. yrzw the Pictures You have Saved 3 10 1 Preview of stored images and deleting single images from memory Select Files and accept it by pressing OK to go to the sub menu View stored images where a preview of recorded images is available from the default memory SD card or internal memory see section 3 10 3 Pad ed ec ea ALE IRKCOCU7 Fega IFOGOGTI REg EE v i i Fre M A i To select a saved file is use arrow keys and 1 5 When a file is 26 KT 160 USER MANUAL selected hover press View button Leh to display the picture in full screen mode then another 3 options are available Select Delete to remove a file press Yes to confirm press No to cancel and return to view the image also the user may see the visual image recorded with thermogram Visible or access the voice annotation Voice if recorded Press the trigger button 10 to return to the preview and selection mode for stored images 3 10 2 Deleting all saved images After selecting Del All at the top of the screen a with the following message appears Are you sure you want to delete all images Select Yes to confirm and delete all images stored in internal memory or SD card depending on selected memory see section 3 10 3 Select No to return to File menu 3 10 3 Selecting a memory Memory option allows the user to choose whether the images are stored in internal Uflash memory