Home
        CS500B User Manual - OPTI-UPS
         Contents
1.  of business opportunity  loss of goodwill  loss of data  loss of software  costs of  substitute equipment  interference with business relationships  claims by third  parties  or other commercial loss  even 1f advised of the possibility of such  damages    2  Any other damages  whether incidental  consequential or otherwise    3  Any claim against the customer by any other party     Registration                               The standard warranty is 2 years from the date of purchase  includes battery   Please                                                                 register to assure your product warranty  There are two ways to register  X    1  Please fill in the registration form  and send it to OPTI International by fax or regular      mail  5    2  You can choose on line registration as well                           ee eee     Vertical    
2.  slots on the bottom of the UPS   This warranty is valid only for the first consumer purchaser   What the warranty does not cover   1  Any product on which the serial number has been defaced  modified or  removed   2  Damage  deterioration or malfunction resulting from  _   p  a  Accident  misuse  neglect  fire  water  or other acts of nature  unauthorized ann     F   i                         product modification  or failure to follow instructions supplied with the o      product   o  b  Repair or attempted repair by anyone not authorized  j  c  The fault is result of accidental damage or damage in transit or  transportation  including but not limited to liquid spillage   d  Removal or installation of the product   e  Causes external to the product   f  Use of supplies or parts not meeting our specifications   g  Normal wear and tear   h  Any other cause which does not relate to a product defect   3  Removal  installation and set up service charges   Limitation of implied warranties   There are no warranties  express or implied  which extend beyond the description  contained herein including the implied warranty of merchantability and fitness for a  particular purpose     Exclusion of damages  Horizontal  Our liability is limited to the cost of repair or replacement of the product  We shall not  be liable for    1  Damage to other property caused by any defects in the product  damages based  upon inconvenience  loss of use of the product  loss of time  loss of profits  loss 
3. SUPS M    Www opti ups com    CS300B    User Manual    Data Line Surge Protection    CS500B   s exclusive communication protection ports will protect  any standard modem  PBX System or 10 100 BaseT connection  ports  This communication port can accommodate either the    phone  RJ 11  or network  RJ 45  jack           USB Port of    Computer    TEL   FAX      Modem   LAN    Battery  Fault   Over  Load    Placement    CS500B is intended for indoor use  only  its internal components are not  sealed from the environment    Please install CS500B in a protected  environment away from excessive heat  or excessive moisture     HLF    Charging the UPS first    The battery is fully charged at the  factory  However  user is recommended  to charge the battery at least 4  FOUR   hours before using UPS  since energy  loss may have occurred during  shipping or long duration storage  To  recharge the battery  simply let UPS be  plugged into an AC outlet     USB Communication Port    Please link CS500B USB port with computer USB  port using the USB cable which is attached inside the  box  Now  you can use the software  OPTI SAFE  SENTINEL  to control your computer and CSSOOB     Install Software    Connect Equipment to CS500B    Battery Backup  amp  Surge Protection Outlets   These two outlets not only provide surge protection but also backup power for your  equipment  In case of AC failure  battery power is automatically provided to two three  outlets  Please connect your main devices to the
4. ected runtime    your equipment slightly   equipment from the UPS    exceeds the capacity of outlets     Audible Noise  lt 45 dBA        355x110x90 mm   Dimensions  LW  gt H  14x4 3x3 5 inches     the UPS     The battery is slightly Consider replacing the battery   worn out    The battery is worn out  Consider replacing the battery     Weight  Net  2 5 kg  5 5 lbs   EMC RFI Compatibility  Safety Certifications C Tick   A Tick    UPS cannot be turned      Contact l    ontact your sales  representative     Contact Information  USA Australia Taiwan  Warranty OPTI UPS Corp  OPTI Australia Pty Ltd  OPTI International Corp     Tel  1 909 869 5700 Tel 61 3 9545 5322 Tel  886 2 2246 7272    eral TARTARI I Toll Free   888 OPTI UPS Toll Free  Toll Free 0800 029898  at the warranty covers  info  opti ups com AU  1800 678 428 info  opti ups com tw    We warrant this product to be free from defects in material and workmanship during http   www opti ups com NZ  088 OPTI UPS http   www opti ups com tw  the warranty period  If a product proves to be defective in material or workmanship info  opti ups com au    during the warranty period  we will at our sole option repair or replace the product  with a like product   How long the warranty is effective  Wall Mount of UPS  For accurate warranty period and conditions  please contact local branch offices or  your dealers  CS500B can be mounted to a wall surface  Please see the illustration below   Who the warranty protects  There are two key hole
5. s may occur    during the process  This is normal     Battery    Backup AC mode    Battery fault    Red LED flashes once  every 0 5 sec    None    Buzzes once every 4 sec  mode once every 4 sec    Yellow LED flashes  once every   sec    Ch  Green LED ON Buzzes once every 0 5 sec  abnormal                                                                      1  Remove the two screws on the  bottom of UPS                                2  Pull and open the battery cover                          3  Pull out the battery and disconnect the  two wires connecting the battery to  the UPS     4  Connect the wires to the new battery making sure that the red wire is connected to the red battery  terminal and the black wire is connected to the black battery terminal   5  Reverse the procedure from 3 to 1        Specifications Troubleshooting    Possible Cause    Unplug at least one piece of  equipment from the surge  protection outlets  Switch off  UPS  wait for 5 seconds  reset  the circuit breaker     Surge Protection Circuit breaker button  outlets stop providing   popped up as a result of  power to the overload    equipment    0 40  C  32 104  F    Storage Temperature  20 60  C   4 140  F    Recharge the battery by leaving  the UPS plugged in and load  disconnected from UPS     Battery undercharged or  depleted due to frequent  power outages        UPS doesn   t perform The power required by Unplug at least one piece of      Relative Humidity   0 to 95  Max Non condensing   to its exp
6. se outlets    Surge Protection Outlets   These two outlets provide surge protection but do not provide power during AC failure     ON OFF  Test  Silence    ae  a  F    Turn on the UPS    The UPS can be turned on after connecting to the utility power  After the UPS is turned  on  it conducts a self test and enters normal mode  Pressing the power button for 1 second  under normal mode will also enable the self test function  The silence function can be  enabled disabled by pressing the power button for 1 second in backup mode  In addition   the power button can be used as the master on off switch for your equipment by leaving  your equipment connected to UPS and switched on  To turn off the UPS  please press  power button until buzzer stops  about 2 seconds      Circuit Breaker    The circuit breaker button is located at the side  of CSSOOB  It will stick out to disconnect itself  from the utility power when an overload  condition occurs  If the button sticks out   disconnect nonessential equipment  Reset the  circuit breaker by pushing the button inward     Make sure your communication cable is connected to  your UPS as shown in the left picture    To install the software  follow the steps below   Simply insert software CD into your computer  and  the install process will begin  If not  run Setup exe  from the CD manually     Wall Jack    Circuit Breaker    Battery Replacement Procedure       Note  Follow this procedure for safe replacement of the battery  However  small spark
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Télécharger la fiche - Lubrifiants Fuel Economy  User Manual  QNAP IVW-FD133 video splitter  Manuel d`entretien Honda – PF 50 (Amigo)  User Manual - Grandbeing  warning - Albert Lee Appliance  ARF42 User Guide      TruVision NVR 50 User Manual - Surveillance    Copyright © All rights reserved. 
   Failed to retrieve file