Home

SAS to SAS/SATA JBOD Subsystem User Manual

image

Contents

1. AS In Port Use to connect to SAS HBA or to RAID subsystem s SAS Expansion Port SAS Expansion Port Use to connect to the SAS In Port of another j JBOD subsystem Use to upgrade the firmware of the J BOD controller Connect the RJ 11 to DB9 serial cable to your system s serial port g H Tr Q Ip E 0 Link LED Green I ndicates expander has connected or linked Activity LED Blinking I ndicates the expander is busy and being Blue accessed 1 5 Power Supply Fan Module PSFM The JBOD subsystem contains two 500W Power Supply Fan Modules All PSFMs are inserted into the rear of the chassis User Manual so SAS to SAS SATA J BOD Subsystem 1 5 1 PSFM Panel Power On Fail Indicator Power On Off Switch Fan 1 AC Power Inlet Plug Male The panel of the Power Supply Fan Module contains the Power On Off Switch the AC Inlet Plug and a Power On Fail Indicator showing the Power Status LED indicating ready or fail Each fan within a PSFM is powered independently of the power supply within the same PSFM So if the power supply of a PSFM fails the fan associated with that PSFM will continue to operate and cool the enclosure When the power cord connected from main power source is inserted to the AC Power Inlet the power status LED becomes RED When the switch of the PSFM is turned on the LED will turn GREEN When the Power On Fail LED is GREEN the PSFM is functioning normally has Power l Fan 1 an
2. SAS to SAS SATA J BOD Subsystem User Manual SAS to SAS SATA J BOD Subsystem Table of Contents Chapter 1 Introduction ooooooeeeeeeeseesssssssssscccccccceeeeeeeeesssssecscocccceeeseeesesessssssssseeceeeeee 3 LE POO oa E E E A A E E EE 4 12 Technical SO SGI a ONG scenene ae Ea E secgteseote estos onentpidasalicbepseeotees 5 13 Unpacking The JBOD SUDSYSTEI xs cccsccestescsceencsbcecsaccecsestaasne rA e S Ae e E AATETTA aes 6 1 4 Identifying Parts of the JBOD Subsystem Qu ec sessssessesesessesesssscsscsesessesecsssescesessssessssesessssesecseacssesesnsseeeeneans 7 TA SON NOW teats etc tect cca csc ec ce gece eee ce ence E E estates 7 TAZ RAM VON occ eect E E E E sequen ssatarsen teeteteeeeaoeeeeecse 8 1453 JBOD C ntroler Mod le sser e aE aA EEEE EEA E EEr 8 LASi JBOD Controller Pane leserene eain a EEEE E RaT 8 L5 Power Supply Fan Mogule Cc a1 1 eee eee ames oer eet ORR cP TRS eii Aa E En a eE Te Pi er Cone Pe Reser 9 EL PORNP AN Vl eE op nnceceue tensa tt cen E E E 10 IRo ESED Ey E go nner tet are E A re Pee AN A E ete ee E CO Tet eres ner ere Sere 11 LOL ECP Pane cl B en ae A E E A E E ene ete eee eee ee 11 t62 LCD Panel F unction BUTTONS cect a e eaa Er 12 I7 Bve Caor odul E e ns et mer rm A E eR resentment n Pe 13 t71 Disk Drive Status IndicatolS sssrini eee e a E ee aa E rE 13 172 DrveCarnmer Lock Indicator sessenta Eee EE EE NEE 14 Chapter 2 Installation of J BOD Subsystem 00000000ooooooo0eeeeeee
3. ch 3U 16 bays rackmount JBOD unit It features the latest SASII 6Gb s interface and designed to fit in with the environments which needed highly reliable and relentless data growth The JBOD subsystem is also a versatile SAS SATA Disk Expansion system ideal for high capacity and scalability storage in IT demands Based on the 6G SAS technology the JBOD subsystem supports the choice of SAS and SATA drive configurations to deliver the best cost performance index with higher bandwidth User Manual aoo SAS to SAS SATA J BOD Subsystem 1 1 Features 16 hot swappable drive bays in a rackmount 3U chassis Simultaneously support SAS or SATA disk Single SAS JBOD controller module Each SAS JBOD controller module has three mini SAS 4X ports Power Supply and cooling system contained in 1 module for efficient cooling Two 500W redundant hot swappable power supplies Incorporates a cableless design for maximum signal integrity Utilizes industry standard SCSI Enclosure Services to monitor enclosure and disk environmental conditions Enclosure Monitoring S E S support for standard enclosure management System LED indications Fan speed monitoring Power supply monitoring System voltage monitoring System temperature monitoring System alarm a User Manual SAS to SAS SATA J BOD Subsystem 1 2 Technical Specifications SAS SAS2 3Gb 6Gb or SATA I II Two 4x mini SAS 6Gb s expansion Pose refer to RAID controler speaeato
