        Dehumidifier User Manual
         Contents
1.                                                                                                                                                                                                                                                                220 240V N  50Hz  sL    ld                                                                         Note  The Dehumidifier must have a good grounding     3  Selection of protective device and cable specification    circuit Rated residual 30 30  breaker Operating current mA    Power cable  mm   3x4  Signal ine  m     Note  The data above is suitable for power lines shorter than 10 meters  For       those longer than 10 meters  the wire diameters must be increased  The    maximum length of signal line is 50 meters     4  Installation instructions and requirements    Dehumidifier must be installed by professional technicians and you as users    cannot do the installation by yourselves  in case that it may cause harm to    others and yourself or damage the machine     A     Installation of machine    1   2     3     Dehumidifier should be installed in a place with good ventilation   The bolt  M 12  must be used to fix the machine body during the  installation  The machine can be fixed on the concrete foundation or  support  with the concrete foundation being firm and the support  being of great strength and anti rust treatment    Please notice that there will be condensate water coming out from  classis during the operation  Conne
2.  wired controller display    ae    Overheat Protection  only available with EC  heating element         Appendix 1  Installation of Heating Element Optional     Warning   The heating element of dehumidifier must be installed and trial  by qualified electrician        A  Heating element   s break down    1  Heating Element  1pc 2   Screws  4pcs          B  Steps  1  Turn off the machine and shut off the power  Use a Phillips screwdriver to  takeoff the 8pcs screws from the side panels  Dismantle the front panel     2  Take off the 2pcs screws on the left side of electric element  take off the    bottom strip        3  Put the heating element on the top of the dehumidifier  make sure the four  holes of heating element in the right position against the four holes of top  panel           6  Open the cover of electric box  and drill the signal cable  amp  power cord    through the holes and pull it to the electric box        8  Connect the power cord of heating element as bellowed chart     Heating Element         Electric Heating Power supply  L     Electric heating overheat protection        POWER  220 240V 50Hz    9  Install the electric box cover and dehumidifier   s front panel back     10  After adding the heating element  please refer to Appendix 2 Advanced  application of inner parameter and reset the code Cl   s value to 1   the default  value of Cl is 0      Appendix 2  Advanced application of inner parameter    Warning     Non professional is not recommended to avoid er
3. Dehumidifier User Manual     For the series of DP40 DP70     Content    I  Please re  d immediately seitin onn aa eiai da adea    MTs  APPC ON cicastas sei E tease A A eames eaten eects 2  Ie Fei unione E T A 2  Eye Techne Paramet Se oss daca asia cosseedacenaoascosseecucme asses  3  V  Overall Dimensioon r e E E EE 4  Vi  nstallat Gud anna nE E A dears 5  Vit    LCD Controller Operation sonrssroikia r a a a 8  VIN  Test ronmin a rien eernialeen ele ane nee 10  A bes 610728 18 E eo Te SPP EET SPP CT Tn SP Cn OP eC 11  Me Reparan a MENAN Ee a a E N E eae 12  XI     General Troubl  eshootnh E serren E EE 13  AM Faaltdis play screen EEA ERR 13  Appendix 1  Installation of Heating Element Optional            eens 14    Appendix 2  Advanced application of inner parametef                  sseeeseeeeseeeeees 17    Please read immediately    Attention     This machine is an ordinary Dehumidifier and can never be used for  regulating other combustible gas and stale air    The main power switch should be installed out of the reach of children to  avoid dangers caused by their playing with the switch    If it 1s necessary to remove the machine shell during repair and    maintenance  please make sure that power has been cut off     Notice for Use    The repair and maintenance must be conducted by qualified and  professional mechanics  The power supply circuit must be in line with the  local standards and please read instructions carefully    Set appropriate humidity levels to create a co
4. X  Precautions    1  The usage should notice that     Ay    By    C     D     Es    Fy  G     H     Please don   t place any object close to the air inlet or outlet which may  block the airflows  Otherwise  the efficiency may be reduced or the  whole operation of the system may even stop    Don   t put hands  sticks or other objects into the air outlet of   Dehumidifier  And don   t dismantle the fan cover  otherwise the fan  running at a high speed may cause harm to you   If any abnormal situation appears  such as strange noises  smell  smoke   electric leakage  etc   electricity should be cut off immediately and the  local dealers should be contacted  Don   t repair the machine by  yourself    The usage or storage of hair gel  paint  oil or other combustible gas or  liquid near the device is forbidden  otherwise there might be fires   Drip washing the machine directly with water is forbidden    Please don   t stand on or lean against the machine    Please don   t use it to preserve the artworks or academic materials or for  other special purposes  otherwise the quality of restored objects might  be reduced    This machine is only for indoor use  Please don   t use it under the    conditions with direct sunlight or wind and rain     2  Safety rules    As     The main power switch should be installed out of the reach of children    to avoid dangers caused by their playing with the switch     ey ee    B  If the electricity fails during the usage  this Dehumidifier will start  
