1. Online assistance www agilent com find assist Americas Brazil tel 55 11 3351 7012 fax 55 11 3351 7024 Canada tel 1 877 894 4414 alt 1 303 662 3369 fax 1 800 746 4866 Mexico tel 1 800 254 2440 fax 1 800 254 4222 United States tel 800 829 4444 alt 1 303 662 3998 fax 800 829 4433 Asia Pacific and Japan Australia tel 1 800 802 540 fax 1 800 681 776 fax 1 800 225 539 China tel 800 810 0508 fax 800 810 0507 Hong Kong tel 800 933 229 fax 800 900 701 India tel 1600 112 626 fax 1600 113 040 Japan Bench tel 0120 421 345 alt 81 426 56 7832 fax 0120 01 2144 Japan On Site tel 0120 421 345 alt 81 426 56 7832 fax 0120 012 114 Singapore tel 1 800 275 0880 fax 65 6755 1214 South Korea tel 080 778 0011 fax 080 778 0013 Taiwan tel 0800 047 669 fax 0800 047 667 fax 886 3492 0779 Thailand tel 1 800 2758 5822 fax 1 800 656 336 Malaysia tel 1800 880 399 fax 1800 801 054 tel primary telephone number alt alternate telephone number fax FAX number in country number 5 6 05 Agilent L7222 Coaxial Transfer Switch Operating and Service Manual Contacting Agilent Europe Contacting Agilent Europe Online assistance www agilent com find assist Europe Austria Belgium Denmark Finland tel 0820 87 44 11 tel 32 0 2
2. 404 9340 tel 45 7013 1515 tel 358 10 855 2100 fax 0820 87 44 22 fax 32 0 2 404 9395 fax 45 7013 1555 fax 358 0 10 855 2923 France Germany Ireland Israel tel 0825 010 700 fax 0825 010 701 tel 01805 24 6333 fax 01805 24 6336 tel 353 0 1 890 924 204 fax 4 353 0 1 890 924 024 tel 4972 3 9288 504 alt 4972 3 9288 544 fax 4972 3 9288 520 Italy tel 39 0 2 9260 8484 fax 39 0 2 9544 1175 Luxemburg tel 32 0 2 404 9340 fax 432 0 2 404 9395 Netherlands tel 31 0 20 547 2111 fax 431 0 20 547 2190 Russia tel 7 095 797 3963 alt 7 095 797 3900 fax 7 095 797 3902 Spain tel 34 91 631 3300 fax 34 91 631 3301 Sweden tel 0200 88 22 55 alt 46 0 8 5064 8686 fax 020 120 2266 Switzerland French tel 0800 80 5353 opt 2 fax 41 0 22 567 5313 Switzerland German tel 0800 80 5353 opt 1 fax 41 0 1 272 7373 Switzerland Italian tel 0800 80 5353 opt 3 fax 41 0 22 567 5314 United Kingdom tel 44 0 7004 666666 fax 44 0 7004 444555 tel primary telephone number alt alternate telephone number fax FAX number in country number 5 6 05 Agilent L7222 Coaxial Transfer Switch Operating and Service Manual Contents Contents ROU B iba Eos Mad e aca athe bang e aha ee aes Paws cado Med ii WEEE COMPS
3. RFI 12 4 kV to outer conductor per IEC 61000 4 2 8 kV to center conductor per IEC 61000 4 2 Radiated Emission per CISPR 11 Agilent L7222C Coaxial Transfer Switch Operating and Service Manual Physical Specifications Physical Specifications The physical specifications of L7222C coaxial transfer switch is illustrated in Table 10 Table 10 L7222C Coaxial Transfer Switch Physical Specifications Dimensions Per Figure 7 Net weight kg Ib 0 1 0 23 Standard 5520 B 4 o 4 85 336 Fii a rase rye c 5 m E 100 LL fans 254 AUS A 1 1 250 te 2 C 231 9 M2 5X 0 457 65 Guy a e Option 100 amp 9 5520 8 32 yp 2 173 J 485 12 89 328 191 507 m d AH z d es 233 D Option 100 and 201 3x 386 12032 18 152 800 965 1 o6 380 1 E pH TE e 5537 AS as T m 4512 2 180 A A s HHI 1 800 o 9 H 1593 E 23 Do 3350 M 1 319 al _10 16 pa 0 780 56 80 2 236 D Note Dimensions are in millimeters and inches nominal unless specified L7222C A R c p E millimeter SMA f 8320 328 68 37 2 692 69 46 2 735 6 72 0 265 inches TYP REF REF REF Figure 7 Dimensions of L7222C Coaxial Transfer Switch Agilent L7222C Coaxial Transfer Switch Operating and 13 Service Manual Installation Installation Initial Inspe
4. 6 Now still in position A disconnect switch s Port 1 and Port 2 from network analyzer Then connect network analyzer s Port 1 and Port 2 to Port 3 and Port 4 of the switch Measure S11 S21 and S22 and verify against specifications in Table 6 Disconnect Port 3 and Port 4 from network analyzer Connect Port 1 and Port 2 of the network analyzer to switch s Port 1 and Port 4 respectively Refering to Table 2 standard drive or Table 3 TTL drive apply appropriate drive voltage to ensure switch is in position B path 1 connected to path 4 path 2 connected to path 3 Measure Su S21 and 22 and verify against specifications in Table 6 Now still in position B disconnect switch s Port 1 and Port 2 from network analyzer Then connect