4. d Fan 2 The PSFM 2 has Power 2 Fan 3 and Fan 4 When the Power Supply of a PSFM fails the PSFM need not be removed from the slot if replacement is not yet available The fan will still work and provide necessary airflow inside the enclosure Q NOTE Each PSFM has one Power Supply and two Fans PSFM 1 In replacing the failed PSFM refer to section 3 2 2 of this manual NOTE After replacing the Power Supply Fan Module and turning on the Power On Off Switch of the PSFM the Power Supply will not power on immediately The Fans in the PSFM will spin up until the RPM becomes stable When Fan RPM is already stable the RAID controller will then power on the Power Supply This process takes more or less 30 seconds This safety measure helps prevent possible Power Supply overheating when the Fans cannot work 10 User Manual SAS to SAS SATA J BOD Subsystem 1 6 LCD Display Panel Model Name lt ALARM MENU 1 6 1 LCD Panel LED Power LED Power Fail LED Fan Fail LED Over Temperature LED Voltage Warning LED Reserved for RAID Subsystem f I Parts inction Power LED Green indicates power is ON If one of the redundant power supply unit fails this LED will turn to RED and alarm will sound Power Fail LED Turn RED when fan 1 or 2 fails or Fan Fail LED speed is lower than 500 RPM If disk temperatures exceed 60 C Over Temperature LED the Over Temperature LED will turn RED and alarm will sound A
5. d to restart the J BOD controller Normally used in single JBOD Controller mode If already to connect to Controller CLI gt reset User Manual 23 SAS to SAS SATA J BOD Subsystem 3 3 Replacing J BOD Subsystem Components 3 3 1 Replacing J BOD Controller Module When replacing a failed Controller Module please follow these steps 1 Make sure the subsystem is in power off state Loosen the thumbscrews on the sides of the Controller Module case Use the Controller handle to pull out the defective Controller 3 Insert and slide the new Controller in Note that it may be necessary to remove the old defective Controller Module from the case and install the new one 4 Tighten the thumbscrews on the sides of the Controller Module case baal I _ Soe N o Da gt wen t 24 User Manual SAS to SAS SATA J BOD Subsystem 3 3 2 Replacing Power Supply Fan Module When replacing a failed power supply fan module PSFM please follow these steps Turn off the Power On Off Switch of the failed PSFM Disconnect the power cord from the AC Inlet Plug of PSFM Loosen thumbscrews of the PSFM Use the handle to pull out the defective PSFM Before inserting the new PSFM make sure the Power On Off Switch is on Off state U AA W N e 6 Insert and slide the new PSFM in until it clicks into place I MPORTANT When the subsystem is online and a Power Supply fails and the replacemen
6. ed Set Fan Speed Level 7 F W v v gt Set ALARM Enter Password SetAlarmBeep Warning Alarm Sound 1 4 Disable W W CriticalAlarm Sound 1 4 Disable a Mute Beep if ivf gt Set PASSWORD Enter Password Sat New PWD wf Set New Value iv w gt SAVE CONFIG Enter Password Save Config Exit No Sel Yes 7 Ca W gt SYSTEM RESET Enter Password Reset System Exit No Sel Yes User Manual 2i SAS to SAS SATA J BOD Subsystem 3 2 Upgrading Firmware Upgrading Firmware Through Terminal NOTE It is important to stop I O access to J BOD subsystem during a firmware upgrade 1 Please use the RS232 cable RJ 11 to DB9 and to connect JBOD RS232 Port and PC COM1 Port or change to other COM Port as necessary 2 Open Windows HyperTerminal Program Connect using COM1 COM Port used in Step1 Baud Rate 115200 n 8 1 Flow Control None 3 Press the Enter key and the password prompt will be displayed 4 Key in the password Default password 00000000 to login to CLI 5 At CLI prompt input the command to update firmware a CLI gt NOTE fdl code 0 is the command to update flash firmware code fw file fdl mfgb 0 is the command to update CFG data code rom file Make sure you have both files before updating b CLI gt fdl mfgb 0 Please Use XModem Protocol for File Transmission Use Q or q to q
