1. Appendix Message Code Please measure target within OUtariengs distance of 0 05 to 50m Received signal too weak Use target plant 156 Received signal too strong Use target plant Wrong measurement or background brightness too high Shake too much Stabilize equipment and repreat measurement Important Icons Flashing Continuous measurement More singal power bar indicates stronger Received singal ae reflection singal with faster measurement Power indicator speed and higher accurac More battery bar indicates more battery EAW Batter indicator energy Flash of this icon means batteries run out Measurement results are stored at reverse time Darken target or change target Data storage Switch on off the equipment several times if the symbol still appears then your instrument is defective please call your dealer for assistance Hardware error Warranty We guarantees TWO year warranty All illustrations and technical specifications may be subject to change whitout prior notice Technical parameters of the product abide by the GB T 14267 2009 of the P R C National Standard
2. USER MANUAL English First of all thank you for your choice on the handheld laser distance meter Please carefully read the safety instructions and the user manual before using this product otherwise it may result in hazardous laser radiation and electric shock The person responsible for the equipment must ensure that all users understand these directions and adhere to them Safety Instructions 1 This product is a class II laser product Please DO NOT stare into beam at any time when operating this product 2 Please DO NOT Looking directly into the beam with optical aids e g binoculars telescopes 3 Please DO NOT remove any safety labels this product Equipment Performance 1 Measuring range is from 0 05 to 50m 2 Calculation function a Area b Volume c Height Pythagorean theorem d Addition and subtraction 3 Storage and recall of measurement results 4 Metric and British unit system 5 LCD with background light 6 Automatically switch off Technical Parameters Technical Specifications Measuring accuracy typically m 4 Stand deviation uals Range 0 05 50m A 7 100m A 11 Laser type 635nm lt 1mW classs2 Distance in m laser spot in mm 10 50m 6 30mm Measurements per battery set up to 5000 Distance unit 0 000m 0700 ft in Operating Temperature 0 40 C Storage Temperature 20 70 C Minimum and maximum measurements V Continuo
3. alkaline batteries or rechargeable batteries only 2 Please replace batteries when the symbol flashes permanently in the display Please remove the batteries before any long period of non use 4 Flat batteries must not be disposed of with household waste Care for the environment and take them to the collection points provided in accordance with national or local regulations w Equipment operation Switch on and off Long time press A button to switch on the equipment with default reference setting of single measurement mode rear reference and metric unit system At the same time battery state and laser reflection signal intensity indication as shown as figure C figure Clear Button Pressing C button to clear the last command or displayed data by lines Change Measurement Reference T Default setting of measurement is rear edge when switching on Pressing this button will change the measurement reference Display Background Light Default setting of LCD background is switching off Pressing the button will switch on or off LCD background light Unit Conversion Default setting of measurement unit is metric unit Long time pressing u it button will convert metric unit British unit from ft in to and so on as shown in figure D figure Measurement Signal mode Measurement When equipment is switched on pressing A button to activate the laser and aiming the laser onto target a
4. nd pressing 4 button gain to trigger single mode measurement the result is displayed immediately as shown in figure E figure Continuous mode Measurement When equipment is switched on long time pressing A button trigger continuous mode measurement with 1 1 symbol flashing MIN MINIMUM VALUE MAX MAXIMUM VALUE Current measurement value is displayed in LCD bottom line as shown in figure F t ill figure Functions Area Volume Indirect Measurement Pythagorean Theorem figure Press ip button to change measurement functions respectively as shown in figure G select corresponding function and begin the measurement Measurement Functions Lcons Measurement Sequence Single mode Measurement A Area Measurement 7 7 Volume Measurement i i i Height Measurement 1 DN IM N gt Height Measurement 2 i 7 7 Addition and Subtraction Functions The next measurement is added to the previous one The next measurement is subtracted from the previous one as shown in figure H Storage and recall of measurement results The equipment will automatically store the last 50 measurement results at reverse time On standby state shown in figure pressing or buttons will recall historical measurement results with the first reading as record No 1 and so on When 50 records are full the equipment will directly delete the first figure O reading and store the current reading
5. us measurement Vv Addition subtraction Vv Area volume pythagorean measurements V Spray proof dust protected IP54 Batteries AAAx1 5V Weight with batteries 215g Dimensions 126x50x28mm Prohibited Use 1 NOOB WD Opening of the equipment by using tools screwdrivers etc as far as not specifically permitted for certain cases Aiming directly into the sun Using outside the stated limits Immersing the equipment in water Cleaning the lens using alcohol or any other organic solvent Wiping the lens directly with fingers or other rough surfaces Powering the equipment beyond the rated DC voltage LCD Icon indication keypad functions 1 LASER ON 12 POWER ON MEASURING KE 2 REFERENCE 13 AREA VOLUME PYTHAGORAS 3 LEVEL INDICATION KEY 4 HISTORICAL READINGS 14 PLUS KEY 5 AREA VOLUME PYTHAGORAS 15 BACK LIGHT UNIT KEY EREPARING I6 CLEARIOFF KEY LCD and keypad description 6 Pe he LIU ftim 9 n an i pun bml Dml hi ana 5 Sor 12 13 14 15 Start up 1 Battery Installation a According to figures remove battery compartment lid with specified battery key b Insert batteries with correct polarity according to battery lid indications C Close the battery compartment lid and skew tight with the battery compartment key figure Caution 1 Please do not mix new and old batteries Use