Home
WOOD FIRE OWNERS MANUAL
Contents
1. If the wood fire is refuelled and left on a low setting allowing it to smoulder the firebox will fill with smoke and combustible gasses The fuel will eventually ignite and when it does so the build up of gasses will cause a pressurisation forcing smoke into the room This is usually a problem when the wind is coming from one particular direction and requires an experienced installer to remedy by either extending your flue height or fitting an anti down draft flue cowl Ensure that after refuelling heat output control is on HI before setting it to LOW This raises the temperature inside the firebox that will create high flue draft 13 Problem Reason for Problem Solution Poor performance of the fire or Smoke entering into room due to extreme negative pressure in the house This is when the air circulates down from the chimney towards the interior of the house which is at negative pressure Energy efficiency practices and new building code rules are making our houses more and more airtight This makes the house s energy efficient but also makes them more sensitive to negative pressure when air is exhausted from the house This can be because of large extraction fans which cause extreme negative pressure in the house when they are operating This negative pressure works against flue system draft In severe cases the negative pressure in the house overcomes the flue system draft and the
2. L Slide the control in the direction of the wide end of the wedge to increase the heat output and toward the narrow end to decrease it Shutting a high fire down rapidly by starving it of air will result in heavy particulates of unburned fuel which are undesirable emissions For this reason turn down heat output control from Hi to Low position gradually Note The lever on some models is marked H for high fire and L for low fire EXTENDED BURNING Our Fires will burn for a long period To achieve this level the embers and load the fire wood lying front to back except Atlanta Bay NZ model which was emission tested with fuel loading from side to side Use large logs and ensure that there are gaps between the fire wood to allow air to reach all the pieces of wood Open the air inlet fully for 15 to 20 minutes When the fire is burning fiercely reduce the air intake in stages to the minimum opening NEVER LET THE FIRE SMOULDER Smoldering is not good for the environment It will create creosote built up in the fire flue and will increase risk of flue fires or flue blockages FAN OPERATION Inbuilt Wood fires SHOULD NOT be operated on maximum heat with very dry softwood unless the fan is operating On freestanding woodfires the optional fan MUST only be operated when the heat output control air slide on the fire is set on HIGH Not all models have a fan option ESSENTIAL ADVICE Correct installation the use of only DRY wood a
3. The tube will have either one or two removable angle pins to prevent it from moving endways and falling out If there is one removable pin one end of the tube will have a welded on locating pin To remove the tube simply withdraw the angle pin s from the tube move the tube sideways until one end can be swung down from its locating hole in the firebox side casting and then move it sideways in the other direction to disengage it completely from the firebox When re fitting the tube ensure that the small air holes will discharge generally toward the lower front of the firebox rotating the tube until the welded on locating pin or the angle 9 pin will engage in the slot in the cast iron firebox side casting to maintain the correct angular position of the tube Replace the angle pin at the other end of the tube Removable R Clip type The air tube is secured to the left hand side of the fire box with a R Clip Remove the R Clip and move the tube to the right remove the tube from the left hand side of the fire box first FIREBOX SIDE CASTING SECONDARY AIR TUBE WELDED ANGLE PIN FIREBOX TOP BAFFLE The special top baffle material operates at very high temperature to ensure clean burning Take care not to knock and damage it For flue cleaning or baffle replacement the secondary air tube must first be removed as described above When replacing the baffle ensure that it is sitting on top of the supporting shelf a
