1. 4 Function Front Side Back Side EF Kane l 34 5 6 7 ZONE setting Scene 1 Scene 6 Number key 3 WI Dom 16 Two line system signal por DIP switch 1 5 System Diagram Two line signal communication non polarity To EDX system Module Dimmer Pack Control Panel KODE ECP 106T Two line signal communication non polarity Module Dimmer Pack Control Panel KID ECP 106T Two line signal communication non polarity f Ti Module Dimmer Pack Control Panel MCE ECP 1QG6T 3 Lite Puter ECP 106T EUM B Bi Lite Puter ISO 9001 CERTIFIED www liteputer com tw Chapter 2 Operation 2 1 Zone Setting Before use please set each control panel s zone No because one ECP 106T can control 1 8 zone at the same time ECP 106T has two methods to set the zone on the panel and DIP switch DIP 10 up ON set zone by DIP switch DIP 10 down OFF set zone on the panel ECP 106T has two control modes single zone mode and multi zone mode DIP 9 up ON ECP 106T in multi zone mode DIP 9 down OFF ECP 106T in single zone mode 2 1 1 Zone Setting by DIP switch Dismount the front cover of ECP 106T you can see the DIP switch as below ON On SAB odaddadaasan m
2. 86472727 Website www liteputer com tw E mail sales liteputer com tw Shanghai Factory Lite Puter Technology Shanghai Co Ltd Address Building B5 No 298 Lane 3509 Hongmei S Road Shanghai China Zip Code 201108 Tel 86 21 54408210 Fax 86 21 64978079 Shanghai Sales Center Address Room 701 Building Gem No 487 Tianlin Road Shanghai China Zip Code 201103 Tel 86 21 33674316 33674850 Fax 86 21 33674013 Website www liteputer com cn E mail sales_china liteputer com tw 10 Lite Puter ECP 106T EUM B
3. a Lite Puter ISO 9001 CERTIFIED www liteputer com tw ECP 106T Environmental Lighting Control System Control Panel User Manual Lite Puter Enterprise Co Ltd Website www liteputer com tw Email salesQliteputer com tw Lite Puter ECP 106T EUM B Bi Lite Puter ISO 9001 CERTIFIED www liteputer com tw Index CHAPTER 1 INTRODUCTION ccecececececececeeeeeecenecececeneeeeeneeeaeeeaeauauaueneueaeanaeaeeaeaeaeaeauaeeeneennenenenanenaens 2 1 1 ys dette AA AA AA taser lie sede Baht ane neg agra AA AA AA ja ka kt r si kra l ti kb s a kep d t d 2 1 2 SPECIFICATION 2 ccccececececececececcccecauacaececeaeneneneneneneneneneueneueueuetecaueneuenenenecsteuececsuscscacacecenecenas 2 1 3 fua ME MAAMUZI UNAAMUA Me ANE POOR FO aed saa SIRI Fe MANAIKI EP 2 1 4 O AAA PE PIE 3 1 5 AA AAA AAA AAA 3 CHAPTER 2 OPERATION wwssunsunsunzunuununzan auza anana aaa aaa anana aa aaaaaaasaaasosasssosssossessssosossenaseneuonous 4 2 1 EN tt Or A OO OO A AAA 4 2 1 1 Zone Seting Dy DIP SWITCH si tay ne si on e oi a l a al aa 4 2 1 2 Zone Setting on the panel eee ccccssseecceeseeeceeeeceeceeeeeecsegeeecseseeessgeeecseueesseaseesssageees 5 2 2 MN AAA AAA AAA 6 2 3 Do AAA AAA 6 2 4 FINE ADJUST DIMMING LEVEL ccccececececececececececacacacaeaeaeaeaeaeaeuenenenenenenenenenstecsueneneaenenenenens 7 2 5 KEY LOCK UNLOCK FUNCTION ccccccecececececececccececcacccaeaeaeneaenenenenenenenenenenetecececs
4. ai me DIP 10 zone setting by DIP 23456763910 switch or panel DIP 1 8 DIP 9 single zone or multi zone setting Zone No 1 Multi zone mode STEP 1 Turning DIP 10 up ON and DIP 9 up ON means ECP 106T s zone is set by the DIP switch and it is on the multi zone mode STEP 2 Use DIP 1 to 8 to set zone no For example set ECP 106T control zone 1 5 and 8 Turn DIP 10 up ON and DIP 9 up ON then turn DIP 1 DIP 5 and DIP 8 up ON 2 Single zone mode STEP 1 Turning DIP 10 up ON and DIP 9 down OFF means ECP 106T s zone is set by the DIP switch and it is on the single