5. automatically after the power restoration  Therefore  please switch off  this machine  Otherwise there might be some accidents    C  Please cut off the main power in thunderstorm weather  or else the  lightning may damage the machine    D  Please cut off the main power and drain water out of the machine if it is    not used for a long time     X  Repair and maintenance    1  Before examining and repairing the Dehumidifier  its power must be cut   off    2  In seasons when this device is not used  please cut off its power and cover   the machine body with plastic cloth so as to avoid the dust    3  When the machine is washed  the domestic neutral detergent or clear water  is recommended and the volatile oil  gasoline  diluent agent or polishing  power for washing 1s forbidden    4  Regularly checking if the bolts has become loose  if the wires have been    worn or if the connections are firm     ee    XI  General Troubleshooting    Cause Handling method  Waiting for power restoration  Switch on the power  Not operating    Check the problem and  Fuse burnt out  replace the fuse  Check the problem and    Leakage circuit breaker   oo  switch on the leakage circuit    being off  breaker    If the problems above cannot be solved  please contact professional  workers and inform them of the product type and details about faults        Attention  Never dismantle the machine and repair it by yourself so  as to avoid any danger     XII  Fault display    Error Code       Protection fault
6. ct the drain port to the drainage  hole in classis and link the drainpipe to enable the smooth    flowing out of condensate water     Electrical wiring installation    1     2   3     4     5     Use the special power supply and the supply voltage should be in  line with the rated voltage of this product    The Dehumidifier must have a good grounding    Wiring must be conducted by professional technicians in accordance  with the standards of circuit diagram    According to related technical standards for electrical equipment  specified by the nation users are located in  the electric leakage  protection device must be well set  the residual operating current  should be less than 30 mA     Power line and signal line arrangement should be tidy and reasonable  without any interference  Given the environmental conditions   environmental temperature  direct sunlight  rainwater  grid voltage     cable length  etc    the sectional area can be increased     C  When the wiring construction is finished  the power can be on if there are    no faults after careful checking     VII  LCD Controller Operation    Heatin    RT g  Ventilation  only available with extra heating element     Dehumidification       Ambient temperature    timer time          Relative humidity    Fan Speed Timer on off    Power on off key Timer on off key             Mode key Wind Speed key    1  Display     a  The screen will display actual relative humidity     and ambient  temperature    C  when the machine is of
7. defrosting    High quality compressor of world famous brands     Convenient installation and easy operation     IV  a Parameters      ModeRef  Ref  DP40 DP70    Capacity in  l h    Air 30  C  Humid 70     Heat Recovered  KW   a    Electric Heating Optional   kw     Rated Power  kW  een en  Power supply 220 240 V 1Ph SOHz    Net Weight   Gross Weight  53 68 70 86   Kgs     1  The rated current with electric heating will be 8 7A for DP40  13A for DP70   1  Dehumidifying capacity refers to the dehumidifying volume when  keeping the relative humidity at 30  C 70       2  Devices of this series can operate normally at the temperature of       5   C 38  C  Effects cannot be guaranteed if not within this range  Please  notice under different working conditions  the technical parameters of the  Dehumidifiers may vary    3  Due to the technical advances  related parameters will have phase  adjustments without additional notices  Please refer to the nameplate for    more information     V  Overall Dimension    ni  ae a i  a                                                                                                                            LOOO                                                                                           i aS fe fete fe fe      o  es  as a  me ee eee ieee    Note  Above is the dimension specification figure and is only for the       reference of professional workers during installation and arrangement  Due  to the continuous improvements  the products 
8. f    b  The screen will display following message when the machine is on   1  Mode  2  Actual relative humidity    and ambient temperature    C      3 Fan speed and timer if set     2  Setting     a  Mode setting  When the machine is on  press M key to switch the mode   Dehumidifying mode     2    Ventilation mode  4     wl    Heating mode  aS  only available with extra heating element               Dehumidifying and Heating     b  Set Humidity  setting range  30    99      In the dehumidifying mode no matter machine   s on or off  every time    you press button    A    or    V      the set humidity will be increased or  decreased by 1   It ll flash for 8 seconds and then display the actual    humidity again     To check the set humidity  press A or V key under dehumidifying  mode    c  Set Fan Speed       oar na nem  When the machine    s on and in ventilation mode     press    SET    to    switch the speed from High speed aMi and low speed al      d  Timer Setting      1  Set timer   When the device is on  the off time can only be set as 1 12H  When the  machine is off  the on time can only be set as 1 12H    Press button           Start the timer setting and change the timer time through  button     A    and    Y         2  Cancel the timer    Press     to have the time value flashing  then press button    Io cancel the    timing and press  lt Q  to exit     e  Keypad lock setting    Press    A   and    W      simultaneously for three seconds  so as to open close    the ke