4. WOOD FIRE OWNERS MANUAL WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage For assistance or additional information consult an authorized technician or your Wood Fire Dealer FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this appliance Installation and service must be performed by authorized personnel INSTALLATION OF YOUR WOODFIRE Please refer to the Installation Manual and Installation Specification Sheets specific for your model PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER REFERENCE Manufactured in New Zealand by Distributed in Australia by GLEN DIMPLEX AUSTRALASIA LIMITED GLEN DIMPLEX AUSTRALIA PTY LIMITED P O Box 58473 Botany Manukau 2163 Unit 2 21 Lionel Road Mount Waverley Victoria 3149 Ph 0800 666 2824 Ph 1 300 556 816 Fax 09 274 8472 Fax 1 800 058 900 Email sales glendimplex co nz Email sales glendimplex com au Web www glendimplex co nz Web www glendimplex com au 30 March 2012 Part No 593286 CONTENTS OPERATING INSTRUCTIONS BEFORE EACH HEATING SEASON FAN WIRING DIAGRAMS PROBLEM SOLVING WARRANTY REGISTRATION FORM WARRANTY TERMS amp CONDITIONS FOR ALL MODELS ds NM INTRODUCTION BASIC INFORMATION LIGHTING UP OS OPERATING HINTS SAFETY EN MAINTENANCE 9 N THIS MANUAL CONTAINS IMPORTANT INFORMATION PLEASE KEEP IT IN A SAFE PLACE FOR FUTURE REFERENCE
5. claim can be established by them Manufactured in New Zealand by Distributed in Australia by GLEN DIMPLEX AUSTRALASIA LTD GLEN DIMPLEX AUSTALIA PTY LTD P O Box 58473 Botany Unit 1 21 Lionel Road Mount Waverley Manukau 2163 Victoria 3149 Phone 0800 666 2824 Phone 1 300 556 816 Fax 09 274 8472 Fax 1800 058 900 Email sales glendimplex co nz Email sales glendimplex com au Web www glendimplex co nz Web www glendimplex com au 18
6. F2000 F3000 F3300C F7000 Atlanta HW Hestia HW 12 PROBLEM SOLVING Problem Reason for Problem Solution Dark dirty film door glass on Burning wet or green firewood OR Extended burn time on low setting OR Leaking door seal Ensure only dry seasoned wood is used Burn heater on high to burn off worst of dirty film Check door and glass seals and adjust door tightness Your Masport Dealer can help with this To remove dirty film try following 1 Burn on high for 30 minutes 2 Try to clean glass with damp news paper and ash when fire has completely cooled down Try using non caustic oven cleaner Tougher stains may need very careful scrapping with a razor blade Caution Do not scrub using steel products as it can leave scratch marks on the glass Bx en Creosote Build up Creosote is a tar like substance that builds up when the organic compounds in smoke condense onto cooler surfaces Creosote can build up over time and restrict the airflow of the flue and impair the performance of the wood heater The most effective way to control the creosote formation is to burn the woodstove on high regularly and never allow a fire to smoulder Occasional puffs of smoke entering the room while loading fuel There could be not enough flue draft due to insufficient flue height in relation to your roofline trees or other high obstacles near your home which can cause a down draft
7. INTRODUCTION In the interests of your safety most building regulatory Authorities in Australia and New Zealand require any wood fire installation to comply with Installation Standard AS NZS 2918 They may also have local requirements in addition to those in the Standard Check with your local Building Authority before commencing installation to find if you will require a Permit and whether there are extra requirements All our Wood fires have been tested to ensure that they will meet the appropriate safety Standard requirements if the instructions in this book and additional instructions supplied with the fire are followed As the safety and emissions performance can be affected by altering the appliance no modifications are allowed without written permission from the manufacturer Wood fire models covered by this manual have been tested to demonstrate compliance with current general emission requirements in Australia and New Zealand but some areas have stricter limits Only some of the models meet those limits so check before purchasing or installing a particular model In areas covered by stricter emission regulations 1 If a water heating device is permitted it must be factory fitted or be a genuine accessory retrofitted strictly in accordance with the instructions supplied by us 11 Coal must not be used as a fuel unless it is a multi fuel fire 111 Wood fuel must have a moisture content of less than 25 WE RECOMMEND THAT THE IN