network analyzer s Port 1 and Port 2 to Port 2 and Port 3 of the switch Measure S11 S21 and S22 and verify against specifications in Table 6 Agilent L7222C Coaxial Transfer Switch Operating and Service Manual Adjustment Repair Maintenance Performance Tests Performance Tests The coaxial transfer switch can be tested to the accuracy of the specifications with a network analyzer or equivalent equipment of suitable accuracy If a network analyzer is available test the instrument using the procedure in the analyzer s operating manual Service Instructions The coaxial transfer switch do not have internal adjustments and should not be opened The L7222C coaxial transfer switch is no
5. Operating and Service Manual Agilent L7222C Coaxial Transfer Switch enge Agilent Technologies Manufacturing Part Number L7222 90001 Printed in Malaysia Print Date March 2007 Copyright Agilent Technologies Inc 2007 Notices Notices Agilent Technologies Inc 2007 No part of this manual may be reproduced in any form or by any means including elec tronic storage and retrieval or translation into a foreign language without prior agree ment and written consent from Agilent Technologies Inc as governed by United States and international copyright laws Manual Part Number 17222 90001 Edition First edition Mar 2007 Printed in Malaysia Agilent Technologies Inc Phase 3 Bayan Lepas Free Industrial Zone Bayan Lepas Penang 11900 Malaysia Certification Agilent Technologies certifies that this prod uct met its published specifications at the time of shipment from the factory Agilent Technologies further certifies that its cali bration measurements are traceable to the United States National Institute of Stan dards and Technology NIST formerly NBS to the extend allowed by the Institute s cali bration facility and to the calibration facili ties of the other International Standards Organization members Warranty The material contained in this document is provided as is and is subject to being changed without notice in future editions Further to the maximum extent permitted by ap
6. PME E iii Printing Copies of Documentation from the Web ii Contacting Agilent Americas Asia Pacific amp Japan iv Contains AcM EUr cs sushi D ae eaae du epu iet wed V General HOON iusso Cere re e etr RI elo Ke el rd 1 L Series Coaxial Transfer Switch Overview 0005 1 Pealub 8 op A RSP Gd REY SEE DU ES CREE LES ERPG RR ERE 1 Duine ts DOE Luces duck dace acpdca ao YA CE dca dede ou AERE das 3 Blanda DHVes corosesosshredo VR RE YEPPRRREAQM RO Coenen neds 4 Sml Ling TTL DOVE iov ox AE Y RP WR REO RV RU tern ene ns 4 Dist Eine TIL DENS Gao 6o sed Ee pe EE qe dude tpe du dp 3 Electronic Postion Indicator ie isssecot m etr RR 6 DOCUIT erani qaos qid e napi amp aco Kn CRY GbR Maik ae A RR OCUPA fi Environmental Specifications 2s se e kr ssw ees os Ii Physical SPOCIICAIONG e eneren e ade RO ees 12 Ts UE ode ono pid esq cbseEDR IR Ediki peku h PE CERE Es 13 Tunal InSpeclot suis bea es ea gid nels DOE a aC wa a 13 Upernns Esto usa cl steht dp ddr ead x 14 Operator s CHECK occcctceeceei sent e RR ror r er riss ERR ee 14 Pertoriauas TER io ons ae ee eer Mae ra ab A D dex cb RO dog 16 Per ves MeCN s asa dedi xav esed eod b Nd RR S add Ed Ps 16 AMEE MC 16 BOB o seo eni5sEbwceipes ake eee ehobbes eS AA ss qs ss 16 Munie nanee 644 4455 cad bE ERA ERR RE RN EP PIER PI Y 16 vi Agilent L7222 Coaxial Transfer Switch Operating and Service Manual L Series Coaxial Transfer Switch Overview Fe
7. atures General Information General Information Agilent L7222C coaxial transfer switch is designed for flexibility in signal routing applications and provides exceptional insertion loss repeatability of 0 03 dB low insertion loss and high isolation gt 80 dB Figure 1 L7222C Coaxial Transfer Switch Table 1 shows general details of L7222C coaxial transfer switch Table 1 General Information on L7222C Coaxial Transfer Switch Model Frequency Range Configuration L7222C DC to 26 5 GHz DPDT Guaranteed 0 03 dB insertion loss repeatability for 2 million cycles Excellent isolation typically gt 80 dB at 26 5 GHz Opto electronic indicators and interrupts Magnetic latching TTL 5V CMOS compatible optional Agilent L7222C Coaxial Transfer Switch Operating and 1 Service Manual General Information The L7222C can be used in a variety of applications such as switching two inputs and two outputs signal reversal switching or as a drop out switch Innovative design and careful process control mean the L7222C meet the requirements for highly repeatable switching elements in test instruments and switching interfaces L7222C offers exceptional insertion loss repeatability reducing sources of random errors in the measurement path and improving measurement uncertainty Switch life is a critical consideration in production test systems satellite and antenna monitoring systems and test instrumentation The longevity of t