7. moval Drive Carrier is unlocked Drive Carrier is locked When the Lock Groove is horizontal this indicates that the Drive Carrier is locked Lock and unlock the Drive Carriers by using a flat head screw driver ry User Manual SAS to SAS SATA J BOD Subsystem Chapter 2 Installation of J BOD Subsystem 2 1 Powering On 1 Plug in the power cords into the AC Power Input Socket located at the rear of the subsystem Power On Off Switch AC Power Input Socket NOTE The subsystem is equipped with redundant full range power supplies with PFC power factor correction The system J will automatically select voltage 2 Turn on each Power On Off Switch to power on the subsystem 3 The Power LED on the front panel will turn green User Manual a5 SAS to SAS SATA J BOD Subsystem 2 2 Disk Drive Installation This section describes the physical locations of the hard drives supported by the Subsystem and give instructions on installing a hard drive The subsystem Supports hot swapping allowing you to install or replace a hard drive while the subsystem is running 2 2 1 Installing a SAS Disk Drive in a Disk Tray 1 Unlock the Disk Trays using a flat head screw driver by rotating the Lock Groove Disk Tray is unlocked Tray Open Button 3 Pull out an empty disk tray 16 User Manual SAS to SAS SATA J BOD Subsystem 4 Place the hard drive in the disk tray Turn the disk tra
8. n Monitor Port support Yes enclosure of Hot Swap Trays Disk Status I ndicator Access Fail LED Power LED Power requirements AC 90V 264V Full Range 10A 5A 47Hz 63Hz Physical Dimension 590 L x 482 W x 131 H mm Request optional dongle board for SATA I III hard drive Tray Lock Yes User Manual 5S SAS to SAS SATA J BOD Subsystem 1 3 Unpacking the J BOD Subsystem The shipping package contains the following JBOD Subsystem Unit Two 2 power cords One 1 serial cable RJ 11 to DB9 One 1 external Mini SAS cable SFF 8088 to SFF 8088 One 1 PSFM Plate Cover User Manual 6 User Manual SAS to SAS SATA J BOD Subsystem 1 4 Identifying Parts of the J BOD Subsystem The illustrations below identify the various parts of the expansion chassis 1 4 1 Front View Smart LCD Panel Drive Carriers Slot 4 Slot 3 Slot 2 Slot 1_ Slot 8 Slot 7 Slot 6 Slot 5 Slot 12 Slot 11 Slot 10 Slot9 Slot 16 Slot 15 Slot 14 Slot 13 User Manual Ea SAS to SAS SATA J BOD Subsystem 1 4 2 Rear View JBOD Controller Module Power Supply Power Supply Fan Module 1 Fan Module 2 1 4 3 JBOD Controller Module 1 4 3 1 JBOD Controller Panel SAS Expansion Ports e d N gt NA Link LED i Activity LED SAS In Port RS 232 Port O B User Manual SAS to SAS SATA J BOD Subsystem Part Description S
9. n alarm will sound if detected voltage in the controller is Voltage Warning LED g g abnormal and LED will turn RED User Manual ETE SAS to SAS SATA J BOD Subsystem 1 6 2 LCD Panel Function Buttons Up and Down Use the Up or Down arrow keys to go through the information on the OM BUTTONS hd LCD screen This is also used to move between each menu A This is used to enter the option Select button you have selected l Press this button to return to the a User Manual SAS to SAS SATA J BOD Subsystem 1 7 Drive Carrier Module The Drive Carrier Module houses a 3 5 inch hard disk drive It is designed for maximum airflow and incorporates a carrier locking mechanism to prevent unauthorized access to the HDD 1 7 1 Disk Drive Status I ndicators Disk Activity _ Indicator Disk Status Indicator This LED will blink blue when the hard drive is being Disk Activity Indicator accessed Green LED indicates power is on and hard drive status is good for this slot If there is no hard drive the LED is Disk Status Indicator Red The fault indicator depends on the RAID card or RAID Controller definition User Manual EEN SAS to SAS SATA JBOD Subsystem 1 7 2 Drive Carrier Lock Indicator Every Drive Carrier is lockable and is fitted with a lock indicator to indicate whether or not the carrier is locked into the chassis or not Each carrier is also fitted with an ergonomic handle for easy carrier re