8. blowing or vacuuming and reassemble in the reverse order If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard CLEANING THE FLUE This may be needed about once a year Check your House Fire Insurance or more frequently under adverse conditions Signs of creosote and soot build up are inadequate draught smoking when the door is opened and a dull thud when the outside of the flue is tapped A blocked flue can be cleaned only by sweeping DO NOT USE CHEMICAL CHIMNEY CLEANERS FLUE INSPECTION Check regularly that the flue is sound particularly the metal base of enameled flues BEFORE EACH HEATING SEASON To ensure continued safety check the condition of the following items the flue system particularly the flue sections nearest the firebox the firebox top baffle the air tube the firebox liners bricks and boards and the door gasket Replace parts only with genuine GLEN DIMPLEX spares TESTING YOUR WOOD When the wood fire is thoroughly warmed place one piece of split wood about 120mm 6 inches diameter parallel to the door on the bed of embers Keep the air control fully open and close the door If ignition of the piece of wood is 11 accomplished within 90 seconds from the time it was placed in the fire the wood is correctly dried If ignition takes longer the wood is damp If the wood hisses and water or vapour escapes from the en
9. covered under this warranty e Repair or replacement of parts e Labour costs relating to the Wood or Multi fuel Fire e Reasonable transport or travel costs Consumers may have additional rights under the Consumer Guarantees Act 1993 New Zealand or the Australian Trade Practices Act 1974 including the Australian Consumer Law Conditions This warranty does not apply and will be void where e The Wood or Multi fuel Fire is not installed in accordance with AS NZS2918 2001 or any building code or consent e The Wood or Multi fuel Fire is not installed by a qualified specialist installer e Any electrical work has not been carried out by a Registered Electrician e The Wood or Multi fuel Fire has been moved and reinstalled or has been modified in a manner that is not consistent with the Installation Guide or the Owner s Manual e The Wood or Multi fuel Fire has not been installed or operated according to the Installation Guide and the Owner s Manual e The Wood or Multi fuel Fire is acquired for business use in any way 17 What is not covered Wear and tear including wear and tear through normal use on Multi fuel fire grates and cast iron fire box liners Labour costs relating exclusively to components not manufactured by Glen Dimplex Damage caused by incorrect use or the burning of treated or painted wood driftwood or other fuels which are not recommended Travel costs for a distance greater than 50 km from the nearest approved M
10. with water is sufficient to clean and maintain the finish of the panels Household detergent may damage painted panels or give bad odors while running the fire ADJUSTING THE DOOR LATCH If the handle is front mounted the latch can be adjusted to overcome settling of the door gasket by transferring a washer to the outside of the door catch spindle If the handle is side mounted the latch is adjusted by rotating the door catch peg First undo the lock nut on the inside of the peg and then rotate the peg to the position where the cam portion gives the right locking pressure Hold the peg in this position re tighten the lock nut The hinge on all models can also be adjusted inward if necessary Move it in about a millimetre at top and bottom to maintain an even gasket pressure Serious leakage will require a new door seal HEAT OUTPUT CONTROL AIR SLIDE If the air slide does not move freely apply a small amount of heat resistant air slide lubricant available from Glen Dimplex CLEANING INSIDE If you wish to clean the flue or clear away creosote debris the internal components can be removed easily See below We recommend that you check the condition of all internal components at least once a season to make sure they are still serviceable SECONDARY AIR TUBE REMOVAL Tubes are fitted either with removable pin on right hand side or with an R clip on left hand side of the firebox Refer diagrams on next page Removable pin type
