Home

Operation and Maintenance Terminal (OMT 1.2) User's Manual for

image

Contents

1. v Moid Value Protocol Type 0 0 Protocol C B System OxDffb WCDMA DEI Stockholml 7 Equipment Number _ 0012 Repeater 0 0 1123 Phone Number OxOffe 467012346 Equipment Factory MobilePartners Ee On Manual 00 Manual 20 00 WCDMA 1969 8 2159 8 MHz 50 0 1441 30 or on 11051503 dBm 0 1504 0B xs 75dB 40dB OSS 45dB oie 4 n eS iso ae Green Read and Write field This field can be used for Search read and Set write Tan Read ONLY field This field can be used for Search read White This field is only stored on your local computer Information is stored when using Save or Set Grey This field can t be changed 6 3 Configuring the Repeater All information are categorized into 4 pages Common Settings page Site Information page Alarm Enable Settings page and Alarm Display page All items can be Enable disable by clicking the box in Front of each parameter You can choose active all items by simply clicking the All box Repeater Parameters Common Settings Site Informations Alarm Enable Settings Alarm Display E I Protocol Type Ox Off Protocol E The buttons listed at the bottom of the window have different fu
2. mm F e oot Be Monitor Phone Number 46 701324567890 Protocol Type ULP Address 902 168 0 Find Device IF local mode please verify the protocol type by clicking Test Protocol button However sometimes the communication network between modem and repeater is temporally not available it s better to go check the sticker tapped on the repeater marked the corresponding Repeater Type or Protocol Type inFormation before conducting the following setup procedure After confirmation choose correct proto col type and click Next button and a following window should appear as shown below OMT Control Configuration View Upgrade Help F x UP E in es Hamnsater Start Add Repeater EX3 Monitor Bri epe Connecting E Eh Reading tify Reading System Type OK 22 Test 2 I UDP Address The number of level slave The index of level 2 slave The number of level 5 slave Create all slaves automatically Click the Test Connect and wait for the OMT to process for a little while After the Test Connect is done click on the Finish At this point the repeater is successfully added and you should be able to see this repeater under the Monitor Browser area When deleting a repeater simply double click on the repeater at the Monitor Browser area that you wish
3. Alarm Enable Settings Alarm Display Moid Value 0300 B 7 Remote alarms To be able to recieve alarms from the repeater via SMS you have to set the Report Phone No 1 field with the phone number to your GSM 3G modem Use international format like 4670987654321 on Settings site Informations Alarm Enable Settings Alam Display All Moid Value Protocol Type OxOffc Protocol C System 0 WCDMA BUE Stockhoimi17 ooo ff Repeater Name Test123 Phone Number E 467012346 Equipment Factory MobilePartners Device Type 0x0003 Band selective repeater ERE 201 11 20 500555 BS will be listed the main window och the OMT software M S Module Comm Failure Di m Solnal23 N Solnal25 FF 2014 11 27 154636 M S Module Comm Failure i Lundll2 501 125 FF 2014 11 27 15 32 58 M S Module Comm Failure S 8 Stockholm117 e Stockholm119 ee 9 Stockholm122 Solnal25 IF phone numbers to managers har been entered OMT manager then SMS will be sent to these num bers in case of an alarm
4. Telia Tele2 UL 1969 8 MHz 1959 90 1979 70 MHz DL 2159 8 MHz 2149 90 2169 70 MHz Telenor UL 1930 2 MHz 1920 30 1940 10 MHz DL 2120 2 MHz 2110 30 2130 10 MHz Tre UL 1950 0 MHz 1940 10 1959 90 MHz DL 2140 0 MHz 2130 10 2149 90 MHz System Type WCDMA Start Channel NO 10750 UL Frequency 19599 DL Frequency 21499 6 3 2 Site Information tab This tab houses the basic repeater site information The information include Product Series Number Firmware Version Model Number BTS ID Property ID Altitude Longitude and Latitude Coverage Area and Remote Communication Mode Common Settings Site Informations Alarm Enable Settings Alarm Display Moid 0005 00 1531 MCM VIA 05006 2014 07 24 Oo 75076107 evo Lo in ET od EE ode 6 3 3 Alarm Enable Settings tab This tab lists all alarm items Please Enable Disable specific alarms by ticking the boxes and click Set make sure to tick the box to the left of the settings you would like to set to the repeater Common Settings Site Informations Alarm Enable Settings Alarm Display Moid Value Enable Enable Enable Enable Enable Enable Enable Enable 6 3 4 Alarm Display tab This window delivers all alarm status received from repeaters Green color indicates a normal status Red color means an alarm has occurred Common Settings Site Informations
5. Terminate connection between computer and repeater or GSM 3G modem Create New Repeater Add a new repeater to the list Rebuild MOID List To retain MOID list This list describes the alarm items Exit Exit and close the OMT program click Stop before exiting the pro gram OMT Control Configuration View Upgrade Help 3 Stop eater ID Equipment Number Remote Connection Create New Repeater Rebuild MOID List 4 3 2 Configuration menu Communication Mode Set Mobile Numbers Modify Password SNMP Service Settings Alarm Sound Settings G3 OMT Control Configuration View Upgrade Communication Mode Set Mobile Numbers lonitor SNMP Service Settings 5 8 Modify Password Alarm Sound Settings A Stockhalmi117 AF Stockholm 19 4 3 3 View menu Toolbar Status Bar Alarm History Search Monitor Parameters Search Repeater Parameters 3 OMT Control Configuration Upgrade be Toolbar Start Status Bar Repeater List fF Solnal 23 AF Lundli2 ed Search Monitoring Parameters Search Repeater Parameters Allows users to configure the communication mode local or remote properly to achieve successful connection Serial Local mode direct to repeater via USB cable SMS Remote SMS control via externa GSM 3G modem Allows users to configure SMS alarms to forwarded to mutiple OMT managers Up to 5 phone numbers can be entered U
