1. Revision 0240 ANTEGRIO J750 Test System Probe Purge Solution Kit nwa Installation Manual Overview The J750 Probe Purge Solution Kit comes ready to assemble to the customer s Probe Interface Board PIB The kit consists of e J750 Tester Side Purge Cap e Prober Side Purge Cap e Quick Star Push Pull Standard Straight Connector e Quick Star Push Pull L Connector e 6mm tubing 22 long e 6 32 x long flat head screws quantity 2 Installation of the kit helps reduce condensation build up on the PIB when wafer testing is being performed while the prober is running at cold temperatures Figure 1 shows a drawing of the kit components as assembled to the PIB Prober Side Purge Cap P N 534 357 00 6 32 x 3 4 Long Flat Head Screw P N 470 169 20 Probe Interface Board 2 places A J750 Tester Side Quick Star Push Pull Standard Purge Cap Straight Connector P N 534 356 00 P N 479 469 00 F 000982 Note 6mm tubing not shown Figure 1 J750 Probe Purge Solution Kit 1 Document Number 552 360 72 Revision 0240 INTEGRI J750 Test System Probe Purge Solution Kit MERA Installation Manual Installation Overview The Installation section provides information and procedures for the following e Unpacking the Probe Purge Solution Kit e Installing the Probe Purge Solution Kit Unpacking the Probe Purge Solution Kit The kit is shipped in a single carton Prior to starting installation open the carto
2. A li Document Number 552 360 72 Revision 0240 ANTEGRIO J750 Test System Probe Purge Solution Kit ae Installation Manual About This Document This manual describes how to install the J750 Probe Purge Solution Kit Teradyne Part Number IT 901 13 to the customer s Probe Interface Board PIB All instructions assume that both the J750 tester and the prober are installed and fully operational This manual is intended for trained maintenance personnel The local Teradyne Service office can assist with any additional questions you may have about the J750 Test System or this kit We welcome any comments or feedback you have about this manual the purge kit or the J750 Test System Please send feedback to J750Support teradyne com For your convenience we have also included a Manual Comment Form at the end of this document Viewing This Document Online When viewing this document online you may click any hyperlink cross reference or page number to jump to that topic Additional Documentation The following documents may provide additional information when using this document e J750 512 Pin Test System Service Reference Manual Teradyne Document Number 552 360 33 e J750 1024 Pin Test System Service Reference Manual Teradyne Document Number 552 360 34 iii Document Number 552 360 72 Revision 0240 ANTEGRIO J750 Test System Probe Purge Solution Kit TERA Installation Manual Revision History Description of Re
3. TEA J750 Test Systems lt INTEGRE gt J 50 Test System Probe Purge Solution Kit Installation Manual Document Number 552 360 772 Revision 0240 ANTEGRIO J750 Test System Probe Purge Solution Kit y ERADY NE Installation Manual Limited Production Rights This document may be reproduced by a Teradyne customer solely for internal use by the customer s employees whose responsibilities include Teradyne equipment Any copy of this document or portions thereof must contain the copyright and proprietary rights notice as stated on the original document The material in this document is subject to change without notice Teradyne s liability for any errors in this document is limited to the correction of errors Teradyne WILL NOT BE RESPONSIBLE IN ANY EVENT FOR ERRORS IN THIS DOCUMENT OR FOR ANY DAMAGES INCIDENTAL OR CONSEQUENTIAL INCLUDING MONETARY LOSSES that might arise from the use of this document or the information in it Restricted Rights Legend Use duplication or disclosure by the Government is subject to restrictions set forth in subdivision b 3 ii of the Rights in Technical Data and Computer Software clause of DFARS 52 227 7013 Credits and Trademarks TERADYNE logo is a registered trademark of Teradyne Inc Other product names mentioned in this document may be trademarks of their respective companies and they are mentioned here for identification purposes only Copyright O Teradyne Inc 2002 Printed in the U S