11. ARKING TESTED TO AS NZS 4013 ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITNG BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS NZS 4013 CAUTION Please ensure that only components approved by Glen Dimplex are used for the installation as substitutes may adversely affect performance and might nullify compliance with the requirements of AS NZS 2918 CAUTION Mixing of appliance or flue system components from different sources or modifying the dimensional specification of components may result in hazardous conditions Where such action is considered the manufacturer should be consulted in the first instance CAUTION Cracked broken components e g door glass makes the installation unsafe 4 OPERATING INSTRUCTIONS ALL MODELS BASIC INFORMATION DOOR HANDLE Front mounted handles To open the door Rotate the handle upward anti clockwise to the 1 o clock position To close the door Push the door toward the fire box using the handle and turn the handle clockwise to the 4 or 5 o clock position Side mounted handles To open the door Pull the lower part of the handle forward and upward To close the door Hold the handle up whilst closing the door Push the handle down to the vertical position to lock the door HEAT OUTPUT CONTROL AIR SLIDE This control has a sliding action It is clearly marked with a wedge shaped symbol or letters H and
12. E ABLE TO ENTER THE ROOM WHERE YOUR WOODFIRE IS INSTALLED YOU MAY HAVE TO LEAVE A DOOR SLIGHTLY OPEN AND PERHAPS A WINDOW ELSEWHERE IN THE HOUSE IF YOUR HOME IS OF MODERN AIRTIGHT CONSTRUCTION THIS IS PARTICULARLY IMPORTANT IF AN AIR EXTRACTION FAN IS OPERATING SOMEWHERE IN THE HOUSE LEAVING THE ROOM DOOR OPEN WILL HELP SPREAD WARMTH THROUGH THE REST OF YOUR HOME 7 SAFETY e Always keep children well away from the wood fire when it is alight e Supervise young children to ensure they do not play with the appliance e This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety e If the supply cord is damaged it must be replaced by the manufacturer its service agent or a suitably qualified person in order to avoid electrical hazard e Ensure that the electrical plug is accessible after installation The heater must not be located immediately below an electrical socket e Do not put furniture clothing firewood or other combustibles near the wood fire ALWAYS KEEP CLOTHING FIREWOOD FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS A SAFE DISTANCE FROM THE FIRE DO NOT LEAVE CHILDREN UN ATTENDED NEAR A LIGHTED FIRE e Do not leave the fire unattended with the glass door open or in case
13. E FIREBOX WILL EMIT SOME SMOKE AS IT CURES DURING THE FIRST HOUR OR SO OF RUNNING THIS IS QUITE NORMAL WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE WARNING ALWAYS MOVE THE AIR CONTROL TO THE OPEN POSITION TO THE RIGHT BEFORE OPENING THE FIRING DOOR CAUTION THIS APPLIANCE MUST NOT BE OPERATED WITH A CRACKED GLASS OPERATING HINTS FOR CLEAN BURNING AND BEST EFFICIENCY FUEL USE ONLY WOOD THAT HAS BEEN AIR DRIED IN A SHELTERED WELL VENTILATED STACK PREFERABLY FOR AT LEAST 12 MONTHS In all Clean Air Zones in New Zealand only wood may be used as fuel and it must have moisture content not greater than 25 measured on a dry weight basis e Do not burn driftwood treated painted wood or coloured paper as these can corrode the wood fire and flue CAUTION THE USE OF SOME TYPES OF PRESERVATIVE TREATED WOOD AS FUEL CAN BE HAZARDOUS e Add fuel reasonably often A large fuel load placed on a dying fire can drop combustion temperatures undesirably e Avoid large smouldering fires A small intense fire is more efficient e Move the heat control to maximum for a minute or so and turn off the air circulating fan if fitted before opening the door on a low burning fire This will clear away any fumes in the firebox e Always open the door SLOWLY and close and latch it shut securely again as soon as possible after re loading e When loading fuel place the pieces of wood in a front to back dir
