Home

here

image

Contents

1. Envi Heater Hardwired Cordset Wire Color Guide Envi Heater Hardwired Models Only L1 Black Wire Live GROUND WIRE G Green Wire Ground SUPPLY VOLTAGE see note above L2 White Wire Live Page 4 economical safe simple HARDWIRING INSTRUCTIONS CONT STEP 1 Determine the best wall mounting location of the Envi Heater inaroom If the proper electrical wiring and wall box already Knock out Holes exists at a suitable height on the wall then choose a suitable 1 5in 3 8cm knock out hole on the back of the heater 4 holes to choose apart from and position the heater on the wall so that the knockout hole lines up with the electrical wall box If new electrical wiring and a wall box is to be installed then it is best to mount the heater first and then determine the cor responding location on the wall for the new electrical wiring wall box When installing a new wall box ensure it is at a proper location on the wall to allow the heater to remain at 6 to 8 15 to 20cm or so above the finished floor level gS ea Cordset pice SSEEEPEEEPUEETE Turn the power OFF at the main electrical panel to the heater circuit Run the electrical wiring and secure it properly to the electrical box per applicable electrical and building codes NOTE Although the Envi Heater has a low amperage draw eg 4amps 120v the electrical code requires a minimum sup
2. PLEASE DO NOT RETURN TO RETAIL STORE BEFORE YOU CALL THE ENVI HELP DESK We are here to help you with any questions you might have Before you call for help though please read this manual as it contains instructions to help you to install operate and maintain your heater properly If you receive a damaged heater please immediately contact the dealer that sold you your Envi heater If you still need help please call the Envi Help desk in the USA Canada Toll Free 800 807 0107 or if calling from outside the USA call 1 281 516 1577 a FEATURES amp BENEFITS Made in the USA to ISO 9001 Quality Certification 3 year Warranty NEW Adjustable Temperature controlling with simple operation NEW Wall Sens Technology safety cut off feature NEW Convenient cordset storage inside the heater NEW Now available in hardwired models Economical high efficiency technology 4 cents per hour based on US National Average Turn down the central heat and use envi heaters where needed J Eliminates hot and cold spots where central heat is ineffective Ultra Safe cool to the touch 90 F 32 C can leave on unattended 24 7 Healthy won t blow dust and allergens around or dry out the air Sleep Friendly fanless technology silent operation Auto dimming of power light for dark bedrooms Easy Installation no drill required for mounting to wall Slim space saving design only 2in 5cm th
3. switch or timer Consult the instructions for each of these control devices for specific wiring instructions The Envi Heater can also be wired as multiple heaters on the same circuit or controller For these Multi Heater Hardwiring instructions please consult the installation page of the website www eheat com The Envi Heater can also be hardwired to a 24volt thermostat using a 24v relay Please consult a certified electrician and ensure that all electrical work is done in accordance with applicable electrical and building codes CAUTION To prevent short circuits and electrical shocks turn the power off at the main electrical panel before attempting the hardwiring installation or any repairs If the internal power cable cordset is damaged it must be replaced by the manufacturer NOTE This hardwired heater must be connected to the correct voltage circuit according to its model designation ie HW1012 120volts HW1022 220volts and HW1023 230volts Disconnect the power supply before making wiring connec tions to prevent electrical shock and equipment damage WIRING SCHEMATIC NOTE The following wiring schematic is for a single Envi Heater installation to the applicable ac mains supply circuit and as sumes that the there are no external controls being wired into the unit For wiring of external controls thermostat switches or timers please consult the website www eheat com for examples of external control wiring instructions a a