6. OMT service Depending on your communication settings it will communi cate over USB Serial or over SMS externa GSM 3G modem Under the Control menu select Create New Repeater item Assign ID number the repeater in the ID box consisting of 1 to 20 characters 0 to 9 digit input A to 2 for letter input Repeater ID is the unique repeater s identification for your mobile network Important The ID has to be unique Each repeater that is being created in the OMT must have dif Ferent ID Enter FF in the Equipment Number box The value FF is for single band repeater like the MPW2100 23 IF the repeater has a 3G modem with a SIM card inside like the MPW2100 23 for remote access enter the SIM card s number into the Repeater Sim Card Number field IF the repeater does not have remote access feature or no SIM card has been installed enter a random number into the Repeater Sim Card Number field Note The Repeater Sim Card Number box cannot be left blank Use international format like 46701234567 Choose correct protocol type For MPW2100 23 choose Protocol Type C Click Next to proceed the next phase IF protocol type is selected manually from the Protocol Type drop down menu the Auto Test Protocol button will shift to Test Protocol button Se next page for picture OMT Control Configuration View Upgrade Help amp F Start Stop Settine Exit
7. PA Switch UL DL Attenuation DL Output Power UL DL Maxi mum Gain value and UL DL Gain The attenuation value 3G WCDMA can be adjusted Directly change the value of UL Att or DL Att item and click Set button and at tenuation will be set into the repeater On Manual On Manual 20 00 MHz WCDMA 1969 8 MHz WCDMA 2159 8 MHz BENE 0144 30 dB 128 dBm 70 dB 75 dB 40 dB 45 dB Setting Center frequencies for repeater Click on any of the Frequency information fields to acces the Frequency settings 2n eater Par an eter Common Settings Site Informations Alarm Enable Settings Alarm Display All Moid Value Protocol Type Ox ffc Protocol C System Ox0ffb WCDMA NUIT Stockholmi7 f Repeater Oxf Test125 Phone Number 467012346 Equipment Factory 0 0 4 MobilePartners Device Type Ox0003 Band selective repeater D1 W ADJ 23 EJ 0 2014 11 22 15701235555 5 a WC On Manus Manus 20 00 Mi fe 2159 8 52 30 o 1051503 128 dBm at ee 754 40 SB When the frequency settings opens you can set the center Frequency for your selected Operator Set Bandwidth to 19 8 MHz fixed in MPW2100 23 but set to 20 or 19 8 MHz to show correct
8. on the toolbar and then access the Function you required 6 1 2 Remote Connection via Wireless Modem When the repeater is equipped with a wireless Modem like MPW2100 23 monitoring and configuring of the repeater parameters can be achieved remotely Open communication configuration window from menu Configuration gt Communication Mode 1 Select the COM port of your AT SMS compatible GSM or 3G modem 2 Set communication Mode as SMS 3 Click Save id OMT Control Configuration View Upgrade Help Start F Communication Mode eat 5 8 Communication Port COM 3 Refresh 4 1 Communication Speed i Communication Serial Port SMS UDP Communication Timeout 180 Cec Detailed explanation of how to set up a remote connection will be discussed in later chapters Note After the Communication Mode has been set according to the connection method Click on the Start on the toolbar and then access the Function you required 6 2 Monitoring and configuring the Repeater 1 Set the correct communication mode first and then press Start to start the service 6 2 1 Set Repeater Parameters To bring up the Repeater Parameters window by doubleclicking on the ID number in the Monitor Browser Mark All and click Search to read configuration data from repeater Common Settings Site Informations Alarm Enable Settings Alarm Display
9. Operation and Maintenance Terminal 1 2 User s Manual for use with MPW2100 23 iX MobilePartners com 1 Outline 1 1 Operation and Maintenance Terminal OMT k be Control Configuration View Upgrade Help amp Stop Setting lonitor Browse _ RepeaterID Equipment Num Repeater Alarm Time Description of Alarms ESL Repeater List an 2014 11 28 09 12 58 M S Module Comm Failure bs Solnal23 2014 11 27 15 46 36 M S Module Comm Failure FS Lundli2 2014 11 27 15 32 58 M S Module Comm Failure 8 Stockholml17 AP Stockholm119 AP Stockholm122 My Solnal25 4 F 010200701324567890FFA13E000302C0040201FF040300011 7 A80043505F53325F5033374739355F524A5F Monitor COM2 Open The OMT is powerful software when it is incorporated with the repeaters it allows the manager to configure control and to monitor the repeater locally or remote The alarms will be sent to the control center This man machine interface used to monitor and operate the repeater system is referred to as the OMT OMT is a window based user friendly interface that provides the operator a means of monitoring and controlling the repeater system in either a local or remote site The OMT provides the real time system monitoring and may be accessed locally through the USB connec tion or remotely via a GSM 3G modem The OMT software is used to configure repeater parameters and tailor the repeater s configuration ac cordi