14. STALLATION OF YOUR WOODFIRE BE CARRIED OUT BY A QUALIFIED SPECIALIST INSTALLER WARNING IF ANY ELECTRICAL WORK IS REQUIRED IT MUST BE CARRIED OUT BY A LICENSED ELECTRICIAN WARNING IN SOME REGIONS POWER POINTS ARE NOT PERMISSIBLE WITHIN THE FLOOR PROTECTOR AREA PLEASE CHECK WITH YOUR LOCAL AUTHORITY WARNING FOR APPLIANCES WITH WATER HEATING DEVICES DO NOT CONNECT TO AN UNVENTED HOT WATER SYSTEM INSTALL IN ACCORDANCE WITH AS 3500 4 1 OR NZS 4603 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE S WARNING IN NEW ZEALAND FAN amp WATER HEATING DEVICE CAN BE INSTALLED ONLY FOR RURAL APPLICATION EXCEPT INSERT MODEL MASPORT LE4000 PROVINCIAL WHICH IS TESTED WITH FAN amp FAN MUST BE INSTALLED BY A REGISTERED ELECTRICIAN INSERT MODEL 13000 WET WHICH IS TESTED WITH WATER HEATING DEVICE BOTH THESE MODELS ARE AUTHORIZED BY ECAN WARNING TO AVOID THE RISK OF ELECTRIC SHOCK OR CONTACT WITH MOVING PARTS ONLY THE MANUFACTURER AUTHORIZED SERVICE AGENTS OR SIMILARLY QUALIFIED PERSONS SHOULD REMOVE THE BOTTOM PANELS WHICH ALLOW ACCESS TO FANS WARNING THE APPLIANCE AND FLUE SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH AS NZS 2918 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES WARNING APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF AS NZS 4013 WHERE REQUIRED BY THE REGULATORY AUTHORITY I E THE APPLIANCE SHALL BE IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE M
15. appliance begins to spill smoke especially when a fire is started or when it dies down to coals Also it can starve fire from air needed resulting in poor performance pressure approximately combustion air enter into the room 6mm To prevent this extreme negative open a window to allow Over firing of the fire or Glowing red hot any part of fire at any time This is opposite of negative pressure effect Some modern heat pumps or heat recovery or ventilation systems can positively pressurize the house causing over firing control on the fire Try turning down heat output Try opening window to achieve pressure balance of the house If the problem persists contact Masport dealer or installer to diagnose the problem further l4 Cut Here Cut Kere Here 8 Other Comments GLEN DIMPLEX WARRANTY REGISTRATION WOOD amp MULTI FUEL FIRES RADIANT amp CONVECTION Thank you for purchasing a Masport Fire We ask you to complete the following information and return to the Glen Dimplex Warranty Registration Department on following address New Zealand P O Box 58473 Botany Manukau 2163 Auckland Australia Unit 1 21 Lionel Road Mount Waverley Victoria 3149 Mr Mrs Miss Ms Name Address Post Code 2 Telephone Fax Email Model Serial Number Retailer Purchase Date Price Installed By Date Installed We at Glen Dimplex st
16. asport Heating Service Agent The location of the Wood Fire must be advised to Glen Dimplex or its sales agents at the time of purchase or using warranty registration form Defects malfunctions or failures caused by incorrect installation poor installation normal wear and tear misuse neglect accidental damage or failure to follow operating instructions in the Owner s Manual including fuel selection product operation and maintenance instructions repairs or modifications by persons not authorised by Glen Dimplex use of parts not supplied by Glen Dimplex or damage or other events which have occurred since the product left the control of Glen Dimplex Direct indirect or consequential losses or special damages of any kind including costs of collection and delivery other than repair or replacement of products or components under this warranty where any goods are acquired or used for the purposes of a business How to obtain warranty service Completed Warranty registration form previous page needs to be mailed within 30 days of installation to your Glen Dimplex Warranty Registration Department Warranty Claims must be made at place of purchase Reasonable proof of purchase date is required to make a warranty claim You should keep your purchase receipt Warranty repair will be completed according to normal work practices of the service agent Make the faulty part s available to Glen Dimplex for inspection so that the validity of the
