Home

FX3G-2EYT-BD USER'S MANUAL

image

Contents

1. Associated Manuals Manual name Description Explains FX3S Series PLC specification details for I O wiring installation and maintenance Explains FX3G Series PLC specification details for I O wiring installation and maintenance JY997D48601 MODEL CODE 09R535 FX3S Series User s Manual Hardware Edition JY997D31301 MODEL CODE 09R521 FX3G Series User s Manual Hardware Edition FX3S FX3G FX3GC FX3U FX3UC Series Programming Manual Basic amp Applied Instruction Edition JY997D16601 MODEL CODE 09R517 Describes PLC programming for basic applied instructions and devices How to obtain manuals For the necessary product manuals or documents consult with the Mitsubishi Electric dealer from where you purchase your product Applicable standards FX3G 2EYT BD units made in September 2013 or later comply with the EC Directive EMC Directive Further information can be found in the following manual FX3s Series User s Manual Hardware Edition FX3G Series User s Manual Hardware Edition Regarding the standards that relate to the main unit please refer to either the FX series product catalog or consult with your nearest Mitsubishi product provider Attention e This product is designed for use in industrial applications Note e Manufactured by Mitsubishi Electric Corporation 2 7 3 Marunouchi Chiyoda ku Tokyo 100 8310 Japan e Manufactured at Mitsubishi Electric Corporatio
2. The version number can be checked by monitoring D8001 D8101 as well the last three digits indicate the version number e Only one 2EYT BD can be used per main unit Never stack up two or more expansion boards For details on the system configuration refer to the following manual FX3S Series User s Manual Hardware Edition FX3G Series User s Manual Hardware Edition 5 2 General Specifications The general specifications are equivalent to the PLC main unit For general specifications refer to the following manuals FX3S Series User s Manual Hardware Edition FX3G Series User s Manual Hardware Edition 5 3 Performance Specification Item Specification FX3S Series User s Manual Hardware Edition FX3G Series User s Manual Hardware Edition Other equipment Q Independent grounding Best condition Shared grounding Good condition e The grounding wire size should be AWG 22 to 20 0 3 to 0 5 mm e The grounding point should be close to the PLC and all grounding wire should be as short as possible Common grounding Not allowed This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage c
3. FX3S Series PLC specification details for I O FX3S Series User s Manual JY997D48601 3 If an overload of the 24 V DC service power supply occurs the voltage Manufacturer Caulking tool Hardware Edition MODEL CODE wiring installation and automatically drops inputs in the PLC are disabled and all outputs are turned 09R535 maintenance off Phoenix Contact Co Ltd Al 0 5 8WH Coe 2 Explains FX3G Series PLO 1 Terminal block mounting screws External circuits and mechanisms should be designed to ensure safe or CRIMPFOX 6T F JY997D31301 machinery operation in such a case 4 Note that when an error occurs in a transistor output device the output could be held either on or off For output signals that may lead to serious accidents external circuits and mechanisms should be designed to ensure safe machinery operation in such a case 2 Output LED BYO LED The LED is lit when BYO is on BY1 LED The LED is lit when BY1 is on LEDs correspond to each output terminal Describes PLC programming ow Uo for basic applied instructions BYO BY1 d devices Clee 3 Mounting holes 2 3 2 4 Connector cover 5 Main unit connector 6 Terminal block for output European 7 Memory cassette Display module connector FX3G Series User s Manual Hardware Edition specification details for I O wiring installation and maintenance 1 Old model name CRIMPFOX ZA 3 2 Old model name CRIMPFOX UD 6 Strand wire single w
4. environment specifications described in PLC main unit manual Hardware Edition Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or expose it to high temperature condensation or rain and wind If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur e Make sure to affix the expansion board with tapping screws Tightening torque should follow the specifications in the manual Loose connections may cause malfunctions e Use screwdrivers carefully when performing installation work thus avoiding accident or product damage e When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions e Do not touch the conductive parts of the product directly Doing so may cause device failures or malfunctions e Connect expansion board securely to their designated connectors Loose connections may cause malfunctions For installation uninstallation details refer to the following manual FX3s Series User s Manual Hardware Edition FX3G Series User s Manual Hardware Edition 3 Wiring DESIGN PRECAUTIONS Z WARNING e Make sure to have the following safety circuits outside of the PLC to ensure safe system operation even during external power supply pr