10. nction Save Button Store the configuration data into the local computer only Set Button Store configuration data into both the local computer and remote repeaters Search Button Retrieve data from remote repeaters and display in local computer Delete Button Delete the repeater marked the Monitor Browser Other Settings Button Extra settings like Frequency band for MPW2100 23 Repeater s configuration can be set back to manufacturer s default value Click on the Default Setting button system will reset all pa rameter back to default value and display a message box to confirm that the setting has succeed 6 3 1 Common Settings tab This page includes General information General inFormation This group of information displays general information to identify re peaters such as Protocol Type System Repeater ID Equipment Num ber Device Type Repeater Name and Repeater SIM card Number and SO 5 Moid Protocol Type Protocol System Dro HEFT WCDMA DED Stockholmi17 Equipment Number eee ff Repeater Name Test123 Phone Number non 467012346 v E jon E ENT I 131 W ADI 23 RJ 2014 11 22 Technical information and config This group of information indicates repeater parameter settings and 2 DL its current performance output power These information includes UL DL
11. ng to the donor BTS The OMT software also provides a log that can monitor and track to the status and messages 2 System Requirements The minimum operating system requirement is Intel Pentium level CPU Minimum 256MB RAM NT 98 2K XP Vista W7 800X600 1024x768 is preferred display Minimum 40GB hard disk 3 Getting Started Install the OMT software from CD or download from mobilepartners com 4 1 Initial Connection to Repeater Before turning on the repeater terminate the BTS and MS port with the 50 ohm dummy loads or in case you don t have dummy loads make sure to use antennas connected far apart Otherwise repeater may be damaged because of self oscillation 4 2 Start up the OMT Start the OMT software The user name is Admin and cant t be changed Leave the password field blank IF a password is needed for users to login due to security concern please assign a password through Configuration Modify Password Note The password is case sensitive 4 3 Main Menu and Functions After starting the main windows users can navigate around the software functions using the tool bar provided at the top of the screen or via the iconic tool bar Each function in the toolbar will be described in the following sections 4 3 1 Control Start Connect to the repeater directly via USB to Mini USB cable or connect to the external GSM 3G modem for SMS communication with mutiple repeaters Stop
12. se internation Format like 46701234567 Allows administrator to set or change the password Set SNMP Trap information to be sent out in case of an alarm Local Alarm sounds on OMT computer Help ID Equipment Number To display or hide the tool bar from screen To display or hide the status bar from screen To display the alarm history of the repeater Open the dialog box for the current monitoring status of the repeater Open display the dialog box for the current repeater settings Help Number Alarm History 4 3 4 Upgrade Upgrade Firmware Upgrade management Firmware in the repeater Upgrade Memmap Upgrade memory configuration file operate by FAE 43 OMT Control Configuration View Help 6 5 Repeater List Be Upgrade Firmware Start Set Upgrade Memmap Repeater ID Equipment Number 5 Adding and Deleting Repeaters 5 1 Adding a Repeater Adding a repeater can be done in local mode via USB cable or in remote mode with externa GSM 3G modem and a SIM card in the repeater You need to have a repeater ready to complete the adding of a new repeater in the OMT When running the OMT for the first time there is no repeater present in the list of left frame In the Monitor Browser Please add a new repeater to the list according to the following steps 1 Make sure the correct Communication Mode has been set Please refer to section 6 for detailed information Click Start to activate
13. to delete After the window is opened click on the Delete and the repeater will be deleted in the OMT 6 Monitoring Configuring Functions 6 1 Connection Type In order to be able to monitor or configure the repeater parameters a connection between the OMT software and repeater has to be established Establishing a connection to the repeater can be achieved via the USB port serial or via the wireless modem SMS 6 1 1 Local Connection via USB Open communication configuration window from menu Configuration Communication Mode 1 Select the COM port of your repeater 2 Set communication Mode as Serial 3 Click Save Gi OMT Control Configuration View Upgrade Help Sta uk Communication Mode Communication Port Refresh 14 11 i Communication Speed juo Communication Mode Serial Port SMS t UDP Communication Timeout 30 Cec IF your COM port is higher than COM16 please reconfigure COM port to a lower number in the computers Device Manager Communication Speed is automatically set to Auto Select the Communication Mode as Serial Port and then click Save to Finish Note Choose the Serial Port For local control USB cable and SMS remote control requires ex terna AT SMS compatible GSM modem or 3G modem connected to the OMT software Note After the Communication Mode has been set according to the connection method Click on the Start