4. e Purge Solution Kit y ERADY NE Installation Manual Personal Notes 9 Document Number 552 360 72 Revision 0240 ANTEGRIO J750 Test System Probe Purge Solution Kit MERA Installation Manual Manual Comment Form We appreciate your feedback Your comments are a valuable source of information for continuous improvement in our documentation effort Please return this form together with a copy of the pages of concern from the manual marked with your comments to the address at the end of this form Manual Name Document number Company Job title 1 Briefly in the space below how would you describe this manual 2 How do you use this manual ___lread it from beginning to end ___l only read the sections that pertain to my immediate needs __ only read the sections that pertain to my job __ l use this manual for training purposes __ use this manual for reference purposes 3 When you need to find information in this manual where is the first place that you look __ Table of Contents __ Thumb through the pages until find what am looking for 4 How easily can you find information in this manual 1 2 3 4 5 Not easily Very easy 5 How clear is the information in this manual 1 2 3 4 5 Not clear Very clear continued on next page 10 Document Number 552 360 72 Revision 0240 ANTEGRIO J750 Test System Probe Purge Solution Kit E ERADY NE Installation Manual 6 When you actually try instructions in th
5. is manual how easily can you follow them 1 2 3 4 5 Not easily Very easy 7 How well did you understand the product before reading this manual 1 2 3 4 5 Not at all Very well 8 After 1 2 3 4 5 Not at all Very well 9 Was all of the information you needed included in this manual _ Yes _ No If not what was missing 10 The best aspect of this manual is 11 If you could change one aspect of this manual what would it be Other comments Return to Teradyne Inc 9 Crosby Drive Bedford MA 01730 1401 USA Attn Product Support Department FAX 781 275 2824 Email ITD PSG teradyne com 11 Document Number 552 360 72 Revision 0240
6. lution Kit ERA Installation Manual 6 Connect the piece of 6mm tubing Teradyne Part Number 479 018 02 from the kit into the end of the Quick Star Push Pull Standard Straight Connector Figure 6 shows the tubing connected to the connector F 000990 Figure 6 Tubing connected to quick star straight connector 7 Mount the PIB onto the DIB fixture of the tester then connect a 6mm air supply tube from the prober to the end of the L Connector The J750 Probe Purge Solution Kit is now fully assembled and ready for use Note Ensure that the pressure of the air supply flowing through the Purge solution does not exceed 30 psi Standard operating pressure for the Probe Purge Solution Kit is 25 30 psi 6 Document Number 552 360 72 Revision 0240 ANTEGRIO J750 Test System Probe Purge Solution Kit nas Installation Manual Reference Information Bill of Materials BOM Part Description Quantity Number 534 357 00 Prober Side Purge Cap Z o o 1 479 018 02 6mm tubing 22 long 470 169 20 Screw flat socket head no 6 32 x 3 4 inch long 479 479 00 Quick Star Push Pull L Connector 7 Document Number 552 360 72 Revision 0240 ANTEGRIO J750 Test System Probe Purge Solution Kit TERA Installation Manual Assembly Drawings The Assembly Drawing section of this manual provides the following drawings e N A 8 Document Number 552 360 72 Revision 0240 INTEGRO J750 Test System Prob
7. n and ensure that the following items are present e J750 Tester Side Purge Cap Teradyne Part Number 534 356 00 e Prober Side Purge Cap Teradyne Part Number 534 357 00 e Quick Star Push Pull Standard Straight Connector Teradyne Part Number 479 469 00 e Quick Star Push Pull L Connector Teradyne Part Number 479 479 00 e 6mm tubing 22 long Teradyne Part Number 479 018 02 e 6 32 x long flat head screws quantity 2 Teradyne Part Number 470 169 20 Installing the Probe Purge Solution Kit This section of the manual describes the procedures for installing the J750 Probe Purge Solution Kit to the PIB Note These instructions assume that both the tester and prober are installed and are fully operational Do not attempt to install the kit if this is not the case The following tools are required to install the kit e No 2 phillips screwdriver e 12mm open end wrench e 5 64 hex wrench Perform the following steps to install the kit to the PIB Preparing the Tester Prior to installing the J750 Probe Purge Solution Kit the J750 tester must be prepared as follows Caution Always wear a tested grounding strap while working on the J750 tester 1 Ensure that the tester is fully undocked and a sufficient distance from the mating equipment 2 Document Number 552 360 72 Revision 0240 ANTEGRIO J750 Test System Probe Purge Solution Kit y ERADY NE Installation Manual 2 Position the tester so that the DIB mounti