4. the bottom of the heater a maxi mum of 18 46cm from the floor 2 The 475 Watt Envi heater is designed to heat rooms 130 to 150 ft feet in size 12m to14m7 This equates to a 10ft x 14ft room size 3 x 4meters Of course this will vary depending on a number of factor including outdoor temperature room insulation room draftiness room objects etc 3 For optimal performance in a room close all windows and doors and for first time use leave on for 48 72 hrs This will N Page 6 economical safe simple OPERATING INSTRUCTIONS CONT a N allow the room to reach equilibrium temperature and help to confine the heat to the area that needs it most 4 To save energy and to reduce your heating bills place the heater in a room or area that needs extra heat instead of rais ing the thermostat on your central heating system This heater will function very well as both a sole source of heat or as an additional heating source that can easily maintain the temperature in most rooms and attached bathrooms if the correct number of Envi heaters are installed There is no need to increase the heat in the entire house when you only need comfort in the room in which you are currently located 5 We highly recommend that our customers weatherize their home to further reduce their heating bills Simple tasks such as replacing weather stripping around doors and windows caulking door and window seams sealing attics and basements proper
5. the power to the heater by pressing the on off button If the wiring has been performed correctly then the power indicator light will glow red Page 5 economical safe simple OPERATING INSTRUCTIONS p HOW IT WORKS The Envi Heater is designed with innovative Stack Convection Technology that effectively heats a room with minimal energy The Envi s inner chamber simulates stacks of varying height which boost airflow through the heater to achieve maximum efficiency The end result is enhanced airflow at safe air temperature all without the use of a fan The Envi heater will provide consistent comfortable silent heat without drying out the air or leaving cold spots in the room OVERHEAT SAFETY FEATURE This heater is equipped with an overheat safety feature When the heaters internal components reach a certain temperature that could cause overheating and a possible fire the heater will automatically shut off To reset the heater unplug the heater power cord from the electrical outlet for 10 minutes After 10 minutes plug the heater into the electrical outlet and turn on us ing the heater s on off switch located on the front of the unit WALL SENS SAFETY FEATURE In addition to the overheat safety cut off the Envi Heater is now equipped with an additional layer of safety to give you greater peace of mind Wall Sens technology means that in the event that the Envi heater is ever removed from the wall power
6. will be immediately cut to the heater This of course means that the heater will not work if it is simply removed from its packaging and plugged into a wall outlet It must be mounted properly safely and then plugged in or hardwired in order for it to be begin to heat GROUNDING Plug in models of the envi heater are for use on standard electrical circuits eg 120v for USA Canada The cord has a three blade grounding plug An adapter can be obtained at most hardware or electrical stores for connecting three blade grounding type plugs to two slot receptacles The grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box The adapter should not be used if a three slot grounded receptacle is available DO NOT DEFEAT THE SAFETY PURPOSE OF THE GROUNDED PLUG __ OPERATING INSTRUCTIONS a 1 Install the heater on a firm level wall and plug the power cord into a grounded power outlet or hardwire it if applicable The heater will only operate when it is properly attached to the mounting clips Be sure to mount in upright position with the thermostat knob on the top of the heater Power 2 Once the heater is connected press the front on off power ae switch and the POWER INDICATION LIGHT will glow red Fig 5 3 The Envi Heater is equipped with a built in thermostat which is adjusted with a dial at the top of the heater Adjust the room aon temperature by turning the
7. AND IN NO EVENT SHALL CONSERVETEC INTERNATIONALS LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT Note This warranty does not renew or extend with a replacement product All warranties are from the date of the original product purchase This warranty covers only new products purchased from our authorized dealers or retailers It does not cover used sal vaged or refurbished products As some states do not allow the limitation or exclusion of incidental or consequential damages or do not allow limitation on implied warranties the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state For Technical Support and Warranty Service Write To Conservetec International 22955 Tomball Parkway Ste 17 Tomball TX 77375 USA conservetec INNOVATIVE PRODUCT TECHNOLOGY Email contact conservetec com Call 1 281 516 1577 Online www eheat com or www envi heat com Registration Details Store Name Location Date Purchased Serial Number Serial is found on back of unit S Page 8