zone mode 4 Lite Puter ECP 106T EUM B Bi Lite Puter ISO 9001 CERTIFIED www liteputer com tw STEP 2 Use DIP 1 to 8 to set zone no from 1 to 255 in binary syetem For example set ECP 106T control zone 25 Turn DIP 10 up ON and DIP 9 down OFF then turn DIP 1 DIP 4 and DIP 5 up ON 2 1 2 Zone Setting on the panel 1 4 2 5 3 6 1 Multi zone mode STEP 1 Turning IP 10 down OFF and DIP 9 up ON means ECP 106T s zone is set by the panel and it is on the multi zone mode STEP 2 Poke and hold ZONE then the LED on OFF key will blink press 1 6 to set zone no from 1to 6 then release ZONE to save the setting For example Set ECP 106T control zone 2 5 and 6 Turn DIP 10 down OFF and DIP 9 up ON Poke and hold ZONE then the LED on OFF key will blink press 2 5 and 6 onthe panel then
5. emote controller to recall the scenes and adjust dimming level 2 7 Meaning of LED Notice LED on 1 6 is green and LED on OFF is red When releasing ZONE hole LED on 1 6 key glow green means the corresponding scene s call out When poking and holding ZONE hole LED on OFF blink means ECP 106T in multi zone mode LED on OFF is extinguished means ECP 106T in single zone mode LED on OFF blink quickly means ECP 106T s zone is set by the DIP switch For example LED on OFF blinkand LED on 2 8 3 glow green means ECP 106T in multi zone mode and control zone 2 and 3 LED on OFF isextinguished and LED on 2 8 3 glow green means ECP 106Tin single zone mode and control zone 6 7 Lite Puter ECP 106T EUM B Bi Lite Puter ISO 9001 CERTIFIED www liteputer com tw Appendix Binary Zone Setting Guide ZONE 8bitDIP ZONE 8bitDIP ZONE 8 bit DIP 12345678 12345678 12345678 727710000000 772701000000 3 11000000 477720010000 s 10100000 6 01100000 T 11100000 8 00010000 9 10010000 40 01010000 41 11010000 42 00110000 as 10110000 14 o1t0000 45 11110000 ae 00001000 17 10001000 18 01001000 197711001000 20 00101000 21 10101000 22 onoo 772517010000 24 00011000 10011000 01011000 11011000 as oomoo 29 10111000 30 01111000 aa moo 32 00000100 33 10000100 a4 7701000100 35 11000100 36 00100100 237771010100 38 or100t00 39 11100100 m
6. s the ID NO setting is done Notice When several ECP 106T are connected together each one must have a different ID NO otherwise the LED on the number keys that stands for the repeated ID no will blink to remind the ID No conflict 2 3 Scene Recall Press 1 6 on the panel to recall corresponding scenes For example press 1 to recall the SC1 and the LED on the key will glow If SC1 SC6 is preset in FADE mode press 1 6 once and the scenes will fade in quick press 1 6 twice and the scenes will be directly called out 6 Lite Puter ECP 106T EUM B Bi Lite Puter ISO 9001 CERTIFIED www liteputer com tw 2 4 Fine Adjust Dimming Level Press V or A to fine adjust all channel s dimming level in a scene 2 5 Key Lock Unlock Function Poke and hold ZONE J hole then press OFF at the same time to lock or unlock the keys Notice This function can remember last key lock status before the power off 2 6 IR Remote Control ECP 106T can receive IR single from r