8. calls attention to an operating procedure practice or the like that if not correctly per formed or adhered to could result in per sonal injury or death Do not proceed beyond a WARNING notice until the indi cated conditions are fully understood and met Agilent L7222 Coaxial Transfer Switch Operating and Service Manual WEEE Compliance WEEE Compliance This product complies with the WEEE Directive 2002 96 EC marking requirements The affixed label indicates that you must not discard this electrical electronic product in domestic household waste Product Category With reference to the equipment types in the WEEE Directive ME Annex J this product is classed as a Monitoring and Control Instrumentation product Do not dispose in domestic household waste To return unwanted products contact your local Agilent office or see www agilent com for more information Printing Copies of Documentation from the Web To print copies of documentation from the Web download the PDF file from the Agilent web site Go to http www agilent com Enter the document s part number located on the title page in the Quick Search box Click GO Click on the hyperlink for the document Click the printer icon located in the tool bar Agilent L7222 Coaxial Transfer Switch Operating and iii Service Manual Contacting Agilent Americas Asia Pacific amp Japan Contacting Agilent Americas Asia Pacific amp Japan
9. cifications Table6 RF Specifications for L7222C Coaxial Transfer Switch Agilent Model Number L7222C Frequency Range DC to 26 5 GHz Insertion Loss 0 2 dB 0 025 x Freq GHz Isolation 110 dB 2 0 x Freq GHz SWR lt 1 1 DC to 2 GHz lt 1 15 2 to 4 GHz lt 1 25 4 to 12 4 GHz lt 1 40 12 4 to 20 GHz lt 1 65 20 to 26 5 GHz Repeatability lt 0 03 dB typical Characteristics 50 Connectors SMA f Agilent L7222C Coaxial Transfer Switch Operating and 9 Service Manual Specifications Table 7 Switch Drive Specifications for L7222C Coaxial Transfer Switch Min Nominal Max Unit Supply Voltage Vcc 20 24 32 V Supply Current Icc 200 mA Supply Current quiescent 25 50 mA 1 Switching Pulse width gt 15 ms Vcc 24 VDC Table 8 TTL Drive Specifications for L7222C Coaxial Transfer Switch Option T24 Min Nominal Max Unit High level input 3 7 V Low level input 0 8 V 1 1 4 mA Max high input current 1 Vcc Max Vinput 3 85 Vdc Supplement Specifications Cold Switching Figure 5 illustrates the maximum incident CW power cold switching from 100 MHz to 18 GHz The reference conditions are as below Cold switching only NO hot switching Ambient temperature of 75 C or less Sea level 0 88 derating 15 000 feet Low VSWR 1 2 See Figure 6 for derating above 1 2 VSWR 10 Agilent L7222C Coaxial Transfer Switch Operating and Ser
10. ction 1 14 Inspect the shipping container for damage If the shipping container or cushioning material is damaged it should be kept until the contents of the shipment have been checked for completeness and the instrument has been checked both mechanically and electrically Check for mechanical damage such as scratches or dents Procedures for checking electrical performance are given under Operator s Check or Performance Tests If the contents are incomplete if there is mechanical damage or defect or if the instrument does not pass the electrical performance test contact the nearest Agilent Technologies Sales and Service office Refer to the Service and Support information in the front matter of this manual Agilent Technologies will arrange for repair or replacement of the damaged or defective equipment Keep the shipping materials for the carrier s inspection If you are returning the instrument under warranty or for service repackaging the instrument requires original shipping containers and materials or their equivalents Agilent Technologies can provide packaging materials identical to the original materials Refer to Service and Support information in the front matter of this manual for the Agilent Technologies nearest you Attach a tag indicating the type of service required return address model number and serial number Mark the container FRAGILE to insure careful handling In any correspondence refer to the
