1. OPERATING TIPS The following recommendations will help obtain the best performance from the oscilloscope 1 Always use the probe ground clips for best results attached to a circuit ground point near the point of measurement Do not rely solely on an external ground wire in lieu of the probe ground clips as undesired signals may be introduced 2 Avoid the following operating conditions a Direct sunlight b High temperature and humidity c Mechanical vibration d Electrical noise and strong magnetic fields such as near large motors power supplies transformers etc 3 Occasionally check trace rotation probe compensation and calibration accuracy of the oscilloscope using the procedures found in the MAINTENANCE section of this manual 4 Terminate the output of a signal generator into its characteristic impedance to minimize ringing especially if the signal has fast edges such as square waves or pulses For example the typical 50 W output of a square wave generator should be terminated into an external 50 W terminating load and connected to the oscilloscope with 50 W coaxial cable 5 Probe compensation adjustment matches the prob eto the input of the scope For best results compensation should be adjusted initially then the same probe always used with the same channel Probe compensation should be readjusted when a probe from a different oscilloscope is used INITIAL STARTING PROCEDURE Until you familiarize yo
2. ting triggering and sweep time controls to obtain a stable display showing the desired number of waveforms DUAL TRACE DISPLAY In observing simultaneous waveforms on channel 1 and 2 the waveforms are usually related in frequency or one of the waveforms is synchronized to the other although the basic frequencies are different To observe two such related waveforms simultaneously perform the following 1 Connect probes to both the CH 1 X and CH 2 Y input jacks 2 Connect the ground clips of the probes to the chassis or common of the equipment under test Connect the tips of the probes to the two points in the circuit where waveforms are to be measured Aj
3. urself with the use of all controls the settings given here can be used as a reference point to obtain a trace on the CRT in preparation for waveform observation 1 Set these controls as follows On both models VERTical MODE to CH1 CH1 AC GND DC to GND Trigger COUPLING to AUTO OPERATING INSTRUCTIONS Trigger SOURCE to CHI All POSition controls and INTENSITY control centered pointers facing up Main Time Base control to 1 mS div 2 Press the red POWER pushbutton 3 A trace should appear on the CRT Adjust the trace brightness with the INTENTSITY control and the trace sharpness with the FOCUS countrol SINGLE TRACE DISPLAY Either channel 1 or channel 2 may be used for single trace operation To observe a waveform on channel 1 1 Perform the steps of the Initial Starting Procedure 2 Connect the probe to the CH 1 X input jack 3 Connect the probe ground clip to the chassis or common of the equipment under test Connect the probe tip to the point of measurement 4 Move the CH1 AC GND DC switch out of the GND position to either DC or AC 5 Ifno waveforms appear increase the sensitivity by turning the CH 1 VOLTS DIV control clockwise to a position that gives 2 to 6 divisions vertical deflection 6 Position the waveform vertically as desired using the CH1 POSition control 7 The display on the CRT may be unsynchronized Refer to the Triggering paragraphs in this section for procedures on set
Download Pdf Manuals
Related Search
Related Contents
Manual Digimini - trondigital.com.br USER GUIDE Dell PowerEdge R720xd Update Manual Manuel d`utilisation User Manual - ADFWeb.com NAD S500i User Guide Manual Gomoku Eurofase 23188-037 Installation Guide PDF 施工要領書 PX10 (JA), 1.6 MB Sinus 421 collection_BA_040820 Copyright © All rights reserved.
Failed to retrieve file