8. THERMOSTAT DIAL clockwise to Switch increase the room temperature If the area becomes too warm J rotate the THERMOSTAT DIAL counter clockwise until you reach a point where the temperature is more comfortable Fig 5 4 Once you have chosen the desired setting the thermostat will maintain a constant temperature NOTE Models with no thermostat have no temperature control and will stay on until the heater is powered off 5 The heater is equipped with an innovative auto dimming feature that dims the power indication light for light sleeper in darkened bedrooms The heater automatically detects when the light level in a room drops and then dims the power light 6 The plug in cordset of the Envi heater can be stored inside the bottom access door Determine how much cordset you require to extend out of the heater Remove the heater from the wall and remove the bottom access door Carefully push the excess cordset inside the heater and replace the bottom access door Re install the heater to the wall and plug in the cordset to continue using your heater For more information please visit the installation web page of www eheat com OPTIMAL OPERATING CONDITIONS To get the most out of your Envi Heater please follow these helpful hints 1 For optimal performance mount the heater on an interior wall with the bottom of the heater 6 to 8 15 to 20cm from the floor For smaller rooms this can be increased with little detriment however try to keep
9. crew driver Fig 2 If a stud is in the way 475 Watt Envi Wall Mounted Heater do not use the wall anchor supplied just screw directly e Owners Manual into the stud The anchor supplied is designed for dry e 2x Mounting Clips wall applications only For masonry walls please use 3x Hollow Wall Anchor 3 x 8 Mounting Screws appropriate masonry wall anchors not supplied e Grommet to protect Knockout hole edges supplied with hardwired models only e Wall Anchor Marking Template The template holes are marked on the outer edge of the packaging insert frame Fig 1 Note the supplied mounting kit is for installation into drywall sheetrock only J WALL MOUNTING Remove the heater mounting kit and packaging insert frame from the box Keep the packaging materials for future use 1 Unwrap and flatten the sides of the packaging insert frame and stand the insert template on the floor The sides of the insert template have pre punched holes pre set to give a heater mounting height of 6 or 8 15 or 20cm from the bottom of the heater to the floor Choose either mounting height and mark three hole locations on the wall see Fig 1 3 Screw the two mounting clips with arrow pointing upward into the top two anchor locations and secure firmly to the wall anchors using the provided screws see Fig 3 DO NOT overtighten There should be a gap The top two hole locations are for the mounting clip
10. front of the panel is lit If not press the on off power switch 3 Check if the power cord is plugged into an electrical outlet if not plug it in If the heater has been hardwired consult an electrician to check that all connections have been made correctly 5 Check if electricity to the circuit is working This can be found in your breaker box check to make sure the breaker is in the m on position SPECIFICATIONS N PRODUCT SPECIFICATIONS amp USE Power Rating 475 Watts All Models Volt amp Amp Rating HH HW1012 Models 3 95 Amps 120volts HH HW1022 Models 2 16 Amps 220volts HH HW1023 Models 2 06 Amps 230volts Unit Size 19 3in W x 2 2in D x 22 2in H 49 0cm W x 5 6cm D x 56 4cm H Net Weight 10 Ibs 4 5 kg Packaged Wt 12 Ibs 5 5 kg Color Luxury White Other colors may be available check with Manufacturer for availability Safety Listings Intertek ETL Listing 3189101 conforming to lj Underwriters Laboratory UL 2021 Fixed and Location Dedicated Electric Room Heater c us Canadian Standards Association for Electric Air Heaters CSA C22 2 No 46 M1988 Commercial Use The Envi is a fixed wall heater not portable and operates with low surface temperatures It is con sidered suitable for commercial use in Elderly Care Childcare corporate and government facilities Ne J Page 7 economical safe simple WARRANTY ie 1 Three Year Limited Warranty C