11. e and or software described in this document are furnished under a license and may be used or copied only in accor dance with the terms of such license Restricted Rights Legend If software is for use in the performance of a U S Government prime contract or subcon tract Software is delivered and licensed as Commercial computer software as defined in DFAR 252 227 7014 June 1995 oras a commercial item as defined in FAR 2 101 a or as Restricted computer soft ware as defined in FAR 52 227 19 June 1987 or any equivalent agency regulation orcontract clause Use duplication or dis closure of Software is subject to Agilent Technologies standard commercial license terms and non DOD Departments and Agencies of the U S Government will receive no greater than Restricted Rights as defined in FAR 52 227 19 c 1 2 June 1987 U S Government users will receive no greater than Limited Rights as defined in FAR 52 227 14 June 1987 or DFAR 252 227 7015 b 2 November 1995 as applicable in any technical data Safety Notices CAUTION A CAUTION notice denotes a hazard It calls attention to an operating procedure prac tice or the like that if not correctly per formed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met WARNING A WARNING notice denotes a hazard It
12. ected to pin 1 but requires that pin 9 be grounded if pulse drive is used and continuous indicators operation is desired If pin 9 is not grounded the position indicators will function while the appropriate drive has ground applied Pin number Function lt lt 2 Common oo lt 4 Position A P 6 Position B Figure 4 Pin Function Diagram for Indicator Agilent L7222C Coaxial Transfer Switch Operating and 7 Service Manual Specifications Specifications Specifications refer to the performance standards or limits against which the L7222C coaxial transfer switch is tested Typical characteristics are included for additional information only and they are not specifications These are denoted as typical nominal or approximate and are printed in italics Table 4 General Specifications for L7222C Coaxial Transfer Switch Agilent Model Number L7222C Maximum power rating Switching IW CW Non switching 50W Pk not to exceed 1 W average Life 2 million cycles minimum Switching Speed 15 ms 1 Hot switching For cold switching see supplement specifications on page 9 Table 5 Indicator Specifications for L7222C Coaxial Transfer Switch Agilent Model Number L7222C Maximum withstand voltage 60 V Maximum current capacity 100 mA Maximum ON resistance 50 Maximum OFF resistance 1GQ 8 Agilent L7222C Coaxial Transfer Switch Operating and Service Manual Spe
13. his switch increases system uptime and lowers the cost of ownership by reducing calibration cycles and switch maintenance Opto electronic interrupts and indicators improve reliability and extend the life of the switch by eliminating DC circuit contact failures characteristic of conventional electromechanical switches The L7222C have circuits that interrupt the current to all the solenoids once switching is complete and offer independent indicators that are controlled by optical interrupts These indicators provide a closed path between the indicator common pin and the corresponding sense pin of the selected path 24 VDC 1 on Gnd 9 Control DriveA 3 G 4 Control F Input Drive B 5 G 4 circuit Va TTL Drive A 7 TTL Drive B 8 G a 4 P Position A Position B a e 1 2 2 3 ad 3 4 1 4 P4 4 4 2 9 A Com B di 1 O O 2 Indicators i gs a Pd 4 3 Figure 2 Agilent L7222C Coaxial Transfer Switch Schematic 2 Agilent L7222C Coaxial Transfer Switch Operating and Service Manual General Information Driving the Switch There are two positions for the L7222C coaxial transfer switch See Figure 3 Position A has RF Port 1 connected to RF Port 2 and RF Port 3 connected to RF Port 4 Position B has RF Port 2 connected to RF Port 3 and RF Port 1 connected to RF Port 4 Either switch can be driven with a standard grounding drive contr