17. dling is well alight open the door slowly and add some larger pieces of wood When loading fuel place the pieces of wood in a front to back direction to ensure good air access and the cleanest possible burning Do not throw fuel pieces into the firebox as this may damage the top baffle and the insulating boards or firebricks Close and latch the door firmly Move the heat output control away from the maximum position only after the fire is well established A new wood fire should not be run at higher than half setting beyond the first 30 minutes until it has been used for a total of 8 hours Once fully run in we recommend running at full heat for up to one hour after lighting as this will minimize creosote build up in the flue The control can then be set wherever desired When reloading your fire make sure the air control is fully opened prior to opening the door This will reduce possibility of smoke spillage into the room Open the door slowly and reload the fire Leave the heat output or air slide control on high for a few minutes before adjusting the control to suit the heat level required After couple of initial burns leave 10 15 mm layer of ash at the bottom of the firebox In case of cast fireboxes roughly level up to top of the bottom ribs Ash acts as an insulator between steel cast bottom and the fire which helps in quick light up and air circulation within firebox NOTE THE SPECIAL HIGH TEMPERATURE PAINT ON TH
18. ds of the wood the wood is too wet Do not use this wood in your fire Large amounts of creosote could be deposited in your flue system creating potential conditions for a flue fire FAN WIRING DIAGRAMS SWITCH NO 503674 INSULATORS NO 591321 CONNECTORS INSULATORS NO 591321 CONNECTORS HIGH SPEED BLE BLUE GREENAYELLOW U EARTH POST LOOM 3 PIN NO 588068 LOOM FAN SWITCH NO 593291 FAN NO 593289 FAN WIRING DIAGRAM TWO SPEED WOOD FIRES INBUILT MODELS LE7000 19000 15000 593292 TER CT EDEN CONNECT TO POWER SUPPLY PERMANENTLY INSULATORS NO 591321 REFER INSTALLATION CONNECTORS INSULATORS NO 591321 FAN GUIDE FOR DETAILS CONNECTORS EARTH POST LOOM 3 PIN NO 588068 LOOM FAN SWITCH NO 593291 FAN NO 593289 FAN WIRING DIAGRAM LOW SPEED LE4000 INSERT INBUILT FIRE 593277 B i LOOM 3 PIN e IE SWITCH 3 z 3 588068 3 EARTH POST s 3 EARTH LEAD EARTH POST 594785 ON PEDESTAL SWITCH 3 X INSULATOR N 503674 591321 T GREEN YELLOW EARTH n BROWN BLUE COMMON MOTOR FAN RED co BROWN HIGH SPEED BLACK Go BAK LOW SPEED 2 X INSULATOR 591321 n meum DES ze os en ar Ba FAN LOOM FAN 594788 593293 FAN WIRING DIAGRAM W F FREESTANDING 2011 Australian Models On ly
19. ection to ensure good air access and the cleanest possible burning This will give you the overall emission and room heating efficiency that the fire was designed and tested to achieve except Atlanta Bay NZ model which was emission tested with fuel loading from side to side e Load fuel carefully to avoid damage to the insulating boards firebricks or top baffle e f smoke wafts into the room from a fully established fire while the door is open first check that make up air can flow freely into the room to replace the air passing up the flue Make up air is the replacement air used by fire for combustion which needs to come into the room from external sources See box below e Then check that the flue is not obstructed in any way particularly by the rain cap being too close to the end of the flue See the flue cleaning requirements in the Maintenance section page 9 If these checks do not uncover the fault add an extra length of flue bracing it if necessary to counteract the down draught effects caused by roof shape nearby buildings hills or trees e Switch off the circulating fan if fitted when the fire is burning at low heat outputs This does not apply to LE4000 Provincial insert as it is permanently connected to main power supply e After a season or two adjust the door to eliminate any minor leakage See MAINTENANCE Adjusting the Door Latch section on page 8 REMEMBER FOR THE FIRE TO DRAW PROPERLY AIR MUST B