5. has been manufactured under strict quality control However M8116 When X000 is ON drive BYO M8116 Output circuit insulation Photocoupler insulation when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system MO Output operation display LED lighting when photocoupler is driven When M0 is ON drive BY1 M8117 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN 0 point This number is not related to the maximum number of input output points of the PLC Cy Number of occupied I O points
6. sRelsience STARTUP AND MAINTENANCE WARNING Manufacturer PRECAUTIONS SZS 0 4 2 5 Phoenix Contact Co Ltd e Do not touch any terminal while the PLC s power is on Doing so may cause electric shock or malfunctions 3 2 Wiring of output For the terminal configuration refer to Section 1 2 Sink output wiring Before cleaning or retightening terminals cut off all phases of the power supply externally Failure to do so may cause electric shock Before modifying or disrupting the program in operation or running the PLC carefully read through this manual and the associated manuals and ensure the safety of the operation An operation error may damage the machinery or cause accidents STARTUP AND MAINTENANCE CAUTION PRECAUTIONS e Do not disassemble or modify the unit Doing so may cause fire equipment failures or malfunctions For repair contact your local Mitsubishi Electric representative wis e Do not drop the product or exert strong impact to it Source output wiring Doing so may cause damage DISPOSAL 5 to 30 V DC PRECAUTIONS Z CAUTION e Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device TRANSPORTATION AND STORAGE PRECAUTIONS CAUTION e The product is a precision instrument During transportation avoid any impacts Failure to do so may cause failures in the product After transportation verify the o
7. Contact Co Ltd Stick terminal with insulating sleeve Contact area Crimp area Insulation sleeve 2 6mm 0 1 When using a stick terminal with insulating sleeve choose a wire with proper cable sheath referring to the above outside dimensions or otherwise the wire cannot be inserted easily The tightening torque must be 0 22 to 0 25 Nem Do not tighten terminal screws exceeding the specified torque Failure to do so may cause equipment failures or malfunctions 4 Tool l l 4 3 Caution on Creation of Programs For tightening the terminal use a With e When the END instruction of the program is executed the output process is commercially available small screwdriver straight tip completed The interruption output processing of HSCS and HSCR etc are not having a straight form that is not widened carried out toward the end as shown right Output refreshing by REF instruction can not be done Caution l a es e Do not use the special auxiliary relay for an instruction by which the bit device is of if the eame or screwdriver grip is too gt H ke1 three points or more such as comparison result of the CMP instruction and small nolmening eee eee able comparison result of the ZCP instruction is occupied 1 Be ethigved Use Me following Do not use the special auxiliary relays for the operand of each application oe pee instruction as data K1M8116 and K2M8116 etc approximately 25 mm 0 98 5 Specification
8. JY997D51401A A _ JAPANESE B ENGLISH 9 MITSUBISHI ELECTRIC PROGRAMMABLE CONTROLLERS MELSEG F Side B FX3G 2EYT BD USER S MANUAL Manual Number JY997D51401 This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective September 2013 Specifications are subject to change without notice 2013 Mitsubishi Electric Corporation F X 3G Safety Precaution Read these precautions before use This manual classify the safety precautions into two categories and AXGAUTION Indicates that incorrect handling may cause hazardous Z WARNING conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on circumstances procedures indicated by 4 CAUTION may also be linked to serious results In any case it is important to follow the directions for usage
9. anual and the associated manuals and ensure the safety of the operation An operation error may damage the machinery or cause accidents 3 2 Wiring of output For the terminal configuration refer to Section 1 2 Sink output wiring STARTUP AND MAINTENANCE PRECAUTIONS CAUTION e Do not disassemble or modify the unit Doing so may cause fire equipment failures or malfunctions For repair contact your local Mitsubishi Electric representative e Do not drop the product or exert strong impact to it Doing so may cause damage Source output wiring DISPOSAL PRECAUTIONS CAUTION e Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device 5 to 30 VDC TRANSPORTATION AND STORAGE PRECAUTIONS CAUTION e The product is a precision instrument During transportation avoid any impacts Failure to do so may cause failures in the product After transportation verify the operations of the product 3 3 Grounding Grounding should be performed as stated below e The grounding resistance should be 100 Q or less e Independent grounding should be performed for best results When independent grounding is not performed perform shared grounding of the following figure For details refer to the following manual 5 1 Applicable PLC Model name FX3S Series PLC Applicability Ver 1 10 or later Ver 2 20 or later FX3G Series PLC