11. in Long life No moving parts crack resistance surfaces Environmentally friendly low power consumption A IMPORTANT INSTRUCTIONS THIS HEATER IS EQUIPPED WITH AN ADVANCED SAFETY FEATURE THAT PREVENTS IT FROM BEING TURNED ON UNLESS IT IS MOUNTED ON THE WALL WITH THE SUPPLIED WALL ANCHOR CLIPS When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following 1 Read all instructions before installing or using this heater 10 where gasoline paint explosive and or flammable liquids are used or stored Keep unit away from heated surfaces and open flames Use this heater only as described in this manual Any other 2 Extreme caution is necessary when any heater is used by or use not recommended by the manufacturer may cause fire near children or invalids or when the heater is left operat electric shock or injury to persons ing and unattended 11 Use only for the intended household or office uses as de 3 Do not operate any heater after it malfunctions Discon scribed in this manual Any other use not recommended by nect power at service panel and have heater inspected by the manufacturer may cause fire electric shock or injury to a reputable electrician before reusing persons The use of non recommended attachments sold 4 For plug in heaters to disconnect push power button to by unauthorized dealers may cau
12. ly and adding more insulation to your walls and ceiling will drastically reduce home heating costs CARE amp MAINTENANCE INSTRUCTIONS CLEANING 1 Unplug the unit and let it cool completely 2 To remove dust from the Envi heater use a soft cloth 3 To remove marks or stains from the heater the front outer shell can be cleaned with a soft damp cloth You may use a mild detergent if necessary After cleaning dry the unit with a soft cloth CAUTION Do not let liquid enter the heater 4 Do not use alcohol acetone based cleaners gasoline abrasive powders furniture polish or abrasive or rough cloths or brushes to clean the front of the heater This may cause damage or deterioration to the surface 5 Do not immerse the heater in water 6 Wait until the unit is completely dry before using again STORAGE Store the heater in a cool dry location when not in use However the Envi Heater is a slim attractive wall mounted heater than can be left mounted on the wall year round S of TROUBLE SHOOTING If the heater will not operate please check the following before seeking repair or service 1 Check that the heater is correctly installed against the wall using the two supplied mounting clips The Envi Heater will not operate unless it is installed correctly due to the inclusion of a new safety feature called Wall Sens Technology 2 Check if the heater is set to ON by confirming the light on the
13. onservetec International warrants the accompanying Envi Heater to be free of defects in material and workmanship for the applications specified in its operation instructions for a period of THREE 3 years from the date of original purchase in the United States If the unit exhibits a defect in normal use Conservetec International will at its option either repair or replace it free of charge within a reasonable time after the unit is returned during the warranty period As a condition to any warranty service obligation the consumer must present a copy of the original purchase invoice THESE WARRANTIES DO NOT APPLY FOR e Damage accidental or otherwise to the unit while in the possession of a consumer not caused by a defect in material or workmanship e Damage caused by improper installation or connection to incorrect supply voltage e Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions e Damage to the finish of the case or other appearance parts caused by wear e Damage caused by repairs or alterations of the unit by anyone other than those authorized by Conservetec Interna tional e Freight and Insurance cost for the warranty service ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO A THREE YEAR DURA TION OF THIS EXPRESS LIMITED WARRANTY CONSERVETEC INTERNATIONAL DISCLAIMS ANY LIABILITY FOR CONSEQUEN TIAL OR INCIDENTAL DAMAGES
14. ply wire gauge to be used so make sure you check first STEP 2 Mount the Envi Heater using the two mounting clips per the Wall Mounting Instructions see page 2 asc corse contained herein to ensure that the heater is at the proper location on the wall and that the knockout hole is Twist to remove aligned with the supply wiring STEP 3 Remove the Envi heater from the wall to continue with the hardwiring steps If not already done at Step 1 remove a knock out hole a screw driver can be used on the back of the heater and install the supplied protection grommet into the knockout hole Remove the bottom access door and pull the supply wiring into the Envi Heater and out through the bottom access door Pull the Envi cordset wiring through bottom access door opening and using wire nuts connect the heater wires L1 live L2 neutral and G ground to the corresponding supply wires per the wiring schematic above Push the connected wiring nuts inside the opening and re attach the bottom access door STEP 4 Re mount the Envi Heater to the wall ensuring all three mounting screws are used Ensure that any wiring is pushed inside the wall electrical box and is not trapped between the Envi Heater and the wall STEP 5 Turn the power ON at the main electrical panel to the heater circuit Check that there are no obvious problems with the hard wiring to the heater such as crackling noises sparks or smoke and if everything is okay turn on