14. instrument by model number and serial number Agilent L7222C Coaxial Transfer Switch Operating and Service Manual Operator s Check CAUTION Operating Instruction Operating Instruction The operator s check is supplied to allow the operator to make a quick check of the coaxial transfer switch prior to use or if a failure is suspected ESD exceeding the level specified in Table 9 or RF power applied is greater than the maximum specified as in Table 4 may cause permanent damage to the device Description The coaxial transfer switch is connected to a network analyzer configured for the s parameter measurement The network analyzer may be set to sweep over the whole or selected frequency range of the switch to be verified The S parameters measurement is the best way to determine if the switch is working properly NETWORK ANALYZER D000 0000 POWER SUPPLY Agilent Transfer Switch Figure 8 Connection to Perform Quick Check Agilent L7222C Coaxial Transfer Switch Operating and 15 Service Manual Operating Instruction Quick Check Procedure 1 16 Connect Port 1 and Port 2 of the network analyzer to switch s Port 1 and Port 2 respectively Refering to Table 2 standard drive or Table 3 TTL drive apply appropriate drive voltage to ensure switch is in position A path 1 connected to path 2 path 3 connected to path 4 Measure S11 S21 and 22 and verify against specifications in Table
15. ol with or without a separate ground Single line or Dual line TTL control are also available The switch operates in a break before make mode Table 2 Standard Drive Control RF path Standard drive voltage Drive A Drive B Pin 3 Pin 5 Position A Ground Open Position B Open Ground Table 3 TTL Drive Control RF path Single line TTL SV CMOS drive Dual line TTL SV CMOS drive voltage voltage TTL Drive A TTL Drive B TTL Drive A TTL Drive B Pin 7 Pin 8 Pin 7 Pin 8 Position A High High High Low Position B Low High Low High Standard Option 100 1 2 ous 4 0 1to2 3 Drive A t 3104 4 Ind vu WEIN 6 Ind B Y Y Position B i NIE Cini z 1 ot 9 Comm Gnd 4 3 NOTE RF Port 1 is located directly behind the 10 pin ribbon cable connector a b Figure 3 a RF Port Connections and b Drive Connections Agilent L7222C Coaxial Transfer Switch Operating and 3 Service Manual Standard Drive NOTE NOTE Single Line TTL Drive NOTE General Information Connect pin 1 to supply voltage 20 Vdc to 32 Vdc and pin 9 to ground See Figure 3 for connection diagram and Table 2 for standard drive control Pin 9 does not need to be grounded for the switch to operate in standard drive mode If pin 9 is not grounded the position indicators will only function while the appropriate drive has ground applied Therefore if a pul
16. ound See Figure 3 for connection diagram and Table 3 for TTL drive control For TTL drive pin 9 must be grounded In addition to the quiescent current supplying the electronic position sensing circuitry the drive current flows out of pin 9 during switching when using TTL drive Select position A by applying TTL High to pin 7 and TTL Low to pin 8 Select position B by applying TTL Low to pin 7 and TTL High to pin 8 After the RF path is switched and latched the drive current is interrupted by the electronic position sensing circuitry Pulsed control is not necessary but Agilent L7222C Coaxial Transfer Switch Operating and 5 Service Manual General Information if implemented the pulse width must be 15 ms minimum to ensure that the switch is fully latched 6 Agilent L7222C Coaxial Transfer Switch Operating and Service Manual General Information Electronic Position Indicators The electronic position indicators consist of optically isolated solid state relays which are driven by photo electric sensors coupled to the mechanical position of the RF path s moving elements See Figure 4 The circuitry consists of acommon which can be connected to an output corresponding to either postition A or position B The solid state relays are configured for AC and or DC operation See Table 5 for indicator specifications The electronic position indicators require that the supply 20 to 32 VDC be conn