10. aused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life 4 Device allocation and program example 4 1 Device allocation Each output of 2EYT BD is allocated a special auxiliary relay The ON OFF state of each output is reflected in its corresponding special auxiliary relay Number of output points 2 points Output connecting type Terminal block European type Output form Transistor Sink Source External power supply 5 to 30 V DC Resistance load 0 5 A 1 point Inductive load 12 W 24 V DC OFF to ON Response time ON to OFF 0 2 ms or less Input terminal Special auxiliary relays Max load 4 2 Program example Turn the special auxiliary relay allocated to each output ON and OFF by program e Before using the product for special purposes such as nuclear power electric of PLC Open circuit leakage current 0 1 mA or less 30 V DC power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric x000 ON voltage 1 5 V or less e This product
11. e DESIGN PRECAUTIONS CAUTION e Do not bundle the control line together with or lay it close to the main circuit or power line As a guideline lay the control line at least 100 mm 3 94 or more away from the main circuit or power line Noise may cause malfunctions WIRING PRECAUTIONS WARNING e Make sure to cut off all phases of the power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product WIRING PRECAUTIONS CAUTION e Connect the DC power supply to the dedicated terminals specified in the manual of the PLC main unit If an AC power supply is connected to a DC input output terminal or DC power supply terminal the PLC will burn out When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Do not wire vacant terminals externally Doing so may damage the product Make sure to observe the following precautions in order to prevent malfunctions under the influence of noise Do not bundle the power line or input line together with or lay it close to the main circuit high voltage line or load line Otherwise noise disturbance and or surge induction are likely to take place As a guideline lay the control line at least 100mm 3 94 or more away from the main circuit or high voltage lines Make sure to prope
12. e power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product INSTALLATION PRECAUTIONS CAUTION e Use the product within the generic environment specifications described in PLC main unit manual Hardware Edition Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or expose it to high temperature condensation or rain and wind If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur e Make sure to affix the expansion board with tapping screws Tightening torque should follow the specifications in the manual Loose connections may cause malfunctions e Use screwdrivers carefully when performing installation work thus avoiding accident or product damage e When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions e Do not touch the conductive parts of the product directly Doing so may cause device failures or malfunctions e Connect expansion board securely to their designated connectors Loose connections may cause malfunctions For installation uninstallation details refer to the following manual FX3s Series User s Manual Hardware Edition FX3G Se
13. eries User s Manual Hardware Edition occur as a result of using the contents noted in this manual 5 3 Performance Specification 4 Device allocation and program example p Warranty 41 Devi Il ti Item Specification Mitsubishi will not be held liable for damage caused by factors found not to be i evice alloca wes l 7 Number of output points 2 points the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Each output of 2EYT BD is allocated a special auxiliary relay l l 7 Mitsubishi products damage secondary damage accident compensation The ON OFF state of each output is reflected in its corresponding special auxiliary Output connecting type Terminal block European type caused by special factors unpredictable by Mitsubishi damages to products relay i ishi f i y Output form Transistor Sink Source other than Mitsubishi products and to other duties Input terminal Special auxiliary relays E xternal power suppl 5 to 30 V DC i ZRK A N For safe use Resistance load 0 5 A 1 point Max load imductivalosd 12 W 24V DC e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in 4 2 Program example Response time OFF to ON O2iisor less a device or system used in purposes related to human life Turn the special auxiliary relay allocated to each output ON and OFF by program ON to OFF e Before using the product for special purposes such as