10. ng the RAI D Environment After power on the enclosure the screen on the LCD panel will show the following message Model Name lt ALARM MENU Press the WV button to enter the menu The following tree diagram is a Summary of the various monitor functions that can be accessed through the LCD panel Model Name lt ALARM MENU E z Alarming From lt Device gt _ lt TEMPERATURE Enclosure Chip HDDO1 Y HDD16 v iw lt FAN SPEED Fanti i Fandd w lt POWER SUPPLY Power01 ON v Power02 ON v lt VOLTAGE lt N Y 5y 3 3V e B12V 20 User Manual SAS to SAS SATA J BOD Subsystem Press the W button to enter the configure menu The enclosure has a setup configuration utility allows user to set temperature LINK FAN Alarm and Password The following tree diagram is a Summary of the various setting functions that can be accessed through the LCD panel Wi W iy gt Set TEMP Enter Password Enclosure St High Limit Y Set Low Limit i i Chip r Set High Limit Y Set Low Limit i nf HDD Set High Limit F Set Low Limit F F P gt SetLINK EnterPassword HDDO1 Set Max Rate 6 0G 1 5G Set Min Rate 6 06 1 5G l wf y HDDI6 Set Max Rate 6 06 1 56 Set Min Rate 6 0G 1 5G Wi W W gt 56 FAN Enter Password SlowestSpeed Set Fan Speed Level 5 W if Warning Spe
11. ower Supply Fan Module Plate Cover a User Manual
12. ssssccceeeesssssssceeee 15 AE PON Oee E AA 15 22 Disk Dive asi lid 6 iere r re NE E E re a A AEN 16 2 2 1 Installing a SAS Disk Drive in a Disk Tray ssessssossossoossoosseesssosssesssosseesseesseessrensseossrnssrnssrnssrnssrnseeessens 16 2 3 Connecting the JBOD SUDSySteN s siirssissssisssiiiasraeisaeriiiroirarae enseia asarni echo sacdesinelcadhudincdesiaseeubaadsbene dees 19 Zoe CONE O AS HEA e renin on ert viene re dee rere eer rae ee 19 2 3 2 Connecting to RAID SUS YSU CIV siccdccccctescatsses ixcdeccenteacabestse2eadeanedacsiassivesechesaskecteetieusbeterdesleciewbsscsbeutsduoenes 19 Chapter 3 Maintenance eee ee re ee re ee ee en ern 20 Sek Monitoring the RAID Et POM iG Oi sisirin rar rer aae aSa ir eais TAa irie EA eet eves 20 3 UPoramnd FENA O a E N N N 22 3 3 Replacing JBOD Subsystem COMPONENMS ecessessesesesesecsssssesscseseseesssesesessesssnsscsesessesssessssescseseeseseeeseseeseees 24 3 3 1 Replacing JBOD Controller Module ss sssessonssesesseesssesssesssesssesssenssenssensersnsesnsennsennsennseossensnenssenssenssenssens 24 3 3 2 Replacing Power Supply Fan MOdule nu ccsessssssssesssscscssscsssesssessssssessssesecsssssessssssesessessseseseessaeseesees 25 3 3 2 1 Replacing Power Supply Fan Module with Plate COVES ccccsesesseseseeesseseeeseeseseeeeeeseseeen 26 0O a User Manual SAS to SAS SATA J BOD Subsystem Chapter 1 Introduction The 16 bays J BOD Subsystem The JBOD subsystem is a 19 in
13. t Power Supply module is not yet available the failed Power Supply Module can be replaced with the Plate Cover This is to maintain proper airflow within the enclosure Refer to next section When replacing a failed component online it is not recommended to remove the failed component for a long period of time proper air flow within the enclosure might fail causing high controller disk drive temperature 7 Connect the power cord to the AC Inlet Plug of PSFM 8 Tighten the thumbscrews of the PSFM 9 Turn on the Power On Off Switch of the PSFM NOTE After replacing the Power Supply Fan Module and turning on the Power On Off