8. nd secure using the two 2 6 32 x 34 long flat head screws provided with the kit Tighten the screws using the 5 64 hex wrench for this purpose Figure 3 shows the caps assembled to the PIB Prober Side Purge Cap F wr _re A EE Probe Interface Board PIB Y Quick Star Push Pull a J750 Tester Side Purge Cap Connector Standard Straight F 000987 Figure 3 Purge caps assembled to PIB 3 Assemble the Quick Star Push Pull L Connector Teradyne Part Number 479 479 00 from the kit onto the free end of the 6mm piece of tubing 4 Lay the piece of tubing on top of the tester so that the end with the connector hangs over the side of the tester and the other end of the tubing is in the center of the Air Flow Shield Figure 4 shows the tubing on the tester 4 Document Number 552 360 72 Revision 0240 SINTEGRA gt J750 Test System Probe Purge Solution Kit ERA Installation Manual F 000988 Figure 4 6mm tubing on the tester 5 Replace the DIB cover onto the tester so that the tubing fits under one of the notches in the cover and secure using the six 6 8 32 x 3 8 long phillips head screws previously removed Tighten the screws using the no 2 phillips screwdriver Figure 5 shows the tubing properly positioned under the cover F 000989 Figure 5 Tubing under DIB cover 5 Document Number 552 360 72 Revision 0240 SINTEGRA gt J750 Test System Probe Purge So
9. ng surface faces up Caution Always ground the Customer PIB when installing or removing it from the DIB fixture on the tester 3 Properly ground the Customer PIB as outlined in the Grounding Calibration and Customer DIBs section of the Maintenance chapter of the J750 512 Pin Test System Service Reference Manual or the J750 1024 Pin Test System Service Reference Manual as appropriate 4 Push the red Power Off switch on the front of the J750 tester to turn off power Place the DIB vacuum switch on the tester to the UNLOCK off position 6 Remove the Customer PIB from the tester then remove the ground connection Place the PIB onto a proper work surface 7 Remove the six 6 8 32 x 3 8 long phillips head screws from the DIB cover using the no 2 phillips screwdriver then remove the cover from the tester Installing the Probe Purge Kit 1 Screw the Quick Star Push Pull Standard Straight Connector into the J750 Tester Side Purge Cap Tighten the connector finger tight then turn it an additional half turn using the 12mm open end wrench Figure 2 shows the connector assembled to the cap Quick Star Push Pull Standard Straight Connector J750 Tester Side Purge Cap F 000986 Figure 2 J750 probe purge kit assembly 3 Document Number 552 360 72 Revision 0240 ANTEGRIO J750 Test System Probe Purge Solution Kit BER ALY NE Installation Manual 2 Assemble the two 2 Purge Caps to the Probe Interface Board PIB a
10. vision 0240 Initial Release A IV Document Number 552 360 72 Revision 0240 ANTEGRIO J750 Test System Probe Purge Solution Kit Installation Manual Table of Contents 0 Y 1 ATA aa MSto OM OV OTIC UU A Unpacking the Probe Purge Solution Kit Installing the Probe Purge Solution Kit Preparing the Tester naciste titres Installing the Probe Purge Kit cccssssssseeesesessseeeseesseeesseeenseees Reference INfOrmatiOn c cceccsccscencsncsccencscescesceneenesnesnees Bill of Materials BOM occocccocconcconconcconconcconcnnnconrnanconnnanenannns Assembly Drawings serre Personal NOTES ars B ERADY NE Document Number 552 360 72 Revision 0240 ANTEGRIO J750 Test System Probe Purge Solution Kit VERAS Installation Manual List of Figures Figure 1 J750 Probe Purge Solution Kit cccssseesseseeseeseeceseeeeeneesensessenseseeneeses 1 Figure 2 J750 probe purge kit assembly ri 3 Figure 3 Purge caps assembled to PIB 1 1rrsrrrrneireiiiiiiiii 4 Figure 4 6mm tubing on the tester 1 11r1srrsrrrnire nari 5 Figure 5 Tubing under DIB cover 11ss1rsirisiiii iii 5 Figure 6 Tubing connected to quick star straight connector 6 vi Document Number 552 360 72

Download Pdf Manuals

image

Related Search

Related Contents

Avaya Business Element Manager BCM Rls 6.0 User's Manual  OPERATING MANUAL GUIDE D`UTILISATION ASSEMBLY  technical manual  Global Map Raster Devel- opment (GMRD) Tool User`s Manual  LG MV-1310W User's Manual  Tubing Analysis System TAS User Manual  Amadeus Ticket Changer (ATC)  取扱説明書 - Seesaa Wiki(ウィキ)  CREPES MOELLEUSES VANILLEES 10CM SURGELEES 15X12  Siemens X005 User's Manual  