14. erwise noise disturbance and or surge induction are likely to take lace re a guideline lay the control line at least 100mm 3 94 or more away from the main circuit or high voltage lines Make sure to properly wire to the terminal block European type in accordance with the following precautions Failure to do so may cause electric shock equipment failures a short circuit wire breakage malfunctions or damage to the product The disposal size of the cable end should follow the dimensions described in the manual Tightening torque should follow the specifications in the manual Twist the end of strand wire and make sure that there are no loose wires Do not solder plate the electric wire ends Do not connect more than the specified number of wires or electric wires of unspecified size Affix the electric wires so that neither the terminal block nor the connected parts are directly stressed 3 1 Applicable Cable and Terminal Tightening Torque 3 1 1 Terminal block European type 1 Wire size Wiring to input device should use 22 to 20 AWG wire 2 Applicable cable Type Wire size Single wire 0 3 to 0 5 mm2 AWG22 to 20 2 wire 2 pieces of 0 3 mm2 AWG22 3 Termination of cable end Strip the coating of strand wire and twist the cable core before connecting it or strip the coating of single wire before connecting it An alternative connection is to use a ferrule with insulating sleeve lt Reference gt Explains
15. ire ae 9mm 0 35 MODEL CODE 09R521 Stick terminal with insulating sleeve Contact area Crimp area FX3S FX3G FX3GC FX3U FX3UC Series Programming Manual Basic amp Applied Instruction Edition JY997D16601 Insulation sleeve MODEL CODE 09R517 DESIGN PRECAUTIONS CAUTION e Do not bundle the control line together with or lay it close to the main circuit or power line As a guideline lay the control line at least 100 mm 3 94 or more away from the main circuit or power line Noise may cause malfunctions How to obtain manuals For the necessary product manuals or documents consult with the Mitsubishi Electric dealer from where you purchase your product 2 6mm 0 1 41 represents vacant terminals Do not wire vacant terminals externally When using a stick terminal with insulating sleeve choose a wire with proper cable sheath referring to the above outside dimensions or otherwise the wire cannot be inserted easily The tightening torque must be 0 22 to 0 25 Nem Do not tighten terminal screws exceeding the specified torque Failure to do so may cause equipment failures or malfunctions WIRING PRECAUTIONS WARNING e Make sure to cut off all phases of the power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product 4 Tool l l 4 3 Caution on Creation of Programs For tightening the
16. n Himeji Works 840 Chiyoda machi Himeji Hyogo 670 8677 Japan e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany 1 Outline The FX3G 2EYT BD output expansion board hereinafter called 2EYT BD is an expansion board to be installed in the FX3S FX3G series programmable controller hereinafter referred to as PLC to add two transistor outputs 1 1 Incorporated Items Verify that the following product and items are included in the package Product FX3G 2EYT BD output expansion board e M3x8 tapping screws for installation 2 pcs e Side cover e USER S MANUAL This manual Accessories 1 2 External Dimensions and Part Names Unit mm inches 4 5 Connector cover is 3 removed MITSUBISHI A 2 1 MASS Weight 20 g 0 05 Ibs 14 1 0 6 CAN 6 Terminal Layout 1 Terminal block mounting screws 2 Output LED BYO LED The LED is lit when BYO is on BY1 LED The LED is lit when BY 1 is on LEDs correspond to each output terminal gU LI BYO BY1 3 Mounting holes 2 03 2 4 Connector cover 5 Main unit connector 6 Terminal block for output European 7JMemory cassette Display module connector 41 represents vacant terminals Do not wire vacant terminals externally A 2 Installation INSTALLATION PRECAUTIONS WARNING e Make sure to cut off all phases of th
17. nuclear power electric of PLC Open circuit leakage current 0 1 mA or less 30 V DC power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric ON voltage 1 5 V or less e This product has been manufactured under strict quality control However X000 8116 When X000 is ON drive BYO M8116 Output circuit insulation Photocoupler insulation when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system MO Output operation display LED lighting when photocoupler is driven M8117 When MO is ON drive BY1 M8117 0 point MITSUBISHI ELECTRIC CORPORATION Number of occupied I O points This number is not related to the maximum HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN number of input output points of the PLC p PULP HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN side JY997D51401A B E A JAPANESE B ENGLISH 9 MITSUBISHI ELECTRIC PROGRAMMABLE CONTROLLERS MELSEG FX3G 2EYT BD USER S MANUAL Manual Number JY997D51401 This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place