Switch of the PSFM the Power Supply will not power on immediately The Fans in the PSFM will spin up until the RPM becomes stable When Fan RPM is already stable the RAI D controller will then power on the Power Supply This process takes more or less 30 seconds This safety measure helps prevent possible Power Supply overheating when the Fans cannot work User Manual 25 SAS to SAS SATA J BOD Subsystem 3 3 2 1 Replacing Power Supply Fan Module with Plate Cover When replacing a failed power supply fan module PSFM with Plate Cover please follow these steps Turn off the Power On Off Switch of the failed PSFM Disconnect the power cord from the AC Inlet Plug of PSFM Loosen thumbscrews of the failed PSFM Pull out the defective PSFM Insert the PSFM Plate Cover carefully Se A a P
14. uit Download before starting XModem Offset 0x0 c Select Function menu to transfer CFG data rom file Function gt Transfer gt Send File gt Browse gt Open and select the rom file for example 8016 mfgdat6 20110131 rom firmware folder location Select Xmodem Protocol to send firmware file Only need about 60 seconds to finish sending firmware file If not please repeat steps B and D again Note If won t to transfer CFG data rom file Press Q or q to quit Download before starting data transfer d CLI gt fdi code 0 Please Use XModem Protocol for File Transmission Use Q or q to quit Download before starting XModem Offset 0x0 ees User Manual SAS to SAS SATA J BOD Subsystem e Select Functon menu to transfer firmware file Function gt Transfer gt Send File gt Browse gt Open and select the fw file for example 8016 07 01 09 96 20110211 fw from firmware folder location Select Xmodem Protocol to send firmware file Only need about 60 seconds to finish sending firmware file If not please repeat steps D and E again Note If won t to transfer firmware data fw file Press Q or q to quit Download before starting data transfer f Use reset command to Restart JBOD or power cycle g Re login to JBOD CLI h Use sys command to verify J BOD firmware version CLI gt sys i If needed the reset command can also be use
15. y upside down Align the four screw holes of the SAS disk drive in the four Hole A of the disk tray To secure the disk drive into the disk tray tighten four screws on these holes of the disk tray Note in the picture below where the screws should be placed in the disk tray holes Tray Hole A NOTE All the disk tray holes are labelled accordingly User Manual ETA SAS to SAS SATA J BOD Subsystem 5 Slide the tray into a slot 6 Press the lever in until you hear the latch click into place The HDD Fault LED will turn green when the subsystem is powered on and HDD is good 7 If necessary lock the Disk Tray by turning the Lock Groove 1s User Manual SAS to SAS SATA J BOD Subsystem 2 3 Connecting the J BOD Subsystem 2 3 1 Connecting to SAS HBA The Enclosure supports SAS interface which provides fast 300MB data transfer rate using SAS phy The package comes with one SAS cable for single JBOD controller module Attach one end of the SAS cable to the SAS IN Port and the other end to the host bus adapter s HBA external SAS connector or to the SAS Switch The host bus adapter is installed in your Host computer system 2 3 2 Connecting to RAI D Subsystem Attach one end of the SAS cable to the SAS IN Port of the JBOD controller module and the other end to the SAS Expansion Port on the RAID controller of RAID subsystem User Manual a9 SAS to SAS SATA J BOD Subsystem Chapter 3 Maintenance 3 1 Monitori

Download Pdf Manuals

image

Related Search

Related Contents

BoConcept 183 Assembly Instruction  Christie DWU670-E DLP User Guide Manual  s-max sel la  Tecumseh AGA5546EXH Drawing Data  ANEXO 3 CARTERAS DE CAMPO  Un travail ré-éducatif ano-rectal de l`enfant de moins de cinq ans    Emerson EWC20D4 TV DVD Combo User Manual  EM6225 Câmera IP Pan/Tilt e-CamView HD  Soluções para Fabricante de Máquinas  