20. fit the metal retaining channel over the top edges of these pairs of bricks or boards to hold them in line The wider leg of the channel goes next to the fire box wall Some models will have brick and baffle layout diagram on a separate sheet 10 FAN MAINTENANCE Only the manufacturer its service agent or a similarly qualified person should remove the ash shelf of the LE4000 Provincial LE5000 Provincial LE7000 Provincial or bottom fascia panel of the 19000 and 15000 to carry out fan installation servicing and maintenance The fan should need little attention other than occasionally perhaps once a year removing it to clean dust and lint from the impeller First unplug the mains lead from the power point Fans on in built fires can be accessed by lifting off the ash shelf or by removing the bottom panel of the fascia Fans on free standing fires are reached by removing the rear of the pedestal On free standing models with internally switched fans first gently ease off the speed control knob taking care to pull it off squarely Remove the four screws two on the Grandview which hold the fan box in position If the fan on the free stander is internally switched move it slightly away from the switch end and withdraw it completely Some fans simply stand on rubber bushes fitted over fixed posts These simply lift away vertically from the post remove any shipping nuts first but do not replace them Clean the impeller blades carefully by
21. nd adherence to the following instructions will ensure satisfactory performance WARNING MAKE SURE THE MINIMUM HEATER TO WALL DISTANCES SHOWN ON THE SPECIFICATION SHEET ARE ALWAYS MAINTAINED BETWEEN THE HEATER AND ANY HEAT SENSITIVE ITEMS WALLS FURNITURE DRAPES ETC WARNING DO NOT STORE FUEL WITHIN THE HEATER INSTALLATION CLEARANCES WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS OR PLACE THESE IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING WARNING THIS APPLIANCE MUST NOT BE USED AS AN OPEN FIRE WARNING WHEN FITTED WITH A WATER HEATING BOOSTER THIS APPLIANCE MUST NOT BE CONNECTED TO AN UNVENTED HOT WATER SYSTEM THIS APPLIANCE MUST BE INSTALLED WITH AN OPEN VENT THERE MUST BE NO SHUT OFF OR NON RETURN VALVES IN THE PIPING SYSTEM REFER TO WATER PIPE INSTALLATION INSTRUCTIONS LIGHTING UP CAUTION THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS 1 2 oOo Slide the heat output control fully to the hot position Crumple up several double sheets of newspaper and place them in the centre of the firebox Build a pyramid of thin dry kindling wood on the paper with some heavier pieces on top Light the paper at the bottom and leave the door slightly ajar until the kindling has caught then latch the door shut firmly Gradually build up the fire by adding 2 or 3 small logs at a time whilst ensuring the heat output control is still in When the kin
22. of multi fuel fires an ash pit door as it will result in over firing over heating and subsequent damage to the fire box e Fires can be caused accidentally by wrapping seemingly cold ashes in paper It is much safer to place ashes outside in a metal container with a close fitting lid If a fire is burning up inside the flue slide the heat output control to the low heat position to the left and call the Fire Service DO NOT OPEN THE WOODFIRE DOOR IN THIS SITUATION e f you have had a flue fire inspect your flue for damage before lighting another fire e Do not modify your wood fire in any way without obtaining written permission from the Manufacturer CAUTION IF THE GLASS IS CRACKED OR BROKEN THIS APPLIANCE MUST NOT BE USED THE GLASS SHOULD BE REPLACED ONLY WITH A GENUINE CERAMIC GLASS REPLACEMENT PART AVAILABLE FROM YOUR GLEN DIMPLEX DEALER MAINTENANCE ASH REMOVAL This should be necessary only very occasionally Simply shovel out any excess always leaving a bed of ash to the tops of the ribs on the bottom of the firebox Place the removed ashes in a noncombustible container with a tightly fitting lid and move the container outdoors immediately to a place clear of combustible materials CLEANING THE GLASS A good hot fire will burn away any deposits left from a long slow burn A dampened newspaper with ash or a non caustic oven cleaner can be used to clean the glass CLEANING THE CABINET OR FASCIA A soft rag dampened