7. the LED on these 3 keys will glow After setting release ZONE to save it Notice when ECP 106T s zone is set on the panel in multi zone mode it can control up to 6 zones when ECP 106T s zone is set by the DIP switch in multi zone mode it can control up to 8 zones 5 Lite Puter ECP 106T EUM B Bi Lite Puter ISO 9001 CERTIFIED www liteputer com tw 2 Single zone mode STEP 1 Turning IP 10 down OFF and DIP 9 down OFF means ECP 106T s zone is set by the panel and it is on the single zone mode STEP 2 Poke and hold ZONE then the LED on OFF key will blink press 1 6 to set zone no from ito 63 then release ZONE to save the setting Using 1 6 number key in binary system to set the zone no from 1 to 63 For example Set ECP 106T control zone 5 Turn DIP 10 down OFF and DIP 9 down OFF Poke and hold ZONE then the LED on OFF key will blink press 1 and 3 on the panel then the LED on these 2 keys will glow After setting release ZONE to save it Notice when ECP 106T s zone is set on the panel in single zone mode it can control up to 63 zones when ECP 106T s zone is set by the DIP switch in single zone mode it can control up to 255 zones 2 2 ID NO Setting Poke and hold ZONE land A Jtill LED on OFF blinks quickly release ZONE and A then use 1 6 key in binary system to set the ID No from 1 to 63 The LED on the 1 6 keys will glow when they re pressed and it mean
8. uenenenenenenenens 7 2 6 MMPI ce cece ce cecececncncacncacncececscscscucscecacacacacacacatauatauauaeaeacacacatatatataeaeaeaeaenes 7 2 7 ii e e n Aaaa wanauzwa nw nwa Kwakua Kanana nwa Ku waku nwa A wna 7 APPENDIX BINARY ZONE SETTING GUIDE 0000 atab twaka annan nna nana nana nana nana ne nenenasasasasososonosananannn 8 GUARANTEE ssssansunzunzununuu kana kaka kanna aaa aa aa aaa aaa aa anana nana aa aaaaaaaaaaaanananaaanenenenenesenasnsaannnnn 9 1 Lite Puter ECP 106T EUM B a Lite Puter ISO 9001 CERTIFIED www liteputer com tw Chapter 1 Introduction 1 1 Feature e Two line system control panel Non polarized connection to save wiring work Device ID No setting and ID conflict reminder e In multi zone mode one ECP 106T can control 1 8 zone at the same time in single zone mode one ECP 106T can control up to 255 zone Press 1 6 number key on control panel to directly recall 6 scenes Press V or A to fine adjust all channel s dimming level in a scene e 256 level dimming solutions enable more complicated lighting change e Key Lock unlock function e IR remote control 1 2 Specification e Power Supply DC 24V supply by the bus current 20mA static state Protocol two line system e Signal Connector 2 pin green terminal Dimension 86 W x 86 H x36 D mm e Weight 90g 1 3 Dimension 2 Lite Puter ECP 106T EUM B a Lite Puter ISO 9001 CERTIFIED www liteputer com tw 1
9. w 00010100 a 10010100 42 01010100 7 a mooo 44 00110100 as 10110100 a omoro 47 11110100 a8 00001100 as 7710001100 775010100100 s1 11001100 252700101100 s3 10101100 s4 01101100 ss momoo se ooo1100 57 10011100 se o101t100 sa 10011100 60 00111100 et ommo o ess man X 0 stands for DIP down OFF 1 stands for DIP up ON 8 Lite Puter ECP 106T EUM B Bi Lite Puter ISO 9001 CERTIFIED www liteputer com tw Guarantee Lite Puter promises to fulfill the following acceptances 1 Lite Puter is only responsible for ECP 106T itself 2 Lite Puter guarantees to keep Lite Puter s fault products caused by techniques materials and any other logical reasons in good repair for free within a year since the distributing date 3 We do not offer door visiting service If the trouble appears in Lite Puter s products please deliver the equipment to local distributors or Taipei headquarter Special Statement Any fault caused by false usage imprudence collision or inadequate installation or force majeure factors are not in Lite Puter s service Revision Record PB Add 2 7 Issued on March 2010 9 Lite Puter ECP 106T EUM B Bi Lite Puter ISO 9001 CERTIFIED www liteputer com tw Lite Puter World Headquarter Lite Puter Enterprise Co Ltd Address 9F No 196 Sec 3 Da Tung Rd Shijr City Taipei Taiwan Zip Code 22103 Tel 886 2 86472828 Fax 886 2