18. oblems or PLC failure Otherwise malfunctions may cause serious accidents 1 Most importantly have the following an emergency stop circuit a protection circuit an interlock circuit for opposite movements such as normal vs reverse rotation and an interlock circuit to prevent damage to the equipment at the upper and lower positioning limits 2 Note that when the PLC CPU detects an error such as a watchdog timer error during self diagnosis all outputs are turned off Also when an error that cannot be detected by the PLC CPU occurs in an input output control block output control may be disabled External circuits and mechanisms should be designed to ensure safe machinery operation in such a case WIRING PRECAUTIONS CAUTION e Connect the DC power supply to the dedicated terminals specified in the manual of the PLC main unit If an AC power supply is connected to a DC input output terminal or DC power supply terminal the PLC will burn out When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Do not wire vacant terminals externally Doing so may damage the product Make sure to observe the following precautions in order to prevent malfunctions under the influence of noise Do not bundle the power line or input line together with or lay it close to the main circuit high voltage line or load line Oth
19. perations of the product 3 3 Grounding Grounding should be performed as stated below 5 1 Applicable PLC e The grounding resistance should be 100 or less Model name Applicability e Independent grounding should be performed for best results When independent andi is a performed perform shared grounding of PASSEIG PO the following figure FX3G Series PLC Ver 2 20 or later For details refer to the following manual gt FX3S Series User s Manual Hardware Edition The version number can be checked by monitoring D8001 D8101 as well the last three FX3G Series User s Manual Hardware Edition digits indicate the version number e Only one 2EYT BD can be used per main unit Never stack up two or more expansion boards For details on the system configuration refer to the following manual FX3S Series User s Manual Hardware Edition Other equipment Q Independent grounding Shared grounding Common grounding FX3G Series User s Manual Hardware Edition Best condition Good condition Not allowed 5 2 General Specifications The grounding wire size should be AWG 22 to 20 0 3 to 0 5 mm a la ll ca ad aac e E E E E eee poi f or general specifications refer to the following manuals e De T a a be close to the PLC and all grounding wire should _ FX3S Series User s Manual Hardware Edition held responsible for any problems involving industrial property rights which may e as short as possible FX3G S
20. ries User s Manual Hardware Edition 3 Wiring DESIGN PRECAUTIONS Z WARNING e Make sure to have the following safety circuits outside of the PLC to ensure safe system operation even during external power supply problems or PLC failure Otherwise malfunctions may cause serious accidents 1 Most importantly have the following an emergency stop circuit a protection circuit an interlock circuit for opposite movements such as normal vs reverse rotation and an interlock circuit to prevent damage to the equipment at the upper and lower positioning limits 2 Note that when the PLC CPU detects an error such as a watchdog timer error during self diagnosis all outputs are turned off Also when an error that cannot be detected by the PLC CPU occurs in an input output control block output control may be disabled External circuits and mechanisms should be designed to ensure safe machinery operation in such a case 3 If an overload of the 24 V DC service power supply occurs the voltage automatically drops inputs in the PLC are disabled and all outputs are turned off External circuits and mechanisms should be designed to ensure safe machinery operation in such a case 4 Note that when an error occurs in a transistor output device the output could be held either on or off For output signals that may lead to serious accidents external circuits and mechanisms should be designed to ensure safe machinery operation in such a cas