15. s behind the mounting clip to hang the heater on and the bottom location is for a third mounting screw hidden inside the bottom access door as described in step 5 below P Fig 3 Fig 1 Mounting Clip Hole Locations Choose 8 Height or 6 Height 15 or 20cm 17 3 4 451mm Bottom Mounting Hole Location Choose 8 Height or 6 Height 15 or 20cm 4 Remove the bottom access door to gain access to the bottom mounting hole Fig 4 Page 3 economical safe simple MOUNTING INSTRUCTIONS CONT 5 Install heater on mounting clips making sure to press down 6 Install the third screw inside the bottom access door area firmly on the heater to ensure secure fit You will hear it Fig 6 Replace the door Please note for clarity the cord snap into place Fig 5 set is not shown exiting the heater For additional information visit www eheat com 4 Fig 6 HARDWIRING INSTRUCTIONS The Envi Heater is available in some regions as a hardwired model HW1012T HW1022T HW1023T with built in thermostat and HW1012N HW1022N HW1023N with no built in thermostat instead a cover plate is in its place The Envi Heater can be hardwired direct to a mains supply branch circuit or it can be hardwired to a line voltage external ther mostat of the same voltage as the heater eg 120v or to an external
16. se hazards turn heater OFF the power indicator light will turn off 12 Do not use outdoors then remove plug from outlet Pull firmly on the plug do 13 This heater is intended for use as a WALL MOUNTED heater not unplug by pulling on the cord only Failure to properly secure the heater to a flat level 5 Connect to properly grounded outlets only and vertical wall may result in heater malfunction and or 6 For hardwired heaters to disconnect turn controls to off property damage and turn off power to heater circuit at main disconnect 14 This heater will not operate power will not be supplied panel or operate internal disconnect switch if provided unless it is attached to a wall using the supplied wall 7 Do not insert or allow foreign objects to enter any ventila mounting clips tion or exhaust opening as this may cause an electric shock 15 DO NOT attempt to repair or replace any electrical or or fire or damage the heater mechanical functions on this unit Doing so will void your 8 To prevent a possible fire do not block air intakes or ex warranty The inside of the unit contains no user service haust in any manner able parts Qualified personnel should perform all servicing 9 A heater has hot or arcing parts inside Do not use in areas only SAVE THESE INSTRUCTIONS Page 2 economical safe simple INSTALLATION INSTRUCTIONS D 2 Screw the anchors into wall at the three marked loca WHAT IS IN THE BOX tions using a s
17. wall mounted HEATER OWNERS MANUAL MODELS COVERED BY THIS MANUAL TABLE OF CONTENTS 475 Watt 120 Volt Models If you need Help p2 HH1012T Plug In with Thermostat Features and Benefits p2 HH1012N Plug In No Thermostat Important Instructions p2 HW1012T Hardwired with Thermostat l l What s in the box p3 HW1012N Hardwired No Thermostat Wall Mounting Instructions p3 475 Watt 220 Volt Models Hardwiring Instructions p4 HH1022T Plug In with Thermostat Operating Instructions p6 HH1022N Plug In No Thermostat How the Envi Works p6 HW1022T Hardwired with Thermostat Unique Safety Features p6 HW1022N Hardwired No Thermostat Grounding p6 475 Watt 230 Volt Models Optimal Operating Conditions p6 HH1023T Plug In with Thermostat Maintenance p7 HH1023N Plug In No Thermostat Storage p7 HW1023T Hardwired with Thermostat Troubleshooting p7 HW1023N Hardwired No Thermostat Specifications amp Uses p7 Warranty p8 DCN 620013 economical safe simple economical safe simple fo THANK YOU FOR CHOOSING THE ENVI HEATER Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects instal lation and care of your new Envi Heater For your own records please attach a copy of your sales receipt to this manual Also write the store name location date purchased and serial number in the space provided on the warranty page MISSING PARTS HAVE QUESTIONS OR NEED HELP