23. rive to provide you with quality products and have continuous product development program To help achieve our objectives to our mutual benefit we would welcome your feedback on the following questionnaire Question Please tick appropriate remark 1 General presentation of Product Excellent Good Ok Needs to Improve 2 Styling and Looks Excellent Good Ok Needs to Improve 3 Packaging Excellent Good Ok Needs to Improve 4 Is documentation easy to follow Excellent Good Ok Needs to Improve and informative 5 Fixtures 8 Fittings Loose parts In order Items missing Needs to Improve 6 Do you currently own Masport or Yes No Which Dimplex product 7 Why did you decide on Masport Knew this brand Suggested by Friend tick one or more options Dealer Recommended o Better Price Performance Features Privacy Act Notice the owner named on the Warranty Registration consents and agrees that Glen Dimplex may retain and use the information in this warranty card including details about the owner for marketing and development purposes The owner also agrees that Glen Dimplex may also share purposes with intended recipients of such information In accordance with the New Zealand Privacy Act 1993 and the Australian Privacy Act 1988
24. t each end and that it is pushed right to the back until the front corners drop behind the small retainer ribs on the shelves Re fit the secondary air tube in place Note Some fires are equipped with steel baffles Warning Ensure that secondary air tubes and baffle are correctly repositioned and secured with the correct fasteners prior to relighting the appliance If you are unsure consult the manufacturer or authorized service agent FIREBOX LINERS While the insulating boards or firebricks are durable they will eventually require replacement A cracked liner does not require replacing unless it will no longer stay in position in the firebox All Masport models have either fire bricks or insulating board to line the firebox Some models have insulating boards already fixed in position at the factory In some models two of the bricks or boards fit across the back of the firebox wall and the others fit against the side walls No force should be required to fit them and they can be removed if desired for flue cleaning However they MUST be in place and in good condition before lighting the fire Each brick or board is fitted in the same way Angle it into position with its top corner behind the upper retaining lug and then swing it until it is parallel to the wall with its bottom corner behind the lower retaining lug Lower the brick or board into position In some models there are two boards at the rear and at each side In that case
25. the owner shall have the right to request the correction of as well as inspect all personal information held by Glen Dimplex on that owner Please cut and mail this completed form within 30 days of installation to your rc Glen Dimplex Warranty Registration Department at the above address Oo 15 16 WARRANTY FOR MASPORT WOOD amp MULTI FUEL FIRES Radiant amp Convection This warranty is provided in New Zealand by Glen Dimplex Australasia Ltd and in Australia by Glen Dimplex Australia Pty Ltd together referred as Glen Dimplex This warranty is provided to the first domestic purchaser of a Masport wood or multi fuel fire radiant or convection It applies from the date of purchase from or through an authorized Masport Fire Distributor in relation to each product or component for the period below TYPE OF PART WARRANTY In Years PARTS LABOUR WOOD FIRE FIRE BOX CAST IRON 10 5 WOOD FIRE FIRE BOX STEEL 10 5 MULTI FUEL FIRE BOX CAST IRON 5 2 5 MULTI FUEL FIRE BOX STEEL 5 2 5 DOOR GLASS 8 SEAL 1 FIREBRICKS BOARDS amp RETAINERS 1 SECONDARY AIR TUBES 1 BAFFLE COMPONENTS 1 WATER BOOSTER 1 GLEN DIMPLEX FLUE SYSTEMS 1 FANS amp ELECTRICAL COMPONENTS 1 a lol aj jaj During the warranty period Glen Dimplex will repair or replace at its option any Masport Wood Fire which is found to be defective in materials or workmanship Repairs will be carried out by an approved Masport Heating Service Agent What is