17. plicable law Agilent disclaims all war ranties either express or implied with regard to this manual and any information contained herein including but not limited to the implied warranties of merchantability and fitness for a particular purpose Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing use or performance of this document or of any information con tained herein Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms the warranty terms in the separate agree ment shall control Limitation of Warranty The foregoing war ranty shall not apply to defects resulting from the improper or inadequate mainte nance by the Buyer Buyer supplied soft ware or interfacing unauthorized modification or misuse operation outside of the environmental specifications for the product or improper site preparation or maintenance NO OTHER WARRANTY IS EXPRESSED OR IMPLIED AGILENT SPECIFICALLY DIS CLAIMS THE IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Exclusive Remedies THE REMEDIES PRO VIDED HEREIN ARE THE BUYER S SOLE AND EXCLUSIVE REMEDIES AGILENT SHALL NOT BE LIABLE FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CON SEQUENTIAL DAMAGES WHETHER BASED ON CONTRACT TORT OR ANY OTHER LEGAL THEORY Technology Licenses The hardwar
18. se drive is used and continuous indicator operation is required pin 9 must be grounded Select position A by applying ground to pin 3 Select position B by applying ground to pin 5 After the RF path is switched and latched the drive current is interrupted by the electronic position sensing circuitry Pulsed control is not necessary but if implemented the pulse width must be 15 ms minimum to ensure that the switch is fully latched Connect pin 1 to supply voltage 20 Vdc to 32 Vdc and pin 9 to ground See Figure 3 for connection diagram and Table 3 for TTL drive control For TTL drive pin 9 must be grounded In addition to the quiescent current supplying the electronic position sensing circuitry the drive current flows out of pin 9 during switching when using TTL drive 4 Agilent L7222C Coaxial Transfer Switch Operating and Service Manual NOTE Dual Line TTL Drive NOTE NOTE General Information Select position A by applying TTL High to pin 7 and TTL High to pin 8 Select position B by applying TTL Low to pin 7 and TTL High to pin 8 After the RF path is switched and latched the drive current is interrupted by the electronic position sensing circuitry Pulsed control is not necessary but if implemented the pulse witdth must be 15 ms minimum to ensure that the switch is fully latched Connect pin 1 to supply voltage 20 Vdc to 32 Vdc and pin 9 to gr
19. t recommended for repair as most components are not easily removed The connectors particularly the connector faces must be kept clean For instruction on connecting and care of your connectors refer to the Microwave Connector Care Quick Reference Card 08510 90360 Agilent L7222C Coaxial Transfer Switch Operating and 17 Service Manual Service Instructions 18 Agilent L7222C Coaxial Transfer Switch Operating and Service Manual
20. vice Manual MAX incident CW power cold switching vs frequency Specifications CW power Watts Frequency GHz Figure 5 Maximum Incident Power Cold Switching vs Frequency Power derating factor versus VSWR amp og M S 7 c S 08 e D 07 m qo doo cGNU dE 58559 eo ao 06 0 5 1 1 5 2 2 5 VSWR 1 Figure 6 Power Derating Factor vs VSWR Agilent L7222C Coaxial Transfer Switch Operating and Service Manual 11 Environmental Specifications Environmental Specifications The L series multiport coaxial switches are designed to fully comply with Agilent Technologies product operating environmental specifications as shown in Table 9 Table9 L7222C Coaxial Transfer Switch Environmental Specifications Temperature Operating 25 C to 75 C Storage 55 C to 85 C Cycling 55 C to 85 C 10 cycles per MIL STD 202F Method 107D Condition A modified Humidity Operating 95 RH at 65 C 10 days per MIL STD 202F Method 106E Shock Half sine 500 G 0 5 ms 3 drops direction 18 total Operating 50 G 6 ms 18 total Vibration Operating 7 G rms 5 to 2000 Hz at 0 25 in p p Survival 20 G rms 20 to 2000 Hz at 0 06 in p p 4 min cycle 4 cycles axis Random 2 41 G rms 10 minutes axis piHtade 15 240 meters 50 000 feet per MIL STD 202F Method 105C Storage Condition B ESD Immunity Direct discharge Air discharge