21. rly wire to the terminal block European type in accordance with the following precautions Failure to do so may cause electric shock equipment failures a short circuit wire breakage malfunctions or damage to the product The disposal size of the cable end should follow the dimensions described in the manual Tightening torque should follow the specifications in the manual Twist the end of strand wire and make sure that there are no loose wires Do not solder plate the electric wire ends Do not connect more than the specified number of wires or electric wires of unspecified size Affix the electric wires so that neither the terminal block nor the connected parts are directly stressed 3 1 Applicable Cable and Terminal Tightening Torque 3 1 1 Terminal block European type 1 Wire size Wiring to input device should use 22 to 20 AWG wire 2 Applicable cable Type Wire size Single wire 0 3 to 0 5 mm2 AWG22 to 20 2 wire 2 pieces of 0 3 mm2 AWG22 3 Termination of cable end Strip the coating of strand wire and twist the cable core before connecting it or strip the coating of single wire before connecting it An alternative connection is to use a ferrule with insulating sleeve lt Reference gt Manufacturer Caulking tool CRIMPFOX 6 i or CRIMPFOX 6T F 2 Al 0 5 8WH 1 Old model name CRIMPFOX ZA 3 2 Old model name CRIMPFOX UD 6 Strand wire single wire ae 9mm 0 35 Phoenix
22. roduct is designed for use in industrial applications Note e Manufactured by Mitsubishi Electric Corporation 2 7 3 Marunouchi Chiyoda ku Tokyo 100 8310 Japan e Manufactured at Mitsubishi Electric Corporation Himeji Works 840 Chiyoda machi Himeji Hyogo 670 8677 Japan e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany 1 Outline The FX3G 2EYT BD output expansion board hereinafter called 2EYT BD is an expansion board to be installed in the FX3S FX3G series programmable controller hereinafter referred to as PLC to add two transistor outputs 1 1 Incorporated Items Verify that the following product and items are included in the package Product FX3G 2EYT BD output expansion board e M3x8 tapping screws for installation 2 pcs e Side cover e USER S MANUAL This manual Accessories 1 2 External Dimensions and Part Names Unit mm inches 4 5 Connector cover is 3 removed MITSUBISHI A 2 1 MASS Weight 20 g 0 05 Ibs 15 1 14 1 0 6 CAN 6 Terminal Layout 2 Installation INSTALLATION PRECAUTIONS WARNING e Make sure to cut off all phases of the power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product INSTALLATION PRECAUTIONS CAUTION e Use the product within the generic
23. so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective September 2013 Specifications are subject to change without notice 2013 Mitsubishi Electric Corporation F X 3G Safety Precaution Read these precautions before use This manual classify the safety precautions into two categories WARNING and ACAUTION Indicates that incorrect handling may cause hazardous Z WARNING conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on circumstances procedures indicated by 4 CAUTION may also be linked to serious results In any case it is important to follow the directions for usage Associated Manuals Manual name Description Applicable standards FX3G 2EYT BD units made in September 2013 or later comply with the EC Directive EMC Directive Further information can be found in the following manual FX3s Series User s Manual Hardware Edition FX3G Series User s Manual Hardware Edition Regarding the standards that relate to the main unit please refer to either the FX series product catalog or consult with your nearest Mitsubishi product provider Attention e This p
24. terminal use a With e When the END instruction of the program is executed the output process is commercially available small screwdriver straight tip completed The interruption output processing of HSCS and HSCR etc are not having a straight form that is not widened toward the end as shown right carried out Output refreshing by REF instruction can not be done Caution _ ren e Do not use the special auxiliary relay for an instruction by which the bit device is of If the diameter of screwdriver grip is too o three points or more such as comparison result of the CMP instruction and small tightening torque will not be able to be achieved Use the following recommended screwdriver or an comparison result of the ZCP instruction is occupied Do not use the special auxiliary relays for the operand of each application instruction as data K1M8116 and K2M8116 etc 5 Specification STARTUP AND MAINTENANCE PRECAUTIONS appropriate replacement grip diameter approximately 25 mm 0 98 lt Reference gt Manufacturer WARNING Phoenix Contact Co Ltd SZS 0 4x2 5 Do not touch any terminal while the PLC s power is on Doing so may cause electric shock or malfunctions Before cleaning or retightening terminals cut off all phases of the power supply externally Failure to do so may cause electric shock Before modifying or disrupting the program in operation or running the PLC carefully read through this m

Download Pdf Manuals

image

Related Search

Related Contents

Satellite Phone User's Guide  Manuel pour contrôle VANEE modele 40460  Symantec Brightmail AntiSpam 6.0 (10298333) for PC, Unix, Sun, Linux  Español  Golf, GolfGTI, GolfGTD, GolfPlus edizione 06.2009  USER MANUAL ANEROID SPHYGMOMANOMETERS  シャ~プ加熱気化式加湿器 (HV-W50CX) をレンタルのお客様へ    Genesis Advanced Technologies GMT15A User's Manual  Samsung AR12FC3TAURX User Manual  

Copyright © All rights reserved.
Failed to retrieve file