9. mfortable environment    Dust gauze must be cleaned regularly    Please don   t place objects close to the air inlet or outlet which may block  the airflows    If the electricity fails during the usage  this device will start automatically  after the power restoration    Don   t put hands  sticks or other objects into the air inlet and outlet  Don   t  dismantle the running fans of the dust gauze    If any abnormal situation appears  such as strange noises  smell  smoke   electric leakage  etc   electricity should be cut off immediately and the  local dealers should be contacted  Don   t repair the machine by yourself   The usage or storage of hair gel  paint  oil or other combustible gas or    liquid near the device is forbidden  otherwise there might be fires     II     III     E ae ee R a Se    Application    Economically and efficiently dehumidify  providing you with cozy  environment    Users can decide the machine type by referring to the technical  parameters and under the guidance of professional personnel   Dehumidifiers of this series have been adjusted to the best of its ability  and they can work normally after the wiring and connection of the    drainage tube by professional workers under the standards     Features    Efficient heat exchanger    Sensitive and accurate computer controlling of humidity   Environmental cooling medium R410A    High voltage  low voltage and overheat protection system   Ultra low temperature automatic stop system    Computer automatic 
10. ror by  incorrect operation        Inner parameter   s checking  amp  setting      17    Press button    SET    for three seconds and enter the menu of parameter    checking  amp  setting     Parameters    Code       The smaller 8 displays codes and the bigger 8 displays the relative parameters     A  To check the inner parameters   When machine    s on  press button    Set    for 3 seconds  And then press  button    A    and V    to check the code and relative parameter   B  To set the inner parameters   When machine    s off  press button    Set    for 3 seconds  Press    A     and     V    to check each code  amp  parameter  press    Set    and the code will    flash  you can press    A    and    Y    to reset the parameter value  After  press       Set    to confirm  And press    T  ar O to exit     The parameter table is as follows     Parameter Se  Parameter specification Default value  meaning    0 no I yes a    Measured  value    C2 Coil temperature  20  C 99  C    5    5        18       compensation                      Defrosting cycle 20Min 90Min    Defrosting starting 10  C  10  C  temperature  6 Defrosting closing 0C 15  C  temperature  Maximum  defrosting 2Min 12Min  time    O reaching the set value  Working state and the fan stops     of draught 1 reaching the set value  fan and the fan operates  with low wind    temperature value  temperature value  value  degree          Ox    Version  H64 20130719    
11. will have phase adjustments  without additional notices     VI  Installation Guide    1  Position     1  The distance of dehumidifier must be over 2 meters from the swimming  pool     Ambient   Floor Standing Ambient_Wall Mounted       l  i TT      4  i     TI   ia Lt ami   LP 1 i  4  ae rr   a LL   p  al     l   l      I       l    rer  Cold Humid air           _  late   Ld  Cold Humid air                           2  Make two holes in a strong wall and knock two explosion screws  ofp 12mm     3  Hang the machine from the screws firmly through two circular holes on  the back of the machine     4  Connect the drainpipe     5  Connect the signal lines and power line in accordance with the connection                                                       ani  AN  Lo ae    Z i l                                                                                                                                      Qw                                                 A  signal line   B  power line     C  water outlet    Note  The figure above is an example and the machine installation and    arrangement ts only for reference     2  Electrical wiring diagram                                                                                                                                                                                                             Breaker fuse   Customer prepare     Earthing P AN Power Cord  Power Supply L                                                        
12. ypad lock    f  Set Heating   only available with extra heating element  the setting  range is from 18  C to 32  C    NA  Under heating mode 7 pS every time you press A or V  the set  temperature can be increased or decreased by 1   C   To check the set temperature  press A or V and it   ll display the set    temperature     g  Set Humidity amp  Heating   only available with extra heating         wiles       Under mode dehumidifying and heating   j  1S  press A or V to reach    the set humidity  amp  temperature  Press          to switch on humidity and    temperature     VIII  Test running  1  Checking before usage    A  Check whether the whole machine is place on the ground vertically and  be connected with drainpipes   B  Check whether the electrical wiring has been connected in accordance  with the electrical wiring diagram and whether the earth wire has been  linked reliably    C  Check whether the power of host machine has been cut off    D  Check whether the set humidity is appropriate    E  Ensure the air inlet and outlet of the Dehumidifier haven   t been blocked     2  Test run     10     Ay    Users should first switch on the power     B  To protect the dehumidifier  the device has the start delay function     Every time when the machine is switched on  the draught fan starts first    and then the compressors operate automatically one minute later     C  After the dehumidifier start  check whether there is any strange noise    along with the machine operation     I
    